66
2018 Shimadzu Electronic Balances General Catalog C054-E032R

C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

Embed Size (px)

Citation preview

Page 1: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

2018Shimadzu Electronic BalancesGeneral Catalog

C054-E032R

Page 2: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

1918

1960

1970

1930

1995

2004

2003

2010

2011

1980

2000

2002

2007

1918

1960

1970

1918 Top-Pan Torsion Balance

1875 Establishment of SHIMADZU CORPORATION

1930 Chemical Balance1930

1958 Type L Direct-Reading Balance

1995 1995 EL Series Load Cells

2004 MOC-120HMoisture Analyzer,world's first to include aUniBloc sensor

2003 AU Series Analytical Balances,world's first to include a UniBloc sensor

2010

2011

AT SeriesAnalytical Balancedesigned foreasy operability

2007 TX/TXB Series General-Purpose Balancesdesigned for easy operability

MOC63u Low-Cost Moisture Analyzer with UniBloc sensor

BL SeriesSimple Balances

BW/BX SeriesGeneral-Purpose Balances

1970

D-1003Digital Balance

1981

AEL-160AnalyticalBalance

1985

AEL-200Analytical Balance

1978

ED Series

19801987

UniBloc integratedmass sensordeveloped

2000

BW/BX-K Series Medium-SizePrecision Platform Balances,the first to include a UniBloc sensor

UW/UX SeriesGeneral-PurposeBalance with UniBloc

2002

AW/AX/AY SeriesAnalytical Balances

LDS SeriesPlatform Balances

Introduction of UniBloc

2007 UniBloc maturation period

20162016 AP Series Analytical Balances

20182018 100th year of making balances!! Please continue choosing Shimadzu balances.

1875

Providing Balances and Scales for 100 YearsSupporting manufacturing in the future, utilizing 100 years of experience and knowledgeShimadzu began manufacturing balances in 1918. Throughout this 100-year history, we have been at the forefront of providing precision,

quality solutions for the most challenging R&D and QA/QC requirements. Our steadfast customer-focused commitment and unwavering dedication

to technical excellence are both hallmarks of our history and the principles that guide us into the future.

Page 3: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

P 50 - Printer

P 51 - Specific Gravity Analyzer

P 56 - Animal Balances

P 58 - LabSolutions Balance

P 60 - Optional Accessories

P 62 - Physical Dimensions

SHIMADZUELECTRONIC BALANCES

A Tradition of Weighing Expertise

P 08 -

P 10 - Product Lineup

P 14 - AP Series

P 26 - Static Remover (Ionizer)

P 28 - Analytical Balances

P 36 - Electronic Balances

P 40 - Top-Loading Balances

P 41 - Portable Electronic Balances

P 42 - Precision Platform Balances

P 43 - Moisture Analyzer

Contents

P 06 - Diverse Range of Functions

P 04 - UniBloc

Excellent Performance forMultiple Industries

Established in 1875 in Kyoto, Japan, Shimadzu Corporation is one of the pioneers of scientific precision instruments.

Top-pan and torsion balance production started in 1918,and equal-beam analytical balances were introduced in 1925. Since their release, the continuous improvement of Shimadzu balances has contributed to research and development across all industries.

Around the turn of the 20th century, precision weighing was a time-consuming practice performed only by experienced operators. Placing the sample and small masses on pans hung from a beam scale with a moving indicator was a tedious process. Shimadzu strove continuously to streamline weighing procedures. The introduction of the direct reading analytical balance (patented in Japan in 1948) signified a new era in weighing technology. In the Type L balance, the sensitive mass-loading work was replaced by convenient dial operations. This reduced weighing time by 66% and, subsequently, reduced demand for conventional balances.

Shimadzu then added the top-loading direct reading balance with Roberval’s mechanism in 1959. Until recently many of these instruments were still utilized in modern laboratories.Shimadzu continued to pioneer new technologies, releasing its first electronic balance in 1971—the Digibalance. This release marked a

milestone in precision weighing, introducing simplicity and ease of use to analytical weighing.

Six years later (1977), the application of microprocessors in electronic balances further enhanced weighing performance. The compact ED Series provided substantial improvements in sensitivity, resolution, and stability.

More recently, Shimadzu has introduced user-friendly instruments and features to the market, such as :temperature-based fully-automatic calibration in 1985,the first one-piece force cell (OPF, later renamed UniBloc) in 1989, the high-sensitivity AEM-5200 Micro Balance in 1993,and the unique WindowsDirect feature perfectly suited for the computerized laboratory of the 21st Century.

Its most recent achievement is the AP Series, advanced performance balances featuring UniBloc and a high response speed, and which are applicable for a wide range of applications.

Moving forward, Shimadzu is committed to providing innovative products for the analytical marketplace.

Page 4: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

Test results of impact resistance test withtop-loading balances (Minimum display: 10 mg)

Shimadzu balances advance to the UniBloc generation

The results of this impact resistance test prove Shimadzu UW/UX series balances with UniBloc technologyare the toughest. Put Shimadzu balances in your lab and experience UniBloc power.

Free-falling the weight (3 kg) at 4 sec intervals.(Weight was dropped from a height of 5mm for the first 100,000 impacts.After the first 100,000 tests, it was dropped from a height of 10 mm.)

No.1

START Loading:100,000 times

Force springbroke after22000 impacts

Balance wasnot functionalafter 10000 impacts

Additional Loading:10,000 times

2nd fulcrum springbroke after1400 impacts

Clear

Clear

Height: 5 mm Heiight: 10 mmmShimadzu UW6200H

A Top-loading balance

ElectromagneticsystemOne aluminumtype structureWirecut

Electromagnetic systemOne aluminumtype structureWirecut

B Top-loading balanceElectromagnetic systemAssembly typePress

C Top-loading balanceOthersOne aluminumtype structureWirecut

Test conditions

Impact resistance test for four balances

made by typical manufacturers.

(Shimadzu internal test)

Free-fall

OUT/IN

IN/OUT

ON/OFF

Top-loading balance

weight(app 3kg)

Electromagneticvalve

PLCcontrol

Airresource

Air cy

lind

er

Air cy

lind

er

4

U n i B l o c P o w e r !

Page 5: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

5

UniBloc technology leads toa new world of measurement

pan

1st lever

1st force spring

1st fulcrum spring2nd force spring

2nd fulcrum spring

parallel

set

on

th

e b

ase

2ndlever

to coil

Number of parts: 1 pcVolume : app. 1/10 of conventional one

Conventionalmeasurement unitIt consists of app.70pcs with variousmaterials

Reliability

Stability Response

Keywords ofUniBloc features

5

pan

1st lever

1st force spring

1st fulcrum spring2nd force spring

2nd fulcrum springp

parallel

set

on

th

e b

ase

2ndlever

to coil

Number of parts: 1 pcVolume : app. 1/10 of

conventional one

Conventionalmeasurement unitIt consists of app.70pcs with variousmaterials

R llRelRelRelRelRelRelRelRelRelReRRelRelReliabiabiabiabiabiabiabiabiabiabiabiabiabbiabia iliiliiliiliiliiliiliiililiililitytytytytytytytytyyyyy

aaaaaabbbibilbilbilbilbilliititityitytyityityityityityyityty ReResRResResponponponponsse

Keywords ofK d fniBloc features

U n i B l o c f a m i l y o f b a l a n c e s

MOC63u UW/UX seriesBX-K/BW-K series ATX/ATY seriesTW/TX series AU series

Amount

1/70Volume

1/10

AP series

Shimadzu introduced one-piece force cell technology for precision balances in 1989. Today’s UniBloc is

created by high-precision electric discharge wire processing applied to a block of aluminum alloy, and

replaces the conventional electro-magnetic balance sensor assembly. UniBloc’s compact, uniform structure

ensures stable temperature characteristics, excellent response time and stable corner-load performance.

In addition, the UniBloc design permits a consistency of production that assures reliability and a long

operational life.

The updated UniBloc technology expands the UniBloc balance lineup, which now ranges from semi-micro

with a minimum display of 0.01 mg to precision platform balances up to 52 kg in capacity.

One-piece force cell patented in USA in 1989, No. 4799561, in China in 1991, No. 12729, in Japan in 1995, No. 1905686

Page 6: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

UniBloc is a completely new mass sensor, developed by Shimadzu through further modification of its OPF

aluminum block mass sensor, a world's first in development. UniBloc is created by high-precision electric

discharge wire processing applied to a block of aluminum alloy in order to replace the conventional sensor

block assembly. As such, it uses no springs or screws. This uniform structure dramatically improves response and

temperature characteristics, and the simple yet compact design enhances impact resistance. Balances equipped

with UniBloc provide highly reliable mass measurement even with prolonged use.

Next-Generation Mass Sensor: UniBloc

The balance has built-in motor-driven calibration weights.

Sensitivity can be calibrated whenever needed with a single

key press.

b Internal Calibration

The balance has built-in calibration weights. Sensitivity is

calibrated with a simple lever operation. Sensitivity can be

calibrated easily, whenever needed.

c Single-Lever CAL

The balance can also run on dry cell

batteries, enabling use outdoors where no

power is available.

. Dry Battery Operation

Preset the upper and lower limit values to display pass, high

or low, depending on the sample weight.

u Checkweighing

Proper weight, high, low and other pass/fail judgments

can be indicated by a buzzer, or output externally as a

contact signal. (Optional comparator buzzer or relay

output interface required.)

1 Comparator Output

Naturally, weight measurements can be

taken even if the work site is dark, and

prolonged use at normal work sites will not

tire your eyes.

/ Backlight

Keys exclusively for menu

operations are arranged

separately from the

measurement keys. Menus can

be operated intuitively using

the cross-shaped key layout.

Easy-to-Operate Key Layout

Constantsensitivity

error

The perfect self calibration (PSC) function keeps thesensitivity error within a constant range at all times.

Room temperature changes

Electronic balances are precision instruments very susceptible to changes in

room temperature. Sensitivity must be calibrated every time the balance is used

since changes in room temperature influence mass measurement values, which

are not supposed to change. The balance detects changes in room temperature

that affect sensitivity, and automatically starts calibration using built-in

weights. As a result, sensitivity errors are always kept within a constant range.

This allows the operator

to concentrate on

measurement tasks

without having to worry

about sensitivity

calibration.

f Perfect Self CalibrationEasy Setting

Menu Operation Key The balance starts calibration using built-in weights at preset times. If you set

calibration times before important measurements (e.g. before starting work in

the morning, or during the lunch or evening break), the balance will

automatically start calibration when the preset time is reached. This lets you

take stable, reliable

measurements without

worrying about

sensitivity calibration.

a Clock-CAL

HighLevel

Functionality

01

Durability

02

ConvenientFunctions

03

Shimadzu Balances Offer a Diverse Range of Functions

6

0

Ro

om

tem

per

atu

reSe

nsi

tivi

tyer

ror

AM8:00 PM0:30 PM5:00

Sensitivity calibrated automatically at thetimes determined by Clock-CAL

During operation, if you want to make the display

slightly more stable, or alternatively, want to improve

the response speed, you can make one-touch

adjustments without interrupting measurement. A

special indicator is provided that instantly shows the

adjustment status.

Page 7: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

With the optional printer connected, data

can be recorded with date and time

stamps. Calibration reports can also be

date- and time-stamped, which is ideal for

establishing the measurement

management and traceability required by

GLP, GMP and ISO 9001.

d Built-in ClockSimply connect an optional printer to automatically

print out which balance was calibrated when, and

the calibration results. Absolutely no troublesome

settings are required. Furthermore, the current date

and time can be printed anytime during

measurement.

i ISO Calibration Report

Connecting with LabSolutions lets you save data from

balances, HPLC and other analysis instruments to a

database, and create reports automatically. Uniform

data management means no transcription errors, and is

perfect for security.

LabSolutions Balance

A built-in piece counting function enables balances to be used as

parts counters (piece scales).

OPiece Counting

A specific gravity calculation function based on

the immersion method is built in.

Just attach the optional Specific Gravity

Measurement Kit to use a balance as a specific

gravity meter.

PSpecific Gravity Measurement

The weight of mice, rats, rabbits, and

other small animals can be measured.

Stable measurements are obtained even if

the animal moves.

5 Built-in Animal Measurement Mode

Results can be displayed in carats when

measuring precious stones.

Carat Measurement

ISOGLPGMP

04

Network

05

Applications

06

7

(AUW Series Printout Sample)

Date and time areautomatically printed

Balance modelBalance serial numberUser ID number

Value of the weight used

Balance measurementbefore calibration(adjustment)

Balance measurementafter calibration(adjustment)

The calibratorsigns here.

(AUW Series Printout Sampl(AUW SS i P i t t S l

om

m

n

m

d is

To Establish an Internal AnalysisData Management System

Page 8: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

Excellent Performance for Multiple Industries

8

Chemical

Medical Products

Food

Cosmetics

• Weigh liquids and powders in development departments

• Measure specific gravity and moisture ratio of resin pellets, rubber, etc.

• Input mass values via connection to a titration system for quality management

• Measure mass and moisture ratio of dyes, pigments, and inks

• Measure and control materials accumulated on filters

• Control moisture ratio levels during catalyst production

• Check weights when receiving raw materials

• Confirm the net weight of final products

• Measure the moisture ratio and control the quality of raw materials and products

• Weigh trace quantities of additives

• Weigh raw materials during formulation

• Measure weight changes in creams and compresses at specified intervals

• Control the quality of product containers and cases

• Measure the moisture ratio of hair, etc.

• Control pharmaceutical usage quantities by measuring weight before and after use

• Weigh raw materials

• Confirm the weight of stents and other miniature medical devices

• Measure the moisture ratio and control the quality of raw materials and products

• Measure weight changes during animal experiments

• Measure drugs during drug manufacturing processes

Page 9: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

9

Metals/Precious Metals

Automotive

Electronics

Academia

• Count the number of very small products

• Check the weight of coated steel sheets/plates after polishing

• Control the moisture ratio and specific gravity of iron and steel raw materials

• Measure trace quantities machined from metals, etc.

