41
Nokia Siemens Networks WCDMA RNC Rel. RN6.0, Site Documentation, Issue 01 Cable Lists for RNC2600 DN0938288 Issue 02 Approval Date 2011-01-05 Confidential

Cable List Rnc2600

Embed Size (px)

Citation preview

Page 1: Cable List Rnc2600

Nokia Siemens Networks WCDMA RNC Rel. RN6.0, Site Documentation, Issue 01

Cable Lists for RNC2600

DN0938288

Issue 02Approval Date 2011-01-05

Confidential

Page 2: Cable List Rnc2600

Cable Lists for RNC2600

2 (41) © Nokia Siemens Networks

DN0938288Issue 1-0

The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation.

The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given “as is” and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document.

Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.

This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws.

The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG.

Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only.

Copyright © Nokia Siemens Networks 2011. All rights reserved.

Page 3: Cable List Rnc2600

Contents

DN0938288 Issue 1-0

© Nokia Siemens Networks

3 (41)

Contents

1 About Cable lists for RNC2600 .............................................................5 1.1 Related documentation ............................................................................5

2 Identifying subracks, connectors and cables .....................................6 2.1 Numbering system of the subrack shelves and cable connectors ...........6 2.1.1 Locking pegs ............................................................................................8 2.2 Categories of cables.................................................................................8 2.2.1 Interconnection cables .............................................................................8 2.2.2 Site cables................................................................................................9 2.3 Identifying cables....................................................................................10 2.4 Cabling lists ............................................................................................12

3 Intracabinet cables for the RNAC cabinet..........................................13 3.1 RNAC power and fan tray control cables ...............................................13 3.2 RNAC bus cables...................................................................................14 3.3 RNAC LVDS cables ...............................................................................16 3.3.1 RNAC synchronization and LVDS cables ..............................................16 3.4 RNAC LAN cables..................................................................................18 3.5 RNAC alarm and synchronization cables...............................................20 3.6 RNAC protection switch cables ..............................................................22

4 Intracabinet cables for the RNBC cabinet..........................................24 4.1 RNBC power and fan tray control cables ...............................................24 4.2 RNBC HMS bus and timing bus cables..................................................25 4.3 RNBC protection switch cables ..............................................................26

5 Intercabinet cables from RNBC to RNAC...........................................29 5.1 Intercabinet HMS and timing cables.......................................................29 5.2 Intercabinet SWU LAN cables................................................................30 5.3 Intercabinet SFU LVDS lines..................................................................31

6 L3 Data Collector Cables .....................................................................36 6.1 L3 Data Collector Cables for RNAC cabinet ..........................................36 6.2 L3 Data Collector Cables for RNBC cabinet ..........................................37

7 Physical cable equipping positions and SW port connection coordinates.......................................................................38

Page 4: Cable List Rnc2600

Cable Lists for RNC2600

4 (41) © Nokia Siemens Networks

DN0938288Issue 1-0

Summary of changes

Change between issue 01 and 02

SCSI cables is removed. PCIe and Mini SAS cables is added.

Chapter 6 L3 Data Collector Cables is added.

HMS and timing bus cables is updated.

Routing of intercabinet LVDS cables is updated.

Page 5: Cable List Rnc2600

Cable Lists for RNC2600

DN0938288 Issue 1-0

© Nokia Siemens Networks

5 (41)

1 About Cable lists for RNC2600 This document provides a list of all the intercabinet and intracabinet cabling installed in the RNAC and RNBC cabinets in RNC2600.

1.1 Related documentation

Hardware configuration manual

For more detailed information on RNC cabinet mechanics, see Equipment Lists for RNC2600.

Engineering description

For basic information on, for example, RNC installation planning, see WCDMA RNC Engineering Description.

Installation manual

For detailed information on RNC hardware installation, see Installing the MGW and RNC.

Page 6: Cable List Rnc2600

Cable Lists for RNC2600

6 (41) © Nokia Siemens Networks

DN0938288Issue 1-0

2 Identifying subracks, connectors and cables

2.1 Numbering system of the subrack shelves and cable connectors

The positions of all connectors mentioned in this document are numbered by the co-ordinate system introduced here.

The equipment cabinets, subrack positions and cable connectors in the subracks have individual co-ordinate systems to facilitate the installation of subracks and the connection of cables.

The subrack positions of the cabinet are assigned with numbers from 1 to 4 from the top down. The subrack is identified by a sticker attached to its upper left corner.

Each subrack has 20 slots for plug-in units. The subracks are marked with the position numbers of the plug-in units. Seen from the front, each subrack includes 18 slots dimensioned for full-height plug-in units, numbered from 1 to 18 from left to right. The last two slots are for two half-height plug-in units located one on top of the other. The upper slot is numbered 19 and the lower one 38.

Page 7: Cable List Rnc2600

Cable Lists for RNC2600

DN0938288 Issue 1-0

© Nokia Siemens Networks

7 (41)

IPA2800 RNC / MGW cabinet,seen from the front

Slot position number

CA_020 OMU 0 1.0B 16.4X WDU 0-0 1.0B 17.3H CJA002 SCSI bus 0

CA_021 OMU 0 1.0B 16.5D WDU 0-0 1.0B 17.3O CJB002 SCSI bus 0

FU Connector FU Connector Type Use

Equip No. CABLE FROM CABLE TO

ConnectorType ACE

1.0B 16.4X

1 2 3F = FRONTB = BACK 4

DN05158647

Subrack in position 1 seen from the rear

A

C

E

G

J

L

N

P

R

T

V

X

Z

ZABCDEF

3

1

2

3

4

5

B

A

B

A

B

ConnectorType BDF

B

D

F

H

K

M

O

Q

S

U

W

Y

ZABCDEF

4

12345678910111213141516171819

2

Note

1

Figure 1 Notations used in the cabling lists

Page 8: Cable List Rnc2600

Cable Lists for RNC2600

8 (41) © Nokia Siemens Networks

DN0938288Issue 1-0

2.1.1 Locking pegs

Each connector is provided with locking devices (for example locking pegs or screws) that fasten the cable connector securely to the subrack.

The connector locking pegs are placed in the same positions in each subrack type, regardless of the subrack's position in a given cabinet. If the subrack includes supplementary locking pegs, they can be used as spare parts.

1

2

3

4

5

12345678910111213141516171819

XXX

X

XXXXX

XXX

XXXXXX

XXXXX

XXXXX

XXXXX

XX

X

X

X

XXXXX

XXXXX

XXXX

XXXXX

XXXXX

XXXXX

X XX

X XXXXX

X

XXX X

XX

XXX

XXX

XX

X X X X

XXXXX

XXXXX

XXXXX

XXXXXXXXXX

XXXXX

XXXXX

XX

XXXXXXXXXX

XXXXXXXXXX

XXXXXXXXXX

XXXXX

XXXXX

XX

X

XXXXX

XXX

XX

XXXXX

XX

Figure 2 Locking pegs’ positions (DN0953997)

2.2 Categories of cables

The cabling of an exchange consists of interconnection cables (intermediate cables) and site cables (outgoing cables) as described below.

2.2.1 Interconnection cables

The interconnection cables comprise all the cables inside each cabinet and between the cabinets which form a single exchange. The

Page 9: Cable List Rnc2600

Cable Lists for RNC2600

DN0938288 Issue 1-0

© Nokia Siemens Networks

9 (41)

interconnection cables are cut to length and equipped with connectors. They include:

Power distribution cables

ATM connection cables

Hardware Management Bus cables

Synchronization and timing cables

SCSI cables between storage units and their master units

LAN/Ethernet cables

Intracabinet cables

The interconnection cables between different subracks located in the same cabinet run from one subrack to another along the walls and cabling shelves of the cabinet. These cables are delivered completely installed in the cabinets.

Intercabinet cables

The interconnection cables running between different cabinets are led directly from one cabinet to another on cable shelves located behind the cabinets. These cables must be installed at the site. The interconnection cables are delivered as prefabricated cable sets.

2.2.2 Site cables

The site (outgoing) cables are all the cables that leave the exchange. They include:

Trunk circuit cables from the network interfaces

Power supply cables

Grounding cables

I/O cables

TCP/IP cables to the Network Management system

The site cables are connected directly to the plug-in units, or to the back interface units located at the rear of the cabinets. These cables must be installed at the site.

The site cables can be routed to the environment through the opening at the bottom (raised floor installations) or top plate (normal installation) of the EC216. These cables must be installed at the site.

Page 10: Cable List Rnc2600

Cable Lists for RNC2600

10 (41) © Nokia Siemens Networks

DN0938288Issue 1-0

All the cables entering the cabinet(s), except for the DC power feed cables, must have protective wires which are grounded to the frame of the exchange at the connectors in the cabling cabinets.

The site cables are not delivered in sets and vary in length depending on the delivery. They must be ordered separately and are designed for each delivery. They are not included in the standard documentation.

