Capri Cable Gland

Embed Size (px)

Citation preview

  • 8/10/2019 Capri Cable Gland

    1/100

    and Accessories Solutions

    Global Cable Glands

  • 8/10/2019 Capri Cable Gland

    2/100

    One Cooper

    Cooper Industries is a premier global

    manufacturing company with eight

    operating divisions and thousands

    of well-known products that are used

    around the world every day. Cooper

    believes that you cant have a great

    company without great products.

    In order to provide its customers with thebest possible value, Cooper is dedicated

    to building quality electrical products and

    tools with global standards and

    a constant focus on innovation.

    The Companys high-quality products

    have earned leadership positions in

    the markets we serve and that leadership

    is sustained through unparalleled sales

    support and customer service.

  • 8/10/2019 Capri Cable Gland

    3/100

    Contents

    GLOBAL CABLE GLAND SOLUTIONS .... page 10

    EX ............................................................. page 28

    EX ACCESSORIES................................... page 58

    INDUSTRIAL ............................................ page 68

    INDUSTRIAL ACCESSORIES .................. page 78

    FIELD GUIDE ........................................... page 86

    3

  • 8/10/2019 Capri Cable Gland

    4/100

    Cooper Industries

    Cooper Industries is a multi-billion

    dollar global manufacturer of electrical

    components. Founded in 1833,

    Cooper has continued to focus on

    innovation, ethical business practices

    and meeting customer needs, helping it

    to become one of the most respected

    names in the world. Its seven divisions

    manufacture

    world-class products and brands

    that are market leaders in their field,

    such as Bussmann electrical and

    electronic fuses; Crouse-Hinds, CEAG

    and CAPRI explosion proof electrical

    equipment; Halo and Metalux lighting

    fixtures; and Kyle and Mcgraw-Edison

    power systems products.

    About us

    4 CAPRI

  • 8/10/2019 Capri Cable Gland

    5/100

    Cooper Capri

    Capri introduced its first items

    of electrical equipment in 1946.

    Continuous growth and development

    has since led us to our current position

    as one of the major suppliers of Cable

    Glands and Accessories for both

    hazardous and industrial areas all

    around the world.

    When it comes to protecting life

    and property theres no room to

    compromise. You need a partner that

    can support you with tried-and-tested

    products, global capabilities and

    local delivery. Thats where Cooper

    Capri comes in.

    Capri commits to surf on new trends

    and so to provide new solutions

    adapted to the Alternative Energies,

    Mining and Transportation markets

    requirements.

    The companys experienced engineers

    are always available to give technical

    advice on hazardous area problems,

    Certifications and Compliances

    requirements and procedures.

    5CAPRI

  • 8/10/2019 Capri Cable Gland

    6/100

    InnovationOur application-specific solutions arebuilt on more than 175 years in the

    business and thousands of patents.

    We understand the key factors to drive

    success in several markets:

    - Safety

    - Security

    - Quality

    - Efficiency

    - Intelligence- Lowest Total Cost Solutions

    We develop innovative products that

    help ensure each of these factors is

    built into our designs and solutions. In

    fact, Cooper is ranked #6 on Industrial

    Innovator. (Patent Boards August 2010

    Industrial Component Supplier Patent

    Scorecard)

    We continuously collaborate with cus-

    tomers to ensure that we offer the best

    product for your specific application

    whatever it is.

    With our balanced portfolio, we will

    maintain our vitality during market

    downturns which will allow us to conti-

    nue to drive innovative ideas for you.

    As Cooper Capri we are focused on

    voice of customer to determine our

    new innovative development. By this

    we have today a product offer with key

    recognized innovation by the market,

    such as our Armoured Cage System

    for easy inspectability and guarantee

    of secured connection, lower weight

    and highest density specifically desi-

    gned for transportation and storage

    optimization, a new sealing system to

    prevent the damage on inner sheath of

    the cable

    Capri is source of Creative

    Technologies. For us, Innovation

    does not just focus on technical

    but also on a perfect matching

    with environment our productsare moving around.

    6 CAPRI

  • 8/10/2019 Capri Cable Gland

    7/100

    Standing behind every major project

    is an experienced team. From the

    architects at the drawing board to the

    sites maintenance and evolutions not

    to mention the construction team on

    the ground, we work as a partner at all

    levels to deliver technical, integration

    and logistics support at every stage of

    a project.

    Cooper is committed to providing

    products and services on time,

    complete and to the highest level of

    quality. Cooper continues to invest

    to provide world class services and

    technology in order to become the

    easiest partner to do business with.

    Support

    With manufacturing and

    distribution locations worldwide

    and global technical sales and

    engineering teams,you can rely

    on our global expertise,

    locally delivered.

    7CAPRI

  • 8/10/2019 Capri Cable Gland

    8/100

    With an enviable reputation for quality and

    performance, Cooper Capri has become

    the partner of choice for many companiesoperating in demanding environments.

    Our expert approach to meeting the needs

    of our customers has helped us to play a

    pivotal role in many highly successful and

    prestigious projects around the world.

    The knowledge and expertise we leverage

    every day to help your operation run

    smoother and safer lies not in one mind but

    in thousands of Cooper employees.

    An experienced team of engineers,

    technicians heads the Design, Development

    and Innovation resource. We persist inmanufacturing and offering a complete

    range of innovative Cable Glands and

    Accessories which perfectly match

    all our customers requirements ; they

    more particularly appreciate the triple

    performance of our products : technical,

    installation and maintenance performances.

    Expertise

    8 CAPRI

  • 8/10/2019 Capri Cable Gland

    9/100

    CommittedCoopers commitment tothe environment

    As Cooper looks to the future, it is

    committed to minimizing the impact

    on the environment through thoughtful

    design, sourcing and manufacturing of

    its products.

    Energy efficiency

    Deliver significant energy savings.

    With the vast majority of its business

    focused around electrical products,

    Cooper is fully capable of delivering a

    wide range of energy-saving solutions

    across multiple product categories.

    Labour savings

    Generate labour savings through faster

    and more efficient installation Coopersproduct development efforts are

    consistently geared toward developing

    solutions that offer an innovative way of

    saving its customers either time, money

    or both.

    LEEDProducts and solutions that facilitate

    the construction of LEED-certified buil-

    dings (Leadership in Energy and Envi-

    ronmental Design) Cooper Industries

    offers a large portfolio of solutions that

    enable architects, engineers, contrac-

    tors and facility maintenance managers

    to create and maintain high-perfor-

    mance sustainabl building solutions.

    Eco-friendly

    Improve operating efficiencies

    while reducing the impact on the

    environment Cooper Industries has a

    formal, written environmental policy

    with the guiding principle to minimise

    its impact on the natural environment

    through assessment of emissions,

    effluents, resource use and waste.

    9CAPRI

  • 8/10/2019 Capri Cable Gland

    10/100

    GLOBAL CABLEGLAND SOLUTIONS

    10 CAPRI

  • 8/10/2019 Capri Cable Gland

    11/100

    Contents12 Oil & gas solutions

    14 Alternative energies

    16 Industrial and manufacturing

    18 Electrical equipment for potentially explosive atmospheres regulatory guide

    26 Main standards throughout the world

    11CAPRI

  • 8/10/2019 Capri Cable Gland

    12/100

    12 CAPRI

    INDUSTRIALAPPLICATION UNIVERSALREFERENCE STANDARDWATERPROOFAPPLICATIONS

    ADE 1F type glands, certified Flameproof

    Ex d, Increased Safety EX e & Restricted

    Breathing EX nR are suitable for use in

    Zone 1, Zone 2, in Gas Groups IIA, IIB and

    IIC, Zone 21 and Zone 22. They provide

    a controlled pull resistant with additional

    clamping and seal on the cable outer

    sheath, minimising damage to cables

    that exhibit cold flow characteristics.

    The gland maintains IP66 & IP68.

    ADE 4F type double compression glands,

    certified Flamproof Exd, Increased

    Safety Ex e & Restricted BreathingEx nR are suitable for use in Zone 1,

    Zone 2, in Gas Groups IIA, IIB and IIC,

    Zone 21 and Zone 22. They provide

    a controlled Ex d & IP seal on the cable

    inner sheath, an seal on the outer

    and a clamping sytem for wire (W),

    braid (X) or tape (Z) armoured cables.

    The gland maintains IP66 & IP68.

    ADE 4F are cold flow dedicated.

    ADE 6Ftype cable diaphragm gland,

    certified Flameproof Exd, Increased

    safety Exe and Restricted breathing

    Ex nR are suitable for use in Zone 1,

    Zone 2, in Gas Groups IIA, II B and IIC,

    Zone 21 and Zone 22. They provide a

    controlled Ex d and IP seal on the

    cable inner sheat and seal on the

    outer. The unique features include

    an innovative armour cage system for

    wire (w), braid (x) and (Z) armoured

    cables. The gland maintains IP66 and 68.