• Measure the specific gravity of rare metals and compare it to theoretical values

• Control the amount of wear on metal materials

• Weigh items when purchasing precious metals or bullion

• Check weights when manufacturing electronic circuit boards

• Measure tiny semiconductor parts

• Check for missing items in product packages based on weight

• Control the quantity of plastics used in LED lenses

• Measure exhaust gas accumulation on ceramic parts and filters

• Measure electrolyte injection quantities on lithium-ion battery production lines

• Measure moisture ratio in sheet materials

• Control contamination remaining on machinery parts

• Use for training students

• Manage reagent use by weight, in combination with a chemical substances management system

• Use in lectures to explain basic principles and theory

Page 10: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

10

Product LineupProd

uct Lin

eup

0.01mg

0.1mg

0.001g(1mg)

0.01g~(10mg)

UW820H UX820H (820g/0.001g)

UW620H UX620H (620g/0.001g)

UW1020HUX1020H(1020g/0.001g)

UW420H UX420H (420g/0.001g)

TW423L TX423L(420g/0.001g)

TW323L TX323L (320g/0.001g)

BL-320H(320g/0.001g)

UW220H UX220H(220g/0.001g)

TW223L TX223L (220g/0.001g)

BL-220H(220g/0.001g)

AUX320 AUW320 (320g/0.1mg)

AUW220 AUX220 AUY220 (220g/0.1mg)

ATX224 ATY224 (220g/0.1mg)

AUW120 AUX120 AUY120 (120g/0.1mg)

ATX124 ATY124 (120g/0.1mg)

TWC623L TXC623L (620ct/0.001ct)

ATX84(82g/0.1mg)

ATY64(62g/0.1mg)

AP125WD(120g/0.1mg)(52g/0.01mg) AUW220D(220g/0.1mg)(82g/0.01mg)

AUW120D(120g/0.1mg)(42g/0.01mg)

UW4200H UX4200H (4200g/0.01g)

TX4202L(4200g/0.01g)

TX3202L(3200g/0.01g)

BL-3200H(3200g/0.01g)

UW2200H UX2200H (2200g/0.01g)

TX2202L(2200g/0.01g)

BL-2200H(2200g/0.01g)

UW820S UX820S (820g/0.01g)

TXB622L(620g/0.01g)

BL-620S(620g/0.01g)

ELB600(600g/0.05g)

UW420S UX420S (420g/0.01g)

TXB422L(420g/0.01g)

BL-320S(320g/0.01g)

ELB300(300g/0.01g)

TXB222L(220g/0.01g)

ELB200(200g/0.01g)

ELB120(120g/0.01g)

~100g 100g~ 300g~ 500g~ 1kg~ 3kg~

AP135W(135g/0.01mg)

AP225WD(220g/0.1mg)(102g/0.01mg)

ATX324 ATY324 (320g/0.1mg)

AP324W AP324X AP324Y (320g/0.1mg)

AUW/AUX/AUY Series ATX/ATY SeriesAP Series (0.1mg model)

AUW-D SeriesAP Series (0.01mg model)

UW/UX Series

TW-N/TX-N/TXB Series

AP124W AP124X AP124Y (120g/0.1mg)

AP224W AP224X AP224Y (220g/0.1mg)

Page 11: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

11

BL-320S(320 g/0.01 g)

ELB300(300 g/0.01 g)

UW420HV(420 g/0.01 g)

AUW220D(220 g/0.1 mg)(82 g/0.01 mg)

How to use

capacitymodelname

minimumdisplay

Dual range

Internal Calibrationmodel is in blue

Prod

uct Lin

eup

0.01g(10mg)

0.1g(100mg)

1g~ BW52KS BX52KS (52kg/1g)

BW32KS

BX32KS (32kg/1g)

ELB12K(12kg/1g)

TXB6200L(6200g/1g)

ELB6000S(6000g/1g)

BW32KHBX32KH (32kg/0.1g)

BW22KH BX22KH (22kg/0.1g)

BW12KH BX12KH (12kg/0.1g)

UW8200S UX8200S (8200g/0.1g)

TXB6201L(6200g/0.1g)

UW6200H UX6200H (6200g/0.01g)

5kg~ 10kg~ 30kg~ 50kg~

UW/UX Series

BW-K/BX-K Series

TXB Series ELB Series

~100g 100g~ 300g~ 500g~ 1kg~ 3kg~

0.1g~ UW4200SUX4200S (4200g/0.1g)

TXB4201L(4200g/0.1g)

BL-3200S(3200g/0.1g)

ELB3000(3000g/0.1g)

TXB2201L(2200g/0.1g)

ELB2000(2000g/0.1g)

ELB1200(1200g/0.1g)

ELB600S(600g/0.1g)

ELB Series

BL Series

Page 12: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

12

Product LineupProd

uct Lin

eup

AUW-DAUW

△*

ATXATYAUX

AUY

AP-Y

AP-X

○ :Standard function

△ :Option

*Requires optional I/O-RS conversion cable or interface IFB-102A.

(AUW only)

(ATX only)

AP-WDAP-W

UniBloc

Perfect Self Calibration

Clock-CAL

Internal Calibration

Single-Lever CAL

Built-in Clock

ISO Calibration Report

Menu Operation Key

Easy Setting

Backlight

Organic EL Display

Balance Keys

Built-in RS-232C Interface

Built-in USB Interface

Analog Bar Graphic Display

Checkweighing

Comparator Output

Piece Counting

Carat Measurement

Specific Gravity Measurement

Dry Battery Operation

Standard Below-weight Hook

Built-in Animal Measurement Mode

Formulation Mode

Internal Timer Output

fabcdi

LM

gu1O P

564

.

BalanceKeys

Page 13: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

13

Prod

uct Lin

eup

BW-KBX-K

MOC63uMOC-120H

TWTXUW

UX

TXB

BL

△*

ELB

△*

(TW-N only)

(BW-K only)

(MOC63u only)

UW-V

Page 14: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

*1 Al l models : USB-B type connector as standard AP-W Ser ies: USB-A type and B type as standard

H i g h S p e e dThe response time for trace measurements (from 1 mg) is reduced to about 2 seconds.This significantly improves weighing efficiency.

S t r e s s F r e eThe STABLO-AP ionizer can be mounted. This eliminates the influence of static electricity, achieving reliable measurements in a simpler procedure.

Fo r H P LCFunctions are included for the preparation of buffer solutions used in HPLC.As a result, the operation can be performed accurately and easily, even by non-specialists.

S a v e Yo u r O p e r a t i o nEquipped with USB as standard*1. Includes many diverse functions to support users.

Fo r R e g u l a t i o nInterlocking with LabSolutions Balance enables compliance with a variety of regulations for measurement data integrity, including ISO 17025 for testing laboratories, ISO 9001 and ISO 14001 for the manufacturing industry, and GLP/GMP and the United States Pharmacopeia (USP) for the pharmaceutical industry.

A P S e r i e sA d v a n c e d P e r f o r m a n c e U n i B l o c B a l a n c e s

P ro v i d e s H i g h - s p e e d R e s p o n s e a n d H i g h S t a b i l i t y

A N e w S t a g e i n A n a l y t i c a l B a l a n c e P e r f o r m a n c e

14

AP Series | 0.01 mg to 0.1 mg | Analytical BalancesAP Series 

| 

0.01 mg

to 0.1 m

g | 

An

alytical Balan

ces

Page 15: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

* AP224W with optional ionizer

Watch the AP overview video on our website.

http://www.shimadzu.com/an/balance/analytical/ap.html

1

An

alytical Balan

ces

15

Page 16: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

AP Series 

| 

0.01 mg

to 0.1 m

g | 

An

alytical Balan

ces

AP Series | 0.01 mg to 0.1 mg | Analytical Balances

High Speed Fast measurement significantly

improves operational efficiency.

Fast Response with UniBloc AP Technology

Shimadzu analytical balances boast a one-piece UniBloc weighing sensor, which is now

even more advanced.

The response time is reduced to about 1/5 the time of previous models.

The improved UniBloc sensor offers a response time of just 2 seconds, an improvement

from 10 seconds with the previous model.

Response During Trace Measurements with the 0.01 mg Model(Equivalent to 1 mg / With Conditions Set by Shimadzu)

AP225WD (New model)

Indi

catio

n [m

g]

AP225WD approx. 2 sec.

10 2 3 4 5 6 7 8 9 10 11 120.0

0.2

0.4

0.6

0.8

1.0

1.2

Time [sec.]

AUW220D (Previous model)

AUW220D approx. 10 sec.

Response During Trace Measurements with the 0.1 mg Model(Equivalent to 1 mg / With Conditions Set by Shimadzu)

AP324W (New model)

0 1 2 3 4 5 6 7 8 9 10 11 12

AUX320 approx. 7 sec.AP324W approx. 1.5 sec.

Indi

catio

n [m

g]

0.0

0.2

0.4

0.6

0.8

1.0

1.2

Time [sec.]

AUX320 (Previous model)

Model

0.01 mg

0.1 mg

AP Series

2 sec.

1.5 sec.

Previous Model

10 sec.

7 sec.

* AP135W

Advanced Digital Control for Fast, Reliable Weighing

The improved measuring feel provides more comfortable use.

AP-i System (intelligent - Advanced Processing System)

Detects variations in weight

Digital control

High-speed control!Calculates weight signal!

Weight signal + Noise +External disturbances

Smoothing

Cuts noise andexternal disturbances!

Weight signal

Measuring feel has been significantly improved by using the advanced digital control technology and smoothing technology.

AP-i system provides reliable weighing even in an environment with significant external disturbances. This promises to increase the

efficiency of your measurement operations.

16

Page 17: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

Stress Free A variety of accessories and options suitable

for semi-micro measurements

1

An

alytical Balan

ces

The multi stand can be used freely and easi ly.(0.01 mg model only, equipped as standard)

With weighing paper, for example, if the tare is larger than the pan diameter, measurements can be simplified by attaching the special multi stand.

Measuring weights with a pipette can be simplified by placing a micro tube upright in the sample holder in the special multi stand.

Long rod-shaped samples can be measured in a stable state by placing them in the slot in the special multi stand.

The internal windbreak plate suppresses the influence of convection and airflow within the weighing chamber, improving the stability and response of measurement values.

Built- in High-Performance Ionizer (Optional)

The ionizer eliminates influence of static electricity in 1/10the time of previous models.Note: Example of typical static electricity removal time (±1000 V ±100 V) 1 sec. for STABLO-AP and 10 sec. for STABLO-EX

AC Method with Excellent Ion Polarity BalanceMount the STABLO-AP in the balance and use it as a built-in model

Comparison of Neutralization Speed (Representative Values) STABLO-APPrevious model

Stat

ic C

har

ge

Vo

ltag

e (V

)

1000

900

800

700

600

500

400

300

200

100

0

Faster Neutralization

10 timesQuicker

0 2 4 6 8 10 12 14 16 18 20

Neutralization Time (sec.)Measurement Conditions• Time from ±1000 V to ±100 V• For this evaluation, a 150 × 150 mm charged plate monitor (CPM, 20pF) was used.

• Distance between CPM and ionizer: 100 mm

17

Page 18: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

18

Buffer Solut ion Preparat ion Mode (AP-W Series only)

•Recipes for 13 commonly used buffer solutions are included as standard Preparation recipes for commonly used buffer solutions are provided as standard.

e.g. disodium phosphate, sodium acid citrate

•New buffer solution recipes can be registeredIf a buffer solution is not registered by default, it can be newly registered.

•Instructions are shown on the displayThe target weighing value is shown on the display and analog bar in order to compare the target with the current weight. Manual calculation is

not needed.

•Record functionRecord output with date, time and operator name.

The pH level of mobile phase (eluent) solutions used in liquid chromatographs is adjusted to improve separation of components and extend the

life of columns. This pH adjustment process is performed using a buffer solution.  Currently, the most common method is using a pH meter to

measure the pH as the solution is prepared; however, this process requires considerable time and effort, which can cause operational bottlenecks.

An alternative method does not require a pH meter. It involves preparing solutions by weighing fixed theoretically calculated quantities of an acid

and base.

AP series supports weighing these acids and bases. If the type and quantity of the buffer solution are specified, the balance displays the type and

quantity of sample that should be weighed. Then the buffer solution can be prepared easily by adding water to the specified quantity of sample

weighed accordingly.

Preparation example: When weighing and preparing 50 mM of di-sodium hydrogen phosphate, 2-hydrate and 50 mM of sodium

dihydrogenphosphate, 2-hydrate in order to prepare 3 L of 100 mM phosphoric acid (sodium) buffer solution at pH=2.1:

Example of preparation by AP series

Select the buffersolution mode.

Specify the typeand quantity.

Displays the nameand quantity of sample.

Prepare as instructedon screen.

Complete buffer solution

* Results can be printed with date/time and user ID.

Number

1

2

3

4

5

6

7

8

9

10

11

12

13

Buffer solution preparation list

100mM

10mM

50mM

100mM

10mM

20mM

20mM

10mM

10mM

20mM

100mM

100mM

100mM

phosphoric acid (sodium)

phosphoric acid (sodium)

phosphoric acid (sodium)

phosphoric acid (sodium)

phosphoric acid (sodium)

citric acid (sodium)

citric acid (sodium)

tartaric acid (sodium)

tartaric acid (sodium)

acetic acid (ethanolamine)

acetic acid (sodium)

boric acid (potassium)

boric acid (sodium)

pH = 2.1

pH = 2.6

pH = 2.8

pH = 6.8

pH = 6.9

pH = 3.1

pH = 4.6

pH = 2.9

pH = 4.2

pH = 9.6

pH = 4.7

pH = 9.1

pH = 9.1

AP Series | 0.01 mg to 0.1 mg | Analytical BalancesAP Series 

| 

0.01 mg

to 0.1 m

g | 

An

alytical Balan

ces

For HPLC For Users of HPLC Systems

Page 19: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

1

An

alytical Balan

ces

19

Sample Preparat ion (AP-W Series only)

When preparing a standard solution from a particular component, the standard powder for this component will be a hydrochloride or a hydrate.

Preparing a standard solution of the target component at a desired requires difficult calculations prior to weighing it. With the AP series,

however, the required weight value is automatically calculated, so it can be weighed without performing manual calculations.

Example of preparation by AP series

Weigh 25 mg Amitriptyline to make a standard solution

Standard sample of Amitriptyline is Amitriptyline Hydrochloride.

Calculation is essential to determine part of Acidum hydrochloricum by molecular weight in order to

make a 100 mg/mL Amitriptyline solution.

Molecular weight of Amitriptyline: 277.4

Molecular weight of Acidum hydrochloricum: 36.5

Molecular weight of Amitriptyline Hydrochloride: 277.4 + 36.5 = 313.9

To compare the molecular weight of Amitriptyline Hydrochloride with Amitriptyline, the following

calculation is necessary.

313.9/277.4 = 1.132

The molecular weight of Amitriptyline Hydrochloride is 1.132 times of Amitriptyline.

So, if 25mg of Amitriptyline is used, it follows that the weight of Amitriptyline Hydrochloride should be:

25 mg × 1.132 = 28.3 mg.

Hence, 28.3 mg of Amitriptyline Hydrochloride is needed to make the correct standard solution.

Standard solution of Amitriptyline

Amitriptyline100 mg

1 mL

Amitriptyline Hydrochloride

AmitriptylineMolecular weight

277.4

Acidum hydrochloricumMolecular weight

36.5

No need for manual calculation

AP series can automatically calculate the sampling weight using the molecular amount of the standard sample, molecular

weight of unnecessary sample, and the target value in order to reach the correct concentration solution.

Just weigh the target weight value on display and the target weight of the standard sample can be obtained.

Target weighing value

Current sample value

Standard sample value

"OK" mark shown when target weight is reached.

Checking weighing conditions on the same display

Page 20: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

20

*1 AP-W Series only

USB Offers Greater Expandabi l i ty (USB host: AP-W Series only)

Equipped with an RS-232C connector, a USB device and a USB host as standard. You can now

simultaneously send output to both a computer and printer or connect a USB flash drive, a

barcode reader, or an external numeric keypad.

Transcription errors can be avoided and data can be recorded without a computer.USB and RS-232Care standard

USB host is availablefor AP-W Series

Display capture functionWeighing display can be recorded into USB memory in BMP format. User name,

date/time, and setting can be shown with display information.

The user name, time, measurement conditions, pass/fail judgments, and other

information displayed on screen can be saved as is, enabling the recording of

measurements, and checks after measurements.

Numeric keypadConnecting a common external numeric keypad makes it easier to enter numeric values. This is especially

useful for entering the mass value of weights, setting upper/lower limit values for the comparator function, or

entering the sample count during piece counting mode.

Barcode readerA barcode reader can be connected. Simply reading a barcode makes it possible to input user ID/Password. It is

possible to manage sample IDs using barcodes.

An example of login by barcode

User001User ID card

LOGIN 01LOGIN 001

USB Connect

Can log in as User001

User002User ID card

LOGIN 02

User003User ID card

LOGIN 03

An ID and password are needed to log in to the AP series if protected access is activated. With the barcode, an operator can log in by scanning

the barcode instead of inputting an ID and password.

* The latest information can be seen from the Shimadzu website (http://www.shimadzu.com/an/balance/)

USB flash driveConnecting a USB memory device allows you to record large amounts of weighing data in CSV format. Used in

combination with the interval output function, it also enables recording of long-term changes over time.

Example of a record:File nameDate and timeWeighing value

*The information saved will differ depending on the function used.

AP Series | 0.01 mg to 0.1 mg | Analytical BalancesAP Series 

| 

0.01 mg

to 0.1 m

g | 

An

alytical Balan

ces

Save Your Operation Equipped with USB as standard.*1

Includes many diverse functions to support users.

Page 21: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

1

An

alytical Balan

ces

21

Easy-to-Read Organic EL Display (All models)

Because the pixel elements in the organic electroluminescence display emit light, the screen can be seen clearly even in dark locations.