2.3 Identifying cables

The equipping reference is located on the Cable Identification Label

The first part of the equipping reference specifies the cable list where the cable is mentioned. The second part gives the sequence number within that list.

The equipping reference of the cables is based on the cabinet (type) name in which the cable is connected. There are two main groups:

1. Cables whose both ends are connected in the same cabinet (intracabinet cables).

The equipping information is expressed: [Cabinet type_sequence number].”CA_123”. There may be several identical cables of this type in a single Network Element, but only one within the same cabinet.

2. Cables which originate from one cabinet and end in another (intercabinet cables).

The equipping information is expressed: [Cabinet type, cabinet index_ sequence number].”CBn_123”. There may be only one of each individual cable of this type in a single Network Element.

All intercabinet cables connect from RNBC to RNAC.

The cabinet, where the cable starts in, determines the [cabinet type, cabinet index] part of the equipping reference.

Page 11: Cable List Rnc2600

Cable Lists for RNC2600

DN0938288 Issue 1-0

© Nokia Siemens Networks

11 (41)

DN99632985

b) Cable identification label

) A letter 'C' after the number indicates centimetres (cm) instead of decimetres (dm).

Example

a) Equipping number of cable, e.g.

Sequential number

ITEM NAME:CJA002 LOT ID: 3G9912

Alias name

Fixed length (dm)

Item identifier

Separators

Factory symbol

Year / Week

Interchangeability / version

C19179 .......... A01

CA-020

CA_020

a)

b)

CA_020

a)

Figure 2 Example of the marking system for the cables

Page 12: Cable List Rnc2600

Cable Lists for RNC2600

12 (41) © Nokia Siemens Networks

DN0938288Issue 1-0

2.4 Cabling lists

Cables are listed in tables. Each cable has its individual number. This number and the address of both ends of the cable are given. Both the name and coordinate of the functional unit, to which the end of the cable is connected, are given in a table. The columns of the table are used as follows:

Table 1 Explanation of cabling list columns

CABLE FROM CABLE TO

Equip. No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

Equip. No.

The equipping number is the individual number of the cable. Both ends of the cable bear a label with this number on it.

CABLE FROM (RNBC)

In case of intercabinet cabling, the text CABLE FROM indicates that the cable originates from the RNBC cabinet.

CABLE TO (RNAC)

In case of intercabinet cabling, the text CABLE TO indicates that the cable ends in the RNAC cabinet.

Cabinet Cabinet A (RNAC) or cabinet B (RNBC).

FU These columns give the name of the functional unit housed in the subrack where the ends of the cable connect to, for example MXU.

Position These columns give the coordinates of the connectors where the ends of the cable connect to.

Type This column gives the type (the first three letters) and length (the following two or three numbers) of the cable in decimetres (10 cm), or if marked with a C, in centimetres. For example, CHA010 is a cable of CHA type which is 100 cm long.

Use This column, when used, gives the type of signal carried by the cable, for example PDH line.

Note This column is for additional information.

Tip

The lengths of intracabinet cables in deliveries may be different than those given in this document.

Page 13: Cable List Rnc2600

Cable Lists for RNC2600

DN0938288 Issue 1-0

© Nokia Siemens Networks

13 (41)

3 Intracabinet cables for the RNAC cabinet

This chapter presents the intracabinet cabling for the RNAC cabinet in RNC2600.

Single cabinet figures show the RNAC cabinet. Two-cabinet figures show the RNAC and RNBC cabinets from left to right, unless otherwise indicated.

Tip

The lengths of intracabinet cables in deliveries may be different from those given in this document.

3.1 RNAC power and fan tray control cables

Table 2 RNAC CPD120-A power and fan tray control cables

CABLE FROM CABLE TO

Equip.

No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

Page 14: Cable List Rnc2600

Cable Lists for RNC2600

14 (41) © Nokia Siemens Networks

DN0938288Issue 1-0

CABLE FROM CABLE TO

Equip.

No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CA_001 A CPD120 UB2 0.10B P1 A PD30 0 1.0B 10_PP2 CVXB004 Power

CA_002 A CPD120 UB1 0.0B P1 A PD30 0 1.0B 10_PP1 CVXB004 Power

CA_003 A CPD120 UB2 0.10B P2 A PD30 1 2.0B 10_PP2 CVXB015 Power

CA_004 A CPD120 UB1 0.0B P2 A PD30 1 20B 10_PP1 CVXB015 Power

CA_005 A CPD120 UB2 0.10B P3 A PD30 2 3.0B 10_PP2 CVXB020 Power

CA_006 A CPD120 UB1 0.0B P3 A PD30 2 3.0B 10_PP1 CVXB020 Power

CA_007 A CPD120 UB2 0.10B P4 A PD30 3 4.0B 10_PP2 CVXB027 Power

CA_008 A CPD120 UB1 0.0B P4 A PD30 3 4.0B 10_PP1 CVXB027 Power

CA_010 A FTRA 1 1.0B A PD30 0 1.0B 10_P1 CXVB18C Control

CA_011 A FTRA 2 2.0B A PD30 1 2.0B 10_P1 CXVB18C Control

CA_012 A FTRA 3 3.0B A PD30 2 3.0B 10_P1 CXVB18C Control

CA_013 A FTRA 4 4.0B A PD30 3 4.0B 10_P1 CXVB18C Control

3.2 RNAC bus cables

Table 3 RNAC PCIe and Mini SAS cables

CABLE FROM CABLE TO

Equip.

No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CA_075 A OMU 0 1.0F 16.PCIe1 A WDU 0 (OMU) 1.0F 14.PCIe CQSFP25C PCIe

CA_076 A OMU 1 2.0F 16.PCIe1 A WDU 1 (OMU) 2.0F 14.PCIe CQSFP25C PCIe

CA_077 A WDU 0 (OMU) 1.0F 14.SAS A WDU 1 (OMU) 2.0F 14.SAS CMSAS011 SAS

Table 4 RNAC HMS and timing bus cables

CABLE FROM CABLE TO

Equip.

No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

Page 15: Cable List Rnc2600

Cable Lists for RNC2600

DN0938288 Issue 1-0

© Nokia Siemens Networks

15 (41)

CABLE FROM CABLE TO

Equip.

No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CA_040 A OMU 0 1.0B 16.3F A TBU 0 1.0B 19.2A CHZ006 HMS bus 0

CA_041 A OMU 1 2.0B 16.3F A TBU 0 2.0B 19.2A CHZ006 HMS bus 0

CA_042 A TBU 0 1.0B 19.2B A TBU 0 2.0B 19.2B CHZ011 HMS bus 0

CA_043 A TBU 0 2.0B 19.2C A TBU 0 3.0B 19.2A CHZ012 HMS bus 0

CA_044 A TBU 0 3.0B 19.2B A TBU 0 4.0B 19.2A CHZ012 HMS bus 0

CA_046 A TBU 0 4.0B 19.2C A TBU 0 4.0B 19.2D CHZ001 HMS bus 0 term.

CA_047 A OMU 0 1.0B 16.3G A TBU 1 1.0B 38.5A CHZ005 HMS bus 1

CA_048 A OMU 1 2.0B 16.3G A TBU 1 2.0B 38.5A CHZ005 HMS bus 1

CA_049 A TBU 1 1.0B 38.5B A TBU 1 2.0B 38.5B CHZ009 HMS bus 1

CA_050 A TBU 1 2.0B 38.5C A TBU 1 3.0B 38.5A CHZ010 HMS bus 1

CA_051 A TBU 1 3.0B 38.5B A TBU 1 4.0B 38.5A CHZ010 HMS bus 1

CA_053 A TBU 1 4.0B 38.5C A TBU 1 4.0B 38.5D CHZ001 HMS bus1 term.

CA_054 A TBU 0 1.0B 19.1Z A TBU 1 2.0B 38.4Z CHZS010 HMS bus

CA_063 A TBU 0 1.0B 19.2M A TBU 0 2.0B 19.2K CHZ011 TIMING bus 0

CA_064 A TBU 0 1.0B 19.2R A TBU 0 3.0B 19.2K CHZ016 TIMING bus 0

CA_065 A TBU 0 1.0B 19.2S A TBU 0 4.0B 19.2K CHZ020 TIMING bus 0

CA_057 A TBU 0 2.0B 19.2L A TBU 0 2.0B 19.2E CHZ001 TIMING bus 0 term.

CA_058 A TBU 0 3.0B 19.2L A TBU 0 3.0B 19.2E CHZ001 TIMING bus 0 term.

CA_066 A TBU 0 4.0B 19.2L A TBU 0 4.0B 19.2E CHZ001 TIMING bus 0 term.

CA_070 A TBU 1 2.0B 38.5R A TBU 1 1.0B 38.5K CHZ009 TIMING bus 1

CA_071 A TBU 1 2.0B 38.5S A TBU 1 3.0B 38.5K CHZ010 TIMING bus 1

CA_072 A TBU 1 2.0B 38.5M A TBU 1 4.0B 38.5K CHZ015 TIMING bus 1

CA_074 A TBU 0 1.0B 38.5L A TBU 0 1.0B 38.5E CHZ001 TIMING bus 1 term.

