Nokia Siemens Networks WCDMA RNC Rel. RN6.0, Site Documentation, Issue 01
Cable Lists for RNC2600
DN0938288
Issue 02Approval Date 2011-01-05
Confidential
Cable Lists for RNC2600
2 (41) © Nokia Siemens Networks
DN0938288Issue 1-0
The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation.
The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given “as is” and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2011. All rights reserved.
Contents
DN0938288 Issue 1-0
© Nokia Siemens Networks
3 (41)
Contents
1 About Cable lists for RNC2600 .............................................................5 1.1 Related documentation ............................................................................5
2 Identifying subracks, connectors and cables .....................................6 2.1 Numbering system of the subrack shelves and cable connectors ...........6 2.1.1 Locking pegs ............................................................................................8 2.2 Categories of cables.................................................................................8 2.2.1 Interconnection cables .............................................................................8 2.2.2 Site cables................................................................................................9 2.3 Identifying cables....................................................................................10 2.4 Cabling lists ............................................................................................12
3 Intracabinet cables for the RNAC cabinet..........................................13 3.1 RNAC power and fan tray control cables ...............................................13 3.2 RNAC bus cables...................................................................................14 3.3 RNAC LVDS cables ...............................................................................16 3.3.1 RNAC synchronization and LVDS cables ..............................................16 3.4 RNAC LAN cables..................................................................................18 3.5 RNAC alarm and synchronization cables...............................................20 3.6 RNAC protection switch cables ..............................................................22
4 Intracabinet cables for the RNBC cabinet..........................................24 4.1 RNBC power and fan tray control cables ...............................................24 4.2 RNBC HMS bus and timing bus cables..................................................25 4.3 RNBC protection switch cables ..............................................................26
5 Intercabinet cables from RNBC to RNAC...........................................29 5.1 Intercabinet HMS and timing cables.......................................................29 5.2 Intercabinet SWU LAN cables................................................................30 5.3 Intercabinet SFU LVDS lines..................................................................31
6 L3 Data Collector Cables .....................................................................36 6.1 L3 Data Collector Cables for RNAC cabinet ..........................................36 6.2 L3 Data Collector Cables for RNBC cabinet ..........................................37
7 Physical cable equipping positions and SW port connection coordinates.......................................................................38
Cable Lists for RNC2600
4 (41) © Nokia Siemens Networks
DN0938288Issue 1-0
Summary of changes
Change between issue 01 and 02
SCSI cables is removed. PCIe and Mini SAS cables is added.
Chapter 6 L3 Data Collector Cables is added.
HMS and timing bus cables is updated.
Routing of intercabinet LVDS cables is updated.
Cable Lists for RNC2600
DN0938288 Issue 1-0
© Nokia Siemens Networks
5 (41)
1 About Cable lists for RNC2600 This document provides a list of all the intercabinet and intracabinet cabling installed in the RNAC and RNBC cabinets in RNC2600.
1.1 Related documentation
Hardware configuration manual
For more detailed information on RNC cabinet mechanics, see Equipment Lists for RNC2600.
Engineering description
For basic information on, for example, RNC installation planning, see WCDMA RNC Engineering Description.
Installation manual
For detailed information on RNC hardware installation, see Installing the MGW and RNC.
Cable Lists for RNC2600
6 (41) © Nokia Siemens Networks
DN0938288Issue 1-0
2 Identifying subracks, connectors and cables
2.1 Numbering system of the subrack shelves and cable connectors
The positions of all connectors mentioned in this document are numbered by the co-ordinate system introduced here.
The equipment cabinets, subrack positions and cable connectors in the subracks have individual co-ordinate systems to facilitate the installation of subracks and the connection of cables.
The subrack positions of the cabinet are assigned with numbers from 1 to 4 from the top down. The subrack is identified by a sticker attached to its upper left corner.
Each subrack has 20 slots for plug-in units. The subracks are marked with the position numbers of the plug-in units. Seen from the front, each subrack includes 18 slots dimensioned for full-height plug-in units, numbered from 1 to 18 from left to right. The last two slots are for two half-height plug-in units located one on top of the other. The upper slot is numbered 19 and the lower one 38.
Cable Lists for RNC2600
DN0938288 Issue 1-0
© Nokia Siemens Networks
7 (41)
IPA2800 RNC / MGW cabinet,seen from the front
Slot position number
CA_020 OMU 0 1.0B 16.4X WDU 0-0 1.0B 17.3H CJA002 SCSI bus 0
CA_021 OMU 0 1.0B 16.5D WDU 0-0 1.0B 17.3O CJB002 SCSI bus 0
FU Connector FU Connector Type Use
Equip No. CABLE FROM CABLE TO
ConnectorType ACE
1.0B 16.4X
1 2 3F = FRONTB = BACK 4
DN05158647
Subrack in position 1 seen from the rear
A
C
E
G
J
L
N
P
R
T
V
X
Z
ZABCDEF
3
1
2
3
4
5
B
A
B
A
B
ConnectorType BDF
B
D
F
H
K
M
O
Q
S
U
W
Y
ZABCDEF
4
12345678910111213141516171819
2
Note
1
Figure 1 Notations used in the cabling lists
Cable Lists for RNC2600
8 (41) © Nokia Siemens Networks
DN0938288Issue 1-0
2.1.1 Locking pegs
Each connector is provided with locking devices (for example locking pegs or screws) that fasten the cable connector securely to the subrack.
The connector locking pegs are placed in the same positions in each subrack type, regardless of the subrack's position in a given cabinet. If the subrack includes supplementary locking pegs, they can be used as spare parts.
1
2
3
4
5
12345678910111213141516171819
XXX
X
XXXXX
XXX
XXXXXX
XXXXX
XXXXX
XXXXX
XX
X
X
X
XXXXX
XXXXX
XXXX
XXXXX
XXXXX
XXXXX
X XX
X XXXXX
X
XXX X
XX
XXX
XXX
XX
X X X X
XXXXX
XXXXX
XXXXX
XXXXXXXXXX
XXXXX
XXXXX
XX
XXXXXXXXXX
XXXXXXXXXX
XXXXXXXXXX
XXXXX
XXXXX
XX
X
XXXXX
XXX
XX
XXXXX
XX
Figure 2 Locking pegs’ positions (DN0953997)
2.2 Categories of cables
The cabling of an exchange consists of interconnection cables (intermediate cables) and site cables (outgoing cables) as described below.
2.2.1 Interconnection cables
The interconnection cables comprise all the cables inside each cabinet and between the cabinets which form a single exchange. The
Cable Lists for RNC2600
DN0938288 Issue 1-0
© Nokia Siemens Networks
9 (41)
interconnection cables are cut to length and equipped with connectors. They include:
Power distribution cables
ATM connection cables
Hardware Management Bus cables
Synchronization and timing cables
SCSI cables between storage units and their master units
LAN/Ethernet cables
Intracabinet cables
The interconnection cables between different subracks located in the same cabinet run from one subrack to another along the walls and cabling shelves of the cabinet. These cables are delivered completely installed in the cabinets.
Intercabinet cables
The interconnection cables running between different cabinets are led directly from one cabinet to another on cable shelves located behind the cabinets. These cables must be installed at the site. The interconnection cables are delivered as prefabricated cable sets.
2.2.2 Site cables
The site (outgoing) cables are all the cables that leave the exchange. They include:
Trunk circuit cables from the network interfaces
Power supply cables
Grounding cables
I/O cables
TCP/IP cables to the Network Management system
The site cables are connected directly to the plug-in units, or to the back interface units located at the rear of the cabinets. These cables must be installed at the site.
The site cables can be routed to the environment through the opening at the bottom (raised floor installations) or top plate (normal installation) of the EC216. These cables must be installed at the site.
Cable Lists for RNC2600
10 (41) © Nokia Siemens Networks
DN0938288Issue 1-0
All the cables entering the cabinet(s), except for the DC power feed cables, must have protective wires which are grounded to the frame of the exchange at the connectors in the cabling cabinets.
The site cables are not delivered in sets and vary in length depending on the delivery. They must be ordered separately and are designed for each delivery. They are not included in the standard documentation.
2.3 Identifying cables
The equipping reference is located on the Cable Identification Label
The first part of the equipping reference specifies the cable list where the cable is mentioned. The second part gives the sequence number within that list.
The equipping reference of the cables is based on the cabinet (type) name in which the cable is connected. There are two main groups:
1. Cables whose both ends are connected in the same cabinet (intracabinet cables).
The equipping information is expressed: [Cabinet type_sequence number].”CA_123”. There may be several identical cables of this type in a single Network Element, but only one within the same cabinet.
