g GE Healthcare

Centricity* PACS Customer Release Notes

PACS 4.0 Release

Do not duplicate.Copyright © 2001-2014 by General Electric Co.*Trademark of General Electric Co.

Page 2: C40_CRN_2085198-001sp10

Copyright Information

All Licensed Software is protected by the copyright laws of the United States and by applicable international treaties. No rights under copyrights are transferred to Customer, except as specifically provided in the License Grant section.

Trademark Information

GE, the GE Monogram, and Centricity are trademarks or registered trademarks of the General Electric Company. All other product names and logos are trademarks or registered trademarks of their respective owners.

Confidentiality and Proprietary Rights

This document is the confidential property of GE and/or its affiliated entities. It is furnished to, and may only be used by, customers and their employees under a written agreement with GE and may only be used in accordance with the terms of that agreement. The access and use of this document is restricted to customers and their employees. The user of this document agrees to protect the confidentiality of the information contained herein and GE’s proprietary rights as expressed herein and not permit access to this document by any person for any purpose other than as an aid in the use of the GE software. In no case may this document or any portion hereof be accessed, made available, examined, or copied for the purpose of developing, marketing, or supporting any system or computer program similar to the GE software. No part of this document may be copied without the prior written permission of GE. The information in this document is subject to change by GE without notice.

Inquiries regarding permission for use of material contained in this document should be addressed to:

GE Healthcare, ATTN: General Counsel, 540 W. Northwest Highway, Barrington, IL 60010

Publication Date and Document Numbers

November 20, 2014

DOC1594112

2085198-001

Service Pack

SP10

2085198-001 2

Page 3: C40_CRN_2085198-001sp10

General Definitions of Symbols

The following table defines symbols used throughout this document and the product software:

Symbol Definition

This symbol indicates the AUTHORIZED REPRESENTATIVE IN THE EUROPEAN COMMUNITY of the product.

This symbol indicates the MANUFACTURER of the product.

This symbol indicates the DATE OF MANUFACTURE of the product.

This symbol indicates that the operator should CONSULT INSTRUCTIONS FOR USE for further information.

This symbol indicates the manufacturers BATCH CODE, or lot number of the product.

The symbol for CAUTION highlights the fact that there are specific warnings or precautions associated with the device.

The WEEE symbol indicates that the waste of electrical and electronic equipment must not be disposed as unsorted municipal waste and must be collected separately.

2085198-001 3

Page 4: C40_CRN_2085198-001sp10

Contents

Chapter 1 About This Release 6

Section 1: Centricity PACS 4.0 SP10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Other Related Release Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Section 2: Contacting GE Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Applications Support and Service Support (Asia Regions) . . . . . . . . . . . . . . . . . . . . 6

Applications Support Using iCenter, eService, and Applications Answerline . . . . . . 7

Contact Information for GE Healthcare Offices . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Section 3: Software Media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

PACS KCAT List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

AW Server KCAT List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Section 4: Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Section 5: Documentation Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Text Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Screen Captures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Section 6: Configure Adobe Reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Section 7: Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Section 8: Acronyms and Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Chapter 2 System Requirements 13

Section 1: Centricity PACS Servers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Hardware and Software Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Hardware Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Browser Support for Centricity PACS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

C2C Server Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Java 1.7 Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

SPINE Authentication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Virtual Machine Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Section 2: RA1000 Workstation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Software Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Hardware Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Chapter 3 Release Content 27

Section 1: Features and Enhancements Effective with Centricity PACS 4.0 SP10 . . . 27

RA1000 Workstation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Centricity PACS Servers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

2085198-001 4

Page 5: C40_CRN_2085198-001sp10

Section 2: Issues Resolved in Centricity PACS 4.0 SP10 . . . . . . . . . . . . . . . . . . . . . . 31

Section 3: Upgrade Paths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

Chapter 4 Open Issues 43

Section 1: Report Palette Out of Synch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

Section 2: Browser Behavior When Using the Centricity Administration Tool . . . . . . . . 43

Safari for Windows Issue . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

Viewing the Calendar in the CA Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

Security Prompt When Navigating the CA Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

Chapter 5 System Documentation Additions and Corrections 45

Section 1: RA1000 Workstation and Exam Manager Operator Manual . . . . . . . . . . . . 45

Filtering Images Not Supported for Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

Extends Online Help Not Available in Norwegian . . . . . . . . . . . . . . . . . . . . . . . . . . 45

Section 2: Workstation Installation and Service Manual . . . . . . . . . . . . . . . . . . . . . . . . 46

QC Tool Button Is Not Configurable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

Synchronizing the Reporting System and RA1000 Worklist Selection (Browse Mode) 46

Platinum Extend Property Default in RIS-IC–PACS Integration . . . . . . . . . . . . . . . 47

DDPs and Filtering Images Not Supported for Display . . . . . . . . . . . . . . . . . . . . . . 47

Section 3: Servers Service Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

Setting ENM Configuration for HL Timeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

Section 4: System Administrator Online Help Manual . . . . . . . . . . . . . . . . . . . . . . . . . 49

Enabling a User to Search for Another User . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

2085198-001 5

Page 6: C40_CRN_2085198-001sp10

Chapter 1 About This Release

This chapter includes:

Section 1: Centricity PACS 4.0 SP10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Section 2: Contacting GE Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Section 3: Software Media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Section 4: Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Section 5: Documentation Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Section 6: Configure Adobe Reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Section 7: Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Section 8: Acronyms and Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Section 1: Centricity PACS 4.0 SP10

Centricity* PACS 4.0 SP10 is an upgrade release for both the RA1000 workstation and the PACS servers.

This release contains new features and resolutions for certain product defects. For complete information, see “Release Content” on page 27.

1-1: Other Related Release Notes

Resolved and open issues from prior releases apply to this release. For information on resolved issues, see the release notes for prior releases.

To access copies of the release notes, visit the Common Documentation Library (CDL).

Section 2: Contacting GE Support

2-1: Applications Support and Service Support (Asia Regions)

To request applications support or service support for the Asia regions, refer to the following phone numbers.

*Trademark of General Electric Co.

Table 1-1: Applications Support and Service Support (Asia Regions)

Country Support Phone Number

Australia 1800659465

China 8008108188

2085198-001 6

Page 7: C40_CRN_2085198-001sp10

Chapter 1 About This Release

2-2: Applications Support Using iCenter, eService, and Applications Answerline

To request applications support, English-speaking customers may open a support request in GE Healthcare iCenter™ or eService. Other customers should contact their GE Field Engineers or support personnel.

With iCenter or eService you can:

Initiate requests for service and applications support from the web

Get rapid, online access to the Remote Online Center (ROC) where expert service engineers review and respond to service requests quickly

View the status of open service requests

View service history and reports about your systems, including uptime, remote fix and service call trends, and other service delivery metrics

If you do not have access to iCenter or eService, contact your Director of Service or Service Engineer to open an account. English-speaking customers can also use the following resource:

GE PACS Applications Answerline 1-855-762-6650, and select the option for your product (available for US and Canadian customers)

2-3: Contact Information for GE Healthcare Offices

Addresses and phone numbers for GE Healthcare offices are listed below.

Hong Kong 21006288

India 1800114567

Japan 0120055919

Korea 15446119

Malaysia 1800883911

New Zealand 0800659465

Singapore 63880932

Taiwan 0800021770

Table 1-1: Applications Support and Service Support (Asia Regions) (Continued)

Country Support Phone Number

2085198-001 7

Page 8: C40_CRN_2085198-001sp10

Chapter 1 About This Release

Corporate Headquarters

GE Healthcare 540 W Northwest HighwayBarrington, IL 60010 USATel: +1 847 277-5000 or +1 800-437-1171 or +1 800-682-5327 Fax: +1 847 277-5240

European Headquarters

GE Medical Systems SCS283 rue de la Minière78530 BUC, France

Asia Headquarters

GE Healthcare1 BLD-3FNo. 1 Hua Tuo Road, Zhang Jiang Hi-Tech Park Shanghai 201203 ChinaTel: 8621-38777888Fax: 8621-38777499

Section 3: Software Media

Important The Centricity PACS 4.0 SP10 release of the DVD CPACS LINUX PLATFORM 5.8 media includes the patch for “Shellshock: Bash Code Injection Vulnerability via Specially Crafted Environment Variables (CVE-2014-6271, CVE-2014-7169).” Servers loaded using this platform media will not have the Shellshock vulnerability. Sites that do not reload servers should install the previously distributed BASH patch. Contact your GE support representative for more information.

Table 1-2 lists the Centricity PACS software media for this release.

Table 1-2: Software Media for Centricity PACS 4.0 SP10

Media Description Media Build Number

Media Part Number

Media Revision

CD CPACS 4.0 SP10 WS TOOLS 2027437-017 2064670-001 G

CD CPACS 4.0 SP10 ON-LINE HELP 2063983-009 2064671-001 G

CD CPACS 4.0 SP10 WS APP 2062264-068 2064672-001 G

DVD CPACS 4.0 SP10 LINUX SRVR APP 2062265-040 2064673-002 G

CD CPACS 4.0 SP10 CDPS 2062266-005 2064674-001 G

2085198-001 8

Page 9: C40_CRN_2085198-001sp10

Chapter 1 About This Release

3-1: PACS KCAT List

For KCAT information for this release, see the Product Configuration Master for Centricity PACS 4.0 (DOC1166416).

