CableGlands[1]

Embed Size (px)

Citation preview

  • 5/27/2018 CableGlands[1]

    1/12

    International Metallic

    Cable Gland Solutions

  • 5/27/2018 CableGlands[1]

    2/12

    For more than 100 years, companies have come to rely on

    Cooper Crouse-Hinds for value they can trust to grow theirbusiness. Our comprehensive offering of electrical products

    meet customer application requirements in the most

    demanding industrial and commercial environments

    worldwide.

    Our customer-first commitment to combine premium quality

    and reliability with superior technical support successfully

    minimizes downtime, reduces repair incidence, and improves

    safety and productivity. Every product we develop and every

    solution we engineer is clearly focused on lowering our

    customers total cost of ownership.

    Global termination solutions movingpower and signals in the worlds mostdemanding environments

    From the deserts of

    Africa to the icy

    waters of the North

    Sea, the world turns

    to Cooper Crouse-

    Hinds for its

    complete gland

    solutions. Our cable

    glands are used in

    industrial and

    commercial

    applications

    throughout the world

    engineering safety

    and productivity in

    the most severe

    environmental

    conditions.

    Cooper Crouse-Hinds global offering provides a termination

    solution for virtually every cable type used in hazardous and

    industrial environments. These glands are designed for strict

    adherence to global specifications meeting North American

    and international codes and standards, including NEC, CEC,

    ATEX, IECEx, and regional certifications.

    GLOBAL CABLE GLAND SOLUTIONS2

    Cooper Crouse-Hinds cable glands are the easiest and safest

    solution for your installation and maintenance needs. In any

    electrical or instrumentation installation, our glands are the

    reliable and safe way to move power and signals.

    Global manufacturing presence and local inventory provides for

    flexibility in meeting our customers installation and project

    coordination schedules. The result is best-in-class on-time

    delivery, customer satisfaction, and service. Our first-class

    technical gland team is available to support product application,

    technical specification, and onsite installation training on a

    global basis.

    Global Cable Gland Solutions

  • 5/27/2018 CableGlands[1]

    3/12

    GLOBAL CABLE GLAND SOLUTIONS 3

    International Metallic Cable Gland Solutions

    Complete termination solutions for global cable applications

    Increased safety, flameproof, and explosionproof terminations for

    harsh and hazardous environments Global certifications

    Standard in nickel-plated brass with options for stainless steel,

    aluminum, and bronze

    Full line of accessories, including adapters, unions, and reducers

    Time-tested,quality cableglands

    from CooperCrouse-Hinds offer:

    Complete termination solution for

    global cable applications

    Ease of cable termination providing

    labor and time management

    productivity

    Explosion-protected connections

    contributing to safe operation in

    harsh and hazardous environments

    Delivery meeting installation and

    project coordination schedules

  • 5/27/2018 CableGlands[1]

    4/12

    CABLEGLAND ILLUSTRATION CABLETYPE GLANDTYPE STANDARDMATERIAL CERTIFICATION PROTECTIONTYPEADE 1F

    (page 5)

    Non-armoured

    and armoured

    (does not

    terminate the

    armour)

    Non-

    armoured

    Nickel-

    plated

    brass

    Flameproof &

    Increased Safety

    ADE 4Fpage 6)

    SWA, SWB, STA,

    braided marine

    shipboard and

    lead sheathed

    (with addition of

    earthing washer)

    Armoured Nickel-

    plated

    brass

    Flameproof &

    Increased Safety

    ADE 6Fpage 7)

    SWA, SWB, STA

    and braided

    marine shipboard

    Armoured Nickel-

    plated

    brass

    Flameproof &

    Increased Safety

    ADE 1FCpage 8)

    Non-armoured

    and armoured

    (does not

    terminate the

    armour)

    Non-

    armoured

    Barrier

    Nickel-

    plated

    brass

    Flameproof,

    Increased Safety,

    & Explosionproof

    ADE 6FCpage 9)

    SWA, SWB, STA

    and braided

    marine shipboard

    Armoured

    Barrier

    Nickel-

    plated

    brass

    Flameproof,

    Increased Safety,

    & Explosionproof

    4

    Quick Selection Guide

    International Standards

    QUICK SELECTION GUIDE

    International metallic cable glands also feature Lloyds, DNV, and ABS certifications.