2. Cables which originate from one cabinet and end in another (intercabinet cables).
The equipping information is expressed: [Cabinet type, cabinet index_ sequence number].”CBn_123”. There may be only one of each individual cable of this type in a single Network Element.
All intercabinet cables connect from RNBC to RNAC.
The cabinet, where the cable starts in, determines the [cabinet type, cabinet index] part of the equipping reference.
Cable Lists for RNC2600
DN0938288 Issue 1-0
© Nokia Siemens Networks
11 (41)
DN99632985
b) Cable identification label
) A letter 'C' after the number indicates centimetres (cm) instead of decimetres (dm).
Example
a) Equipping number of cable, e.g.
Sequential number
ITEM NAME:CJA002 LOT ID: 3G9912
Alias name
Fixed length (dm)
Item identifier
Separators
Factory symbol
Year / Week
Interchangeability / version
C19179 .......... A01
CA-020
CA_020
a)
b)
CA_020
a)
Figure 2 Example of the marking system for the cables
Cable Lists for RNC2600
12 (41) © Nokia Siemens Networks
DN0938288Issue 1-0
2.4 Cabling lists
Cables are listed in tables. Each cable has its individual number. This number and the address of both ends of the cable are given. Both the name and coordinate of the functional unit, to which the end of the cable is connected, are given in a table. The columns of the table are used as follows:
Table 1 Explanation of cabling list columns
CABLE FROM CABLE TO
Equip. No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
Equip. No.
The equipping number is the individual number of the cable. Both ends of the cable bear a label with this number on it.
CABLE FROM (RNBC)
In case of intercabinet cabling, the text CABLE FROM indicates that the cable originates from the RNBC cabinet.
CABLE TO (RNAC)
In case of intercabinet cabling, the text CABLE TO indicates that the cable ends in the RNAC cabinet.
Cabinet Cabinet A (RNAC) or cabinet B (RNBC).
FU These columns give the name of the functional unit housed in the subrack where the ends of the cable connect to, for example MXU.
Position These columns give the coordinates of the connectors where the ends of the cable connect to.
Type This column gives the type (the first three letters) and length (the following two or three numbers) of the cable in decimetres (10 cm), or if marked with a C, in centimetres. For example, CHA010 is a cable of CHA type which is 100 cm long.
Use This column, when used, gives the type of signal carried by the cable, for example PDH line.
Note This column is for additional information.
Tip
The lengths of intracabinet cables in deliveries may be different than those given in this document.
Cable Lists for RNC2600
DN0938288 Issue 1-0
© Nokia Siemens Networks
13 (41)
3 Intracabinet cables for the RNAC cabinet
This chapter presents the intracabinet cabling for the RNAC cabinet in RNC2600.
Single cabinet figures show the RNAC cabinet. Two-cabinet figures show the RNAC and RNBC cabinets from left to right, unless otherwise indicated.
Tip
The lengths of intracabinet cables in deliveries may be different from those given in this document.
3.1 RNAC power and fan tray control cables
Table 2 RNAC CPD120-A power and fan tray control cables
CABLE FROM CABLE TO
Equip.
No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
Cable Lists for RNC2600
14 (41) © Nokia Siemens Networks
DN0938288Issue 1-0
CABLE FROM CABLE TO
Equip.
No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CA_001 A CPD120 UB2 0.10B P1 A PD30 0 1.0B 10_PP2 CVXB004 Power
CA_002 A CPD120 UB1 0.0B P1 A PD30 0 1.0B 10_PP1 CVXB004 Power
CA_003 A CPD120 UB2 0.10B P2 A PD30 1 2.0B 10_PP2 CVXB015 Power
CA_004 A CPD120 UB1 0.0B P2 A PD30 1 20B 10_PP1 CVXB015 Power
CA_005 A CPD120 UB2 0.10B P3 A PD30 2 3.0B 10_PP2 CVXB020 Power
CA_006 A CPD120 UB1 0.0B P3 A PD30 2 3.0B 10_PP1 CVXB020 Power
CA_007 A CPD120 UB2 0.10B P4 A PD30 3 4.0B 10_PP2 CVXB027 Power
CA_008 A CPD120 UB1 0.0B P4 A PD30 3 4.0B 10_PP1 CVXB027 Power
CA_010 A FTRA 1 1.0B A PD30 0 1.0B 10_P1 CXVB18C Control
CA_011 A FTRA 2 2.0B A PD30 1 2.0B 10_P1 CXVB18C Control
CA_012 A FTRA 3 3.0B A PD30 2 3.0B 10_P1 CXVB18C Control
CA_013 A FTRA 4 4.0B A PD30 3 4.0B 10_P1 CXVB18C Control
3.2 RNAC bus cables
Table 3 RNAC PCIe and Mini SAS cables
CABLE FROM CABLE TO
Equip.
No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CA_075 A OMU 0 1.0F 16.PCIe1 A WDU 0 (OMU) 1.0F 14.PCIe CQSFP25C PCIe
CA_076 A OMU 1 2.0F 16.PCIe1 A WDU 1 (OMU) 2.0F 14.PCIe CQSFP25C PCIe
CA_077 A WDU 0 (OMU) 1.0F 14.SAS A WDU 1 (OMU) 2.0F 14.SAS CMSAS011 SAS
Table 4 RNAC HMS and timing bus cables
CABLE FROM CABLE TO
Equip.
No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
Cable Lists for RNC2600
DN0938288 Issue 1-0
© Nokia Siemens Networks
15 (41)
CABLE FROM CABLE TO
Equip.
No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CA_040 A OMU 0 1.0B 16.3F A TBU 0 1.0B 19.2A CHZ006 HMS bus 0
CA_041 A OMU 1 2.0B 16.3F A TBU 0 2.0B 19.2A CHZ006 HMS bus 0
CA_042 A TBU 0 1.0B 19.2B A TBU 0 2.0B 19.2B CHZ011 HMS bus 0
CA_043 A TBU 0 2.0B 19.2C A TBU 0 3.0B 19.2A CHZ012 HMS bus 0
CA_044 A TBU 0 3.0B 19.2B A TBU 0 4.0B 19.2A CHZ012 HMS bus 0
CA_046 A TBU 0 4.0B 19.2C A TBU 0 4.0B 19.2D CHZ001 HMS bus 0 term.
CA_047 A OMU 0 1.0B 16.3G A TBU 1 1.0B 38.5A CHZ005 HMS bus 1
CA_048 A OMU 1 2.0B 16.3G A TBU 1 2.0B 38.5A CHZ005 HMS bus 1
CA_049 A TBU 1 1.0B 38.5B A TBU 1 2.0B 38.5B CHZ009 HMS bus 1
CA_050 A TBU 1 2.0B 38.5C A TBU 1 3.0B 38.5A CHZ010 HMS bus 1
CA_051 A TBU 1 3.0B 38.5B A TBU 1 4.0B 38.5A CHZ010 HMS bus 1
CA_053 A TBU 1 4.0B 38.5C A TBU 1 4.0B 38.5D CHZ001 HMS bus1 term.
CA_054 A TBU 0 1.0B 19.1Z A TBU 1 2.0B 38.4Z CHZS010 HMS bus
CA_063 A TBU 0 1.0B 19.2M A TBU 0 2.0B 19.2K CHZ011 TIMING bus 0
CA_064 A TBU 0 1.0B 19.2R A TBU 0 3.0B 19.2K CHZ016 TIMING bus 0
CA_065 A TBU 0 1.0B 19.2S A TBU 0 4.0B 19.2K CHZ020 TIMING bus 0
CA_057 A TBU 0 2.0B 19.2L A TBU 0 2.0B 19.2E CHZ001 TIMING bus 0 term.
CA_058 A TBU 0 3.0B 19.2L A TBU 0 3.0B 19.2E CHZ001 TIMING bus 0 term.
CA_066 A TBU 0 4.0B 19.2L A TBU 0 4.0B 19.2E CHZ001 TIMING bus 0 term.
CA_070 A TBU 1 2.0B 38.5R A TBU 1 1.0B 38.5K CHZ009 TIMING bus 1
CA_071 A TBU 1 2.0B 38.5S A TBU 1 3.0B 38.5K CHZ010 TIMING bus 1
CA_072 A TBU 1 2.0B 38.5M A TBU 1 4.0B 38.5K CHZ015 TIMING bus 1
CA_074 A TBU 0 1.0B 38.5L A TBU 0 1.0B 38.5E CHZ001 TIMING bus 1 term.
CA_078 A TBU 0 3.0B 38.5L A TBU 0 3.0B 38.5E CHZ001 TIMING bus 1 term.
CA_073 A TBU 1 4.0B 38.5L A TBU 1 4.0B 38.5E CHZ001 TIMING bus 1 term.
