Upload
nguyenkien
View
218
Download
3
Embed Size (px)
Citation preview
2018Shimadzu Electronic BalancesGeneral Catalog
C054-E032R
1918
1960
1970
1930
1995
2004
2003
2010
2011
1980
2000
2002
2007
1918
1960
1970
1918 Top-Pan Torsion Balance
1875 Establishment of SHIMADZU CORPORATION
1930 Chemical Balance1930
1958 Type L Direct-Reading Balance
1995 1995 EL Series Load Cells
2004 MOC-120HMoisture Analyzer,world's first to include aUniBloc sensor
2003 AU Series Analytical Balances,world's first to include a UniBloc sensor
2010
2011
AT SeriesAnalytical Balancedesigned foreasy operability
2007 TX/TXB Series General-Purpose Balancesdesigned for easy operability
MOC63u Low-Cost Moisture Analyzer with UniBloc sensor
BL SeriesSimple Balances
BW/BX SeriesGeneral-Purpose Balances
1970
D-1003Digital Balance
1981
AEL-160AnalyticalBalance
1985
AEL-200Analytical Balance
1978
ED Series
19801987
UniBloc integratedmass sensordeveloped
2000
BW/BX-K Series Medium-SizePrecision Platform Balances,the first to include a UniBloc sensor
UW/UX SeriesGeneral-PurposeBalance with UniBloc
2002
AW/AX/AY SeriesAnalytical Balances
LDS SeriesPlatform Balances
Introduction of UniBloc
2007 UniBloc maturation period
20162016 AP Series Analytical Balances
20182018 100th year of making balances!! Please continue choosing Shimadzu balances.
1875
Providing Balances and Scales for 100 YearsSupporting manufacturing in the future, utilizing 100 years of experience and knowledgeShimadzu began manufacturing balances in 1918. Throughout this 100-year history, we have been at the forefront of providing precision,
quality solutions for the most challenging R&D and QA/QC requirements. Our steadfast customer-focused commitment and unwavering dedication
to technical excellence are both hallmarks of our history and the principles that guide us into the future.
P 50 - Printer
P 51 - Specific Gravity Analyzer
P 56 - Animal Balances
P 58 - LabSolutions Balance
P 60 - Optional Accessories
P 62 - Physical Dimensions
SHIMADZUELECTRONIC BALANCES
A Tradition of Weighing Expertise
P 08 -
P 10 - Product Lineup
P 14 - AP Series
P 26 - Static Remover (Ionizer)
P 28 - Analytical Balances
P 36 - Electronic Balances
P 40 - Top-Loading Balances
P 41 - Portable Electronic Balances
P 42 - Precision Platform Balances
P 43 - Moisture Analyzer
Contents
P 06 - Diverse Range of Functions
P 04 - UniBloc
Excellent Performance forMultiple Industries
Established in 1875 in Kyoto, Japan, Shimadzu Corporation is one of the pioneers of scientific precision instruments.
Top-pan and torsion balance production started in 1918,and equal-beam analytical balances were introduced in 1925. Since their release, the continuous improvement of Shimadzu balances has contributed to research and development across all industries.
Around the turn of the 20th century, precision weighing was a time-consuming practice performed only by experienced operators. Placing the sample and small masses on pans hung from a beam scale with a moving indicator was a tedious process. Shimadzu strove continuously to streamline weighing procedures. The introduction of the direct reading analytical balance (patented in Japan in 1948) signified a new era in weighing technology. In the Type L balance, the sensitive mass-loading work was replaced by convenient dial operations. This reduced weighing time by 66% and, subsequently, reduced demand for conventional balances.
Shimadzu then added the top-loading direct reading balance with Roberval’s mechanism in 1959. Until recently many of these instruments were still utilized in modern laboratories.Shimadzu continued to pioneer new technologies, releasing its first electronic balance in 1971—the Digibalance. This release marked a
milestone in precision weighing, introducing simplicity and ease of use to analytical weighing.
Six years later (1977), the application of microprocessors in electronic balances further enhanced weighing performance. The compact ED Series provided substantial improvements in sensitivity, resolution, and stability.
More recently, Shimadzu has introduced user-friendly instruments and features to the market, such as :temperature-based fully-automatic calibration in 1985,the first one-piece force cell (OPF, later renamed UniBloc) in 1989, the high-sensitivity AEM-5200 Micro Balance in 1993,and the unique WindowsDirect feature perfectly suited for the computerized laboratory of the 21st Century.
Its most recent achievement is the AP Series, advanced performance balances featuring UniBloc and a high response speed, and which are applicable for a wide range of applications.
Moving forward, Shimadzu is committed to providing innovative products for the analytical marketplace.
Test results of impact resistance test withtop-loading balances (Minimum display: 10 mg)
Shimadzu balances advance to the UniBloc generation
The results of this impact resistance test prove Shimadzu UW/UX series balances with UniBloc technologyare the toughest. Put Shimadzu balances in your lab and experience UniBloc power.
Free-falling the weight (3 kg) at 4 sec intervals.(Weight was dropped from a height of 5mm for the first 100,000 impacts.After the first 100,000 tests, it was dropped from a height of 10 mm.)
No.1
START Loading:100,000 times
Force springbroke after22000 impacts
Balance wasnot functionalafter 10000 impacts
Additional Loading:10,000 times
2nd fulcrum springbroke after1400 impacts
Clear
Clear
Height: 5 mm Heiight: 10 mmmShimadzu UW6200H
A Top-loading balance
ElectromagneticsystemOne aluminumtype structureWirecut
Electromagnetic systemOne aluminumtype structureWirecut
B Top-loading balanceElectromagnetic systemAssembly typePress
C Top-loading balanceOthersOne aluminumtype structureWirecut
Test conditions
Impact resistance test for four balances
made by typical manufacturers.
(Shimadzu internal test)
Free-fall
OUT/IN
IN/OUT
ON/OFF
Top-loading balance
weight(app 3kg)
Electromagneticvalve
PLCcontrol
Airresource
Air cy
lind
er
Air cy
lind
er
4
U n i B l o c P o w e r !
5
UniBloc technology leads toa new world of measurement
pan
1st lever
1st force spring
1st fulcrum spring2nd force spring
2nd fulcrum spring
parallel
set
on
th
e b
ase
2ndlever
to coil
Number of parts: 1 pcVolume : app. 1/10 of conventional one
Conventionalmeasurement unitIt consists of app.70pcs with variousmaterials
Reliability
Stability Response
Keywords ofUniBloc features
5
pan
1st lever
1st force spring
1st fulcrum spring2nd force spring
2nd fulcrum springp
parallel
set
on
th
e b
ase
2ndlever
to coil
Number of parts: 1 pcVolume : app. 1/10 of
conventional one
Conventionalmeasurement unitIt consists of app.70pcs with variousmaterials
R llRelRelRelRelRelRelRelRelRelReRRelRelReliabiabiabiabiabiabiabiabiabiabiabiabiabbiabia iliiliiliiliiliiliiliiililiililitytytytytytytytytyyyyy
aaaaaabbbibilbilbilbilbilliititityitytyityityityityityyityty ReResRResResponponponponsse
Keywords ofK d fniBloc features
U n i B l o c f a m i l y o f b a l a n c e s
MOC63u UW/UX seriesBX-K/BW-K series ATX/ATY seriesTW/TX series AU series
Amount
1/70Volume
1/10
AP series
Shimadzu introduced one-piece force cell technology for precision balances in 1989. Today’s UniBloc is
created by high-precision electric discharge wire processing applied to a block of aluminum alloy, and
replaces the conventional electro-magnetic balance sensor assembly. UniBloc’s compact, uniform structure
ensures stable temperature characteristics, excellent response time and stable corner-load performance.
In addition, the UniBloc design permits a consistency of production that assures reliability and a long
operational life.
The updated UniBloc technology expands the UniBloc balance lineup, which now ranges from semi-micro
with a minimum display of 0.01 mg to precision platform balances up to 52 kg in capacity.
One-piece force cell patented in USA in 1989, No. 4799561, in China in 1991, No. 12729, in Japan in 1995, No. 1905686
UniBloc is a completely new mass sensor, developed by Shimadzu through further modification of its OPF
aluminum block mass sensor, a world's first in development. UniBloc is created by high-precision electric
discharge wire processing applied to a block of aluminum alloy in order to replace the conventional sensor
block assembly. As such, it uses no springs or screws. This uniform structure dramatically improves response and
temperature characteristics, and the simple yet compact design enhances impact resistance. Balances equipped
with UniBloc provide highly reliable mass measurement even with prolonged use.
Next-Generation Mass Sensor: UniBloc
The balance has built-in motor-driven calibration weights.
Sensitivity can be calibrated whenever needed with a single
key press.
b Internal Calibration
The balance has built-in calibration weights. Sensitivity is
calibrated with a simple lever operation. Sensitivity can be
calibrated easily, whenever needed.
c Single-Lever CAL
The balance can also run on dry cell
batteries, enabling use outdoors where no
power is available.
. Dry Battery Operation
Preset the upper and lower limit values to display pass, high
or low, depending on the sample weight.
u Checkweighing
Proper weight, high, low and other pass/fail judgments
can be indicated by a buzzer, or output externally as a
contact signal. (Optional comparator buzzer or relay
output interface required.)
1 Comparator Output
Naturally, weight measurements can be
taken even if the work site is dark, and
prolonged use at normal work sites will not
tire your eyes.
/ Backlight
Keys exclusively for menu
operations are arranged
separately from the
measurement keys. Menus can
be operated intuitively using
the cross-shaped key layout.
Easy-to-Operate Key Layout
Constantsensitivity
error
The perfect self calibration (PSC) function keeps thesensitivity error within a constant range at all times.
Room temperature changes
Electronic balances are precision instruments very susceptible to changes in
room temperature. Sensitivity must be calibrated every time the balance is used
since changes in room temperature influence mass measurement values, which
are not supposed to change. The balance detects changes in room temperature
that affect sensitivity, and automatically starts calibration using built-in
weights. As a result, sensitivity errors are always kept within a constant range.
This allows the operator
to concentrate on
measurement tasks
without having to worry
about sensitivity
calibration.
f Perfect Self CalibrationEasy Setting
Menu Operation Key The balance starts calibration using built-in weights at preset times. If you set
calibration times before important measurements (e.g. before starting work in
the morning, or during the lunch or evening break), the balance will
automatically start calibration when the preset time is reached. This lets you
take stable, reliable
measurements without
worrying about
sensitivity calibration.
a Clock-CAL
HighLevel
Functionality
01
Durability
02
ConvenientFunctions
03
Shimadzu Balances Offer a Diverse Range of Functions
6
+
0
−
Ro
om
tem
per
atu
reSe
nsi
tivi
tyer
ror
AM8:00 PM0:30 PM5:00
Sensitivity calibrated automatically at thetimes determined by Clock-CAL
During operation, if you want to make the display
slightly more stable, or alternatively, want to improve
the response speed, you can make one-touch
adjustments without interrupting measurement. A
special indicator is provided that instantly shows the
adjustment status.
With the optional printer connected, data
can be recorded with date and time
stamps. Calibration reports can also be
date- and time-stamped, which is ideal for
establishing the measurement
management and traceability required by
GLP, GMP and ISO 9001.
d Built-in ClockSimply connect an optional printer to automatically
print out which balance was calibrated when, and
the calibration results. Absolutely no troublesome
settings are required. Furthermore, the current date
and time can be printed anytime during
measurement.
i ISO Calibration Report
Connecting with LabSolutions lets you save data from
balances, HPLC and other analysis instruments to a
database, and create reports automatically. Uniform
data management means no transcription errors, and is
perfect for security.
LabSolutions Balance
A built-in piece counting function enables balances to be used as
parts counters (piece scales).
OPiece Counting
A specific gravity calculation function based on
the immersion method is built in.
Just attach the optional Specific Gravity
Measurement Kit to use a balance as a specific
gravity meter.
PSpecific Gravity Measurement
The weight of mice, rats, rabbits, and
other small animals can be measured.
Stable measurements are obtained even if
the animal moves.
5 Built-in Animal Measurement Mode
Results can be displayed in carats when
measuring precious stones.
Carat Measurement
ISOGLPGMP
04
Network
05
Applications
06
7
(AUW Series Printout Sample)
Date and time areautomatically printed
Balance modelBalance serial numberUser ID number
Value of the weight used
Balance measurementbefore calibration(adjustment)
Balance measurementafter calibration(adjustment)
The calibratorsigns here.
(AUW Series Printout Sampl(AUW SS i P i t t S l
om
m
n
m
d is
To Establish an Internal AnalysisData Management System
Excellent Performance for Multiple Industries
8
Chemical
Medical Products
Food
Cosmetics
• Weigh liquids and powders in development departments
• Measure specific gravity and moisture ratio of resin pellets, rubber, etc.
• Input mass values via connection to a titration system for quality management
• Measure mass and moisture ratio of dyes, pigments, and inks
• Measure and control materials accumulated on filters
• Control moisture ratio levels during catalyst production
• Check weights when receiving raw materials
• Confirm the net weight of final products
• Measure the moisture ratio and control the quality of raw materials and products
• Weigh trace quantities of additives
• Weigh raw materials during formulation
• Measure weight changes in creams and compresses at specified intervals
• Control the quality of product containers and cases
• Measure the moisture ratio of hair, etc.
• Control pharmaceutical usage quantities by measuring weight before and after use
• Weigh raw materials
• Confirm the weight of stents and other miniature medical devices
• Measure the moisture ratio and control the quality of raw materials and products
• Measure weight changes during animal experiments
• Measure drugs during drug manufacturing processes
9
Metals/Precious Metals
Automotive
Electronics
Academia
• Count the number of very small products
• Check the weight of coated steel sheets/plates after polishing
• Control the moisture ratio and specific gravity of iron and steel raw materials
• Measure trace quantities machined from metals, etc.