3-2: AW Server KCAT List

For KCAT information for this release, see the Product Configuration Master for Centricity PACS 4.0 (DOC1166416).

Section 4: Related Documentation

The table below lists the related documentation for this Centricity PACS release.

Note: Only the product manuals that were affected by the service pack (SP) scope of this Centricity PACS 4.0 release were updated. Therefore, the documentation set for this release includes a combination of SP numbers: product manuals that required updating for this release (SP10) and product manuals from prior releases that did not require updating for this release.

Visit the Common Documentation Library (CDL) for the current version of each manual.

DVD CPACS LINUX PLATFORM 5.8 2051376-007 2064675-002 G

DVD CPACS 4.0 SP10 LINUX REPLICATION 2051377-019 2064676-001 G

DVD CPACS 4.0 SP10 APP WITH 3.2 BASELINE 2051374-011 2065943-002 F

DVD PACS-AW 4.0 SP10 SERVER PLUG IN 2057958-005 2076535-001 E

Table 1-2: Software Media for Centricity PACS 4.0 SP10 (Continued)

Media Description Media Build Number

Media Part Number

Media Revision

Table 1-3: Centricity PACS Related Documentation

Manual Document Number

Centricity PACS 4.0 DICOM Print Server Service Manual 2086829-001

Centricity PACS 4.0 System Administrator Online Help Manual 2085195-001

Centricity PACS 4.0 Servers Installation and Upgrade Manual 2085194-001

Centricity PACS 4.0 Servers Service Manual 2085196-001

Centricity PACS 4.0 System Overview Manual 2086828-001

2085198-001 9

Page 10: C40_CRN_2085198-001sp10

Chapter 1 About This Release

Section 5: Documentation Conventions

5-1: Text Conventions

Table 1-4 lists text conventions used in this manual.

Centricity PACS 4.0 Workstation Installation and Service Manual 2086046-001

Centricity PACS 4.0 RA1000 Workstation and Exam Manager Operator Manual

Note: 2085191-001 for Great Britain; 2085192-101 for French; 2085190-xxx for all other languages, where xxx is the country code for localization.

2085192-001

Centricity PACS 4.0 RA1000 Workstation Quality Control Manual

Note: -001 for English version; -xxx for all other supported languages, where xxx is the country code for localization

2081376-001

Centricity PACS 4.0 Quality Control Maintenance Procedures 2086830-001

Centricity Extends Online Help Manual 2031481-001

Centricity Extends PowerScribe Service Manual 2032052-001

Centricity Extends TalkStation Service Manual 2013111-001

Centricity AW Suite 1.0 Service Manual 2024300-001

Centricity AW Suite 2.0 Installation, Upgrade, and Service Manual 2030968-001

Table 1-3: Centricity PACS Related Documentation (Continued)

Manual Document Number

Table 1-4: Text Convention Descriptions

Convention Description

Text represented as a screen display.

This typeface represents displays that appear on your terminal screen, for example:

lom>

Text represented as menu or sub-menu names.

This typeface represents all menu and sub-menu names within procedures, for example:

On the File menu, click New.

2085198-001 10

Page 11: C40_CRN_2085198-001sp10

Chapter 1 About This Release

5-2: Screen Captures

The example screens in this manual may not represent what you see on your monitor; use them only as guidelines.

Section 6: Configure Adobe Reader

Adobe Reader offers powerful view, navigation, and multi-document search tools that are not displayed by default. For example, the Previous View and Next View tools work like Backward and Forward in a web browser. And the advanced search tool enables you to search all PDF files in a directory. To configure these tools, see your Adobe Reader documentation.

Section 7: Safety

For safety information regarding Centricity PACS, refer to the Centricity PACS RA1000 Workstation and Exam Manager Operator Manual and the Centricity PACS Servers Service Manual for this release.

Section 8: Acronyms and Abbreviations

Table 1-5: Acronyms and Abbreviations

Term Definition

C2C Centricity to Centricity

CDPS Centricity DICOM Print Server

DAS DICOM Application Server

DDP Default Display Protocol

DICOM Digital Imaging and Communications in Medicine

IDR Integrated Desktop Reporting

IMS Information Management System

ITS Image Transfer Service

IV Image Volume

PACS Picture Archiving and Communication System

RIS Radiology Information System

2085198-001 11

Page 12: C40_CRN_2085198-001sp10

Chapter 1 About This Release

SSD Solid-State Drive

Table 1-5: Acronyms and Abbreviations (Continued)

Term Definition

2085198-001 12

Page 13: C40_CRN_2085198-001sp10

Chapter 2 System Requirements

This chapter includes:

Section 1: Centricity PACS Servers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Section 2: RA1000 Workstation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

For a PDF copy of the Centricity PACS 4.0 SP10 release notes, visit the Common Documentation Library (CDL).

Section 1: Centricity PACS Servers

1-1: System Requirements

PACS 4.0 SP10 supports the minimum hardware configurations listed in Table 2-1 for each server or client subsystem. No Solaris servers are supported. All servers must be capable of supporting a 64-bit operating system.

1-2: Hardware and Software Compatibility

Table 2-2 lists the hardware and software compatible with Centricity PACS servers and subsystems in this release.

Table 2-1: Minimum Hardware Requirements for Centricity PACS Servers

Function CPU Type # CPUs x# Cores/CPU

Disk Space Memory

IMS (XLDB, 100GB) x86–64 2 6 x 146GB (RAID5) 8GB

IMS (XXLDB, 300GB) x86–64 4 10 x 146GB (RAID5) 16GB

IMS (XXXLDB, 300GB–3TB) x86–64 4 2 x 146GB (Internal, RAID1) + 24 x 146GB (SAN, RAID1+0, RAID5)

16GB

DAS, ITS, C2C, Coordination Module, Replication Server

x86–64 2 2 x 36GB (RAID1) 2GB

DAS/IV x86–64 2 2 x 36GB (RAID1) + 10 x 146GB (RAID5)

4GB

CDPS x86 2 2 x 74GB (RAID1) 2GB

2085198-001 13

Page 14: C40_CRN_2085198-001sp10

Chapter 2 System Requirements

1-3: Hardware Compatibility

Caution: Hardware supplied by customers must meet all applicable standards listed under the “Certifications” section in the Centricity PACS RA1000 Workstation and Exam Manager Operator Manual for this release of Centricity PACS.

Important Before installing or upgrading, verify that your site hardware meets Centricity PACS compatibility requirements. If your site's hardware is not listed in this section, escalate to your director of Service as soon as possible.

Important Centricity PACS 4.0 SP10 supports the Archive Interface Module (AIM). The AIM software runs either on the Enterprise Archive (EA) server or, if the site does not have EA, on a standalone AIM server. If a pre-4.0 SP10 site uses either EA or the GE Application Service Provider (GE ASP) archiving service, the site will need to acquire a standalone server to run AIM. The AIM software must be configured on the EA server or a standalone EA server before the PACS upgrade is completed.

PowerPath Users Upgrading to Red Hat 5.8 will break the configuration of your PowerPath drivers. To restore the multipathing connection, you will need to reinstall the PowerPath drivers. Make sure you are prepared to do this after the Red Hat 5.8 upgrade is complete.

Table 2-2: Hardware and Software Compatibility with Centricity PACS 4.0 SP10

Function or Component

Hardware Operating System

IMS HP DL360 G5 Internal Quad Core (Linux OS)HP DL360 G6 Internal (Linux OS)HP DL580/360 G5 SAN Quad Core (Linux OS)HP DL360 G6 SAN (Linux OS)HP DL370 G6 Internal Quad Core (Linux OS)HP DL360 G7 Internal Quad Core (Linux OS)HP DL360 G7 SAN Quad Core (Linux OS)HP DL580 G7 SAN Quad Core (Linux OS)HP DL580 G7 Quad Core IO accelerator (Linux OS)HP DL360 G8 IMS Quad Core (Linux OS)HP DL360 G8 IMS SAN Dual Quad Core (Linux OS)HP DL350 G8 IMS Dual Quad Core (Linux OS)HP DL560 G8 Six Core Internal or External SSD

Dell PE6800 Internal Dual Core (Linux OS)Dell R710 MD1000 Quad Core (Linux OS)Dell R900 SAN Quad Core (Linux OS)Dell R610 IMS Internal Quad Core (Linux OS)Dell R610 IMS SAN Quad Core (Linux OS)Dell T710 Internal Quad Core (Linux OS)Dell R810 SAN Quad Core (Linux OS)Dell R620 IMS Internal Quad Core (Linux OS)Dell R620 IMS SAN Dual Quad Core (Linux OS)Dell T620 IMS Internal Dual Quad Core (Linux OS)