CA_078 A TBU 0 3.0B 38.5L A TBU 0 3.0B 38.5E CHZ001 TIMING bus 1 term.

CA_073 A TBU 1 4.0B 38.5L A TBU 1 4.0B 38.5E CHZ001 TIMING bus 1 term.

Page 16: Cable List Rnc2600

Cable Lists for RNC2600

16 (41) © Nokia Siemens Networks

DN0938288Issue 1-0

Table 5 RNAC default line timing cables

CABLE FROM CABLE TO

Equip. No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CA_060 A NPS1/NPS1P 2 3.0B 16.4V A TBU 0 1.0B 19.2G CHZ028 TIMING ref. 1 1) Default line timing

CA_061 A NPS1/NPS1P 3 4.0B 16.4V A TBU 0 1.0B 19.2H CHZ028 TIMING ref. 2 1) Default line timing

CA_062 A NPS1/NPS1P 4 3.0B 18.4V A TBU 0 1.0B 19.2J CHZ028 TIMING ref. 3 1) Default line timing

CA_067 A NPS1/NPS1P 2 3.0B 16.4X A TBU 1 2.0B 38.5G CHZ028 TIMING ref. 1 1) Default line timing

CA_068 A NPS1/NPS1P 3 4.0B 16.4X A TBU 1 2.0B 38.5H CHZ028 TIMING ref. 2 1) Default line timing

CA_069 A NPS1/NPS1P 4 3.0B 18.4X A TBU 1 2.0B 38.5J CHZ028 TIMING ref. 3 1) Default line timing

1) These cables must be installed last. They are bundled separately from other cables for easier modification.

3.3 RNAC LVDS cables

3.3.1 RNAC synchronization and LVDS cables

Table 6 RNAC SFU LVDS cables

CABLE FROM CABLE TO

Equip.

No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CA_200 A SFU 0 / BISFD

1.0B 1.B00 A MXU 0 / BISFB

1.0B 9.B00 CSB007 LVDS lines 3)

CA_201 A SFU 0 / BISFD

1.0B 1.B01 A MXU 1 / BISFB

1.0B 11.B00 CSB009 LVDS lines 3)

CA_202 A SFU 0 / BISFD

1.0B 1.B02 A MXU 2 / BISFB

2.0B 9.B00 CSB012 LVDS lines 3)

CA_203 A SFU 0 / BISFD

1.0B 1.B03 A MXU 3 / BISFB

2.0B 11.B00 CSB013 LVDS lines 3)

CA_204 A SFU 0 / BISFD

1.0B 1.B04 A MXU 4 / BISFB

3.0B 9.B00 CSB017 LVDS lines 3)

CA_205 A SFU 0 / BISFD

1.0B 1.B05 A MXU 5 / BISFB

3.0B 11.B00 CSB018 LVDS lines 3)

CA_206 A SFU 0 / BISFD

1.0B 1.B06 A MXU 6 / BISFB

4.0B 9.B00 CSB022 LVDS lines 3)

CA_207 A SFU 0 / BISFD

1.0B 1.B07 A MXU 7 / BISFB

4.0B 11.B00 CSB023 LVDS lines 3)

Page 17: Cable List Rnc2600

Cable Lists for RNC2600

DN0938288 Issue 1-0

© Nokia Siemens Networks

17 (41)

CABLE FROM CABLE TO

Equip.

No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CA_210 A SFU 0 / BISFA

1.0B 2.B16 A NPGE/NPGEP 0 /NP1S/NPS1P 0

BISFC

1.0B 17.B00 CSB009 LVDS lines 3)

CA_211 A SFU 0 / BISFA

1.0B 2.B17 A NPGE/NPGEP 1 /NP1S/NPS1P 1 BISFC

2.0B 17.B00 CSB014 LVDS lines 3)

CA_216 A SFU 0 / BISFA

1.0B 2.B18 A NPGE/NPGEP 2

BISFC

1.0B 18.B00 CSB009 LVDS lines 1) 3) Default:connected

CA_217 A SFU 0 / BISFA

1.0B 2.B19 A NPGE/NPGEP 3

BISFC

2.0B 18.B00 CSB014 LVDS lines 2) 3) Default:connected

CA_212 A SFU 0 / BISFA

1.0B 2.B20 A NPGE/NPGEP 4 /NP1S/NPS1P 2 BISFC

3.0B 15.B00 CSB019 LVDS lines 3)

CA_213 A SFU 0 / BISFA

1.0B 2.B21 A NPGE/NPGEP 5 /NP1S/NPS1P 3 BISFC

4.0B 15.B00 CSB025 LVDS lines 3)

CA_214 A SFU 0 / BISFA

1.0B 2.B22 A NPGE/NPGEP 6 /NP1S/NPS1P 4 /BISFC

3.0B 17.B00 CSB019 LVDS lines 3)

CA_215 A SFU 0 / BISFA

1.0B 2.B23 A NPGE/NPGEP 7 /NP1S/NPS1P 5 BISFC

4.0B 17.B00 CSB025 LVDS lines 3)

CA_220 A SFU 1 / BISFD

2.0B 1.B00 A MXU 0 / BISFB

1.0B 9.B02 CSB012 LVDS lines 3)

CA_221 A SFU 1 / BISFD

2.0B 1.B01 A MXU 1 / BISFB

1.0B 11.B02 CSB013 LVDS lines 3)

CA_222 A SFU 1 / BISFD

2.0B 1.B02 A MXU 2 / BISFB

2.0B 9.B02 CSB007 LVDS lines 3)

CA_223 A SFU 1 / BISFD

2.0B 1.B03 A MXU 3 / BISFB

2.0B 11.B02 CSB008 LVDS lines 3)

CA_224 A SFU 1 / BISFD

2.0B 1.B04 A MXU 4 / BISFB

3.0B 9.B02 CSB012 LVDS lines 3)

CA_225 A SFU 1 / BISFD

2.0B 1.B05 A MXU 5 / BISFB

3.0B 11.B02 CSB013 LVDS lines 3)

CA_226 A SFU 1 / BISFD

2.0B 1.B06 A MXU 6 / BISFB

4.0B 9.B02 CSB017 LVDS lines 3)

CA_227 A SFU 1 / BISFD

2.0B 1.B07 A MXU 7 / BISFB

4.0B 11.B02 CSB018 LVDS lines 3)

CA_230 A SFU 1 / BISFA

2.0B 2.B16 A NPGE/NPGEP 0 /NP1S/NPS1P 0 /BISFC

1.0B 17.B02 CSB014 LVDS lines 3)

CA_231 A SFU 1 / BISFA

2.0B 2.B17 A NPGE/NPGEP 1 /NP1S/NPS1P 1 BISFC

2.0B 17.B02 CSB008 LVDS lines 3)

CA_236 A SFU 1 / BISFA

2.0B 2.B18 A NPGE/NPGEP 2

BISFC

1.0B 18.B02 CSB015 LVDS lines 1) 3) Default:connected

CA_237 A SFU 1 / BISFA

2.0B 2.B19 A NPGE/NPGEP 3

BISFC

2.0B 18.B02 CSB008 LVDS lines 2) 3) Default:connected

CA_232 A SFU 1 / BISFA

2.0B 2.B20 A NPGE/NPGEP 4 /NP1S/NPS1P 2 BISFC

3.0B 15.B02 CSB014 LVDS lines 3)

Page 18: Cable List Rnc2600

Cable Lists for RNC2600

18 (41) © Nokia Siemens Networks

DN0938288Issue 1-0

CABLE FROM CABLE TO

Equip.

No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CA_233 A SFU 1 / BISFA

2.0B 2.B21 A NPGE/NPGEP 5 /NP1S/NPS1P 3 BISFC

4.0B 15.B02 CSB019 LVDS lines 3)

CA_234 A SFU 1 / BISFA

2.0B 2.B22 A NPGE/NPGEP 6 /NP1S/NPS1P 4 /BISFC

3.0B 17.B02 CSB014 LVDS lines 3)

CA_235 A SFU 1 / BISFA

2.0B 2.B23 A NPGE/NPGEP 7 /NP1S/NPS1P 5 BISFC

4.0B 17.B02 CSB019 LVDS lines 3)

1) Default: connected when NPGE/NPGEP 2 is in configuration.

Optional: removed when NPS1/NPS1P 0 is in configuration.

2) Default: connected when NPGE/NPGEP 3 is in configuration.

Optional: removed when NPS1/NPS1P 1 is in configuration.

3) Cables connected after panels BISFA, BISFB, BISFC and BISFD have been installed. Insert the back interface unit carefully, It is important to check that the locking screws are closed properly, and that the back interface unit is well in its place

Table 7 TSS3 synchronization cable

CABLE FROM CABLE TO

Equip. No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CA_305 A TSS3 1.0B 19.1X A TSS3 2.0B 38.4X CHE011 Sync

3.4 RNAC LAN cables

Table 8 RNAC SWU (ESA40) LAN cables with one SWU pair (SWU 0/1)

CABLE FROM CABLE TO

Equip.

