Upload
martins-victor
View
51
Download
2
Embed Size (px)
Citation preview
11/15/13 Chapter3
web.mst.edu/~numbere/cp/chapter 3.htm 1/26
3 CAPILLARY PRESSURE
What Causes Capillary Pressure?3.1 EXPRESSIONS FOR CAPILLARY PRESSURE UNDER STATIC CONDITIONS
3.1.1 Pc In terms of radius of capillary tube
3.1.2 Pc In terms of height of fluid column.
3.1.3 Pc In terms of radii of curvature of interface
3.1.4 Application to Parallel Plates3.2 APPLICATIONS OF CAPILLARY PRESSURE EXPRESSIONS IN POROUS MEDIA
3.2.1 Application to obtain static fluid distribution in porous media
3.2.2 Porous media modelled as a bundle of capillaries3.2.3 Porous media modelled as a packaging of uniform spheres
3.3 Laboratory methods of measuring capillary pressure3.3.1 Centrifugal Method
3.3.2 Mercury Injection Method
3.3.3 Porous Diaphragm Method3.4 Other methods
3.4.1 Field Method :
3.4.2 Capillary Hysteresis
3.4.3 Explanations for capillary hysteresis
3.4.4 The effect of pore size distribution on capillary pressure curve3.4.5 Conversion of Laboratory Capillary Data to Reservoir Capillary Data
3.4.6 Calculating Average water saturation
3.5 Averaging Capillary Pressure Curves3.5.1 Leverett J-function
3.5.2 How to use the Leverett J-function to calculate Average Water Saturation
3.5.2.1 Case 1: Permeability, Porosity, and Elevation are known for each sample3.5.2.2 The correct method
3.5.2.3 Errors due to using average values of and
3.5.2.4 Case 2: Permeability and porosity are unknown as functions of elevation. Distance from (distance from free-watertable) is known
11/15/13 Chapter3
web.mst.edu/~numbere/cp/chapter 3.htm 2/26
3 CAPILLARY PRESSURE
Reservoir rock typically contains the immiscible phases: oil, water, and gas. The forces that hold these fluids in equilibrium with each other
and with the rock are expressions of capillary forces. During waterflooding, these forces may act together with frictional forces to resist the
flow of oil. It is therefore advantageous to gain an understanding of the nature of these capillary forces.
Definition : Capillary pressure is the pressure difference existing across the interface separating two immiscible fluids.
If the wettability of the system is known, then the capillary pressure will always be positive if it is defined as the difference between the
pressures in the non-wetting and wetting phases. That is:
Thus for an oil-water system (water wet)
For a gas-oil system (oil-wet)
What Causes Capillary Pressure?
Capillary pressure is as a result of the interfacial tension existing at the interface separating two immiscible fluids. The interfacial tension itself iscaused by the imbalance in the molecular forces of attraction experienced by the molecules at the surface as shown below.
For molecules in the interior: Net forces = 0 since there are enough molecules around to
balance out.For molecules on the surface:
Net result of forces is a pull toward the interior causing a tangentialtension on the surface.The net effect of the interfacial tension is to try to minimize the interfacial area in a manner analogous to the tension in a stretched membrane.
To balance these forces and to keep the interface in equilibrium, the pressure inside the interface needs to be higher than that on the outside.Forces reducing interface are due to: a) Interfacial tension b) External pressure
The effect of interfacial tension is to compress the non-wetting phase relative to the wetting phase. The force created by the internal pressureis balancing it.
3.1 EXPRESSIONS FOR CAPILLARY PRESSURE UNDER STATIC CONDITIONS
3.1.1 Pc In terms of radius of capillary tube
Since the interface is in equilibrium, force can be balanced on any segment. The interfacial forces are eliminated by taking as a free body, thatpart of the interface not in direct contact with the solid. A force balance would give:
(Internal pressure - External pressure) * Cross-sectional area = Interfacial tension * Circumference
11/15/13 Chapter3
web.mst.edu/~numbere/cp/chapter 3.htm 3/26
Thus,
Therefore,
And since by definition, , we have:
For an air-water system, the air is the non-wetting phase and This equation is referred to as Laplace's Equation in some texts.