  • 5/27/2018 CableGlands[1]

    5/12

    5

    ADE 1F

    ORDERING EXAMPLE:

    CAP81640 4 KX

    OptionsGland Type

    9 Stainless steel (316L)

    8 Bronze

    7 Aluminum

    5 Silicone sealing ring with temperature range of

    -70C to 220C

    K1 Includes locknut and fiber washer

    K2 Includes locknut, fiber washer, earth tag, and

    shroud

    Features

    Standard material is nickel-plated brass for superior corrosionresistance

    Provides a flameproof and weatherproof seal on the outer sheath of thecable

    Standard neoprene seal suitable for use in operating temperatures ATEX(-60C to 100C), IECEx and cULus (-40C to 100C)

    Available with optional silicone seal for extreme temperatures Available with metric or NPT threads

    See page 10 for related accessories

    Gland TypeNon-armoured

    Cable TypeNon-armoured and armoured(does not terminate the armour)

    Certifications and Compliances LCIE 97ATEX 6008X II 2 GD Exd IIC/Exe II/Ex tD

    IECEx LCI 05.0004X Exd IIC/Exe II/Ex tD

    cULus Listed for Class I, Zone 2 AEx e II/Ex e II cULus Marine Listed for Class I, Zone 1 AEx e II

    /Ex e II

    NEMA 4X and IP68

    CEPEL-EX-558/05X

    GOST-R POCC FR.B03126

    NEPSI N GYJ071336U & GYJ071337U

    DNV N E-10892

    ABS approbation:

    n 10-HS 577243-PDA / P1836754-X

    Lloyds

    OPTIONS (replace lastdigitwith option number):

    F B

    AG E

    SELECTION TABLE

    Gland

    Size

    Entry Thread Size A ThreadLength B

    Metric (NPT)

    Cable Acceptance GlandLength F

    (lessentry)

    Hexagon DimensionsMetric

    Size

    Metric

    Catalog No.

    NPT

    Size

    NPT

    Catalog No.

    Outer Sheath E Across

    Flats

    Across

    Corners GMin. Max.

    4 M12 CAP816404 14" CAP818404 15 (12.0) 4.0 8.0 20.0 16.5

    4 M16 CAP816594 38" CAP818594 15 (12.0) 4.0 8.5 20.0 20.9

    5 M16 CAP816504 38" CAP818504 15 (12.0) 6.0 12.0 22.0 20.9

    4 M20 CAP816674 12" CAP818674 15 (20.2) 4.0 8.5 20.0 26.4

    5 M20 CAP816694 12" CAP818694 15 (20.2) 6.0 12.0 22.0 26.4

    6 M20 CAP816604 12" CAP818604 15 (20.2) 8.5 16.0 25.0 26.4

    5 M25 CAP816774 34" CAP818774 15 (20.2) 6.0 12.0 22.0 33.0

    6 M25 CAP816794 34" CAP818794 15 (20.2) 8.5 16.0 25.0 33.0

    7 M25 CAP816704 34" CAP818704 15 (20.2) 12.0 21.0 27.0 33.0

    7 M32 CAP816894 1" CAP818894 15 (25.3) 12.0 21.0 27.0 39.6

    8 M32 CAP816804 1" CAP818804 15 (25.3) 16.0 27.5 34.0 45.1

    8 M40 CAP816994 1-14" CAP818994 15 (26.0) 16.0 27.5 34.0 48.4

    9 M40 CAP816904 1-1

    4" CAP818904 15 (26.0) 21.0 34.0 36.0 52.89 M50 CAP817094 1-12" CAP819094 15 (26.5) 21.0 34.0 36.0 60.5

    10 M50 CAP817004 1-12" CAP819004 15 (26.5) 27.0 41.0 39.0 60.5

    11 M63 CAP817294 2" CAP819294 17 (27.2) 33.0 48.0 41.0 73.7

    12 M63 CAP817204 2" CAP819204 17 (27.2) 40.0 56.0 43.0 79.2

    12 M75 CAP817394 2-12" CAP819494 18 (40.5) 40.0 56.0 43.0 88.0

    13 M75 CAP817304 2-12" CAP819404 18 (40.5) 47.0 65.0 49.0 93.5

    14 M90 CAP817594 3" CAP819594 22 (42.0) 54.0 74.0 56.0 104.5

    15 M90 CAP817504 3" CAP819504 22 (42.0) 63.0 78.0 61.0 121.0

    16 M110 CAP817794 3-12" CAP819604 22 (43.2) 72.0 92.0 62.0 132.0

    All dimensions in millimeters unless otherwise noted.

