16
OrCAD V16.3 新增功能 Date2010 / 01 / 07 Author林曉德 (Addi Lin) RevisionVersionV16.3 .備註: http://www.graser.com.tw OrCAD V16.3 增加使用者功能介面與操作方式,並加強了OrCAD PCB Editor 間的整合。 請參考以下OrCAD V16.3 各種新功能介紹。

capPN V163 NEW v5 - bbs.hwrf.com.cnbbs.hwrf.com.cn/downpcbe/OrCAD_V163_NEW-1489.pdf · OrCAD Capture V16.3 增進操作功能 z Auto Wire 自動連線功能 OrCAD V16.3 增加了自動連線功能,讓使用者連接電氣線的操作可以更加方便。

Embed Size (px)

Citation preview

OrCAD V16.3

Date 2010 / 01 / 07

Author (Addi Lin)

Revision

Version V16.3

:

http://www.graser.com.tw

OrCAD V16.3 OrCAD PCB

Editor

OrCAD V16.3

OrCAD Capture V16.3

Auto Wire

OrCAD V16.3

Associate Project Type

Capture

Design Navigation Improvements Net

Capture Off Page Connector

Capture Net Navigation Windows

OrCAD Capture V16.3 Color Wire

Capture Net Wire

Color Part

Capture

Embedded Images

OrCAD JPGBMPGIF

OLE object Support

Capture

Bezier Curves & Elliptical Arcs

Capture

PCB Editor 3D Footprint Viewer PCB Footprint 3D View

Capture Capture PCB Editor Footprint

User Define Pin Shapes Pin

Capture Part Pin Pin

Scripting Support Capture 16.3 scripting Capture

OrCAD Capture V16.3 PCB Locking Object on board & schematic

Board highlight Lock

Output Warnings Filter Netlist

NetlistNet namePart NamePin Name

constraints

PROPAGATION_DELAY

RATSNEST_SCHEDULE

RELATIVE_PROPAGATION_DELAY

DIFFERENTIAL_PAIR

NET_SPACING_TYPE

NET_PHYSICAL_TYPE

ELECTRICAL_CONSTRAINT_SET

RATSNEST_SCHEDULE

VOLTAGE

MIN_LINE_WIDTH

MIN_NECK_WIDTH

MATCHED_DELAY

Power Pin Enhancements Pin

Capture Assign Power Pins Power Pins

Power/Gnd NC

OrCAD Capture V16.3 DRC Electrical Rules

Capture physical electrical DRC

Check & Save Capture Check & Save ( Project Manager File Manu ) DRC

electrical

Fixed CCRS CCR ID Description

CCMPR00010116 Add Intersheet references doesn_t work in Complex Hierarch

CCMPR00011833 Junction not automatically placed when it should be.

CCMPR00013373 Select length of pin graphics

CCMPR00016310 Simple hierarchy; intersheet refs not refering to H- block

CCMPR00107219 Capture.ini switch is needed as a Registry entry like PSpic

CCMPR00134692 DDB_WARN: POWER_GROUP prop. not allowed wrongly coming

CCMPR00136260 Problem with netlisting the design in PSpice

CCMPR00145226 placing of pictures/graphics stored in jpg/jpeg format.

CCMPR00207620 Part in MISC2.OLB has incorrect pin out

CCMPR00226478 generate allegro netlist if hier block has no symbol

CCMPR00282027 Problem with Split Part and part graphics

CCMPR00299384 Part rotation resets the text to default position

CCMPR00380714 Ability to have Power pin set to Not Connect

CCMPR00382860 Display parts and nets in different colors

CCMPR00428261 spaces at end of pin name Could not create new pin inst library correction utility

CCMPR00461052 command line arguments for cis.exe

CCMPR00568273 documentation of variables in Capture.ini

CMPR00585904 Find a schematic page with help of nets

CCMPR00591847 Add Intersheet References does not work on simpleH design.

CCMPR00593076 Cannot redisplay an invisible OFFPAGE connectors name

CCMPR00607432 error code SPCODD-409 need to be documented

CCMPR00617784 Trying to open page 2 of the design Capture crashes

CCMPR00620303 Enhancement:Shortcut key for "Select Entire Net"

CCMPR00621054 Renamed net in netlist isolates components from the rest of the net.