    Oil & Gas Solutions

    ADE 4FADE 1F ADE 6F

    Comprehensive product solutions for global

  • 8/10/2019 Capri Cable Gland

    13/100

    13CAPRI

    HIGHRESISTANCEANDEMC APPROVED SOLIDBARRIERSEALINGFORUNARMOURED

    ANDARMOUREDCABLE

    HIGHRESISTANCENYLON

    NEWCAP MS / CT type glands, certified

    Flameproof Ex d, Increased Safety EX e

    are suitable for use in Zone 1, Zone 2, Gas

    Groups IIA, IIB, IIC, Zone 21 and Zone 22.

    They are manufactured from Nickel plated

    Brass or Stainless Steel and provide a

    controlled pull resistant displacement

    seal on the cable outer sheath providing

    both Ex e & IP protection. The gland has

    been tested to IP66 & IP68. Available

    in metric thread with an o-ring on entry

    thread.

    ADE 1FC and ADE 6FC type glands,

    certified Flameproof Ex d, Increased

    Safety Ex e are suitable for use in Zone 1,

    Zone 2, Gas Groups IIA, IIB, IIC, Zone 21

    and Zone 22. They provide a compound

    barrier Ex d & IP seal on the cable inner

    cores, and an environmental seal on the

    outer sheath. The unique features include

    an innovative armour Cage System for

    wire (W), braid (X) and tape (Z) armoured

    cables. The gland maintains IP66 & IP68.

    ECDEP type glands, certified Increased

    Safety Ex e are suitable for use in Zone

    1, Zone 2, Gas Groups II, Zone 21 and

    Zone 22. They are manufactured from

    polyamide and provide a controlled pull

    resitant displacement seal and clamping

    on the cable outer sheath providing both

    Ex e & IP protection. The gland has been

    tested to IP66 & IP68. Avaible in black or

    blue for EX i application.

    ADE 1FCNEWCAP MS / CT ADE 6FC ECDEP

    oil & gas application

  • 8/10/2019 Capri Cable Gland

    14/100

    Suitable Products serving new energies solutions

    WINDTURBINE SOLAR

    With an average of two periods a year maintenance for wind turbines , working

    methods and appropriate equipment dedicated to the optimization of wind

    performance are important .

    Cable entries are major mechanical components in an environment where

    vibration and sealing are essential criteria for performance

    Solar energy is becoming more and

    more democratic around the world.

    For many years the installation of

    photovoltaic panels have accelerated

    programs by offering financial

    incentives especialy in Germany,

    Japan and also Australia.

    ECDEP

    14 CAPRI

    Alternative Energies

    NEWCAP CT ADE 4FADE 6F

  • 8/10/2019 Capri Cable Gland

    15/100

    HYDROPOWER

    Hydropower is the worlds largest renewable energy source. More than 16% of

    global electricity currently comes from water power which is yet has used 33%

    of its economic potential. Hydropower electricity market in emerging countries

    is growing particulary in India and China that have large reserves of natural

    water. The product range ADE is providing connection solutions in the large

    variety of cables used in those applications.

    In addition many emerging countries

    are increasingly consuming solar

    energy the main uses of these

    countries are for heating, cooling and

    water purification. UV Resistance ,

    resistance to changes in temperature

    are all selection criteria for cable

    entries

    ADE 1F ADE 1F

    15CAPRI

    ADE 4FADE 1Fwith integrated clamping

  • 8/10/2019 Capri Cable Gland

    16/100

    Complete range for industrial application

    TRANSPORT INDUSTRY

    ADE 1F

    16 CAPRI

    Project lead-times are becoming

    shorter with clients looking to achieve

    faster return on investments. By

    using products that are quick and

    easy to install Contractors can

    reduce construction lead-times and

    move on to the next project. Material

    characteristics and performance

    properties should be carefully

    considered as well as IP rating, UV

    stability and EMC screening.

    Products used within this segment are extremely technically demanding,

    requiring a comprehensive offer to meet a variety of applications and performance

    characteristics. Considerations regarding IP ratings, pull off characteristics,

    weight and corrosion resistance are all factors to consider.

    Typical Applications :

    - Railways

    - Signal sysytem

    -Tunnels

    Typical Product Solution :

    - ADE 1F / ADE 4F

    - NEWCAP MS / NEWCAP CT

    Approval :

    - LLOYDS . IECEx . CE

    ADE 4F NEWCAP CTNEWCAP MS

    Industrial and Manufacturing

  • 8/10/2019 Capri Cable Gland

    17/100

    MARINE

    ADE 1FADE 4F

    17CAPRI

    Typical Applications :

    - EMC manufacture and installation

    robots Machines

    - Welding Machines

    - CNC Machines

    - Factory automation

    -Typical Product Solution :

    - ADE 1F / ADE 4F

    - ECDEP

    - NEWCAP MS / NEWCAP CT

    Approval :

    - LLOYDS . IECEx . CE . ABS

    Within this sector, products are typically exposed to some of the harshest

    operational environments. Reliability is key with consideration to products

    specified and installed within this sector, due to their exposure to particular

    damaging effects from the wind, wave and salt spray conditions. Other factors

    such as operating temperature ranges and performance when exposed to

    vibration need to be considered.

    Typical Applications :

    - Ship/boat Engine Rooms

    - Leisure Boats & Cruisers

    - Ocean Going Craft- Ship and Dock Yards

    - Off Shore Oil Rigs

    Typical Product Solution :

    - ADE 1F / ADE 4F

    - ECDEP

    Approval :

    - LLOYDS . IECEx . CE . ABS

    ADE 4F ECDEP

  • 8/10/2019 Capri Cable Gland

    18/100

    18 CAPRI

    Electrical Equipment for Potentially Explosive Atmospheres

    DUST

    Starch (wheat)

    Wheat (bulk)

    Cocoa

    Rice

    Sugar

    Malt

    Paracetamol

    Polystyrene

    Sulphur

    Soap

    Milk powder

    Flour / wheat

    Soya (flour)

    Corn starch

    Cellulose

    Aluminium

    Acetylsalicylic acid

    Ascorbic acid

    Asphalt

    Cork

    DANGEROUS SUBSTANCESThere are two main families: flammable gases, vapours and liquids on the one hand, dust in layers or clouds on the other hand.

    The following table gives a non-exhaustive list of the most common substances:

    GASES AND VAPOURS

    Methane

    Acetone

    Petrol

    DieselAcetylene

    Propane

    Xylene

    Styrene

    Propanol

    Benzene

    Hydrogen

    Town gas

    Ammonia

    MethanolHexane

    Fuel oil

    Ethyl nitrite

    Ethyl acetate

    Ether

    Naphthalene

    Ethane

    Butane

    Carbon bisulfide

    KerosineCarbon monoxide

    Nitromethane

    Ethyl alcohol

    Limonene

    Butadiene

    Pentane

    Complete list available from the CNPP (French national safety and protection centre) and the INRS (French national research and safety institute).

    Explosion risks

    In the chemicals, oil and agrofood industries many

    dangerous substances in the forms of gas, smoke,

    liquid, powder or dust are used or released during the

    manufacture, processing or storage of such products as:

    gases, hydrocarbons, plastics, varnishes, paints, drugs,

    powders, cereals, cosmetics, glues, etc

    What conditions produce explosions?

    When flammable substances are mixed with oxygen in the

    ambient air in certain proportions, only an ignition source

    is required to produce an explosion. This ignition source

    can be: a naked flame, a mechanical or electrical spark,static electricity, or simply a hot surface.

    To prevent explosions when electrical energy is used, it

    is essential to use ATEX electrical equipment which has

    been specially designed for this kind of hazardous envi-

    ronment.

    Flammablesubstances

    (gases, vapours,dusts etc.)

    Oxygen in theair

    Explosion

    Ignition source

    An explosion can occur

    when three elements are present :

  • 8/10/2019 Capri Cable Gland

    19/100

    19CAPRI

    Regulatory Guide

    Hazardous zonesApplication of the ATEX Directive 99/92/EC requires users to assess the explosion risks of their plants and to produce a classification of

    the hazardous zones. There are three Zone types according to the likelihood of a potentially explosive atmosphere being present, and two

    separate applications according to the nature of the mixture (gases or dusts).

    These areas must take into account any external parameters (ventilation, openings, heating etc.) that can modify the scope of the zones.

    The illustration below gives an example of classification into hazardous zones of an unloading station for a flammable liquid. The principle is

    the same for dust, only the name changes and becomes Zone 20, 21, 22. Beyond Zones 2 or 22, an explosive mixture is no longer likely to

    occur; this is outside the classified zone and standard industrial equipment can be used.

    Remarks :

    Equipment certified for Zone 0 can also be used in Zones 1 and 2.

    Equipment certified for Zone 22 cannot be used in Zones 20 and 21.

    Zone 0 (inside tank) and Zone 20 (inside silo) are zones where there is no fixed electrical equipment (apart from measurement sensors).

    Equipment certified for Zone 21 cannot be used in Zone 1.

    GAS certified ATEX equipment (especially e increased safety equipment) is protected by means of its enclosure and by

    each internal component.

    However, DUST certified ATEX equipment is only protected by means of its external enclosure. Nevertheless a lot of

    equipment has double GAS and DUST certification which can be used in both of these two zone types.