No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CA_131 A SWU 0 1.0B 5.4E A OMU 1 2.0B 16.3B CHES013 LAN CA_130 A SWU 0 1.0B 5.4C A OMU 0 1.0B 16.3B CHES006 LAN

Page 19: Cable List Rnc2600

Cable Lists for RNC2600

DN0938288 Issue 1-0

© Nokia Siemens Networks

19 (41)

CABLE FROM CABLE TO

Equip.

No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CA_145 A SWU 0 1.0B 5.5D A NPGE/NPGEP 7 /

NPS1/NPS1P 5 4.0B 17.4E CIBS027 LAN

CA_144 A SWU 0 1.0B 5.5B A NPGE/NPGEP 6 /NPS1/NPS1P 4

3.0B 17.4E CIBS021 LAN

CA_143 A SWU 0 1.0B 5.4Z A NPGE/NPGEP 5 /NPS1/NPS1P 3

4.0B 15.4E CIBS027 LAN

CA_172 A SWU 0 1.0B 5.4X A NPGE/NPGEP 4 /NPS1/NPS1P 2

3.0B 15.4E CIBS021 LAN

CA_147 A SWU 0 1.0B 5.4V A NPGE/NPGEP 3 2.0B 18.4E CIBS013 LAN 2) Default: connected

CA_146 A SWU 0 1.0B 5.4T A NPGE/NPGEP 2 1.0B 18.4E CIBS007 LAN 1) Default: connected

CA_171 A SWU 0 1.0B 5.4R A NPGE/NPGEP 1 /NPS1/NPS1P 1

2.0B 17.4E CIBS013 LAN

CA_140 A SWU 0 1.0B 5.4P A NPGE/NPGEP 0 /NPS1/NPS1P 0

1.0B 17.4E CIBS007 LAN

CA_134 A SWU 1 2.0B 5.4J A SWU 0 1.0B 5.4J CHES017 LAN 3) Default:

Not connected

CA_139 A SWU 1 2.0B 5.4E A OMU 1 2.0B 16.3D CHES007 LAN CA_138 A SWU 1 2.0B 5.4C A OMU 0 1.0B 16.3D CHES014 LAN CA_155 A SWU 1 2.0B 5.5D A NPGE/NPGEP 7 /

NPS1/NPS1P 5 4.0B 17.4G CIBS021 LAN

CA_154 A SWU 1 2.0B 5.5B A NPGE/NPGEP 6 / NPS1/NPS1P 4

3.0B 17.4G CIBS021 LAN

CA_153 A SWU 1 2.0B 5.4Z A NPGE/NPGEP 5 / NPS1/NPS1P 3

4.0B 15.4G CIBS021 LAN

CA_152 A SWU 1 2.0B 5.4X A NPGE/NPGEP 4 /NPS1/NPS1P 2

3.0B 15.4G CIBS014 LAN

CA_149 A SWU 1 2.0B 5.4V A NPGE/NPGEP 3 2.0B 18.4G CIBS007 LAN 2) Default: connected

CA_148 A SWU 1 2.0B 5.4T A NPGE/NPGEP 2 1.0B 18.4G CIBS013 LAN 1) Default: connected

CA_151 A SWU 1 2.0B 5.4R A NPGE/NPGEP 1 / NPS1/NPS1P 1

2.0B 17.4G CIBS007 LAN

CA_150 A SWU 1 2.0B 5.4P A NPGE/NPGEP 0 /NPS1/NPS1P 0

1.0B 17.4G CIBS013 LAN

1) Default: Connected at factory. Connected when NPGE/NPGEP 2 is in configuration. Optional: removed when NPS1/NPS1P 0 is in configuration. 2) Default: Connected at factory. Connected when NPGE/NPGEP 3 is in configuration. Optional: removed when NPS1/NPS1P 1 is in configuration. 3) Default: Redundancy cable is not connected at the factory. Optional the cable is connected only when the Rabid Spanning Tree Protocol (RSTP) is enabled in the LAN sub network. Before connecting the cable, remember to activate STP/RSTP/MSTP according to the planned resiliency method

Page 20: Cable List Rnc2600

Cable Lists for RNC2600

20 (41) © Nokia Siemens Networks

DN0938288Issue 1-0

Table 9 Address setting modules

Position ID Name Use Note

1.0B 5.1S C108585 ADMOD01 SWU Cabinet address setting module

1.0B 5.1U C108585 ADMOD01 SWU Subrack address setting module

2.0B 5.1S C108585 ADMOD01 SWU Cabinet address setting module

2.0B 5.1U C108689 ADMOD02 SWU Subrack address setting module

3.5 RNAC alarm and synchronization cables

Table 10 RNAC alarm and synchronization cables to rear panels CPSY-A, CPSY-B and CPAL-A

CABLE FROM CABLE TO

Equip.

No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CA_015 A CAIND 0.0B 1 A EHU 3.0B 5.4E CID030 ALARM

CA_300 A CPAL-A 2.0B 1.A A EHU 3.0B 5.4G CJA016 Alarm

CA_301 A CPAL-A 2.0B 1.G A EHU 3.0B 5.4P CHQ016 Alarm

CA_302 A CPAL-A 2.0B 1.P A EHU 3.0B 5.4X CHM016 Alarm

1.0B 1.C 1)Default

1.0B 1.G 2)Optional

1.0B 1.L 3)Optional

CA_303 A CPSY-A

1.0B 1.P

A TSS3 1.0B 19.1V CHE010 Sync

4)Optional

1.10B 1.A 1)Default

1.10B 1.E 2)Optional

1.10B 1.J 3)Optional

CA_304 A CPSY-B

1.10B 1.N

A TSS3 2.0B 38.4V CHE010 Sync

4)Optional

CA_298 A SWU 0 1.0B 5.5Y A CPSY-A 1.0B 1.1V CHE012 Ethernet

CA_299 A CPSY-A 1.0B 1.1R A CPSY-B 1.10B 1.1T CHE005 Sync

CA_297 A CPSY-A 1.0B 1.1T A CPSY-B 1.10B 1.1R CHE005 Sync

1) BNC IN, BNC OUT, Default 2) BNC IN, RJ 45 OUT, Optional 3) RJ 45 IN, BNC OUT, Optional 4) RJ 45 IN, RJ 45 OUT, Optional

Page 21: Cable List Rnc2600

Cable Lists for RNC2600

DN0938288 Issue 1-0

© Nokia Siemens Networks

21 (41)

1918 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

1918 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

1918 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

1918 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

CPSY-A

CPAL-A

CPSY-B

DN05160803

Figure 3 CPSY-A, CPSY-B and CPAL-A panel positions in RNAC

Page 22: Cable List Rnc2600

Cable Lists for RNC2600

22 (41) © Nokia Siemens Networks

DN0938288Issue 1-0

3.6 RNAC protection switch cables

Table 11 MSP1+1, PIU_OK, PAIR_OK and switchover cables for RNAC

CABLE FROM CABLE TO

Equip.

No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CA_370 A NPS1P 0 1.0B 18.4T A NPS1P 1 2.0B 18.4T CIBS010 MSP1+1 Protection Switch

1) Default: not connected

CA_375 A NPS1P 0 1.0B 18.4R A NPS1P 1 2.0B 18.4R CIBS010 LVDS lines Protection Switch

1) Default: not connected

CA_374 A NPS1P 0 1.0B 18.4P A NPS1P 1 2.0B 18.4P CIBS010 LVDS lines Protection Switch

1) Default: not connected

CA_165 A NPGEP 2 1.0B 18.4L A NPGEP 3 2.0B 18.4L CHZS010 Switchover

NPS1P 0 NPS1P 1 MSP1+1 Protection Switch

CA_373 A

NPGEP 2

1.0B 18.4J A

NPGEP 3

2.0B 18.4J CIBS010

PIU_OK/ PAIR_OK

CA_372 A NPS1P 0 1.0B 18.4G A NPS1P 1 2.0B 18.4G CIBS010 MSP1+1 Protection Switch

1) Default: not connected

CA_371 A NPS1P 0 1.0B 18.4E A NPS1P 1 2.0B 18.4E CIBS010 MSP1+1 Protection Switch

1) Default: not connected

CA_163 A NPGEP 0 /

NPS1P 0

1.0B 17.4L A NPGEP 1 /

NPS1P 1

2.0B 17.4L CHZS010 Switchover

CA_164 A NPGEP 0 /

NPS1P 0

1.0B 17.4K A NPGEP 1 /

NPS1P 1

2.0B 17.4K CHZS010 PIU_OK/ PAIR_OK

CA_358 A NPS1P 2 3.0B 16.4T A NPS1P 3 4.0B 16.4T CIBS010 MSP1+1 Protection Switch

CA_361 A NPS1P 2 3.0B 16.4R A NPS1P 3 4.0B 16.4R CIBS010 LVDS lines Protection Switch

CA_360 A NPS1P 2 3.0B 16.4P A NPS1P 3 4.0B 16.4P CIBS010 LVDS lines Protection Switch

CA_351 A NPS1P 2 3.0B 16.4J A NPS1P 3 4.0B 16.4J CIBS010 MSP1+1 Protection Switch

CA_359 A NPS1P 2 3.0B 16.4G A NPS1P 3 4.0B 16.4G CIBS010 MSP1+1 Protection Switch

CA_350 A NPS1P 2 3.0B 16.4E A NPS1P 3 4.0B 16.4E CIBS010 MSP1+1 Protection Switch

CA_161 A NPGEP 4 /

NPS1P 2

3.0B 15.4L A NPGEP 5 /

NPS1P 3

4.0B 15.4L CHZS010 Switchover

Page 23: Cable List Rnc2600

Cable Lists for RNC2600

DN0938288 Issue 1-0

© Nokia Siemens Networks

23 (41)

CABLE FROM CABLE TO

Equip.