Multi-language display capability*2 provides a more intuitive operating interface. A wider viewing angle has also improved the visibility of

measurement values, which helps increase the efficiency of measuring operations.

*2 Japanese, English and Chinese

Clearly visible from the side

English example

Exceptional Visibility

The visibility remains the same even when viewed from different angles. The viewing angle is a wide expanse of ±85 degrees, both vertically and

horizontally. That means the display is clearly visible even when working beside the balance. A high-resolution dot-matrix display makes it easy to

read detailed text.

Per iodic Inspect ion Support Funct ion (AP-W/AP-X Series only)

AP series supports periodic inspections. The function allows inspection of repeatability, corner

load error, and linearity by simply following instructions displayed on the screen.

Example of printing

Select the inspection mode.

In this case, repeatability inspection is selected.

Place standard weights as instructed.

Results are displayed.

Printing sample

IL: Loaded weightI0: Zero value

Page 22: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

22

High-Secur i ty User Management (All models)

Operations can be kept secure with user ID and password protection. Access rights can be

specified separately for each user to prohibit unauthorized actions such as performing

calibration or changing the settings. User IDs can also be used for barcode management.

User Selection Screen

Pr int ing Data in Accordance with Var ious Regulat ions (All models)

Printing can be customized to indicate when the measurements were taken

and by whom. Users are free to set which items are to output, and in what

order. The date, time, calibration log, and other information can be printed

depending on the purpose of printing, which supports compliance with ISO,

GLP, and GMP.

<Printed content>

• Date

• Time

• User name

• Balance manufacturer name

• User ID

• Serial number

An example of printingTitle of result

Manufacturer name

Model name

Serial number

Date

Time

User name

Standard weight value

Weighing value before calibration

Weighing value after calibration

Signature

Minimum Measurement Value (Warning Funct ion) (All models)

Reproducibility can be confirmed by repeatedly measuring weights as instructed by AP

series. The minimum sample quantity is automatically determined from the standard

deviation and recorded in AP series.

If the minimum sample quantity requirement is not satisfied during measurement, an

indicator flashes to warn the user. Minimum sample quantity

Recipe Funct ion (AP-W Series only)

Sample recipes can be registered, allowing users to simply follow displayed instructions. This is convenient when compounding medicines.

• Balance ID

• Software version

• Minimum sample quantity

• Blank line

• Ruled line (--------)

(Achieve Your Preferred Compounding Process)

AP Series | 0.01 mg to 0.1 mg | Analytical BalancesAP Series 

| 

0.01 mg

to 0.1 m

g | 

An

alytical Balan

ces

For Regulation For the Pharmaceutical Industry

Page 23: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

1

An

alytical Balan

ces

23

Smart Sett ings (All models)

Response and stability settings can be changed during measurements with a single touch. Changing the settings for different applications can make

it even easier to use.

The indicator is operated using the left and right arrow keys. Moving the setting toward [R] prioritizes response, which

makes it easier to operate the balance. Conversely, moving it toward [S] makes it easier to stabilize weight values,

which can improve readability in environments with vibration.

User-friendly arrow keys Moving it left prioritizes response and moving it right prioritizes stability. Five setting levels are available.

Patented

Specific Gravity Measurement (All models)

In combination with an optional specific gravity measurement kit, the balance can be used to measure specific gravity. Operations are simplified

by a text-based navigation function. By using sinkers, the specific gravity of liquid can be measured as well. This allows measuring the specific

gravity of metals, rubbers, plastics, and other materials easily.

First measure the empty weight. Then place it in the container filled with water, as instructed on the screen.

The specific gravity value is displayed using simple steps.

PSC and Clock-CAL (AP-W/AP-X Series only)

A Perfect Self Calibration (PSC) function is included. The analytical balance automatically

detects any temperature changes that could affect sensitivity and automatically starts

calibration.

The Clock-CAL function enables automatic calibration at a pre-specified time (for example,

before starting work, during lunch, or after work hours).

Permissiblesensitivity error

Room temperature change

PSC (Perfect Self Calibration)

0

Roomtemp.

Sensitivityerror

8:00 a.m. 12:30 p.m. 5:00 p.m.

Automatically calibrate sensitivity at timesspecified by the Clock-CAL function.

Clock-CAL

And more... Wide Variety of Functions to Support Users

Page 24: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

24

X Series / Y Series Analytical Balances

Series X Series Y Series

Model AP124X AP224X AP324X AP124Y AP224Y AP324YCapacityMinimum DisplayCalibration WeightExternal Calibration Weight Range for Span CalibrationRepeatability (Standard deviation)Repeatability (for Low Loads)

Minimum Weight*1

LinearityResponse Time for race Measurements *2

Response Time*3

USB Host (Type A)USB Device (Type B)Recipe CompoundingHPLC Buffer Solution Preparationmol Conversion FunctionSample (Concentration) PreparationInspection Support FunctionClock-CALIonizerOperating Temperature/Humidity RangeSensitivity Stability Against Temperature RangePan SizeBody DimensionsWeightDisplayInput/Output Terminal

120 g 220 g 320 g 120 g 220 g 320 g0.1 mg

Built-in No45 to 120.009 g

(100 g)95 to 220.009 g

(200 g)95 to 320.009 g

(300 g)45 to 120.009 g

(100 g)95 to 220.009 g

(200 g)95 to 320.009 g

(300 g)0.1 mg 0.15 mg 0.1 mg 0.15 mg

0.1 mg(5 g low loads)

0.1 mg(10 g low loads)

0.1 mg(20 g low loads)

0.1 mg(5 g low loads)

0.1 mg(10 g low loads)

0.1 mg(20 g low loads)

200 mg±0.2 mg ±0.3 mg ±0.2 mg ±0.3 mg

2 sec.2 sec.

Not IncludedIncluded

Not IncludedNot Included

Not Included

Included

Included

Not Included

Not IncludedIncludedOptional

Not IncludedNot Included

5 to 40°C 20 to 85%*4

±2 ppm/°C (10 to 30°C)ø91 mm

Approx. 212(W)×367(D)×345(H)mmApprox. 7.0 kg Approx. 6.5 kg

OEL display (dot matrix)RS-232C (D-sub9P plug) USB device (Type B) Ionizer RS-232C (D-sub9P plug) USB device (Type B)

*1 According to USP Chapter 41. This is the tested value by the weight of the balance’s capacity of 5%.

*2 The response time for displaying 90% of added sample amount value in trace measurements (from 1mg)

*3 The response time value is typical.

*4 Non-condensing.

CapacityMinimum DisplayCalibration WeightExternal Calibration Weight Range for Span CalibrationRepeatability (Standard deviation)Repeatability (for Low Loads)

Minimum Weight*1

LinearityResponse Time for race Measurements *2

Response Time*3

USB Host (Type A)USB Device (Type B)Recipe CompoundingHPLC Buffer Solution Preparationmol Conversion FunctionSample (Concentration) PreparationInspection Support FunctionClock-CALIonizerOperating Temperature/Humidity RangeSensitivity Stability Against Temperature RangePan SizeBody Dimensions

WeightDisplayInput/Output Terminal

W Series Analytical Balances

Model

Series W Series

AP125WD AP225WDAP135W120 g / 52 g 220 g / 102 g

0.01mg 0.1 mg / 0.01 mgBuilt-in

IncludedIncludedIncludedIncludedIncludedIncludedIncludedIncludedOptional

45 to 135.0009 g 45 to 120.0090 g 95 to 220.0090 g(100 g) (100 g) (200 g)

30 mg

0.015 mg(5 g low loads)

0.1 mg / 0.02 mg 0.1 mg / 0.05 mg0.05mg 0.1 mg

±0.2 mg±0.1 mg  ±0.2 mg /±0.1 mg±0.2 mg /±0.05 mg

8 sec. 2 sec. / 8 sec.

5 to 40°C 20 to 85%*4

±2 ppm/°C (10 to 30°C)ø91 mm

Approx. 212(W)×411(D)×345(H)mm(power supply unit included)

Approx. 212(W)×367(D)×345(H)mm

Approx. 7.0 kgApprox. 7.9kgOEL display (dot matrix)

RS-232C (D-sub9P plug) USB host (Type A) USB device (Type B) Ionizer

AP324W320 g

AP224W220 g0.1 mg

AP124W120 g

95 to 320.009 g(300 g)

0.15 mg

0.1 mg(20 g low loads)

±0.3 mg

95 to 220.009 g(200 g)

0.1 mg(10 g low loads)

200 mg

2 sec.2 sec.

45 to 120.009 g(100 g)

0.1 mg(5 g low loads)

135 g

AP Series | 0.01 mg to 0.1 mg | Analytical BalancesAP Series 

| 

0.01 mg

to 0.1 m

g | 

An

alytical Balan

ces

AP Series Specifications

Page 25: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

1

An

alytical Balan

ces

25

AP135W (0.01 mg)AP125WD(0.01 mg / 0.1 mg)AP225WD(0.01 mg / 0.1 mg)

AP124WAP224WAP324W

0.01 mg / 0.1 mg model 0.1 mg model

AP124XAP224XAP324X

AP124YAP224YAP324Y

STABLO-AP Ionizer

*Power supply unit included.

Internal Windbreak PlateSMK-601

Specific Gravity Measurement Kit

EP-100 Electronic Printer EP-110 Electronic Printer(multifunction printer with liquid crystal display)

Options

Options

AP135W (0.01 mg)AP125WD(0.01 mg / 0.1 mg)AP225WD(0.01 mg / 0.1 mg)

0.01 mg / 0.1 mg model

*Power supply unit included.

Options

AP Series

Static Electricity Remover STABLO-AP Ionizer

Electronic Printer EP-100

Electronic Printer EP-110 (Multifunction Printer with Liquid Crystal Display)

Label Roll Paper for EP-100/110 (10 Rolls)

Specific Measurement Kit SMK-601

Display Protective Cover (Set of 5)

USB Cable

RS-232C Cable

AC Adapter (Standard Accessory)

Internal Windbreak Plate

RSIO Interface Cable

Page 26: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

26

What is “ion balance”?

AC method

Concept of static removal

: Effective area

DC method

AC method: AC voltage is applied on the discharge needle and a well-balanced mixture of positive/negative ions is emitted in rapid alternation from one electrode.DC method: DC voltage is applied to a couple of electrodes. One is positive and the other is negative. Each electrode emits ions of one polarity only. An effective static removal angle is limited if the two electrodes are distanced. As electrodes deteriorate, initial ion balance is lost.

With the high-frequency AC corona discharge method, Shimadzu’s STABLO-AP ionizer provides a stable ion balance and excellent static removal performance on samples and containers.Precision weighing work becomes remarkably efficient.Electrodes are safely housed inside the unit.

Not neutralized (negative charge remains)

Sample Sample

Inversely charged (results in positive charge)

Electrod

e

Example: negatively charged sample

1

Negative static charge is neutralized by positive ions.

5

Well-balanced mixture ofpositive/negative ions areemitted in rapid alternation.

2

AC coronadischarge

Ions are appliedto sample3

Only the opposite charge ions are attracted.

4

If ion balanceis poor……

Ion balance is the balance of positive and negative ions that are supplied by an ionizer.If ion balance is poor, static electricity is not removed or inverse charging may result.

AC Method Produces Excellent Ion Balance

Static Electricity Removal by Ion Irradiation

on bbaalannnceeoor……………

Electrod

es

F e a t u r e s o f

STABLO-AP provides reliable measurement by removing static electricity.

— an excellent solution against

static electricity.

AC corona discharge method enables excellent ion polarity balance Wide angle static removal High performance maintained over a long period of use No inverse charging Shimadzu's unique 3-Way Ionizer: hand-held / on stand

Shimadzu’s unique3-Way positioning

Hand-held/On stand

Compar i son of S ta t i c Remova l T ime (Typical Examples)

Static Removal Time (sec)

1000

900

800

700

600

500

400

300

200

100

0

STABLO-APPrevious model

0 2 4 6 8 10 12 14 16 18 20

Measurement Conditions · Time from ±1000 V to ±100 V · 150 × 150 mm CPM (20 pF) used · Distance between CPM and ionizer: 100 mm

Stat

ic C

har

ge

Vo

ltag

e (V

)

Quicker!

10 timesQuicker

Static Remover (Ionizer)Shimadzu's proprietary 3-Way ionizer foranalysts troubled by static charging of samplesor containersOne-touch attachment and removal adds evenmore convenience

Special 3-Way Ionizer for Electronic Balances

STABLO-APSTAB

LO-AP 

| Static Rem

over (Ionizer)

Page 27: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

1

27

Ion Generation Method

Ion Balance

Effective Static Removal Range

Static Elimination Time (approx.)

Ozone Concentration

Electrode Probes

Weight

Operating Temperature and Humidity

Rated Electric Power Supply

AC corona discharge method

±10V

Approx. 400 mm from the outlet

1 second (Typical value) (from ±1000 V to ±100 V)

0.06ppm

Tungsten (durability: 30,000 hours)

Approx. 710 g (Main unit: 395 g, Stand: 315 g)

0 ºC to + 40 ºC, 25 % RH to 85 % RH (non-condensing)

DC 24 V, 1.0 A

Model name STABLO-AP

When the powder in the Petri dish iselectrically charged, and the numericalvalue fluctuates

When the powdered medicine paper iselectrically charged, and the numericalvalue is unstable

When the measurement spoon iselectrically charged, and bringing it nearthe pan affects the numerical value

Static electricity keeps the sample out of the ampoule

Plastic wrap sticks to rubber gloves

Plastic wrap adheres to rubber gloves,making it difficult to work with.

Fasten STABLO-AP to the stand, andremove the static from the gloves.

The static is removed in about 10 seconds,and the plastic wrap no longer sticks.

The sample is hard to handle because itadheres to the ampoule inlet and sides.

STABLO-AP removes the charge from theampoule.

The static charge is gone in seconds.This improves productivity.

BAD! GOOD!

BAD! GOOD!

Mount the STABLO-AP in the balance and use it as a built-in model

Application

STABLO-AP is convenient when using an electronic balance

Static Rem

over (Io

nizer)

Specifications

l

Page 28: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

28

Analytical Balances

AUseries

Multi Functional Analytical Balance

AUW-D/AUX/AUY Series AUW Series

AU Series | 0.01 mg to 0.1 mg | Analytical BalancesAU

Series | 

0.01 mg

to 0.1 m

g | 

An

alytical Balan

ces

UniBloc Analytical BalancesAUW-D series dual-range semi-micro balancesAUW/AUX/AUY series analytical balances

Excellent Weighing PerformanceCompact UniBloc mechanism and digital processing technology produce fast response and

stability at the same time.•

Shimadzu’s unique Balance Keys

(http://www.shimadzu.com/an/balance/balance_keys/index.html)

a standard feature.

Measurement results can be transmitted to Excel or other Windows applications without

installing any additional software on your computer. All you have to add is one RS-232C

cable.

Piece counting, various mass units, below-weigh hook, specific gravity measurement

software are all standard features.

Excellent response, stability and zero return performance – in a semi-micro balance.

Choose one of the two models according to your field requirements.

Data can be automatically output at time intervals set in the range from 1 second to 99 minutes 59 seconds. This function can be also combined with WindowsDirect. (AUW-D/AUW/AUX models)

Interval Timer4

Calibration report can be automatically printed using an optional electronic printer. Date and time are also output to meet GLP/GMP/ISO requirements.

GLP/GMP/ISO calibration reportiOperator can choose from two fully-automatic span calibration methods. “PSC” is initiated based on temperature change detection, whereas “Clock-CAL” operates at user pre-set times (up to three times a day).

Restrainedsensitivity

error band

Ambient temperature change

Fully-automatic calibration

Sens

itivi

ty e

rror

0

Ambient temperature

Calibrations

SET

SET

SET8:00 12:30 17:30

All models a standard standard RS-232C interface for easy integration with other devices and computers.

RS-232C interface

SpecificGravity

Installing the optional SMK-401 specific gravity kit transforms the balance into a dedicated instrument for measuring specific gravity or density. Specific gravity measurement software is already installed in the Shimadzu balance.