Linux 5.8

2085198-001 14

Page 15: C40_CRN_2085198-001sp10

Chapter 2 System Requirements

IMS Replication HP DL580 Quad G5 Internal (Linux OS)HP DL580\360 Quad (SAN) G5 (Linux OS)HP DL360 G6 (SAN) (Linux OS)HP DL360 G7 (Internal or SAN) Quad Core (Linux OS)HP DL370 G6 Internal Quad Core (Linux OS)HP DL580 G7 (SAN) (Linux OS)HP DL580 G7 Quad Core IO accelerator (Linux OS)HP DL360 G8 IMS Quad Core (Linux OS)HP DL360 G8 IMS SAN Dual Quad Core (Linux OS)HP DL350 G8 IMS Dual Quad Core (Linux OS)

Dell PE6800 Internal Dual CoreDell R610 IMS Internal Quad Core (Linux OS)Dell R610 IMS SAN Quad Core (Linux OS)Dell T710 Internal Quad Core (Linux OS)Dell R810 SAN Quad Core (Linux OS)Dell R620 IMS Internal Quad Core (Linux OS)Dell R620 IMS SAN Dual Quad Core (Linux OS)Dell T620 IMS Internal Dual Quad Core (Linux OS)

Linux 5.8

DAS HP DL360 (Dual) G5 (Linux OS)HP DL360 (Quad) G5 (Linux OS)HP DL360 G6 (Linux OS)HP DL360 G7 (6 Core) (Linux OS)HP DL360 G8 (6 Core) (Linux OS)

Dell R610 (Quad Core) (Linux OS)Dell R610 (Six Core) (Linux OS)Dell R620 (Six Core) (Linux OS)

Linux 5.8

IV HP DL360 (Dual) G5 + SAN (Linux OS)HP DL360 (Quad) G5 + SAN (Linux OS)HP DL360 G6 + SAN (Linux OS)HP DL360 G7 (6 Core) + SAN (Linux OS)HP DL360 G8 (6 Core) + SAN (Linux OS)HP NAS

Dell R610 (Quad Core) (Linux OS)Dell R610 (Six Core) (Linux OS)Dell R620 (Six Core) (Linux OS)Dell NAS

Linux 5.8

Table 2-2: Hardware and Software Compatibility with Centricity PACS 4.0 SP10 (Continued)

Function or Component

Hardware Operating System

2085198-001 15

Page 16: C40_CRN_2085198-001sp10

Chapter 2 System Requirements

DAS/IV HP DL360 (Dual) G5 (Linux OS)HP DL360 (Quad) G5 (Linux OS)HP DL360 G6 (Linux OS)HP DL360 G7 (6 Core) (Linux OS)HP DL360 G8 (6 Core) (Linux OS)

Dell R610 (Quad Core) (Linux OS)Dell R610 (Six Core) (Linux OS)Dell R620 (Six Core) (Linux OS)

Note: AIM must be implemented on the HP DL360 dual- or quad-core G5.

Linux 5.8

CDPS HP DL360 (Dual, Quad) G5 (Windows Server OS)HP DL360 G6 (Windows Server OS)HP DL360 G7 (6 Core) (Windows Server OS)HP DL360 G8 (6 Core) (Windows Server OS)

Dell R610 (Quad Core) (Windows Server OS)Dell R610 (Six Core) (Windows Server OS)Dell R620 (Six Core) (Windows Server OS)

Windows Server 2003Windows Server 2008

C2C / ITS HP DL360 G4 (Linux OS)HP DL360 (Dual) G5 (Linux OS)HP DL360 (Quad) G5 (Linux OS)HP DL360 G6 (Linux OS)HP DL360 G7 (6 Core) (Linux OS)HP DL360 G8 (6 Core) (Linux OS)

Dell R610 (Quad Core) (Linux OS)Dell R610 (Six Core) (Linux OS)Dell R620 (Six Core) (Linux OS)

Linux 5.8

DB Replication Server HP DL360 (Dual) G5 (Sybase 15) (Linux OS)HP DL360 (Quad) G5 (Sybase 15) (Linux OS)HP DL360 G6 (Sybase 15) (Linux OS)HP DL360 G7 (Sybase 15) (Linux OS)HP DL360 G8 (Sybase 15) (Linux OS)

Dell R610 (Quad Core) (Linux OS)Dell R610 (Six Core) (Linux OS)Dell T710 (Quad Core) (Linux OS)Dell R620 (Six Core) (Linux OS)

Linux 5.8

HL-7 Interface

Broker Agfa Broker 2.0 SP2 & SP3 See your vendor’s documentation.

Table 2-2: Hardware and Software Compatibility with Centricity PACS 4.0 SP10 (Continued)

Function or Component

Hardware Operating System

2085198-001 16

Page 17: C40_CRN_2085198-001sp10

Chapter 2 System Requirements

1-4: Browser Support for Centricity PACS

Table 2-3 shows the browsers supported in this release of Centricity PACS.

Note: When you launch a Centricity PACS tool in your browser, you may be prompted to download and install the required Java plug-in. Follow the prompts on your screen. Disregard any security messages that may appear.

Note: See “Browser Behavior When Using the Centricity Administration Tool” on page 43 for minor browser-dependent issues.

CCG 5.x HP DL3x0 G4, (Dual, Quad) G5, G6 See the Centricity Clinical Gateway for PACS Installation Manual for this release of CCG.

CCG 8.0.1 HP DL360 G7 (Windows Server OS)Dell R610 (Windows Server OS)Dell R710 (Windows Server OS)

See the Centricity Clinical Gateway for PACS Installation Manual for this release of CCG.

CCG 8.0.2.1 HP DL360 G7 (Windows Server OS)HP DL360 G8 (Windows Server OS)Dell R610 (Windows Server OS)Dell R620 (Windows Server OS)Dell R710 (Windows Server OS)

See the Centricity Clinical Gateway for PACS Installation Manual for this release of CCG.

CCG 9.2.1 HP DL360 G8 (Windows Server OS) See the Centricity Clinical Gateway for PACS Installation and Upgrade Manual for this release of CCG.

F5 BIG-IP for DB Replication / Load Balancing

1500 (v9.3.1-81.1-HF8)1600 (v9.4.8-407.0-HF4)1600 (v10.2.3 112.0)3400 (v9.3.1-81.1-HF8)3600 (v9.4.8-407.0-HF4)3600 (v10.2.3 112.0)

N/A

Table 2-2: Hardware and Software Compatibility with Centricity PACS 4.0 SP10 (Continued)

Function or Component

Hardware Operating System

Table 2-3: Browsers Supported for Centricity PACS Tools

Tool or Component Browser

Centricity Administration (CA) Centricity Exam Manager (web client) Flamingo Command Center Remote Host Administration (RHA) RA1000 Workstation and Exam Manager Online Help Servers Service Online Help (includes help for both Flamingo and RHA) System Administrator Online Help (CA online help)

Internet Explorer 8–11 Chrome 33.x Firefox 27.x Opera 19.x Safari 5.x

2085198-001 17

Page 18: C40_CRN_2085198-001sp10

Chapter 2 System Requirements

1-5: C2C Server Compatibility

In Centricity PACS 4.0 SP10, Centricity to Centricity (C2C) servers are supported between PACS 4.0 SP10 to PACS 4.0 SP10.

Transfers between PACS 4.0 SP10 and other versions are not supported.

1-6: Java 1.7 Support

With this release, Centricity PACS supports Java 1.7 for the following component:

RA1000

1-7: SPINE Authentication

Centricity PACS 4.0 SP10 does not support SPINE authentication.

SPINE consists of security features used in the Centricity PACS Workstation and Exam Manager that include Single Sign On (SSO) and Exam Access: Legitimate Relationship and Patient Consent [or Patient Demographics Services (PDS)].

Note: SPINE security is not available in some markets.

1-8: Virtual Machine Requirements

Centricity PACS 4.0 SP10 supports installation and deployment of the IMS and other servers in a virtual environment.

Important Supporting Centricity PACS components in a VM environment requires customer VM expertise and a customer VM environment.

Note: The use of “VMware” and other vendor-specific references are for example only; equivalent virtual machine environments are supported.

Servers must be capable of supporting a 64-bit operating system.

Table 2-4: Minimum Hardware Requirements for Centricity PACS Servers

Function CPU Type # CPUs x# Cores/CPU

Disk Space Memory

VMware ESXi Server x86–64 16 2 x 74GB (RAID1) 16 GB

VMware vCenter Server x86 2 2 x 74GB (RAID1) 2 GB

2085198-001 18

Page 19: C40_CRN_2085198-001sp10

Chapter 2 System Requirements

1-8-1: Memory Requirements

Virtual memory needs a 1-to-1 relationship to physical memory. For example, if you install a database server and two nodes, the physical servers would require 24 GB (3 servers x 8 GB RAM). Therefore, the virtual memory of those VMs is also 24 GB, and physical memory of the VM farm is 24 GB.

Note: You can add additional VMs to your VM farm; however, performance degradation may occur if you overextend physical RAM.

Note: Centricity PACS does not support oversubscription of hardware resources in a virtual environment.

1-8-2: CPU Requirements

Virtual CPUs do not always need a 1-to-1 relationship with the physical CPUs as is the case with RAM. Depending on CPU performance (CPU speed), additional virtual CPUs may be required to perform the same processes as CPUs with higher CPU speed.

