4
Guide System Accurate guiding of instruments and implants Easy and convenient to use Single-use products – direct application of surgical instruments Compatible with several planning systems GUIDE SYSTEM TEMPLATE-GUIDED IMPLANTATION

Camlog conelog flyer guide system 2014 international (1)

  • Upload
    camlog

  • View
    218

  • Download
    0

Embed Size (px)

DESCRIPTION

 

Citation preview

Page 1: Camlog conelog flyer guide system 2014 international (1)

Guide System

Accurate guiding of instruments and implantsEasy and convenient to useSingle-use products – direct application of surgical instrumentsCompatible with several planning systems

GUIDE SYSTEM TEMPLATE-GUIDED IMPLANTATION

Page 2: Camlog conelog flyer guide system 2014 international (1)

ALL ADvANTAGES AT A GLANcE• Straightforwardwell-arrangedsystemdueto

smallnumberofrequiredparts• High precision level due to well matched

products–“allfromasinglesource”• Color-codedsingle-usedrills,gingivapunches,

insertionpostsandguidesleeves• Convenienttouse,asadditionalsleevesand

depthstopsarenotrequired• Choicebetweenseveralplanningsystems• Consistentimplementationofalladvantages

ofsoftware-based3Dimplantplanning

• Accuratepreparationoftemporaryrestorationanditsimmediateintegration

• Noinvestmentinadditionalinstrumenttraysnecessary

• Optimal edge holding and hygiene of thecuttinginstrumentsduetosterilityandsingleuse

• Whenoptingforlaboratoryfabricationofthedrilltemplate,valuecreationremainswiththedentallaboratory

Guide System

GUIDE SYSTEM – OPTIMALLY MATcHED cOMPONENTSThecomponentsoftheGuideSystemservethetemplate-guidedpreparationoftheimplantbedand insertion of CAMLOG® and CONELOG®SCREW-LINE implants, Promote® plus, in apartially or fully edentulous maxilla andmandible.

THE GUIDE SYSTEM cOMPRISES:• Laboratoryinstrumentsforfabricatingadrill

template and a pre-operative interimprosthesisonamastermodel

• Surgicalinstrumentsfortemplate-guidedboneor tooth-supported implant bed preparationandimplantinsertion

• Guide System CAMLOG® SCREW-LINEimplants,Promote®plus,withthefollowingdimensions[mm]:

Length Ø3.3 Ø3.8 Ø4.3

9 –

11

13

16

• Guide System CONELOG® SCREW-LINEimplants,Promote®plus,withthefollowingdimensions[mm]:

Length Ø3.3 Ø3.8 Ø4.3

7 –

9

11

13

16

MORE INFORMATION AND THE GUIDE SYSTEM vIDEO AT:

www.camlog.com/products/digital-technique

GuideSystem

GUIDE SYSTEM – SAFE IMPLANTATION AND IMMEDIATE TEMPORARY RESTORATION

Settingtoolforexactintegrationoftheguidesleeveintothedrilltemplate

Insertionpost,color-coded

Templatedrilltoprepareguidesleevedrillholes

Driverwithhexagonformanualimplantinsertion

Guidesleeve,color-coded

GuideSystemCAMLOG®andCONELOG®SCREW-LINEimplants,Promote®plus,includingpre-mountedinsertionpostswithguidingshaftanddepthstopforpreciseinsertiontoplannedplacementdepth

DriverwithISOshaftformechanicalimplantinsertion

Checkuppinforcheckingcorrectalignmentoftheguidesleevesinthetemplate

GuideSystem

Page 3: Camlog conelog flyer guide system 2014 international (1)

Guide System

Pilotdrillsforoptionaluseinlateralbonecondensationortoensurecorrectalignmentofthedrillingaxisunderdifficultanatomicalcircumstances

Allsurgicaldrillsarefittedwithcircumferentialcolorcodingontheshaftandlasermarkingswithlengthanddiametertoensurefastandclearassignment.

Guidedgingivapunchfortransgingivalminimalinvasivepreparationofthesofttissue

Preandformdrillsforreliableguidance–evenatgreaterdrillingdepths–throughstepwisepreparationoftheimplantbedtotheplannedplacementdepth

FormDrillCorticalBone,foroptionaluseinboneclasses1and2*

PREcISION WITH 3D PLANNING – SAFETY FOR PATIENTS AND USERS3Dplanningwithanimplantplanningsoftwareand implementation with the Guide Systemoffers the user simple, predictable and safeimplant bed preparation. While planning theprecise implant positioning, all physiologicalstructurescanbeconsidered.