3.1.2 Pc In terms of height of fluid column.
because there is no capillary pressure across a horizontal interface.
but
therefore,
Since then
Oil-water system
because no capillary exists across any interface that is horizontal.
11/15/13 Chapter3
web.mst.edu/~numbere/cp/chapter 3.htm 4/26
Since , then,
Therefore,
That is,
Cgs Units: Field Units:
The two expressions for capillary pressure in a tube, one in terms of height of a fluid column and the other in terms of the radius of thecapillary tube can be combined to give an expression for the height of a fluid column in terms of the radius of the tube as follows:
Therefore for an air-water system,
Similarly, for an oil-water system,
These two equations show an inverse relationship between fluid height and capillary radius. The smaller the radius is, the higher the height of
the fluid column will be.
Example 3.1
a) Derive the expression for the pressure at the bottom of a capillary tube containing oil and water and exposed to the atmosphere as shownbelow.
11/15/13 Chapter3
web.mst.edu/~numbere/cp/chapter 3.htm 5/26
b) If , , and , and the radius of the tube is 1 cm. What is the value of the
pressure at the bottom of the tube ?
.
Solution
Consider points (1) and (2) at the air/oil and water/oil interfaces respectively.
(1)
(2)
From . we obtain
Since,
Solving for Pcow gives;
(3)
b) Substituting values,
3.1.3 Pc In terms of radii of curvature of interface
The dependence of on the curvature of the interface is analyzed with reference to the figure below. This figure represents a small segment
of a curved interface containing the point p. The point is at the center of the segment, which is approximately square in shape. The edges of
the segment are each of length . The angles and are those subtended by each arc of half length on orthogonal planes normal to the
segment at p, with radii of curvature R1 and R2 respectively.
11/15/13 Chapter3
web.mst.edu/~numbere/cp/chapter 3.htm 6/26
NOTE: and are the radii of curvature of the interface itself and have nothing to do with the radius of any tube.
By balancing forces
therefore,
This is the general expression for capillary pressure that is applicable to all systems regardless of shape. For example, it can be applied to the
case of two parallel plates standing in water.
3.1.4 Application to Parallel Plates
Consider two parallel glass plates separated by a gap to a fluid standing in water. The expression for capillary pressure and the height to
which the fluid will rise between the plates can be obtained from the general expression for capillary pressure in terms of the radii of the
interface as follows:
11/15/13 Chapter3
web.mst.edu/~numbere/cp/chapter 3.htm 7/26
In general,
For the case of parallel plates, , and
Therefore,
That is, , where is the contact angle.
Please note that even though this equation looks similar to that of a tube, the denominators are not the same. In this case, b is the separationbetween the plates, and not the radius of any tube.
The height to which the fluid will rise can be obtained by equating the two expressions:
Therefore,
Example 3.2
Consider three capillary tubes having respectively:
a) a circular cross-section
b) a square cross-section
c) a rectangular cross-section with one side having twice the dimension of the other.
If all three tubes have the same cross-sectional area and same wettability, which tube will have the highest capillary rise?
Solution
The formula to use is ……………..….(a)
For the circular cross-section,
Since the radius of the tube = = , then,
………………………(b)
For the square cross-section, the length of each side
………………………(c)
For the rectangular cross-section, since ,
11/15/13 Chapter3
web.mst.edu/~numbere/cp/chapter 3.htm 8/26
Substituting for R1 and R2 in the general equation (equation (a)) gives:
……………………..(d)
Since all three have the same cross-sectional area ,
Substituting for in equations (c) gives:
…………for the square
Similarly, substituting for in equation (d) gives:
…………………for the rectangle
The appropriate equations are now:
tube square rectangle
Since and
Thus, the rectangle will have the highest capillary rise, followed by the square and the circle last.