No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CA_162 A NPGEP 4 /

NPS1P 2

3.0B 15.4K A NPGEP 5 /

NPS1P 3

4.0B 15.4K CHZS010 PIU_OK/ PAIR_OK

CA_354 A NPS1P 4 3.0B 18.4T A NPS1P 5 4.0B 18.4T CIBS010 MSP1+1 Protection Switch

CA_357 A NPS1P 4 3.0B 18.4R A NPS1P 5 4.0B 18.4R CIBS010 LVDS lines Protection Switch

CA_356 A NPS1P 4 3.0B 18.4P A NPS1P 5 4.0B 18.4P CIBS010 LVDS lines Protection Switch

CA_353 A NPS1P 4 3.0B 18.4J A NPS1P 5 4.0B 18.4J CIBS010 MSP1+1 Protection Switch

CA_355 A NPS1P 4 3.0B 18.4G A NPS1P 5 4.0B 18.4G CIBS010 MSP1+1 Protection Switch

CA_352 A NPS1P 4 3.0B 18.4E A NPS1P 5 4.0B 18.4E CIBS010 MSP1+1 Protection Switch

CA_156 A NPGEP 6 /

NPS1P 4

3.0B 17.4L A NPGEP 7 /

NPS1P 5

4.0B 17.4L CHZS010 Switchover

CA_157 A NPGEP 6 /

NPS1P 4

3.0B 17.4K A NPGEP 7 /

NPS1P 5

4.0B 17.4K CHZS010 PIU_OK/ PAIR_OK

1) Default: Not connected at the factory. Cable is tied to the SRBI-C side plate near these equipping positions. Optional: Cables are connected these equipping positions when NPS1P 0 and NPS1P 1 pair are equipped.

Page 24: Cable List Rnc2600

Cable Lists for RNC2600

24 (41) © Nokia Siemens Networks

DN0938288Issue 1-0

4 Intracabinet cables for the RNBC cabinet

This chapter presents the intracabinet cabling for the RNBC cabinet in RNC2600.

Tip

The lengths of intracabinet cables in deliveries may be different than those given in this document.

4.1 RNBC power and fan tray control cables

Table 12 RNBC CPD120-A power cables and fan tray control cables

CABLE FROM CABLE TO

Equip.

No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CB_001 B CPD120 UB2 0.10B P1 B PD30 0 1.0B 10_PP2 CVXB004 Power

CB_002 B CPD120 UB1 0.0B P1 B PD30 0 1.0B 10_PP1 CVXB004 Power

CB_003 B CPD120 UB2 0.10B P2 B PD30 1 2.0B 10_PP2 CVXB015 Power

CB_004 B CPD120 UB1 0.0B P2 B PD30 1 2.0B 10_PP1 CVXB015 Power

CB_005 B CPD120 UB2 0.10B P3 B PD30 2 3.0B 10_PP2 CVXB020 Power

CB_006 B CPD120 UB1 0.0B P3 B PD30 2 3.0B 10_PP1 CVXB020 Power

CB_007 B CPD120 UB2 0.10B P4 B PD30 3 4.0B 10_PP2 CVXB027 Power

CB_008 B CPD120 UB1 0.0B P4 B PD30 3 4.0B 10_PP1 CVXB027 Power

CB_010 B FTRA 1 1.0B B PD30 0 1.0B 10_P1 CXVB18C Control

CB_011 B FTRA 2 2.0B B PD30 1 2.0B 10_P1 CXVB18C Control

Page 25: Cable List Rnc2600

Cable Lists for RNC2600

DN0938288 Issue 1-0

© Nokia Siemens Networks

25 (41)

CABLE FROM CABLE TO

Equip.

No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CB_012 B FTRA 3 3.0B B PD30 2 3.0B 10_P1 CXVB18C Control

CB_013 B FTRA 4 4.0B B PD30 3 4.0B 10_P1 CXVB18C Control

4.2 RNBC HMS bus and timing bus cables

Table 13 RNBC HMS and timing bus cables

CABLE FROM CABLE TO

Equip.

No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CB_020 B TBU 0 1.0B 19.2B B TBU 0 2.0B 19.2A CHZ011 HMS bus 0

CB_021 B TBU 0 2.0B 19.2B B TBU 0 3.0B 19.2A CHZ011 HMS bus 0

CB_022 B TBU 0 3.0B 19.2B B TBU 0 4.0B 19.2A CHZ011 HMS bus 0

CB_023 B TBU 0 4.0B 19.2C B TBU 0 4.0B 19.2D CHZ001 HMS bus 0 term

CB_024 B TBU 1 1.0B 38.5B B TBU 1 2.0B 38.5A CHZ009 HMS bus 1

CB_025 B TBU 1 2.0B 38.5B B TBU 1 3.0B 38.5A CHZ009 HMS bus 1

CB_026 B TBU 1 3.0B 38.5B B TBU 1 4.0B 38.5A CHZ009 HMS bus 1

CB_027 B TBU 1 4.0B 38.5C B TBU 1 4.0B 38.5D CHZ001 HMS bus 1 term

CB_030 B TBU 0 1.0B 19.2L B TBU 0 1.0B 19.2E CHZ001 TIMING bus 0

term.

CB_031 B TBU 0 2.0B 19.2L B TBU 0 2.0B 19.2E CHZ001 TIMING bus 0

term.

CB_032 B TBU 0 3.0B 19.2L B TBU 0 3.0B 19.2E CHZ001 TIMING bus 0

term.

CB_033 B TBU 0 4.0B 19.2L B TBU 0 4.0B 19.2E CHZ001 TIMING bus 0 term

CB_034 B TBU 1 1.0B 38.5L B TBU 1 1.0B 38.5E CHZ001 TIMING bus 1 term.

CB_035 B TBU 1 2.0B 38.5L B TBU 1 2.0B 38.5E CHZ001 TIMING bus 1 term.

Page 26: Cable List Rnc2600

Cable Lists for RNC2600

26 (41) © Nokia Siemens Networks

DN0938288Issue 1-0

CABLE FROM CABLE TO

Equip.

No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CB_036 B TBU 1 3.0B 38.5L B TBU 1 3.0B 38.5E CHZ001 TIMING bus 1 term.

CB_037 B TBU 1 4.0B 38.5L B TBU 1 4.0B 38.5E CHZ001 TIMING bus 1 term.

4.3 RNBC protection switch cables

Table 14 RNBC protection switch cables

CABLE FROM CABLE TO

Equip.

No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CB_354 B NPS1P 6 1.0B 16.4T B NPS1P 7 2.0B 16.4T CIBS013 MSP1+1 Protection Switch

CB_371 B NPS1P 6 1.0B 16.4E B NPS1P 7 2.0B 16.4E CIBS013 LVDS lines Protection Switch

CB_370 B NPS1P 6 1.0B 16.4J B NPS1P 7 2.0B 16.4J CIBS013 LVDS lines Protection Switch

CB_357 B NPS1P 6 1.0B 16.4R B NPS1P 7 2.0B 16.4R CIBS013 MSP1+1 Protection Switch

CB_356 B NPS1P 6 1.0B 16.4P B NPS1P 7 2.0B 16.4P CIBS013 MSP1+1 Protection Switch

CB_355 B NPS1P 6 1.0B 16.4G B NPS1P 7 2.0B 16.4G CIBS013 MSP1+1 Protection Switch

CB_358 B NPS1P 8 1.0B 18.4T B NPS1P 9 2.0B 18.4T CIBS013 MSP1+1 Protection Switch

CB_373 B NPS1P 8 1.0B 18.4E B NPS1P 9 2.0B 18.4E CIBS013 LVDS lines Protection Switch

CB_372 B NPS1P 8 1.0B 18.4J B NPS1P 9 2.0B 18.4J CIBS013 LVDS lines Protection Switch

Page 27: Cable List Rnc2600

Cable Lists for RNC2600

DN0938288 Issue 1-0

© Nokia Siemens Networks

27 (41)

CABLE FROM CABLE TO

Equip.