    INTERNATIONAL STANDARDS -- FLAMEPROOF & INCREASED SAFETY

  • 5/27/2018 CableGlands[1]

    6/12

    6

    ADE 4F

    INTERNATIONAL STANDARDS -- FLAMEPROOF & INCREASED SAFETY

    Features

    Standard material is nickel-plated brass for superior corrosion resistance

    Armour clamping and bonding with no reversible components for easyinstallation, minimizing error

    Provides flameproof seal on inner jacket and weatherproof seal onouter sheath of cable

    Optional earthing washer for use with lead sheathed cable

    Standard neoprene seal suitable for use in operating temperatures ATEX(-60C to 100C), IECEx and cULus (-40C to 100C)

    Available with optional silicone seal for extreme temperatures

    Available with metric or NPT threads

    See page 10 for related accessories

    Gland TypeArmoured

    Cable TypeSteel wire armoured,steel wire braided, steel tapearmoured, braided marine shipboard and leadsheathed (with addition of earthing washer)

    Certifications and Compliances LCIE 97 ATEX 6008X II 2 GD Exd IIC/Exe II/Ex

    tD

    IECEx LCI 05.0004X Exd IIC/Exe II/Ex tD

    cULus Listed for Class I, Zone 2 AEx e II/Ex e II

    cULus Marine Listed for Class I, Zone 1 AEx e II/

    Ex e II

    NEMA 4X and IP68

    CEPEL-EX-558/05X

    GOST-R POCC FR.B03126

    NEPSI N GYJ071336U & GYJ071337U

    DNV N E-10892

    ABS approbation:

    n 10-HS 577243-PDA / P1836754-X

    Lloyds

    F B

    A DG E

    ORDERING EXAMPLE:

    CAP84640 4 KX

    OptionsGland Type

    9 Stainless steel (316L)

    8 Bronze

    7 Aluminum

    5 Silicone sealing ring with temperature range of

    -70C to 220C

    K1 Includes locknut and fiber washer

    K2 Includes locknut, fiber washer, earth tag, and

    shroud

    OPTIONS (replace lastdigitwith optionnumber):

    All dimensions in millimeters unless otherwise noted.*CAP849604 outer sheath min: 85 max: 107

    SELECTION TABLE

    Gland

    Size

    Entry Thread Size A

    Thread

    Length B

    Metric (NPT)

    Cable Acceptance

    Armour

    (max.)

    Gland

    Length F

    (lessentry)

    Hexagon Dimensions

    Metric

    Size

    Metric

    Catalog No.

    NPT

    Size

    NPT

    Catalog No.

    Inner Sheath D Outer Sheath EAcross

    Flats

    Across

    Corners GMin. Max. Min. Max.