3.2 APPLICATIONS OF CAPILLARY PRESSURE EXPRESSIONS IN POROUS MEDIA
3.2.1 Application to obtain static fluid distribution in porous media
3.2.2 Porous media modelled as a bundle of capillaries
11/15/13 Chapter3
web.mst.edu/~numbere/cp/chapter 3.htm 9/26
One of the earliest and simplest depiction of porous media was as a bundle of capillary tubes of arbitrarily varying diameters. By applying the
applicable one of the equations:
or
The different water heights in such a system is illustrated in the figure below where if the number of tubes were numerous, a smooth curve will
result as shown in the lower figure. That figure is for a three-phase gas-oil-water system. The figures also show the difference between the
water-oil contact (WOC) and the free-water table. The WOC is the depth at which begins (moving downward) while the free-
water table is the depth at which .
11/15/13 Chapter3
web.mst.edu/~numbere/cp/chapter 3.htm 10/26
3.2.3 Porous media modelled as a packaging of uniform spheres
An even more realistic model is the depiction of porous media as a packaging of uniform spheres. Applying the two expressions for capillary
pressure in terms of the radii of the interface and in terms of the height of fluid column, we have for this system:
11/15/13 Chapter3
web.mst.edu/~numbere/cp/chapter 3.htm 11/26
From which,
In field units,
Unfortunately, and are impossible to measure in porous media and so are usually determined empirically from other measurements in theporous media. For this reason, it is more convenient to explicitly measure capillary pressure and use the equation below to calculate the height
of the fluid column.
Example 3.3
Using the drainage capillary pressure curve of the Venango Core (shown below). How many feet above the free water table is the water/oilcontact? (1 ft = 30.48 cm)
11/15/13 Chapter3
web.mst.edu/~numbere/cp/chapter 3.htm 12/26
Solution
From the figure, the capillary pressure at the water-oil contact can be read as 4 cm.
Since
Then,
=
3.3 Laboratory methods of measuring capillary pressure
Three generally accepted methods of measuring capillary pressure in the laboratory are:a) The Porous Diaphragm (or restored state) Methodb) The Centrifugal Method
c) The Mercury Injection MethodAll three tests are conducted on core plugs cut from reservoir whole core samples. Drilling fluids, coring fluids, coring procedure, core
handling and transportation, storage and experimental processes can alter the natural state of the core. Therefore, special precautions arenecessary to avoid altering the natural state of the core. If the natural state of saturation of the core had been altered, then it must be restored
to its natural state before conducting any capillary pressure tests. Fresh Core :
Samples from core taken with either water or oil-base muds that are preserved (with invaded fluids) and subsequently tested without cleaning
and drying are referred to as fresh cores.
Native State Cores : Samples from core recovered with lease crude or special oil base fluids known to have minimal influence on core wettability, and that are
tested as fresh samples, are referred to as Native State. These cores are in their native state (i.e. without invaded fluids). Such cores comingfrom above the transition zone should have the same quantity and distribution of water as in the reservoir. These samples are preferred for
water displacement tests.
11/15/13 Chapter3
web.mst.edu/~numbere/cp/chapter 3.htm 13/26
Restored Cores :
Core samples cleaned and dried prior to testing are referred to as restored cores. An advantage is that air permeability and porosity are
available to assist in sample selection. A disadvantage is that core wettability and spatial distribution of pore water may not match that in thereservoir.
The following precautions can be helpful in obtaining representative cores if the drilling conditions permit.1. Use oil-base drilling mud to minimize clay swelling
2. Use non-oxidized lease crude as a coring fluid.3. Suitable storage procedures include submersion under degassed water, and preservation with saran foil, and wax.
Refined oil versus crude oil
Refined oils are suitable for most tests, and are preferred when tests are at ambient conditions.Crude oils to be used in ambient tests should be sampled from non-water producing wells upstream from chemical or heater treaters.