    CONTINUOUS PRESENCEINTERMITTENT PRESENCE

    (NORMAL OPERATING CONDITIONS)

    OCCASIONAL PRESENCE

    (ABNORMAL OPERATING CONDITIONS)

    Zone 0 (gases) Zone 1 (gases) Zone 2 (gases)

    Zone 20 (dusts) Zone 21 (dusts) Zone 22 (dusts)

    Zone 0

    Zone 2

    Zone 1

    Zone 0

  • 8/10/2019 Capri Cable Gland

    20/100

    20 CAPRI

    Protection methods

    Several protection methods are recognized by the IEC (International Electrotechnical Commission) and the CENELEC

    (European Committee for Electrotechnical Standardization). Each protection method is symbolized by a letter given on the

    equipments ATEX label.

    Since 1 July 2006, standards in the series EN50014 to EN50028 have been replaced by those of series EN60079 and

    EN61241 listed in the table below.

    Several protection methods can be used on the same equipment. In this case the relevant symbols appear one after the other (e.g.

    Ex de ib IICT4).

    The most common protection methods for ATEX lighting and ATEX low voltage equipment are flameproof enclosure d and

    increased safety e.

    Flameproof enclosure d

    Any components that create electrical arcs are housed

    in an enclosure which must have three functions :

    contain an explosion from within, with no permanent deformation.

    ensure that no flame can be transmitted to the outside atmosphere.

    at every exterior point have temperatures less than the auto-ignition temperature

    of the gases present.

    Standards define the gap i and point length (L) values according to the gas group. Flameproof enclosures are generally

    made of cast aluminium or alloy (minimum IP54) and require regular rigorous maintenance (greasing of the seals and tighte-

    ning torques).

    Increased safety e

    Each component is designed not to create sparks or excessive heating; therefore:

    air gaps are larger

    terminals are specific (auto-loosening impossible)

    the enclosure is at least IP54, made of antistatic and shock resistant (7Nm) material.

    Increased safety enclosures are generally made of polyamide or reinforced polyester. Conductor connection must be rigorous(stripping and tightening) and instructions on use voltages and currents must be complied with. The temperature class takes

    into account the hottest point of the equipment (see page 23).

    L

    i

    ELECTRICAL EQUIPMENT PROTECTION METHODS

    IEC/EN standards Symbol Principle

    Gases Dusts Gases Dusts

    60079-0 61241-0 - - General rules60079-1 61241-1 d tD Flameproof enclosure

    60079-2 61241-2 px/py/pz pD Purged and pressurized

    60079-5 q - Powder filling

    60079-6 o - Oil immersion

    60079-7 e - Increased safety

    60079-11 61241-11 la/lb/lc laD/lbD Intrinsic safety

    60079-15 nAnLnRnC

    - Non-sparkingEnergy limited

    Vapour-proof housingEnclosed break

    60079-18 61241-18 ma/mb maD/mbD Encapsulation

    Electrical Equipment for Potentially Explosive Atmospheres

  • 8/10/2019 Capri Cable Gland

    21/100

    21CAPRI

    ATEX directive

    Directive 94/9/EC (ATEX 100A)

    From 1 July 2003, electrical equipment used in potentially explosive atmospheres within the European Union must comply with this

    Directive and bear the standard ATEX marking.

    The Directive defines essential safety requirements for manufacturers and requires classification of equipment into groups and

    categories, while identifying gas and dusts aspects.

    Directive 99/92/EC

    This Directive requires users to employ a number of measures aimed at ensuring the safety of workers, including :the assessment of explosion hazards in plants

    the classification of different hazardous zones (see page 13) and signalling :

    the holding of a document on protection against explosions

    the implementation of technical and organizational safety measures

    compliance with selection criteria for electrical equipment according to the table below :

    Equipment

    categories

    Flammable

    substances

    Protection

    levelsProtection, faults

    Equipment group I

    (mines)

    M1Methane

    DustsVery high

    2 means of protection or 2

    separate faults

    M2

    Methane

    Dusts

    High1 means of protection

    Normal operation

    Equipment group II

    (surface)

    1Gases, vapours,

    mists, dustsVery high

    2 means of protection or 2

    separate faults

    2Gases, vapours,

    mists, dustsHigh

    1 means of protection

    Ordinary and frequent failure

    3Gases, vapours,

    mists, dustsNormal Level of protection required

    The entire COOPER offer presented in this catalogue is intended for surface industries (Group II).

    EX marking

    EX

    Regulatory Guide

    POUSSIERES Zones Equipment category

    Gases

    0 :Continuous presence 1G

    1 :Intermittent presence 2G or 1G

    2 :Occasional presence 3G, 2G or 1G

    Dusts

    20 :Continuous presence 1D

    21 :Intermittent presence 2D or 1D

    22 :Occasional presence 3D, 2D or 1D

    1 : Name of the manufacturer

    2 : CE marking

    3 : N of the notified body responsible for monitoring

    4 : Type of atmosphere dust and gas

    5 : Equipment category

    6 : Equipment group surface industries

    7 : Atex marking

    8 : Year of manufacturing

    9 : Gases marking10 : Type of equipment and references

    11 : N of CEtype examination certificate

    12 : UL and CSA marking

    1 12 7 2 3 11 9

    10 8 6 5 4

  • 8/10/2019 Capri Cable Gland

    22/100

    Gas and vapour classification

    Group II (surface industries) has three subdivisions IIA, IIB and IIC defined according to the maximum experimental safe gap

    (MESG) for Exd enclosures or according to the minimum ignition energy (MIE) for intrinsic safety equipment. Most COOPER

    products presented in this catalogue are designed for group IIC (the most dangerous) and therefore can be used practically

    anywhere. However note that for certain flameproof products (spotlights, boxes) we generally propose two separate solu-

    tions for groups IIB and IIC.

    It is better only to use ExdIIC solutions in the presence of hydrogen, acetylene, carbon bisulfide or ethyl nitrate, because of

    the high cost of this equipment. ExdIIB solutions are sufficient for all other gas or vapour types.

    Equipment using only the Exe increased safety protection method does not have the A, B or C subdivision because it can be

    used whatever gas is present.

    TEMPERATURE CLASSESEach gas has a specific auto-ignition temperature. When this temperature is reached, the gas flames spontaneously, with

    no spark or electrical arc. This auto-ignition temperature must therefore be considered as a limit not to be reached, whether

    or not in normal operation. The standards define six temperature classes (T1 to T6) corresponding to six maximum surface

    temperatures (450C to 85C).

    Temperature class T6 is the most severe.

    e hane (

    Hydrogen 560 (T1)

    hylene (T2)

    ce ylene (

    Kerosine 210 (T3)

    hyl e her (

    arbon disulfide 95(T6)

    T6 85

    e.g. on a flameproof lamp, a

    T6 temperature class marking

    means that the lamps surface

    temperature will always be less

    than or equal to 85C.

    Each gas has a specific auto-ignition temperature.

    e.g. kerosine ignites spontaneously

    from 210C. If you want to install a

    lamp near a kerosine loading station,

    the lamp must be classed at least T3

    so as not to cause an explosion (a lamp

    classed T4, T5 or T6 would also suit).

    22 CAPRI

    Electrical Equipment for Potentially Explosive Atmospheres

    Selection process- according to IEC 60079-14a) cable glands in compliance with IEC 60079-1 and certified as part of the equipment when tested with a sample of the

    particular type of cable

    b) where a cable, in compliance with 9.3.1(a) is substantially compact; a flameproof cable gland, in compliance with IEC

    60079-1, may be utilized, providing this incorporates a sealing ring and is selected in accordance with Figure 2.

    Compliance with Figure 1 is not necessary if the cable gland complies with IEC 60079-1 and has been tested with a sample

    os specific cable to repeated ignitions ot the flammable gas inside an enclose and shows no ignition outside the enclosure.

    * Internal sources of ignition

    include sparks or equipement

    temperatures occuring in normaloperation which can cause

    ignition. An enclosure containing

    terminals only or an indirect

    entry enclosure (see 10.4.1) is

    considered not to constitute an

    internal an internal source of

    ignition.

    * The term volume is defined in IEC

    60079-1.

    Start

    Does this enclosure

    contain an internal

    source of ignition ?a)

    Is the volume b) of the

    enclosure greater than

    2 dm3?

    Does the hazardous

    gas require IIC

    apparatus ?

    Apply 10.4.2 d)or e)

    Is the area of

    installation zone 1?

    Use a suitable

    flameproof cable entry

    device with a sealing

    ring

    YES

    YES

    YES

    YES

    NO

    NO

    NO

    NO

  • 8/10/2019 Capri Cable Gland

    23/100

    Dusts classificationEach type of dust was subject to detailed studies to obtain their flammability characteristics (INRS brochures/Silos guide etc.).

    Dusts are singular because their auto-ignition temperatures differ according to whether the dust is in a cloud or a layer. Since

    many other parameters can modify these auto-ignition values (particle size, humidity, ambient temperature etc.), a calculation

    including a safety factor must be performed in each case.

    In the case of dust in a cloud, the maximum surface temperature of the equipment must not exceed two thirds of the

    ignition temperature, in degrees Celsius, of the air/dust mixture (T1).

    In the case of dust in layers less than 5 mm, a safety factor of 75C must be deducted from the layer auto-ignition

    temperature, in degrees Celsius, of the relevant dust (T2).