DRILL TEMPLATE WITH DEPTH STOPThe Guide System Guiding sleeves can beintegrated in the drilling templateswhich arefabricated via conventional techniques in thelaboratoryorwiththeaidofcomputer-guidedmethodssuchasCNCmilling,stereolithographyor3Dprinting.In the case of computer-guidedmethods, thelaboratoryinstrumentsarenotrequiredforthefabricationandcheckingofthetemplate.

Aftercompletion,thedrilltemplateservesto:• position lab analogs during preoperative

fabricationofthemodelandthetemporaryrestoration

• guiding surgical instruments of the GuideSystemduringimplantbedpreparation

• guiding the Guide System SCREW-LINEimplantsduringinsertion.

TEMPORARY RESTORATION OPTION IMMEDIATELY FOLLOWING IMPLANTATIONDue to theprecise 3Dplanningoptionof theimplantpositions,thetemporaryrestorationcanalreadybefabricatedpriortoactualsurgerywiththeaidof thedrillingtemplateandtheGuideSysteminsertionpostsfor laboratoryanalogs.This means that the patient can be restoredtemporarilyimmediatelyaftersurgery.

*Lekholm&Zarb,1985

Page 4: Camlog conelog flyer guide system 2014 international (1)

Guide System

Implantology without 3-dimensional implantplanning is unthinkable today. Today, highprecision and accurate planning programsenable the fabrication of precise surgerytemplates. Thismakes it evenmore importantto find simple tools with which planning canbe implemented for surgery. For this reason IusetheGuideSystembyCAMLOG,asitgreatly

simplifies surgical intervention with just a single sleeve. The perfectmatchoftemplate,sleeveanddrillsetallowsmetoconcentratefullyontheindividualpatientcase.Inaddition,theCAMLOGGuideSystemdoesnottiemetoaspecificplanningsystem.Thisfreedomisimportanttomeaspracticeowner.

Dr. Claudio Cacaci | Munich

Rightstochangesreserved·X.J6234.06

/2014

HEADQUARTERSCAMLOGBiotechnologiesAG|Margarethenstrasse38|[email protected]|www.camlog.com

ManufacturerofCAMLOG®andCONELOG®products:ALTATECGmbH,Maybachstraße5,D-71299Wimsheim

Theoverall benefit ofGuided Surgery only comesinto its own if implementation is performedpreciselyandconsistently.Thismeanscontinuingwithguidedoperationafterpilotdrillingandalsoinsertingtheimplantwiththetemplate.This is theonlyway tobeassured thatall planning criteria have been implemented. Thenecessarydrillsetshavealreadybeenofferedbya

numberofimplantmanufacturers.The easiest, most precise and clearly arranged drill set is the CAMLOGGuideSystem.Itisconvenienttouse,asadditionalsleevesanddepthstopsarenotrequired.Allworksteps,frompunchingthegingivatoinsertingtheimplant,canbeperformedbyjustusingasinglesleeve.MyclinicianslovetheCAMLOGGuideSystem.

MDT Gerhard Stachulla | Bergen

A correct diagnosis and good planning arethe basis for successful work. High precision,absolute control and minimal trauma areessential for performing implant surgery today.For this reason, one of the biggest advancesin my surgery has been the CAMLOG GuideSystem in combination with the option ofimplementing immediate loading easier and

simpler.Additional,clearresultsareanimprovedcommunicationwithpatientsaswellasthepeaceofmindandthesecurityforbothsides.

Dr. Juan Zufia | Madrid

InmyopiniontheCAMLOGGuideSystemembodiesaconvenientandpredictablemethodandconveysaperfectfeelingfromaclinicalstandpoint.The reduced number of drills and the option ofworkingwithout additional depth stop, simplifiesand accelerates the clinical protocol compared tomostothersystemsavailableonthemarket.Color-codingmakes theguidesleeveseasy toassign to

thecorrespondingimplantdiameterandisextremelyprecise.Thesimplifieddrillingsequenceandtheexcellentcuttingperformanceofthedrillsallowarapidpreparationoftheimplantbed.ThecorrespondingGuideinsertionpostsensuresafeandaccuratepositioningoftheimplant.

Dr. Mario Beretta | Milan