Crude oils often precipitate paraffin or asphaltenes at ambient conditions, resulting in invalid test data.Reservoir condition test utilizing live crude oil at reservoir pressures and temperatures often overcome difficulties experienced with crude atambient conditions.
Reservoir fluid samples for special core tests may be recovered using bottom-hole sampling techniques, or recombined from separator gasand oil samples.
3.3.1 Centrifugal Method
1. Rotate at a fixed constant speed. The centrifugal force displaces some liquid, which can be read at the window using a strobe
light. Thus, the saturation can be obtained.2. The speed of rotation is converted to capillary pressure using appropriate equations. 3. Repeat for several speeds and plot capillary pressure with saturation.
3.3.2 Mercury Injection Method
1. Place core sample in a chamber and evacuate it.
2. Force mercury in under pressure. The amount of mercury injected divided by the pore volume is the non-wetting phasesaturation. The capillary pressure is the injection pressure.3. Continue for several pressures and plot the pressure against the mercury saturation.
Advantages: 1. Fast (minutes)
2. No threshold pressure limitation
11/15/13 Chapter3
web.mst.edu/~numbere/cp/chapter 3.htm 14/26
Disadvantage: 1. Can only be used for shaped cores.
3.3.3 Porous Diaphragm Method
1. Saturate both the core sample andthe diaphragm with the fluid to be displaced.
2. Place the core in the apparatus as shown3. Apply a level of pressure, wait for the core to reach static equilibrium.
The capillary pressure = height of liquid column + applied pressure
Production
4. Increase the pressure and repeat step (3)5. Plot capillary pressure versus saturation
Disadvantages: 1. Have to work within threshold pressure of the diaphragm 2. Takes too long to reach the equilibrium, therefore a complete curve takes from 10- 40 days
Mercury injection technique was developed to reduce this time.
3.4 Other methods
Dynamic method:
Time
Equilibrium
11/15/13 Chapter3
web.mst.edu/~numbere/cp/chapter 3.htm 15/26
1. Simultaneous steady flow of two fluids is established in the core2. Using special welted discs, the pressure of the two fluids in the core is measured. The difference = Capillary pressure
3. Change the rate of one fluid and the saturation changes
4. Plot versus saturation.
3.4.1 Field Method:
A long column of porous medium put in contact with a wetting fluid at its base and suspended in the earths gravitational field. It is left
to reach equilibrium. Samples are taken at different heights and the capillary pressure calculated using
Disadvantage: May take very long to reach equilibrium
3.4.2 Capillary Hysteresis
11/15/13 Chapter3
web.mst.edu/~numbere/cp/chapter 3.htm 16/26
3.4.3 Explanations for capillary hysteresis
1. The advancing and receding contact angles are different. If the contact angle during imbibition is the advancing contact angle, it differsfrom the contact angle drainage (receding). This may explain the phenomenon of hysteresis.
2. "Ink bottle effectFor porous media modelled as a bundle of tubes with varying diameters, a given capillary pressure exhibits a higher fluid saturation on the
drainage curve than on the imbibition curve.
11/15/13 Chapter3
web.mst.edu/~numbere/cp/chapter 3.htm 17/26
3.4.4 The effect of pore size distribution on capillary pressure curve
The more uniform the pore sizes, the flatter the transition zone of the capillary pressure curve.