    5 M12 CAP846404 14" CAP848404 15 (12.0) 4.0 8.0 6.0 12.0 0.9 36.0 20.9

    5 M16 CAP846594 38" CAP848594 15 (12.0) 4.0 8.5 6.0 12.0 0.9 36.0 20.9

    6 M16 CAP846504 38" CAP848504 15 (12.0) 6.0 12.0 8.5 16.0 1.25 42.0 26.4

    5 M20 CAP846674 12" CAP848674 15 (20.2) 4.0 8.5 6.0 12.0 0.9 36.0 26.4

    6 M20 CAP846694 12" CAP848694 15 (20.2) 6.0 12.0 8.5 16.0 1.25 42.0 26.4

    7 M20 CAP846604 12" CAP848604 15 (20.2) 8.5 16.0 12.0 21.0 1.25 46.0 33.0

    6 M25 CAP846774 34" CAP848774 15 (20.2) 6.0 12.0 8.5 16.0 1.25 42.0 33.0

    7 M25 CAP846794 34" CAP848794 15 (20.2) 8.5 16.0 12.0 21.0 1.25 46.0 33.0

    8 M25 CAP846704 34" CAP848704 15 (20.2) 12.0 20.5 16.0 27.5 1.6 56.0 45.1

    8 M32 CAP846894 1" CAP848894 15 (25.3) 12.0 21.0 16.0 27.5 1.6 56.0 45.1

    9 M32 CAP846804 1" CAP848804 15 (25.3) 16.0 27.5 21.0 34.0 1.6 63.0 52.8

    9 M40 CAP846994 1-14" CAP848994 15 (26.0) 16.0 27.5 21.0 34.0 1.6 63.0 52.8

    10 M40 CAP846904 1-14" CAP848904 15 (26.0) 21.0 34.0 27.0 41.0 2.0 68.0 60.5

    10 M50 CAP847094 1-12" CAP849094 16 (26.5) 21.0 34.0 27.0 41.0 2.0 68.0 60.5

    11 M50 CAP847004 1-12" CAP849004 16 (26.5) 27.0 41.0 33.0 48.0 2.5 74.0 70.4

    12 M63 CAP847294 2" CAP849294 17 (27.2) 27.0 41.0 33.0 48.0 2.5 77.0 79.2

    13 M63 CAP847204 2" CAP849204 17 (27.2) 33.0 48.0 40.0 56.0 2.5 85.0 93.5

    13 M75 CAP847394 2-12" CAP849494 18 (40.5) 40.0 56.0 47.0 65.0 2.5 85.0 93.5

    14 M75 CAP847304 2-12" CAP849404 18 (40.5) 47.0 65.0 54.0 74.0 2.5 92.0 104.5

    15 M90 CAP847594 3" CAP849594 22 (42.0) 54.0 74.0 63.0 83.0 3.15 104.0 121.0

    16 M90 CAP847504 3" CAP849504 22 (42.0) 63.0 82.0 72.0 93.0 3.15 108.0 132.0

    16 M90 CAP847574 3-12" CAP849604 N/A (43.2) 63.0 82.0 72.0* 93.0* 3.15 108.0 132.0

    17 M110 CAP847794 4" CAP849704 22 (44.5) 72.0 92.0 85.0 107.0 3.15 115.0 148.5

  • 5/27/2018 CableGlands[1]

    7/12

    7INTERNATIONAL STANDARDS -- FLAMEPROOF & INCREASED SAFETY

    ADE 6F

    Features

    Standard material is nickel-plated brass for superior corrosionresistance

    Armour clamping and bonding with no reversible components for easyinstallation, minimizing error

    Provides fully inspectable inner seal after installation

    Flameproof diaphragm seal on inner jacket does not damage cablesexhibiting cold-flow; weatherproof seal on outer sheath of cable

    Deluge boot provides enhanced protection from water ingress

    Standard neoprene seal suitable for use in operating temperatures ATEX(-60C to 100C), IECEx and cULus (-40C to 100C)

    Available with metric or NPT threads

    See page 10 for related accessories

    Gland TypeArmoured with elastomeric diaphragm

    Cable TypeSteel wire armoured, steel wire braided, steeltape armoured and braided marine shipboard

    Certifications and Compliances LCIE 97 ATEX 6008X II 2 GD Exd IIC/Exe II/

    Ex tD

    IECEx LCI 05.0004X Exd IIC/Exe II/Ex tD

    cULus Listed for Class I, Zone 2 AEx e II/Ex e II

    cULus Marine Listed for Class I, Zone 1

    AEx e II/Ex e II

    NEMA 4X and IP68

    CEPEL-EX-558/05X GOST-R POCC FR.B03126

    NEPSI N GYJ071336U & GYJ071337U

    DNV N E-10892

    ABS approbation:

    n 10-HS 577243-PDA / P1836754-X

    Lloyds

    F B

    ADG E

    ORDERING EXAMPLE:

    CAP96559 4 KX

    OptionsGland Type

    9 Stainless steel (316L)

    8 Bronze

    7 Aluminum

    K1 Includes locknut and fiber washer

    K2 Includes locknut, fiber washer, earth tag, and

    shroud

    OPTIONS (replace lastdigitwith option number):

    SELECTION TABLE

    Gland

    Size

    Entry Thread Size A

    Thread

    Length B

    Metric (NPT)

    Cable Acceptance

    Armour

    (max.)

    Gland

    Length F

    (lessentry)

    Hexagon Dimensions

    Metric

    Size

    Metric

    Catalog No.

    NPT

    Size

    NPT

    Catalog No.

    Inner Sheath D Outer Sheath EAcross

    Flats

    Across

    Corners GMin. Max. Min. Max.

    5 M16 CAP965594 38" CAP967594 15 (12.0) 3.0 7.5 6.0 12.0 0.9 46.0 20.9

    5 M20 CAP965674 12" CAP967674 15 (20.2) 3.0 7.5 6.0 12.0 0.9 46.0 26.4

    6 M20 CAP965694 12" CAP967694 15 (20.2) 6.5 11.0 8.5 16.0 1.25 53.0 26.4

    7 M20 CAP965604 12" CAP967604 15 (20.2) 9.0 14.5 12.0 21.0 1.25 59.0 33.0

    7 M25 CAP965794 34" CAP967794 15 (20.2) 9.0 14.5 12.0 21.0 1.25 59.0 33.0

    8 M25 CAP965704 34" CAP967704 15 (20.2) 12.0 19.5 16.0 27.5 1.6 74.5 45.1

    8 M32 CAP965894 1" CAP967894 15 (25.3) 12.0 19.5 16.0 27.5 1.6 74.5 45.1

    9 M32 CAP965804 1" CAP967804 15 (25.3) 17.5 26.0 21.0 34.0 1.6 83.5 52.8

    9 M40 CAP965994 1-14" CAP967994 15 (26.0) 17.5 26.0 21.0 34.0 1.6 83.5 52.8

    10 M40 CAP965904 1-14" CAP967904 15 (26.0) 23.0 33.0 27.0 41.0 2.0 92.0 60.5

    10 M50 CAP966094 1-12" CAP968094 16 (26.5) 23.0 33.0 27.0 41.0 2.0 92.0 60.5

    11 M50 CAP966004 2" CAP968294 16 (27.2) 28.5 41.0 33.0 48.0 2.5 104.0 70.4

    For larger sizes, use ADE 4F design. Please refer to previous page.