Note: Red Hat Linux 5.8 is required if the server uses the AMD Opteron 6000-series chip set in a VMware virtual environment.

1-8-3: Network Requirements

Virtual NICs replace physical NICs. In a non-VM environment, 2 physical NICs are required. In a VM environment, 1 virtual NIC replaces both physical NICs.

Table 2-5: Basic VM Configuration for Centricity PACS Servers

Server Type CPU Memory NIC

DAS 2 CPU (2.0 Ghz each) 4 GB 1x VMXNET 3

CDPS 2 CPU (2.0 Ghz each) 4 GB 1x VMXNET 3

IMS XLDB (100 GB) 4 CPU (2.0 Ghz each) 16 GB 1x VMXNET 3

IMS XXLDB (300 GB) 8 CPU (2.0 Ghz each) 32 GB 1x VMXNET 3

IMS XXLDB (550 GB) 16 CPU (2.0 Ghz each) 32 GB 1x VMXNET 3

IMS XXXLDB (800 GB) 16 CPU (2.0 Ghz each) 64 GB 1x VMXNET 3

IMS XXXXLDB (1050 GB) 16 CPU (2.0 Ghz each) 64 GB 1x VMXNET 3

2085198-001 19

Page 20: C40_CRN_2085198-001sp10

Chapter 2 System Requirements

1-8-4: VMware Compatibility

For information about setting up a virtual PACS environment, see the Centricity PACS Servers Installation and Upgrade Manual for this release of Centricity PACS.

Table 2-6: VMware Compatibility with Centricity PACS 4.0 SP10

Centricity PACS Function or Component

Operating System

IMS (Production and Test) Linux 5.8

DAS Linux 5.8

DAS-IV Linux 5.8

ITS Linux 5.8

DB Replication Linux 5.8

Coordination Module Linux 5.8

EA 4.0 Windows Server 2008

CDPS Windows Server 2008

CCG 8.0.1, 8.0.2.1, 9.2.1 See the Centricity Clinical Gateway for PACS Installation and Upgrade Manual for the version of CCG.

C2C Linux 5.8

SPS Windows Server 2003

PACS Health Windows Server 2008

Mobil Access 4.0

Note: Only 2D

Linux 6.4

Analytics 1.1 Windows Server 2008

2085198-001 20

Page 21: C40_CRN_2085198-001sp10

Chapter 2 System Requirements

Section 2: RA1000 Workstation

2-1: System Requirements

2-2: Software Compatibility

2-2-1: Operating System

Following are Windows operating systems compatible with this release of Centricity PACS RA1000.

Table 2-7: Hardware Requirements for Centricity RA1000

CPU Type CPU Disk Space Memory

Minimum x86 2 74 GB 1 GB

Recommended x86–64 2 74 GB 3 GB

Table 2-8: Minimum System Requirements by Workstation Type

Workstation Type CPU Memory Other

PACS workstation* 1 dual core (2GHz)[1 quad core (2.5GHz) recommended]

2 GB(3 GB recommended)

Gigabit ethernet

RIS-IC/PACS integrated workstation

1 dual core (2.66GHz)[1 quad core (2.5GHz) recommended

1 GB(3 GB recommended)

Gigabit ethernet

RIS-IC/PACS integrated workstation with Extends

2 dual core (2.66GHz)[1 quad core (2.5GHz) recommended

2 GB(3 GB recommended)

Gigabit ethernet

*Standard configuration includes (1) two high-resolution diagnostic portrait monitors (A+, A, B+, B models) plus one or two clinical landscapemonitors (C models), or four portrait monitors plus one or two landscape monitors, or one or two landscape monitors; (2) color servicemonitor for specialized maintenance tasks; and (3) computer, mouse, keyboard, and associated cabling.

Table 2-9: Windows OS Compatibility with Centricity RA1000

Windows OS Comment

Windows 8 (64-bit) Internet Explorer 10 or later is required by Microsoft Although Centricity RA1000 is compatible with Windows 8, video

drivers may not be available from the display vendor.

2085198-001 21

Page 22: C40_CRN_2085198-001sp10

Chapter 2 System Requirements

2-2-2: Applications

Table 2-1 lists the PACS-supported applications compatible with this release of Centricity RA1000.

Windows 7 (32-bit or 64-bit) with Internet Explorer 6, 7, or 8

Professional, Ultimate, or Enterprise for 32-bit applications in 32- or 64-bit mode running JRE version jre1.6.0_20

RA1000 runs as a 32-bit process on 64-bit OS Limited support on Ultimate, Professional, Home Version AW Suite 2.0.4.x is required Multiple WDDM video drivers and video card vendors may be

used (e.g., ATI 3800 Clinical video card used with Barco 5450 Diagnostic video card)

Windows XP SP3 (32-bit) with Internet Explorer 6, 7, or 8

Windows XP (64-bit) with Internet Explorer 6, 7, or 8

Note: Windows XP is no longer supported by Microsoft.

RA1000 runs as a 32-bit process on 64-bit OS AW Suite 2.0.3 is required for 64-bit OS Customer-supplied Windows XP 64-bit (OS not available on Dell

T3600, Dell T5600, Dell T7600, HP Z420, HP Z620, or HP Z820)

Table 2-9: Windows OS Compatibility with Centricity RA1000 (Continued)

Windows OS Comment

Table 2-10: Integration with Centricity RA1000 4.0 SP10

Application Application Version 32-bit RA1000 64-bit RA1000

AW Server 2.0.5, 2.0.6, 2.0.9, 2.0.11 Yes Yes

AW Suite 1.0.4, 2.0.x

Note: AW Suite 2.0.3 or above is required when using Windows XP 64 bit. AW Suite 2.0.4 or higher is required for Windows 7.

Yes No

PowerScribe 4.6 SP2, 4.7 SP1b, 4.8 SP1, 5.0.1.3

Warning: When using the PowerScribe Extend integration with PACS, PowerScribe version 5.0.1.3.1 or higher is strongly recommended with PACS 3.1.1.2 or higher.

Note: When using this PACS release with PowerScribe version 5.0 SP1, saving dictation and not saving dictation are the choices when closing an exam during an interrupted workflow. When using this PACS release or earlier with PowerScribe versions prior to PowerScribe 5.0 SP1, saving dictation, not saving dictation, and canceling dictation are the options when closing an exam during an interrupted workflow.

Yes No

2085198-001 22

Page 23: C40_CRN_2085198-001sp10

Chapter 2 System Requirements

PowerScribe 360 with IDR only

1.5 (build 4.5.8a); 2.0 (build 5.0.6.0); 2.5 (build 5.5.3.0)

Note:

PowerScribe 360 is only supported using the IDR extend.

PowerScribe 360 is only supported in Centricity PACS 4.x.

PowerScribe 360 2.0 and 2.5 are only supported in Centricity PACS 4.0 SP3, 4.0 SP5, and 4.0 SP10.

Yes Yes

Integrated Desktop Reporting (IDR)

1.0 Yes Yes

RIS-IC 10.5, 10.6, 10.7, 10.8

Approved for: RIS-driven workflow with or without Centricity

Precision Reporting PACS-driven workflow with or without Centricity

Precision Reporting with UP5 and above Centricity Precision Reporting with UP5 and

above RIS-driven workflow or PACS-driven workflow

without Centricity Precision Reporting with UP6 and above.

Yes Yes

Generic Extend 1.0.1 (1.0 SR1) Yes Yes

Talk 3.2, 4

Note: Agfa TalkStation Radiology 3.2 is the required minimum version. Any integration with earlier versions of Agfa TalkStation must be upgraded.

Yes No

Lanier SpeechQ 1.2, 1.3 Yes Yes

Cerner RadNet 7.8 (April 2002) Yes Yes

RISi (Medora) 4.2.x, 5.0.x Yes No

Centricity Web DX 2.1, 2.2 N/A N/A

Dictaphone Not versioned N/A N/A

Boomerang Not versioned N/A N/A

Centricity Web 3.0.6 or higher (excluding 4.0)

Note: Centricity PACS is not compatible with Centricity Enterprise Web 4.0.

N/A N/A

Table 2-10: Integration with Centricity RA1000 4.0 SP10 (Continued)

Application Application Version 32-bit RA1000 64-bit RA1000

2085198-001 23

Page 24: C40_CRN_2085198-001sp10

Chapter 2 System Requirements

2-3: Hardware Compatibility

Caution: Hardware supplied by customers must meet all applicable standards listed under the “Certifications” section in the Centricity PACS RA1000 Workstation and Exam Manager Operator Manual for this release of Centricity PACS.

Important Before installing or upgrading, verify that your site hardware meets Centricity PACS compatibility requirements. If your site's hardware is not listed in this section, escalate to your director of service as soon as possible.