No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CB_361 B NPS1P 8 1.0B 18.4R B NPS1P 9 2.0B 18.4R CIBS013 MSP1+1 Protection Switch

CB_360 B NPS1P 8 1.0B 18.4P B NPS1P 9 2.0B 18.4P CIBS013 MSP1+1 Protection Switch

CB_359 B NPS1P 8 1.0B 18.4G B NPS1P 9 2.0B 18.4G CIBS013 MSP1+1 Protection Switch

CB_362 B NPS1P 10 3.0B 16.4T B NPS1P 11 4.0B 16.4T CIBS013 MSP1+1 Protection Switch

CB_375 B NPS1P 10 3.0B 16.4E B NPS1P 11 4.0B 16.4E CIBS013 LVDS lines Protection Switch

CB_374 B NPS1P 10 3.0B 16.4J B NPS1P 11 4.0B 16.4J CIBS013 LVDS lines Protection Switch

CB_365 B NPS1P 10 3.0B 16.4R B NPS1P 11 4.0B 16.4R CIBS013 MSP1+1 Protection Switch

CB_364 B NPS1P 10 3.0B 16.4P B NPS1P 11 4.0B 16.4P CIBS013 MSP1+1 Protection Switch

CB_363 B NPS1P 10 3.0B 16.4G B NPS1P 11 4.0B 16.4G CIBS013 MSP1+1 Protection Switch

CB_366 B NPS1P 12 3.0B 18.4T B NPS1P 13 4.0B 18.4T CIBS013 MSP1+1 Protection Switch

CB_377 B NPS1P 12 3.0B 18.4E B NPS1P 13 4.0B 18.4E CIBS013 LVDS lines Protection Switch

CB_376 B NPS1P 12 3.0B 18.4J B NPS1P 13 4.0B 18.4J CIBS013 LVDS lines Protection Switch

CB_369 B NPS1P 12 3.0B 18.4R B NPS1P 13 4.0B 18.4R CIBS013 MSP1+1 Protection Switch

CB_368 B NPS1P 12 3.0B 18.4P B NPS1P 13 4.0B 18.4P CIBS013 MSP1+1 Protection Switch

CB_367 B NPS1P 12 3.0B 18.4G B NPS1P 13 4.0B 18.4G CIBS013 MSP1+1 Protection Switch

Page 28: Cable List Rnc2600

Cable Lists for RNC2600

28 (41) © Nokia Siemens Networks

DN0938288Issue 1-0

CABLE FROM CABLE TO

Equip.

No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CB_380 B NPGEP 8 /

NPS1P 6

1.0B 15.4K B NPGEP 9 /

NPS1P 7

2.0B 15.4K CHZS015 PIU_OK

PAIR_OK

CB_381 B NPGEP 10 /

NPS1P 8

1.0B 17.4K B NPGEP 11 /

NPS1P 9

2.0B 17.4K CHZS015 PIU_OK

PAIR_OK

CB_382 B NPGEP 12 /

NPS1P 10

3.0B 15.4K B NPGEP 13 /

NPS1P 11

4.0B 15.4K CHZS015 PIU_OK

PAIR_OK

CB_383 B NPGEP 14 /

NPS1P 12

3.0B 17.4K B NPGEP 15 /

NPS1P 13

4.0B 17.4K CHZS015 PIU_OK

PAIR_OK

CB_390 B NPGEP 8 /

NPS1P 6

1.0B 15.4L B NPGEP 9 /

NPS1P 7

2.0B 15.4L CHZS015 Switchover

CB_391 B NPGEP 10 /

NPS1P 8

1.0B 17.4L B NPGEP 11 /

NPS1P 9

2.0B 17.4L CHZS015 Switchover

CB_392 B NPGEP 12 /

NPS1P 10

3.0B 15.4L B NPGEP 13 /

NPS1P 11

4.0B 15.4L CHZS015 Switchover

CB_393 B NPGEP 14 /

NPS1P 12

3.0B 17.4L B NPGEP 15 /

NPS1P 13

4.0B 17.4L CHZS015 Switchover

Page 29: Cable List Rnc2600

Cable Lists for RNC2600

DN0938288 Issue 1-0

© Nokia Siemens Networks

29 (41)

5 Intercabinet cables from RNBC to RNAC

This chapter presents cabling from the RNBC cabinet to the RNAC cabinet in RNC2600.

5.1 Intercabinet HMS and timing cables

Table 15 Intercabinet HMS and timing cables from RNBC to RNAC

CABLE FROM CABLE TO

Equip. No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CB0_050 B TBU 0 1.0B 19.2K A TBU 0 1.0B 19.2N CHZ016 TIMING bus 0

CB0_052 B TBU 0 2.0B 19.2K A TBU 0 1.0B 19.2O CHZ020 TIMING bus 0

CB0_054 B TBU 0 3.0B 19.2K A TBU 0 1.0B 19.2P CHZ024 TIMING bus 0

CB0_056 B TBU 0 4.0B 19.2K A TBU 0 1.0B 19.2Q CHZ028 TIMING bus 0

CB0_051 B TBU 1 1.0B 38.5K A TBU 1 2.0B 38.5N CHZ020 TIMING bus 1

CB0_053 B TBU 1 2.0B 38.5K A TBU 1 2.0B 38.5O CHZ016 TIMING bus 1

CB0_055 B TBU 1 3.0B 38.5K A TBU 1 2.0B 38.5P CHZ020 TIMING bus 1

CB0_057 B TBU 1 4.0B 38.5K A TBU 1 2.0B 38.5Q CHZ024 TIMING bus 1

A 3.0B 19.2D 1) HMS term.

CB0_040 B

TBU 0 1.0B 19.2A

A

TBU 0

1.0B 19.2C

CHZ020

HMS bus 0 2) HMS to B-cabinet

A 3.0B 38.5D 1) HMS term.

CB0_041 B

TBU 1 1.0B 38.5A

A

TBU 1

1.0B 38.5C

CHZ020

HMS bus 1 2) HMS to B-cabinet

Page 30: Cable List Rnc2600

Cable Lists for RNC2600

30 (41) © Nokia Siemens Networks

DN0938288Issue 1-0

CABLE FROM CABLE TO

Equip. No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

Cables CB0_040 and CB0_041 are not included in this cable set. Cables were delivered in RNAC-G 112045 cable set (RN5.0) or RNAC-H C112451 (RN6.0).

If RNBC is used, remove these cables from RNAC subrack 3 and move to new positions in RNBC subrack 1.

5.2 Intercabinet SWU LAN cables

Table 16 Intercabinet SWU LAN cables

CABLE FROM CABLE TO

Equip. No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CB0_107 B NPGE/NPGEP 15 /

NPS1/NPS1P 13 BISFC

4.0B 17.4E A SWU 0 1.0B 5.5U CIBS027 LAN 1)

CB0_106 B NPGE/NPGEP 14 /

NPS1/NPS1P 12 BISFC

3.0B 17.4E A SWU 0 1.0B 5.5S CIBS021 LAN 1)

CB0_105 B NPGE/NPGEP 13 /

NPS1/NPS1P 11 BISFC

4.0B 15.4E A SWU 0 1.0B 5.5Q CIBS027 LAN 1)

CB0_104 B NPGE/NPGEP 12 /

NPS1/NPS1P 10 BISFC

3.0B 15.4E A SWU 0 1.0B 5.5O CIBS021 LAN 1)

CB0_103 B NPGE/NPGEP 11 /

NPS1/NPS1P 9 BISFC

2.0B 17.4E A SWU 0 1.0B 5.5M CIBS018 LAN 1)

CB0_102 B NPGE/NPGEP 10 /

NPS1/NPS1P 8 BISFC

1.0B 17.4E A SWU 0 1.0B 5.5K CIBS014 LAN 1)

CB0_101 B NPGE/NPGEP 9 /

NPS1/NPS1P 7 BISFC

2.0B 15.4E A SWU 0 1.0B 5.5H CIBS018 LAN 1)

CB0_100 B NPGE/NPGEP 8 /

NPS1/NPS1P 6 BISFC

1.0B 15.4E A SWU 0 1.0B 5.5F CIBS014 LAN 1)

CB0_115 B NPGE/NPGEP 15 /

NPS1/NPS1P 13 BISFC

4.0B 17.4G A SWU 1 2.0B 5.5U CIBS021 LAN 1)

CB0_114 B NPGE/NPGEP 14 /

NPS1/NPS1P 12 BISFC

3.0B 17.4G A SWU 1 2.0B 5.5S CIBS018 LAN 1)

Page 31: Cable List Rnc2600

Cable Lists for RNC2600

DN0938288 Issue 1-0

© Nokia Siemens Networks

31 (41)

CABLE FROM CABLE TO

Equip. No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CB0_113 B NPGE/NPGEP 13 /

NPS1/NPS1P 11 BISFC

4.0B 15.4G A SWU 1 2.0B 5.5Q CIBS021 LAN 1)

CB0_112 B NPGE/NPGEP 12 /

NPS1/NPS1P 10

3.0B 15.4G A SWU 1 2.0B 5.5O CIBS018 LAN 1)

CB0_111 B NPGE/NPGEP 11 /

NPS1/NPS1P 9 BISFC

2.0B 17.4G A SWU 1 2.0B 5.5M CIBS014 LAN 1)

CB0_110 B NPGE/NPGEP 10 /

NPS1/NPS1P 8 BISFC

1.0B 17.4G A SWU 1 2.0B 5.5K CIBS018 LAN 1)

CB0_109 B NPGE/NPGEP 9 /

NPS1/NPS1P 7 BISFC

2.0B 15.4G A SWU 1 2.0B 5.5H CIBS014 LAN 1)

CB0_108 B NPGE/NPGEP 8 /

NPS1/NPS1P 6 BISFC

1.0B 15.4G A SWU 1 2.0B 5.5F CIBS018 LAN 1)

1) Cables are connected before the BISFC back interface unit has been installed.