Specific Gravity MeasurementChoice of fully-automatic calibrations: PSC and Clock-CAL

Automated calibration can be started by pressing keys. (AUW-D,AUW,AUX series)Also, your external calibration weights can be used for span calibration. (All models)

Touch-key calibration

In addition to piece counting, the balance can also perform measurements as percentages and in a variety of mass units, such as carat.

Piece Counting and Unit ConversionPCS

For Applications

Page 29: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

1

An

alytical Balan

ces

29

AUW-DSeries

AUWSeries

AUXSeries

AUYSeries

AUSeries

Capacity

Minimum display

Pan size (mm)

Body Dimensions

Weight

Model nameAUW-D Series AUW Series AUY SeriesAUX Series

AUW220D AUW120D AUW320 AUW220 AUW120 AUX320 AUX220 AUX120 AUY220 AUY120

Application Keyboard AKB-301

Specific Gravity Measurement Kit SMK-401

STABLO-AP

80mm dia approx.

Approx. W220 × D330 × H310 mm

7 kg approx.

220 g/82 g 120 g/42 g 320 g 220 g 120 g 320 g 220 g 120 g 220 g 120 g

0.1 mg/0.01 mg 0.1 mg 0.1 mg 0.1 mg 0.1 mg 0.1 mg 0.1 mg 0.1 mg 0.1 mg

Optional Accessories

Electronic Printer EP-100

Electronic Printer EP-110

Specific Gravity Measurement Kit SMK-401

In Use Protection Cover

RS-232C Cable

USB Conversion Cable

Application Keyboard AKB-301

Foot switch FSB-102PK

Foot switch FSB-102TK

Description

Countermeasures for Static ElectricitySpecial 3-Way Ionizer for Electronic Balances

STABLO-AP

Description

Electronic Printer EP-100

Electronic Print Electronic Printer EP-110

er lectronic Printer El

Page 30: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

30

Analytical Balances

ATseries

The balance has built-in motor-driven calibration weights.Sensitivity can be calibrated whenever needed by a single key press.

A built-in piece counting function enables balances to be used as parts counters (piece scales).

Internal Calibration (ATX only)

Piece Counting

Standard Models of Analytical Balances

b

This is convenient when formulating (preparing) multiple substances.

Formulation Mode6

Measures a percentage value with respect to a preset reference.

Percentage Measurement

AT Series | 0.1 mg | Analytical Balances

Economical Analytical BalanceEquipped with UniBloc

• Adopts UniBloc, which provides excellent impact resistance,

responsiveness, and stability

• Equipped with the Easy Setting function, so responsiveness and

stability can be adjusted during measurements

• Buy a separately available I/O-RS cable to import the results to a PC

(Equipped with the WindowsDirect function)

Indicator

Excellentresponsiveness

Excellentstability

• For super-fast measurements• For improved productivity• For measuring out and mixing fixed quantities of liquids and powders

• If the indicator is unstable i.e. When the work site is continuously subject to fairly strong vibrations• When continuous airflow often causes the indicator to fluctuate

AT Series 

| 

0.1 mg | 

An

alytical Balan

ces

Smoothly!

Precisely!

Easy Setting

This displays pass, high, or low judgments.

Checkweighingu

Page 31: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

1

31

ATXSeries

ATYSeries

I/O-RS conversion cable USB-serial adaptor

Optional Accessories

EP-100 Printer

EP-110 Printer

I/O-RS conversion cable

USB-serial adaptor

Protective cover (5 pcs)

AC adaptor (provided as standard with main unit)

Description

ATX/ATYSeries

Capacity

Minimum display

Pan size (mm)

Dimensions

Weight

Model

Approx. 91 dia.

0.1 mg

Approx. W213 × D356 × H338 mm

220 g

ATX224

120 g

Approx. 6.2 kg

ATX124

82 g

ATX84

220 g

ATY224

120 g

Approx. 6.0 kg

ATY124

62 g

ATY64

An

alytical Balan

ces

Countermeasures for Static ElectricitySpecial 3-Way Ionizer for Electronic Balances

STABLO-AP

Description

Electronic Printer EP-100

Electronic Prin Electronic Printer EP-110

I/O-RS nter ctronic PrinterElec

STABLO-AP

320 g

ATY324

320 g

ATX324

Page 32: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

1

32 33

An

alytical Balan

ce

Shimadzu

BalancesM

od

el Nam

e

F l a g s h i p M o d e l s

AUseries

Analytical Balances

S t a n d a r d M o d e l s

ATseries

General PurposeAnalytical Balances

Functions

Clock function

Specific gravity measurement

Weigh below hook for hanging measurement

Backlight

Analog bar graph display

Interval timer output

320 g capacity

Piece counting

Clock-CAL

Built-in weights for sensitivity calibration

Formulation

Percentage measurement

UniBloc

Measurements in semi micron range

Perfect self sensitivity calibration

Functions

AUW-

D

AUW

AUX

ATX

ATY

AUY

Piece counting

Formulation

Built-in weights for sensitivity calibration

Easy Setting

Percentage measurement

Weight check

320 g capacity

UniBloc

Case material Aluminum die cast Case materialABS plastic

Weight checkIt is possible to measure out target mass, and display pass/fail judgments based on reference mass.

Built-in perfect self calibration (PSC) function (AUW-D, AUW, and AUX only)

Detects ambient temperature changes with an impact on sensitivity, and automatically performs sensitivity calibration.Built-in Clock-CAL function (AUW-D and AUW only)

These balances perform sensitivity calibration automatically at preset times.

■ Perfect self calibration (PSC)/ Clock-CAL functions are included

■ These balances have a built-in clock function. (AUW-D, AUW, and AUX only) Data can be logged with the date and time.This is ideal for establishing the measurement management and traceability required by GLP, GMP, and ISO 9000.

The optional SMK-401 is required.

The Easy Setting function eliminates troublesome settings.They can be used anywhere, at any time.

Five types of sample weight units can be registered.

For measurements down to 0.01 mg

For measuring counts of various samples

For measurements with referenceweights configured

For measuring specific gravity

For measuring samples 220 g or heavier

For consistently good precision

For balances that make weighing powdersand liquids easyFor use in environments subject to windand vibrationsFor selectable stability and response

Recommended

for the Following

Easy SettingEasy Setting

Weight checkWeight check

Clock function

Specific gravity measurement

Weigh below hook for hanging measurement

Backlight

Analog bar graph display

Interval timer output

Clock-CAL

Measurements in semi micron range

Perfect self sensitivity calibration

Clock function

Specific gravity measurement

Weigh below hook for hanging measurement

Backlight

Analog bar graph display

Interval timer output

Clock-CAL

Measurements in semi micron range

Perfect self sensitivity calibration

Analytical

The ATX/ATY seriesare recommendedThe AUW/AUX/AUY series

are recommended

For outputting changes in samplequantity over time

When a chemical resistant metallicbody is needed

For management of calibration recordsand measurement data by date and time

Page 33: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

1

32 33

An

alytical Balan

ce

Shimadzu

Balances

Mo

del N

ame

F l a g s h i p M o d e l s

AUseries

Analytical Balances

S t a n d a r d M o d e l s

ATseries

General PurposeAnalytical Balances

Functions

Clock function

Specific gravity measurement

Weigh below hook for hanging measurement

Backlight

Analog bar graph display

Interval timer output

320 g capacity

Piece counting

Clock-CAL

Built-in weights for sensitivity calibration

Formulation

Percentage measurement

UniBloc

Measurements in semi micron range

Perfect self sensitivity calibration

Functions

AUW-

D

AUW

AUX

ATX

ATY

AUY

Piece counting

Formulation

Built-in weights for sensitivity calibration

Easy Setting

Percentage measurement

Weight check

320 g capacity

UniBloc

Case material Aluminum die cast Case materialABS plastic

Weight checkIt is possible to measure out target mass, and display pass/fail judgments based on reference mass.

Built-in perfect self calibration (PSC) function (AUW-D, AUW, and AUX only)

Detects ambient temperature changes with an impact on sensitivity, and automatically performs sensitivity calibration.Built-in Clock-CAL function (AUW-D and AUW only)

These balances perform sensitivity calibration automatically at preset times.

■ Perfect self calibration (PSC)/ Clock-CAL functions are included

■ These balances have a built-in clock function. (AUW-D, AUW, and AUX only) Data can be logged with the date and time.This is ideal for establishing the measurement management and traceability required by GLP, GMP, and ISO 9000.

The optional SMK-401 is required.

The Easy Setting function eliminates troublesome settings.They can be used anywhere, at any time.

Five types of sample weight units can be registered.

For measurements down to 0.01 mg

For measuring counts of various samples

For measurements with referenceweights configured

For measuring specific gravity

For measuring samples 220 g or heavier

For consistently good precision

For balances that make weighing powdersand liquids easyFor use in environments subject to windand vibrationsFor selectable stability and response

Recommended

for the Following

Easy SettingEasy Setting

Weight checkWeight check

Clock function

Specific gravity measurement

Weigh below hook for hanging measurement

Backlight

Analog bar graph display

Interval timer output

Clock-CAL

Measurements in semi micron range

Perfect self sensitivity calibration

Clock function

Specific gravity measurement

Weigh below hook for hanging measurement

Backlight

Analog bar graph display

Interval timer output

Clock-CAL

Measurements in semi micron range

Perfect self sensitivity calibration

Analytical

The ATX/ATY seriesare recommendedThe AUW/AUX/AUY series

are recommended

For outputting changes in samplequantity over time

When a chemical resistant metallicbody is needed

For management of calibration recordsand measurement data by date and time

Page 34: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

34

Electronic Balances

UW/UXseries

Multi Functional Top-loading Balance

*Windbreak can be removed.UW4200SUW8200SUW2200HUW4200HUW6200H

UX4200SUX8200SUX2200HUX4200HUX6200H

UW420SUW820S

UX420SUX820S

UW220HUW420HUW620HUW820HUW1020H

UX220HUX420HUX620HUX820HUX1020H

The line of Shimadzu top-loading balances is engineered with the UniBloc mechanism, resulting in unrivaled response, stability and durability. Powerful features support any imaginable weighing application. The UW Series includes internal calibration and fully-automatic calibration functions.

The backlight LCD display can be clearly read in thedarkest of environments.

Backlight LCD

Just connect the optional printer to automaticallyoutput calibration results. Date and time aresupplied by the balance's built-in clock.

GLP/GMP/ISO Calibration Recordi

Calibration carried out at user-preset times (up to three times a day).Operators can work without unexpected interruptions.

When upper and lower thresholds are set, thebalance indicates if the sample weight is within therange (GO), over (HI) or under (LO).

Checkweighing Function

Restrainedsensitivity

error band

Ambient temperature change

Fully-automatic calibration

Sens

itivi

ty e

rror

0

Ambient temperature

Calibrations

SET

SET

SET8:00 12:30 17:30

A piece counting function is standard in addition tovarious unit conversions.

Piece CountingPCS

SpecificGravity

The standard specific gravity measurementcalculation function uses the Archimedes principle.Attaching the optional specific gravity measurementkit allows the balance to be used as a density meteror a hydrometer.

Specific Gravity Function

Data transfer port of UW/UX Series

Calibration is carried out when a temperature change has been detected.

PSC, fully-automatic calibration (UW only)

Clock-CAL, fully-automatic calibration (UW only)

Press just two keys to calibrate the balancewhenever calibration is necessary.

Automatic Touch-keyCalibration (UW only)

supplied by the ond time areclock.

cAko

on results. Date anbalance's built-in

UW/UX Series | 0.001 g to 0.1 g | Electronic BalancesUW

/UX

Series | 

0.001 g to

0.1 g | 

Electron

ic Balan

ces

Page 35: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

35

UWSeries

UXSeries

UXSeries

220 g 420 g 620 g 820 g 1020 g 420 g

UX220H UX420H UX620H UX820H UX1020H UX420S820 g 2200 g 4200 g 6200 g 4200 g 8200 g

0.001 g 0.001 g 0.001 g 0.001 g 0.001 g 0.01 g 0.01 g 0.01 g 0.01 g 0.01 g 0.1 g 0.1 g

UX820S UX2200H UX4200H UX6200H UX4200S UX8200S

UWSeries

220 g

UW220H

0.001 g

420 g

UW420H

0.001 g

620 g

UW620H

0.001 g

820 g

UW820H

0.001 g

1020 g

UW1020H

0.001 g

420 g

UW420S

0.01 g

820 g

0.01 g

UW820S2200 g

0.01 g

UW2200H4200 g

0.01 g

UW4200H6200 g

0.01 g

UW6200H4200 g

0.1 g

UW4200S8200 g

0.1 g

UW8200S

2

Electron

ic Balan

ces

Capacity

Minimum display

Pan size (mm)

Model name

Capacity

Minimum display

Pan size (mm)

Model name

108 × 105 Approx. 170 × 180 Approx.

108 × 105 Approx. 170 × 180 Approx.

Optional AccessoriesElectronic Printer EP-100 / EP-110

RS-232C Interface IFB-102A (needed only for multiple connection)

Small Size Windbreak (for models with capacity of 300g to 620g only) (Std. Acc. for models with readability of 0.001g)

Glass Windbreak (for models with capacity of 220g to 820g only)

Large Size Windbreak (for all models)

Specific Gravity Measurement Kit SMK-101 (for Large size pan 170×180mm)

Specific Gravity Measurement Kit SMK-102 (for Small size pan 108×105mm)

Protective in-use cover for key panel and display (5 pcs)

Small Animal Bucket set (For large pan models only)

Angle Adjuster and Wall Hook for Remote Display

Stand for Remote Display (1m high)

Foot Switch FSB-102PK (For printing)

Foot Switch FSB-102PK (For taring)

RS-232C Cable, for IBM PC/AT Compatibles (25P-9P, Null modem, 1.5m)

RS-232C Cable, for multiple connections (25P-25P, Null modem, 1.5m)

Application Keyboard AKB-301

Remote Display Unit RDB-201 with operation keys

Remote Display Unit RDB-202

Large size windbreakWBC-502

Glass windbreakWBC-102

Application Keyboard AKB-301

Static Remover

STABLO-AP

Description

Page 36: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

36

Electronic Balances

TW/TX/TXBseries

TW/TX/TXB Series | 0.0002 g to 1 g | Electronic BalancesTW/TX

/TXB

Series | 

0.0002 g to

1 g | 

Electron

ic Balan

ces

The beginning of the new standard.Extremely capable, but easy to operate.

Quickly adjust the desired ratio of stability andresponse for every application, even duringmeasurement, with one-touch operation.

Easy SettingBest fit to weighing application

Menu navigation keys are separated from weighing operation keys and arranged in a familiar 5-way navigation circle. Up, Down, Right, Left and Enter are the simple operational steps.

Menu Operation KeyEasy-to-operate Key Layout

Unit weights of up to five different samples can be easily entered, stored and recalled for use.

Expanded Piece Counting FunctionPCS

In addition to grams (g), weigh in %, number of pieces, ct, kg, mg, lb, oz, TTI, etc. or a custom conversion unit, more than 20 units in all. Change quickly from display of % or counting to gram weight (g) display.

Change among many weighing units and functions with a single touch

Compare samples to target values or pass/fail criteria and clearly indicate the results.

Comparator Function

Power the TXB series balances with an AC adaptor or batteries.

Can be used anywhere with battery power

Press just two keys to calibrate the balance whenever calibration is necessary (TW only). Calibration is very fast, taking only 15 sec.