Centricity Enterprise Archive (EA)

3.0.11 (with integrated AIM or standalone AIM 3.0); 4.0EA 3.0 does not support the following SOP classes: 1.2.840.113543.6.6.1.3.10001 PhilipsLive3D01

(Philips HP Sonos 7500) 1.2.840.113543.6.6.1.3.10002 PhilipsLive3D02

(Philips HP Sonos 7500) 1.2.840.10008.5.1.4.1.1.66 Raw Data Storage 1.2.840.10008.5.1.4.1.1.13.1.3 Breast

Tomosynthesis Image Storage 1.2.840.10008.5.1.4.1.1.88.40 Procedure Log 1.2.840.10008.5.1.4.1.1.88.67 X-Ray Radiation

Dose SR

N/A N/A

Centricity RIS 2.2.x

Note: Contact your GE representative about migrating to Centricity RIS-IC.

No No

PACS Health Not versioned N/A N/A

CRMA 1.0, 1.1/2.0, 3.1, 4.0 N/A N/A

Universal Viewer 5.0, 5.0 SPx Yes Yes

FCE/RPPS Conversion Tool

The tool is independent of Centricity PACS software releases.

N/A N/A

Table 2-10: Integration with Centricity RA1000 4.0 SP10 (Continued)

Application Application Version 32-bit RA1000 64-bit RA1000

Table 2-11: Hardware Compatibility with Centricity RA1000

Manufacturer / Model Comment

Dell T5400Dell T5500HP Z600HP Z400

Supported only if the workstation and video card(s) are supported by Windows XP SP3 or Windows 7

2085198-001 24

Page 25: C40_CRN_2085198-001sp10

Chapter 2 System Requirements

For hardware specifications and upgrade support, see your workstation manufacturer’s documentation.

2-3-1: Video Cards

Dell T3600Dell T5600Dell T7600HP Z420HP Z620HP Z820

Requires Windows 7

Table 2-11: Hardware Compatibility with Centricity RA1000 (Continued)

Manufacturer / Model Comment

Table 2-12: Video Cards Supported by RA1000

Video Card Windows XP1 Windows 72 Windows 83

NVIDIA Quadro NVS 280 PCI-e Y N N

NVIDIA Quadro 4 285 NVS PCI-e Y N N

NVIDIA Quadro NVS 290 Y N N

BarcoMed 2 MP 2FH (P/N: KM570052) Y N N

BarcoMed 3 MP 2FH (P/N: KM900051) Y N N

BarcoMed 5 MP 2FH (P/N: KM570991)4,5

Y N N

BarcoMed Coronis 2/3/5 MP (P/N: 2 MP, KM570070; 3 MP, KM570071; 5 MP, KM570072)

Y N N

ATI V3700, 3750 Y N N

ATI V3800, 4800 Y Y Y

ATI V3900 Y Y Y

ATI V58006 Y Y Y

ATI V79006 Y Y Y

Barco MXRT-1150 Y Y N

Barco MXRT-2150 Y Y N

Barco MXRT-2400 Y Y Y

Barco MXRT-5100 Y N N

2085198-001 25

Page 26: C40_CRN_2085198-001sp10

Chapter 2 System Requirements

1The OEM no longer supports Windows XP.2 Professional, Ultimate, or Enterprise edition (32 bit or 64 bit).3Centricity PACS RA1000 is compatible with Windows 8; however, video drivers may not be available from the display vendor.4Centricity PACS RA1000 workstations running on Windows 7 and using 5 MP displays for mammography or tomography reading must use the MXRT-7400/7500 video card.5In a mammography configuration, the video card is paired with the monitor set.6Use with Eizo monitors.7Supports MXRT-1150/-2150/-5200/-7300 when these boards are combined with an MXRT-x4xx or MXRT-x5xx board.8IW only.9UV, RA600, RA1000.

Barco MXRT-5200 Y Y N

Barco MXRT-54004 Y Y Y

Barco MXRT-54504 Y Y Y

Barco MXRT-55004 N Y Y

Barco MXRT-55504 N Y Y

Barco MXRT-73004,7 Y Y Y

Barco MXRT-7400 Y Y Y

Barco MXRT-7500 N Y Y

Matrox RAD LPX PCI-e (Eizo) Y Y N

Matrox Xenia (Eizo)8 Y Y N

EIZO MED V5800 card N Y N

EIZO MED V7900 card N Y N

EIZO MED-X50009 N Y N

EIZO MED-X60009 N Y N

EIZO MED-X70009 N Y N

Table 2-12: Video Cards Supported by RA1000 (Continued)

2085198-001 26

Page 27: C40_CRN_2085198-001sp10

Chapter 3 Release Content

This chapter includes:

Section 1: Features and Enhancements Effective with Centricity PACS 4.0 SP10. . . . . 27

Section 2: Issues Resolved in Centricity PACS 4.0 SP10. . . . . . . . . . . . . . . . . . . . . . . . 31

Section 3: Upgrade Paths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

Section 1: Features and Enhancements Effective with Centricity PACS 4.0 SP10

1-1: RA1000 Workstation

1-1-1: Display Structured Notes by Default When an Exam Is Opened

With this release, the Structured Reports tab in the Notes window can be displayed by default when an exam is opened. This behavior is enabled by selecting Structured Reports for the Automatically Display Notes When Opening an Exam option (Utilities > Preferences > System Preferences > Exam Opening Options).

For more information, see the “Setting Notes Preferences” section in the Exam Notes, Key Image Notes, and Structured Reports chapter of the RA1000 Workstation and Exam Manager Operator Manual.

1-1-2: Platinum Properties to Display Notes When an Exam Is Opened

In the Exam Opening Options (Utilities > Preferences > System Preferences), if the note type (e.g., Structured Reports) selected by a user cannot be displayed by default when an exam is opened (either because the exam does not contain the note type or because the user does not have the privilege to view the note type), the following Platinum property can override the user preference settings:

com.ge.med.newman.gui.userprefs.ViewPreferencePanel.overrideNoteTabSelectionOnNoteUnavailability=

Where:

true (default) = display the note type that the user can view and for which notes exist when an exam is opened

false = do not display the Notes window when an exam is opened

If there is no default selection when the property above is set to true, a new exam note can be created by default (even if automatically displaying exam notes is not enabled; i.e., com.ge.med.newman.gui.userprefs.ViewPreferencePanel.autoDisplayExamNotes=false) if the user has the privilege to create exam notes:

2085198-001 27

Page 28: C40_CRN_2085198-001sp10

Chapter 3 Release Content

com.ge.med.rumba.desktop.ui.examnotes.controller.ExamNotesController.autoDisplayCreateExamNote=

false (default) = do not open a new exam note in the Notes window

true = open a new exam note in the Notes window

For more information about Platinum properties, see the “Displaying Notes by Default When an Exam Is Opened” section in the Workstation Feature Configuration chapter of the Centricity PACS Workstation Installation and Service Manual.

1-1-3: Thumbnail Reflects WW/WL Applied to Image

With this release, the window/level that the user applies to a full-sized image in RA1000 are reflected in the thumbnail image in the Navigator after the user saves the changes.

Note: Window/level changes are specific to the user and the thumbnail. The window/level changes to do not affect the presentation state of the image.

1-1-4: Specifying Precision of ROI Statistics on MR Functional Maps

With this release, Platinum properties enable specifying the precision of ROI statistics displayed on functional maps for MR images.

ROI statistics [DICOM tag (0028,1053)] are displayed in either exponential (the default) or decimal format based on the following platinum property:

com.ge.med.platinum.gui.image.notare.user.roi.ROIStatistics.DisplayDecimalValue=

Where:

false (default) = display ROI statistics on functional maps in exponential format

true = display ROI statistics on functional maps in decimal format

If decimal format is specified, then the decimal precision (range 1–10) is set with platinum properties for the average pixel, standard deviation, minimum pixel, and maximum pixel.

For more information, see the “Configuring Precision ROI Statistics on Functional Maps” subsection in the “Configuring Region of Interest (ROI)” section in the Workstation Feature Configuration chapter of the Workstation Installation and Service Manual for this release of Centricity PACS.

1-1-5: Property to Synchronize Reporting System and RA1000 Worklist Selection (Browse Mode)

With this release, a new Platinum property with its default setting (true) ensures that context is maintained between the reporting system and RA1000 worklist (Browse mode) when an exam is selected (highlighted).

com.ge.med.rumba.desktop.component.worklist.SyncVRwithWL=true

2085198-001 28

Page 29: C40_CRN_2085198-001sp10

Chapter 3 Release Content

Note: A reporting system window no longer opens in the foreground when an exam is selected (highlighted) in the worklist.

For more detail, see “Synchronizing the Reporting System and RA1000 Worklist Selection (Browse Mode)” on page 46.

1-1-6: Study Description Added to DICOM Query Retrieve

As of the 4.0 SP7 Centricity PACS release, you can select exams using the Study Description field in the DICOM Query Retrieve dialog box.

1-1-7: Support for Standard Secondary Capture Images from SR Modalities

With this release, a property in the DAS configuration file (das.config) supports storing and displaying standard secondary capture images [SOP class UID STANDARD_SEC_CAPTURE (1.2.840.10008.5.1.4.1.1.7)] from structured report (SR) modalities. This capability enables Centricity PACS to accept, for example, dose radiation reports of this SOP class from SR modalities.