    The choice of equipment must be done by taking the worst result.

    The table below gives the results obtained for the most common dusts :

    Dust cloud Dust layer 5 mm Maximum surface

    temperature to use for

    equipment selection

    Auto-ignition T (T1)

    Equipment surface

    T

    (2/3 of T1)

    Auto-ignition T (T2)

    Equipment surface

    T

    (T2-75C)

    Bulk wheat 500C 333C 220C 145C 145C

    Flour 440C 293C 440C 365C 293C

    Cocoa 510C 340C 240C 165C 165C

    Starch (wheat) 400C 267C 380C 305C 267C

    Milk powder 490C 327C 200C 125C 125CCork 460C 307C 210C 135C 135C

    Soya (flour) 550C 367C 340C 265C 265C

    Malt (barley) 400C 267C 250C 175C 175C

    Rice 510C 340C 450C 375C 340C

    Cellulose 480C 320C 270C 195C 195C

    Sulphur 190C 127C 220C 145C 127C

    Polyethylene 450C 300C 380C 305C 300C

    Charcoal 530C 354C 180C 105C 105C

    Sugar 370C 247C 400C 325C 247C

    23CAPRI

    Regulatory Guide

  • 8/10/2019 Capri Cable Gland

    24/100

    24 CAPRI

    Indexes of protectionThe index of protection IP uses two digits to

    define the degree of protection secured by

    the equipments outer enclosure.

    The first digit corresponds to protection

    against solid objects.

    The second digit corresponds to protection

    against water or liquid.

    Electrical equipment for potentially explosive

    atmospheres generally provides indexes

    of protection much higher than standard

    industrial equipment.

    Most of our products are classed IP65/IP66,

    or even IP67 and can thus be used in very

    severe environments.

    IP tests

    0 No special protection

    1

    50 mm

    Protection against solidobjects larger than 50 mm

    2

    12,5 mm

    Protection against solid

    objects larger than 12.5 mm

    3

    2,5 mm

    Protection against solidobjects larger than 2.5 mm(tools, screws)

    4

    1 mm

    Protection against solidobjects larger than 1 mm(thin tools etc.)

    5Protection against dust (noharmful deposits)

    6Complete protectionagainst dust

    IP tests

    0 No special protection

    1Protection against waterdripping/falling vertically

    2Protection against watersprayed at an angle up to15from the vertical

    3Protection against spraywater any direction up to 60from the vertical

    4Protection against spraywater from all directions

    5Protection against lowpressure water jets from anydirection

    6Total protection againsthigh pressure jets from alldirections

    7Protection against temporaryimmersion

    8Protection againstpermanent immersion inspecified conditions

    1stdigit :

    Protection against solid objects

    2nddigit :

    Protection against liquids

    Indexes of protection of electrical equipment enclosuresaccording to standards iec 60529 and en 60529

    Electrical Equipment for Potentially Explosive Atmospheres

  • 8/10/2019 Capri Cable Gland

    25/100

    25CAPRI

    Chemical resistance of plasticsATEX electrical equipment with increased safety is often manufactured in high quality plastics, specially selected and tested

    for use in extremely severe environments (chemicals, petrochemicals, offshore, deserts etc.). These materials have been used

    for many years and have proven reliability. The main uses are :

    polyamide: junction boxes, control centres, portable lamps

    polycarbonate: translucent bowls for lamps or glasses

    polyester: distribution panels, boxes, control centres

    The table below gives data supplied by plastics manufacturers on their resistance to a series of chemicals.

    Substance Polyamide Polyester Polycarbonate

    Acetone + + -

    Ethyl alcohol (up to 30%) 0 + 0,96%

    Ethyl glycol 0 + +

    Ammonia (23%) + +10% -

    Benzene + + +

    Benzole (23%) + + -

    Boric acid 3% + + +

    Butane + + +

    Chlorite bleach solution 0 +

    Chloric gas (wet) 0 + -

    Chlorinated lime 0 + +

    Chromic acid (10%) - + +

    Cyclohexane + + +Diesel + + +

    Kerosine + + +

    Acetic acid (up to 25%) 0 + +10C

    Formaldehyde + + +

    Glycol + + +

    Glycerine + + +

    Uric acid (up to 20%) + + +

    Fuel oil + + +

    Machine oil 0 + +

    Sea water + + +

    Methyl alcohol 0 + 0

    Lactic acid, conc. 20% + + +Mineral oil + +

    Sodium chloride 0 + +

    Sodium base liquor (20-25C) + +5% -

    Petroleum + + -

    Phosphoric acid, conc. - + +

    Soapy water (23C) + + +

    Sulphuric acid 5-30% and 70% 0 + +

    Sulfur dioxide, dry (23C) + + 0

    Premium petrol (up to 60C) + + -

    Turpentine (23C) + + -

    Tartaric acid + up to 10%0 + +Citric acid up to 32% + + +

    Explanation of the symbols : + = stable 0 = limited stability - = unstable

    Regulatory Guide

  • 8/10/2019 Capri Cable Gland

    26/100

    Lloydsregister

    DNVDet Norsk Veritas

    ABSAmerican Bureau

    ipping IEC Ex CEC NEC

    Lloyds register Det NorskV ritasAmerican Bureau

    of hipping

    International

    Electronical

    C mmission relating

    to Equipment for

    use in Explosive

    atmospheres

    C nadian Electrical

    de

    (Products

    pproved by UL,

    FM, CSA)

    National Electrical

    Code

    (Products approved

    by UL, FM, A)

    Aim

    nsure an a equate sa ety an re a ty t rougoffshore classification, thus providing assurance

    t at requ rements a own n app ca e ru es

    and regulations are met during all phases of the

    asset s esgn, construct on an operaton.

    FacilitatingInternationaltrade in Electrical

    equipmentintended foruse in explosiveatmospheresby eliminatingthe need formultiple nationalcertification.

    nsure a ety n azar ous reas or :

    Flammable Gases Vapors orqu s ass

    Combustible Dusts : Class II

    Ignitable Fiber and Flyings : Class III

    Localisation INTERNATIONAL INTERNATIONAL CANADA USA

    Application arine O Shore

    Main standards throughout the world

    26 CAPRI

    C US

    LISTED

    UL C US

    LISTED

    UL

    MARINE

  • 8/10/2019 Capri Cable Gland

    27/100

    ATEXMenbers

    ATEXAffi liates CEPEL NEPSI GOST CCoE KAZAK

    ATmospheres

    EXplosibles

    Entro de

    Pesquisas de

    Energia eLectricas

    N tional Explosion

    Protection Safety

    Instrumentation

    GOsudarstvennyy

    T ndart

    Chief Controller of

    Explosives

    nsure a ety n expos ves tmosp eres or

    Electrical Equipment intended for use :

    n m nes suscept e o re amp roup

    In places with an explosive gas other than mines Group II

    In place with an explosive dust atmosphere Group III

    EUROPEAN

    COUNTRIES

    AFFLIATES CHINA RUSSIA KAZAKHSTAN

    On-Shore & O-Shore Ex Equipment requirements

    27CAPRI

    CEPEL Ex

    NEPSI

  • 8/10/2019 Capri Cable Gland

    28/100

    28 CAPRI

  • 8/10/2019 Capri Cable Gland

    29/100

    Contents

    30 Selection guide for cable gland

    32 ADE 1F34 ADE 1F

    35 ADE 1F kit

    36 ADE 1F with integrated clamping

    37 ADE 1FC

    38 ADE 1FLC

    40 ADE 4F

    42 ADE 4F

    43 ADE 4F kit

    44 ADE 6F

    46 ADE 6F

    47 ADE 6F KIT48 ADE 6FC

    49 ADE 6FLC

    50 NEWCAP

    52 NEWCAP MS-e

    53 NEWCAP CT-e

    54 ECDEP

    56 ECDEP Ex-e

    57 ECDEP Ex-i

    58 Certified accessories

    29CAPRI

  • 8/10/2019 Capri Cable Gland

    30/100

    30 CAPRI

    Selection Guide for Cable Gland

    Technology of the Cooper cable glands

    Barrier type Elastomer ring Elastomer cone

    RESIN

    (epoxy or diferent)

    SEALING WITH

    COMPRESSED RING

    DEFORMATION

    CONE

    DIAPHRAGM

    Cable typeProtection

    type

    Unarmoured

    Flameproof

    and

    increased

    safety

    Increased

    safety

    Unarmoured or

    braid shielded

    Increased

    safety

    SWA, SWB, STA,

    braided marine

    shipboard and lead

    sheath cable( with addition of earthing

    washer )

    Flameproof

    and

    increased

    safety

    SWA, SWB, STA

    braided marine

    shipboard

    Industrial

  • 8/10/2019 Capri Cable Gland

    31/100

    31CAPRI

    CEPEL ExNEPSI

    C US

    LISTED

    UL C US

    LISTED

    UL

    MARINE

    EM

    Cpro

    of

    Dd

    iCEM

    ADE 1F p.34

    ADE 1FWITH INTEGRATED

    CLAMPING

    p.36

    ADE 1FC p.37

    ADE 1FLC p.38

    ECDEP p.56

    NEWCAP

    MS-ep.52

    NEWCAP

    CT-ep.53

    ADE 4F p.42

    ADE 6F p.46

    ADE 6FC p.48

    ADE 6FLC p.49

    ADE 4i p.77

  • 8/10/2019 Capri Cable Gland

    32/100

    >For unarmoured cable

    >IP68

    > Compliance

    >EX 60079-0 2009 Performance

    >Nickel plated brass andStainless steel

    >Optional : external clamping

    >Optional : aluminium and

    bronze raw material

    ADE 1F

    1 F U N C T I O N : S E A L I N G

    ADE 1F

    page 34

    ADE 1FC

    page 37

    ADE 1F

    With integrated clampingpage 36

    32 CAPRI

  • 8/10/2019 Capri Cable Gland

    33/100

    OPTIONAL EXTERNAL CLAMPING 316 L stainless steel made ( digit 9 )

    IP68 Silicone option for extreme temperature

    KIT SOLUTIONSAvailable with lock nut,

    fiber washer and additionnal accessories

    ADE 1FLC

    page 38

    33CAPRI

  • 8/10/2019 Capri Cable Gland

    34/100

    ADE 1F

    Features :

    Standard nickel-plated brass material for superior corrosion resistance.