• Measure the specific gravity of rare metals and compare it to theoretical values
• Control the amount of wear on metal materials
• Weigh items when purchasing precious metals or bullion
• Check weights when manufacturing electronic circuit boards
• Measure tiny semiconductor parts
• Check for missing items in product packages based on weight
• Control the quantity of plastics used in LED lenses
• Measure exhaust gas accumulation on ceramic parts and filters
• Measure electrolyte injection quantities on lithium-ion battery production lines
• Measure moisture ratio in sheet materials
• Control contamination remaining on machinery parts
• Use for training students
• Manage reagent use by weight, in combination with a chemical substances management system
• Use in lectures to explain basic principles and theory
10
Product LineupProd
uct Lin
eup
0.01mg
0.1mg
0.001g(1mg)
0.01g~(10mg)
UW820H UX820H (820g/0.001g)
UW620H UX620H (620g/0.001g)
UW1020HUX1020H(1020g/0.001g)
UW420H UX420H (420g/0.001g)
TW423L TX423L(420g/0.001g)
TW323L TX323L (320g/0.001g)
BL-320H(320g/0.001g)
UW220H UX220H(220g/0.001g)
TW223L TX223L (220g/0.001g)
BL-220H(220g/0.001g)
AUX320 AUW320 (320g/0.1mg)
AUW220 AUX220 AUY220 (220g/0.1mg)
ATX224 ATY224 (220g/0.1mg)
AUW120 AUX120 AUY120 (120g/0.1mg)
ATX124 ATY124 (120g/0.1mg)
TWC623L TXC623L (620ct/0.001ct)
ATX84(82g/0.1mg)
ATY64(62g/0.1mg)
AP125WD(120g/0.1mg)(52g/0.01mg) AUW220D(220g/0.1mg)(82g/0.01mg)
AUW120D(120g/0.1mg)(42g/0.01mg)
UW4200H UX4200H (4200g/0.01g)
TX4202L(4200g/0.01g)
TX3202L(3200g/0.01g)
BL-3200H(3200g/0.01g)
UW2200H UX2200H (2200g/0.01g)
TX2202L(2200g/0.01g)
BL-2200H(2200g/0.01g)
UW820S UX820S (820g/0.01g)
TXB622L(620g/0.01g)
BL-620S(620g/0.01g)
ELB600(600g/0.05g)
UW420S UX420S (420g/0.01g)
TXB422L(420g/0.01g)
BL-320S(320g/0.01g)
ELB300(300g/0.01g)
TXB222L(220g/0.01g)
ELB200(200g/0.01g)
ELB120(120g/0.01g)
~100g 100g~ 300g~ 500g~ 1kg~ 3kg~
AP135W(135g/0.01mg)
AP225WD(220g/0.1mg)(102g/0.01mg)
ATX324 ATY324 (320g/0.1mg)
AP324W AP324X AP324Y (320g/0.1mg)
AUW/AUX/AUY Series ATX/ATY SeriesAP Series (0.1mg model)
AUW-D SeriesAP Series (0.01mg model)
UW/UX Series
TW-N/TX-N/TXB Series
AP124W AP124X AP124Y (120g/0.1mg)
AP224W AP224X AP224Y (220g/0.1mg)
11
BL-320S(320 g/0.01 g)
ELB300(300 g/0.01 g)
UW420HV(420 g/0.01 g)
AUW220D(220 g/0.1 mg)(82 g/0.01 mg)
How to use
capacitymodelname
minimumdisplay
Dual range
Internal Calibrationmodel is in blue
Prod
uct Lin
eup
0.01g(10mg)
0.1g(100mg)
1g~ BW52KS BX52KS (52kg/1g)
BW32KS
BX32KS (32kg/1g)
ELB12K(12kg/1g)
TXB6200L(6200g/1g)
ELB6000S(6000g/1g)
BW32KHBX32KH (32kg/0.1g)
BW22KH BX22KH (22kg/0.1g)
BW12KH BX12KH (12kg/0.1g)
UW8200S UX8200S (8200g/0.1g)
TXB6201L(6200g/0.1g)
UW6200H UX6200H (6200g/0.01g)
5kg~ 10kg~ 30kg~ 50kg~
UW/UX Series
BW-K/BX-K Series
TXB Series ELB Series
~100g 100g~ 300g~ 500g~ 1kg~ 3kg~
0.1g~ UW4200SUX4200S (4200g/0.1g)
TXB4201L(4200g/0.1g)
BL-3200S(3200g/0.1g)
ELB3000(3000g/0.1g)
TXB2201L(2200g/0.1g)
ELB2000(2000g/0.1g)
ELB1200(1200g/0.1g)
ELB600S(600g/0.1g)
ELB Series
BL Series
12
Product LineupProd
uct Lin
eup
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
AUW-DAUW
○
○
○
○
△*
○
○
○
○
ATXATYAUX
○
○
○
○
○
○
○
○
○
○
○
○
○
○
AUY
○
○
○
○
○
○
○
○
○
AP-Y
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
AP-X
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○ :Standard function
△ :Option
*Requires optional I/O-RS conversion cable or interface IFB-102A.
(AUW only)
(ATX only)
AP-WDAP-W
UniBloc
Perfect Self Calibration
Clock-CAL
Internal Calibration
Single-Lever CAL
Built-in Clock
ISO Calibration Report
Menu Operation Key
Easy Setting
Backlight
Organic EL Display
Balance Keys
Built-in RS-232C Interface
Built-in USB Interface
Analog Bar Graphic Display
Checkweighing
Comparator Output
Piece Counting
Carat Measurement
Specific Gravity Measurement
Dry Battery Operation
Standard Below-weight Hook
Built-in Animal Measurement Mode
Formulation Mode
Internal Timer Output
fabcdi
LM
gu1O P
564
.
BalanceKeys
13
Prod
uct Lin
eup
BW-KBX-K
MOC63uMOC-120H
TWTXUW
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
UX
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
TXB
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
△
○
○
○
BL
○
△*
○
○
○
○
○
○
○
○
○
○
○
ELB
△*
○
○
○
△
(TW-N only)
(BW-K only)
(MOC63u only)
UW-V
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
*1 Al l models : USB-B type connector as standard AP-W Ser ies: USB-A type and B type as standard
H i g h S p e e dThe response time for trace measurements (from 1 mg) is reduced to about 2 seconds.This significantly improves weighing efficiency.
S t r e s s F r e eThe STABLO-AP ionizer can be mounted. This eliminates the influence of static electricity, achieving reliable measurements in a simpler procedure.
Fo r H P LCFunctions are included for the preparation of buffer solutions used in HPLC.As a result, the operation can be performed accurately and easily, even by non-specialists.
S a v e Yo u r O p e r a t i o nEquipped with USB as standard*1. Includes many diverse functions to support users.
Fo r R e g u l a t i o nInterlocking with LabSolutions Balance enables compliance with a variety of regulations for measurement data integrity, including ISO 17025 for testing laboratories, ISO 9001 and ISO 14001 for the manufacturing industry, and GLP/GMP and the United States Pharmacopeia (USP) for the pharmaceutical industry.
A P S e r i e sA d v a n c e d P e r f o r m a n c e U n i B l o c B a l a n c e s
P ro v i d e s H i g h - s p e e d R e s p o n s e a n d H i g h S t a b i l i t y
A N e w S t a g e i n A n a l y t i c a l B a l a n c e P e r f o r m a n c e
14
AP Series | 0.01 mg to 0.1 mg | Analytical BalancesAP Series
|
0.01 mg
to 0.1 m
g |
An
alytical Balan
ces
* AP224W with optional ionizer
Watch the AP overview video on our website.
http://www.shimadzu.com/an/balance/analytical/ap.html
1
An
alytical Balan
ces
15
AP Series
|
0.01 mg
to 0.1 m
g |
An
alytical Balan
ces
AP Series | 0.01 mg to 0.1 mg | Analytical Balances
High Speed Fast measurement significantly
improves operational efficiency.
Fast Response with UniBloc AP Technology
Shimadzu analytical balances boast a one-piece UniBloc weighing sensor, which is now
even more advanced.
The response time is reduced to about 1/5 the time of previous models.
The improved UniBloc sensor offers a response time of just 2 seconds, an improvement
from 10 seconds with the previous model.
Response During Trace Measurements with the 0.01 mg Model(Equivalent to 1 mg / With Conditions Set by Shimadzu)
AP225WD (New model)
Indi
catio
n [m
g]
AP225WD approx. 2 sec.
10 2 3 4 5 6 7 8 9 10 11 120.0
0.2
0.4
0.6
0.8
1.0
1.2
Time [sec.]
AUW220D (Previous model)
AUW220D approx. 10 sec.
Response During Trace Measurements with the 0.1 mg Model(Equivalent to 1 mg / With Conditions Set by Shimadzu)
AP324W (New model)
0 1 2 3 4 5 6 7 8 9 10 11 12
AUX320 approx. 7 sec.AP324W approx. 1.5 sec.
Indi
catio
n [m
g]
0.0
0.2
0.4
0.6
0.8
1.0
1.2
Time [sec.]
AUX320 (Previous model)
Model
0.01 mg
0.1 mg
AP Series
2 sec.
1.5 sec.
Previous Model
10 sec.
7 sec.
* AP135W
Advanced Digital Control for Fast, Reliable Weighing
The improved measuring feel provides more comfortable use.
AP-i System (intelligent - Advanced Processing System)
Detects variations in weight
Digital control
High-speed control!Calculates weight signal!
Weight signal + Noise +External disturbances
Smoothing
Cuts noise andexternal disturbances!
Weight signal
Measuring feel has been significantly improved by using the advanced digital control technology and smoothing technology.
AP-i system provides reliable weighing even in an environment with significant external disturbances. This promises to increase the
efficiency of your measurement operations.
16
Stress Free A variety of accessories and options suitable
for semi-micro measurements
1
An
alytical Balan
ces
The multi stand can be used freely and easi ly.(0.01 mg model only, equipped as standard)
With weighing paper, for example, if the tare is larger than the pan diameter, measurements can be simplified by attaching the special multi stand.
Measuring weights with a pipette can be simplified by placing a micro tube upright in the sample holder in the special multi stand.
Long rod-shaped samples can be measured in a stable state by placing them in the slot in the special multi stand.
The internal windbreak plate suppresses the influence of convection and airflow within the weighing chamber, improving the stability and response of measurement values.
Built- in High-Performance Ionizer (Optional)
The ionizer eliminates influence of static electricity in 1/10the time of previous models.Note: Example of typical static electricity removal time (±1000 V ±100 V) 1 sec. for STABLO-AP and 10 sec. for STABLO-EX
AC Method with Excellent Ion Polarity BalanceMount the STABLO-AP in the balance and use it as a built-in model
Comparison of Neutralization Speed (Representative Values) STABLO-APPrevious model
Stat
ic C
har
ge
Vo
ltag
e (V
)
1000
900
800
700
600
500
400
300
200
100
0
Faster Neutralization
10 timesQuicker
0 2 4 6 8 10 12 14 16 18 20
Neutralization Time (sec.)Measurement Conditions• Time from ±1000 V to ±100 V• For this evaluation, a 150 × 150 mm charged plate monitor (CPM, 20pF) was used.
• Distance between CPM and ionizer: 100 mm
17
18
Buffer Solut ion Preparat ion Mode (AP-W Series only)
•Recipes for 13 commonly used buffer solutions are included as standard Preparation recipes for commonly used buffer solutions are provided as standard.
e.g. disodium phosphate, sodium acid citrate
•New buffer solution recipes can be registeredIf a buffer solution is not registered by default, it can be newly registered.
•Instructions are shown on the displayThe target weighing value is shown on the display and analog bar in order to compare the target with the current weight. Manual calculation is
not needed.
•Record functionRecord output with date, time and operator name.
The pH level of mobile phase (eluent) solutions used in liquid chromatographs is adjusted to improve separation of components and extend the
life of columns. This pH adjustment process is performed using a buffer solution. Currently, the most common method is using a pH meter to
measure the pH as the solution is prepared; however, this process requires considerable time and effort, which can cause operational bottlenecks.
An alternative method does not require a pH meter. It involves preparing solutions by weighing fixed theoretically calculated quantities of an acid
and base.
AP series supports weighing these acids and bases. If the type and quantity of the buffer solution are specified, the balance displays the type and
quantity of sample that should be weighed. Then the buffer solution can be prepared easily by adding water to the specified quantity of sample
weighed accordingly.
Preparation example: When weighing and preparing 50 mM of di-sodium hydrogen phosphate, 2-hydrate and 50 mM of sodium
dihydrogenphosphate, 2-hydrate in order to prepare 3 L of 100 mM phosphoric acid (sodium) buffer solution at pH=2.1:
Example of preparation by AP series
Select the buffersolution mode.
Specify the typeand quantity.
Displays the nameand quantity of sample.
Prepare as instructedon screen.
Complete buffer solution
* Results can be printed with date/time and user ID.
Number
1
2
3
4
5
6
7
8
9
10
11
12
13
Buffer solution preparation list
100mM
10mM
50mM
100mM
10mM
20mM
20mM
10mM
10mM
20mM
100mM
100mM
100mM
phosphoric acid (sodium)
phosphoric acid (sodium)
phosphoric acid (sodium)
phosphoric acid (sodium)
phosphoric acid (sodium)
citric acid (sodium)
citric acid (sodium)
tartaric acid (sodium)
tartaric acid (sodium)
acetic acid (ethanolamine)
acetic acid (sodium)
boric acid (potassium)
boric acid (sodium)
pH = 2.1
pH = 2.6
pH = 2.8
pH = 6.8
pH = 6.9
pH = 3.1
pH = 4.6
pH = 2.9
pH = 4.2
pH = 9.6
pH = 4.7
pH = 9.1
pH = 9.1
AP Series | 0.01 mg to 0.1 mg | Analytical BalancesAP Series
|
0.01 mg
to 0.1 m
g |
An
alytical Balan
ces
For HPLC For Users of HPLC Systems
1
An
alytical Balan
ces
19
Sample Preparat ion (AP-W Series only)
When preparing a standard solution from a particular component, the standard powder for this component will be a hydrochloride or a hydrate.
Preparing a standard solution of the target component at a desired requires difficult calculations prior to weighing it. With the AP series,
however, the required weight value is automatically calculated, so it can be weighed without performing manual calculations.
Example of preparation by AP series
Weigh 25 mg Amitriptyline to make a standard solution
Standard sample of Amitriptyline is Amitriptyline Hydrochloride.
Calculation is essential to determine part of Acidum hydrochloricum by molecular weight in order to
make a 100 mg/mL Amitriptyline solution.
Molecular weight of Amitriptyline: 277.4
Molecular weight of Acidum hydrochloricum: 36.5
Molecular weight of Amitriptyline Hydrochloride: 277.4 + 36.5 = 313.9
To compare the molecular weight of Amitriptyline Hydrochloride with Amitriptyline, the following
calculation is necessary.
313.9/277.4 = 1.132
The molecular weight of Amitriptyline Hydrochloride is 1.132 times of Amitriptyline.
So, if 25mg of Amitriptyline is used, it follows that the weight of Amitriptyline Hydrochloride should be:
25 mg × 1.132 = 28.3 mg.
Hence, 28.3 mg of Amitriptyline Hydrochloride is needed to make the correct standard solution.
Standard solution of Amitriptyline
Amitriptyline100 mg
1 mL
Amitriptyline Hydrochloride
AmitriptylineMolecular weight
277.4
Acidum hydrochloricumMolecular weight
36.5
No need for manual calculation
AP series can automatically calculate the sampling weight using the molecular amount of the standard sample, molecular
weight of unnecessary sample, and the target value in order to reach the correct concentration solution.
Just weigh the target weight value on display and the target weight of the standard sample can be obtained.
Target weighing value
Current sample value
Standard sample value
"OK" mark shown when target weight is reached.
Checking weighing conditions on the same display
20
*1 AP-W Series only
USB Offers Greater Expandabi l i ty (USB host: AP-W Series only)
Equipped with an RS-232C connector, a USB device and a USB host as standard. You can now
simultaneously send output to both a computer and printer or connect a USB flash drive, a
barcode reader, or an external numeric keypad.
Transcription errors can be avoided and data can be recorded without a computer.USB and RS-232Care standard
USB host is availablefor AP-W Series
Display capture functionWeighing display can be recorded into USB memory in BMP format. User name,
date/time, and setting can be shown with display information.
The user name, time, measurement conditions, pass/fail judgments, and other
information displayed on screen can be saved as is, enabling the recording of
measurements, and checks after measurements.
Numeric keypadConnecting a common external numeric keypad makes it easier to enter numeric values. This is especially
useful for entering the mass value of weights, setting upper/lower limit values for the comparator function, or
entering the sample count during piece counting mode.
Barcode readerA barcode reader can be connected. Simply reading a barcode makes it possible to input user ID/Password. It is
possible to manage sample IDs using barcodes.
An example of login by barcode
User001User ID card
LOGIN 01LOGIN 001
USB Connect
Can log in as User001
User002User ID card
LOGIN 02
User003User ID card
LOGIN 03
An ID and password are needed to log in to the AP series if protected access is activated. With the barcode, an operator can log in by scanning
the barcode instead of inputting an ID and password.
* The latest information can be seen from the Shimadzu website (http://www.shimadzu.com/an/balance/)
USB flash driveConnecting a USB memory device allows you to record large amounts of weighing data in CSV format. Used in
combination with the interval output function, it also enables recording of long-term changes over time.
Example of a record:File nameDate and timeWeighing value
*The information saved will differ depending on the function used.
AP Series | 0.01 mg to 0.1 mg | Analytical BalancesAP Series
|
0.01 mg
to 0.1 m
g |
An
alytical Balan
ces
Save Your Operation Equipped with USB as standard.*1
Includes many diverse functions to support users.
1
An
alytical Balan
ces
21
Easy-to-Read Organic EL Display (All models)
Because the pixel elements in the organic electroluminescence display emit light, the screen can be seen clearly even in dark locations.