For more detail, see your GE support representative.

1-1-8: Filtering Out Images Not Supported for Display

With this release, a new Platinum property enables RA1000 to filter out images not supported for display. Filtering occurs on a per image basis and is in addition to the supported modality configuration information at the exam level.

com.ge.med.platinum.work.isu.ExamTransaction.hideNonSupportedImages=

Where:

false (default) = If one or more images in an exam are not supported for display, the following message appears:

Image Type Not Supported for Display

true = filter out images not supported for display

Note: Filtering out images not supported for display suppresses both the DICOM header information and the “Image Type Not Supported for Display” message.

Note: Hanging protocols (DDP) may require modification if they account for display of the message.

If only one exam is open and no images in the exam are supported for display, the following message appears:

The exam failed to display Image Type Not Supported for Display

If more than one exam is open, and in the currently selected exam, no images are supported for display, the following message appears:

2085198-001 29

Page 30: C40_CRN_2085198-001sp10

Chapter 3 Release Content

The exam failed to display Image Type Not Supported for DisplayReverting to last opened exam

For more information, see the “Configuring Image Display Options” section in the Workstation Feature Configuration chapter of the Centricity PACS Workstation Installation and Service Manual.

1-2: Centricity PACS Servers

1-2-1: More DICOM SOP Classes Supported

With this release, the Centricity PACS DICOM application server (DAS) supports additional SOP storage classes.

For more information about DAS and SOP classes, see the Centricity PACS Servers Service Manual.

1-2-2: Solid-State Drive (SSD) Servers for IMS

With this release, Centricity PACS supports IMS deployment on the HP DL560 G8 SSD 400 server and compatible SSD servers from other vendors.

1-2-3: ATNA Logging

With this release, Centricity PACS supports Audit Trail and Note Authentication (ATNA) logging in conjunction with Universal Viewer.

Table 3-1: SOP Storage Classes

Name UID

MR Spectroscopy Storage 1.2.840.10008.5.1.4.1.1.4.2

Enhanced US Volume Storage 1.2.840.10008.5.1.4.1.1.6.2

Enhanced XA Image Storage 1.2.840.10008.5.1.4.1.1.12.1.1

Intravascular Optical Coherence Tomography Image Storage - For Presentation

1.2.840.10008.5.1.4.1.1.14.1

Intravascular Optical Coherence Tomography Image Storage - For Processing

1.2.840.10008.5.1.4.1.1.14.2

Segmentation Storage 1.2.840.10008.5.1.4.1.1.66.4

Real World Value Mapping Storage 1.2.840.10008.5.1.4.1.1.67

2085198-001 30

Page 31: C40_CRN_2085198-001sp10

Chapter 3 Release Content

Section 2: Issues Resolved in Centricity PACS 4.0 SP10

The table below contains issues resolved in Centricity PACS 4.0 SP10. Issues are listed numerically by reference number.

Table 3-2: Resolved Issues in Centricity PACS 4.0 SP10

Issue Reference Number and Description

Reference Number: 5107680

Problem:

Add information to the Centricity PACS Servers Service Manual about using CAM when a site is configured for eView (global STS).

Resolution:

With this release, the Cache Manager and Orphan Monitor chapter in the Centricity PACS Servers Service Manual is revised as follows:

In the “Editing CAM Configuration Settings” section, a note is added after Step 2:

Note: If the site is configured for eView, do not run CAM on the global STS; run it only on the local STS.

In the “Cache Monitor Page - Config Display” section, a note is added after the Nap Time parameter:

Note: If a site is configured with eView (global STS), more than one iteration may be needed before an exam is flushed by CAM.

Reference Number: 5468283

Problem:

After a user logged in to Centricity Exam Manager (CEM), the wrong domain was displayed for the user.

Resolution:

With this release, the OVERRIDE DEFAULT AUTHORITY NAME parameter specifies whether the DEFAULT AUTHORITY NAME (globally assigned domain) is overridden by the Assigning Authority (domain assigned to the user) when the user logs in to CEM. The default is “N” (No).

For more information, see OVERRIDE DEFAULT AUTHORITY NAME in the “Client Workstation Configuration Settings” table in the Client Configuration chapter of the Centricity PACS System Administrator Online Help Manual.

2085198-001 31

Page 32: C40_CRN_2085198-001sp10

Chapter 3 Release Content

Reference Number: 8963853

Problem:

If a user opened and then quickly closed an exam (with Save on Close enabled), closing the exam took an abnormal amount of time because RA1000 had to complete loading the exam images before it could save and close the exam.

Resolution:

With this release, when Save on Close is enabled, RA1000 saves an exam before closing it only if the user modifies the exam.

Reference Number: 13294515

Problem:

RA1000 did not support view codes R-1024A (XCCL–exaggerated lateral craniocaudal) or R-1024B (XCCM– exaggerated medial craniocaudal) for mammography views.

Resolution:

With this release, RA1000 supports both new codes (R-1024A and R-1024B) and deprecated codes (Y-X1770 and Y-X1770) for XCCL and XCCM mammography views, respectively.

Reference Number: 13697549

Problem:

The Event Notification Monitor (ENM) did not issue a notification when a user logged in to a workstation.

Resolution:

With this release, the ENM generates a notification when a user logs in to a workstation.

Reference Number: Not available

Problem:

The Centricity DICOM Print Server (CDPS) did not support new codes (R-1024A and R-1024B) for XCCL and XCCM mammography views, respectively.

Resolution:

With this release, CDPS supports the new codes.

Table 3-2: Resolved Issues in Centricity PACS 4.0 SP10 (Continued)

Issue Reference Number and Description

2085198-001 32

Page 33: C40_CRN_2085198-001sp10

Chapter 3 Release Content

Reference Number: Not available

Problem:

In the Centricity PACS Servers Installation and Upgrade Manual, in the Rebaselining and Upgrading a PACS Pre-3.2 Replication System chapter, in the “Replication upgrade showing downtimes” illustration, the “Run APP_NET config REPSITEB” step was out of order: REPSITEB must be on the network and have a valid hostname and IP address when the “Config Coordmod Server via RHA” step is executed.

Resolution:

With this release, the Centricity PACS Servers Installation and Upgrade Manual was revised as follows:

In the Rebaselining and Upgrading a PACS Pre-3.2 Replication System chapter, in the “Replication upgrade showing downtimes” illustration, the “Run APP_NET config REPSITEB” step was moved between the “APPS on REPSITEB” and “Apps on both Coord / REP” steps.

In the Pre-Upgrade Planning chapter, in the “Estimated Time Required to Upgrade a Database Replication System” table, the “Run APP_NET config on REPSITEB” row was moved between the “Config applications REPSITEB” and “Application install Coordmod / Replication servers” rows.

Reference Number: Not available

Problem:

When using integrated desktop reporting (IDR) with PowerScribe, if the user discarded (or closed without saving) a report, the exam was closed, marked “Dictated,” and removed from the Dictate mode list in RA1000.

Resolution:

As of the 4.0 SP7 Centricity PACS release, when using the IDR with PowerScribe, if the user discards (or closes without saving) a report, the exam is closed, its status is “Verified” (i.e., status is unchanged), and it remains in the Dictate mode list in RA1000.

Table 3-2: Resolved Issues in Centricity PACS 4.0 SP10 (Continued)

Issue Reference Number and Description

2085198-001 33

Page 34: C40_CRN_2085198-001sp10

Chapter 3 Release Content

Reference Number: Not available

Problem:

When retiring an IV at a site, the IV was flushed to 1% following proper procedures; thereafter, a user incorrectly deleted the remaining images manually.

Resolution:

The following note:

Caution: Never manually delete images from an Image Volume. If CAM fails to purgeimages from an IV, disposition of the remaining image files must be resolvedbefore moving or retiring the IV. Contact GE support for more information.

Is added to the these manuals:

Centricity PACS Servers Service Manual

In Cache Manager and Orphan Monitor chapter, after first paragraph in “CAM Overview” section.

In Image Volume and Short-Term Storage Management chapter, after first paragraph in “Storage Onion” section and at the top of “Removing a Device (IV) from an STS” section.

Centricity PACS System Administrator Online Help Manual

In the System Monitor chapter, after first paragraph in “Monitoring Storage Onion Layers” subsection in the “Storage Onion” section.

Reference Number: Not available

Problem:

When the database language was Danish and the user tried to create/search folder formats using the CA tool, no results were returned because the CA tool queried the Danish database with an English string.

Resolution:

With this release, the CA tool gets the Danish string from the database for queries.

Table 3-2: Resolved Issues in Centricity PACS 4.0 SP10 (Continued)

Issue Reference Number and Description

2085198-001 34

Page 35: C40_CRN_2085198-001sp10

Chapter 3 Release Content

Reference Number: Not available

Problem:

The Centricity PACS RA1000 Workstation and Exam Manager Operator Manual incorrectly stated that filter effects applied to an image were erased by cining through the series, adjusting the window/level, reloading a series, or closing/reopening an exam.