    All dimensions in millimeters unless otherwise noted.

  • 5/27/2018 CableGlands[1]

    8/12

    8 INTERNATIONAL STANDARDS -- FLAMEPROOF & INCREASED SAFETY

    ADE 1FC

    Features

    Standard material is nickel-plated brass for superior corrosionresistance

    Provides a flameproof and weatherproof seal on the outer sheath of thecable

    Provides explosionproof compound seal (denoted by red back nut) onconductors

    Deluge boot provides enhanced protection from water ingress

    Standard neoprene seal suitable for use in operating temperatures-60C (-25C UL) to 80C

    Available with metric or NPT threads

    See page 10 for related accessories

    Gland TypeNon-armoured barrier

    Cable TypeNon-armoured, armoured and tray cable(does not terminate the armour)

    Certifications and Compliances LCIE 97ATEX 6008X II GD Exd IIC/Exe II/Ex tD

    IECEx LCI 05.0004X Ex c e IIC/Ex c e II/Ex tD cULus Listed for Class I, Zone 2 AEx de II/Ex de II

    UL Marine Listed for Class I, Division 2, Groups

    A, B, C, D

    NEMA 4X and IP68

    CEPEL EX-558/05X

    GOST-R POCC FR.B03126

    NEPSI N GYJ071336U & GYJ071337U

    DNV N E-10892

    ABS approbation:

    n 10-HS 577243-PDA / P1836754-X

    Lloyds

    F B

    A GE

    All dimensions in millimeters unless otherwise noted.*Aluminum not currently available with UL marine certification.

    **Contact Customer Service or your sales representative for amended UL marine range.

    SELECTION TABLE

    Gland

    Size

    Entry Thread Size AThread

    Length B

    Metric (NPT)

    Cable AcceptanceMax

    No.

    Cores

    Gland

    Length F

    (less entry)

    Hexagon Dimensions

    Metric

    Size

    Metric

    Catalog No.

    NPT

    Size

    NPT

    Catalog No.

    Outer SheathE Across

    Flats

    Across

    Corners GMin. Max.