Cable Lists for RNC2600
16 (41) © Nokia Siemens Networks
DN0938288Issue 1-0
Table 5 RNAC default line timing cables
CABLE FROM CABLE TO
Equip. No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CA_060 A NPS1/NPS1P 2 3.0B 16.4V A TBU 0 1.0B 19.2G CHZ028 TIMING ref. 1 1) Default line timing
CA_061 A NPS1/NPS1P 3 4.0B 16.4V A TBU 0 1.0B 19.2H CHZ028 TIMING ref. 2 1) Default line timing
CA_062 A NPS1/NPS1P 4 3.0B 18.4V A TBU 0 1.0B 19.2J CHZ028 TIMING ref. 3 1) Default line timing
CA_067 A NPS1/NPS1P 2 3.0B 16.4X A TBU 1 2.0B 38.5G CHZ028 TIMING ref. 1 1) Default line timing
CA_068 A NPS1/NPS1P 3 4.0B 16.4X A TBU 1 2.0B 38.5H CHZ028 TIMING ref. 2 1) Default line timing
CA_069 A NPS1/NPS1P 4 3.0B 18.4X A TBU 1 2.0B 38.5J CHZ028 TIMING ref. 3 1) Default line timing
1) These cables must be installed last. They are bundled separately from other cables for easier modification.
3.3 RNAC LVDS cables
3.3.1 RNAC synchronization and LVDS cables
Table 6 RNAC SFU LVDS cables
CABLE FROM CABLE TO
Equip.
No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CA_200 A SFU 0 / BISFD
1.0B 1.B00 A MXU 0 / BISFB
1.0B 9.B00 CSB007 LVDS lines 3)
CA_201 A SFU 0 / BISFD
1.0B 1.B01 A MXU 1 / BISFB
1.0B 11.B00 CSB009 LVDS lines 3)
CA_202 A SFU 0 / BISFD
1.0B 1.B02 A MXU 2 / BISFB
2.0B 9.B00 CSB012 LVDS lines 3)
CA_203 A SFU 0 / BISFD
1.0B 1.B03 A MXU 3 / BISFB
2.0B 11.B00 CSB013 LVDS lines 3)
CA_204 A SFU 0 / BISFD
1.0B 1.B04 A MXU 4 / BISFB
3.0B 9.B00 CSB017 LVDS lines 3)
CA_205 A SFU 0 / BISFD
1.0B 1.B05 A MXU 5 / BISFB
3.0B 11.B00 CSB018 LVDS lines 3)
CA_206 A SFU 0 / BISFD
1.0B 1.B06 A MXU 6 / BISFB
4.0B 9.B00 CSB022 LVDS lines 3)
CA_207 A SFU 0 / BISFD
1.0B 1.B07 A MXU 7 / BISFB
4.0B 11.B00 CSB023 LVDS lines 3)
Cable Lists for RNC2600
DN0938288 Issue 1-0
© Nokia Siemens Networks
17 (41)
CABLE FROM CABLE TO
Equip.
No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CA_210 A SFU 0 / BISFA
1.0B 2.B16 A NPGE/NPGEP 0 /NP1S/NPS1P 0
BISFC
1.0B 17.B00 CSB009 LVDS lines 3)
CA_211 A SFU 0 / BISFA
1.0B 2.B17 A NPGE/NPGEP 1 /NP1S/NPS1P 1 BISFC
2.0B 17.B00 CSB014 LVDS lines 3)
CA_216 A SFU 0 / BISFA
1.0B 2.B18 A NPGE/NPGEP 2
BISFC
1.0B 18.B00 CSB009 LVDS lines 1) 3) Default:connected
CA_217 A SFU 0 / BISFA
1.0B 2.B19 A NPGE/NPGEP 3
BISFC
2.0B 18.B00 CSB014 LVDS lines 2) 3) Default:connected
CA_212 A SFU 0 / BISFA
1.0B 2.B20 A NPGE/NPGEP 4 /NP1S/NPS1P 2 BISFC
3.0B 15.B00 CSB019 LVDS lines 3)
CA_213 A SFU 0 / BISFA
1.0B 2.B21 A NPGE/NPGEP 5 /NP1S/NPS1P 3 BISFC
4.0B 15.B00 CSB025 LVDS lines 3)
CA_214 A SFU 0 / BISFA
1.0B 2.B22 A NPGE/NPGEP 6 /NP1S/NPS1P 4 /BISFC
3.0B 17.B00 CSB019 LVDS lines 3)
CA_215 A SFU 0 / BISFA
1.0B 2.B23 A NPGE/NPGEP 7 /NP1S/NPS1P 5 BISFC
4.0B 17.B00 CSB025 LVDS lines 3)
CA_220 A SFU 1 / BISFD
2.0B 1.B00 A MXU 0 / BISFB
1.0B 9.B02 CSB012 LVDS lines 3)
CA_221 A SFU 1 / BISFD
2.0B 1.B01 A MXU 1 / BISFB
1.0B 11.B02 CSB013 LVDS lines 3)
CA_222 A SFU 1 / BISFD
2.0B 1.B02 A MXU 2 / BISFB
2.0B 9.B02 CSB007 LVDS lines 3)
CA_223 A SFU 1 / BISFD
2.0B 1.B03 A MXU 3 / BISFB
2.0B 11.B02 CSB008 LVDS lines 3)
CA_224 A SFU 1 / BISFD
2.0B 1.B04 A MXU 4 / BISFB
3.0B 9.B02 CSB012 LVDS lines 3)
CA_225 A SFU 1 / BISFD
2.0B 1.B05 A MXU 5 / BISFB
3.0B 11.B02 CSB013 LVDS lines 3)
CA_226 A SFU 1 / BISFD
2.0B 1.B06 A MXU 6 / BISFB
4.0B 9.B02 CSB017 LVDS lines 3)
CA_227 A SFU 1 / BISFD
2.0B 1.B07 A MXU 7 / BISFB
4.0B 11.B02 CSB018 LVDS lines 3)
CA_230 A SFU 1 / BISFA
2.0B 2.B16 A NPGE/NPGEP 0 /NP1S/NPS1P 0 /BISFC
1.0B 17.B02 CSB014 LVDS lines 3)
CA_231 A SFU 1 / BISFA
2.0B 2.B17 A NPGE/NPGEP 1 /NP1S/NPS1P 1 BISFC
2.0B 17.B02 CSB008 LVDS lines 3)
CA_236 A SFU 1 / BISFA
2.0B 2.B18 A NPGE/NPGEP 2
BISFC
1.0B 18.B02 CSB015 LVDS lines 1) 3) Default:connected
CA_237 A SFU 1 / BISFA
2.0B 2.B19 A NPGE/NPGEP 3
BISFC
2.0B 18.B02 CSB008 LVDS lines 2) 3) Default:connected
CA_232 A SFU 1 / BISFA
2.0B 2.B20 A NPGE/NPGEP 4 /NP1S/NPS1P 2 BISFC
3.0B 15.B02 CSB014 LVDS lines 3)
Cable Lists for RNC2600
18 (41) © Nokia Siemens Networks
DN0938288Issue 1-0
CABLE FROM CABLE TO
Equip.
No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CA_233 A SFU 1 / BISFA
2.0B 2.B21 A NPGE/NPGEP 5 /NP1S/NPS1P 3 BISFC
4.0B 15.B02 CSB019 LVDS lines 3)
CA_234 A SFU 1 / BISFA
2.0B 2.B22 A NPGE/NPGEP 6 /NP1S/NPS1P 4 /BISFC
3.0B 17.B02 CSB014 LVDS lines 3)
CA_235 A SFU 1 / BISFA
2.0B 2.B23 A NPGE/NPGEP 7 /NP1S/NPS1P 5 BISFC
4.0B 17.B02 CSB019 LVDS lines 3)
1) Default: connected when NPGE/NPGEP 2 is in configuration.
Optional: removed when NPS1/NPS1P 0 is in configuration.
2) Default: connected when NPGE/NPGEP 3 is in configuration.
Optional: removed when NPS1/NPS1P 1 is in configuration.
3) Cables connected after panels BISFA, BISFB, BISFC and BISFD have been installed. Insert the back interface unit carefully, It is important to check that the locking screws are closed properly, and that the back interface unit is well in its place
Table 7 TSS3 synchronization cable
CABLE FROM CABLE TO
Equip. No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CA_305 A TSS3 1.0B 19.1X A TSS3 2.0B 38.4X CHE011 Sync
3.4 RNAC LAN cables
Table 8 RNAC SWU (ESA40) LAN cables with one SWU pair (SWU 0/1)
CABLE FROM CABLE TO
Equip.