CCMPR00623218 display pin names assosicated with a net in net Properties

CCMPR00623777 Place Wire not working correctly

CCMPR00627048 enahcnement to have new check option forDRC0042

CCMPR00627232 incorrect Rinf netlist creation in Capture

CCMPR00629008 enhancements for find command

CCMPR00631910 Capture hangs when working with search option

CCMPR00634749 Enhancement to change back the way arc was created earlier before orcad 16.2

CCMPR00636156 Unable to convert SDT Schematic to Capture Design

CCMPR00636585 Rotating components in Capture reset property position

CCMPR00637768 Enhancement to assign different colors to different net based on a unique property

CCMPR00641406 SPB 16.2 default print option changed to Inst mode

CCMPR00642095 Ability to disable the Pop-Up description of elements

CCMPR00642436 Save As symbol in part editor is not working fine

CCMPR00643330 path to allegro.cfg in opj file

CCMPR00650541 usage of PACK_IGNORE property

CCMPR00652200 How do I move the Find Window dialog to the right side with the Place Part dialog?

CCMPR00653784 Off-page connector name change to internal starting like "I12345555"

CCMPR00653902 Enhancement ?Print Option? setting in Capture.ini file

CCMPR00657131 Reference used in netlist formatter creates empty output and no warnings/errors

CCMPR00657180 Enhancement:Tooltip for DRC markers

CCMPR00657640 Zoom using Ctrl+Scroll mouse is different from Zoom using key " I "

CCMPR00663260 Enhancement: ALG0051 message should be more specific

CCMPR00666186 Enhancement FishEye functionality in Variant View Mode

CCMPR00668081 Capture Crash during Edit options

CCMPR00668799 Placing specific part crashs OrCAD Capture

CCMPR00672345 Remove tutorial for Orcad Layout or put it at the end in flowtut document

CCMPR00673410 search by net name is finding electrical

CCMPR00674555 If the DSN filename contains spaces; autobackup will not write any DBK files to

CCMPR00679960 Capture crashes from diff pair setup menu

CCMPR00687074 Part disappears when you open it

CCMPR00687354 Not able to create allegro netlist 228 ERROR(SPCODD-228): Cannot package

CCMPR00694139 Case difference of net and bus while generating FPGA netlist

CCMPR00696534 Pin Visibility check box doesnt work while creating part from spreedsheet editor

CCMPR00703905 Need Hot Fix number Info on Help >> About

CCMPR00706729 Import properties fails with ERROR [IMP0020]

CCMPR00710859 Unable to create Diff Pair from Autosetup

CCMPR00712299 Internal application error while creating new design

CCMPR00716212 PACK_SHORT property gives package error for visible POWER pins

CCMPR00722346 DRC checks for mismatches in labeling Net

OrCAD Capture CIS V16.3

CIS Bill of Materials

Relational Data Report

CIS relational CIS Bill of Materials

BOM relational relational

:

relational (related ):

Variant Not Stuffed

CIS Variant BOM Variant Not

Stiffed Qty 0 Displayed BOM 0

Fixed CCRS CCR ID Description

CCMPR00288640 Goto part on schematic inconsistent for multisection part

CCMPR00296826 Variant view displays library property

CCMPR00353212 Variant Name is not coming in Standard BOM

CCMPR00371580 revert to common not working

CCMPR00483351 goto function is not working in part manager

CCMPR00489866 Enchancement to get "set as Not present" parts into CIS BOM for Variant.

CCMPR00608701 CIS report current system date and time like in standard report

CCMPR00621072 Capture CIS Crash while configuring Database

CCMPR00639311 Lost functionality in PartManager

CCMPR00642422 After Copy parameters from one part to other in partmanager forgets previously highlighted line

CCMPR00644043 Need to use ctrl&Shift instead of C&S to select multiple parts in partmanager

CCMPR00644096 Copy&paste not working in partmanager

CCMPR00649166 Capture CIS crashes doing Place Database Part with non-admin User rights

CCMPR00650997 Incorrect Pin Shape in CIS Explorer Footprint window

CCMPR00651429 The bar pin is not correctly displayed between part olb & CIS Explorer >> Symbol viewer.

CCMPR00653051 Why hash (#) Character is appearing in CIS >> Standard >> BOM for hyperlink?

CMPR00666667 Relational Table View Browsing Issue

CCMPR00668785 Capture not displaying variant values for Uppercase Display props

CCMPR00674058 Incorrect Variant Report

CCMPR00678538 Why derive database does not transfer the? Schematic Part? property to CIS?

CCMPR00683146 export variant path apprears wrong in output folder while two DSN are open simultaneously

CCMPR00686338 ERROR #8012 Database Operation Failed with MS SQL database

CCMPR00687008 ERROR 8020 after removing Place Icon

CCMPR00710279 ERROR 8020# Place component operation failed.

CCMPR00714072 Error while linking database part