Multi-language display capability*2 provides a more intuitive operating interface. A wider viewing angle has also improved the visibility of
measurement values, which helps increase the efficiency of measuring operations.
*2 Japanese, English and Chinese
Clearly visible from the side
English example
Exceptional Visibility
The visibility remains the same even when viewed from different angles. The viewing angle is a wide expanse of ±85 degrees, both vertically and
horizontally. That means the display is clearly visible even when working beside the balance. A high-resolution dot-matrix display makes it easy to
read detailed text.
Per iodic Inspect ion Support Funct ion (AP-W/AP-X Series only)
AP series supports periodic inspections. The function allows inspection of repeatability, corner
load error, and linearity by simply following instructions displayed on the screen.
Example of printing
Select the inspection mode.
In this case, repeatability inspection is selected.
Place standard weights as instructed.
Results are displayed.
Printing sample
IL: Loaded weightI0: Zero value
22
High-Secur i ty User Management (All models)
Operations can be kept secure with user ID and password protection. Access rights can be
specified separately for each user to prohibit unauthorized actions such as performing
calibration or changing the settings. User IDs can also be used for barcode management.
User Selection Screen
Pr int ing Data in Accordance with Var ious Regulat ions (All models)
Printing can be customized to indicate when the measurements were taken
and by whom. Users are free to set which items are to output, and in what
order. The date, time, calibration log, and other information can be printed
depending on the purpose of printing, which supports compliance with ISO,
GLP, and GMP.
<Printed content>
• Date
• Time
• User name
• Balance manufacturer name
• User ID
• Serial number
An example of printingTitle of result
Manufacturer name
Model name
Serial number
Date
Time
User name
Standard weight value
Weighing value before calibration
Weighing value after calibration
Signature
Minimum Measurement Value (Warning Funct ion) (All models)
Reproducibility can be confirmed by repeatedly measuring weights as instructed by AP
series. The minimum sample quantity is automatically determined from the standard
deviation and recorded in AP series.
If the minimum sample quantity requirement is not satisfied during measurement, an
indicator flashes to warn the user. Minimum sample quantity
Recipe Funct ion (AP-W Series only)
Sample recipes can be registered, allowing users to simply follow displayed instructions. This is convenient when compounding medicines.
• Balance ID
• Software version
• Minimum sample quantity
• Blank line
• Ruled line (--------)
(Achieve Your Preferred Compounding Process)
AP Series | 0.01 mg to 0.1 mg | Analytical BalancesAP Series
|
0.01 mg
to 0.1 m
g |
An
alytical Balan
ces
For Regulation For the Pharmaceutical Industry
1
An
alytical Balan
ces
23
Smart Sett ings (All models)
Response and stability settings can be changed during measurements with a single touch. Changing the settings for different applications can make
it even easier to use.
The indicator is operated using the left and right arrow keys. Moving the setting toward [R] prioritizes response, which
makes it easier to operate the balance. Conversely, moving it toward [S] makes it easier to stabilize weight values,
which can improve readability in environments with vibration.
User-friendly arrow keys Moving it left prioritizes response and moving it right prioritizes stability. Five setting levels are available.
Patented
Specific Gravity Measurement (All models)
In combination with an optional specific gravity measurement kit, the balance can be used to measure specific gravity. Operations are simplified
by a text-based navigation function. By using sinkers, the specific gravity of liquid can be measured as well. This allows measuring the specific
gravity of metals, rubbers, plastics, and other materials easily.
First measure the empty weight. Then place it in the container filled with water, as instructed on the screen.
The specific gravity value is displayed using simple steps.
PSC and Clock-CAL (AP-W/AP-X Series only)
A Perfect Self Calibration (PSC) function is included. The analytical balance automatically
detects any temperature changes that could affect sensitivity and automatically starts
calibration.
The Clock-CAL function enables automatic calibration at a pre-specified time (for example,
before starting work, during lunch, or after work hours).
Permissiblesensitivity error
Room temperature change
PSC (Perfect Self Calibration)
0
Roomtemp.
Sensitivityerror
8:00 a.m. 12:30 p.m. 5:00 p.m.
Automatically calibrate sensitivity at timesspecified by the Clock-CAL function.
Clock-CAL
And more... Wide Variety of Functions to Support Users
24
X Series / Y Series Analytical Balances
Series X Series Y Series
Model AP124X AP224X AP324X AP124Y AP224Y AP324YCapacityMinimum DisplayCalibration WeightExternal Calibration Weight Range for Span CalibrationRepeatability (Standard deviation)Repeatability (for Low Loads)
Minimum Weight*1
LinearityResponse Time for race Measurements *2
Response Time*3
USB Host (Type A)USB Device (Type B)Recipe CompoundingHPLC Buffer Solution Preparationmol Conversion FunctionSample (Concentration) PreparationInspection Support FunctionClock-CALIonizerOperating Temperature/Humidity RangeSensitivity Stability Against Temperature RangePan SizeBody DimensionsWeightDisplayInput/Output Terminal
120 g 220 g 320 g 120 g 220 g 320 g0.1 mg
Built-in No45 to 120.009 g
(100 g)95 to 220.009 g
(200 g)95 to 320.009 g
(300 g)45 to 120.009 g
(100 g)95 to 220.009 g
(200 g)95 to 320.009 g
(300 g)0.1 mg 0.15 mg 0.1 mg 0.15 mg
0.1 mg(5 g low loads)
0.1 mg(10 g low loads)
0.1 mg(20 g low loads)
0.1 mg(5 g low loads)
0.1 mg(10 g low loads)
0.1 mg(20 g low loads)
200 mg±0.2 mg ±0.3 mg ±0.2 mg ±0.3 mg
2 sec.2 sec.
Not IncludedIncluded
Not IncludedNot Included
Not Included
Included
Included
Not Included
Not IncludedIncludedOptional
Not IncludedNot Included
5 to 40°C 20 to 85%*4
±2 ppm/°C (10 to 30°C)ø91 mm
Approx. 212(W)×367(D)×345(H)mmApprox. 7.0 kg Approx. 6.5 kg
OEL display (dot matrix)RS-232C (D-sub9P plug) USB device (Type B) Ionizer RS-232C (D-sub9P plug) USB device (Type B)
*1 According to USP Chapter 41. This is the tested value by the weight of the balance’s capacity of 5%.
*2 The response time for displaying 90% of added sample amount value in trace measurements (from 1mg)
*3 The response time value is typical.
*4 Non-condensing.
CapacityMinimum DisplayCalibration WeightExternal Calibration Weight Range for Span CalibrationRepeatability (Standard deviation)Repeatability (for Low Loads)
Minimum Weight*1
LinearityResponse Time for race Measurements *2
Response Time*3
USB Host (Type A)USB Device (Type B)Recipe CompoundingHPLC Buffer Solution Preparationmol Conversion FunctionSample (Concentration) PreparationInspection Support FunctionClock-CALIonizerOperating Temperature/Humidity RangeSensitivity Stability Against Temperature RangePan SizeBody Dimensions
WeightDisplayInput/Output Terminal
W Series Analytical Balances
Model
Series W Series
AP125WD AP225WDAP135W120 g / 52 g 220 g / 102 g
0.01mg 0.1 mg / 0.01 mgBuilt-in
IncludedIncludedIncludedIncludedIncludedIncludedIncludedIncludedOptional
45 to 135.0009 g 45 to 120.0090 g 95 to 220.0090 g(100 g) (100 g) (200 g)
30 mg
0.015 mg(5 g low loads)
0.1 mg / 0.02 mg 0.1 mg / 0.05 mg0.05mg 0.1 mg
±0.2 mg±0.1 mg ±0.2 mg /±0.1 mg±0.2 mg /±0.05 mg
8 sec. 2 sec. / 8 sec.
5 to 40°C 20 to 85%*4
±2 ppm/°C (10 to 30°C)ø91 mm
Approx. 212(W)×411(D)×345(H)mm(power supply unit included)
Approx. 212(W)×367(D)×345(H)mm
Approx. 7.0 kgApprox. 7.9kgOEL display (dot matrix)
RS-232C (D-sub9P plug) USB host (Type A) USB device (Type B) Ionizer
AP324W320 g
AP224W220 g0.1 mg
AP124W120 g
95 to 320.009 g(300 g)
0.15 mg
0.1 mg(20 g low loads)
±0.3 mg
95 to 220.009 g(200 g)
0.1 mg(10 g low loads)
200 mg
2 sec.2 sec.
45 to 120.009 g(100 g)
0.1 mg(5 g low loads)
135 g
AP Series | 0.01 mg to 0.1 mg | Analytical BalancesAP Series
|
0.01 mg
to 0.1 m
g |
An
alytical Balan
ces
AP Series Specifications
1
An
alytical Balan
ces
25
AP135W (0.01 mg)AP125WD(0.01 mg / 0.1 mg)AP225WD(0.01 mg / 0.1 mg)
AP124WAP224WAP324W
0.01 mg / 0.1 mg model 0.1 mg model
AP124XAP224XAP324X
AP124YAP224YAP324Y
STABLO-AP Ionizer
*Power supply unit included.
Internal Windbreak PlateSMK-601
Specific Gravity Measurement Kit
EP-100 Electronic Printer EP-110 Electronic Printer(multifunction printer with liquid crystal display)
Options
Options
AP135W (0.01 mg)AP125WD(0.01 mg / 0.1 mg)AP225WD(0.01 mg / 0.1 mg)
0.01 mg / 0.1 mg model
*Power supply unit included.
Options
AP Series
Static Electricity Remover STABLO-AP Ionizer
Electronic Printer EP-100
Electronic Printer EP-110 (Multifunction Printer with Liquid Crystal Display)
Label Roll Paper for EP-100/110 (10 Rolls)
Specific Measurement Kit SMK-601
Display Protective Cover (Set of 5)
USB Cable
RS-232C Cable
AC Adapter (Standard Accessory)
Internal Windbreak Plate
RSIO Interface Cable
26
What is “ion balance”?
AC method
Concept of static removal
: Effective area
DC method
AC method: AC voltage is applied on the discharge needle and a well-balanced mixture of positive/negative ions is emitted in rapid alternation from one electrode.DC method: DC voltage is applied to a couple of electrodes. One is positive and the other is negative. Each electrode emits ions of one polarity only. An effective static removal angle is limited if the two electrodes are distanced. As electrodes deteriorate, initial ion balance is lost.
With the high-frequency AC corona discharge method, Shimadzu’s STABLO-AP ionizer provides a stable ion balance and excellent static removal performance on samples and containers.Precision weighing work becomes remarkably efficient.Electrodes are safely housed inside the unit.
Not neutralized (negative charge remains)
Sample Sample
Inversely charged (results in positive charge)
Electrod
e
Example: negatively charged sample
1
Negative static charge is neutralized by positive ions.
5
Well-balanced mixture ofpositive/negative ions areemitted in rapid alternation.
2
AC coronadischarge
Ions are appliedto sample3
Only the opposite charge ions are attracted.
4
If ion balanceis poor……
Ion balance is the balance of positive and negative ions that are supplied by an ionizer.If ion balance is poor, static electricity is not removed or inverse charging may result.
AC Method Produces Excellent Ion Balance
Static Electricity Removal by Ion Irradiation
on bbaalannnceeoor……………
Electrod
es
F e a t u r e s o f
STABLO-AP provides reliable measurement by removing static electricity.
— an excellent solution against
static electricity.
AC corona discharge method enables excellent ion polarity balance Wide angle static removal High performance maintained over a long period of use No inverse charging Shimadzu's unique 3-Way Ionizer: hand-held / on stand
Shimadzu’s unique3-Way positioning
Hand-held/On stand
Compar i son of S ta t i c Remova l T ime (Typical Examples)
Static Removal Time (sec)
1000
900
800
700
600
500
400
300
200
100
0
STABLO-APPrevious model
0 2 4 6 8 10 12 14 16 18 20
Measurement Conditions · Time from ±1000 V to ±100 V · 150 × 150 mm CPM (20 pF) used · Distance between CPM and ionizer: 100 mm
Stat
ic C
har
ge
Vo
ltag
e (V
)
Quicker!
10 timesQuicker
Static Remover (Ionizer)Shimadzu's proprietary 3-Way ionizer foranalysts troubled by static charging of samplesor containersOne-touch attachment and removal adds evenmore convenience
Special 3-Way Ionizer for Electronic Balances
STABLO-APSTAB
LO-AP
| Static Rem
over (Ionizer)
1
27
Ion Generation Method
Ion Balance
Effective Static Removal Range
Static Elimination Time (approx.)
Ozone Concentration
Electrode Probes
Weight
Operating Temperature and Humidity
Rated Electric Power Supply
AC corona discharge method
±10V
Approx. 400 mm from the outlet
1 second (Typical value) (from ±1000 V to ±100 V)
0.06ppm
Tungsten (durability: 30,000 hours)
Approx. 710 g (Main unit: 395 g, Stand: 315 g)
0 ºC to + 40 ºC, 25 % RH to 85 % RH (non-condensing)
DC 24 V, 1.0 A
Model name STABLO-AP
When the powder in the Petri dish iselectrically charged, and the numericalvalue fluctuates
When the powdered medicine paper iselectrically charged, and the numericalvalue is unstable
When the measurement spoon iselectrically charged, and bringing it nearthe pan affects the numerical value
Static electricity keeps the sample out of the ampoule
Plastic wrap sticks to rubber gloves
Plastic wrap adheres to rubber gloves,making it difficult to work with.
Fasten STABLO-AP to the stand, andremove the static from the gloves.
The static is removed in about 10 seconds,and the plastic wrap no longer sticks.
The sample is hard to handle because itadheres to the ampoule inlet and sides.
STABLO-AP removes the charge from theampoule.
The static charge is gone in seconds.This improves productivity.
BAD! GOOD!
BAD! GOOD!
Mount the STABLO-AP in the balance and use it as a built-in model
Application
STABLO-AP is convenient when using an electronic balance
Static Rem
over (Io
nizer)
Specifications
l
28
Analytical Balances
AUseries
Multi Functional Analytical Balance
AUW-D/AUX/AUY Series AUW Series
AU Series | 0.01 mg to 0.1 mg | Analytical BalancesAU
Series |
0.01 mg
to 0.1 m
g |
An
alytical Balan
ces
UniBloc Analytical BalancesAUW-D series dual-range semi-micro balancesAUW/AUX/AUY series analytical balances
Excellent Weighing PerformanceCompact UniBloc mechanism and digital processing technology produce fast response and
stability at the same time.•
Shimadzu’s unique Balance Keys
(http://www.shimadzu.com/an/balance/balance_keys/index.html)
a standard feature.
Measurement results can be transmitted to Excel or other Windows applications without
installing any additional software on your computer. All you have to add is one RS-232C
cable.
Piece counting, various mass units, below-weigh hook, specific gravity measurement
software are all standard features.
•
•
Excellent response, stability and zero return performance – in a semi-micro balance.
Choose one of the two models according to your field requirements.
Data can be automatically output at time intervals set in the range from 1 second to 99 minutes 59 seconds. This function can be also combined with WindowsDirect. (AUW-D/AUW/AUX models)
Interval Timer4
Calibration report can be automatically printed using an optional electronic printer. Date and time are also output to meet GLP/GMP/ISO requirements.
GLP/GMP/ISO calibration reportiOperator can choose from two fully-automatic span calibration methods. “PSC” is initiated based on temperature change detection, whereas “Clock-CAL” operates at user pre-set times (up to three times a day).
Restrainedsensitivity
error band
Ambient temperature change
Fully-automatic calibration
Sens
itivi
ty e
rror
0
Ambient temperature
Calibrations
SET
SET
SET8:00 12:30 17:30
All models a standard standard RS-232C interface for easy integration with other devices and computers.