Resolution:

The following text is removed from the “Using Image Filters” section in the Image View Area chapter of the Centricity PACS RA1000 Workstation and Exam Manager Operator Manual:

If you perform any other actions on the images, the filter effects are erased. For example, the filter changes are erased if you:

Cine though the series. Adjust the window/level. Reload a series. Close and reopen an exam.

Reference Number: Not available

Problem:

The image displayed in RA1000 was “noisy” due to incorrect byte swapping from OB to OW by DAS.

Resolution:

With this release, byte swapping from OB to OW by DAS is now correct.

Reference Number: Not available

Problem:

When a third-party viewer displayed Centricity PACS images with spine-labeling annotations, the annotations contained meaningless characters.

Note: Centricity PACS conforms to DICOM standards. In RA1000, the DICOM tag ST (0070,0006), an unformatted text value, is implemented with delimiters. For this reason, a third-party viewer may display an annotation with the delimiters. For example, spine-labeling annotation “L1” may be rendered as "L1:~:0:~:0:~:" by a third-party viewer. The workaround is to manually delete or modify the DICOM tag.

Table 3-2: Resolved Issues in Centricity PACS 4.0 SP10 (Continued)

Issue Reference Number and Description

2085198-001 35

Page 36: C40_CRN_2085198-001sp10

Chapter 3 Release Content

Reference Number: Not available

Problem:

When setting up a remote archive destination using the CA tool, if “Archive” was chosen at Auto Send Reason, a nonarchived exam (lta_stat=N) sent to the destination had its lta_stat value set to “R” and was not archived to the PACS LTA. Because exams with lta_stat=R are targets for deletion by CAM during a purge, any nonarchived exam with lta_stat=R was a potential data loss.

Resolution:

In the Configuration chapter of the System Administrator Online Help Manual, in the “Destinations” section, the “Adding and Editing a Destination” section is revised as follows:

The introductory paragraph includes remote archives:

Destination sites are added to the IMS database for:

C2C transfers

Local query-retrieve devices

Remote archives

A caution note is added to the step to select an Auto Send Reason:

Caution: If you choose “Archive” for an Auto Send Reason to an archive destination, the status of any nonarchived exam (lta_stat=N) sent to the destination will be set to “R” (lta_stat=R), and the exam will not be archived to the PACS LTA. Because exams with lta_stat=R are targets for deletion by CAM during a purge, any nonarchived exam with lta_stat=R status is a potential data loss.

Reference Number: Not available

Problem:

Study-level information (such as accession number) that was modified using Centricity Exam Manager or via the RIS was not propagated to AW Server because the study identifiers used by Centricity web service differed from those used by other services to reconcile data.

Resolution:

With this release, Centricity web service uses standard identifiers to reconcile data across applications.

Table 3-2: Resolved Issues in Centricity PACS 4.0 SP10 (Continued)

Issue Reference Number and Description

2085198-001 36

Page 37: C40_CRN_2085198-001sp10

Chapter 3 Release Content

Reference Number: Not available

Problem:

The Configuring Language Support chapter in the Centricity PACS Servers Service Manual did not state that language configuration was also required on the client.

Resolution:

The following note is added at the beginning of the Configuring Language Support chapter of the Centricity PACS Servers Service Manual:

Note: This chapter describes how to configure language support on the Centricity PACS servers. To configure language support on RA1000 workstations, see the Language Configuration chapter in the Centricity PACS Workstation Installation and Service Manual. To configure language support for other clients, see the client and/or service documentation for the supported clients.

Reference Number: Not available

Problem:

In PowerScribe, after the user signs the report and quickly opens a new study, an out-of-context situation might occur.

Resolution:

With this release, a new study opens only if the study is no longer in a “pending” state in Centricity PACS.

Reference Number: Not available

Problem:

After merging patient exams using the web-based Centricity Exam Manager launched from RA1000, the font and background colors were the same in Lights Off skin in RA1000, making the text illegible.

Resolution:

A code fix resolved this issue. Information is displayed correctly when the Lights Off skin is used.

Reference Number: Not available

Problem:

The information about Centricity PACS in a VM environment was out of date.

Resolution:

With this release, the Setting Up a PACS Virtual Environment appendix in the Centricity PACS Servers Installation and Upgrade Manual is updated.

Table 3-2: Resolved Issues in Centricity PACS 4.0 SP10 (Continued)

Issue Reference Number and Description

2085198-001 37

Page 38: C40_CRN_2085198-001sp10

Chapter 3 Release Content

Reference Number: Not available

Problem:

In RA1000, switching among worklists with the same column widths resulted in the column widths changing.

Resolution:

With this release, switching among worklists does not affect the column widths.

Reference Number: Not available

Problem:

In the Centricity PACS Servers Service Manual, the “Setting up SFTP for Security Audit or ENM Log” section in the Database Maintenance and Administration chapter incorrectly referred to FTP as secure FTP (SFTP).

Resolution:

In the Centricity PACS Servers Service Manual, occurrences of “SFTP” are changed to “FTP.”

Reference Number: Not available

Problem:

In a Universal Viewer–AW Server integrated workflow, occasionally AW Server did not launch when an exam was opened.

Resolution:

As of the 4.0 SP7 Centricity PACS release, AW Server launches when an exam is opened in a Universal Viewer–AW Server integrated workflow.

Reference Number: Not available

Problem:

Using the Image Volume-STS Management feature of RHA to add a NAS IV to an STS failed if the STS name contained a space character.

Resolution:

With this release, adding a NAS IV to an STS using RHA succeeds regardless of a space character in the STS name.

Table 3-2: Resolved Issues in Centricity PACS 4.0 SP10 (Continued)

Issue Reference Number and Description

2085198-001 38

Page 39: C40_CRN_2085198-001sp10

Chapter 3 Release Content

Reference Number: Not available

Problem:

RIS-IC–PACS integration in a PACS-driven workflow failed because a Platinum extend property was set by default for a RIS-driven workflow:

com.ge.med.platinum.extend.extend2.idxWorklistDrivenMacro=true

Resolution:

With this release, the default value of the platinum extend property is false:

com.ge.med.platinum.extend.extend2.idxWorklistDrivenMacro=false

Set the value to true only for a RIS-driven workflow.

See “Platinum Extend Property Default in RIS-IC–PACS Integration” on page 47.

Reference Number: Not available

Problem:

The DICOM implementation version name was not updated in Centricity PACS.

Resolution:

With this release, Centricity PACS reflects the current DICOM Conformance implementation.

Reference Number: Not available

Problem:

Generated KOS via RA1000 did not include DICOM tag (0008,1111) Referenced Performed Procedure Step Sequence.

Resolution:

With this release, generated KOS via RA1000 includes DICOM tag (0008,1111).

Reference Number: Not available

Problem:

In Centricity PACS–LDAP integration, if LDAP passwords were not persistent, users could not log in to AW Server from RA1000.

Resolution:

With this release, a web service call authenticates LDAP passwords (both persistent and nonpersistent) when users log in to AW Server from RA1000. The mt_port parameter in the /usr/local/awspacswebsrv/config/config_ws.properties file specifies the port for logging in to AW Server from RA1000. The default port is 80.

Table 3-2: Resolved Issues in Centricity PACS 4.0 SP10 (Continued)

Issue Reference Number and Description

2085198-001 39

Page 40: C40_CRN_2085198-001sp10

Chapter 3 Release Content

Reference Number: Not available

Problem:

In Centricity PACS 4.0 SP5, the release notes stated that the Launch QC Tool button, which starts RA600 from the Patient Information tab of Centricity Exam Manager (CEM) in RA1000, could be configured to launch other QC tools.

Resolution:

With this release, the error is corrected. See “QC Tool Button Is Not Configurable” on page 46.

Reference Number: Not available

Problem:

During installation of the Centricity PACS IMS, the generic addlogin script for Sybase Adaptive Server Enterprise (ASE) was overridden by the addlogin script for a specific version of ASE.

Resolution:

A code fix resolved this issue: The generic addlogin script for ASE is not overridden.

Reference Number: Not available

Problem:

Centricity PACS documentation and the Extends online help refer to OrthoVew 2.0.6 extend, which the vendor no longer supports.

Resolution:

With this release, in the Workstation Installation and Service Manual, the following sentence replaces the content in the “OrthoView” section of the Extends Installation appendix:

OrthoView no longer supports the OrthoView 2.0.6 extend.

All other references to the OrthoView extend are removed from the Centricity PACS documentation and Extends online help.

Reference Number: Not available

Problem:

C-FIND return of series and study information included empty or rejected or series in the counts.

Resolution:

With this release, empty or rejected series are not counted in C-FIND return of information.

Table 3-2: Resolved Issues in Centricity PACS 4.0 SP10 (Continued)

Issue Reference Number and Description

2085198-001 40

Page 41: C40_CRN_2085198-001sp10

Chapter 3 Release Content

Reference Number: Not available

Problem:

In RHA, a nameless STS volume could be created.

Resolution:

With this release, an STS volume cannot be created unless it has a name.

Reference Number: Not available

Problem:

In RIS-IC–PACS integration with IDR in RIS-IC–driven mode, RA1000 failed to launch when an exam was selected in RIS-IC because extend properties were not found.