    4 M16 CAP019594 38" CAP011594 15 (12.0) 4.0 7.5 6.0 46.0 - 20.9

    4 M20 CAP019674 12" CAP011674 15 (22.2) 4.0 7.5 6.0 46.0 - 26.4

    5 M20 CAP019694 12" CAP011694 15 (22.2) 6.5 11.0 6.0 53.0 - 26.4

    6 M20 CAP019604 12" CAP011604 15 (22.2) 9.0 14.5 10.0 59.0 - 33.0

    6 M25 CAP019794 34" CAP011794 15 (22.5) 9.0 14.5 10.0 59.0 - 33.0

    7 M25 CAP019704 34" CAP011704 15 (22.5) 12.0 19.5 21.0 74.5 - 45.1

    7 M32 CAP019894 1" CAP011894 15 (27.3) 12.0 19.5 21.0 74.5 - 45.1

    8 M32 CAP019804 1" CAP011804 15 (27.3) 17.5 26.0 42.0 83.5 - 52.8

    8 M40 CAP019994 1-14" CAP011994 15 (28.0) 17.5 26.0 42.0 83.5 - 52.8

    9 M40 CAP019904 1-14" CAP011904 15 (28.0) 23.0 33.0 60.0 92.0 - 60.5

    9 M50 CAP019094 1-12" CAP011094 16 (28.5) 23.0 33.0 60.0 92.0 - 60.5

    10 M50 CAP019004 2" CAP011004 16 (29.2) 28.5 41.0 80.0 104.0 - 70.4

    10 M63 CAP019204 - - 16 28.5 41.0 80.0 - - 73.7

    11 M63 CAP019294 2" CAP011294 17 (29.2) 43.0 48.0 100.0 98.0 - 70.4

    12 M63 CAP019274 2" CAP011204 17 (29.2) 50.0 56.0 100.0 103.0 - 79.2

    12 - - 2-12" CAP011494 42.5 50.0 56.0 100.0 103.0 - 79.2

    13 M75 CAP019304 2-12" CAP011404 18 (42.5) 59.0 65.0 120.0 111.0 - 93.5

    13 - - 3" CAP012504 44 59.0 65.0 120.0 111.0 - 93.5

    14 M90 CAP010594 3" CAP012574 22 (44.0) 66.0 73.0 140.0 120.0 - 104.5

    14 - - 3-12" CAP012604 45.2 66.0 73.0 140.0 120.0 - 104.5

    15 M90 CAP010504 3" CAP012594 22 (44.0) 75.0 82.0 140.0 125.0 - 121.0

    15 - - 3-12" CAP012694 45.2 75.0 82.0** 140.0 125.0 - 121.0

    16 M110 CAP010794 4" CAP012704 22 (46.5) 85.0 92.0** 200.0 128.0 - 132.0

    ORDERING EXAMPLE:

    CAP01959 4 KX

    OptionsGland Type

    9 Stainless steel (316L)

    8 Bronze

    7 Aluminum*

    K1 Includes locknut and fiber washer

    K2 Includes locknut, fiber washer, earth tag, and

    shroud

    OPTIONS (replace lastdigitwith optionnumber):

  • 5/27/2018 CableGlands[1]

    9/12

    9INTERNATIONAL STANDARDS -- FLAMEPROOF & INCREASED SAFETY

    ADE 6FC

    SELECTION TABLE

    Gland

    Size

    Entry Thread Size A

    Thread

    Length B

    Metric

    (NPT)

    Cable Acceptance

    Armour

    (Max.)

    Gland

    Length

    F

    (less entry)

    Hexagon Dimensions

    Metric

    Size

    Metric

    Catalog No.

    NPT

    Size

    NPT

    Catalog No.

    Inner Sheath and Cores Outer Sheath E

    Across

    Flats

    Across

    Corners G

    Max Over

    Cores

    C

    Max Inner

    Sheath

    D

    Max No.

    of Cores Min. Max.

    5 M16 CAP969594 38" CAP974594 15 (12.0) 6.5 7.5 6.0 6.0 12.0 0.9 46.0 - 20.9

    5 M20 CAP969674 12" CAP971674 15 (20.2) 6.5 7.5 6.0 6.0 12.0 0.9 46.0 - 26.4

    6 M20 CAP969694 12" CAP971694 15 (20.2) 9.5 11.0 6.0 8.5 16.0 1.25 53.0 - 26.4

    7 M20 CAP969604 12" CAP971604 15 (20.2) 12.0 14.5 10.0 12.0 21.0 1.25 59.0 - 33.0

    7 M25 CAP969794 34" CAP971794 15 (20.5) 12.0 14.5 10.0 12.0 21.0 1.25 59.0 - 33.0

    8 M25 CAP969704 34" CAP971704 15 (20.5) 17.0 19.5 21.0 16.0 27.5 1.6 74.5 - 45.1

    8 M32 CAP969894 1" CAP971894 15 (25.3) 17.0 19.5 21.0 16.0 27.5 1.6 74.5 - 45.1

    9 M32 CAP969804 1" CAP971804 15 (25.3) 23.0 28.0 42.0 21.0 34.0 1.6 83.5 - 52.8

    9 M40 CAP969994 1-14" CAP971994 15 (26.0) 23.0 28.0 42.0 21.0 34.0 1.6 83.5 - 52.8

    10 M40 CAP969904 1-14" CAP971904 15 (26.0) 29.0 33.0 60.0 27.0 41.0 2.0 92.0 - 60.5

    10 M50 CAP970094 1-12" CAP972094 15 (26.5) 29.0 33.0 60.0 27.0 41.0 2.0 92.0 - 60.511 M50 CAP970004 2" CAP972004 16 (27.2) 36.5 41.0 80.0 33.0 48.0 2.5 104.0 - 70.4