RS-232C interface
SpecificGravity
Installing the optional SMK-401 specific gravity kit transforms the balance into a dedicated instrument for measuring specific gravity or density. Specific gravity measurement software is already installed in the Shimadzu balance.
Specific Gravity MeasurementChoice of fully-automatic calibrations: PSC and Clock-CAL
Automated calibration can be started by pressing keys. (AUW-D,AUW,AUX series)Also, your external calibration weights can be used for span calibration. (All models)
Touch-key calibration
In addition to piece counting, the balance can also perform measurements as percentages and in a variety of mass units, such as carat.
Piece Counting and Unit ConversionPCS
For Applications
1
An
alytical Balan
ces
29
AUW-DSeries
AUWSeries
AUXSeries
AUYSeries
AUSeries
Capacity
Minimum display
Pan size (mm)
Body Dimensions
Weight
Model nameAUW-D Series AUW Series AUY SeriesAUX Series
AUW220D AUW120D AUW320 AUW220 AUW120 AUX320 AUX220 AUX120 AUY220 AUY120
Application Keyboard AKB-301
Specific Gravity Measurement Kit SMK-401
STABLO-AP
80mm dia approx.
Approx. W220 × D330 × H310 mm
7 kg approx.
220 g/82 g 120 g/42 g 320 g 220 g 120 g 320 g 220 g 120 g 220 g 120 g
0.1 mg/0.01 mg 0.1 mg 0.1 mg 0.1 mg 0.1 mg 0.1 mg 0.1 mg 0.1 mg 0.1 mg
Optional Accessories
Electronic Printer EP-100
Electronic Printer EP-110
Specific Gravity Measurement Kit SMK-401
In Use Protection Cover
RS-232C Cable
USB Conversion Cable
Application Keyboard AKB-301
Foot switch FSB-102PK
Foot switch FSB-102TK
Description
Countermeasures for Static ElectricitySpecial 3-Way Ionizer for Electronic Balances
STABLO-AP
Description
Electronic Printer EP-100
Electronic Print Electronic Printer EP-110
er lectronic Printer El
30
Analytical Balances
ATseries
The balance has built-in motor-driven calibration weights.Sensitivity can be calibrated whenever needed by a single key press.
A built-in piece counting function enables balances to be used as parts counters (piece scales).
Internal Calibration (ATX only)
Piece Counting
Standard Models of Analytical Balances
b
This is convenient when formulating (preparing) multiple substances.
Formulation Mode6
Measures a percentage value with respect to a preset reference.
Percentage Measurement
AT Series | 0.1 mg | Analytical Balances
Economical Analytical BalanceEquipped with UniBloc
• Adopts UniBloc, which provides excellent impact resistance,
responsiveness, and stability
• Equipped with the Easy Setting function, so responsiveness and
stability can be adjusted during measurements
• Buy a separately available I/O-RS cable to import the results to a PC
(Equipped with the WindowsDirect function)
Indicator
Excellentresponsiveness
Excellentstability
• For super-fast measurements• For improved productivity• For measuring out and mixing fixed quantities of liquids and powders
• If the indicator is unstable i.e. When the work site is continuously subject to fairly strong vibrations• When continuous airflow often causes the indicator to fluctuate
AT Series
|
0.1 mg |
An
alytical Balan
ces
Smoothly!
Precisely!
Easy Setting
This displays pass, high, or low judgments.
Checkweighingu
1
31
ATXSeries
ATYSeries
I/O-RS conversion cable USB-serial adaptor
Optional Accessories
EP-100 Printer
EP-110 Printer
I/O-RS conversion cable
USB-serial adaptor
Protective cover (5 pcs)
AC adaptor (provided as standard with main unit)
Description
ATX/ATYSeries
Capacity
Minimum display
Pan size (mm)
Dimensions
Weight
Model
Approx. 91 dia.
0.1 mg
Approx. W213 × D356 × H338 mm
220 g
ATX224
120 g
Approx. 6.2 kg
ATX124
82 g
ATX84
220 g
ATY224
120 g
Approx. 6.0 kg
ATY124
62 g
ATY64
An
alytical Balan
ces
Countermeasures for Static ElectricitySpecial 3-Way Ionizer for Electronic Balances
STABLO-AP
Description
Electronic Printer EP-100
Electronic Prin Electronic Printer EP-110
I/O-RS nter ctronic PrinterElec
STABLO-AP
320 g
ATY324
320 g
ATX324
1
32 33
An
alytical Balan
ce
Shimadzu
BalancesM
od
el Nam
e
F l a g s h i p M o d e l s
AUseries
Analytical Balances
S t a n d a r d M o d e l s
ATseries
General PurposeAnalytical Balances
Functions
Clock function
Specific gravity measurement
Weigh below hook for hanging measurement
Backlight
Analog bar graph display
Interval timer output
320 g capacity
Piece counting
Clock-CAL
Built-in weights for sensitivity calibration
Formulation
Percentage measurement
UniBloc
Measurements in semi micron range
Perfect self sensitivity calibration
Functions
AUW-
D
AUW
AUX
ATX
ATY
AUY
Piece counting
Formulation
Built-in weights for sensitivity calibration
Easy Setting
Percentage measurement
Weight check
320 g capacity
UniBloc
Case material Aluminum die cast Case materialABS plastic
Weight checkIt is possible to measure out target mass, and display pass/fail judgments based on reference mass.
Built-in perfect self calibration (PSC) function (AUW-D, AUW, and AUX only)
Detects ambient temperature changes with an impact on sensitivity, and automatically performs sensitivity calibration.Built-in Clock-CAL function (AUW-D and AUW only)
These balances perform sensitivity calibration automatically at preset times.
■ Perfect self calibration (PSC)/ Clock-CAL functions are included
■ These balances have a built-in clock function. (AUW-D, AUW, and AUX only) Data can be logged with the date and time.This is ideal for establishing the measurement management and traceability required by GLP, GMP, and ISO 9000.
The optional SMK-401 is required.
The Easy Setting function eliminates troublesome settings.They can be used anywhere, at any time.
Five types of sample weight units can be registered.
For measurements down to 0.01 mg
For measuring counts of various samples
For measurements with referenceweights configured
For measuring specific gravity
For measuring samples 220 g or heavier
For consistently good precision
For balances that make weighing powdersand liquids easyFor use in environments subject to windand vibrationsFor selectable stability and response
Recommended
for the Following
Easy SettingEasy Setting
Weight checkWeight check
Clock function
Specific gravity measurement
Weigh below hook for hanging measurement
Backlight
Analog bar graph display
Interval timer output
Clock-CAL
Measurements in semi micron range
Perfect self sensitivity calibration
Clock function
Specific gravity measurement
Weigh below hook for hanging measurement
Backlight
Analog bar graph display
Interval timer output
Clock-CAL
Measurements in semi micron range
Perfect self sensitivity calibration
Analytical
The ATX/ATY seriesare recommendedThe AUW/AUX/AUY series
are recommended
For outputting changes in samplequantity over time
When a chemical resistant metallicbody is needed
For management of calibration recordsand measurement data by date and time
1
32 33
An
alytical Balan
ce
Shimadzu
Balances
Mo
del N
ame
F l a g s h i p M o d e l s
AUseries
Analytical Balances
S t a n d a r d M o d e l s
ATseries
General PurposeAnalytical Balances
Functions
Clock function
Specific gravity measurement
Weigh below hook for hanging measurement
Backlight
Analog bar graph display
Interval timer output
320 g capacity
Piece counting
Clock-CAL
Built-in weights for sensitivity calibration
Formulation
Percentage measurement
UniBloc
Measurements in semi micron range
Perfect self sensitivity calibration
Functions
AUW-
D
AUW
AUX
ATX
ATY
AUY
Piece counting
Formulation
Built-in weights for sensitivity calibration
Easy Setting
Percentage measurement
Weight check
320 g capacity
UniBloc
Case material Aluminum die cast Case materialABS plastic
Weight checkIt is possible to measure out target mass, and display pass/fail judgments based on reference mass.
Built-in perfect self calibration (PSC) function (AUW-D, AUW, and AUX only)
Detects ambient temperature changes with an impact on sensitivity, and automatically performs sensitivity calibration.Built-in Clock-CAL function (AUW-D and AUW only)
These balances perform sensitivity calibration automatically at preset times.
■ Perfect self calibration (PSC)/ Clock-CAL functions are included
■ These balances have a built-in clock function. (AUW-D, AUW, and AUX only) Data can be logged with the date and time.This is ideal for establishing the measurement management and traceability required by GLP, GMP, and ISO 9000.
The optional SMK-401 is required.
The Easy Setting function eliminates troublesome settings.They can be used anywhere, at any time.
Five types of sample weight units can be registered.
For measurements down to 0.01 mg
For measuring counts of various samples
For measurements with referenceweights configured
For measuring specific gravity
For measuring samples 220 g or heavier
For consistently good precision
For balances that make weighing powdersand liquids easyFor use in environments subject to windand vibrationsFor selectable stability and response
Recommended
for the Following
Easy SettingEasy Setting
Weight checkWeight check
Clock function
Specific gravity measurement
Weigh below hook for hanging measurement
Backlight
Analog bar graph display
Interval timer output
Clock-CAL
Measurements in semi micron range
Perfect self sensitivity calibration
Clock function
Specific gravity measurement
Weigh below hook for hanging measurement
Backlight
Analog bar graph display
Interval timer output
Clock-CAL
Measurements in semi micron range
Perfect self sensitivity calibration
Analytical
The ATX/ATY seriesare recommendedThe AUW/AUX/AUY series
are recommended
For outputting changes in samplequantity over time
When a chemical resistant metallicbody is needed
For management of calibration recordsand measurement data by date and time
34
Electronic Balances
UW/UXseries
Multi Functional Top-loading Balance
*Windbreak can be removed.UW4200SUW8200SUW2200HUW4200HUW6200H
UX4200SUX8200SUX2200HUX4200HUX6200H
UW420SUW820S
UX420SUX820S
UW220HUW420HUW620HUW820HUW1020H
UX220HUX420HUX620HUX820HUX1020H
The line of Shimadzu top-loading balances is engineered with the UniBloc mechanism, resulting in unrivaled response, stability and durability. Powerful features support any imaginable weighing application. The UW Series includes internal calibration and fully-automatic calibration functions.
The backlight LCD display can be clearly read in thedarkest of environments.
Backlight LCD
Just connect the optional printer to automaticallyoutput calibration results. Date and time aresupplied by the balance's built-in clock.
GLP/GMP/ISO Calibration Recordi
Calibration carried out at user-preset times (up to three times a day).Operators can work without unexpected interruptions.
When upper and lower thresholds are set, thebalance indicates if the sample weight is within therange (GO), over (HI) or under (LO).
Checkweighing Function
Restrainedsensitivity
error band
Ambient temperature change
Fully-automatic calibration
Sens
itivi
ty e
rror
0
Ambient temperature
Calibrations
SET
SET
SET8:00 12:30 17:30
A piece counting function is standard in addition tovarious unit conversions.
Piece CountingPCS
SpecificGravity
The standard specific gravity measurementcalculation function uses the Archimedes principle.Attaching the optional specific gravity measurementkit allows the balance to be used as a density meteror a hydrometer.
Specific Gravity Function
Data transfer port of UW/UX Series
Calibration is carried out when a temperature change has been detected.
PSC, fully-automatic calibration (UW only)
Clock-CAL, fully-automatic calibration (UW only)
Press just two keys to calibrate the balancewhenever calibration is necessary.
Automatic Touch-keyCalibration (UW only)
supplied by the ond time areclock.
cAko
on results. Date anbalance's built-in
UW/UX Series | 0.001 g to 0.1 g | Electronic BalancesUW
/UX
Series |
0.001 g to
0.1 g |
Electron
ic Balan
ces
35
UWSeries
UXSeries
UXSeries
220 g 420 g 620 g 820 g 1020 g 420 g
UX220H UX420H UX620H UX820H UX1020H UX420S820 g 2200 g 4200 g 6200 g 4200 g 8200 g
0.001 g 0.001 g 0.001 g 0.001 g 0.001 g 0.01 g 0.01 g 0.01 g 0.01 g 0.01 g 0.1 g 0.1 g
UX820S UX2200H UX4200H UX6200H UX4200S UX8200S
UWSeries
220 g
UW220H
0.001 g
420 g
UW420H
0.001 g
620 g
UW620H
0.001 g
820 g
UW820H
0.001 g
1020 g
UW1020H
0.001 g
420 g
UW420S
0.01 g
820 g
0.01 g
UW820S2200 g
0.01 g
UW2200H4200 g
0.01 g
UW4200H6200 g
0.01 g
UW6200H4200 g
0.1 g
UW4200S8200 g
0.1 g
UW8200S
2
Electron
ic Balan
ces
Capacity
Minimum display
Pan size (mm)
Model name
Capacity
Minimum display
Pan size (mm)
Model name
108 × 105 Approx. 170 × 180 Approx.
108 × 105 Approx. 170 × 180 Approx.
Optional AccessoriesElectronic Printer EP-100 / EP-110
RS-232C Interface IFB-102A (needed only for multiple connection)
Small Size Windbreak (for models with capacity of 300g to 620g only) (Std. Acc. for models with readability of 0.001g)
Glass Windbreak (for models with capacity of 220g to 820g only)
Large Size Windbreak (for all models)
Specific Gravity Measurement Kit SMK-101 (for Large size pan 170×180mm)
Specific Gravity Measurement Kit SMK-102 (for Small size pan 108×105mm)
Protective in-use cover for key panel and display (5 pcs)
Small Animal Bucket set (For large pan models only)
Angle Adjuster and Wall Hook for Remote Display
Stand for Remote Display (1m high)
Foot Switch FSB-102PK (For printing)
Foot Switch FSB-102PK (For taring)
RS-232C Cable, for IBM PC/AT Compatibles (25P-9P, Null modem, 1.5m)
RS-232C Cable, for multiple connections (25P-25P, Null modem, 1.5m)
Application Keyboard AKB-301
Remote Display Unit RDB-201 with operation keys
Remote Display Unit RDB-202
Large size windbreakWBC-502
Glass windbreakWBC-102
Application Keyboard AKB-301
Static Remover
STABLO-AP
Description
36
Electronic Balances
TW/TX/TXBseries
TW/TX/TXB Series | 0.0002 g to 1 g | Electronic BalancesTW/TX
/TXB
Series |
0.0002 g to
1 g |
Electron
ic Balan
ces
The beginning of the new standard.Extremely capable, but easy to operate.
Quickly adjust the desired ratio of stability andresponse for every application, even duringmeasurement, with one-touch operation.
Easy SettingBest fit to weighing application
Menu navigation keys are separated from weighing operation keys and arranged in a familiar 5-way navigation circle. Up, Down, Right, Left and Enter are the simple operational steps.
Menu Operation KeyEasy-to-operate Key Layout
Unit weights of up to five different samples can be easily entered, stored and recalled for use.
Expanded Piece Counting FunctionPCS
In addition to grams (g), weigh in %, number of pieces, ct, kg, mg, lb, oz, TTI, etc. or a custom conversion unit, more than 20 units in all. Change quickly from display of % or counting to gram weight (g) display.
Change among many weighing units and functions with a single touch
Compare samples to target values or pass/fail criteria and clearly indicate the results.
Comparator Function
Power the TXB series balances with an AC adaptor or batteries.
Can be used anywhere with battery power
Press just two keys to calibrate the balance whenever calibration is necessary (TW only). Calibration is very fast, taking only 15 sec.