3.4.5 Conversion of Laboratory Capillary Data to Reservoir Capillary Data
Water (brine) - oil capillary pressure data are difficult to measure in the laboratory. Generally, air - brine or air - mercury data are measured
instead and it becomes necessary to convert these data to equivalent oil - water data representative of reservoir fluids. If we denote or
as , and as the conversion equation can be derived as follows:
From , we obtain
From , we obtain
Assuming that the same porous medium applies in both laboratory and field, we equate the to obtain,
ignoring the contact angles,
An identical equation would be obtained by starting from the two equations:
Assuming the radii of curvature in the laboratory is the same as that in the reservoir, the RHS's can be equated and :
3.4.6 Calculating Average water saturation
11/15/13 Chapter3
web.mst.edu/~numbere/cp/chapter 3.htm 18/26
If a reservoir average capillary pressure curve (or even a laboratory curve) is available, it can be converted to a height versus water saturation
curve and used to calculate the average water saturation for any desired interval. One simply needs to put a new scale for the height on the y-axis of the Pc graph. The average water saturation between any two height intervals can be evaluated as the area enclosed between them
divided by the distance between the height intervals. An example illustrates the procedure.
Example 3.4
For a pay zone whose top and bottom are 45 ft and 25 ft from the free water table, use the laboratory Pc graph below to calculate the
average water saturation for this pay interval.
Solution to Example 3.4
First, convert the Pc lab to Pc res:
Next, convert Pc res to height above the free water table and plot on the right axis by putting
a new scale on the RHS for “h”. Its scale is 5.0 ´ the scale for Pc lab. This is shown below.
11/15/13 Chapter3
web.mst.edu/~numbere/cp/chapter 3.htm 19/26
Mark off the top (45 ft) and bottom (25 ft) on the h-axis.
Since the area in this case can be approximated by a single trapezoid, the shaded area
Therefore,
= 0.28
The area under more complex shaded areas can be calculated after sub-division into a number of trapezoids and applying the trapezoidal
rule.
3.5 Averaging Capillary Pressure Curves
Consider a reservoir cross-section from which four core samples are taken at different depth as shown below. Each core will generate its
own complete capillary pressure curve in the laboratory which can be converted to a reservoir capillary pressure curve. Thus four differentlaboratory capillary pressure curves are obtained as shown below. The question then arises:
How do we get a single curve to represent the reservoir?
The answer is to use the Leverett J-function
11/15/13 Chapter3
web.mst.edu/~numbere/cp/chapter 3.htm 20/26
3.5.1 Leverett J-function
The Leverett J-function is defined as:
where, = permeability = interfacial tension
= contact angle = porosityThe J-function has the effect of normalizing all curves to approach a single curve and is based on the assumption that the porous medium can
be modelled as a bundle of non-connecting capillaries (Slider pp 279-280). Obviously the more capillary bundle assumption deviates fromreality, the less effective the J-function correlation becomes. This correlation is not unique, but seems to work better when the rocks are
classed as to rock types, eg; limestone, dolomite, etc.
Given several capillary pressure curves, with corresponding values of permeability and porosity , the procedure for obtaining J-function curve is as follows:
a) Pick several values of from 0 to 1 and read the corresponding values of . There will be as many values as there are curves.
b) For each value, calculate J and plot versus . Repeat for all values.
c) Put your best correlation curve through the data.This J-Curve is now a master curve that can be used to represent that reservoir and in the absence of other data can be used for other
reservoirs of similar rock type. The graphs below, taken from (Amyx et.al.) shows the J-function curve for the Edwards formation showingclassification as to rock types.
11/15/13 Chapter3
web.mst.edu/~numbere/cp/chapter 3.htm 21/26
Fig. J-function correlation of capillary pressure data in the Edwards formation, Jourdanton Field. J-curve for (a) all cores; (b) limestonecores; (c) dolomite cores; (d) microgranular limestone cores; (e) coarse-grained limestone cores. (Source Amyx et.al.)