5.3 Intercabinet SFU LVDS lines

Table 17 Intercabinet SFU LVDS cables

CABLE FROM CABLE TO

Equip. No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CB0_200 B MXU 8 /

BISFB

1.0B 9.B00 A SFU 0 /

BISFA

1.0B 2.B08 CSB018 LVDS lines 1)

CB0_201 B MXU 9 /

BISFB

1.0B 11.B00 A SFU 0 /

BISFA

1.0B 2.B09 CSB021 LVDS lines 1)

CB0_202 B MXU 10 /

BISFB

2.0B 9.B00 A SFU 0 /

BISFA

1.0B 2.B10 CSB022 LVDS lines 1)

CB0_203 B MXU 11 /

BISFB

2.0B 11.B00 A SFU 0 /

BISFA

1.0B 2.B11 CSB024 LVDS lines 1)

CB0_204 B MXU 12 /

BISFB

3.0B 9.B00 A SFU 0 /

BISFA

1.0B 2.B12 CSB028 LVDS lines 1)

CB0_205 B MXU13 /

BISFB

3.0B 11.B00 A SFU 0 /

BISFA

1.0B 2.B13 CSB030 LVDS lines 1)

CB0_206 B MXU 14 /

BISFB

4.0B 9.B00 A SFU 0 /

BISFA

1.0B 2.B14 CSB032 LVDS lines 1)

Page 32: Cable List Rnc2600

Cable Lists for RNC2600

32 (41) © Nokia Siemens Networks

DN0938288Issue 1-0

CABLE FROM CABLE TO

Equip. No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CB0_207 B MXU 15 /

BISFB

4.0B 11.B00 A SFU 0 /

BISFA

1.0B 2.B15 CSB032 LVDS lines 1)

CB0_208 B NPGE/NPGEP 8 /

NPS1/NPS1P 6

BISFC

1.0B 15.B00 A SFU 0 /

BISFA

1.0B 2.B24 CSB019 LVDS lines 1)

CB0_209 B NPGE/NPGEP 9 /

NPS1/NPS1P 7

BISFC

2.0B 15.B00 A SFU 0 /

BISFA

1.0B 2.B25 CSB025 LVDS lines 1)

CB0_210 B NPGE/NPGEP 10 /

NPS1/NPS1P 8

BISFC

1.0B 17.B00 A SFU 0 /

BISFA

1.0B 2.B26 CSB019 LVDS lines 1)

CB0_211 B NPGE/NPGEP 11 /

NPS1/NPS1P 9

BISFC

2.0B 17.B00 A SFU 0 /

BISFA

1.0B 2.B27 CSB025 LVDS lines 1)

CB0_212 B NPGE/NPGEP 12 /

NPS1/NPS1P 10

BISFC

3.0B 15.B00 A SFU 0 /

BISFA

1.0B 2.B28 CSB031 LVDS lines 1)

CB0_213 B NPGE/NPGEP 13 /

NPS1/NPS1P 11

BISFC

4.0B 15.B00 A SFU 0 /

BISFA

1.0B 2.B29 CSB034 LVDS lines 1)

CB0_214 B NPGE/NPGEP 14 /

NPS1/NPS1P 12

BISFC

3.0B 17.B00 A SFU 0 /

BISFA

1.0B 2.B30 CSB031 LVDS lines 1)

CB0_215 B NPGE/NPGEP 15 /

NPS1/NPS1P 13

BISFC

4.0B 17.B00 A SFU 0 /

BISFA

1.0B 2.B31 CSB034 LVDS lines 1)

CB0_216 B MXU 8 /

BISFB

1.0B 9.B02 A SFU 1 /

BISFA

2.0B 2.B08 CSB022 LVDS lines 1)

CB0_217 B MXU 9 /

BISFB

1.0B 11.B02 A SFU 1 /

BISFA

2.0B 2.B09 CSB024 LVDS lines 1)

CB0_218 B MXU 10 /

BISFB

2.0B 9.B02 A SFU 1 /

BISFA

2.0B 2.B10 CSB018 LVDS lines 1)

CB0_219 B MXU 11 /

BISFB

2.0B 11.B02 A SFU 1 /

BISFA

2.0B 2.B11 CSB021 LVDS lines 1)

CB0_220 B MXU 12 /

BISFB

3.0B 9.B02 A SFU 1 /

BISFA

2.0B 2.B12 CSB022 LVDS lines 1)

CB0_221 B MXU 13 /

BISFB

3.0B 11.B02 A SFU 1 /

BISFA

2.0B 2.B13 CSB024 LVDS lines 1)

CB0_222 B MXU 14 /

BISFB

4.0B 9.B02 A SFU 1 /

BISFA

2.0B 2.B14 CSB028 LVDS lines 1)

CB0_223 B MXU 15 /

BISFB

4.0B 11.B02 A SFU 1 /

BISFA

2.0B 2.B15 CSB030 LVDS lines 1)

CB0_224 B NPGE/NPGEP 8 /

NPS1/NPS1P 6

BISFC

1.0B 15.B02 A SFU 1 /

BISFA

2.0B 2.B24 CSB025 LVDS lines 1)

Page 33: Cable List Rnc2600

Cable Lists for RNC2600

DN0938288 Issue 1-0

© Nokia Siemens Networks

33 (41)

CABLE FROM CABLE TO

Equip. No

Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CB0_225 B NPGE/NPGEP 9 /

NPS1/NPS1P 7

BISFC

2.0B 15.B02 A SFU 1 /

BISFA

2.0B 2.B25 CSB019 LVDS lines 1)

CB0_226 B NPGE/NPGEP 10 /

NPS1/NPS1P 8

BISFC

1.0B 17.B02 A SFU 1 /

BISFA

2.0B 2.B26 CSB025 LVDS lines 1)

CB0_227 B NPGE/NPGEP 11 /

NPS1/NPS1P 9

BISFC

2.0B 17.B02 A SFU 1 /

BISFA

2.0B 2.B27 CSB019 LVDS lines 1)

CB0_228 B NPGE/NPGEP 12 /

NPS1/NPS1P 10

BISFC

3.0B 15.B02 A SFU 1 /

BISFA

2.0B 2.B28 CSB025 LVDS lines 1)

CB0_229 B NPGE/NPGEP 13 / NPS1/NPS1P 11 BISFC

4.0B 15.B02 A SFU 1 / BISFA

2.0B 2.B29 CSB031 LVDS lines 1)

CB0_230 B NPGE/NPGEP 14 /

NPS1/NPS1P 12

BISFC

3.0B 17.B02 A SFU 1 /

BISFA

2.0B 2.B30 CSB025 LVDS lines 1)

CB0_231 B NPGE/NPGEP 15 /

NPS1/NPS1P 13

BISFC

4.0B 17.B02 A SFU 1 /

BISFA

2.0B 2.B31 CSB031 LVDS lines 1)

1) Cables are connected after the BISFA, BISFB and BISFC back interface units have been installed. Insert the back interface unit carefully. Check that the locking screws are closed properly, and that the back interface unit is in its place.

Page 34: Cable List Rnc2600

Cable Lists for RNC2600

34 (41) © Nokia Siemens Networks

DN0938288Issue 1-0

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

RNACRNBC

Page 35: Cable List Rnc2600

Cable Lists for RNC2600

DN0938288 Issue 1-0

© Nokia Siemens Networks

35 (41)

Figure 4 Routing of intercabinet LVDS cables CB0_001 – CB0_032

Page 36: Cable List Rnc2600

Cable Lists for RNC2600

36 (41) © Nokia Siemens Networks

DN0938288Issue 1-0

6 L3 Data Collector Cables

This chapter presents L3 data collector in RNAC and RNBC.