    12 M63 CAP970294 2" CAP972274 17 (29.2) 43.0 48.0 100.0 40.0 56.0 2.5 108.0 - 79.2

    13 M63 CAP970204 2" CAP972204 17 (29.2) 50.0 56.0 100.0 46.0 65.0 2.5 118.0 - 93.5

    13 M75 CAP970394 2-12" CAP972494 18 (42.5) 50.0 56.0 100.0 46.0 65.0 2.5 118.0 - 93.5

    14 M75 CAP970304 2-12" CAP972404 18 (42.5) 59.0 65.0 120.0 54.0 74.0 2.5 124.0 - 104.5

    14 - - 3" CAP972574 (44) 59.0 65.0 120.0 54.0 74.0 2.5 124.0 - 104.5

    15 M90 CAP970594 3" CAP972594 22 (44.0) 66.0 73.0 140.0 63.0 83.0 3.15 133.0 - 121.0

    15 - - 3-12" CAP972694 (45.2) 66.0 73.0 140.0 63.0 83.0 3.15 133.0 - 121.0

    16 M90 CAP970504 3" CAP972504 22 (44.0) 75.0 82.0 140.0 72.0 93.0 3.15 137.0 - 132.0

    16 - - 3-12" CAP972604 (45.2) 75.0 82.0** 140.0 72.0 93.0 3.15 137.0 - 132.0

    17 M110 CAP970794 4" CAP972704 22 (46.5) 85.0 92.0** 200.0 85.0 107.0 3.15 142.0 - 148.5

    Features

    Standard material is nickel-plated brass for superior corrosionresistance

    Armour clamping with no reversible components for easy installation,minimizing error

    Provides explosionproof compound seal (denoted by red back nut) onconductors and weatherproof seal on outer sheath of cable

    Deluge boot provides enhanced protection from water ingress Standard neoprene seal suitable for use in operating temperatures

    -60C (-25C UL) to 80C

    Available with metric or NPT threads

    See page 10 for related accessories

    Gland TypeArmoured barrier

    Cable TypeSteel wire armoured,steel wire braided, steel tapearmoured, braided marine shipboard and leadsheathed (with addition of earthing washer)

    Certifications and Compliances ATEX LCIE 97ATEX 6008X Exd IIC/Exe II/Ex tD/

    Ex II 2 GD

    IECEx LCI 05.0004X

    cULus Listed for Class I, Zone 2 AEx de II/Ex de II

    cULus Marine Listed for Class I, Division 1,Groups A, B, C, D

    NEMA 4X and IP68

    CEPEL-EX-558/05X

    GOST-R POCC FR Bo2011

    NEPSI N GYJ071336U & GYJ071337U

    ABS approbation:

    n 10-HS 577243-PDA / P1836754-X

    DNV N E-10892

    Lloyds

    F B

    ADCG E

    ORDERING EXAMPLE:

    CAP96959 4 KX

    OptionsGlandType

    9 Stainless steel (316L)

    8 Bronze

    7 Aluminum*

    K1 Includes locknut and fiber washer

    K2 Includes locknut, fiber washer, earth tag, and

    shroud

    OPTIONS (replace lastdigitwith option number):

    All dimensions in millimeters unless otherwise noted.

    *Aluminum not currently available with UL marine certification.**Contact Customer Service or your field sales representative for amended UL marine range.

  • 5/27/2018 CableGlands[1]

    10/12

    ACCESSORIES10

    Accessories

    Cooper Crouse-Hinds offers the most extensive offering of accessories to meet

    the needs of any installation

    Accessories include: Adapters Reducers Unions Stopping Plugs Breathers / Drains Locknuts Washers Earth Tags Shrouds

  • 5/27/2018 CableGlands[1]

    11/12

    11REFERENCE GUIDE

    Reference Guide

    General Terms

    Ambient Temperature All encompassing temperature within a given area

    Armour Mechanical protection usually accomplished by a metallic

    layer of tape, braid or served wires; normally found underthe outer sheath of a cable

    Armoured Cable A cable provided with a wrapping of metal, usually steelwires, flat tapes, or interlocked tapes, primarily for thepurpose of mechanical protection

    ATEX French term Atmosphres Explosibles (EU directive94/9/EC)

    AWG American Wire Gauge

    Braid Armour A fibrous or metallic group of filaments interwoven incylindrical form covering one or more conductors

    Cable Gland A device used for the entry of cables or cords into electricalequipment providing armour clamping, sealing and/or strainrelief

    CB Certification Body

    Cold Flow Any permanent deformation of the inner sheath of a cabledue to pressure or mechanical force, without the aid of heatsoftening

    CWCMC Continuously Welded Corrugated Metal-clad Cable

    DTS01 Deluge Test developed by Shell, mainly used on offshorerigs

    Directive A legislative act of the European Union

    EHSR Essential Health and Safety Requirements Requirementsfrom new approach Directives, e.g. LVD, ATEX

    Hazardous Location where fireor explosion hazards mayexist dueLocation to the presenceof flammable gases, dusts, or fibers

    IECEx CB IECEx Certifying Body

    IECEx TR IECEx Test Report

    IP Ingress Protection

    ITC Instrument tray cable

    ITC-HL Instrument Tray Cable Hazardous Location

    LVD Low Voltage Directive (EU directive 2006/95/EC)