Touch-key Internal Calibration
37
TWSeries
TXSeries
TXBSeries
TW223L TW323L TW423LTX223L TX323L TX423L
TWC323L TXC323LTWC623L TXC623L
TX2202L TX3202L TX4202L
TXB2201L TXB6201LTXB4201L TXB6200L
TXB222L TXB622LTXB422L TXB621L
TXBSeries
220 g 420 g
0.01 g 0.01 g
620 g 620 g 2200 g 4200 g 6200 g 6200 g
0.01 g 0.1 g
Approx. W199 × D260 × H77 mm
Approx 1.5 kg
0.1 g 0.1 g 0.1 g
ø110 ø110 ø160
1 g
TXB222L TXB422L TXB622L TXB621L TXB2201L TXB4201L TXB6201L TXB6200L
TWSeries
220 g 320 g
0.001 g 0.001 g
420 g 620 ct (124 g)320 ct (64 g)
0.001 g 0.001 ct (0.0002 g)
Approx. W206 × D291 × H241 mm
Approx ø110 Approx ø80
Approx 4.2 kg Approx 4.1 kg
TW223L TW323L TW423L TWC623LTWC323L
TXSeries
220 g 320 g
0.001 g 0.001 g
420 g 2200 g 3200 g 4200 g 320 ct (64 g) 620 ct (124 g)
0.001 g 0.01 g 0.01 g 0.01 g 0.001 ct (0.0002 g)
Approx. W167 × D181 Approx ø80Approx ø110
Approx 3.8 kg Approx 2.8 kg Approx 3.8 kg
Approx. W206 × D291 × H241 mm Approx. W206 × D291 × H241 mmApprox. W200 × D291 × H80 mm
TX223L TX323L TX423L TX2202L TX3202L TX4202L TXC623LTXC323L
2
Capacity
Minimum display
Pan size (mm)
Dimensions
Weight
Model name
Capacity
Minimum display
Pan size (mm)
Dimensions
Weight
Model name
Capacity
Minimum display
Pan size (mm)
Dimensions
Weight
Model name
Optional Accessories
EP-100 Printer
EP-110 Printer
RS-232C cable
In-use protective cover
In-use protective cover for display
USB conversion kit
Description
Electronic Printer EP-100
Electronic Print Electronic Printer EP-110
er lectronic Printer El
Electron
ic Balan
ces
38 39
Mo
del N
ame
Functions Functions
TW
TX
UniBloc
Built-in weights for sensitivity calibration
Piece counting
Peak hold
Capacity of 600 g/6 kg or more
Glass windbreak (Small pan models only) Glass windbreak (Small pan models only)
Interval timer output
Animal measurement mode
Weigh below hook for hanging measurement
Specific gravity measurement
Analog bar graph display
Backlight
Clock function
UW
UX
Case material Aluminumdie cast
Optional
Menu operation key
Easy Setting
UniBloc
Built-in weights for sensitivity calibration
Piece counting
Backlight
ABS plastic Case material
Perfect self calibration (PSC)
Clock-CAL
Five types of sample weight units can be registered.
For easy operation
When a glass windbreak is required
For measuring specific gravity
For weighing animals
When large-range capacity is required
Menu operation key
Easy Setting
Menu operation key
Easy Setting
Clock-CAL
Peak hold
Capacity of 600 g/6 kg or more
Interval timer output
Animal measurement mode
Weigh below hook for hanging measurement
Specific gravity measurement
Analog bar graph display
Clock function
Clock-CAL
Perfect self calibration (PSC)Perfect self calibration (PSC)
Peak hold
Capacity of 600 g/6 kg or more
Interval timer output
Animal measurement mode
Weigh below hook for hanging measurement
Specific gravity measurement
Analog bar graph display
Clock function
Shimadzu
Balances
F l a g s h i p M o d e l s
UW/UXseries
Electronic Balances
S t a n d a r d M o d e l s
TW/TXseries
General PurposeElectronic Balances
For registering multiple reference valuesfor piece counting
Recommended
for the Following
Electronic
The TW/TX seriesare recommended
The UW/UX seriesare recommended
When a chemical resistant metallicbody is needed
2
Electron
ic Balan
ces
The Easy Setting function eliminates troublesome settings.They can be used anywhere, at any time.
For balances that make weighing powdersand liquids easyFor use in environments subject to windand vibrationsFor selectable stability and response
■ These balances have a built-in clock function.Data can be logged with the date and time.This is ideal for establishing the measurement management and traceability required by GLP, GMP, and ISO 9000.
Perfect self calibration (PSC) function is included (UW only).
Detects ambient temperature changes with an impact on sensitivity, and automatically performs sensitivity calibration.Built-in Clock-CAL function (UW only)
These balances perform sensitivity calibration automatically at preset times.
■ Perfect self calibration (PSC)/ Clock-CAL functions are included
When perfect self calibration (PSC) andClock-CAL are required
When date and time output by thebuilt-in clock is required
38 39
Mo
del N
ame
Functions Functions
TW
TX
UniBloc
Built-in weights for sensitivity calibration
Piece counting
Peak hold
Capacity of 600 g/6 kg or more
Glass windbreak (Small pan models only) Glass windbreak (Small pan models only)
Interval timer output
Animal measurement mode
Weigh below hook for hanging measurement
Specific gravity measurement
Analog bar graph display
Backlight
Clock function
UW
UX
Case material Aluminumdie cast
Optional
Menu operation key
Easy Setting
UniBloc
Built-in weights for sensitivity calibration
Piece counting
Backlight
ABS plastic Case material
Perfect self calibration (PSC)
Clock-CAL
Five types of sample weight units can be registered.
For easy operation
When a glass windbreak is required
For measuring specific gravity
For weighing animals
When large-range capacity is required
Menu operation key
Easy Setting
Menu operation key
Easy Setting
Clock-CAL
Peak hold
Capacity of 600 g/6 kg or more
Interval timer output
Animal measurement mode
Weigh below hook for hanging measurement
Specific gravity measurement
Analog bar graph display
Clock function
Clock-CAL
Perfect self calibration (PSC)Perfect self calibration (PSC)
Peak hold
Capacity of 600 g/6 kg or more
Interval timer output
Animal measurement mode
Weigh below hook for hanging measurement
Specific gravity measurement
Analog bar graph display
Clock function
Shimadzu
Balances
F l a g s h i p M o d e l s
UW/UXseries
Electronic Balances
S t a n d a r d M o d e l s
TW/TXseries
General PurposeElectronic Balances
For registering multiple reference valuesfor piece counting
Recommended
for the Following
Electronic
The TW/TX seriesare recommended
The UW/UX seriesare recommended
When a chemical resistant metallicbody is needed
2
Electron
ic Balan
ces
The Easy Setting function eliminates troublesome settings.They can be used anywhere, at any time.
For balances that make weighing powdersand liquids easyFor use in environments subject to windand vibrationsFor selectable stability and response
■ These balances have a built-in clock function.Data can be logged with the date and time.This is ideal for establishing the measurement management and traceability required by GLP, GMP, and ISO 9000.
Perfect self calibration (PSC) function is included (UW only).
Detects ambient temperature changes with an impact on sensitivity, and automatically performs sensitivity calibration.Built-in Clock-CAL function (UW only)
These balances perform sensitivity calibration automatically at preset times.
■ Perfect self calibration (PSC)/ Clock-CAL functions are included
When perfect self calibration (PSC) andClock-CAL are required
When date and time output by thebuilt-in clock is required
40
BL Series | 0.001 g to 0.1 g | Top-Loading BalancesBL Series
|
0.001 g to
0.1 g |
Top
-Load
ing
Balan
cesELB
Series |
0.01 g to
1 g |
Portab
le Electron
ic Balan
ces
Top-Loading Balances
BLseries
Basic Top-Loading Balances
BLSeries
BL-320S BL-220HBL-320H
BL-620SBL-3200SBL-2200HBL-3200H
BLSeries
High-resolution balances made affordable
Piece counting function is standard.
Piece counting functionPCS
220 g 320 g 320 g 620 g 2200 g 3200 g 3200 g
0.01 g 0.01 g0.001 g0.001 g
W160 × D124W100 × D100
0.01 g 0.01 g 0.1 g
BL-220H BL-320H BL-320S BL-620S BL-2200H BL-3200H BL-3200SCapacity
Minimum display
Pan size (mm)
Model name
Data transfer port of BL Series
Optional Accessories
Electronic Printer EP-100
Electronic Printer EP-110
In Use Protection Cover
Description
Remaining weighing capacity can be seen at a glance.
Analog bar graph display
3
41
Basic To
p-Lo
adin
g B
alances
Portable Electronic Balances
ELBseries
ELB Series | 0.01 g to 1 g | Portable Electronic Balances
ELB120ELB200ELB300
ELB600SELB6000SELB600ELB1200ELB2000ELB3000ELB12K
300 g120 g
0.01 g
ELB120200 g
0.01 g
ø110
ELB200
0.01 g
ELB300600 g
0.05 g
ELB600600 g
0.1 g
ELB600S1200 g
0.1 g
ELB12002000 g
W170 × D130
0.1 g
ELB20003000 g
0.1 g
ELB30006000 g
1 g
ELB6000S12 kg
1 g
ELB12K
ELBSeries
Portable Electronic Balance
Precision without compromise
Battery operation makes it portable.
Two-way power supply(AC or Battery operation)
SpecificGravity
Optional specific gravity kit is available for extra efficiency.
Standard specific gravity software
Piece counting, percent display, and specific gravity modes are easily accessible.
Various application modesPCS
Capacity
Minimum display
Pan size (mm)
Model name
Optional Accessories
Electronic Printer “EP-100” “EP-110” (impact-dot print)
RS-232C Interface “IFB-102A”
Specific Gravity Measurement Kit “SMK-201” (except for ELB120,200,300 for rectangular-pan models only)
Carrying case
In-use protective cover
Below-weigh hook (except for ELB12K)
Description
Data transfer port of ELB Series
Easy battery replacement
Electronic Printer EP-100
Electronic Print Electronic Printer EP-110
er lectronic PrinterEl
42
Precision Platform Balances
BW-K/BX-Kseries
BW-K/BX-K Series | 0.1 g to 1 g | Precision Platform Balances
Electronic Printer EP-100
Electronic Print Electronic Printer EP-110
er lectronic Printer El
Precision Balance for Heavy Samples
BW-K
/BX-K
Series |
0.1 g to 1 g |
Precision Platform Balances
MO
C-120H
|
0.001 g / 0.01%
|
Mo
isture A
nalyzer
BW-KSeries
Hookassy for below weighing
BW12KH
BW-K/BX-KSeries
12 kg 22 kg 32 kg 32 kg 52 kg12 kg 22 kg 32 kg
0.1 g 1 g0.1 g0.1 g
W345 × D250
1 g0.1 g 0.1 g 0.1 g
BX12KH BX22KH BX32KH BX32KS BX52KSBW12KH BW22KH BW32KH32 kg 52 kg
1 g 1 g
BW32KS BW52KS
BX-KSeries
The Shimadzu Precision Platform balances have been engineered with the innovative UniBloc mechanism since 1989. Powerful features support any imaginable weighing application. The BW-K Series includes internal calibration weight.
Capacity
Minimum display
Pan size (mm)
Model name
*Below weighing is optional
Data transfer port of BW-K/BX-K Series
Optional Accessories
RS-232C interface IFB-102A (for multiple connections)
Electronic Printer EP-100/110
Foot Switch FSB-102PK (For printing)
Application Keyboard AKB-301
USB-SERIAL Conversion Kit
RS232C cable
Below-weigh hook
Description
Application KeyboardAKB-301
43
4
Moisture Analyzer
MOC-120HMoisture Analyzer with a Wide Sample Pan
MOC-120H
MOC-120H | 0.001 g / 0.01 % | Moisture Analyzer
Printer
Company nameModelSerial no.Instrument IDSample codeMeasurement date/timeMeasurement conditions storage areaMeasurement referenceMeasurement modeDrying temperatureAutomatic ending conditionsPredictive convergence range
Un-dried mass:
: Shimadzu Corporation: MOC-120H: D207300000: ABCD-123: B-20: 15:07 Aug. 8, 2007: 0: Dry basis moisture ratio: Comparative measurement: 110 ℃: 0.05 %: 0.5
: 5.6892 g
Measurement timeDrying temperatureMeasurement value (%)
Predicted measurement value
Dried mass : 4.8637 g
[Graph Format (GRP)]
Sample Output from Optional Printer
*1 Temperature calibration using the optional Temperature Calibration Kit may be necessary depending on the
measurement sample and the measurement conditions. Temperature calibration makes it possible to control
the drying temperature of the measurement sample more accurately.
Warning●Use this balance to heat samples to evaporate moisture for measurement.●The built-in heater will be hotter than the set temperature.●Samples must not be measured if there is a risk of an explosion or fire, or a dangerous chemical reaction from heating.
MOC-120H
Measurement method
Pan size
Minimum weight displayed
Moisture ratio measurement range
Minimum moisture ratio displayed
Maximum sample quantity
Measurement modes
Drying heat source
Temperature settings range
Unit dimensions and weight
Operational temperature and humidity range
Required power supply
Accessories
Model
Infrared heating/dry mass measurement
130 mm dia
0.001 g
0.01 to 100.00 %
0.01 %
120 g
Automatic operation mode, Timered operation mode, High-speed drying mode, Low-speed drying mode
Medium wave infrared quartz heater
30 to 200 °C (1 °C steps)
W220 × D415 × H190 mm 4.5 kg
5 to 40 °C, relative humidity of 85 % max.
100 to 120/220 to 240 VAC, 640 W max.
Sample pan × 2, pan holder, windbreak, sample pan tongs, aluminum sheet × 20, spatula
MOC-120H
Optional Printer and AccessoriesDescription
Printer set includes a connection cord and 1 roll of printer paper (thermal paper)
Printer paper (10 rolls)
Optional Accessories A Wealth of Accessories to Enhance Your Possibilities
Description
RS-232C cable
Sample pan
Aluminum sheets (500 pcs)
Temperature Calibration Kit*1
Protective display cover (5 pcs)
Measure the Moisture Ratio of Even Large orLarge Amounts of Samples• The moisture ratio is found by heating the sample with the built-in infrared heater.
• The sample pan measures 130 mm in diameter, which is optimal for large and large
amounts of samples.
• Importing results to a PC is easy (equipped with the WindowsDirect function).
• Equipped with the UniBloc aluminum block mass sensor.
Mo
isture A
nalyzer
Drying conditions during
measurement and the final
measurement value can be
graphed and printed out.
Moisture Analyzer
MOC63uEasy, Reliable Moisture Content Measurements
2
31
4
Generally, the wider, thinner, and more uniformly the sample is spread, the more precise the measurement. Uniform heating is provided by adopting a cleverly shaped reflector (patent pending).
This automatically ends measurement when the moisture change(% margin) over 30 seconds drops below a set value.
The sample is dried at the highest temperature for the initial drying stage, and when the moisture has been reduced, it returns to the set temperature, shortening the measurement time.
Rapid Drying Mode
This gently heats samples that might form a surface film or are prone to degrading at high temperatures.
Slow Drying Mode
Drying conditions are changed step by step for samples that contain a lot of moisture, such as surface water or crystallization water.
Step Drying Mode
Automatic Ending Mode
This automatically ends measurement after a preset amount of time (t1).
Timed Ending Mode
Ending Modes
Alternate Drying Modes
The sample pan size is a spacious 95 mm dia.
● A real-time indicator has been adopted, which blinks to show the measurement status.
● A cross-shaped key layout has been adopted for excellent operability.
● The results are shown as a percentage using an LCD, backlit to enhance visibility.
● Graphics are provided to let you confirm the pan status in real time.
1
2
3
4
This product is certified underShimadzu's Eco label system.Energy savings: 30 % reduction over previous Shimadzu models
A Total of Five Modes Makes This Balance Compatible with a Variety ofSample Measurements
The sample is easy to see!Wide observation window
Temp
erature
Temp
erature
Moisture vaporization
Moisture vaporization
Temp
erature
Moisture vaporization
Temp
erature
Moisture vaporization
Temp
erature
Moisture vaporization
Margin (%)
Automatic ending
Drying stops
5 min
Ending set time
t (time)
t (time)
t (time)
t (time)
t 1
T1
T2
T3
t 2 t 3
t1 (set time)
30sec
200℃
MOC63u | 0.001 g / 0.01 % | Moisture Analyzer
This Unit Makes Moisture ContentMeasurements Quick and Easy
• The moisture ratio is found by heating the sample with the built-in halogen
heater to drive out the moisture.