Touch-key Internal Calibration

Page 37: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

37

TWSeries

TXSeries

TXBSeries

TW223L TW323L TW423LTX223L TX323L TX423L

TWC323L TXC323LTWC623L TXC623L

TX2202L TX3202L TX4202L

TXB2201L TXB6201LTXB4201L TXB6200L

TXB222L TXB622LTXB422L TXB621L

TXBSeries

220 g 420 g

0.01 g 0.01 g

620 g 620 g 2200 g 4200 g 6200 g 6200 g

0.01 g 0.1 g

Approx. W199 × D260 × H77 mm

Approx 1.5 kg

0.1 g 0.1 g 0.1 g

ø110 ø110 ø160

1 g

TXB222L TXB422L TXB622L TXB621L TXB2201L TXB4201L TXB6201L TXB6200L

TWSeries

220 g 320 g

0.001 g 0.001 g

420 g 620 ct (124 g)320 ct (64 g)

0.001 g 0.001 ct (0.0002 g)

Approx. W206 × D291 × H241 mm

Approx ø110 Approx ø80

Approx 4.2 kg Approx 4.1 kg

TW223L TW323L TW423L TWC623LTWC323L

TXSeries

220 g 320 g

0.001 g 0.001 g

420 g 2200 g 3200 g 4200 g 320 ct (64 g) 620 ct (124 g)

0.001 g 0.01 g 0.01 g 0.01 g 0.001 ct (0.0002 g)

Approx. W167 × D181 Approx ø80Approx ø110

Approx 3.8 kg Approx 2.8 kg Approx 3.8 kg

Approx. W206 × D291 × H241 mm Approx. W206 × D291 × H241 mmApprox. W200 × D291 × H80 mm

TX223L TX323L TX423L TX2202L TX3202L TX4202L TXC623LTXC323L

2

Capacity

Minimum display

Pan size (mm)

Dimensions

Weight

Model name

Capacity

Minimum display

Pan size (mm)

Dimensions

Weight

Model name

Capacity

Minimum display

Pan size (mm)

Dimensions

Weight

Model name

Optional Accessories

EP-100 Printer

EP-110 Printer

RS-232C cable

In-use protective cover

In-use protective cover for display

USB conversion kit

Description

Electronic Printer EP-100

Electronic Print Electronic Printer EP-110

er lectronic Printer El

Electron

ic Balan

ces

Page 38: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

38 39

Mo

del N

ame

Functions Functions

TW

TX

UniBloc

Built-in weights for sensitivity calibration

Piece counting

Peak hold

Capacity of 600 g/6 kg or more

Glass windbreak (Small pan models only) Glass windbreak (Small pan models only)

Interval timer output

Animal measurement mode

Weigh below hook for hanging measurement

Specific gravity measurement

Analog bar graph display

Backlight

Clock function

UW

UX

Case material Aluminumdie cast

Optional

Menu operation key

Easy Setting

UniBloc

Built-in weights for sensitivity calibration

Piece counting

Backlight

ABS plastic Case material

Perfect self calibration (PSC)

Clock-CAL

Five types of sample weight units can be registered.

For easy operation

When a glass windbreak is required

For measuring specific gravity

For weighing animals

When large-range capacity is required

Menu operation key

Easy Setting

Menu operation key

Easy Setting

Clock-CAL

Peak hold

Capacity of 600 g/6 kg or more

Interval timer output

Animal measurement mode

Weigh below hook for hanging measurement

Specific gravity measurement

Analog bar graph display

Clock function

Clock-CAL

Perfect self calibration (PSC)Perfect self calibration (PSC)

Peak hold

Capacity of 600 g/6 kg or more

Interval timer output

Animal measurement mode

Weigh below hook for hanging measurement

Specific gravity measurement

Analog bar graph display

Clock function

Shimadzu

Balances

F l a g s h i p M o d e l s

UW/UXseries

Electronic Balances

S t a n d a r d M o d e l s

TW/TXseries

General PurposeElectronic Balances

For registering multiple reference valuesfor piece counting

Recommended

for the Following

Electronic

The TW/TX seriesare recommended

The UW/UX seriesare recommended

When a chemical resistant metallicbody is needed

2

Electron

ic Balan

ces

The Easy Setting function eliminates troublesome settings.They can be used anywhere, at any time.

For balances that make weighing powdersand liquids easyFor use in environments subject to windand vibrationsFor selectable stability and response

■ These balances have a built-in clock function.Data can be logged with the date and time.This is ideal for establishing the measurement management and traceability required by GLP, GMP, and ISO 9000.

Perfect self calibration (PSC) function is included (UW only).

Detects ambient temperature changes with an impact on sensitivity, and automatically performs sensitivity calibration.Built-in Clock-CAL function (UW only)

These balances perform sensitivity calibration automatically at preset times.

■ Perfect self calibration (PSC)/ Clock-CAL functions are included

When perfect self calibration (PSC) andClock-CAL are required

When date and time output by thebuilt-in clock is required

Page 39: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

38 39

Mo

del N

ame

Functions Functions

TW

TX

UniBloc

Built-in weights for sensitivity calibration

Piece counting

Peak hold

Capacity of 600 g/6 kg or more

Glass windbreak (Small pan models only) Glass windbreak (Small pan models only)

Interval timer output

Animal measurement mode

Weigh below hook for hanging measurement

Specific gravity measurement

Analog bar graph display

Backlight

Clock function

UW

UX

Case material Aluminumdie cast

Optional

Menu operation key

Easy Setting

UniBloc

Built-in weights for sensitivity calibration

Piece counting

Backlight

ABS plastic Case material

Perfect self calibration (PSC)

Clock-CAL

Five types of sample weight units can be registered.

For easy operation

When a glass windbreak is required

For measuring specific gravity

For weighing animals

When large-range capacity is required

Menu operation key

Easy Setting

Menu operation key

Easy Setting

Clock-CAL

Peak hold

Capacity of 600 g/6 kg or more

Interval timer output

Animal measurement mode

Weigh below hook for hanging measurement

Specific gravity measurement

Analog bar graph display

Clock function

Clock-CAL

Perfect self calibration (PSC)Perfect self calibration (PSC)

Peak hold

Capacity of 600 g/6 kg or more

Interval timer output

Animal measurement mode

Weigh below hook for hanging measurement

Specific gravity measurement

Analog bar graph display

Clock function

Shimadzu

Balances

F l a g s h i p M o d e l s

UW/UXseries

Electronic Balances

S t a n d a r d M o d e l s

TW/TXseries

General PurposeElectronic Balances

For registering multiple reference valuesfor piece counting

Recommended

for the Following

Electronic

The TW/TX seriesare recommended

The UW/UX seriesare recommended

When a chemical resistant metallicbody is needed

2

Electron

ic Balan

ces

The Easy Setting function eliminates troublesome settings.They can be used anywhere, at any time.

For balances that make weighing powdersand liquids easyFor use in environments subject to windand vibrationsFor selectable stability and response

■ These balances have a built-in clock function.Data can be logged with the date and time.This is ideal for establishing the measurement management and traceability required by GLP, GMP, and ISO 9000.

Perfect self calibration (PSC) function is included (UW only).

Detects ambient temperature changes with an impact on sensitivity, and automatically performs sensitivity calibration.Built-in Clock-CAL function (UW only)

These balances perform sensitivity calibration automatically at preset times.

■ Perfect self calibration (PSC)/ Clock-CAL functions are included

When perfect self calibration (PSC) andClock-CAL are required

When date and time output by thebuilt-in clock is required

Page 40: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

40

BL Series | 0.001 g to 0.1 g | Top-Loading BalancesBL Series 

| 

0.001 g to

0.1 g | 

Top

-Load

ing

Balan

cesELB

Series | 

0.01 g to

1 g | 

Portab

le Electron

ic Balan

ces

Top-Loading Balances

BLseries

Basic Top-Loading Balances

BLSeries

BL-320S BL-220HBL-320H

BL-620SBL-3200SBL-2200HBL-3200H

BLSeries

High-resolution balances made affordable

Piece counting function is standard.

Piece counting functionPCS

220 g 320 g 320 g 620 g 2200 g 3200 g 3200 g

0.01 g 0.01 g0.001 g0.001 g

W160 × D124W100 × D100

0.01 g 0.01 g 0.1 g

BL-220H BL-320H BL-320S BL-620S BL-2200H BL-3200H BL-3200SCapacity

Minimum display

Pan size (mm)

Model name

Data transfer port of BL Series

Optional Accessories

Electronic Printer EP-100

Electronic Printer EP-110

In Use Protection Cover

Description

Remaining weighing capacity can be seen at a glance.

Analog bar graph display

Page 41: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

3

41

Basic To

p-Lo

adin

g B

alances

Portable Electronic Balances

ELBseries

ELB Series | 0.01 g to 1 g | Portable Electronic Balances

ELB120ELB200ELB300

ELB600SELB6000SELB600ELB1200ELB2000ELB3000ELB12K

300 g120 g

0.01 g

ELB120200 g

0.01 g

ø110

ELB200

0.01 g

ELB300600 g

0.05 g

ELB600600 g

0.1 g

ELB600S1200 g

0.1 g

ELB12002000 g

W170 × D130

0.1 g

ELB20003000 g

0.1 g

ELB30006000 g

1 g

ELB6000S12 kg

1 g

ELB12K

ELBSeries

Portable Electronic Balance

Precision without compromise

Battery operation makes it portable.

Two-way power supply(AC or Battery operation)

SpecificGravity

Optional specific gravity kit is available for extra efficiency.

Standard specific gravity software

Piece counting, percent display, and specific gravity modes are easily accessible.

Various application modesPCS

Capacity

Minimum display

Pan size (mm)

Model name

Optional Accessories

Electronic Printer “EP-100” “EP-110” (impact-dot print)

RS-232C Interface “IFB-102A”

Specific Gravity Measurement Kit “SMK-201” (except for ELB120,200,300 for rectangular-pan models only)

Carrying case

In-use protective cover

Below-weigh hook (except for ELB12K)

Description

Data transfer port of ELB Series

Easy battery replacement

Electronic Printer EP-100

Electronic Print Electronic Printer EP-110

er lectronic PrinterEl

Page 42: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

42

Precision Platform Balances

BW-K/BX-Kseries

BW-K/BX-K Series | 0.1 g to 1 g | Precision Platform Balances

Electronic Printer EP-100

Electronic Print Electronic Printer EP-110

er lectronic Printer El

Precision Balance for Heavy Samples

BW-K

/BX-K

Series | 

0.1 g to 1 g | 

Precision Platform Balances

MO

C-120H

 | 

0.001 g / 0.01%

 | 

Mo

isture A

nalyzer

BW-KSeries

Hookassy for below weighing

BW12KH

BW-K/BX-KSeries

12 kg 22 kg 32 kg 32 kg 52 kg12 kg 22 kg 32 kg

0.1 g 1 g0.1 g0.1 g

W345 × D250

1 g0.1 g 0.1 g 0.1 g

BX12KH BX22KH BX32KH BX32KS BX52KSBW12KH BW22KH BW32KH32 kg 52 kg

1 g 1 g

BW32KS BW52KS

BX-KSeries

The Shimadzu Precision Platform balances have been engineered with the innovative UniBloc mechanism since 1989. Powerful features support any imaginable weighing application. The BW-K Series includes internal calibration weight.

Capacity

Minimum display

Pan size (mm)

Model name

*Below weighing is optional

Data transfer port of BW-K/BX-K Series

Optional Accessories

RS-232C interface IFB-102A (for multiple connections)

Electronic Printer EP-100/110

Foot Switch FSB-102PK (For printing)

Application Keyboard AKB-301

USB-SERIAL Conversion Kit

RS232C cable

Below-weigh hook

Description

Application KeyboardAKB-301

Page 43: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

43

4

Moisture Analyzer

MOC-120HMoisture Analyzer with a Wide Sample Pan

MOC-120H

MOC-120H | 0.001 g / 0.01 % | Moisture Analyzer

Printer

Company nameModelSerial no.Instrument IDSample codeMeasurement date/timeMeasurement conditions storage areaMeasurement referenceMeasurement modeDrying temperatureAutomatic ending conditionsPredictive convergence range

Un-dried mass:

: Shimadzu Corporation: MOC-120H: D207300000: ABCD-123: B-20: 15:07 Aug. 8, 2007: 0: Dry basis moisture ratio: Comparative measurement: 110 ℃: 0.05 %: 0.5

: 5.6892 g

Measurement timeDrying temperatureMeasurement value (%)

Predicted measurement value

Dried mass : 4.8637 g

[Graph Format (GRP)]

Sample Output from Optional Printer

*1 Temperature calibration using the optional Temperature Calibration Kit may be necessary depending on the

measurement sample and the measurement conditions. Temperature calibration makes it possible to control

the drying temperature of the measurement sample more accurately.

Warning●Use this balance to heat samples to evaporate moisture for measurement.●The built-in heater will be hotter than the set temperature.●Samples must not be measured if there is a risk of an explosion or fire, or a dangerous chemical reaction from heating.

MOC-120H

Measurement method

Pan size

Minimum weight displayed

Moisture ratio measurement range

Minimum moisture ratio displayed

Maximum sample quantity

Measurement modes

Drying heat source

Temperature settings range

Unit dimensions and weight

Operational temperature and humidity range

Required power supply

Accessories

Model

Infrared heating/dry mass measurement

130 mm dia

0.001 g

0.01 to 100.00 %

0.01 %

120 g

Automatic operation mode, Timered operation mode, High-speed drying mode, Low-speed drying mode

Medium wave infrared quartz heater

30 to 200 °C (1 °C steps)

W220 × D415 × H190 mm 4.5 kg

5 to 40 °C, relative humidity of 85 % max.

100 to 120/220 to 240 VAC, 640 W max.

Sample pan × 2, pan holder, windbreak, sample pan tongs, aluminum sheet × 20, spatula

MOC-120H

Optional Printer and AccessoriesDescription

Printer set includes a connection cord and 1 roll of printer paper (thermal paper)

Printer paper (10 rolls)

Optional Accessories A Wealth of Accessories to Enhance Your Possibilities

Description

RS-232C cable

Sample pan

Aluminum sheets (500 pcs)

Temperature Calibration Kit*1

Protective display cover (5 pcs)

Measure the Moisture Ratio of Even Large orLarge Amounts of Samples• The moisture ratio is found by heating the sample with the built-in infrared heater.

• The sample pan measures 130 mm in diameter, which is optimal for large and large

amounts of samples.

• Importing results to a PC is easy (equipped with the WindowsDirect function).

• Equipped with the UniBloc aluminum block mass sensor.

Mo

isture A

nalyzer

Drying conditions during

measurement and the final

measurement value can be

graphed and printed out.

Page 44: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

Moisture Analyzer

MOC63uEasy, Reliable Moisture Content Measurements

2

31

4

Generally, the wider, thinner, and more uniformly the sample is spread, the more precise the measurement. Uniform heating is provided by adopting a cleverly shaped reflector (patent pending).

This automatically ends measurement when the moisture change(% margin) over 30 seconds drops below a set value.

The sample is dried at the highest temperature for the initial drying stage, and when the moisture has been reduced, it returns to the set temperature, shortening the measurement time.

Rapid Drying Mode

This gently heats samples that might form a surface film or are prone to degrading at high temperatures.

Slow Drying Mode

Drying conditions are changed step by step for samples that contain a lot of moisture, such as surface water or crystallization water.

Step Drying Mode

Automatic Ending Mode

This automatically ends measurement after a preset amount of time (t1).

Timed Ending Mode

Ending Modes

Alternate Drying Modes

The sample pan size is a spacious 95 mm dia.

● A real-time indicator has been adopted, which blinks to show the measurement status.

● A cross-shaped key layout has been adopted for excellent operability.

● The results are shown as a percentage using an LCD, backlit to enhance visibility.

● Graphics are provided to let you confirm the pan status in real time.

1

2

3

4

This product is certified underShimadzu's Eco label system.Energy savings: 30 % reduction over previous Shimadzu models

A Total of Five Modes Makes This Balance Compatible with a Variety ofSample Measurements

The sample is easy to see!Wide observation window

Temp

erature

Temp

erature

Moisture vaporization

Moisture vaporization

Temp

erature

Moisture vaporization

Temp

erature

Moisture vaporization

Temp

erature

Moisture vaporization

Margin (%)

Automatic ending

Drying stops

5 min

Ending set time

t (time)

t (time)

t (time)

t (time)

t 1

T1

T2

T3

t 2 t 3

t1 (set time)

30sec

200℃

MOC63u | 0.001 g / 0.01 % | Moisture Analyzer

This Unit Makes Moisture ContentMeasurements Quick and Easy

• The moisture ratio is found by heating the sample with the built-in halogen

heater to drive out the moisture.

