4
GP-5001 NC-5001 NC-5001W Combustible gases Combustible gases Inert gases Combustible gases Toxic gases NP-5001 SP-5001 GH-5001 EC-5002 (i) Toxic gases OX-5001 RM-5002 (i) RM-5003 Oxygen 4-20mA input for Combustible gases Toxic gases Oxygen etc. OX-5002 (i) MODEL LPG, LNG utilities Refineries Chemical plants Semi-conductor manufacturing plants Engineering, public works Power station Iron and steel works Automotive Plating Processes APPLICATION Compatible with RM-570A /580 series Bar meter and digital multi-indication High level of visibility Low power consumption Support RS-485 communication function RoHS Compliant Global standard FEATURES RM - 5000 series MU L TI-C HA NNEL GAS MONITORING SY S TEM MULTI-CHANNEL GAS MONITORING SYSTEM C1E - 0343

C1E-0343 SPECIFICATIONS MULTI-CHANNEL€¦ · Tx Rx WH WL mV mA ppb ppm x10 x10 vol% %LEL RS-485 Master unit PC, PLC, DCS, etc.. RM-570A/RM-580 series Single-case RM-570A/RM-580 series

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

  • GP-5001NC-5001NC-5001W

    Combustible gases

    Combustible gasesInert gases

    Combustible gasesToxic gases

    NP-5001

    SP-5001

    GH-5001

    EC-5002 (i) Toxic gases

    OX-5001

    RM-5002 (i)

    RM-5003

    Oxygen

    4-20mA input for Combustible gases Toxic gases Oxygen etc.

    OX-5002 (i)

    MODEL

    Indicator/Alarm unit

    Buzzer unit

    GP-5001NC-5001

    NC-5001WNP-5001 SP-5001 GH-5001 EC-5002EC-5002i

    Output of electric power transmission (non-isolated) 4-20mADC, max loop load 300

    Flashing or lighting lamp: Red(ALM1), Red (ALM2), Self-Latching or Auto reset, Lock-in

    Orange lamp flashing (FAULT), Non-latching/Content indication

    Normally energized or de-energized, Normally-open or closed contact Rated 0.5A at 100VAC, 1.5A at 30VDC (resistive)

    -10 ~ +40℃(14 ˚F to 104 ˚F ), 10 ~ 90%RH (non-condensing)

    24VDC ±10%

    MAX 7W MAX 3W

    Card type with front display used enclosed in a case (a single-unit or multi-unit case)Specification subject to change without notice.

    MAX 2W MAX 3W MAX 2W

    TAN-5000 TAN-5000L

    Self-latching Lock-in

    Buzzer sound (Released after reset)

    Auto reset

    Normally energized or de-energized, Normally-open or closed contact

    -10 ~ +40℃ (14 ˚F to 104 ˚F ), 10 ~ 90%RH (non-condensing)

    MAX 2W

    Card type with front display used enclosed in a case (a single-unit or multi-unit case)

    OX-5001 OX-5002OX-5002iRM-5002RM-5002i RM-5003

    Max 600mMax 2.0km Max 2.0km Depending on thedetector

    CVVS-4CCVV-4C CVV-4C CVVS-3C CVVS-2C CVVS-3C

    Direct sensor signal 4-20mAoutputDirectsensorsignal

    4-20mA output

    Catalyticcombustion/New ceramic

    type

    Thermalconductivity

    type

    Hot-wiresemiconductor

    typeSemiconductor

    typeElectrochemical

    type Galvanic cell type2-wire type 3-wire type

    4-20mA outputs

    Combustible CombustibleInert gases Combustible /Toxic Toxic

    Character LCD (Digital and bar meter )

    OxygenCombustible

    ToxicOxygen

    RM-5000series

    Detection gas

    Indication

    Type of acceptable detector head

    Acceptableinput signal

    Applicablecable

    Max distance

    Output signal

    Alarm indication

    Fault alarm

    Alarm relays

    Operationcondition

    Power supply

    Powerconsumption

    Dimensions &Weight

    Structure

    Model

    Common gas alarmfunction

    Common gas alarm

    Common fault alarm

    Alarm relays

    Operation condition

    Power supply

    Dimensions & Weight

    Structure

    Specification subject to change without notice.