    Neoprene seal certified from -40c to +60C.

    Available with silicone seal certified from -70c to +140C. Related accessories, see pages 58 to 67.

    Caution: A cable clamping must be realized within a range of 300 mm from theextremity of the cable gland. A Capri clamping module can be used, see page 61.

    Type of Cable Gland With elastomeric seal

    Cable type Non-armoured cable or armoured cable (does

    not terminate the armour)

    Certifications and Compliances LCIE 97 ATEX 6008X II 2 GD - ExdIIC/ExeII/ExtD

    IECEx LCI 05.0004X - ExdllC/Exell/ExtD

    cULus Listed for Class I Zone 2 AEx e II/Ex e II

    cULus Marine Listed for Class I Zone 1 AEx e II /Ex e II NEMA 4X and IP68 with sealing washer

    CEPEL-EX-558/05X

    GOST-R POCC FR.B03126

    NEPSI N GYJ071336U & GYJ071337U

    DNV N E-10892

    ABS approbation :n 10-HS 577243-PDA / P1836754-X

    Lloyds

    GLANDSIZE

    ENTRY THREAD SIZE THREADLENGTH EISO / (NPT)

    OUTER SHEATHL

    HEXAGONE

    ISO Reference NPT Reference A BMin Max

    4 12* CAP816404 1/4* CAP818404 15 (12) 4,5 8 20 15 15

    4 16* CAP816594 3/8* CAP818594 15 (12) 4,5 8,5 20 15 19

    5 16* CAP816504 3/8* CAP818504 15 (12) 7 12 22 19 19

    4 20 CAP816674 1/2 CAP818674 15 (22,2) 4,5 8.5 20 15 24

    5 20 CAP816694 1/2 CAP818694 15 (22,2) 7 12 22 19 24

    6 20 CAP816604 1/2 CAP818604 15 (22,2) 10 16 (15,5) 25 24 24

    5 25 CAP816774 3/4 CAP818774 15 (22,2) 7 12 22 19 30

    6 25 CAP816794 3/4 CAP818794 15 (22,2) 10 16 25 24 30

    7 25 CAP816704 3/4 CAP818704 15 (22,2) 13,5 20,5 (21) 27 30 30

    7 32 CAP816894 1 CAP818894 15 (27,3) 13,5 21 27 30 41

    8 32 CAP816804 1 CAP818804 15 (27,3) 18 27,5 34 41 41

    8 40 CAP816994 1 - 1/4 CAP818994 15 (28) 18 27,5 34 41 48

    9 40 CAP816904 1 - 1/4 CAP818904 15 (28) 23 34 36 48 48

    9 50 CAP817094 1 - 1/2 CAP819094 15 (28,5) 23 34 36 48 55

    10 50 CAP817004 1 - 1/2 CAP819004 15 (28,5) 29 41 39 55 55

    11 63 CAP817294 2 CAP819294 17 (29,2) 35 48 41 64 64

    12 63 CAP817204 2 CAP819204 17 (29,2) 42 56 43 72 72

    12 75 CAP817394 2 - 1/2 CAP819494 18 (42,5) 42 56 43 72 85

    13 75 CAP817304 2 - 1/2 CAP819404 18 (42,5) 50 65 49 85 85

    14 90 CAP817594 3 CAP819594 22 (44) 58 74 56 95 95

    15 90 CAP817504 3 CAP819504 22 (44) 66 78 61 110 11016 110 CAP817794 3 - 1/2 CAP819604 22 (45,2) 75 93 (92) 62 120 120

    OPTIONS (replace the last digit with option number) :9 Stainless steel (316L)

    8 Bronze

    7 Aluminum

    5 Silicone sealing ring for temperatures from -70C

    to +220C

    EXAMPLE :

    CAP81640 4

    Gland Type Options

    * Uncertified UL // sizes n4 and 5, no UL marine

    CEPEL ExNEPSI

    C US

    LISTED

    UL C US

    LISTED

    UL

    MARINE

    34 CAPRI

  • 8/10/2019 Capri Cable Gland

    35/100

    Features :

    Cable gland specifications, see page 34.

    Standard nickel-plated brass material for superior corrosion resistance.

    Neoprene seal certified from -40c to +60C.

    Available with silicone seal certified from -70c to +140C. Related accessories, see pages 58 to 67.

    Caution: A cable clamping must be realized within a range of 300 mm from theextremity of the cable gland. A Capri clamping module can be used, see page 61.

    Type of Cable Gland With elastomeric seal

    Cable typeNon-armoured cable

    or armoured cable (does not terminate the armour)

    GLANDSIZE

    ENTRY THREAD SIZE THREADLENGTH EISO / (NPT)

    OUTER SHEATHL

    HEXAGONE

    ISO Reference NPT Reference A BMin Max

    4 12* CAP816404K_ 1/4* CAP818404K_ 15 (12.0) 4.5 8 20 15 15

    4 16* CAP816594K_ 3/8* CAP818594K_ 15 (12.0) 4.5 8.5 20 15 19

    5 16* CAP816504K_ 3/8* CAP818504K_ 15 (12.0) 7 12 22 19 19

    4 20 CAP816674K_ 1/2 CAP818674K_ 15 (22.2) 4.5 8.5 20 15 24

    5 20 CAP816694K_ 1/2 CAP818694K_ 15 (22.2) 7 12 22 19 24

    6 20 CAP816604K_ 1/2 CAP818604K_ 15 (22.2) 10 16.0 (15.5) 25 24 24

    5 25 CAP816774K_ 3/4 CAP818774K_ 15 (22.2) 7 12 22 19 30

    6 25 CAP816794K_ 3/4 CAP818794K_ 15 (22.2) 10 16 25 24 30

    7 25 CAP816704K_ 3/4 CAP818704K_ 15 (22.2) 13.5 20.5 (21.0) 27 30 30

    7 32 CAP816894K_ 1 CAP818894K_ 15 (27.3) 13.5 21 27 30 41

    8 32 CAP816804K_ 1 CAP818804K_ 15 (27.3) 18 27.5 34 41 41

    8 40 CAP816994K_ 1-1/4 CAP818994K_ 15 (28.0) 18 27.5 34 41 48

    9 40 CAP816904K_ 1-1/4 CAP818904K_ 15 (28.0) 23 34 36 48 48

    9 50 CAP817094K_ 1-1/2 CAP819094K_ 15 (28.5) 23 34 36 48 55

    10 50 CAP817004K_ 1-1/2 CAP819004K_ 15 (28.5) 29 41 39 55 55

    11 63 CAP817294K_ 2 CAP819294K_ 17 (29.2) 35 48 41 64 64

    12 63 CAP817204K_ 2 CAP819204K_ 17 (29.2) 42 56 43 72 72

    12 75 CAP817394K_ 2-1/2 CAP819494K_ 18 (42.5) 42 56 43 72 85

    13 75 CAP817304K_ 2-1/2 CAP819404K_ 18 (42.5) 50 65 49 85 85

    14 90 CAP817594K_ 3 CAP819594K_ 22 (44.0) 58 74 56 95 95

    15 90 CAP817504K_ 3 CAP819504K_ 22 (44.0) 66 78 61 110 11016 110 CAP817794K_ 3-1/2 CAP819604K_ 22 (45.2) 75 93 (92) 62 120 120

    * Uncertified UL // sizes n4 and 5, no UL marine

    ADE 1F KIT

    OptionsGland Type

    CAP816404 K1

    EXAMPLE :9 Stainless steel (316L)

    8 Bronze

    7 Aluminum

    5 Silicone sealing ring for temperatures from -70C

    to +220C

    K1 : delivered with locknut and fiber gasket

    K2 : delivered with locknut, fiber gasket,earth tag and shroud

    OPTIONS (replace the last digit with option number) :

    35CAPRI

  • 8/10/2019 Capri Cable Gland

    36/100

    ADE 1F with integrated clamping

    Features :

    Standard nickel-plated brass material for superior corrosion resistance.