• The measurement procedure is simple. Just close the heater cover to start the

measurement (automatic starting mode).

• Measurements are faster than the loss on drying method using a dryer.

• A USB connector is standard, so connecting to a PC is easy (built-in

WindowsDirect function).

• Equipped with the UniBloc aluminum block mass sensor.

MO

C63u 

| 

0.001 g / 0.01 %

 | 

Mo

isture A

nalyzer

44

Page 45: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

4

45

A USB connector is built in as standard for connecting to a PC. It can be used in conjunction with the WindowsDirect function.For Windows Vista, Windows 7, Windows 8 and USB port connections, check the Shimadzu website, or contact your Shimadzu representative.

Select the automatic starting mode, place the sample, and close the heater cover to start the measurements. The preparation for measurement is so simple that you do not even have to press the start key.

A Wealth of PC Connection Functions

Simple Operation

Warning●Use this balance to heat samples to evaporate moisture for measurement.●The built-in heater will be hotter than the set temperature.●Samples must not be measured if there is a risk of an explosion or fire, or a

dangerous chemical reaction from heating.

Sample Printout

ModelSerial no.Instrument IDSample codeDateTimeProgram no.Measurement referenceMeasurement conditionsDrying temperatureEnding conditions

Mass before measurement

Progressive measurementsElapsed measurement time:

Mass after measurement

:MOC63u:D209400009: 0000: 0040:Dec. 17, 2018: 16:27: 0:Wet basis moisture ratio:Automatic ending mode: 160 ℃: 0.05 %

: 5.161 g

Measurement value corresponding to themeasurement reference

: 4.747 g

Using the EP-100/EP-110

Compatible with printers (EP-100/EP-110).Equipped with I/O port.

Built-in RS-232Cinterface is standard.

Equipped with USB interface.Importing data to a PC is easy.

MOC63u

     Mass

     Moisture ratio

Repeatability *1

     Method

     Power

Temperature settings

Display

Pan size

Dimensions (mm)

Weight

Rated power

Ambient temperature

Measurement modes

Time settings

External output

Storage of measurement conditions

Data memory

Standard accessories

Model

60 g

0.02 g

0.001 g

0.01 %

0.15 %(2 g) 0.05 %(5 g) 0.02 %(10 g)

Halogen (straight tube)

Rated at 400 W

50 to 200 °C (1 °C interval) (up to 1 hour for settings over 180 °C)

Backlit LCD

95 mm dia

Approx. W202 × D336 × H157

Approx. 4.2 kg

430 VA

5 to 40 °C, relative humidity of 85 % max.

Standard drying mode (Automatic ending/timed ending)

Rapid drying mode (Automatic ending/timed ending)

Slow drying mode (Automatic ending/timed ending)

Step (3-stage) drying mode (Automatic ending/timed ending)

1 to 240 min, or continuous (up to 12 hours)

USB

Data I/O printer (EP-100/EP-110) output

RS-232C(D-sub9P)10 sets

100 items

Sample pans (3 aluminum pans), pan holder, windbreak, board,

aluminum sheets (50), pan handler, power cable, spare fuses (2),

protective display cover, hexagonal wrench

MOC63u Options A Wealth of Accessories to Enhance Measurement Possibilities

EP-100 Printer

EP-110 Printer

Protective display cover (5 pcs)

Aluminum pans (disposable) (50 pcs)

Fiberglass sheets (for liquid sample measurements) (100 pcs)

Temperature Calibration Kit

Sample pan (stainless steel) (5 pcs)

Sample pan (aluminum) (5 pcs)

RS-232C cable

USB cable set

Sample pan handler (stainless steel)

Halogen heater (for replacement)*2

Power cable

*2 The halogen heater can be removed and replaced by the user.Note: For delivery related matters, contact your Shimadzu representative.

*1 The repeatability (standard deviation) value is from a standard measurement (sample: sodium tartrate dihydrate). This value is not guaranteed for all samples, environments, and measurement conditions.

Capacity

MOC63u

Mo

isture A

nalyzer

Sample Measurement Results Output

Max. sample quantity DescriptionMin. sample quantity

Minimumdisplay

Heatsource

Page 46: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

46

Moisture Analyzer

MOC63u Sample Applications

M e a s u r e m e n t o f M i l k

Measurement of Milk

Measurement conditions: 140 °C/TIME 10 minutes

 87.7087.6187.6887.660.047

0.05

MOC63uSample mass (g) Moisture ratio (%)

1st2nd3rdAverageStandard deviationCV(%)

1.0811.0251.031

• Fiberglass sheets for liquid measurement were used to promote liquid evaporation.

• Two measurement conditions were used, timed ending and automatic ending modes.

Essentially, the same average values were obtained. With samples featuring a principal

component that has a relatively high evaporation temperature and also contains

moisture, the same results will be obtained regardless of the mode used.

(Before measurement) 1 g of milk was drippedon to a fiberglass sheet for liquid measurements.

(After measurement) The moisture hasevaporated from the milk, and the remainingfats have yellowed slightly.

The drying curve for milk in timedending mode is shown below.

M e a s u r e m e n t o f I n s t a n t C o f f e e

7.337.507.457.43

0.0871.18

MOC63uSample mass (g) Moisture ratio (%)

1st2nd3rdAverageStandard deviationCV(%)

0.9941.0790.980

• Commercially available powdered instant coffee was measured.

A sample of approximately 1 g was placed in the pan, and the pan was shaken to spread

the sample over the entire pan.

• Essentially no difference in the moisture ratio was evident in timed ending mode or

automatic ending mode. When a high drying temperature is set to shorten the drying

time, the radiant heat from the halogen lamp becomes significant, and sample surfaces

are sometimes scorched. Accordingly, with colored samples and samples prone to

degradation, it is better to set as low a drying temperature as possible.

(Before measurement) The sample was spreadevenly over the pan.

(After measurement) There was basically nodiscoloration.

The drying curve for instant coffee intimed ending mode is shown below.

Measurement of Instant Coffee

Measurement conditions: 120 °C/TIME 10 minutes

MOC63u | 0.001 g / 0.01 % | Moisture AnalyzerMO

C63u 

| 

0.001 g / 0.01 %

 | 

Mo

isture A

nalyzer

Photos of the milk before and after drying are shown below.

Photos of the instant coffee before and after drying are shown below.

Instant Coffee

Milk

Food

Food

Page 47: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

4

47

Mo

isture A

nalyzer Sam

ple A

pp

lication

s

●Summary of Results Found for the Moisture Ratios of Baked Sweets Using Several Methods

Ground up baked sweets loaded in theMOC63u

Baked sweets removed from thethermostatic chamber

Fiberglass sheet coated withdengakumiso and loaded in the MOC63u

Dengakumiso removed from thethermostatic chamber

A summary of moisture ratios and measurement times in the official test method, timed ending mode, and rapid drying mode is shown below.

Moisture ratio

39.4 %37.2 %40.1 %

Measurement time

5 hours

1 hour

7 min 45 sec

Measurement method

Official test method

Timed ending mode

Rapid drying mode

Moisture ratio

7.6 %7.1 %7.8 %

Measurement time

5 hours

15 min

5 min 10 sec

Measurement method

Official test method

Timed ending mode

Rapid drying mode

Windows Direct

0.00

1.00

2.00

3.00

4.00

5.00

6.00

7.00

8.00

9.00

00.00.00 00.01.00 00.02.00 00.03.00 00.04.00 00.05.00Time(min)

Mo

istu

re C

on

ten

t(%

)

Windows Direct

0.00

5.00

10.00

15.00

20.00

25.00

30.00

35.00

40.00

45.00

00.00.00 00.02.00 00.04.00 00.06.00Time(min)

Mo

istu

re C

on

ten

t(%

)

M o i s t u r e C o n t e n t M e a s u r e m e n t o f B a k e d S w e e t s

• In the official test method, the drying period in a thermostatic chamber is five hours, so

more than five hours are required to obtain the moisture ratio results.

• When the sample was measured using a moisture analyzer (in timed ending mode) at

110 °C, 10 °C higher than the 100 °C drying temperature specified in the official method,

results similar to those from the official method were obtained with a drying time of 15

minutes.

• At 15 minutes in timed ending mode, the moisture ratio from the official test method is

not reached. However, a moisture ratio similar to that from the official test method can

be obtained if the drying time is set slightly longer.

M o i s t u r e C o n t e n t M e a s u r e m e n t o f D e n g a k u m i s o( f e r m e n t e d s o y b e a n p a s t e )

• In the official test method, the drying period in a thermostatic chamber is five hours, so

more than five hours are required to obtain the moisture ratio results.

• When the sample was measured using a moisture analyzer (timed ending mode) at 105

°C, the same temperature as specified in the official test method, results similar to those

from the official test method were obtained in about one hour.

• At one hour in timed ending mode, the moisture ratio from the official test method is

not reached. However, a moisture ratio similar to that from the official test method can

be obtained if the drying temperature is increased, or if the drying time is set slightly

longer.

●Summary of Results Found for the Moisture Ratios of Dengakumiso Using Several Methods

A summary of moisture ratios and measurement times in the official test method, timed ending mode, and rapid drying mode is shown below.

Drying curve for moisture ratio ofbaked sweets measured in rapiddrying mode (vertical axis: moistureratio; horizontal axis: time)

Drying curve for moisture ratio ofdengakumiso measured in rapiddrying mode (vertical axis: moistureratio; horizontal axis: time)

Food

Food

Page 48: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

48

Rice seasoning loaded in the MOC63uRice seasoning removed from thethermostatic chamber

Ground up boiled fish paste loaded inthe MOC63u

Boiled fish paste removed from thethermostatic chamber

Moisture ratio

3.1 %2.5 %3.0 %

Measurement time

4 hours

15 min

3 min 35 sec

Measurement method

Official test method

Timed ending mode

Rapid drying mode

Moisture ratio

73.8 %69.7 %72.9 %

Measurement time

5 hours

1 hour

21 min 30 sec

Measurement method

Official test method

Timed ending mode

Rapid drying mode

Windows Direct

0.00

0.50

1.00

1.50

2.00

2.50

3.00

3.50

00.00.00 00.01.00 00.02.00 00.03.00Time(min)

Mo

istu

re C

on

ten

t(%

)

Windows Direct

0.00

10.00

20.00

30.00

40.00

50.00

60.00

70.00

80.00

00.00.00 00.05.00 00.10.00 00.15.00 00.20.00Time(min)

Mo

istu

re C

on

ten

t(%

)Moisture Analyzer

MOC63u Sample Applications

M o i s t u r e C o n t e n t M e a s u r e m e n t o f R i c e S e a s o n i n g

M o i s t u r e C o n t e n t M e a s u r e m e n t o fB o i l e d F i s h P a s t e

• In the official test method, the drying period in a thermostatic chamber is four hours, so

more than four hours are required to obtain the moisture ratio results.

• The sample was measured using a moisture analyzer at 110 °C, 5 °C higher than

specified in the official test method (timed ending mode). Despite the increased drying

temperature, the moisture ratio from the official test method was not reached at 1/4

the time from that test method.

• When the sample was measured in rapid drying mode to shorten the time, a value

similar to that from the official test method was obtained in 3 minutes and 35 seconds.

This is because heating the sample at 200 °C in step 1 caused immediate evaporation,

thereby promoting evaporation efficiency.

• In the official test method, the drying period in a thermostatic chamber is five hours, so

more than five hours are required to obtain the moisture ratio results.

• When the sample was measured using a moisture analyzer at 105 °C, the same

temperature as specified in the official test method, the results after a drying time of

one hour were slightly less than those from the official test method.

• At one hour in timed ending mode, the moisture ratio from the official test method is

not reached. However, a moisture ratio similar to that from the official test method can

be obtained if the drying temperature is set higher, or if the drying time is set slightly

longer.

●Summary of Results Found for the Moisture Ratios of Rice Seasoning Using Several Methods

A summary of moisture ratios and measurement times in the official test method, timed ending mode, and rapid drying mode is shown below.

●Summary of Results Found for the Moisture Ratios of Boiled Fish Paste Using Several Methods

A summary of moisture ratios and measurement times in the official test method, timed ending mode, and rapid drying mode is shown below.

MOC63u | 0.001 g / 0.01 % | Moisture AnalyzerMO

C63u 

| 

0.001 g / 0.01 %

 | 

Mo

isture A

nalyzer

Drying curve for moisture ratio ofice seasoning measured in rapiddrying mode (vertical axis: moistureratio; horizontal axis: time)

Drying curve for moisture ratio ofboiled fish paste measured in rapiddrying mode (vertical axis: moistureratio; horizontal axis: time)

Food

Food

Page 49: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

4

49

The table below summarizes moisture rat io measurements for var ious samples using the moisture analyzer.

Dog food

Table salt

Instant coffee

Coffee beans (raw)

Coffee beans (roasted)

Green tea

Corn starch

Sugar (granulated sugar)

White rice

Mayonnaise

Orange juice

Milk

Chocolate

Rolled oats

Tomato ketchup

Frozen sweets

Dried mangoes

Palm oil

Hand soap

Lipstick

Plastic (PMMA pellet)

Photocopier paper

Sodium tartrate dihydrate

Detergent (powdered)

Solid soap

Water-based paint

Sludge cake

Potting soil

Sawdust

Baked sweets

Dengakumiso

Rice Seasoning

Boiled fish paste

Sake lees

Salted rice malt

Soy sauce

Miso

Sardine dumplings

Plastic (ABS pellet)

1 g

5 g

1 g

5 g

3 g

5 g

5 g

5 g

6 g

1 g

1 g

1 g

3 g

6 g

2.5 g

2.5 g

5 g

2.5 g

1 g

1 g

10 g

1 g

5 g

5 g

3 g

1 g

2 g

5 g

4 g

3 g

5 g

3 g

5 g

3 g

5 g

5 g

5 g

5 g

5 g

AUTO

TIME

TIME

AUTO

AUTO

AUTO

AUTO

AUTO

AUTO

TIME

AUTO

AUTO

AUTO

AUTO

AUTO

TIME

AUTO

TIME

AUTO

TIME

TIME

AUTO

TIME

AUTO

TIME

AUTO

AUTO

AUTO

AUTO

RAPID

RAPID

RAPID

RAPID

RAPID

RAPID

RAPID

RAPID

RAPID

TIME

0.05 %

10 min

10 min

0.05 %

0.05 %

0.05 %

0.02 %

0.05 %

0.05 %

10 min

0.05 %

0.05 %

0.01 %

0.05 %

0.1 %

12 min

0.05 %

5 min

0.05 %

3 min

25 min

0.05 %

15 min

0.05 %

16 min

0.05 %

0.05 %

0.05 %

0.05 %

3.0 % 0.1 %

2.0 % 0.1 %

2.0 % 0.01 %

1.0 % 0.01 %

1.5 % 0.01 %

2.0 % 0.05 %

1.0 % 0.01 %

2.0 % 0.05 %

0.5 % 0.02 %

12 min

160

200

120

140

140

120

180

160

200

160

140

140

140

200

140

140

120

120

200

100

100

200

160

160

200

200

200

120

160

Step 1 200Step 2 110

Step 1 200Step 2 110

Step 1 200Step 2 110

Step 1 200Step 2 105

Step 1 200Step 2 105

Step 1 200Step 2 115

Step 1 200Step 2 105

Step 1 200Step 2 115

Step 1 200Step 2 115

150

5:48

10:00

10:00

17:30

7:06

9:05

9:25

1:02

13:55

10:00

10:09

7:30

6:18

10:05

19:47

12:00

28:27

5:00

21:36

3:00

25:00

1:50

15:00

13:08

16:00

9:27

21:31

15:30

8:27

5:10

7:45

3:35

21:30

21:30

14:20

10:40

15:22

23:20

12:00

6.45

0.08

7.43

9.32

2.68

3.76

12.17

0.13

14.48

20.61

88.89

87.36

2.36

12.65

69.40

84.53

6.62

0.41

88.89

0.73

0.13

7.84

15.80

9.79

9.09

52.39

81.55

33.40

34.38

7.6

39.4

3.1

73.8

55.8

46.2

68.2

50.8

72.1

0.27

3.17

6.93

1.18

1.68

3.73

0.41

0.73

0.01

0.42

0.46

0.09

0.04

1.49

0.14

0.16

0.22

12.10

3.70

0.39

9.37

4.56

0.71

0.04

1.59

1.66

0.75

0.40

2.16

0.91

30.26

2.79

83.87

0.14

4.30

0.82

0.19

1.79

0.29

4.33

Note 1: Measurement times, moisture ratios, and CV (%) values are aggregated from three data cycles.Note 2: The CV (%) is the standard deviation divided by the average value, multiplied by 100 to represent it as a percent.