    SPECIFICATIONS

    Ω

    LPG, LNG utilitiesRefineriesChemical plantsSemi-conductor manufacturing plantsEngineering, public worksPower stationIron and steel worksAutomotive Plating Processes

    APPLICATIONCompatible with RM-570A /580 seriesBar meter and digital multi-indicationHigh level of visibilityLow power consumptionSupport RS-485 communication functionRoHS CompliantGlobal standard

    FEATURES

    RM-5000series

    MULTI-CHANNELGAS MONITORING SYSTEMMULTI-CHANNELGAS MONITORING SYSTEM

    Approx. 29.6 (W) × 120 (H) × 92 (D) mm ( 1.16 (W) × 4.72 (H) × 3.62 (D) inch), 100g (3.52 oz )

    Approx. 29.6 (W) × 120 (H) × 92 (D) mm ( 1.16 (W) × 4.72 (H) × 3.62 (D) inch), 80g (2.82 oz )

    C1E-0343

    C1E-0343-180630 S

    Distributed by:Distributed by:

    2-7-6 Azusawa, Itabashi-ku, Tokyo 174 -8744, Japan: +81-3-3966-1113: +81-3-3558-9110: [email protected]: http://www.rikenkeiki.co.jp/english

    PhoneTelefaxE-mail

    Web sitePrinted in Japan

  • Tx

    Rx

    WHWL

    mVmAppb

    ppmx10

    x10

    vol%%LEL

    RS-485

    Master unit PC, PLC, DCS, etc..

    RM-570A/RM-580 seriesSingle-case

    RM-570A/RM-580 seriesMulti-case

    It can be used with existing Multi/Single case of RM-570A/RM-580 series by use of con-nection case 5000-CC without new installation works. Also it is compatible with replace-ment to use existing facilities for expansion.

    Indicator/Alarm unitRM-5000 series

    Connection case5000-CC

    Buzzer

    Power lamp

    Fault lamp

    Full scale

    Bar meter indication

    Communication status

    Inhibit

    Maintenance status Double range

    Detection unit

    Current / Voltage

    Gas name/Message

    Digital indication

    BUZZER UNIT

    Reset switch

    COMPONENT DESIGNATIONS 3-COLOR LCD INDICATION

    Extend monitoring system

    INDICATION

    INDICATOR/ALARM UNIT

    Maximum 32 points can be connected to use RS-485

    Alarm reset switch

    Turn on during power on

    Turn on in any trouble

    Open the cover • Power switch

    Display the full scale

    Divide the full scale in fifty (50)

    Display gas concentration and message (7 segments)

    Display gas name and message (14 segments)

    Depending on gas specifica-tion

    Display on during mainte-nance mode

    Display in case of Double range specification

    Display in pointskip setting, and no alarm in this setting

    Display during maintenance mode

    Display during communicate with master unit to use RS-485

    Power lampTurn on during power on

    1st alarm lampFlash for 1st alarm level

    2nd alarm lampFlash for 2nd alarm level

    Fault alarm lampFlash for any trouble

    DisplayDisplay the gas name/concentration

    Open the cover • Power switch • PC connection port • Mode switch • ALM2/▲switch • ALM1/▼switch • TEST/SET switch

    Compatible with RM-570A/RM-580 series

    Display indicates gas concentration by two ways, Bar meter and Digital meter. Also LCD will change the color depending on the concentration, so you can confirm detection condition from a distance.

  • Tx

    Rx

    WHWL

    mVmAppb

    ppmx10

    x10

    vol%%LEL

    RS-485

    Master unit PC, PLC, DCS, etc..

    RM-570A/RM-580 seriesSingle-case

    RM-570A/RM-580 seriesMulti-case

    It can be used with existing Multi/Single case of RM-570A/RM-580 series by use of con-nection case 5000-CC without new installation works. Also it is compatible with replace-ment to use existing facilities for expansion.

    Indicator/Alarm unitRM-5000 series

    Connection case5000-CC

    Buzzer

    Power lamp

    Fault lamp

    Full scale

    Bar meter indication

    Communication status

    Inhibit

    Maintenance status Double range

    Detection unit

    Current / Voltage

    Gas name/Message

    Digital indication

    BUZZER UNIT

    Reset switch

    COMPONENT DESIGNATIONS 3-COLOR LCD INDICATION

    Extend monitoring system

    INDICATION

    INDICATOR/ALARM UNIT

    Maximum 32 points can be connected to use RS-485

    Alarm reset switch

    Turn on during power on

    Turn on in any trouble

    Open the cover • Power switch

    Display the full scale

    Divide the full scale in fifty (50)

    Display gas concentration and message (7 segments)

    Display gas name and message (14 segments)

    Depending on gas specifica-tion

    Display on during mainte-nance mode

    Display in case of Double range specification

    Display in pointskip setting, and no alarm in this setting

    Display during maintenance mode

    Display during communicate with master unit to use RS-485

    Power lampTurn on during power on

    1st alarm lampFlash for 1st alarm level

    2nd alarm lampFlash for 2nd alarm level

    Fault alarm lampFlash for any trouble

    DisplayDisplay the gas name/concentration

    Open the cover • Power switch • PC connection port • Mode switch • ALM2/▲switch • ALM1/▼switch • TEST/SET switch

    Compatible with RM-570A/RM-580 series

    Display indicates gas concentration by two ways, Bar meter and Digital meter. Also LCD will change the color depending on the concentration, so you can confirm detection condition from a distance.