    Neoprene seal certified from -40c to +60C.

    Available with silicone seal certified from -70c to +140C.

    Integrated clamping ensures the cable mooring.

    Related accessories, see pages 58 to 67.

    Type of Cable Gland With elastomeric seal

    Cable type

    Non-armoured cableor armoured cable (does not terminate the armour)

    Certifications and Compliances LCIE 97 ATEX 6008X II 2 GD - ExdIIC/ExeII/ExtD

    LCIE 97 ATEX 6008X II 2 GD - ExdIIC/ExeII/ExtD

    cULus Listed for Class I Zone 2 AEx e II/Ex e II

    cULus Marine Listed for Class I Zone 1 AEx e II /Ex e II

    NEMA 4X and IP68 with sealing washer

    CEPEL-EX-558/05X

    GOST-R POCC FR.B03126

    NEPSI N GYJ071336U & GYJ071337U

    DNV N E-10892

    ABS approbation :n 10-HS 577243-PDA / P1836754-X

    Lloyds

    GLANDSIZE

    ENTRY THREAD SIZE THREADLENGTH EISO / (NPT)

    OUTER SHEATHL

    HEXAGONE

    ISO Reference NPT Reference A BMin Max

    4 16* CAP026594 / / 15 4,5 8,5 20 20 19

    5 16* CAP026504 / / 15 7 12 22 24 19

    4 20 CAP026674 1/2 CAP028674 15 (22,2) 4,5 8,5 20 20 24

    5 20 CAP026694 1/2 CAP028694 15 (22,2) 7 12 22 24 24

    6 20 CAP026604 1/2 CAP028604 15 (22,2) 10 16 (15,5) 25 27 24

    5 25 CAP026774 3/4 CAP028774 15 (22,2) 7 12 22 24 30

    6 25 CAP026794 3/4 CAP028794 15 (22,2) 10 16 25 27 30

    7 25 CAP026704 3/4 CAP028704 15 (22,2) 13,5 20,5 (21) 27 32 30

    7 32 CAP026894 / / 15 (27,3) 13,5 21 27 32 36

    8 32 CAP026804 / / 15 (27,3) 18 27,5 34 41 41

    8 40 CAP026994 / / 15 (28) 18 27,5 34 41 44

    9 40 CAP026904 / / 15 (28) 23 34 36 48 48

    OPTIONS (replace the last digit with option number)9 Stainless steel (316L)

    8 Bronze

    7 Aluminum

    5 Silicone sealing ring for temperatures from -70C

    to +220C

    EXAMPLE :

    CAP02659 4

    Gland Type Options

    * Uncertified UL // sizes n4 and 5, no UL marine

    CEPEL ExNEPSI

    C US

    LISTED

    UL C US

    LISTED

    UL

    MARINE

    36 CAPRI

  • 8/10/2019 Capri Cable Gland

    37/100

    ADE 1FC

    Features :

    Standard nickel-plated brass material for superior corrosion resistance.

    Neoprene seal and resin certified from -60c to +80C.

    Provides a flameproof and weatherproof seal on outer sheath of cable

    Provides explosionproof on wires Deluge boot provides enhanced protection from water ingress

    Red cap nut : Compound inside

    Fully inspectable flameproof seal

    Related accessories: see pages 58 to 67.

    Caution: A cable clamping must be realized within a range of 300 mm from theextremity of the cable gland. A Capri clamping module can be used, see page 61.

    Type of Cable Gland With compound, barrier type.

    Cable type Non-armoured cable

    Certifications and Compliances

    LCIE 97 ATEX 6008X II GD ExdIIC/ExeII/ExtD IECEx LCI 05.0004X ExcellC/Excell/ExtD

    cULus Listed for Class I Zone 2 AEx e II/Ex e II

    cULus Marine Listed for Class I Zone 2 AEx e II /Ex e II

    NEMA 4X and IP68 with sealing washer

    CEPEL EX-558/05X

    GOST-R POCC FR.B03126

    NEPSI N GYJ071336U & GYJ071337U

    DNV N E-10892

    ABS approbation :n 10-HS 577243-PDA / P1836754-X

    Lloyds

    GLANDSIZE

    ENTRY THREAD SIZE THREADLENGTH

    EISO / (NPT)

    CABLE

    L

    HEXAGONE

    ISO Reference NPT ReferenceOUTER SHEATH CONDUCTOR

    A BMin Max Max number Max

    4 16 CAP019594 3/8" CAP011594 15 (12) 6 12 6,5 7,5 6 36 15 19

    4 20 CAP019674 1/2" CAP011674 15 (22,2) 6 12 6,5 7,5 6 36 15 24

    5 20 CAP019694 1/2" CAP011694 15 (22,2) 8.5 16 9,5 11 6 42 19 24

    6 20 CAP019604 1/2" CAP011604 15 (22,2) 12 21 12 14,5 10 48 24 30

    6 25 CAP019794 3/4" CAP011794 15 (22,5) 12 21 12 14,5 10 48 24 30

    7 25 CAP019704 3/4" CAP011704 15 (22,5) 16 27,5 17 19,5 41 58 30 41

    7 32 CAP019894 1 CAP011894 15 (27,3) 16 27,5 17 19,5 41 58 30 41

    8 32 CAP019804 1 CAP011804 15 (27,3) 21 34 23 28 42 70 41 48

    8 40 CAP019994 11/4 CAP011994 15 (28) 21 34 23 28 42 70 41 48

    9 40 CAP019904 11/4 CAP011904 15 (28) 27 41 29 33 60 79 48 55

    9 50 CAP019094 11/2 CAP011094 16 (28,5) 27 41 29 33 60 79 48 55

    10 50 CAP019004 2 CAP011004 16 (29,2) 33 48 36,5 41 80 88 55 64

    11 63 CAP019294 2" CAP011294 17 (29,2) 40 56 43 48 100 98 64 72

    12 63 CAP019274 2" CAP011204 17 (29,2) 46 65 50 56 100 103 72 85

    12 / / 2"1/2 CAP011494 / (42,5) 46 65 50 56 100 103 72 85

    13 75 CAP019304 2"1/2 CAP011404 18 (42,5) 54 74 59 65 120 111 85 95

    13 / / 3" CAP012504 / (44) 54 74 59 65 120 111 85 95

    14 90 CAP010594 3" CAP012574 22 (44) 63 83 66 73 140 120 95 110

    14 / / 3"1/2 CAP012604 / (45,2) 63 83 66 73 140 120 95 110

    15 90 CAP010504 3" CAP012594 22 (44) 72 93 75 82 140 125 110 120

    15 / / 3"1/2 CAP012694 / (45,2) 72 93 75 82 140 125 110 120

    16 110 CAP010794 4" CAP012704 22 (46,5) 85 107 85 92 200 128 120 135

    OptionsGland Type

    CAP96959 4

    EXAMPLE:

    9 Stainless steel (316L)

    8 Bronze

    7 Aluminum

    OPTIONS (replace the last digit with option number) :

    CEPEL C US

    LISTED

    UL C US

    LISTED

    UL

    MARINE

    37CAPRI

  • 8/10/2019 Capri Cable Gland

    38/100

    ADE 1FLC

    Features :

    Standard nickel-plated brass material for superior corrosion resistance.

    Neoprene seal and resin certified from -60c to +80C. Provides flameproof seal on the wires and the outer sheath of the unarmoured

    cables.

    Red cap nut : compound inside

    Related accessories : see pages 58 to 67.

    Caution: A cable clamping must be realized within a range of 300 mm from theextremity of the cable gland. A Capri clamping module can be used, see page 61.

    GLANDSIZE

    ENTRY THREAD SIZE THREADLENGTH

    EISO / (NPT)

    CABLE

    L

    HEXAGONE

    CONDISO Reference NPT Reference

    OUTER SHEATH CONDUCTORA B

    Min Max Max number Max

    4 16 CAP519594 3/8 CAP511594 15 (12) 4 7,5 6,5 5 X 1,5 36 15 19 40

    4 20 CAP519674 1/2 CAP511674 15 (22,2) 4 7,5 6,5 5 X 1,5 36 15 24 40

    5 20 CAP519694 1/2 CAP511694 15 (22,2) 6,5 11 9,5 5 X 2,5 42 19 24 40

    6 20 CAP519604 1/2 CAP511604 15 (22,2) 9 14,5 12 8 X 2,5 48 24 30 40

    6 25 CAP519794 3/4 CAP511794 15 (22,5) 9 14,5 12 8 X 2,5 48 24 30 40

    7 25 CAP519704 3/4 CAP511704 15 (22,5) 12 19,5 17 12 X 2,5 58 30 41 30

    OptionsGland Type

    CAP51959 4EXAMPLE:

    9 Stainless steel (316L)

    8 Bronze

    7 Aluminum

    OPTIONS (replace the last digit with option number) :