No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CA_131 A SWU 0 1.0B 5.4E A OMU 1 2.0B 16.3B CHES013 LAN CA_130 A SWU 0 1.0B 5.4C A OMU 0 1.0B 16.3B CHES006 LAN
Cable Lists for RNC2600
DN0938288 Issue 1-0
© Nokia Siemens Networks
19 (41)
CABLE FROM CABLE TO
Equip.
No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CA_145 A SWU 0 1.0B 5.5D A NPGE/NPGEP 7 /
NPS1/NPS1P 5 4.0B 17.4E CIBS027 LAN
CA_144 A SWU 0 1.0B 5.5B A NPGE/NPGEP 6 /NPS1/NPS1P 4
3.0B 17.4E CIBS021 LAN
CA_143 A SWU 0 1.0B 5.4Z A NPGE/NPGEP 5 /NPS1/NPS1P 3
4.0B 15.4E CIBS027 LAN
CA_172 A SWU 0 1.0B 5.4X A NPGE/NPGEP 4 /NPS1/NPS1P 2
3.0B 15.4E CIBS021 LAN
CA_147 A SWU 0 1.0B 5.4V A NPGE/NPGEP 3 2.0B 18.4E CIBS013 LAN 2) Default: connected
CA_146 A SWU 0 1.0B 5.4T A NPGE/NPGEP 2 1.0B 18.4E CIBS007 LAN 1) Default: connected
CA_171 A SWU 0 1.0B 5.4R A NPGE/NPGEP 1 /NPS1/NPS1P 1
2.0B 17.4E CIBS013 LAN
CA_140 A SWU 0 1.0B 5.4P A NPGE/NPGEP 0 /NPS1/NPS1P 0
1.0B 17.4E CIBS007 LAN
CA_134 A SWU 1 2.0B 5.4J A SWU 0 1.0B 5.4J CHES017 LAN 3) Default:
Not connected
CA_139 A SWU 1 2.0B 5.4E A OMU 1 2.0B 16.3D CHES007 LAN CA_138 A SWU 1 2.0B 5.4C A OMU 0 1.0B 16.3D CHES014 LAN CA_155 A SWU 1 2.0B 5.5D A NPGE/NPGEP 7 /
NPS1/NPS1P 5 4.0B 17.4G CIBS021 LAN
CA_154 A SWU 1 2.0B 5.5B A NPGE/NPGEP 6 / NPS1/NPS1P 4
3.0B 17.4G CIBS021 LAN
CA_153 A SWU 1 2.0B 5.4Z A NPGE/NPGEP 5 / NPS1/NPS1P 3
4.0B 15.4G CIBS021 LAN
CA_152 A SWU 1 2.0B 5.4X A NPGE/NPGEP 4 /NPS1/NPS1P 2
3.0B 15.4G CIBS014 LAN
CA_149 A SWU 1 2.0B 5.4V A NPGE/NPGEP 3 2.0B 18.4G CIBS007 LAN 2) Default: connected
CA_148 A SWU 1 2.0B 5.4T A NPGE/NPGEP 2 1.0B 18.4G CIBS013 LAN 1) Default: connected
CA_151 A SWU 1 2.0B 5.4R A NPGE/NPGEP 1 / NPS1/NPS1P 1
2.0B 17.4G CIBS007 LAN
CA_150 A SWU 1 2.0B 5.4P A NPGE/NPGEP 0 /NPS1/NPS1P 0
1.0B 17.4G CIBS013 LAN
1) Default: Connected at factory. Connected when NPGE/NPGEP 2 is in configuration. Optional: removed when NPS1/NPS1P 0 is in configuration. 2) Default: Connected at factory. Connected when NPGE/NPGEP 3 is in configuration. Optional: removed when NPS1/NPS1P 1 is in configuration. 3) Default: Redundancy cable is not connected at the factory. Optional the cable is connected only when the Rabid Spanning Tree Protocol (RSTP) is enabled in the LAN sub network. Before connecting the cable, remember to activate STP/RSTP/MSTP according to the planned resiliency method
Cable Lists for RNC2600
20 (41) © Nokia Siemens Networks
DN0938288Issue 1-0
Table 9 Address setting modules
Position ID Name Use Note
1.0B 5.1S C108585 ADMOD01 SWU Cabinet address setting module
1.0B 5.1U C108585 ADMOD01 SWU Subrack address setting module
2.0B 5.1S C108585 ADMOD01 SWU Cabinet address setting module
2.0B 5.1U C108689 ADMOD02 SWU Subrack address setting module
3.5 RNAC alarm and synchronization cables
Table 10 RNAC alarm and synchronization cables to rear panels CPSY-A, CPSY-B and CPAL-A
CABLE FROM CABLE TO
Equip.
No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CA_015 A CAIND 0.0B 1 A EHU 3.0B 5.4E CID030 ALARM
CA_300 A CPAL-A 2.0B 1.A A EHU 3.0B 5.4G CJA016 Alarm
CA_301 A CPAL-A 2.0B 1.G A EHU 3.0B 5.4P CHQ016 Alarm
CA_302 A CPAL-A 2.0B 1.P A EHU 3.0B 5.4X CHM016 Alarm
1.0B 1.C 1)Default
1.0B 1.G 2)Optional
1.0B 1.L 3)Optional
CA_303 A CPSY-A
1.0B 1.P
A TSS3 1.0B 19.1V CHE010 Sync
4)Optional
1.10B 1.A 1)Default
1.10B 1.E 2)Optional
1.10B 1.J 3)Optional
CA_304 A CPSY-B
1.10B 1.N
A TSS3 2.0B 38.4V CHE010 Sync
4)Optional
CA_298 A SWU 0 1.0B 5.5Y A CPSY-A 1.0B 1.1V CHE012 Ethernet
CA_299 A CPSY-A 1.0B 1.1R A CPSY-B 1.10B 1.1T CHE005 Sync
CA_297 A CPSY-A 1.0B 1.1T A CPSY-B 1.10B 1.1R CHE005 Sync
1) BNC IN, BNC OUT, Default 2) BNC IN, RJ 45 OUT, Optional 3) RJ 45 IN, BNC OUT, Optional 4) RJ 45 IN, RJ 45 OUT, Optional
Cable Lists for RNC2600
DN0938288 Issue 1-0
© Nokia Siemens Networks
21 (41)
1918 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
38
1918 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
38
1918 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
38
1918 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
38
CPSY-A
CPAL-A
CPSY-B
DN05160803
Figure 3 CPSY-A, CPSY-B and CPAL-A panel positions in RNAC
Cable Lists for RNC2600
22 (41) © Nokia Siemens Networks
DN0938288Issue 1-0
3.6 RNAC protection switch cables
Table 11 MSP1+1, PIU_OK, PAIR_OK and switchover cables for RNAC
CABLE FROM CABLE TO
Equip.
No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CA_370 A NPS1P 0 1.0B 18.4T A NPS1P 1 2.0B 18.4T CIBS010 MSP1+1 Protection Switch
1) Default: not connected
CA_375 A NPS1P 0 1.0B 18.4R A NPS1P 1 2.0B 18.4R CIBS010 LVDS lines Protection Switch
1) Default: not connected
CA_374 A NPS1P 0 1.0B 18.4P A NPS1P 1 2.0B 18.4P CIBS010 LVDS lines Protection Switch
1) Default: not connected
CA_165 A NPGEP 2 1.0B 18.4L A NPGEP 3 2.0B 18.4L CHZS010 Switchover
NPS1P 0 NPS1P 1 MSP1+1 Protection Switch
CA_373 A
NPGEP 2
1.0B 18.4J A
NPGEP 3
2.0B 18.4J CIBS010
PIU_OK/ PAIR_OK
CA_372 A NPS1P 0 1.0B 18.4G A NPS1P 1 2.0B 18.4G CIBS010 MSP1+1 Protection Switch
1) Default: not connected
CA_371 A NPS1P 0 1.0B 18.4E A NPS1P 1 2.0B 18.4E CIBS010 MSP1+1 Protection Switch
1) Default: not connected
CA_163 A NPGEP 0 /
NPS1P 0
1.0B 17.4L A NPGEP 1 /
NPS1P 1
2.0B 17.4L CHZS010 Switchover
CA_164 A NPGEP 0 /
NPS1P 0
1.0B 17.4K A NPGEP 1 /
NPS1P 1
2.0B 17.4K CHZS010 PIU_OK/ PAIR_OK
CA_358 A NPS1P 2 3.0B 16.4T A NPS1P 3 4.0B 16.4T CIBS010 MSP1+1 Protection Switch
CA_361 A NPS1P 2 3.0B 16.4R A NPS1P 3 4.0B 16.4R CIBS010 LVDS lines Protection Switch
CA_360 A NPS1P 2 3.0B 16.4P A NPS1P 3 4.0B 16.4P CIBS010 LVDS lines Protection Switch
CA_351 A NPS1P 2 3.0B 16.4J A NPS1P 3 4.0B 16.4J CIBS010 MSP1+1 Protection Switch
CA_359 A NPS1P 2 3.0B 16.4G A NPS1P 3 4.0B 16.4G CIBS010 MSP1+1 Protection Switch
CA_350 A NPS1P 2 3.0B 16.4E A NPS1P 3 4.0B 16.4E CIBS010 MSP1+1 Protection Switch
CA_161 A NPGEP 4 /
NPS1P 2
3.0B 15.4L A NPGEP 5 /
NPS1P 3
4.0B 15.4L CHZS010 Switchover
Cable Lists for RNC2600
DN0938288 Issue 1-0
© Nokia Siemens Networks
23 (41)
CABLE FROM CABLE TO
Equip.