3.5.2 How to use the Leverett J-function to calculate Average Water Saturation
Values for average initial or connate water saturation are required in many petroleum engineering calculations. Examples are: (a) average
water saturation in a section of reservoir in order to fix effective fluid permeabilities, and (b) average water saturation in the whole
reservoir in order to fix the initial hydrocarbon volume in place, Under capillary equilibrium conditions, the water saturation of a particular piece, or sample of rock not depends on several factors. It has
been shown with certain limitations, that a properly determined Leverett J-function versus water saturation curve can be used to obtain anaverage water saturation from a number of capillary pressure curves. It is assumed that a Leverett J-function curve is available and applies to
the reservoir. The objective here is to show how to use the J-function to obtain the best possible estimate of average saturation. Recall thatthe J-function is defined as:
By expressing the term in terms of height and fluid densities the equivalent equation is:
It is important to note while applying this equation that its units are not important. Mixed units can be used without appropriate conversion
factors. It is only important to be sure to use the same units that went into determining the values of J making up the original plot. In otherwords, find out what units were used to calculate the J-function curve and stay consistent with those units whether they are mixed or not.
Note also that J=constant*h. Therefore, the shape of a J-function versus curve would be similar to that of a height versus curve. The
difference is a displacement by a factor equal to the constant. Thus, a curve can be converted to a height curve simply by adding a new y-
axis having its abscissa equal to the constant* .
3.5.2.1 Case 1: Permeability, Porosity, and Elevation are known for each sample
11/15/13 Chapter3
web.mst.edu/~numbere/cp/chapter 3.htm 22/26
This figure illustrates four reservoir samples having different values of permeability and porosity and located at different heights above a
datum. Assuming fluid properties are the same in all pieces, the J-function equation can be simplified to:
3.5.2.2 The correct method
The correct method of obtaining the average saturation, for the four pieces is to calculate J for each piece, determine the corresponding
water saturation, of each piece by using the J-curve and then taking the arithmetic average of the saturations with the equation:
Note that this procedure correctly takes into account the vertical position of the pieces and their corresponding permeability and porosity.
Less correct methods
These methods first calculate average values of and , substitute them into the J equation to get an average J value, and then read the
average water saturation from the J-function versus graph. The only advantage of these methods is that the amount of calculations isreduced. The resulting will always have error in it. How much error depends on the specific condition being calculated. The figure below
illustrates the concept behind using average values in order to obtain an average J value.
There are two ways:
Method (a): Calculate for each sample and obtain the arithmetic average for all four. Also, obtain the arithmetic average . It is
assumed that the average is located at the average height . The average J-function equation then becomes:
where,
11/15/13 Chapter3
web.mst.edu/~numbere/cp/chapter 3.htm 23/26
This is the easiest of the averaging methods to do.
Method (b): The geometric average permeability and porosity are used to get the average J-function:
= geometric mean permeability =
= geometric mean porosity =
Zero values of and are not permitted when evaluating the geometric averages. Because porosity values usually show very limited
range, the geometric average porosity, , can be replaced by the easier to calculate arithmetic average, , with little loss of accuracy.
Therefore, the form used by most engineers is
where, is the arithmetic average
3.5.2.3 Errors due to using average values of and
Standing(4) discusses the amount of error in introduced by using average values of and and states that the error depends on
several factors.One factor is the distribution of in a vertical sense. If the are distributed randomly, no error will be involved. On the other hand, if
high permeabilities predominate in one portion of the section and low permeabilities in another, some error will be introduced.
A second factor is the shape of the curve. Where log J is linear to , no error will result from geometric average . Where J is
linear with , some error will result.
A third factor is the range of permeability values. Little error is introduced when the range is small and more error is introduced when the
range is large. The best way to minimize errors of averaging is not to average. Use the correct method.
3.5.2.4 Case 2: Permeability and porosity are unknown as functions of elevation. Distance from (distance
from free-water table) is known
The petroleum engineer often needs to develop a value for average water saturation but does not have detailed information on permeabilityand porosity as a function of elevation. (Many wells are not core analyzed). However, he may know from results of pressure buildup tests
that the average permeability in the region of the wellbore is, say, 100 md. Also, he may know from well logs that an average porosity is, say
18%. With these average permeability and porosity values plus information on the distance to the appropriate datum and information
on fluid properties, he can make a reasonable calculation of the average water saturation.