    Type of Cable Gland With liquid resin, barrier type

    Cable type Non-armoured cable

    Certifications and Compliances LCIE 97 ATEX 6008X II GD ExdIIC/ExeII/ExtD

    IECEx LCI 05.0004X

    NEMA 4X et IP68 avec joint plat

    CEPEL cepel-EX-558/05X

    NEPSI NGYJ071336U & GYJ071337U

    DNV N E-10892 GOST-R : POCC FR Bo2011

    ABS approbation :n 10-HS 577243-PDA / P 1836754-X

    Lloyds

    CEPEL Ex

    NEPSI

    38 CAPRI

  • 8/10/2019 Capri Cable Gland

    39/100

    Time-tested, quality cable glandsfrom Cooper Crouse-Hinds offeravailable on request :

    Complete termination solution for cableapplications meeting North American

    standards

    Ease of cable termination providing

    labor and time management productivity

    Explosion-protected connections

    contributing to safe operation in harsh

    hazardous environments

    Delivery meeting installation and project

    coordination schedules

    Please refer to :www.cooperindustries.com

    North AmericanStandards range

    39CAPRI

  • 8/10/2019 Capri Cable Gland

    40/100

    ADE 4F

    4 F U N C T I O N S : D O U B L E

    >For armoured cable

    >IP68

    > Compliance

    >EX 60079-0 2009 Performance

    >Nickel plated brass andstainless steel

    >Optional : aluminium and

    bronze raw material

    >Optional : external clamping

    and lead sheat cable contact

    washer

    ADE 4F

    page 42

    40 CAPRI

  • 8/10/2019 Capri Cable Gland

    41/100

    HIGH DENSITY DESIGNEasy handling and transportation

    Storage optimization

    IP68 Silicone option for extreme temperature

    SWA / CWB / STA cable compliance

    S T E P S E A L I N G , E A R T H I N G , A R M O U R C L A M P I N G

    KIT SOLUTIONSAvailable with lock nut,

    fiber washer and additionnal accessories

    Available with insulated adaptor

    41CAPRI

  • 8/10/2019 Capri Cable Gland

    42/100

  • 8/10/2019 Capri Cable Gland

    43/100

    GLANDSIZE

    ENTRY THREAD SIZE LENGTHE

    ISO / (NPT)

    CABLEMAX ARMOUR

    THICKNESS L

    HEXAGONE

    ISO Reference NPT ReferenceINNER SHEATH OUTER SHEATH

    A BMin Max Min M ax

    5 12* CAP846404K_ 1/4* CAP848404K_ 15 (12) 4,5 8 7 12 0,9 36 19 19

    5 16* CAP846594K_ 3/8* CAP848594K_ 15 (12) 4,5 8,5 7 12 0,9 36 19 19

    6 16* CAP846504K_ 3/8* CAP848504K_ 15 (12) 7 12 10 16 1,25 42 24 24

    5 20 CAP846674K_ 1/2 CAP848674K_ 15 (22,2) 4,5 8.5 7 12 0,9 36 19 24

    6 20 CAP846694K_ 1/2 CAP848694K_ 15 (22,2) 7 12 10 16 1,25 42 24 24

    7 20 CAP846604K_ 1/2 CAP848604K_ 15 (22,2) 10 16 (15,5) 13,5 21 1,25 46 30 30

    6 25 CAP846774K_ 3/4 CAP848774K_ 15 (22,2) 7 12 10 16 1,25 42 19 30

    7 25 CAP846794K_ 3/4 CAP848794K_ 15 (22,2) 10 16 (15,5) 13,5 21 1,25 46 24 30

    8 25 CAP846704K_ 3/4 CAP848704K_ 15 (22,2) 13,5 20,5 18 27,5 1,6 56 30 41

    8 32 CAP846894K_ 1 CAP848894K_ 15 (27,3) 13,5 21 18 27,5 1,6 56 41 41

    9 32 CAP846804K_ 1 CAP848804K_ 15 (27,3) 18 27,5 23 34 1,6 63 41 48

    9 40 CAP846994K_ 1-1/4 CAP848994K_ 15 (28) 18 27,5 23 34 1,6 63 48 48

    10 40 CAP846904K_ 1-1/4 CAP848904K_ 15 (28) 23 34 29 41 2 68 48 55

    10 50 CAP847094K_ 1-1/2 CAP849094K_ 16 (28,5) 23 34 29 41 2 68 55 55

    11 50 CAP847004K_ 1-1/2 CAP849004K_ 16 (28,5) 29 41 35 48 2,5 74 55 64

    12 63 CAP847294K_ 2 CAP849294K_ 17 (29,2) 35 48 42 56 2,5 77 64 72

    13 63 CAP847204K_ 2 CAP849204K_ 17 (29,2) 42 53 50 65 2,5 85 72 85

    13 75 CAP847394K_ 2-1/2 CAP849494K_ 18 (42,5) 42 56 50 65 2,5 85 85 85

    14 75 CAP847304K_ 2-1/2 CAP849404K_ 18 (42,5) 50 62,5 58 74 2,5 92 85 95

    15 90 CAP847594K_ 3 CAP849594K_ 22 (44) 58 74 66 83 3,15 104 95 110

    16 90 CAP847504K_ 3 CAP849504K_ 22 (44) 66 78 75 93 3,15 108 110 120

    16 90 CAP847574K_ 3-1/2 CAP849604K_ 22 (45,2) 66 82 93 107 3,15 108 120 120

    17 110 CAP847794K_ 4 CAP849704K_ 22 (46,5) 75 92 93 107 3,15 115 135 135

    ADE 4F KIT

    Features :

    Cable gland Certifications and Compliances,see page 42.

    Standard nickel-plated brass material for superior corrosion resistance.

    Neoprene seal certified from -40c to +60C.

    Available with silicone seal certified from -70c to +140C.

    Suitable for Cold Flow cable.

    Related accessories, see pages 58 to 67.

    Armour clamping and bonding with no reversible components for easy installation,minimizing error.

    Caution: with non-armoured cable, braided cable or armoured cable without armourconnecting, a cable clamping must be realized within a range of 300 mm from theextremity of the cable gland. A Capri clamping module can be used, see page 61.

    Type of Cable Gland With elastomeric seal

    Cable type Steel wire armoured cable

    Steel wire braided cable

    Steel tape armoured cable

    Braided marine shipboard cable

    Lead sheathed cable (with addition of earthing washer)

    OptionsGland Type

    EXAMPLE:9 Stainless steel (316L)

    8 Bronze

    7 Aluminum

    5 Silicone sealing ring for temperatures from -70C

    to +220C

    OPTIONS (replace the last digit with option number) :

    CAP8464 4 K1

    K1 : delivered with locknut and fiber gasket

    K2 : delivered with locknut,fiber gasket, earth tag and shroud

    K4 : Delivered with lock nut , insulated adaptor eath tagand 2 fiber washer

    43CAPRI

  • 8/10/2019 Capri Cable Gland

    44/100

    ADE 6F

    6 F U N C T I O N S : D O U B L E C L A M P I N G

    >For armoured cable

    >IP68

    > Compliance

    >EX 60079-0 2009 Performance

    >Nickel plated brass standard

    finishing

    >Optional : stainless steel,

    aluminium and bronze raw

    material

    >Optional : external clamping

    BARRIER or ELASTOMER

    technology ADE 6Fpage 46 ADE 6FCpage 48 ADE 6FLCpage 49

    44 CAPRI

  • 8/10/2019 Capri Cable Gland

    45/100

    DELUGE BOOT Integrated deluge seal, no removing in case of vibrations

    6F sealing diaphragm system to prevent damages on inner sheat of cable

    ARMOUR CAGE SYSTEMExclusive clamping armour cage system

    SWA / CWB / SWB / STA cable compliance

    Easy assembly with armour stop system

    Unique assembly direction

    BARRIER OR ELASTOMER TECHNOLOGYAvailable in kits with additionnal accessories

    Liquid for project and solid barrier solutions

    S T E P S E A L I N G , E A R T H I N G , A R M O U R ,A R M O U R N T E R L O C K I N G A N D D E L U G E B O O T

    45CAPRI

  • 8/10/2019 Capri Cable Gland

    46/100

    ADE 6F

    Features :

    Standard nickel-plated brass material for superior corrosion resistance.

    Neoprene seal certified from -60c to +100C.

    Diaphragm seal for cold flow cable. Deluge boot providing enhanced protection from water ingress.

    Related accessories, see pages 58 to 67.

    Armour clamping and bonding with no reversible components for easyinstallation, minimizing error.

    Caution: with non-armoured cable, braided cable or armoured cable without armourconnecting, a cable clamping must be realized within a range of 300 mm from theextremity of the cable gland. A Capri clamping module can be used, see page 61.