6.1 L3 Data Collector Cables for RNAC cabinet

Table 18 L3 Data Collector Cables for RNAC cabinet

CABLE FROM CABLE TO

Equip.

No Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CA_250 A ICSU 0 1.0B 03.3B A CPLAN-A Port 4 CHUS014 LAN EL0

CA_251 A RSMU 0 1.0B 04.3B A CPLAN-A Port 2 CHUS014 LAN EL0

CA_252 A OMU 0 1.0B 16.3B A CPLAN-A Port 0 CHUS016 LAN EL1 Optional

CA_253 A ICSU 1 2.0B 03.3B A CPLAN-A Port 5 CHUS021 LAN EL0

CA_254 A RSMU 1 2.0B 04.3B A CPLAN-A Port 3 CHUS021 LAN EL0

CA_255 A ICSU 2 2.0B 06.3B A CPLAN-A Port 6 CHUS021 LAN EL0

CA_256 A OMU 1 2.0B 16.3B A CPLAN-A Port 1 CHUS020 LAN EL1 Optional

CA_257 A ICSU 3 3.0B 01.3B A CPLAN-A Port 7 CHUS024 LAN EL0

CA_258 A ICSU 4 3.0B 02.3B A CPLAN-A Port 8 CHUS024 LAN EL0

CA_259 A ICSU 5 3.0B 03.3B A CPLAN-A Port 9 CHUS024 LAN EL0

CA_260 A ICSU 6 3.0B 04.3B A CPLAN-A Port 10 CHUS024 LAN EL0

CA_261 A ICSU 7 3.0B 14.3B A CPLAN-A Port 11 CHUS025 LAN EL0

CA_262 A ICSU 8 4.0B 01.3B A CPLAN-A Port 12 CHUS025 LAN EL0

CA_263 A ICSU 9 4.0B 02.3B A CPLAN-A Port 13 CHUS026 LAN EL0

CA_264 A ICSU 10 4.0B 03.3B A CPLAN-A Port 14 CHUS026 LAN EL0

CA_265 A ICSU 11 4.0B 04.3B A CPLAN-A Port 15 CHUS026 LAN EL0

CA_266 A ICSU 12 4.0B 05.3B A CPLAN-A Port 16 CHUS026 LAN EL0

CA_267 A ICSU 13 4.0B 14.3B A CPLAN-A Port 17 CHUS027 LAN EL0

Page 37: Cable List Rnc2600

Cable Lists for RNC2600

DN0938288 Issue 1-0

© Nokia Siemens Networks

37 (41)

6.2 L3 Data Collector Cables for RNBC cabinet

Table 19 L3 Data Collector Cables for RNBC cabinet

CABLE FROM CABLE TO

Equip.

No Cab

inet

FU

Position

Cab

inet

FU

Position

Type

Use

Note

CB_250 B ICSU 14 1.0B 01.3B B CPLAN-A Port 0 CHUS016 LAN EL0

CB_251 B ICSU 15 1.0B 02.3B B CPLAN-A Port 1 CHUS016 LAN EL0

CB_252 B ICSU 16 1.0B 03.3B B CPLAN-A Port 2 CHUS016 LAN EL0

CB_253 B ICSU 17 1.0B 04.3B B CPLAN-A Port 3 CHUS016 LAN EL0

CB_254 B ICSU 18 1.0B 05.3B B CPLAN-A Port 4 CHUS016 LAN EL0

CB_255 B ICSU 19 1.0B 14.3B B CPLAN-A Port 5 CHUS018 LAN EL0

CB_256 B ICSU 20 2.0B 01.3B B CPLAN-A Port 6 CHUS018 LAN EL0

CB_257 B ICSU 21 2.0B 02.3B B CPLAN-A Port 7 CHUS018 LAN EL0

CB_258 B ICSU 22 2.0B 03.3B B CPLAN-A Port 8 CHUS018 LAN EL0

CB_259 B ICSU 23 2.0B 14.3B B CPLAN-A Port 9 CHUS018 LAN EL0

CB_260 B ICSU 24 2.0B 05.3B B CPLAN-A Port 10 CHUS018 LAN EL0

CB_261 B ICSU 25 2.0B 14.3B B CPLAN-A Port 11 CHUS020 LAN EL0

CB_262 B ICSU 26 3.0B 01.3B B CPLAN-A Port 12 CHUS021 LAN EL0

CB_263 B ICSU 27 3.0B 02.3B B CPLAN-A Port 13 CHUS021 LAN EL0

CB_264 B ICSU 28 3.0B 03.3B B CPLAN-A Port 14 CHUS021 LAN EL0

CB_265 B ICSU 29 3.0B 04.3B B CPLAN-A Port 15 CHUS021 LAN EL0

CB_266 B ICSU 30 3.0B 05.3B B CPLAN-A Port 16 CHUS021 LAN EL0

CB_267 B ICSU 31 3.0B 14.3B B CPLAN-A Port 17 CHUS024 LAN EL0

CB_268 B ICSU 32 4.0B 01.3B B CPLAN-A Port 18 CHUS026 LAN EL0

CB_269 B ICSU 33 4.0B 02.3B B CPLAN-A Port 19 CHUS026 LAN EL0

CB_270 B ICSU 34 4.0B 03.3B B CPLAN-A Port 20 CHUS026 LAN EL0

CB_271 B ICSU 35 4.0B 04.3B B CPLAN-A Port 21 CHUS026 LAN EL0

CB_272 B ICSU 36 4.0B 05.3B B CPLAN-A Port 22 CHUS026 LAN EL0

CB_273 B ICSU 37 4.0B 14.3B B CPLAN-A Port 23 CHUS028 LAN EL0

Page 38: Cable List Rnc2600

Cable Lists for RNC2600

38 (41) © Nokia Siemens Networks

DN0938288Issue 1-0

7 Physical cable equipping positions and SW port connection coordinates

This section shows the physical cable equipping positions in the subrack and the corresponding SW port connection coordinates, used in hardware configuration management.

The cable connection coordinates are needed when creating internal port connections between plug-in units' ports. For more information, see Creating connection descriptions in Hardware Configuration Management.

For example, for a cable installed in position 1.0B 1.4A, the port connection coordinate in hardware configuration management (WF commands) is B76. See also Figure 5 Notations used in table Physical cable equipping positions and corresponding SW port connection coordinates.

Page 39: Cable List Rnc2600

Cable Lists for RNC2600

DN0938288 Issue 1-0

© Nokia Siemens Networks

39 (41)

2A

C

E

G

J

L

N

P

R

T

V

X

Z

B

D

F

H

K

M

O

Q

S

U

W

Y

3

B1B2...

B25

B76

1

2

3

4

5

4A

...

...

B26

B51

B101

1 23

B76 4A

DN70206639

SW HW SW HW SW HW SW HW SW HWB1 1A B26 2A B51 3A B76 4A B101 5AB2 1B B27 2B B52 3B B77 4B B102 5B

Slot position number

Subrack seen from the rear

1

2

3

4

5

12345678910111213141516171819

1

Figure 5 Notations used in table Physical cable equipping positions and corresponding SW port connection coordinates

Page 40: Cable List Rnc2600

Cable Lists for RNC2600

40 (41) © Nokia Siemens Networks

DN0938288Issue 1-0

Table 18 Physical cable equipping positions and corresponding SW port connection coordinates

SW HW SW HW SW HW SW HW SW HW

B1 1A B26 2A B51 3A B76 4A B101 5A

B2 1B B27 2B B52 3B B77 4B B102 5B

B3 1C B28 2C B53 3C B78 4C B103 5C

B4 1D B29 2D B54 3D B79 4D B104 5D

B5 1E B30 2E B55 3E B80 4E B105 5E

B6 1F B31 2F B56 3F B81 4F B106 5F

B7 1G B32 2G B57 3G B82 4G B107 5G

B8 1H B33 2H B58 3H B83 4H B108 5H

B9 1J B34 2J B59 3J B84 4J B109 5J

B10 1K B35 2K B60 3K B85 4K B110 5K

B11 1L B36 2L B61 3L B86 4L B111 5L

B12 1M B37 2M B62 3M B87 4M B112 5M

B13 1N B38 2N B63 3N B88 4N B113 5N

B14 1O B39 2O B64 3O B89 4O B114 5O

B15 1P B40 2P B65 3P B90 4P B115 5P

B16 1Q B41 2Q B66 3Q B91 4Q B116 5Q

B17 1R B42 2R B67 3R B92 4R B117 5R

B18 1S B43 2S B68 3S B93 4S B118 5S

B19 1T B44 2T B69 3T B94 4T B119 5T

B20 1U B45 2U B70 3U B95 4U B120 5U

B21 1V B46 2V B71 3V B96 4V B121 5V

B22 1W B47 2W B72 3W B97 4W B122 5W

B23 1X B48 2X B73 3X B98 4X B123 5X

B24 1Y B49 2Y B74 3Y B99 4Y B124 5Y

B25 1Z

B50 2Z

B75 3Z

B100 4Z

B125 5Z