Measurement ModeSampleQuantity

Set Temperature(°C)

MeasurementTime (min)

MoistureRatio (%)

CV (%)Ending Conditions Finishing Conditions (% or min)

Moisture Analyzer

MOC63u Sample Applications

Step 1Step 2

Step 1Step 2

Step 1Step 2

Step 1Step 2

Step 1Step 2

Step 1Step 2

Step 1Step 2

Step 1Step 2

Step 1Step 2

Sample

Mo

isture A

nalyzer Sam

ple A

pp

lication

s

Page 50: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

Enhanced Support for

ISO/GLP/GMP

50

(Printout Samples)

EP-100/EP-110 | Electronic Printers

Electronic Printers

EP-100/EP-110

EP-100 / EP-110 | 

Electron

ic Printers

AP Series 

| 

0.01mg

~ 0.1m

g | 

Specific G

ravity An

alyzer

Normal Mode

Compatible Balance ModelsAP, AU, AT, U, TX, TXB, BX-K, BL, and ELB series,and MOC63u moisture analyzers.Note: The automatic setting function cannot be used with models that do not include the PRINT key,such as ELB series balances and MOC63u moisture analyzers.

Specifications

Statistical Calculation Mode

Manufacturer InformationDevice Name

Serial No.Sample Name (ID)

DateMeasurement Start Time

Lot No.

Measurement Values

Measurement End Time

Signature Field

Display

Protected date setting

Printing

Interface

Power supply

Battery

Installation environment

Model

Paper for printing: Regular paper (does not fade with age)

Method: 8-pin reciprocating impact dot matrix

Speed: Approx. 1.7 lines/sec. Printer head life: 1 million lines

Character size: Approx. W1.7 × H2.6 mm

USB B-Type female, RS232 (D-sub 9-pin male)

AC adapter: Input 100 to 240 V AC, 50/60 Hz; Output 12 V DC/1500 mA

Power consumption: 8 W (while printing) Standby power: 0.5 W (when not printing)

Temperature: 5 to 45 °C; Humidity: 10 to 80 % No condensation

EP-100OLED 128 × 64 Dot Matrix DisplayEasy-to-understand fluorescent dot matrix display

Password protectable (six-character)

EP-110

1500 to 2500 mAh capacity rechargeable nickel metal--

hydride (NiMH) batteries can be used (four AA cells).

Note: Dry cell batteries cannot be used.

Eliminating the need for an AC adapter connection, the printer can be used as a portable device. It also means the printer can be used in locations without a power supply outlet, such as within a fume hood. Note: Dry cell batteries cannot be used (compatible with nickel metal hydride batteries).

Powered by Rechargeable Batteries

Shared Functionality

EP-100 Function EP-110 Function

The OLED display makes it easier to determine the measurement mode-based status. The OLED display also ensures visibility even in dark locations.

Status Display with Enhanced Visibility for OLED Display

· Built-In Clock· Affordably Priced

· Enhanced Visibility for OLED Display· Includes Functionality for Preventing Date Alterations

Supports GLP/GMP Using Password Protection-Based Date/Time Alteration Prevention●Built-In Clock Date/time can be printed even for balances without a clock function.

●Customized Printing In addition to weight measurement values, print items can also

be added to the end.

●Easy Communication Settings Includes functionality (automatic setting function)

that automatically sets communication settings based on the given balance.

Note: This function is disabled for ELB series models and MOC63u moisture analyzers.

●Titles for measurement values can be freely customized for printing.

EP-110EP-100

Output Items

Title (Header)

Number of samples

Total value

Maximum value

Minimum value

Range

Mean value

Standard deviation

Coefficient of variation

Data suffix (footer)

N

T

MAX

MIN

RNG

MEAN

SD

CV

SymbolManufacturer information, device name, serial number

(S/N), date, measurement start time, and lot number

= MAX – MIN

= T / N

∑(Xi-MEAN)2/(N-1)(SD / MEAN x 100)%

Measurement end time and signature field

RemarksItem

Maintenance Parts

Recording Paper

Labeling Paper Rolls

Ink Ribbon

AC Adapter

Connection Cable

Description

Page 51: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

51

When combined with an optional specific gravity measurement kit, balances can be used to measure specific gravity.Operations are simplified by a text-based navigation function. By using sinkers, the specific gravity of liquid can be measured as well. This allows easily measuring of the specific gravity of metals, rubbers, plastics, and other materials.

Attach Special Optional Kit for Use as

Specific Gravity Analyzer

Specific Gravity AnalyzerSpecial Optional Kit for Use as

Gravity Analyzer

AP Series

Capacity

Minimum display

Pan size (mm)

Dimensions

Weight

Required power supply

Model

Approx. ø91Approx. W212 × D411 × H345 mm (including power supply unit) Approx. 212(W)×367(D)×345(H)mm

AC100V 270mA 50/60Hz

W Series X Series Y Series

135g

AP135W120g / 52g

AP125WD220g /102g

AP225WD120g

AP124W220g

0.1mg0.1mg / 0.01mg0.01mg

AP224W320g

AP324W120g

AP124X220g

AP224X320g

AP324X120g

AP124Y220g

AP224Y320g

AP324Y

Approx. 7.9kg Approx. 7.0kg Approx. 6.5kg

APseries

AP Series | 0.01mg ~ 0.1mg | Specific Gravity Analyzer

s, and other materials.

SMK-601 specific gravity measurement kit

First measure the in-air weight. Then place it in the container filledwith water, as instructed on the screen.

The specific gravity value is displayedusing simple steps.

Specific Gravity Measurement Kit

Note: The optional liquid density sinker is required for liquid density measurements.

Model SMK-601

Optional AccessoriesDescription

Liquid Density Sinker

Petri Dish, Square

5

6

Specific G

ravity An

alyzerPrin

ter

Simple!

Page 52: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

52

Specific Gravity Analyzer

AUseries

AU Series | 0.01 mg to 0.1 mg | Specific Gravity Analyzer

Measures a Variety of Gravity Values with the Immersion Method

Measures a Variety of Gravity Values

with the Immersion Method

AU

Series | 

0.01 mg

to 0.1 m

g | 

Specific G

ravity An

alyzerU

W/U

X Series 

| 

0.001 g to

0.1 g | 

Specific G

ravity An

alyzer

For standard sample

Two kinds of weighing pans as standard.

For floating sample

AUW Series + SMK-401

AUSeries

0.1 mg/0.01 mg

Approx ø80

Approx. W220 × D430 × H340 mm

Approx 7kg

AUW-D Series AUW Series

220 g/82 g

0.1 mg/0.05 mg

AUW220D120 g/42 g

0.1 mg/0.02 mg

AUW120D320 g

0.1 mg

AUW320

0.15 mg

220 g

0.1 mg

AUW220

0.1 mg

120 g

0.1 mg

AUW120

0.1 mg

320 g

0.1 mg

AUX320

0.15 mg

220 g

0.1 mg

AUX220

0.1 mg

120 g

0.1 mg

AUX120

0.1 mg

AUY Series

220 g

0.1 mg

0.1 mg

AUY220120 g

0.1 mg

0.1 mg

AUY120AUX Series

Attach the optional SMK401 Specific Gravity Measurement Kit to a balance in the AU series, and set the balance to specific gravity measurement mode. You can then use the balance as a specific gravity analyzer, capable of automatically calculating and displaying specific gravity values.Liquid density can also be measured by using an optional sinker.

Various models of balances are available, including a semi-micro (0.01mg) model. Choose the model best suited to the sample amount and required precision in your application.

Capacity

Minimum display

Repeatability

Pan size (mm)

Body Dimensions

Weight

Model name

Specific Gravity Measurement kit

SMK-401

Description

Optional Accessories

Liquid Density Sinker for SMK-401

Description

Page 53: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

6

53

Measures a Variety of Specific Gravity Valueswith the Immersion MethodAttach the optional SMK-101/102/201 Specific Gravity Measurement Kit to a balance in the UW/UX series, and set the balance to specific gravity measurement mode. You can then use the balance as a specific gravity analyzer, capable of automatically calculating and displaying specific gravity values.Liquid density can also be measured by using an optional sinker.

Measures a Variety of Specific Gravity Values

with the Immersion Method

Specific Gravity Analyzer

UW/UXseries

UW/UX Series | 0.001 g to 0.1 g | Specific Gravity Analyzer

In addition to the above-mentioned, balances with the mark are equipped with a specific gravity calculation function, so they can be used for specific gravity measurement.

UW/UX Series + SMK-101

Various models of balances are available. Choose the model best suited to the sample amount and required precision in your application.

The large submersible pan makes it easy to measure bulky samples.

SMK-101 for large pan*1*2

形 名P/N

420 g 620 g 820 g 1020 g820 g

Approx. 108×1055 Approx. 108×1055 Approx. 108×1055 Approx. 108×1055Approx. 108×1055

420 g 620 g 820 g 1020 g420 g 820 g

Approx. 108×1055 Approx. 108×1055 Approx. 108×1055 Approx. 108×1055Approx. 108×1055 Approx. 108×1055

Optional AccessoriesDescription

Liquid Density Sinker for SMK-101/102

Capacity

Minimum display

Pan size (mm)

Model

2200 g 4200 g 6200 g 4200 g 8200 g0.01 g 0.01 g 0.01 g 0.1 g 0.1 g

UW2200H UW4200H UW6200H UW4200S UW8200S

Approx. 170×180 Approx. 170×180 Approx. 170×180 Approx. 170×180 Approx. 170×180

2200 g 4200 g 6200 g 4200 g 8200 g0.01 g 0.01 g 0.01 g 0.1 g 0.1 g

UX2200H UX4200H UX6200H UX4200S UX8200S

Approx. 170×180 Approx. 170×180 Approx. 170×180 Approx. 170×180 Approx. 170×180

Model UX220H UX420H UX620H UX820H UX1020H

0.001 g 0.001 g 0.001 g 0.001 g0.01 g

UX820S UW220H UW420H UW620H UW820H UW1020HUW420S

0.001 g 0.001 g 0.001 g 0.001 g0.01 g 0.01 g

UW820S

Specific Gravity Measurement KitModel SMK-102 for small pan*1*3

*1 The optional liquid density sinker is required for liquid density measurements.*2 For UW/UX series large-pan (170 × 180 mm) types. The actual capacity is 100 g smaller than the capacity of the balance.*3 For UW/UX series small-pan (108 × 105 mm) types. The actual capacity is 290 g smaller than the capacity of the balance. Cannot be attached to the UW/UX 220H.

UW/UXSeries Balances (large pan type)

UW/UXSeries Balances (small pan type)

Models with built-in calibration weights

Models with built-in calibration weights

Capacity

Minimum display

Pan size (mm)

420 g

Approx. 108×1055

UX420S

0.01 g

Specific G

ravity An

alyzer

Page 54: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

54

Introduction to the Specific GravityMeasurement Procedures (AU Series)

Assemble the Specific Gravity Measurement Kit.1

Set the balance to specific gravitymeasurement mode. Then press the UNIT keyseveral times until the display unit changesto "▼d."

As shown in the photo at left,

"Air" will be displayed for a while,

and the in-air weight is then measured.

2

Press the O/T key to subtract the tare.3

Load the solid sample on thein-air pan.4

SoSimple!

Intro

du

ction

to th

e Specific G

ravity Measu

remen

t Proced

ures

Page 55: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

55

Load the solid sample on thesubmerged pan.6

When the stability mark is lit, press theCAL key.

Sample Data Example

Sample

Aluminum

Brass

Copper

Specific gravity

2.68±0.1

8.45±0.4

8.8 ±0.4

7

*Results will differ depending on the shape and surface status of the sample, and the measurement conditions. The values in the table are at best reference values, and their precision is not guaranteed.

8

A "*" will be displayed in the numerical display, and the specific gravity of the solid sample will be displayed.To return to in-air measurement, press the

CAL key to display "Air" for in-air weight

measurement.

5

When the stability mark is lit, press theCAL key.

As shown in the photo at left, "wAtEr" will be displayed for a while, and the submerged weight is then measured.

6

Intro

du

ction

to th

e Specific G

ravity Measu

remen

t Proced

ures

Page 56: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

56

Animal Balances

UW/UXseries

Attach an optional animal bucket to a UW/UX series balance, and set the unit to animal mode. The balance can now be used as a user-friendly animal balance.

Quick, Stable Measurements of Animal Weight

UWSeries

UXSeries

UW/UX Series | 0.01 g to 0.1 g | Animal Balances

The Clock-CAL function automatically performs sensitivity calibration at preset times, significantly reducing the labor for routine inspections. Naturally, one-touch sensitivity calibrations are also possible at any time.

UW series is equipped with built-in calibration weights

When the animal is unloaded, residual weight from excretions and other materials is automatically subtracted and the display is set to zero. The next animal can be loaded without pressing the TARE button, which increases efficiency.● Thanks to the specially developed animal measurement software, the weight of

moving animals is measured quickly and stably.

Animal Measurement Mode

Deep round bucket Rectangular bucketBucket for small animals

Three movement levels can be selected corresponding to the animal movement.Animals can be measured whether they are docile or extremely active.

When the animal is loaded and the stability mark is displayed, the weight is output automatically.Needless operation is eliminated to increase efficiency.

When the animal is unloaded, residual weight from excretions and other materials is automaticallysubtracted and the display is set to zero.

The next animal can be loaded without pressing the TARE button, which increases efficiency.

UW

/UX

Series | 

0.01 g to

0.1 g | 

An

imal B

alances

BW

-K/B

X-K

Series | 

0.1 g to

1 g | 

An

imal B

alances

UW/UXSeries (balance)

Capacity

Minimum display

Model

2200 g0.01 g

UW2200H4200 g0.01 g

UW4200H6200 g0.01 g

UW6200H4200 g0.1 g

UW4200S8200 g0.1 g

UW8200S2200 g0.01 g

UX2200H4200 g0.01 g

UX4200H6200 g0.01 g

UX6200H4200 g0.1 g

UX4200S8200 g0.1 g

UX8200SModels with built-in calibration weightsStandard models

Small Animal Bucket Shape: round / Size: bottom 110 dia. × top 200 dia. × height 130 (mm)

Deep Round Bucket Shape: round / Size: bottom 155 dia. × top 195 dia. × height 200 (mm)

Rectangular Bucket*1 Shape: rectangular / Size: bottom 250 × 210; top 290 × 250; height 150 (mm)

*1 The rectangular bucket can only be attached to the UX8200S and UW8200S.

Page 57: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

57

Attach an optional animal bucket to a BW-K/BX-K series balance, and set the unit to animal mode. The balance can now be used as a user-friendly animal balance.

BW-KSeries

BX-KSeries

Animal Balances

BW-K/BX-Kseries

Quick, Stable Measurements of Animal Weight

BW-K/BX-K Series | 0.1 g to 1 g | Animal Balances

● Models with a range of capacities are available. Ideal for medium weight measurements of rabbits and small dogs.

● Thanks to the specially developed animal measurement software, the weight of moving animals is measured quickly and stably.

● When the animal is unloaded, residual weight from excretions and other materials is automatically subtracted and the display is set to zero. The next animal can be loaded without pressing the TARE button, which increases efficiency.