No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CA_162 A NPGEP 4 /
NPS1P 2
3.0B 15.4K A NPGEP 5 /
NPS1P 3
4.0B 15.4K CHZS010 PIU_OK/ PAIR_OK
CA_354 A NPS1P 4 3.0B 18.4T A NPS1P 5 4.0B 18.4T CIBS010 MSP1+1 Protection Switch
CA_357 A NPS1P 4 3.0B 18.4R A NPS1P 5 4.0B 18.4R CIBS010 LVDS lines Protection Switch
CA_356 A NPS1P 4 3.0B 18.4P A NPS1P 5 4.0B 18.4P CIBS010 LVDS lines Protection Switch
CA_353 A NPS1P 4 3.0B 18.4J A NPS1P 5 4.0B 18.4J CIBS010 MSP1+1 Protection Switch
CA_355 A NPS1P 4 3.0B 18.4G A NPS1P 5 4.0B 18.4G CIBS010 MSP1+1 Protection Switch
CA_352 A NPS1P 4 3.0B 18.4E A NPS1P 5 4.0B 18.4E CIBS010 MSP1+1 Protection Switch
CA_156 A NPGEP 6 /
NPS1P 4
3.0B 17.4L A NPGEP 7 /
NPS1P 5
4.0B 17.4L CHZS010 Switchover
CA_157 A NPGEP 6 /
NPS1P 4
3.0B 17.4K A NPGEP 7 /
NPS1P 5
4.0B 17.4K CHZS010 PIU_OK/ PAIR_OK
1) Default: Not connected at the factory. Cable is tied to the SRBI-C side plate near these equipping positions. Optional: Cables are connected these equipping positions when NPS1P 0 and NPS1P 1 pair are equipped.
Cable Lists for RNC2600
24 (41) © Nokia Siemens Networks
DN0938288Issue 1-0
4 Intracabinet cables for the RNBC cabinet
This chapter presents the intracabinet cabling for the RNBC cabinet in RNC2600.
Tip
The lengths of intracabinet cables in deliveries may be different than those given in this document.
4.1 RNBC power and fan tray control cables
Table 12 RNBC CPD120-A power cables and fan tray control cables
CABLE FROM CABLE TO
Equip.
No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CB_001 B CPD120 UB2 0.10B P1 B PD30 0 1.0B 10_PP2 CVXB004 Power
CB_002 B CPD120 UB1 0.0B P1 B PD30 0 1.0B 10_PP1 CVXB004 Power
CB_003 B CPD120 UB2 0.10B P2 B PD30 1 2.0B 10_PP2 CVXB015 Power
CB_004 B CPD120 UB1 0.0B P2 B PD30 1 2.0B 10_PP1 CVXB015 Power
CB_005 B CPD120 UB2 0.10B P3 B PD30 2 3.0B 10_PP2 CVXB020 Power
CB_006 B CPD120 UB1 0.0B P3 B PD30 2 3.0B 10_PP1 CVXB020 Power
CB_007 B CPD120 UB2 0.10B P4 B PD30 3 4.0B 10_PP2 CVXB027 Power
CB_008 B CPD120 UB1 0.0B P4 B PD30 3 4.0B 10_PP1 CVXB027 Power
CB_010 B FTRA 1 1.0B B PD30 0 1.0B 10_P1 CXVB18C Control
CB_011 B FTRA 2 2.0B B PD30 1 2.0B 10_P1 CXVB18C Control
Cable Lists for RNC2600
DN0938288 Issue 1-0
© Nokia Siemens Networks
25 (41)
CABLE FROM CABLE TO
Equip.
No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CB_012 B FTRA 3 3.0B B PD30 2 3.0B 10_P1 CXVB18C Control
CB_013 B FTRA 4 4.0B B PD30 3 4.0B 10_P1 CXVB18C Control
4.2 RNBC HMS bus and timing bus cables
Table 13 RNBC HMS and timing bus cables
CABLE FROM CABLE TO
Equip.
No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CB_020 B TBU 0 1.0B 19.2B B TBU 0 2.0B 19.2A CHZ011 HMS bus 0
CB_021 B TBU 0 2.0B 19.2B B TBU 0 3.0B 19.2A CHZ011 HMS bus 0
CB_022 B TBU 0 3.0B 19.2B B TBU 0 4.0B 19.2A CHZ011 HMS bus 0
CB_023 B TBU 0 4.0B 19.2C B TBU 0 4.0B 19.2D CHZ001 HMS bus 0 term
CB_024 B TBU 1 1.0B 38.5B B TBU 1 2.0B 38.5A CHZ009 HMS bus 1
CB_025 B TBU 1 2.0B 38.5B B TBU 1 3.0B 38.5A CHZ009 HMS bus 1
CB_026 B TBU 1 3.0B 38.5B B TBU 1 4.0B 38.5A CHZ009 HMS bus 1
CB_027 B TBU 1 4.0B 38.5C B TBU 1 4.0B 38.5D CHZ001 HMS bus 1 term
CB_030 B TBU 0 1.0B 19.2L B TBU 0 1.0B 19.2E CHZ001 TIMING bus 0
term.
CB_031 B TBU 0 2.0B 19.2L B TBU 0 2.0B 19.2E CHZ001 TIMING bus 0
term.
CB_032 B TBU 0 3.0B 19.2L B TBU 0 3.0B 19.2E CHZ001 TIMING bus 0
term.
CB_033 B TBU 0 4.0B 19.2L B TBU 0 4.0B 19.2E CHZ001 TIMING bus 0 term
CB_034 B TBU 1 1.0B 38.5L B TBU 1 1.0B 38.5E CHZ001 TIMING bus 1 term.
CB_035 B TBU 1 2.0B 38.5L B TBU 1 2.0B 38.5E CHZ001 TIMING bus 1 term.
Cable Lists for RNC2600
26 (41) © Nokia Siemens Networks
DN0938288Issue 1-0
CABLE FROM CABLE TO
Equip.
No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CB_036 B TBU 1 3.0B 38.5L B TBU 1 3.0B 38.5E CHZ001 TIMING bus 1 term.
CB_037 B TBU 1 4.0B 38.5L B TBU 1 4.0B 38.5E CHZ001 TIMING bus 1 term.
4.3 RNBC protection switch cables
Table 14 RNBC protection switch cables
CABLE FROM CABLE TO
Equip.
No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CB_354 B NPS1P 6 1.0B 16.4T B NPS1P 7 2.0B 16.4T CIBS013 MSP1+1 Protection Switch
CB_371 B NPS1P 6 1.0B 16.4E B NPS1P 7 2.0B 16.4E CIBS013 LVDS lines Protection Switch
CB_370 B NPS1P 6 1.0B 16.4J B NPS1P 7 2.0B 16.4J CIBS013 LVDS lines Protection Switch
CB_357 B NPS1P 6 1.0B 16.4R B NPS1P 7 2.0B 16.4R CIBS013 MSP1+1 Protection Switch
CB_356 B NPS1P 6 1.0B 16.4P B NPS1P 7 2.0B 16.4P CIBS013 MSP1+1 Protection Switch
CB_355 B NPS1P 6 1.0B 16.4G B NPS1P 7 2.0B 16.4G CIBS013 MSP1+1 Protection Switch
CB_358 B NPS1P 8 1.0B 18.4T B NPS1P 9 2.0B 18.4T CIBS013 MSP1+1 Protection Switch
CB_373 B NPS1P 8 1.0B 18.4E B NPS1P 9 2.0B 18.4E CIBS013 LVDS lines Protection Switch
CB_372 B NPS1P 8 1.0B 18.4J B NPS1P 9 2.0B 18.4J CIBS013 LVDS lines Protection Switch
Cable Lists for RNC2600
DN0938288 Issue 1-0
© Nokia Siemens Networks
27 (41)
CABLE FROM CABLE TO
Equip.