• The measurement procedure is simple. Just close the heater cover to start the
measurement (automatic starting mode).
• Measurements are faster than the loss on drying method using a dryer.
• A USB connector is standard, so connecting to a PC is easy (built-in
WindowsDirect function).
• Equipped with the UniBloc aluminum block mass sensor.
MO
C63u
|
0.001 g / 0.01 %
|
Mo
isture A
nalyzer
44
4
45
A USB connector is built in as standard for connecting to a PC. It can be used in conjunction with the WindowsDirect function.For Windows Vista, Windows 7, Windows 8 and USB port connections, check the Shimadzu website, or contact your Shimadzu representative.
Select the automatic starting mode, place the sample, and close the heater cover to start the measurements. The preparation for measurement is so simple that you do not even have to press the start key.
A Wealth of PC Connection Functions
Simple Operation
Warning●Use this balance to heat samples to evaporate moisture for measurement.●The built-in heater will be hotter than the set temperature.●Samples must not be measured if there is a risk of an explosion or fire, or a
dangerous chemical reaction from heating.
Sample Printout
ModelSerial no.Instrument IDSample codeDateTimeProgram no.Measurement referenceMeasurement conditionsDrying temperatureEnding conditions
Mass before measurement
Progressive measurementsElapsed measurement time:
Mass after measurement
:MOC63u:D209400009: 0000: 0040:Dec. 17, 2018: 16:27: 0:Wet basis moisture ratio:Automatic ending mode: 160 ℃: 0.05 %
: 5.161 g
Measurement value corresponding to themeasurement reference
: 4.747 g
Using the EP-100/EP-110
Compatible with printers (EP-100/EP-110).Equipped with I/O port.
Built-in RS-232Cinterface is standard.
Equipped with USB interface.Importing data to a PC is easy.
MOC63u
Mass
Moisture ratio
Repeatability *1
Method
Power
Temperature settings
Display
Pan size
Dimensions (mm)
Weight
Rated power
Ambient temperature
Measurement modes
Time settings
External output
Storage of measurement conditions
Data memory
Standard accessories
Model
60 g
0.02 g
0.001 g
0.01 %
0.15 %(2 g) 0.05 %(5 g) 0.02 %(10 g)
Halogen (straight tube)
Rated at 400 W
50 to 200 °C (1 °C interval) (up to 1 hour for settings over 180 °C)
Backlit LCD
95 mm dia
Approx. W202 × D336 × H157
Approx. 4.2 kg
430 VA
5 to 40 °C, relative humidity of 85 % max.
Standard drying mode (Automatic ending/timed ending)
Rapid drying mode (Automatic ending/timed ending)
Slow drying mode (Automatic ending/timed ending)
Step (3-stage) drying mode (Automatic ending/timed ending)
1 to 240 min, or continuous (up to 12 hours)
USB
Data I/O printer (EP-100/EP-110) output
RS-232C(D-sub9P)10 sets
100 items
Sample pans (3 aluminum pans), pan holder, windbreak, board,
aluminum sheets (50), pan handler, power cable, spare fuses (2),
protective display cover, hexagonal wrench
MOC63u Options A Wealth of Accessories to Enhance Measurement Possibilities
EP-100 Printer
EP-110 Printer
Protective display cover (5 pcs)
Aluminum pans (disposable) (50 pcs)
Fiberglass sheets (for liquid sample measurements) (100 pcs)
Temperature Calibration Kit
Sample pan (stainless steel) (5 pcs)
Sample pan (aluminum) (5 pcs)
RS-232C cable
USB cable set
Sample pan handler (stainless steel)
Halogen heater (for replacement)*2
Power cable
*2 The halogen heater can be removed and replaced by the user.Note: For delivery related matters, contact your Shimadzu representative.
*1 The repeatability (standard deviation) value is from a standard measurement (sample: sodium tartrate dihydrate). This value is not guaranteed for all samples, environments, and measurement conditions.
Capacity
MOC63u
Mo
isture A
nalyzer
Sample Measurement Results Output
Max. sample quantity DescriptionMin. sample quantity
Minimumdisplay
Heatsource
46
Moisture Analyzer
MOC63u Sample Applications
M e a s u r e m e n t o f M i l k
Measurement of Milk
Measurement conditions: 140 °C/TIME 10 minutes
87.7087.6187.6887.660.047
0.05
MOC63uSample mass (g) Moisture ratio (%)
1st2nd3rdAverageStandard deviationCV(%)
1.0811.0251.031
• Fiberglass sheets for liquid measurement were used to promote liquid evaporation.
• Two measurement conditions were used, timed ending and automatic ending modes.
Essentially, the same average values were obtained. With samples featuring a principal
component that has a relatively high evaporation temperature and also contains
moisture, the same results will be obtained regardless of the mode used.
(Before measurement) 1 g of milk was drippedon to a fiberglass sheet for liquid measurements.
(After measurement) The moisture hasevaporated from the milk, and the remainingfats have yellowed slightly.
The drying curve for milk in timedending mode is shown below.
M e a s u r e m e n t o f I n s t a n t C o f f e e
7.337.507.457.43
0.0871.18
MOC63uSample mass (g) Moisture ratio (%)
1st2nd3rdAverageStandard deviationCV(%)
0.9941.0790.980
• Commercially available powdered instant coffee was measured.
A sample of approximately 1 g was placed in the pan, and the pan was shaken to spread
the sample over the entire pan.
• Essentially no difference in the moisture ratio was evident in timed ending mode or
automatic ending mode. When a high drying temperature is set to shorten the drying
time, the radiant heat from the halogen lamp becomes significant, and sample surfaces
are sometimes scorched. Accordingly, with colored samples and samples prone to
degradation, it is better to set as low a drying temperature as possible.
(Before measurement) The sample was spreadevenly over the pan.
(After measurement) There was basically nodiscoloration.
The drying curve for instant coffee intimed ending mode is shown below.
Measurement of Instant Coffee
Measurement conditions: 120 °C/TIME 10 minutes
MOC63u | 0.001 g / 0.01 % | Moisture AnalyzerMO
C63u
|
0.001 g / 0.01 %
|
Mo
isture A
nalyzer
Photos of the milk before and after drying are shown below.
Photos of the instant coffee before and after drying are shown below.
Instant Coffee
Milk
Food
Food
4
47
Mo
isture A
nalyzer Sam
ple A
pp
lication
s
●Summary of Results Found for the Moisture Ratios of Baked Sweets Using Several Methods
Ground up baked sweets loaded in theMOC63u
Baked sweets removed from thethermostatic chamber
Fiberglass sheet coated withdengakumiso and loaded in the MOC63u
Dengakumiso removed from thethermostatic chamber
A summary of moisture ratios and measurement times in the official test method, timed ending mode, and rapid drying mode is shown below.
Moisture ratio
39.4 %37.2 %40.1 %
Measurement time
5 hours
1 hour
7 min 45 sec
Measurement method
Official test method
Timed ending mode
Rapid drying mode
Moisture ratio
7.6 %7.1 %7.8 %
Measurement time
5 hours
15 min
5 min 10 sec
Measurement method
Official test method
Timed ending mode
Rapid drying mode
Windows Direct
0.00
1.00
2.00
3.00
4.00
5.00
6.00
7.00
8.00
9.00
00.00.00 00.01.00 00.02.00 00.03.00 00.04.00 00.05.00Time(min)
Mo
istu
re C
on
ten
t(%
)
Windows Direct
0.00
5.00
10.00
15.00
20.00
25.00
30.00
35.00
40.00
45.00
00.00.00 00.02.00 00.04.00 00.06.00Time(min)
Mo
istu
re C
on
ten
t(%
)
M o i s t u r e C o n t e n t M e a s u r e m e n t o f B a k e d S w e e t s
• In the official test method, the drying period in a thermostatic chamber is five hours, so
more than five hours are required to obtain the moisture ratio results.
• When the sample was measured using a moisture analyzer (in timed ending mode) at
110 °C, 10 °C higher than the 100 °C drying temperature specified in the official method,
results similar to those from the official method were obtained with a drying time of 15
minutes.
• At 15 minutes in timed ending mode, the moisture ratio from the official test method is
not reached. However, a moisture ratio similar to that from the official test method can
be obtained if the drying time is set slightly longer.
M o i s t u r e C o n t e n t M e a s u r e m e n t o f D e n g a k u m i s o( f e r m e n t e d s o y b e a n p a s t e )
• In the official test method, the drying period in a thermostatic chamber is five hours, so
more than five hours are required to obtain the moisture ratio results.
• When the sample was measured using a moisture analyzer (timed ending mode) at 105
°C, the same temperature as specified in the official test method, results similar to those
from the official test method were obtained in about one hour.
• At one hour in timed ending mode, the moisture ratio from the official test method is
not reached. However, a moisture ratio similar to that from the official test method can
be obtained if the drying temperature is increased, or if the drying time is set slightly
longer.
●Summary of Results Found for the Moisture Ratios of Dengakumiso Using Several Methods
A summary of moisture ratios and measurement times in the official test method, timed ending mode, and rapid drying mode is shown below.
Drying curve for moisture ratio ofbaked sweets measured in rapiddrying mode (vertical axis: moistureratio; horizontal axis: time)
Drying curve for moisture ratio ofdengakumiso measured in rapiddrying mode (vertical axis: moistureratio; horizontal axis: time)
Food
Food
48
Rice seasoning loaded in the MOC63uRice seasoning removed from thethermostatic chamber
Ground up boiled fish paste loaded inthe MOC63u
Boiled fish paste removed from thethermostatic chamber
Moisture ratio
3.1 %2.5 %3.0 %
Measurement time
4 hours
15 min
3 min 35 sec
Measurement method
Official test method
Timed ending mode
Rapid drying mode
Moisture ratio
73.8 %69.7 %72.9 %
Measurement time
5 hours
1 hour
21 min 30 sec
Measurement method
Official test method
Timed ending mode
Rapid drying mode
Windows Direct
0.00
0.50
1.00
1.50
2.00
2.50
3.00
3.50
00.00.00 00.01.00 00.02.00 00.03.00Time(min)
Mo
istu
re C
on
ten
t(%
)
Windows Direct
0.00
10.00
20.00
30.00
40.00
50.00
60.00
70.00
80.00
00.00.00 00.05.00 00.10.00 00.15.00 00.20.00Time(min)
Mo
istu
re C
on
ten
t(%
)Moisture Analyzer
MOC63u Sample Applications
M o i s t u r e C o n t e n t M e a s u r e m e n t o f R i c e S e a s o n i n g
M o i s t u r e C o n t e n t M e a s u r e m e n t o fB o i l e d F i s h P a s t e
• In the official test method, the drying period in a thermostatic chamber is four hours, so
more than four hours are required to obtain the moisture ratio results.
• The sample was measured using a moisture analyzer at 110 °C, 5 °C higher than
specified in the official test method (timed ending mode). Despite the increased drying
temperature, the moisture ratio from the official test method was not reached at 1/4
the time from that test method.
• When the sample was measured in rapid drying mode to shorten the time, a value
similar to that from the official test method was obtained in 3 minutes and 35 seconds.
This is because heating the sample at 200 °C in step 1 caused immediate evaporation,
thereby promoting evaporation efficiency.
• In the official test method, the drying period in a thermostatic chamber is five hours, so
more than five hours are required to obtain the moisture ratio results.
• When the sample was measured using a moisture analyzer at 105 °C, the same
temperature as specified in the official test method, the results after a drying time of
one hour were slightly less than those from the official test method.
• At one hour in timed ending mode, the moisture ratio from the official test method is
not reached. However, a moisture ratio similar to that from the official test method can
be obtained if the drying temperature is set higher, or if the drying time is set slightly
longer.
●Summary of Results Found for the Moisture Ratios of Rice Seasoning Using Several Methods
A summary of moisture ratios and measurement times in the official test method, timed ending mode, and rapid drying mode is shown below.
●Summary of Results Found for the Moisture Ratios of Boiled Fish Paste Using Several Methods
A summary of moisture ratios and measurement times in the official test method, timed ending mode, and rapid drying mode is shown below.
MOC63u | 0.001 g / 0.01 % | Moisture AnalyzerMO
C63u
|
0.001 g / 0.01 %
|
Mo
isture A
nalyzer
Drying curve for moisture ratio ofice seasoning measured in rapiddrying mode (vertical axis: moistureratio; horizontal axis: time)
Drying curve for moisture ratio ofboiled fish paste measured in rapiddrying mode (vertical axis: moistureratio; horizontal axis: time)
Food
Food
4
49
The table below summarizes moisture rat io measurements for var ious samples using the moisture analyzer.
Dog food
Table salt
Instant coffee
Coffee beans (raw)
Coffee beans (roasted)
Green tea
Corn starch
Sugar (granulated sugar)
White rice
Mayonnaise
Orange juice
Milk
Chocolate
Rolled oats
Tomato ketchup
Frozen sweets
Dried mangoes
Palm oil
Hand soap
Lipstick
Plastic (PMMA pellet)
Photocopier paper
Sodium tartrate dihydrate
Detergent (powdered)
Solid soap
Water-based paint
Sludge cake
Potting soil
Sawdust
Baked sweets
Dengakumiso
Rice Seasoning
Boiled fish paste
Sake lees
Salted rice malt
Soy sauce
Miso
Sardine dumplings
Plastic (ABS pellet)
1 g
5 g
1 g
5 g
3 g
5 g
5 g
5 g
6 g
1 g
1 g
1 g
3 g
6 g
2.5 g
2.5 g
5 g
2.5 g
1 g
1 g
10 g
1 g
5 g
5 g
3 g
1 g
2 g
5 g
4 g
3 g
5 g
3 g
5 g
3 g
5 g
5 g
5 g
5 g
5 g
AUTO
TIME
TIME
AUTO
AUTO
AUTO
AUTO
AUTO
AUTO
TIME
AUTO
AUTO
AUTO
AUTO
AUTO
TIME
AUTO
TIME
AUTO
TIME
TIME
AUTO
TIME
AUTO
TIME
AUTO
AUTO
AUTO
AUTO
RAPID
RAPID
RAPID
RAPID
RAPID
RAPID
RAPID
RAPID
RAPID
TIME
0.05 %
10 min
10 min
0.05 %
0.05 %
0.05 %
0.02 %
0.05 %
0.05 %
10 min
0.05 %
0.05 %
0.01 %
0.05 %
0.1 %
12 min
0.05 %
5 min
0.05 %
3 min
25 min
0.05 %
15 min
0.05 %
16 min
0.05 %
0.05 %
0.05 %
0.05 %
3.0 % 0.1 %
2.0 % 0.1 %
2.0 % 0.01 %
1.0 % 0.01 %
1.5 % 0.01 %
2.0 % 0.05 %
1.0 % 0.01 %
2.0 % 0.05 %
0.5 % 0.02 %
12 min
160
200
120
140
140
120
180
160
200
160
140
140
140
200
140
140
120
120
200
100
100
200
160
160
200
200
200
120
160
Step 1 200Step 2 110
Step 1 200Step 2 110
Step 1 200Step 2 110
Step 1 200Step 2 105
Step 1 200Step 2 105
Step 1 200Step 2 115
Step 1 200Step 2 105
Step 1 200Step 2 115
Step 1 200Step 2 115
150
5:48
10:00
10:00
17:30
7:06
9:05
9:25
1:02
13:55
10:00
10:09
7:30
6:18
10:05
19:47
12:00
28:27
5:00
21:36
3:00
25:00
1:50
15:00
13:08
16:00
9:27
21:31
15:30
8:27
5:10
7:45
3:35
21:30
21:30
14:20
10:40
15:22
23:20
12:00
6.45
0.08
7.43
9.32
2.68
3.76
12.17
0.13
14.48
20.61
88.89
87.36
2.36
12.65
69.40
84.53
6.62
0.41
88.89
0.73
0.13
7.84
15.80
9.79
9.09
52.39
81.55
33.40
34.38
7.6
39.4
3.1
73.8
55.8
46.2
68.2
50.8
72.1
0.27
3.17
6.93
1.18
1.68
3.73
0.41
0.73
0.01
0.42
0.46
0.09
0.04
1.49
0.14
0.16
0.22
12.10
3.70
0.39
9.37
4.56
0.71
0.04
1.59
1.66
0.75
0.40
2.16
0.91
30.26
2.79
83.87
0.14
4.30
0.82
0.19
1.79
0.29
4.33
Note 1: Measurement times, moisture ratios, and CV (%) values are aggregated from three data cycles.Note 2: The CV (%) is the standard deviation divided by the average value, multiplied by 100 to represent it as a percent.