    MC Metal-clad Cable

    MC-HL Metal-clad Cable-Hazardous Location, for Class I, Division

    1 locationsMI Mineral Insulated

    MV Medium Voltage

    NB Notified Body

    PLTC Power Limited Tray Cable

    Primary Seal A seal that isolates process fluids from an electricalsystem and has one side of the seal in contact with theprocess fluid

    QAR Quality Assurance Report quality portion of IECExcertification

    QAN Quality Assurance Notice quality portion of ATEXcertification

    Secondary Seal A seal that is designed to prevent the passage of processfluids at the pressure it will be subjected to upon failure ofthe primary seal (secondary seals are required for sealingconduits and cables in Class I explosive gas atmospheres,where failure of a primary seal could allow flammableprocess fluids to leak into electrical equipment, withdisastrous results)

    SWA SteelWireArmour

    STA Steel Tape Armour (also DSTA fordoublesteelwire armour)

    SWB Steel Wire Braid

    TC Tray Cable

    TC-ER Tray Cable Exposed Run

    TECK A type of metal-clad interlocked armour cable (mainlyused in Canada)

    Wet Locations Installations underground or in concrete slabs or masonryin direct contact with the earth; locations subject tosaturation with water or other liquids, such as wash downareas; and in unprotected locations exposed to weather

    AWG to mm2 Conversion Table

    AWG Diameter mm) Area mm2) Diameter in)30 0.252 0.05 0.010

    28 0.319 0.08 0.013

    26 0.422 0.14 0.017

    24 0.564 0.25 0.022

    22 0.658 0.34 0.026

    20 0.798 0.50 0.031

    18 0.977 0.75 0.038

    16 1.382 1.50 0.054

    14 1.784 2.50 0.070

    12 2.257 4.0 0.089

    10 2.764 6.0 0.109

    8 3.568 10.0 0.140

    6 4.514 16.0 0.178

    AWG Diameter mm) Area mm2) Diameter in)4 5.642 25 0.222

    2 6.676 35 0.263

    1 7.979 50 0.314

    1/0 8.368 55 0.329

    2/0 9.441 70 0.372

    3/0 10.998 95 0.433

    4/0 12.361 120 0.487

    300MCM 13.820 150 0.544

    350MCM 15.348 185 0.604

    500MCM 17.481 240 0.688

    600MCM 19.544 300 0.769

    750MCM 22.568 400 0.888

    1000MCM 25.231 500 0.993

  • 5/27/2018 CableGlands[1]

    12/12

    Printed in USA5031-0212

    U.S. (Global Headquarters):

    Cooper Crouse-Hinds

    Wolf & Seventh North Streets

    Syracuse, NY 13221

    (866) 764-5454

    FAX: (315) 477-5179

    FAX Orders Only: (866) 653-0640

    [email protected]

    Canada:

    Cooper Crouse-Hinds Canada

    Toll Free: 800-265-0502

    FAX: (800) 263-9504

    FAX Orders only: (866) 653-0645

    Mexico/Latin America/Caribbean:

    Cooper Crouse-Hinds, S.A. de C.V.

    52-555-804-4000

    FAX: 52-555-804-4020

    [email protected]

    Middle East (Dubai):

    Cooper Crouse-Hinds LLC

    971 4 4272500

    FAX: 971 4 4298521

    [email protected]

    Korea:

    Cooper Crouse-Hinds Korea

    82 2 538 342582 2 538 3505

    [email protected]

    Europe (Germany):

    Cooper Crouse-Hinds GmbH

    49 (0) 6271 806-500

    49 (0) 6271 806-476

    [email protected]

    China:

    Cooper Crouse-Hinds Pte. Ltd.

    86-21-2899-3600FAX: 86-21-2899-4055

    [email protected]

    India:

    Cooper India Pvt. Ltd.

    91-124-4683888

    FAX: 91-124-4683899

    [email protected]

    Australia:

    Cooper Electrical Australia

    61-2-8787-2777FAX: 61-2-9609-2342

    [email protected]

    Singapore:

    Cooper Crouse-Hinds Pte. Ltd.

    65-6297-4849

    FAX: 65-6297-4819

    [email protected]

    For more information:If further assistance is required, please contact an authorized Cooper Crouse-Hinds Distributor,

    Sales Office, or Customer Service Department.

    Your Authorized Cooper Crouse-Hinds Distributor is:

    Cooper Industries, Ltd.

    600 Travis, Ste. 5800

    Houston, TX 77002-1001

    P: 713-209-8400

    www.cooperindustries.com

    www.crouse-hinds.comCooper Crouse-Hinds is a registered trademark of Cooper Industries, Inc.

    2012 Cooper Industries, Inc.