11/15/13 Chapter3
web.mst.edu/~numbere/cp/chapter 3.htm 24/26
To illustrate the method of getting , consider the sketch above. At the wellbore location, the bottom and top of the formation are
and from the datum. For given values of , calculate . Shade the area enclosed by
and on the curve and calculate the average initial water saturation .
The simplest way of determining is by graphical integration. Thus, determine the area under the curve, divide this area by the value
and the result will give . That is:
Example 3.5
Example calculation of the use of Capillary Pressure Data to Obtain Average Water Saturation Using J-Function
It is desired to calculate the initial oil in place for an oil reservoir having a gas cap as illustrated below. There is no prior J-function curve
available and no well logs to give permeability, porosity, and saturation data with depth. All we have are old cores from storage.
The bulk volume of the oil zone is 1,000 acre-ft. The thickness of the oil zone is 20 ft. Four core samples were taken from the oil zone in the
middle of 5 ft. intervals. From laboratory measurements of porosity and permeability, the data are:
Interval depth Permeability Porosity
4,000 - 4,005 11.2 0.147
4,005 - 4,010 34.0 0.174
4,010 - 4,015 157.0 0.208
4,015 - 4,020 569.0 0.275
The free-water table is at a depth of 4030 ft. In addition to porosity and permeability, the capillary pressure for each sample was measured
using air displacing water in a centrifuge. These laboratory derived capillary pressure curves are shown below. The water/oil interfacialtension for this reservoir is estimated to be 28 dynes/cm, the reservoir (water/oil) wetting angle is 0.0. The air/water interfacial tension is 70
dynes/cm with a wetting angle of 0.0 also, . Calculate the average water saturation and the initial oil inplace.
11/15/13 Chapter3
web.mst.edu/~numbere/cp/chapter 3.htm 25/26
Solution
a) Convert the data to data and calculate the J-function curve using:
This has been calculated and plotted below.
b) Calculate the value of at each " " of each core and read the corresponding water saturation from the curve.
27.5 0.738 0.37
22.5 0.967 0.35
17.5 1.478 0.29
12.5 1.748 0.27
c) Obtain the arithmetic average water saturation.
The average water saturation
Using the Less correct method
11/15/13 Chapter3
web.mst.edu/~numbere/cp/chapter 3.htm 26/26
Therefore, by reading on the J-function curve at
Only and available
Suppose there are no cores, there are no well logs, an average is available from well tests, and can be estimated from correlations.
In this case, use the heights of the top and bottom of the pay zone from the free-water table to obtain and .
Similarly,
Plot these and find the average water saturation graphically.
Exercises 1. Give a possible reason why for a soap solution is about 40 dynes/cm and not about 70 dynes/cm as would be the case for fresh water.
2. Show that the expression derived for a tube is a special form of the general expression:
3. Given that and , would you expect a water/air interface or an oil/water interface to havea smaller contact angle assuming the same capillary pressure applies to both, in the same capillary tube.
4. Calculate the entry pressure for natural gas into a pore throat having the following sizes and shapes.a) A cylindrical shape pore throat of 0.0001 inch diameter
b) An elliptical shape pore throat of d1 = 0.0001 inches and d2 = 0.001 inches
c) An infinite horizontal fracture of fracture width = 0.0001 inches.
Use s = 35.2 dynes/cm, and q = 0.0
References
1. Clark, Norman J. "Elements of Petroleum Reservoirs" Henry L. Doherty Series, Society of Petroleum Engineers of AIME, Dallas, 1960.
2. Slider H.C., “Worldwide Practical Petroleum Reservoir Engineering Methods”, Penwell Books, 1983 3. Wilhite, G.P. : “Waterflooding”, SPE Textbook Series, Vol. 3, 1986.
4. Standing, M.B.: Lecture notes, Stanford University, 1977
5. Amyx, J. W., Bass, Jnr. D. M., Whiting, R. L. : Petroleum Reservoir Engineering, McGraw-Hill, 1960