Measurement ModeSampleQuantity
Set Temperature(°C)
MeasurementTime (min)
MoistureRatio (%)
CV (%)Ending Conditions Finishing Conditions (% or min)
Moisture Analyzer
MOC63u Sample Applications
Step 1Step 2
Step 1Step 2
Step 1Step 2
Step 1Step 2
Step 1Step 2
Step 1Step 2
Step 1Step 2
Step 1Step 2
Step 1Step 2
Sample
Mo
isture A
nalyzer Sam
ple A
pp
lication
s
Enhanced Support for
ISO/GLP/GMP
50
(Printout Samples)
EP-100/EP-110 | Electronic Printers
Electronic Printers
EP-100/EP-110
EP-100 / EP-110 |
Electron
ic Printers
AP Series
|
0.01mg
~ 0.1m
g |
Specific G
ravity An
alyzer
Normal Mode
Compatible Balance ModelsAP, AU, AT, U, TX, TXB, BX-K, BL, and ELB series,and MOC63u moisture analyzers.Note: The automatic setting function cannot be used with models that do not include the PRINT key,such as ELB series balances and MOC63u moisture analyzers.
Specifications
Statistical Calculation Mode
Manufacturer InformationDevice Name
Serial No.Sample Name (ID)
DateMeasurement Start Time
Lot No.
Measurement Values
Measurement End Time
Signature Field
Display
Protected date setting
Printing
Interface
Power supply
Battery
Installation environment
Model
Paper for printing: Regular paper (does not fade with age)
Method: 8-pin reciprocating impact dot matrix
Speed: Approx. 1.7 lines/sec. Printer head life: 1 million lines
Character size: Approx. W1.7 × H2.6 mm
USB B-Type female, RS232 (D-sub 9-pin male)
AC adapter: Input 100 to 240 V AC, 50/60 Hz; Output 12 V DC/1500 mA
Power consumption: 8 W (while printing) Standby power: 0.5 W (when not printing)
Temperature: 5 to 45 °C; Humidity: 10 to 80 % No condensation
EP-100OLED 128 × 64 Dot Matrix DisplayEasy-to-understand fluorescent dot matrix display
Password protectable (six-character)
-
-
-
EP-110
1500 to 2500 mAh capacity rechargeable nickel metal--
hydride (NiMH) batteries can be used (four AA cells).
Note: Dry cell batteries cannot be used.
Eliminating the need for an AC adapter connection, the printer can be used as a portable device. It also means the printer can be used in locations without a power supply outlet, such as within a fume hood. Note: Dry cell batteries cannot be used (compatible with nickel metal hydride batteries).
Powered by Rechargeable Batteries
Shared Functionality
EP-100 Function EP-110 Function
The OLED display makes it easier to determine the measurement mode-based status. The OLED display also ensures visibility even in dark locations.
Status Display with Enhanced Visibility for OLED Display
· Built-In Clock· Affordably Priced
· Enhanced Visibility for OLED Display· Includes Functionality for Preventing Date Alterations
Supports GLP/GMP Using Password Protection-Based Date/Time Alteration Prevention●Built-In Clock Date/time can be printed even for balances without a clock function.
●Customized Printing In addition to weight measurement values, print items can also
be added to the end.
●Easy Communication Settings Includes functionality (automatic setting function)
that automatically sets communication settings based on the given balance.
Note: This function is disabled for ELB series models and MOC63u moisture analyzers.
●Titles for measurement values can be freely customized for printing.
EP-110EP-100
Output Items
Title (Header)
Number of samples
Total value
Maximum value
Minimum value
Range
Mean value
Standard deviation
Coefficient of variation
Data suffix (footer)
N
T
MAX
MIN
RNG
MEAN
SD
CV
SymbolManufacturer information, device name, serial number
(S/N), date, measurement start time, and lot number
= MAX – MIN
= T / N
∑(Xi-MEAN)2/(N-1)(SD / MEAN x 100)%
Measurement end time and signature field
RemarksItem
Maintenance Parts
Recording Paper
Labeling Paper Rolls
Ink Ribbon
AC Adapter
Connection Cable
Description
51
When combined with an optional specific gravity measurement kit, balances can be used to measure specific gravity.Operations are simplified by a text-based navigation function. By using sinkers, the specific gravity of liquid can be measured as well. This allows easily measuring of the specific gravity of metals, rubbers, plastics, and other materials.
Attach Special Optional Kit for Use as
Specific Gravity Analyzer
Specific Gravity AnalyzerSpecial Optional Kit for Use as
Gravity Analyzer
AP Series
Capacity
Minimum display
Pan size (mm)
Dimensions
Weight
Required power supply
Model
Approx. ø91Approx. W212 × D411 × H345 mm (including power supply unit) Approx. 212(W)×367(D)×345(H)mm
AC100V 270mA 50/60Hz
W Series X Series Y Series
135g
AP135W120g / 52g
AP125WD220g /102g
AP225WD120g
AP124W220g
0.1mg0.1mg / 0.01mg0.01mg
AP224W320g
AP324W120g
AP124X220g
AP224X320g
AP324X120g
AP124Y220g
AP224Y320g
AP324Y
Approx. 7.9kg Approx. 7.0kg Approx. 6.5kg
APseries
AP Series | 0.01mg ~ 0.1mg | Specific Gravity Analyzer
s, and other materials.
SMK-601 specific gravity measurement kit
First measure the in-air weight. Then place it in the container filledwith water, as instructed on the screen.
The specific gravity value is displayedusing simple steps.
Specific Gravity Measurement Kit
Note: The optional liquid density sinker is required for liquid density measurements.
Model SMK-601
Optional AccessoriesDescription
Liquid Density Sinker
Petri Dish, Square
5
6
Specific G
ravity An
alyzerPrin
ter
Simple!
52
Specific Gravity Analyzer
AUseries
AU Series | 0.01 mg to 0.1 mg | Specific Gravity Analyzer
Measures a Variety of Gravity Values with the Immersion Method
Measures a Variety of Gravity Values
with the Immersion Method
AU
Series |
0.01 mg
to 0.1 m
g |
Specific G
ravity An
alyzerU
W/U
X Series
|
0.001 g to
0.1 g |
Specific G
ravity An
alyzer
For standard sample
Two kinds of weighing pans as standard.
For floating sample
AUW Series + SMK-401
AUSeries
0.1 mg/0.01 mg
Approx ø80
Approx. W220 × D430 × H340 mm
Approx 7kg
AUW-D Series AUW Series
220 g/82 g
0.1 mg/0.05 mg
AUW220D120 g/42 g
0.1 mg/0.02 mg
AUW120D320 g
0.1 mg
AUW320
0.15 mg
220 g
0.1 mg
AUW220
0.1 mg
120 g
0.1 mg
AUW120
0.1 mg
320 g
0.1 mg
AUX320
0.15 mg
220 g
0.1 mg
AUX220
0.1 mg
120 g
0.1 mg
AUX120
0.1 mg
AUY Series
220 g
0.1 mg
0.1 mg
AUY220120 g
0.1 mg
0.1 mg
AUY120AUX Series
Attach the optional SMK401 Specific Gravity Measurement Kit to a balance in the AU series, and set the balance to specific gravity measurement mode. You can then use the balance as a specific gravity analyzer, capable of automatically calculating and displaying specific gravity values.Liquid density can also be measured by using an optional sinker.
Various models of balances are available, including a semi-micro (0.01mg) model. Choose the model best suited to the sample amount and required precision in your application.
Capacity
Minimum display
Repeatability
Pan size (mm)
Body Dimensions
Weight
Model name
Specific Gravity Measurement kit
SMK-401
Description
Optional Accessories
Liquid Density Sinker for SMK-401
Description
6
53
Measures a Variety of Specific Gravity Valueswith the Immersion MethodAttach the optional SMK-101/102/201 Specific Gravity Measurement Kit to a balance in the UW/UX series, and set the balance to specific gravity measurement mode. You can then use the balance as a specific gravity analyzer, capable of automatically calculating and displaying specific gravity values.Liquid density can also be measured by using an optional sinker.
Measures a Variety of Specific Gravity Values
with the Immersion Method
Specific Gravity Analyzer
UW/UXseries
UW/UX Series | 0.001 g to 0.1 g | Specific Gravity Analyzer
In addition to the above-mentioned, balances with the mark are equipped with a specific gravity calculation function, so they can be used for specific gravity measurement.
UW/UX Series + SMK-101
Various models of balances are available. Choose the model best suited to the sample amount and required precision in your application.
The large submersible pan makes it easy to measure bulky samples.
SMK-101 for large pan*1*2
形 名P/N
420 g 620 g 820 g 1020 g820 g
Approx. 108×1055 Approx. 108×1055 Approx. 108×1055 Approx. 108×1055Approx. 108×1055
420 g 620 g 820 g 1020 g420 g 820 g
Approx. 108×1055 Approx. 108×1055 Approx. 108×1055 Approx. 108×1055Approx. 108×1055 Approx. 108×1055
Optional AccessoriesDescription
Liquid Density Sinker for SMK-101/102
Capacity
Minimum display
Pan size (mm)
Model
2200 g 4200 g 6200 g 4200 g 8200 g0.01 g 0.01 g 0.01 g 0.1 g 0.1 g
UW2200H UW4200H UW6200H UW4200S UW8200S
Approx. 170×180 Approx. 170×180 Approx. 170×180 Approx. 170×180 Approx. 170×180
2200 g 4200 g 6200 g 4200 g 8200 g0.01 g 0.01 g 0.01 g 0.1 g 0.1 g
UX2200H UX4200H UX6200H UX4200S UX8200S
Approx. 170×180 Approx. 170×180 Approx. 170×180 Approx. 170×180 Approx. 170×180
Model UX220H UX420H UX620H UX820H UX1020H
0.001 g 0.001 g 0.001 g 0.001 g0.01 g
UX820S UW220H UW420H UW620H UW820H UW1020HUW420S
0.001 g 0.001 g 0.001 g 0.001 g0.01 g 0.01 g
UW820S
Specific Gravity Measurement KitModel SMK-102 for small pan*1*3
*1 The optional liquid density sinker is required for liquid density measurements.*2 For UW/UX series large-pan (170 × 180 mm) types. The actual capacity is 100 g smaller than the capacity of the balance.*3 For UW/UX series small-pan (108 × 105 mm) types. The actual capacity is 290 g smaller than the capacity of the balance. Cannot be attached to the UW/UX 220H.
UW/UXSeries Balances (large pan type)
UW/UXSeries Balances (small pan type)
Models with built-in calibration weights
Models with built-in calibration weights
Capacity
Minimum display
Pan size (mm)
420 g
Approx. 108×1055
UX420S
0.01 g
Specific G
ravity An
alyzer
54
Introduction to the Specific GravityMeasurement Procedures (AU Series)
Assemble the Specific Gravity Measurement Kit.1
Set the balance to specific gravitymeasurement mode. Then press the UNIT keyseveral times until the display unit changesto "▼d."
As shown in the photo at left,
"Air" will be displayed for a while,
and the in-air weight is then measured.
2
Press the O/T key to subtract the tare.3
Load the solid sample on thein-air pan.4
SoSimple!
Intro
du
ction
to th
e Specific G
ravity Measu
remen
t Proced
ures
55
Load the solid sample on thesubmerged pan.6
When the stability mark is lit, press theCAL key.
Sample Data Example
Sample
Aluminum
Brass
Copper
Specific gravity
2.68±0.1
8.45±0.4
8.8 ±0.4
7
*Results will differ depending on the shape and surface status of the sample, and the measurement conditions. The values in the table are at best reference values, and their precision is not guaranteed.
8
A "*" will be displayed in the numerical display, and the specific gravity of the solid sample will be displayed.To return to in-air measurement, press the
CAL key to display "Air" for in-air weight
measurement.
5
When the stability mark is lit, press theCAL key.
As shown in the photo at left, "wAtEr" will be displayed for a while, and the submerged weight is then measured.
6
Intro
du
ction
to th
e Specific G
ravity Measu
remen
t Proced
ures
56
Animal Balances
UW/UXseries
Attach an optional animal bucket to a UW/UX series balance, and set the unit to animal mode. The balance can now be used as a user-friendly animal balance.
Quick, Stable Measurements of Animal Weight
UWSeries
UXSeries
UW/UX Series | 0.01 g to 0.1 g | Animal Balances
The Clock-CAL function automatically performs sensitivity calibration at preset times, significantly reducing the labor for routine inspections. Naturally, one-touch sensitivity calibrations are also possible at any time.
UW series is equipped with built-in calibration weights
When the animal is unloaded, residual weight from excretions and other materials is automatically subtracted and the display is set to zero. The next animal can be loaded without pressing the TARE button, which increases efficiency.● Thanks to the specially developed animal measurement software, the weight of
moving animals is measured quickly and stably.
Animal Measurement Mode
Deep round bucket Rectangular bucketBucket for small animals
Three movement levels can be selected corresponding to the animal movement.Animals can be measured whether they are docile or extremely active.
When the animal is loaded and the stability mark is displayed, the weight is output automatically.Needless operation is eliminated to increase efficiency.
When the animal is unloaded, residual weight from excretions and other materials is automaticallysubtracted and the display is set to zero.
The next animal can be loaded without pressing the TARE button, which increases efficiency.
UW
/UX
Series |
0.01 g to
0.1 g |
An
imal B
alances
BW
-K/B
X-K
Series |
0.1 g to
1 g |
An
imal B
alances
UW/UXSeries (balance)
Capacity
Minimum display
Model
2200 g0.01 g
UW2200H4200 g0.01 g
UW4200H6200 g0.01 g
UW6200H4200 g0.1 g
UW4200S8200 g0.1 g
UW8200S2200 g0.01 g
UX2200H4200 g0.01 g
UX4200H6200 g0.01 g
UX6200H4200 g0.1 g
UX4200S8200 g0.1 g
UX8200SModels with built-in calibration weightsStandard models
Small Animal Bucket Shape: round / Size: bottom 110 dia. × top 200 dia. × height 130 (mm)
Deep Round Bucket Shape: round / Size: bottom 155 dia. × top 195 dia. × height 200 (mm)
Rectangular Bucket*1 Shape: rectangular / Size: bottom 250 × 210; top 290 × 250; height 150 (mm)
*1 The rectangular bucket can only be attached to the UX8200S and UW8200S.
57
Attach an optional animal bucket to a BW-K/BX-K series balance, and set the unit to animal mode. The balance can now be used as a user-friendly animal balance.
BW-KSeries
BX-KSeries
Animal Balances
BW-K/BX-Kseries
Quick, Stable Measurements of Animal Weight
BW-K/BX-K Series | 0.1 g to 1 g | Animal Balances
● Models with a range of capacities are available. Ideal for medium weight measurements of rabbits and small dogs.
● Thanks to the specially developed animal measurement software, the weight of moving animals is measured quickly and stably.
● When the animal is unloaded, residual weight from excretions and other materials is automatically subtracted and the display is set to zero. The next animal can be loaded without pressing the TARE button, which increases efficiency.