No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CB_361 B NPS1P 8 1.0B 18.4R B NPS1P 9 2.0B 18.4R CIBS013 MSP1+1 Protection Switch
CB_360 B NPS1P 8 1.0B 18.4P B NPS1P 9 2.0B 18.4P CIBS013 MSP1+1 Protection Switch
CB_359 B NPS1P 8 1.0B 18.4G B NPS1P 9 2.0B 18.4G CIBS013 MSP1+1 Protection Switch
CB_362 B NPS1P 10 3.0B 16.4T B NPS1P 11 4.0B 16.4T CIBS013 MSP1+1 Protection Switch
CB_375 B NPS1P 10 3.0B 16.4E B NPS1P 11 4.0B 16.4E CIBS013 LVDS lines Protection Switch
CB_374 B NPS1P 10 3.0B 16.4J B NPS1P 11 4.0B 16.4J CIBS013 LVDS lines Protection Switch
CB_365 B NPS1P 10 3.0B 16.4R B NPS1P 11 4.0B 16.4R CIBS013 MSP1+1 Protection Switch
CB_364 B NPS1P 10 3.0B 16.4P B NPS1P 11 4.0B 16.4P CIBS013 MSP1+1 Protection Switch
CB_363 B NPS1P 10 3.0B 16.4G B NPS1P 11 4.0B 16.4G CIBS013 MSP1+1 Protection Switch
CB_366 B NPS1P 12 3.0B 18.4T B NPS1P 13 4.0B 18.4T CIBS013 MSP1+1 Protection Switch
CB_377 B NPS1P 12 3.0B 18.4E B NPS1P 13 4.0B 18.4E CIBS013 LVDS lines Protection Switch
CB_376 B NPS1P 12 3.0B 18.4J B NPS1P 13 4.0B 18.4J CIBS013 LVDS lines Protection Switch
CB_369 B NPS1P 12 3.0B 18.4R B NPS1P 13 4.0B 18.4R CIBS013 MSP1+1 Protection Switch
CB_368 B NPS1P 12 3.0B 18.4P B NPS1P 13 4.0B 18.4P CIBS013 MSP1+1 Protection Switch
CB_367 B NPS1P 12 3.0B 18.4G B NPS1P 13 4.0B 18.4G CIBS013 MSP1+1 Protection Switch
Cable Lists for RNC2600
28 (41) © Nokia Siemens Networks
DN0938288Issue 1-0
CABLE FROM CABLE TO
Equip.
No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CB_380 B NPGEP 8 /
NPS1P 6
1.0B 15.4K B NPGEP 9 /
NPS1P 7
2.0B 15.4K CHZS015 PIU_OK
PAIR_OK
CB_381 B NPGEP 10 /
NPS1P 8
1.0B 17.4K B NPGEP 11 /
NPS1P 9
2.0B 17.4K CHZS015 PIU_OK
PAIR_OK
CB_382 B NPGEP 12 /
NPS1P 10
3.0B 15.4K B NPGEP 13 /
NPS1P 11
4.0B 15.4K CHZS015 PIU_OK
PAIR_OK
CB_383 B NPGEP 14 /
NPS1P 12
3.0B 17.4K B NPGEP 15 /
NPS1P 13
4.0B 17.4K CHZS015 PIU_OK
PAIR_OK
CB_390 B NPGEP 8 /
NPS1P 6
1.0B 15.4L B NPGEP 9 /
NPS1P 7
2.0B 15.4L CHZS015 Switchover
CB_391 B NPGEP 10 /
NPS1P 8
1.0B 17.4L B NPGEP 11 /
NPS1P 9
2.0B 17.4L CHZS015 Switchover
CB_392 B NPGEP 12 /
NPS1P 10
3.0B 15.4L B NPGEP 13 /
NPS1P 11
4.0B 15.4L CHZS015 Switchover
CB_393 B NPGEP 14 /
NPS1P 12
3.0B 17.4L B NPGEP 15 /
NPS1P 13
4.0B 17.4L CHZS015 Switchover
Cable Lists for RNC2600
DN0938288 Issue 1-0
© Nokia Siemens Networks
29 (41)
5 Intercabinet cables from RNBC to RNAC
This chapter presents cabling from the RNBC cabinet to the RNAC cabinet in RNC2600.
5.1 Intercabinet HMS and timing cables
Table 15 Intercabinet HMS and timing cables from RNBC to RNAC
CABLE FROM CABLE TO
Equip. No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CB0_050 B TBU 0 1.0B 19.2K A TBU 0 1.0B 19.2N CHZ016 TIMING bus 0
CB0_052 B TBU 0 2.0B 19.2K A TBU 0 1.0B 19.2O CHZ020 TIMING bus 0
CB0_054 B TBU 0 3.0B 19.2K A TBU 0 1.0B 19.2P CHZ024 TIMING bus 0
CB0_056 B TBU 0 4.0B 19.2K A TBU 0 1.0B 19.2Q CHZ028 TIMING bus 0
CB0_051 B TBU 1 1.0B 38.5K A TBU 1 2.0B 38.5N CHZ020 TIMING bus 1
CB0_053 B TBU 1 2.0B 38.5K A TBU 1 2.0B 38.5O CHZ016 TIMING bus 1
CB0_055 B TBU 1 3.0B 38.5K A TBU 1 2.0B 38.5P CHZ020 TIMING bus 1
CB0_057 B TBU 1 4.0B 38.5K A TBU 1 2.0B 38.5Q CHZ024 TIMING bus 1
A 3.0B 19.2D 1) HMS term.
CB0_040 B
TBU 0 1.0B 19.2A
A
TBU 0
1.0B 19.2C
CHZ020
HMS bus 0 2) HMS to B-cabinet
A 3.0B 38.5D 1) HMS term.
CB0_041 B
TBU 1 1.0B 38.5A
A
TBU 1
1.0B 38.5C
CHZ020
HMS bus 1 2) HMS to B-cabinet
Cable Lists for RNC2600
30 (41) © Nokia Siemens Networks
DN0938288Issue 1-0
CABLE FROM CABLE TO
Equip. No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
Cables CB0_040 and CB0_041 are not included in this cable set. Cables were delivered in RNAC-G 112045 cable set (RN5.0) or RNAC-H C112451 (RN6.0).
If RNBC is used, remove these cables from RNAC subrack 3 and move to new positions in RNBC subrack 1.
5.2 Intercabinet SWU LAN cables
Table 16 Intercabinet SWU LAN cables
CABLE FROM CABLE TO
Equip. No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CB0_107 B NPGE/NPGEP 15 /
NPS1/NPS1P 13 BISFC
4.0B 17.4E A SWU 0 1.0B 5.5U CIBS027 LAN 1)
CB0_106 B NPGE/NPGEP 14 /
NPS1/NPS1P 12 BISFC
3.0B 17.4E A SWU 0 1.0B 5.5S CIBS021 LAN 1)
CB0_105 B NPGE/NPGEP 13 /
NPS1/NPS1P 11 BISFC
4.0B 15.4E A SWU 0 1.0B 5.5Q CIBS027 LAN 1)
CB0_104 B NPGE/NPGEP 12 /
NPS1/NPS1P 10 BISFC
3.0B 15.4E A SWU 0 1.0B 5.5O CIBS021 LAN 1)
CB0_103 B NPGE/NPGEP 11 /
NPS1/NPS1P 9 BISFC
2.0B 17.4E A SWU 0 1.0B 5.5M CIBS018 LAN 1)
CB0_102 B NPGE/NPGEP 10 /
NPS1/NPS1P 8 BISFC
1.0B 17.4E A SWU 0 1.0B 5.5K CIBS014 LAN 1)
CB0_101 B NPGE/NPGEP 9 /
NPS1/NPS1P 7 BISFC
2.0B 15.4E A SWU 0 1.0B 5.5H CIBS018 LAN 1)
CB0_100 B NPGE/NPGEP 8 /
NPS1/NPS1P 6 BISFC
1.0B 15.4E A SWU 0 1.0B 5.5F CIBS014 LAN 1)
CB0_115 B NPGE/NPGEP 15 /
NPS1/NPS1P 13 BISFC
4.0B 17.4G A SWU 1 2.0B 5.5U CIBS021 LAN 1)
CB0_114 B NPGE/NPGEP 14 /
NPS1/NPS1P 12 BISFC
3.0B 17.4G A SWU 1 2.0B 5.5S CIBS018 LAN 1)
Cable Lists for RNC2600
DN0938288 Issue 1-0
© Nokia Siemens Networks
31 (41)
CABLE FROM CABLE TO
Equip. No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CB0_113 B NPGE/NPGEP 13 /
NPS1/NPS1P 11 BISFC
4.0B 15.4G A SWU 1 2.0B 5.5Q CIBS021 LAN 1)
CB0_112 B NPGE/NPGEP 12 /
NPS1/NPS1P 10
3.0B 15.4G A SWU 1 2.0B 5.5O CIBS018 LAN 1)
CB0_111 B NPGE/NPGEP 11 /
NPS1/NPS1P 9 BISFC
2.0B 17.4G A SWU 1 2.0B 5.5M CIBS014 LAN 1)
CB0_110 B NPGE/NPGEP 10 /
NPS1/NPS1P 8 BISFC
1.0B 17.4G A SWU 1 2.0B 5.5K CIBS018 LAN 1)
CB0_109 B NPGE/NPGEP 9 /
NPS1/NPS1P 7 BISFC
2.0B 15.4G A SWU 1 2.0B 5.5H CIBS014 LAN 1)
CB0_108 B NPGE/NPGEP 8 /
NPS1/NPS1P 6 BISFC
1.0B 15.4G A SWU 1 2.0B 5.5F CIBS018 LAN 1)
1) Cables are connected before the BISFC back interface unit has been installed.