  • GP-5001NC-5001NC-5001W

    Combustible gases

    Combustible gasesInert gases

    Combustible gasesToxic gases

    NP-5001

    SP-5001

    GH-5001

    EC-5002 (i) Toxic gases

    OX-5001

    RM-5002 (i)

    RM-5003

    Oxygen

    4-20mA input for Combustible gases Toxic gases Oxygen etc.

    OX-5002 (i)

    MODEL

    Indicator/Alarm unit

    Buzzer unit

    GP-5001NC-5001

    NC-5001WNP-5001 SP-5001 GH-5001 EC-5002EC-5002i

    Output of electric power transmission (non-isolated) 4-20mADC, max loop load 300

    Flashing or lighting lamp: Red(ALM1), Red (ALM2), Self-Latching or Auto reset, Lock-in

    Orange lamp flashing (FAULT), Non-latching/Content indication

    Normally energized or de-energized, Normally-open or closed contact Rated 0.5A at 100VAC, 1.5A at 30VDC (resistive)

    -10 ~ +40℃(14 ˚F to 104 ˚F ), 10 ~ 90%RH (non-condensing)

    24VDC ±10%

    MAX 7W MAX 3W

    Card type with front display used enclosed in a case (a single-unit or multi-unit case)Specification subject to change without notice.

    MAX 2W MAX 3W MAX 2W

    TAN-5000 TAN-5000L

    Self-latching Lock-in

    Buzzer sound (Released after reset)

    Auto reset

    Normally energized or de-energized, Normally-open or closed contact

    -10 ~ +40℃ (14 ˚F to 104 ˚F ), 10 ~ 90%RH (non-condensing)

    MAX 2W

    Card type with front display used enclosed in a case (a single-unit or multi-unit case)

    OX-5001 OX-5002OX-5002iRM-5002RM-5002i RM-5003

    Max 600mMax 2.0km Max 2.0km Depending on thedetector

    CVVS-4CCVV-4C CVV-4C CVVS-3C CVVS-2C CVVS-3C

    Direct sensor signal 4-20mAoutputDirectsensorsignal

    4-20mA output

    Catalyticcombustion/New ceramic

    type

    Thermalconductivity

    type

    Hot-wiresemiconductor

    typeSemiconductor

    typeElectrochemical

    type Galvanic cell type2-wire type 3-wire type

    4-20mA outputs

    Combustible CombustibleInert gases Combustible /Toxic Toxic

    Character LCD (Digital and bar meter )

    OxygenCombustible

    ToxicOxygen

    RM-5000series

    Detection gas

    Indication

    Type of acceptable detector head

    Acceptableinput signal

    Applicablecable

    Max distance

    Output signal

    Alarm indication

    Fault alarm

    Alarm relays

    Operationcondition

    Power supply

    Powerconsumption

    Dimensions &Weight

    Structure

    Model

    Common gas alarmfunction

    Common gas alarm

    Common fault alarm

    Alarm relays

    Operation condition

    Power supply

    Dimensions & Weight

    Structure

    Specification subject to change without notice.

    SPECIFICATIONS

    Ω

    LPG, LNG utilitiesRefineriesChemical plantsSemi-conductor manufacturing plantsEngineering, public worksPower stationIron and steel worksAutomotive Plating Processes

    APPLICATIONCompatible with RM-570A /580 seriesBar meter and digital multi-indicationHigh level of visibilityLow power consumptionSupport RS-485 communication functionRoHS CompliantGlobal standard

    FEATURES

    RM-5000series

    MULTI-CHANNELGAS MONITORING SYSTEMMULTI-CHANNELGAS MONITORING SYSTEM

    Approx. 29.6 (W) × 120 (H) × 92 (D) mm ( 1.16 (W) × 4.72 (H) × 3.62 (D) inch), 100g (3.52 oz )

    Approx. 29.6 (W) × 120 (H) × 92 (D) mm ( 1.16 (W) × 4.72 (H) × 3.62 (D) inch), 80g (2.82 oz )

    C1E-0343

    C1E-0343-180630 S

    Distributed by:Distributed by:

    2-7-6 Azusawa, Itabashi-ku, Tokyo 174 -8744, Japan: +81-3-3966-1113: +81-3-3558-9110: [email protected]: http://www.rikenkeiki.co.jp/english

    PhoneTelefaxE-mail

    Web sitePrinted in Japan