Resolution:

With this release, a code fix resolved the issue.

Reference Number: Not available

Problem:

In a Centricity PACS configuration without integrated reporting, an out-of-context situation occurred in Dictate mode when the user marked a report “Dictated,” and then cancelled instead of saving the exam images when prompted (per the Prompt To Save Image Before Closing preference).

Resolution:

With this release, in Dictate mode, the Cancel option is removed from the Prompt to Save dialog box to maintain context between exam and images.

Table 3-2: Resolved Issues in Centricity PACS 4.0 SP10 (Continued)

Issue Reference Number and Description

2085198-001 41

Page 42: C40_CRN_2085198-001sp10

Chapter 3 Release Content

Section 3: Upgrade Paths

Illustration 3-1 depicts upgrade paths to Centricity PACS 4.0 SP10. For more information, see the “Pre-Upgrade Planning” chapter in Centricity PACS Servers Installation and Upgrade Manual for this release of Centricity PACS.

Illustration 3-1:Upgrade Paths

2085198-001 42

Page 43: C40_CRN_2085198-001sp10

Chapter 4 Open Issues

This chapter includes:

Section 1: Report Palette Out of Synch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

Section 2: Browser Behavior When Using the Centricity Administration Tool. . . . . . . . . 43

Section 1: Report Palette Out of Synch

When a user has an exam open with a current and a prior exam, and clicks on the Synchronize Report with Exam in This Region button in the prior exam's viewport, occasionally the Report Palette will synch with the current exam's study information.

Section 2: Browser Behavior When Using the Centricity Administration Tool

2-1: Safari for Windows Issue

When users click OK to close the About window in the Centricity Administration (CA) tool, they are logged out of the tool.

Note: This issue occurs only when using the CA tool with Safari for Windows.

2-2: Viewing the Calendar in the CA Tool

When the calendar in the CA tool is displayed, the URL appears at the top of the calendar window in some browsers (e.g., Internet Explorer), whereas the URL area at the top of the calendar is blank in other browsers (e.g., Opera).

Illustration 4-1:Calendar with URL

2085198-001 43

Page 44: C40_CRN_2085198-001sp10

Chapter 4 Open Issues

Illustration 4-2:Calendar without URL

2-3: Security Prompt When Navigating the CA Tool

On the Users & Functions menu in the CA tool, when User Group is chosen from the drop-down menu on the User page, a security warning appears in some browsers (e.g., Firefox). If Continue (or Send, depending on the browser) is selected, the User Group page is displayed. If Cancel is selected, the User page is displayed even though the drop-down menu shows User Group.

Illustration 4-3:Security Warning

Illustration 4-4:Page Displayed When Security Warning Is Canceled

2085198-001 44

Page 45: C40_CRN_2085198-001sp10

Chapter 5 System Documentation Additions and Corrections

This chapter includes:

Section 1: RA1000 Workstation and Exam Manager Operator Manual . . . . . . . . . . . . . 45

Section 2: Workstation Installation and Service Manual . . . . . . . . . . . . . . . . . . . . . . . . . 46

Section 3: Servers Service Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

Section 4: System Administrator Online Help Manual . . . . . . . . . . . . . . . . . . . . . . . . . . 49

For a PDF copy of the Centricity PACS 4.0 SP10 release notes, visit the Common Documentation Library (CDL).

Section 1: RA1000 Workstation and Exam Manager Operator Manual

1-1: Filtering Images Not Supported for Display

In the Image View Area chapter, in the “Navigating in Exams” section, replace the note in “Navigating through Images” subsection with the following note:

Note: If the workstation cannot display a type of image (e.g., breast tomosynthesis images), the “Image Type Not Supported for Display” message appears. Your site administrator can set a Platinum property on the workstation to filter out images that are not supported for display. Filtering out images suppresses both the DICOM header information and the “Image Type Not Supported for Display” message.

1-2: Extends Online Help Not Available in Norwegian

In the Centricity Extend Applications chapter, add the following note at the end of the “Accessing the Extends Online Help” section:

Note: In Centricity PACS 4.0, the RA1000 workstation GUI, RA1000 Workstation and Exam Manager Operator Manual, and Workstation Quality Control Manual support the Norwegian language. The Extends Online Help, which Norwegian-language users access via the RA1000 Workstation and Exam Manager Operator Manual, is delivered in English.

2085198-001 45

Page 46: C40_CRN_2085198-001sp10

Chapter 5 System Documentation Additions and Corrections

Section 2: Workstation Installation and Service Manual

2-1: QC Tool Button Is Not Configurable

Add the following section to the Centricity Exam Manager Configuration chapter.

2-1-1: Launching RA600 from CEM

In RA1000, the Launch QC Tool button on the Patient Information tab of Centricity Exam Manager (CEM) launches RA600.

Note: The button cannot be configured to launch any other QC tool.

2-2: Synchronizing the Reporting System and RA1000 Worklist Selection (Browse Mode)

Add the following section to the Workstation Features Configuration chapter.

2-2-1: Synchronizing the Reporting System and RA1000 Worklist Selection (Browse Mode)

A Platinum property with its default setting (true) ensures that context is maintained between the reporting system and RA1000 worklist (Browse mode) when an exam is selected (highlighted):

com.ge.med.rumba.desktop.component.worklist.SyncVRwithWL=true

Where:

true (default) =

When Exam A and its report are open, if Exam B is selected in the worklist, the report for Exam A is closed.

Important If the Auto Save Report (Utilities > Reporting Integration Prefs) is checked, the report for Exam A is saved before closing. Otherwise, the report for Exam A is closed without saving changes.

If Exam A is selected again, if the Automatically Synchronize on PACS Context [Browse] preference (Utilities > Reporting Integration Prefs) is checked:

The saved report for Exam A is opened (see important note above)

OR

A new report for Exam A is opened, and if Prompt for Report Association is checked, the user is prompted to select verified studies for report association.

2085198-001 46

Page 47: C40_CRN_2085198-001sp10

Chapter 5 System Documentation Additions and Corrections

false = the reporting system window for Exam A is not closed, and a new reporting system window is opened when Exam B is selected in the worklist.

2-3: Platinum Extend Property Default in RIS-IC–PACS Integration

Add the section below to the Workstation Feature Configuration chapter.

2-3-1: RA1000 with RIS-IC Integration

In RIS-IC–PACS integration, the extend property default is a PACS-driven workflow:

com.ge.med.platinum.extend.extend2.idxWorklistDrivenMacro=false

Where:

false (default) = PACS-driven workflow

true = RIS-driven workflow

Set the value to true only for a RIS-driven workflow.

2-4: DDPs and Filtering Images Not Supported for Display

Add the note below at the end of the “Filtering Images Not Supported for Display” section in the Workstation Feature Configuration chapter.

Note: Hanging protocols (DDP) may require modification if they account for display of the “Image Not Supported for Display” message.

Section 3: Servers Service Manual

3-1: Setting ENM Configuration for HL Timeout

In Chapter 5, Configuring Event Notification Manager, in Section 5, “Configuring ENM for HL7 Synchronization from PACS to EA,” revise Section 5-2, “IMS Database Settings for HL7,” as indicated below.

2085198-001 47

Page 48: C40_CRN_2085198-001sp10

Chapter 5 System Documentation Additions and Corrections

In Step 8, revise the last row in Table 5-14, “IMS database table client_config”:

In Step 10d, “Add a Timeout record,” revise the last sentence:

The pvalue should be between 120 and 1200.

In Step 12, revise the last row in Table 5-16, “IMS Database Table client_config”:

In Table 5-16, “IMS database table client_config,” revise the last row:

client_id app_name pname pvalue pindex pdesc

HL ENM Timeout 120–1200 1 Timeout interval in seconds

Important: For a production site, set the HL timeout interval between 120 and 1200 seconds. Queue processing is adversely affected if the timeout interval is too low. The busier the site, the larger the value should be.

client_id app_name pname pvalue pindex pdesc

HL ENM Timeout 120–1200 1 Timeout interval in seconds

Important: For a production site, set the HL timeout interval between 120 and 1200 seconds. Queue processing is adversely affected if the timeout interval is too low. The busier the site, the larger the value should be.

client_id app_name pname pvalue pindex pdesc

<subscriber name>

ENM Timeout 120–1200 1 Timeout interval in seconds

Important: For a production site, set the HL timeout interval between 120 and 1200 seconds. Queue processing is adversely affected if the timeout interval is too low. The busier the site, the larger the value should be.

2085198-001 48

Page 49: C40_CRN_2085198-001sp10

Chapter 5 System Documentation Additions and Corrections

Section 4: System Administrator Online Help Manual

4-1: Enabling a User to Search for Another User

In Chapter 9, Users, Groups, and Functions, add the content below.

In Table 9-2, “IMS Function Privileges (for PACS only),” add the following row:

In Section 5-2, “Searching for a User,” add the following prerequisites after the section heading:

Prerequisites:

You must have the following privileges:

CATViewUsers&Functions

SearchUser

Privilege Description

SearchUser To search for a user

2085198-001 49

Page 50: C40_CRN_2085198-001sp10

2085198-001 50