5.3 Intercabinet SFU LVDS lines
Table 17 Intercabinet SFU LVDS cables
CABLE FROM CABLE TO
Equip. No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CB0_200 B MXU 8 /
BISFB
1.0B 9.B00 A SFU 0 /
BISFA
1.0B 2.B08 CSB018 LVDS lines 1)
CB0_201 B MXU 9 /
BISFB
1.0B 11.B00 A SFU 0 /
BISFA
1.0B 2.B09 CSB021 LVDS lines 1)
CB0_202 B MXU 10 /
BISFB
2.0B 9.B00 A SFU 0 /
BISFA
1.0B 2.B10 CSB022 LVDS lines 1)
CB0_203 B MXU 11 /
BISFB
2.0B 11.B00 A SFU 0 /
BISFA
1.0B 2.B11 CSB024 LVDS lines 1)
CB0_204 B MXU 12 /
BISFB
3.0B 9.B00 A SFU 0 /
BISFA
1.0B 2.B12 CSB028 LVDS lines 1)
CB0_205 B MXU13 /
BISFB
3.0B 11.B00 A SFU 0 /
BISFA
1.0B 2.B13 CSB030 LVDS lines 1)
CB0_206 B MXU 14 /
BISFB
4.0B 9.B00 A SFU 0 /
BISFA
1.0B 2.B14 CSB032 LVDS lines 1)
Cable Lists for RNC2600
32 (41) © Nokia Siemens Networks
DN0938288Issue 1-0
CABLE FROM CABLE TO
Equip. No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CB0_207 B MXU 15 /
BISFB
4.0B 11.B00 A SFU 0 /
BISFA
1.0B 2.B15 CSB032 LVDS lines 1)
CB0_208 B NPGE/NPGEP 8 /
NPS1/NPS1P 6
BISFC
1.0B 15.B00 A SFU 0 /
BISFA
1.0B 2.B24 CSB019 LVDS lines 1)
CB0_209 B NPGE/NPGEP 9 /
NPS1/NPS1P 7
BISFC
2.0B 15.B00 A SFU 0 /
BISFA
1.0B 2.B25 CSB025 LVDS lines 1)
CB0_210 B NPGE/NPGEP 10 /
NPS1/NPS1P 8
BISFC
1.0B 17.B00 A SFU 0 /
BISFA
1.0B 2.B26 CSB019 LVDS lines 1)
CB0_211 B NPGE/NPGEP 11 /
NPS1/NPS1P 9
BISFC
2.0B 17.B00 A SFU 0 /
BISFA
1.0B 2.B27 CSB025 LVDS lines 1)
CB0_212 B NPGE/NPGEP 12 /
NPS1/NPS1P 10
BISFC
3.0B 15.B00 A SFU 0 /
BISFA
1.0B 2.B28 CSB031 LVDS lines 1)
CB0_213 B NPGE/NPGEP 13 /
NPS1/NPS1P 11
BISFC
4.0B 15.B00 A SFU 0 /
BISFA
1.0B 2.B29 CSB034 LVDS lines 1)
CB0_214 B NPGE/NPGEP 14 /
NPS1/NPS1P 12
BISFC
3.0B 17.B00 A SFU 0 /
BISFA
1.0B 2.B30 CSB031 LVDS lines 1)
CB0_215 B NPGE/NPGEP 15 /
NPS1/NPS1P 13
BISFC
4.0B 17.B00 A SFU 0 /
BISFA
1.0B 2.B31 CSB034 LVDS lines 1)
CB0_216 B MXU 8 /
BISFB
1.0B 9.B02 A SFU 1 /
BISFA
2.0B 2.B08 CSB022 LVDS lines 1)
CB0_217 B MXU 9 /
BISFB
1.0B 11.B02 A SFU 1 /
BISFA
2.0B 2.B09 CSB024 LVDS lines 1)
CB0_218 B MXU 10 /
BISFB
2.0B 9.B02 A SFU 1 /
BISFA
2.0B 2.B10 CSB018 LVDS lines 1)
CB0_219 B MXU 11 /
BISFB
2.0B 11.B02 A SFU 1 /
BISFA
2.0B 2.B11 CSB021 LVDS lines 1)
CB0_220 B MXU 12 /
BISFB
3.0B 9.B02 A SFU 1 /
BISFA
2.0B 2.B12 CSB022 LVDS lines 1)
CB0_221 B MXU 13 /
BISFB
3.0B 11.B02 A SFU 1 /
BISFA
2.0B 2.B13 CSB024 LVDS lines 1)
CB0_222 B MXU 14 /
BISFB
4.0B 9.B02 A SFU 1 /
BISFA
2.0B 2.B14 CSB028 LVDS lines 1)
CB0_223 B MXU 15 /
BISFB
4.0B 11.B02 A SFU 1 /
BISFA
2.0B 2.B15 CSB030 LVDS lines 1)
CB0_224 B NPGE/NPGEP 8 /
NPS1/NPS1P 6
BISFC
1.0B 15.B02 A SFU 1 /
BISFA
2.0B 2.B24 CSB025 LVDS lines 1)
Cable Lists for RNC2600
DN0938288 Issue 1-0
© Nokia Siemens Networks
33 (41)
CABLE FROM CABLE TO
Equip. No
Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CB0_225 B NPGE/NPGEP 9 /
NPS1/NPS1P 7
BISFC
2.0B 15.B02 A SFU 1 /
BISFA
2.0B 2.B25 CSB019 LVDS lines 1)
CB0_226 B NPGE/NPGEP 10 /
NPS1/NPS1P 8
BISFC
1.0B 17.B02 A SFU 1 /
BISFA
2.0B 2.B26 CSB025 LVDS lines 1)
CB0_227 B NPGE/NPGEP 11 /
NPS1/NPS1P 9
BISFC
2.0B 17.B02 A SFU 1 /
BISFA
2.0B 2.B27 CSB019 LVDS lines 1)
CB0_228 B NPGE/NPGEP 12 /
NPS1/NPS1P 10
BISFC
3.0B 15.B02 A SFU 1 /
BISFA
2.0B 2.B28 CSB025 LVDS lines 1)
CB0_229 B NPGE/NPGEP 13 / NPS1/NPS1P 11 BISFC
4.0B 15.B02 A SFU 1 / BISFA
2.0B 2.B29 CSB031 LVDS lines 1)
CB0_230 B NPGE/NPGEP 14 /
NPS1/NPS1P 12
BISFC
3.0B 17.B02 A SFU 1 /
BISFA
2.0B 2.B30 CSB025 LVDS lines 1)
CB0_231 B NPGE/NPGEP 15 /
NPS1/NPS1P 13
BISFC
4.0B 17.B02 A SFU 1 /
BISFA
2.0B 2.B31 CSB031 LVDS lines 1)
1) Cables are connected after the BISFA, BISFB and BISFC back interface units have been installed. Insert the back interface unit carefully. Check that the locking screws are closed properly, and that the back interface unit is in its place.
Cable Lists for RNC2600
34 (41) © Nokia Siemens Networks
DN0938288Issue 1-0
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
38
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
38
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
38
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
38
RNACRNBC
Cable Lists for RNC2600
DN0938288 Issue 1-0
© Nokia Siemens Networks
35 (41)
Figure 4 Routing of intercabinet LVDS cables CB0_001 – CB0_032
Cable Lists for RNC2600
36 (41) © Nokia Siemens Networks
DN0938288Issue 1-0
6 L3 Data Collector Cables
This chapter presents L3 data collector in RNAC and RNBC.
6.1 L3 Data Collector Cables for RNAC cabinet
Table 18 L3 Data Collector Cables for RNAC cabinet
CABLE FROM CABLE TO
Equip.
No Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CA_250 A ICSU 0 1.0B 03.3B A CPLAN-A Port 4 CHUS014 LAN EL0
CA_251 A RSMU 0 1.0B 04.3B A CPLAN-A Port 2 CHUS014 LAN EL0
CA_252 A OMU 0 1.0B 16.3B A CPLAN-A Port 0 CHUS016 LAN EL1 Optional
CA_253 A ICSU 1 2.0B 03.3B A CPLAN-A Port 5 CHUS021 LAN EL0
CA_254 A RSMU 1 2.0B 04.3B A CPLAN-A Port 3 CHUS021 LAN EL0
CA_255 A ICSU 2 2.0B 06.3B A CPLAN-A Port 6 CHUS021 LAN EL0
CA_256 A OMU 1 2.0B 16.3B A CPLAN-A Port 1 CHUS020 LAN EL1 Optional
CA_257 A ICSU 3 3.0B 01.3B A CPLAN-A Port 7 CHUS024 LAN EL0
CA_258 A ICSU 4 3.0B 02.3B A CPLAN-A Port 8 CHUS024 LAN EL0
CA_259 A ICSU 5 3.0B 03.3B A CPLAN-A Port 9 CHUS024 LAN EL0
CA_260 A ICSU 6 3.0B 04.3B A CPLAN-A Port 10 CHUS024 LAN EL0
CA_261 A ICSU 7 3.0B 14.3B A CPLAN-A Port 11 CHUS025 LAN EL0
CA_262 A ICSU 8 4.0B 01.3B A CPLAN-A Port 12 CHUS025 LAN EL0
CA_263 A ICSU 9 4.0B 02.3B A CPLAN-A Port 13 CHUS026 LAN EL0
CA_264 A ICSU 10 4.0B 03.3B A CPLAN-A Port 14 CHUS026 LAN EL0
CA_265 A ICSU 11 4.0B 04.3B A CPLAN-A Port 15 CHUS026 LAN EL0
CA_266 A ICSU 12 4.0B 05.3B A CPLAN-A Port 16 CHUS026 LAN EL0
CA_267 A ICSU 13 4.0B 14.3B A CPLAN-A Port 17 CHUS027 LAN EL0
Cable Lists for RNC2600
DN0938288 Issue 1-0
© Nokia Siemens Networks
37 (41)
6.2 L3 Data Collector Cables for RNBC cabinet
Table 19 L3 Data Collector Cables for RNBC cabinet
CABLE FROM CABLE TO
Equip.
No Cab
inet
FU
Position
Cab
inet
FU
Position
Type
Use
Note
CB_250 B ICSU 14 1.0B 01.3B B CPLAN-A Port 0 CHUS016 LAN EL0
CB_251 B ICSU 15 1.0B 02.3B B CPLAN-A Port 1 CHUS016 LAN EL0
CB_252 B ICSU 16 1.0B 03.3B B CPLAN-A Port 2 CHUS016 LAN EL0
CB_253 B ICSU 17 1.0B 04.3B B CPLAN-A Port 3 CHUS016 LAN EL0
CB_254 B ICSU 18 1.0B 05.3B B CPLAN-A Port 4 CHUS016 LAN EL0
CB_255 B ICSU 19 1.0B 14.3B B CPLAN-A Port 5 CHUS018 LAN EL0
CB_256 B ICSU 20 2.0B 01.3B B CPLAN-A Port 6 CHUS018 LAN EL0
CB_257 B ICSU 21 2.0B 02.3B B CPLAN-A Port 7 CHUS018 LAN EL0
CB_258 B ICSU 22 2.0B 03.3B B CPLAN-A Port 8 CHUS018 LAN EL0
CB_259 B ICSU 23 2.0B 14.3B B CPLAN-A Port 9 CHUS018 LAN EL0
CB_260 B ICSU 24 2.0B 05.3B B CPLAN-A Port 10 CHUS018 LAN EL0
CB_261 B ICSU 25 2.0B 14.3B B CPLAN-A Port 11 CHUS020 LAN EL0
CB_262 B ICSU 26 3.0B 01.3B B CPLAN-A Port 12 CHUS021 LAN EL0
CB_263 B ICSU 27 3.0B 02.3B B CPLAN-A Port 13 CHUS021 LAN EL0
CB_264 B ICSU 28 3.0B 03.3B B CPLAN-A Port 14 CHUS021 LAN EL0
CB_265 B ICSU 29 3.0B 04.3B B CPLAN-A Port 15 CHUS021 LAN EL0
CB_266 B ICSU 30 3.0B 05.3B B CPLAN-A Port 16 CHUS021 LAN EL0
CB_267 B ICSU 31 3.0B 14.3B B CPLAN-A Port 17 CHUS024 LAN EL0
CB_268 B ICSU 32 4.0B 01.3B B CPLAN-A Port 18 CHUS026 LAN EL0
CB_269 B ICSU 33 4.0B 02.3B B CPLAN-A Port 19 CHUS026 LAN EL0
CB_270 B ICSU 34 4.0B 03.3B B CPLAN-A Port 20 CHUS026 LAN EL0
CB_271 B ICSU 35 4.0B 04.3B B CPLAN-A Port 21 CHUS026 LAN EL0
CB_272 B ICSU 36 4.0B 05.3B B CPLAN-A Port 22 CHUS026 LAN EL0
CB_273 B ICSU 37 4.0B 14.3B B CPLAN-A Port 23 CHUS028 LAN EL0
Cable Lists for RNC2600
38 (41) © Nokia Siemens Networks
DN0938288Issue 1-0
7 Physical cable equipping positions and SW port connection coordinates
This section shows the physical cable equipping positions in the subrack and the corresponding SW port connection coordinates, used in hardware configuration management.
The cable connection coordinates are needed when creating internal port connections between plug-in units' ports. For more information, see Creating connection descriptions in Hardware Configuration Management.
For example, for a cable installed in position 1.0B 1.4A, the port connection coordinate in hardware configuration management (WF commands) is B76. See also Figure 5 Notations used in table Physical cable equipping positions and corresponding SW port connection coordinates.
Cable Lists for RNC2600
DN0938288 Issue 1-0
© Nokia Siemens Networks
39 (41)
2A
C
E
G
J
L
N
P
R
T
V
X
Z
B
D
F
H
K
M
O
Q
S
U
W
Y
3
B1B2...
B25
B76
1
2
3
4
5
4A
...
...
B26
B51
B101
1 23
B76 4A
DN70206639
SW HW SW HW SW HW SW HW SW HWB1 1A B26 2A B51 3A B76 4A B101 5AB2 1B B27 2B B52 3B B77 4B B102 5B
Slot position number
Subrack seen from the rear
1
2
3
4
5
12345678910111213141516171819
1
Figure 5 Notations used in table Physical cable equipping positions and corresponding SW port connection coordinates
Cable Lists for RNC2600
40 (41) © Nokia Siemens Networks
DN0938288Issue 1-0
Table 18 Physical cable equipping positions and corresponding SW port connection coordinates
SW HW SW HW SW HW SW HW SW HW
B1 1A B26 2A B51 3A B76 4A B101 5A
B2 1B B27 2B B52 3B B77 4B B102 5B
B3 1C B28 2C B53 3C B78 4C B103 5C
B4 1D B29 2D B54 3D B79 4D B104 5D
B5 1E B30 2E B55 3E B80 4E B105 5E
B6 1F B31 2F B56 3F B81 4F B106 5F
B7 1G B32 2G B57 3G B82 4G B107 5G
B8 1H B33 2H B58 3H B83 4H B108 5H
B9 1J B34 2J B59 3J B84 4J B109 5J
B10 1K B35 2K B60 3K B85 4K B110 5K
B11 1L B36 2L B61 3L B86 4L B111 5L
B12 1M B37 2M B62 3M B87 4M B112 5M
B13 1N B38 2N B63 3N B88 4N B113 5N
B14 1O B39 2O B64 3O B89 4O B114 5O
B15 1P B40 2P B65 3P B90 4P B115 5P
B16 1Q B41 2Q B66 3Q B91 4Q B116 5Q
B17 1R B42 2R B67 3R B92 4R B117 5R
B18 1S B43 2S B68 3S B93 4S B118 5S
B19 1T B44 2T B69 3T B94 4T B119 5T
B20 1U B45 2U B70 3U B95 4U B120 5U
B21 1V B46 2V B71 3V B96 4V B121 5V
B22 1W B47 2W B72 3W B97 4W B122 5W
B23 1X B48 2X B73 3X B98 4X B123 5X
B24 1Y B49 2Y B74 3Y B99 4Y B124 5Y
B25 1Z
B50 2Z
B75 3Z
B100 4Z
B125 5Z
Cable Lists for RNC2600
DN0938288 Issue 1-0
© Nokia Siemens Networks
41 (41)