Animal Measurement Mode
Small bucket setMedium bucket set
BW-K/BX-KSeries (balance)
Capacity*1 *2
Minimum display
ModelModels with built-in calibration weights Standard models
*1 When an animal bucket is attached, the capacity will be reduced about 2 kg from the value indicated.*2 When an animal bucket is attached, the capacity will be reduced about 6 kg from the value indicated. *3 The bucket cannot be attached to the BW12KH or BX12KH.
BX12KH BX22KH BX32KH BX32KS BX52KSBW12KH BW22KH BW32KH BW32KS BW52KS12 kg 22 kg 32 kg 32 kg 52 kg12 kg 22 kg 32 kg 32 kg 52 kg
0.1 g 1 g0.1 g0.1 g 1 g0.1 g 0.1 g 0.1 g 1 g 1 g
Medium Bucket (mainly suited to small dogs)*3
Bucket
Shared Options for the UW/UX & BW-K/BX-K
Description
EP-100 Printer
EP-110 Printer
RS-232C cable (1.5 m)
USB-serial conversion kit
Shape: rectangular / Size: bottom 305 × 215; top 335 × 245; height 215 (mm)Small Bucket (mainly suited to rabbits)
Shape: rectangular / Size: bottom 335 × 245; top 445 × 295; height 345 (mm)
7
An
imal B
alances
58
• Eliminate manual entry and all the weighing data are saved automatically in a
safe database without transcription mistakes.
• Reports appropriate for weighing methods, such as the mass variation test,
drying weight loss test and particle size test, can be created automatically
after the measurement. In addition, customized reports featuring such
information as system conformance, content uniformity and elution tests
together with the analysis results obtained by HPLC, etc. can be created.
Improves Operational Efficiency and Data Reliability
Main Window of LabSolutions Balance
Integrated Management of Analytical Data on Network System Using LabSolutions
Integrate Analysis Data Acquired from Balances toAnalytical Network Data System Compliant with ER/ES Regulations
LabSolutions BalanceLabSo
lutio
ns B
alance
LabSolutions Balance
LabSolutions
Data search,analysis andapproval
Office
Other vendor’sinstrument
Thermal analyzer AA UV FTIR Balance
Server LC GC LCMS GCMS TOC
DB
To Establish an Internal AnalysisData Management System
59
• Weighing results can be automatically saved in the database together with other information, including sample ID, operator
name, operation date and series number of instrument used. This enables quick data searching based on sample information.
• It allows setting up user authority to ensure only the authorized user can create a template for weighing.
• It prevents improper manipulation, unintended overwriting and deletion of data. In addition, measurement results, all the
operation histories and reasons will be saved in the database as log files.
Compliant with the Latest Data Integrity Guidance (U.S. FDA 21 CFR Part 11)
Integrated Report Creation Function Combines Analysis Results from HPLCand Weighing Results from Balance
LabSolutions Data Manager
SpecificationsWindows 7 Professional (32bit/64bit), Windows 10 Pro
Shimadzu AP, AU, AT and UW/UX series
Controls up to 2 balance units, generation of PDF files, interface supporting linkage to LIMS system (option)
OS
Compatible Instruments
Other Functions
Batch Analysis Window
Select Report Template
Automatically print reports and
create PDF files.
Report template formats
can be freely customized.
After Analysis
Note: Multi-data report creation (optional) is necessary to use this function.
Creation of Report TemplateIt enables creating the report by reading sample data and confirming the sample report at the same time.
8
LabSo
lutio
ns B
alance
Accessories for Shimadzu Balances
Balances Optional accessories
Electronic Printer EP-100 / EP-110AUW-D/AUW / AUX /AUY Series
Foot Switch FSB-102TK (For taring)
Foot Switch FSB-102PK (For printing)
Specific Gravity Measurement Kit SMK-401
Application Keyboard AKB-301
RS-232C Cable, for IBM PC/AT Compatibles (25P-9P, Null modem, 1.5m)
In-use Protective Cover (5 pcs)
AP Series
Electronic Printer EP-100 / EP-110
IFB-102A-UNC
USB Conversion Kit
In-use Protective Cover (5 pcs)
I/O–RS Cable
ATX / ATYSeries
Optional accessories list
*1 USB serial adaptor and RS-232C cable for MOC are needed.
for UW/UX small-pan type
for UW/UX Series
Windbreak WBC-102
Large windbreak WBC-502
I/O–RS Cable
IFB-102A-UNC
Printer for MOC-120H
EP-110
EP-100
AUW-DAUWAUXAUY
TXB BL ELB BW-KBX-K MOC-120H
USB conversion kit with RS-232C cable
Foot switch
FSB-102TK
FSB-102PK
Specificgravitymeasurementkit
SMK-401
SMK-601
for TARE
for print
SMK-101, -102
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
✓
[no need] [no need] [no need] [no need] ✓✓ ✓ [no need] [no need]
[no need] [no need] [no need] [no need] ✓✓ ✓ [no need] [no need] [no need]
MOC63u
✓ ✓ ✓
✓
✓
✓ ✓ ✓ ✓ ✓ ✓ ✓✓ *1
✓ ✓
✓
✓
✓
✓
✓
✓
✓
✓
UWUX
ATXATY
✓
Application keyboardAKB-301
SMK-201for ELB large-panmodel
BL Series
ELB Series
Electronic Printer EP-100 / EP-110
In-use Protective Cover (5 pcs)
Simple Windbreak
Lid for Simple Windbreak
Electronic Printer EP-100 / EP-110
RS-232C Interface IFB-102A-UNC
In-use Protective Cover (5 pcs)
Specific Gravity Measurement Kit SMK-201 (Cannot be used with small-pan models)
IFB-102A-UNC
TX / TW / TXB / TXC / TWCSeries
Electronic Printer EP-100 / EP-110
In-use Protective Cover (5 pcs)
RS-232C Cable
BW-K / BX-KSeries
Electronic Printer EP-100 / EP-110
RS-232C Interface IFB-102A (for multiple connections)
Foot Switch FSB-102PK (For printing)
Application Keyboard AKB-301
MOC63u EP-100 Printer
EP-110 Printer
In-use Protection Cover for Display (5 pcs)
Aluminum Sheet
Fiberglass Sheet
Balances Optional accessories
EP-100 / EP-110 PrinterUW / UX Series
RS-232C Interface IFB-102A (for multiple connections)
Glass Windbreak (for models with capacity of 220 to 820 g only)
Large Size Windbreak (for all models)
Small Size Windbreak (for models with capacity of 300 to 620 g only) (Std Acc. for models with readability of 1 mg)
Specific Gravity Measurement Kit SMK-101(for models with capacity of 2200 g and up only)
Specific Gravity Measurement Kit SMK-102(for models with capacity of 420 to 820 g only)
Foot Switch FSB-102PK (For printing)
In-use Protective Cover (5 pcs)
Foot Switch FSB-102TK (For taring)
RS-232C Cable, for IBM PC/AT Compatibles (25P-9P, Null modem, 1.5 m)
RS-232C Cable, for multiple connections (25P-25P, Null modem, 1.5 m)
Application Keyboard AKB-301
Remote Display Unit RDB-201 with operation keys
Remote Display Unit RDB-202
Angle Adjuster and Wall Hook for Remote Display
Stand for Remote Display (1-m high)
Temperature Calibration Kit
Sample Pan (SUS)
RS-232C Cable
USB Connection Cable
Halogen Heater For Replacement
✓
[no need]
[no need]
✓
TXAP
Static Electricity Remover STABLO-AP Ionizer
Electronic Printer EP-100
Electronic Printer EP-110(Multifunction Printer with Liquid Crystal Display)
Label Roll Paper for EP-100/110 (10 Rolls)
Specific Measurement Kit SMK-601
Display Protective Cover (Set of 5)
USB Cable
RS-232 Cable
AC Adapter (Standard Accessory)
Internal Windbreak Plate
RSIO Interface Cable
6160
Optional AccessoriesOp
tion
al Accesso
ries
9
Op
tion
al Accesso
ries
Balances Optional accessories
Electronic Printer EP-100 / EP-110AUW-D/AUW / AUX /AUY Series
Foot Switch FSB-102TK (For taring)
Foot Switch FSB-102PK (For printing)
Specific Gravity Measurement Kit SMK-401
Application Keyboard AKB-301
RS-232C Cable, for IBM PC/AT Compatibles (25P-9P, Null modem, 1.5m)
In-use Protective Cover (5 pcs)
AP Series
Electronic Printer EP-100 / EP-110
IFB-102A-UNC
USB Conversion Kit
In-use Protective Cover (5 pcs)
I/O–RS Cable
ATX / ATYSeries
Optional accessories list
BL Series
ELB Series
Electronic Printer EP-100 / EP-110
In-use Protective Cover (5 pcs)
Simple Windbreak
Lid for Simple Windbreak
Electronic Printer EP-100 / EP-110
RS-232C Interface IFB-102A-UNC
In-use Protective Cover (5 pcs)
Specific Gravity Measurement Kit SMK-201 (Cannot be used with small-pan models)
IFB-102A-UNC
TX / TW / TXB / TXC / TWCSeries
Electronic Printer EP-100 / EP-110
In-use Protective Cover (5 pcs)
RS-232C Cable
BW-K / BX-KSeries
Electronic Printer EP-100 / EP-110
RS-232C Interface IFB-102A (for multiple connections)
Foot Switch FSB-102PK (For printing)
Application Keyboard AKB-301
MOC63u EP-100 Printer
EP-110 Printer
In-use Protection Cover for Display (5 pcs)
Aluminum Sheet
Fiberglass Sheet
Balances Optional accessories
EP-100 / EP-110 PrinterUW / UX SeriesRS-232C Interface IFB-102A (for multiple connections)
Glass Windbreak (for models with capacity of 220 to 820 g only)
Large Size Windbreak (for all models)
Small Size Windbreak (for models with capacity of 300 to 620 g only) (Std Acc. for models with readability of 1 mg)
Specific Gravity Measurement Kit SMK-101(for models with capacity of 2200 g and up only)
Specific Gravity Measurement Kit SMK-102(for models with capacity of 420 to 820 g only)
Foot Switch FSB-102PK (For printing)
In-use Protective Cover (5 pcs)
Foot Switch FSB-102TK (For taring)
RS-232C Cable, for IBM PC/AT Compatibles (25P-9P, Null modem, 1.5 m)
RS-232C Cable, for multiple connections (25P-25P, Null modem, 1.5 m)
Application Keyboard AKB-301
Remote Display Unit RDB-201 with operation keys
Remote Display Unit RDB-202
Angle Adjuster and Wall Hook for Remote Display
Stand for Remote Display (1-m high)
Temperature Calibration Kit
Sample Pan (SUS)
RS-232C Cable
USB Connection Cable
Halogen Heater For Replacement
Static Electricity Remover STABLO-AP Ionizer
Electronic Printer EP-100
Electronic Printer EP-110(Multifunction Printer with Liquid Crystal Display)
Label Roll Paper for EP-100/110 (10 Rolls)
Specific Measurement Kit SMK-601
Display Protective Cover (Set of 5)
USB Cable
RS-232 Cable
AC Adapter (Standard Accessory)
Internal Windbreak Plate
RSIO Interface Cable
61
9
Op
tion
al Accesso
ries
Physical Dimensions
AP124W, AP224W, AP324W, AP124X, AP224X, AP324X Weight: Approx. 7.0 kgAP124Y, AP224Y, AP324Y Weight: Approx. 6.5 kg
AP135W, AP125WD, AP225WD Weight: Approx. 7.9 kg
166213
344.
5
140.5(Aperture Dimension)
87.5259
ø91
9822
0.5(
Ap
ertu
re D
imen
sio
n)
135(
Ap
ertu
re D
imen
sio
n)
90.5
432.8367
243
421
170
180
6.5
156
HOOK FOR UNDER PAN
HOOK FOR UNDER PAN
166213
344.
5
136
73.5
(180)(407)
87.525990.5
44
170
ø91
135(
Ap
ertu
re D
imen
sio
n)
243
180
421
140.5(Aperture Dimension)
216.
5(A
per
ture
Dim
ensi
on
)
432.8367
98
156
6.5
62
Physical DimensionsPhysical D
imen
sion
s
AP Series
AUW-D/AUW/AUX/AUY Series ATX/ATY Series
6.5 24 309
163
99
126
423235
440
253
134
172
223
356
338
217
168
185
ø80
BELOW-WEIGH HOOK
1.5
1.5
ø20
5
2
3.6
2
16.5
3.5
SensorBELOW-WEIGH HOOK
Case bottom
185
163213
222
102
338
8
26 307
356
432
138
244
ø91
170
426
240
162
136
63
Measurements in mm. 1 mm=.03937"
AW/AX/AY Series
BW-K Series BX-K Series
BL Series
Large-pan model Small-pan model
Figure shows combination with windbreak (standard only for BL220H and BL320H)
BW-K/BX-K Series
TW/TX/TXB/TWC/TXC Series
TX/TW series TXB series
212
260.3
198.
5
260.3
198.
5
77.1
77.1
160ø
110ø
21326.9
291
191.370.7
79.5
233.
2
181.8145
145
167.
8
200
147.
1
163
129.2
392.8
200
374.3192.370.7
291
161.5
127
10
Physical D
imen
sion
s
64
Physical DimensionsPhysical D
imen
sion
s
Physical Dimensions
UW/UX large-pan model with large windbreak (optional accessory)
UW/UX small-pan model with glass windbreak (optional accessory)
UW/UX Series
BELOW-WEIGH HOOK
ø20
30.7
4.6
4
3
4.5 10
9
317
118
5758
191
78.8
5
180.
5
80
8417
119
202
166
379
(364)
85103
9
BELOW-WEIGH HOOKBELOW-WEIGH HOOK
317191
78.8
5
180
Small-pan model *1
Large-pan model
*1 Figure shows combination with simple windbreak (standard only for models with minimum display of 0.001 g).
The delivered windbreak may differ slightly in size and shape.
65
Measurements in mm. 1 mm=.03937"
ELB Series
Large-pan model Small-pan model
220
415
190
400
MOC63u
336
174.4 161.6 3.7
84
144
144
129.864.5
24.6
(Th
e h
eig
ht
bet
wee
n p
an
a
nd
pro
tect
ion
gla
ss.)
157
201.6
160
202
25070.4
ø95
291.
4
13.6
MOC-120H
EP-100/EP-110
ø110
170
188 188
130
Front leg:144 / Rear leg: 158 Front leg:144 / Rear leg: 158
216216145145 56
58 58
56
188.
2
114.6 86.6
STABLO-AP
POWER RUN ALARM
POWER RUN ALARM
START/STOP
124
49
87
164
90147.7
147
1304
35
10±2 110±3
70±
3
10
Physical D
imen
sion
s
© Shimadzu Corporation, 2017
www.shimadzu.com/an/
For Research Use Only. Not for use in diagnostic procedures. This publication may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country.Company names, products/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation, its subsidiaries or its affiliates, whether or not they are used with trademark symbol “TM” or “®”.Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether or not they are used with trademark symbol “TM” or “®”.Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own.
The contents of this publication are provided to you “as is” without warranty of any kind, and are subject to change without notice. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication.
Printed in Japan 3655-10707-20ANS
Shimadzu Electronic Balances Demonstration Movies
https://www.youtube.com/playlist?list=PLCPY11zjvhZPmTi_xW1oGJeSuI-YR6qaV
ATX ATY Series
UniBloc
TX TXB TXC Series Top-loading Balances
Analytical Balance AP Series
Analytical Balance AP Series
Effects Of Static Electricity
Effects of static electricity
Improved Response Time of AP series
Sample Preparation by Analytical Balance, AP Series
Effects of Static Electricity
Recipe Preparation by Analytical Balance, AP Series SETUP
Recipe Preparation by Analytical Balance, AP Series OPERATION