Animal Measurement Mode

Small bucket setMedium bucket set

BW-K/BX-KSeries (balance)

Capacity*1 *2

Minimum display

ModelModels with built-in calibration weights Standard models

*1 When an animal bucket is attached, the capacity will be reduced about 2 kg from the value indicated.*2 When an animal bucket is attached, the capacity will be reduced about 6 kg from the value indicated. *3 The bucket cannot be attached to the BW12KH or BX12KH.

BX12KH BX22KH BX32KH BX32KS BX52KSBW12KH BW22KH BW32KH BW32KS BW52KS12 kg 22 kg 32 kg 32 kg 52 kg12 kg 22 kg 32 kg 32 kg 52 kg

0.1 g 1 g0.1 g0.1 g 1 g0.1 g 0.1 g 0.1 g 1 g 1 g

Medium Bucket (mainly suited to small dogs)*3

Bucket

Shared Options for the UW/UX & BW-K/BX-K

Description

EP-100 Printer

EP-110 Printer

RS-232C cable (1.5 m)

USB-serial conversion kit

Shape: rectangular / Size: bottom 305 × 215; top 335 × 245; height 215 (mm)Small Bucket (mainly suited to rabbits)

Shape: rectangular / Size: bottom 335 × 245; top 445 × 295; height 345 (mm)

7

An

imal B

alances

Page 58: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

58

• Eliminate manual entry and all the weighing data are saved automatically in a

safe database without transcription mistakes.

• Reports appropriate for weighing methods, such as the mass variation test,

drying weight loss test and particle size test, can be created automatically

after the measurement. In addition, customized reports featuring such

information as system conformance, content uniformity and elution tests

together with the analysis results obtained by HPLC, etc. can be created.

Improves Operational Efficiency and Data Reliability

Main Window of LabSolutions Balance

Integrated Management of Analytical Data on Network System Using LabSolutions

Integrate Analysis Data Acquired from Balances toAnalytical Network Data System Compliant with ER/ES Regulations

LabSolutions BalanceLabSo

lutio

ns B

alance

LabSolutions Balance

LabSolutions

Data search,analysis andapproval

Office

Other vendor’sinstrument

Thermal analyzer AA UV FTIR Balance

Server LC GC LCMS GCMS TOC

DB

To Establish an Internal AnalysisData Management System

Page 59: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

59

• Weighing results can be automatically saved in the database together with other information, including sample ID, operator

name, operation date and series number of instrument used. This enables quick data searching based on sample information.

• It allows setting up user authority to ensure only the authorized user can create a template for weighing.

• It prevents improper manipulation, unintended overwriting and deletion of data. In addition, measurement results, all the

operation histories and reasons will be saved in the database as log files.

Compliant with the Latest Data Integrity Guidance (U.S. FDA 21 CFR Part 11)

Integrated Report Creation Function Combines Analysis Results from HPLCand Weighing Results from Balance

LabSolutions Data Manager

SpecificationsWindows 7 Professional (32bit/64bit), Windows 10 Pro

Shimadzu AP, AU, AT and UW/UX series

Controls up to 2 balance units, generation of PDF files, interface supporting linkage to LIMS system (option)

OS

Compatible Instruments

Other Functions

Batch Analysis Window

Select Report Template

PDF

Automatically print reports and

create PDF files.

Report template formats

can be freely customized.

After Analysis

Note: Multi-data report creation (optional) is necessary to use this function.

Creation of Report TemplateIt enables creating the report by reading sample data and confirming the sample report at the same time.

8

LabSo

lutio

ns B

alance

Page 60: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

Accessories for Shimadzu Balances

Balances Optional accessories

Electronic Printer EP-100 / EP-110AUW-D/AUW / AUX /AUY Series

Foot Switch FSB-102TK (For taring)

Foot Switch FSB-102PK (For printing)

Specific Gravity Measurement Kit SMK-401

Application Keyboard AKB-301

RS-232C Cable, for IBM PC/AT Compatibles (25P-9P, Null modem, 1.5m)

In-use Protective Cover (5 pcs)

AP Series

Electronic Printer EP-100 / EP-110

IFB-102A-UNC

USB Conversion Kit

In-use Protective Cover (5 pcs)

I/O–RS Cable

ATX / ATYSeries

Optional accessories list

*1 USB serial adaptor and RS-232C cable for MOC are needed.

for UW/UX small-pan type

for UW/UX Series

Windbreak WBC-102

Large windbreak WBC-502

I/O–RS Cable

IFB-102A-UNC

Printer for MOC-120H

EP-110

EP-100

AUW-DAUWAUXAUY

TXB BL ELB BW-KBX-K MOC-120H

USB conversion kit with RS-232C cable

Foot switch

FSB-102TK

FSB-102PK

Specificgravitymeasurementkit

SMK-401

SMK-601

for TARE

for print

SMK-101, -102

✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓

[no need] [no need] [no need] [no need] ✓✓ ✓ [no need] [no need]

[no need] [no need] [no need] [no need] ✓✓ ✓ [no need] [no need] [no need]

MOC63u

✓ ✓ ✓

✓ ✓ ✓ ✓ ✓ ✓ ✓✓ *1

✓ ✓

UWUX

ATXATY

Application keyboardAKB-301

SMK-201for ELB large-panmodel

BL Series

ELB Series

Electronic Printer EP-100 / EP-110

In-use Protective Cover (5 pcs)

Simple Windbreak

Lid for Simple Windbreak

Electronic Printer EP-100 / EP-110

RS-232C Interface IFB-102A-UNC

In-use Protective Cover (5 pcs)

Specific Gravity Measurement Kit SMK-201 (Cannot be used with small-pan models)

IFB-102A-UNC

TX / TW / TXB / TXC / TWCSeries

Electronic Printer EP-100 / EP-110

In-use Protective Cover (5 pcs)

RS-232C Cable

BW-K / BX-KSeries

Electronic Printer EP-100 / EP-110

RS-232C Interface IFB-102A (for multiple connections)

Foot Switch FSB-102PK (For printing)

Application Keyboard AKB-301

MOC63u EP-100 Printer

EP-110 Printer

In-use Protection Cover for Display (5 pcs)

Aluminum Sheet

Fiberglass Sheet

Balances Optional accessories

EP-100 / EP-110 PrinterUW / UX Series

RS-232C Interface IFB-102A (for multiple connections)

Glass Windbreak (for models with capacity of 220 to 820 g only)

Large Size Windbreak (for all models)

Small Size Windbreak (for models with capacity of 300 to 620 g only) (Std Acc. for models with readability of 1 mg)

Specific Gravity Measurement Kit SMK-101(for models with capacity of 2200 g and up only)

Specific Gravity Measurement Kit SMK-102(for models with capacity of 420 to 820 g only)

Foot Switch FSB-102PK (For printing)

In-use Protective Cover (5 pcs)

Foot Switch FSB-102TK (For taring)

RS-232C Cable, for IBM PC/AT Compatibles (25P-9P, Null modem, 1.5 m)

RS-232C Cable, for multiple connections (25P-25P, Null modem, 1.5 m)

Application Keyboard AKB-301

Remote Display Unit RDB-201 with operation keys

Remote Display Unit RDB-202

Angle Adjuster and Wall Hook for Remote Display

Stand for Remote Display (1-m high)

Temperature Calibration Kit

Sample Pan (SUS)

RS-232C Cable

USB Connection Cable

Halogen Heater For Replacement

[no need]

[no need]

TXAP

Static Electricity Remover STABLO-AP Ionizer

Electronic Printer EP-100

Electronic Printer EP-110(Multifunction Printer with Liquid Crystal Display)

Label Roll Paper for EP-100/110 (10 Rolls)

Specific Measurement Kit SMK-601

Display Protective Cover (Set of 5)

USB Cable

RS-232 Cable

AC Adapter (Standard Accessory)

Internal Windbreak Plate

RSIO Interface Cable

6160

Optional AccessoriesOp

tion

al Accesso

ries

9

Op

tion

al Accesso

ries

Page 61: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

Balances Optional accessories

Electronic Printer EP-100 / EP-110AUW-D/AUW / AUX /AUY Series

Foot Switch FSB-102TK (For taring)

Foot Switch FSB-102PK (For printing)

Specific Gravity Measurement Kit SMK-401

Application Keyboard AKB-301

RS-232C Cable, for IBM PC/AT Compatibles (25P-9P, Null modem, 1.5m)

In-use Protective Cover (5 pcs)

AP Series

Electronic Printer EP-100 / EP-110

IFB-102A-UNC

USB Conversion Kit

In-use Protective Cover (5 pcs)

I/O–RS Cable

ATX / ATYSeries

Optional accessories list

BL Series

ELB Series

Electronic Printer EP-100 / EP-110

In-use Protective Cover (5 pcs)

Simple Windbreak

Lid for Simple Windbreak

Electronic Printer EP-100 / EP-110

RS-232C Interface IFB-102A-UNC

In-use Protective Cover (5 pcs)

Specific Gravity Measurement Kit SMK-201 (Cannot be used with small-pan models)

IFB-102A-UNC

TX / TW / TXB / TXC / TWCSeries

Electronic Printer EP-100 / EP-110

In-use Protective Cover (5 pcs)

RS-232C Cable

BW-K / BX-KSeries

Electronic Printer EP-100 / EP-110

RS-232C Interface IFB-102A (for multiple connections)

Foot Switch FSB-102PK (For printing)

Application Keyboard AKB-301

MOC63u EP-100 Printer

EP-110 Printer

In-use Protection Cover for Display (5 pcs)

Aluminum Sheet

Fiberglass Sheet

Balances Optional accessories

EP-100 / EP-110 PrinterUW / UX SeriesRS-232C Interface IFB-102A (for multiple connections)

Glass Windbreak (for models with capacity of 220 to 820 g only)

Large Size Windbreak (for all models)

Small Size Windbreak (for models with capacity of 300 to 620 g only) (Std Acc. for models with readability of 1 mg)

Specific Gravity Measurement Kit SMK-101(for models with capacity of 2200 g and up only)

Specific Gravity Measurement Kit SMK-102(for models with capacity of 420 to 820 g only)

Foot Switch FSB-102PK (For printing)

In-use Protective Cover (5 pcs)

Foot Switch FSB-102TK (For taring)

RS-232C Cable, for IBM PC/AT Compatibles (25P-9P, Null modem, 1.5 m)

RS-232C Cable, for multiple connections (25P-25P, Null modem, 1.5 m)

Application Keyboard AKB-301

Remote Display Unit RDB-201 with operation keys

Remote Display Unit RDB-202

Angle Adjuster and Wall Hook for Remote Display

Stand for Remote Display (1-m high)

Temperature Calibration Kit

Sample Pan (SUS)

RS-232C Cable

USB Connection Cable

Halogen Heater For Replacement

Static Electricity Remover STABLO-AP Ionizer

Electronic Printer EP-100

Electronic Printer EP-110(Multifunction Printer with Liquid Crystal Display)

Label Roll Paper for EP-100/110 (10 Rolls)

Specific Measurement Kit SMK-601

Display Protective Cover (Set of 5)

USB Cable

RS-232 Cable

AC Adapter (Standard Accessory)

Internal Windbreak Plate

RSIO Interface Cable

61

9

Op

tion

al Accesso

ries

Page 62: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

Physical Dimensions

AP124W, AP224W, AP324W, AP124X, AP224X, AP324X Weight: Approx. 7.0 kgAP124Y, AP224Y, AP324Y Weight: Approx. 6.5 kg

AP135W, AP125WD, AP225WD Weight: Approx. 7.9 kg

166213

344.

5

140.5(Aperture Dimension)

87.5259

ø91

9822

0.5(

Ap

ertu

re D

imen

sio

n)

135(

Ap

ertu

re D

imen

sio

n)

90.5

432.8367

243

421

170

180

6.5

156

HOOK FOR UNDER PAN

HOOK FOR UNDER PAN

166213

344.

5

136

73.5

(180)(407)

87.525990.5

44

170

ø91

135(

Ap

ertu

re D

imen

sio

n)

243

180

421

140.5(Aperture Dimension)

216.

5(A

per

ture

Dim

ensi

on

)

432.8367

98

156

6.5

62

Physical DimensionsPhysical D

imen

sion

s

AP Series

AUW-D/AUW/AUX/AUY Series ATX/ATY Series

6.5 24 309

163

99

126

423235

440

253

134

172

223

356

338

217

168

185

ø80

BELOW-WEIGH HOOK

1.5

1.5

ø20

5

2

3.6

2

16.5

3.5

SensorBELOW-WEIGH HOOK

Case bottom

185

163213

222

102

338

8

26 307

356

432

138

244

ø91

170

426

240

162

136

Page 63: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

63

Measurements in mm. 1 mm=.03937"

AW/AX/AY Series

BW-K Series BX-K Series

BL Series

Large-pan model Small-pan model

Figure shows combination with windbreak (standard only for BL220H and BL320H)

BW-K/BX-K Series

TW/TX/TXB/TWC/TXC Series

TX/TW series TXB series

212

260.3

198.

5

260.3

198.

5

77.1

77.1

160ø

110ø

21326.9

291

191.370.7

79.5

233.

2

181.8145

145

167.

8

200

147.

1

163

129.2

392.8

200

374.3192.370.7

291

161.5

127

10

Physical D

imen

sion

s

Page 64: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

64

Physical DimensionsPhysical D

imen

sion

s

Physical Dimensions

UW/UX large-pan model with large windbreak (optional accessory)

UW/UX small-pan model with glass windbreak (optional accessory)

UW/UX Series

BELOW-WEIGH HOOK

ø20

30.7

4.6

4

3

4.5 10

9

317

118

5758

191

78.8

5

180.

5

80

8417

119

202

166

379

(364)

85103

9

BELOW-WEIGH HOOKBELOW-WEIGH HOOK

317191

78.8

5

180

Small-pan model *1

Large-pan model

*1 Figure shows combination with simple windbreak (standard only for models with minimum display of 0.001 g).

The delivered windbreak may differ slightly in size and shape.

Page 65: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

65

Measurements in mm. 1 mm=.03937"

ELB Series

Large-pan model Small-pan model

220

415

190

400

MOC63u

336

174.4 161.6 3.7

84

144

144

129.864.5

24.6

(Th

e h

eig

ht

bet

wee

n p

an

a

nd

pro

tect

ion

gla

ss.)

157

201.6

160

202

25070.4

ø95

291.

4

13.6

MOC-120H

EP-100/EP-110

ø110

170

188 188

130

Front leg:144 / Rear leg: 158 Front leg:144 / Rear leg: 158

216216145145 56

58 58

56

188.

2

114.6 86.6

STABLO-AP

POWER RUN ALARM

POWER RUN ALARM

START/STOP

124

49

87

164

90147.7

147

1304

35

10±2 110±3

70±

3

10

Physical D

imen

sion

s

Page 66: C054-E032R Shimadzu Electronic Balances General … · Moisture Analyzer, world's first to ... Top-pan and torsion balance production started in 1918, ... Measurement Kit to use a

© Shimadzu Corporation, 2017

www.shimadzu.com/an/

For Research Use Only. Not for use in diagnostic procedures. This publication may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country.Company names, products/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation, its subsidiaries or its affiliates, whether or not they are used with trademark symbol “TM” or “®”.Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether or not they are used with trademark symbol “TM” or “®”.Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own.

The contents of this publication are provided to you “as is” without warranty of any kind, and are subject to change without notice. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication.

Printed in Japan 3655-10707-20ANS

Shimadzu Electronic Balances Demonstration Movies

https://www.youtube.com/playlist?list=PLCPY11zjvhZPmTi_xW1oGJeSuI-YR6qaV

ATX ATY Series

UniBloc

TX TXB TXC Series Top-loading Balances

Analytical Balance AP Series

Analytical Balance AP Series

Effects Of Static Electricity

Effects of static electricity

Improved Response Time of AP series

Sample Preparation by Analytical Balance, AP Series

Effects of Static Electricity

Recipe Preparation by Analytical Balance, AP Series SETUP

Recipe Preparation by Analytical Balance, AP Series OPERATION