    Type of Cable Gland With elastomeric diaphragm

    Cable type Steel tape armoured cable

    Steel wire armoured cable

    Steel wire braided cable

    Braided marine shipboard cable

    Certifications and Compliances LCIE 97 ATEX 6008X II 2 GD - ExdIIC/ExeII/ExtD

    IECEx LCI 05.0004X - ExdllC/Exell/ExtD

    cULus Listed for Class I Zone 2 AEx e II/Ex e II

    cULus Marine Listed for Class I Zone 1 AEx e II /Ex e II

    NEMA 4X and IP68 with sealing washer CEPEL-EX-558/05X

    GOST-R POCC FR.B03126

    NEPSI N GYJ071336U & GYJ071337U

    DNV N E-10892

    ABS approbation :n 10-HS 577243-PDA / P1836754-X

    Lloyds

    GLANDSIZE

    ENTRY THREAD SIZE THREADLENGTH

    E

    ISO / (NPT)

    CABLEMAX

    ARMOURTHICKNESS

    L

    HEXAGONE

    ISO Reference NPT ReferenceINNER SHEATH OUTER SHEATH

    A B

    Min Max Min Max5 16 CAP965594 3/8" CAP967594 15 (12) 3 7,5 6 12 0,9 46 19 19

    5 20 CAP965674 1/2" CAP967674 15 (22,2) 3 7,5 6 12 0,9 46 19 24

    6 20 CAP965694 1/2" CAP967694 15 (22,2) 6,5 11 8.5 16 1,25 53 24 24

    7 20 CAP965604 1/2" CAP967604 15 (22,2) 9 14,5 12 21 1,25 59 30 30

    7 25 CAP965794 3/4" CAP967794 15 (22,5) 9 14,5 12 21 1,25 59 30 30

    8 25 CAP965704 3/4" CAP967704 15 (22,5) 12 19,5 16 27,5 1,6 74,5 41 41

    8 32 CAP965894 1 CAP967894 15 (27,3) 12 19,5 16 27,5 1,6 74,5 41 41

    9 32 CAP965804 1 CAP967804 15 (27,3) 17,5 26 21 34 1,6 83,5 48 48

    9 40 CAP965994 11/4 CAP967994 15 (28) 17,5 26 21 34 1,6 83,5 48 48

    10 40 CAP965904 11/4 CAP967904 15 (28) 23 33 27 41 2 92 55 55

    10 50 CAP966094 11/2 CAP968094 16 (28,5) 23 33 27 41 2 92 55 55

    11 50 CAP966004 2 CAP962894 16 (29,2) 27 41 33 48 2.5 104 64 64

    * Uncertified UL // sizes n4 and 5, no UL marine

    For larger sizes, please refer to ADE 4F on page 42.

    OptionsGland Type

    EXAMPLE:

    9 Stainless steel (316L)

    8 Bronze7 Aluminum

    OPTIONS (replace the last digit with option number) :

    CAP96594 4

    CEPEL ExNEPSI

    C US

    LISTED

    UL C US

    LISTED

    UL

    MARINE

    46 CAPRI

  • 8/10/2019 Capri Cable Gland

    47/100

    ADE 6F KIT

    Features :

    Cable gland specifications see page 46.

    Standard nickel plated brass material for superior corosion resistance.

    Neoprene seal certified from -60C to +100C. Related accessories, see pages 58 to 67.

    Caution: with non-armoured cable, braided cable or armoured cable without armourconnecting, a cable clamping must be realized within a range of 300 mm from theextremity of the cable gland. A Capri clamping module can be used, see page 61.

    Type of Cable Gland With elastomeric diaphragm

    Cable type Steel tape armoured cable

    Steel wire armoured cable

    Steel wire braided cable

    Braided marine shipboard cable

    Certifications and Compliances LCIE 97 ATEX 6008X II 2 GD - ExdIIC/ExeII/ExtD

    IECEx LCI 05.0004X - ExdllC/Exell/ExtD

    cULus Listed for Class I Zone 2 AEx e II/Ex e II

    cULus Marine Listed for Class I Zone 1 AEx e II /Ex e II

    NEMA 4X and IP68 with sealing washer CEPEL-EX-558/05X

    GOST-R POCC FR.B03126

    NEPSI N GYJ071336U & GYJ071337U

    DNV N E-10892

    ABS approbation :n 10-HS 577243-PDA / P1836754-X

    Lloyds

    GLANDSIZE

    ENTRY THREAD SIZE THREADLENGTH

    E

    ISO / (NPT)

    CABLEMAX

    ARMOURTHICKNESS

    L

    HEXAGONE

    ISO Reference NPT ReferenceINNER SHEATH OUTER SHEATH

    A B

    Min Max Min Max5 16 CAP965594K_ 3/8" CAP967594K_ 15 (12) 3 7,5 6 12 0,9 46 19 19

    5 20 CAP965674K_ 1/2" CAP967674K_ 15 (22,2) 3 7,5 6 12 0,9 46 19 24

    6 20 CAP965694K_ 1/2" CAP967694K_ 15 (22,2) 6,5 11 8.5 16 1,25 53 24 24

    7 20 CAP965604K_ 1/2" CAP967604K_ 15 (22,2) 9 14,5 12 21 1,25 59 30 30

    7 25 CAP965794K_ 3/4" CAP967794K_ 15 (22,5) 9 14,5 12 21 1,25 59 30 30

    8 25 CAP965704K_ 3/4" CAP967704K_ 15 (22,5) 12 19,5 16 27,5 1,6 74.5 41 41

    8 32 CAP965894K_ 1 CAP967894K_ 15 (27,3) 12 19,5 16 27,5 1,6 74.5 41 41

    9 32 CAP965804K_ 1 CAP967804K_ 15 (27,3) 17,5 26 21 34 1,6 83.5 48 48

    9 40 CAP965994K_ 11/4 CAP967994K_ 15 (28) 17,5 26 21 34 1,6 83.5 48 48

    10 40 CAP965904K_ 11/4 CAP967904K_ 15 (28) 23 33 27 41 2 92 55 55

    10 50 CAP966094K_ 11/2 CAP968094K_ 16 (28,5) 23 33 27 41 2 92 55 55

    11 50 CAP966004K_ 2 CAP962894K_ 16 (29,2) 27 41 33 48 2,5 104 64 64

    * Uncertified UL // sizes n4 and 5, no UL marine

    For larger sizes, please refer to ADE 4F on page 42.

    OptionsGland Type

    EXAMPLE:

    9 Stainless steel (316L)

    8 Bronze

    7 Aluminum

    OPTIONS (replace the last digit with option number) :

    CAP96594 4 K4

    K1 : delivered with locknut and fiber gasketK2 : delivered with locknut,

    fiber gasket, earth tag and shroud

    K4 : Delivered with lock nut , insulated adaptor eath tagand 2 fiber washer

    47CAPRI

  • 8/10/2019 Capri Cable Gland

    48/100

    ADE 6FC

    GLANDSIZE

    ENTRY THREAD SIZE THREADLENGTH

    EISO / (NPT)

    OUTERSHEATH MAX

    ARMOURTHICKNESS

    CONDUCTORSL

    HEXAGONE

    ISO Reference NPT Reference Min Max Max

    over cores Max

    inner sheathMax No.Og cores

    A B

    5 16 CAP969594 3/8" CAP971594 15 (12) 6 12 0.9 6.5 7.5 6 46 19 19

    5 20 CAP969674 1/2" CAP971674 15 (12,2) 6 12 0.9 6.5 7.5 6 46 19 24

    6 20 CAP969694 1/2" CAP971694 15 (22,2) 8.5 16 1.25 9.5 11 6 53 24 24

    7 20 CAP969604 1/2" CAP971604 15 (22,2) 12 21 1.25 12 14.5 10 59 30 30

    7 25 CAP969794 3/4" CAP971794 15 (22,5) 12 21 1.25 12 14.5 10 59 30 30

    8 25 CAP969704 3/4" CAP971704 15 (22,5) 16 .5 1.6 17 19.5 21 74.5 41 41

    8 32 CAP969894 1 CAP971894 15 (27,3) 16 .5 1.6 17 19.5 21 74.5 41 41

    9 32 CAP969804 1 CAP971804 15 (27,3) 21 34 1.6 23 28 42 83.5 48 48

    9 40 CAP969994 11/4 CAP971994 15 (28) 21 34 1.6 23 28 42 83.5 48 48

    10 40 CAP969904 11/4 CAP971904 15 (28) 27 41 2 29 33 60 92 55 55

    10 50 CAP970094 11/2 CAP972094 16 (28,5) 27 41 2 29 33 60 92 55 55

    11 50 CAP970004 2 CAP972294 16 (29,2) 33 48 2.5 36.5 41 80 104 64 64

    12 63 CAP970294 2" CAP972274 17 (29,2) 40 56 2,5 43 48 100 108 72 72

    13 63 CAP970204 2" CAP972204 17 (29,2) 46 65 2,5 50 56 100 118 85 85

    13 75 CAP970394 2"1/2 CAP972494 / (42,5) 46 65 2,5 50 56 100 118 85 85

    14 75 CAP970304 2"1/2 CAP972404 18 (42,5) 54 74 2,5 59 65 120 124 95 95

    14 / / 3" CAP972574 / (44) 54 74 2,5 59 65 120 124 95 95

    15 90 CAP970594 3" CAP972594 22 (44) 63 83 3,15 66 73 140 133 110 110

    15 / / 3"1/2 CAP972694 22 (45,2) 63 83 3,15 66 73 140 133 110 110

    16 90 CAP970504 3" CAP972504 22 (44) 72 93 3,15 75 82 140 137 120 120

    16 / / 3"1/2 CAP972604 / (45,2) 72 93 3,15 75 82 140 137 120 120

    17 110 CAP970794 4" CAP972704 22 (46,5) 85 107 3,15 85 92 200 142 135 135

    Features :

    Standard nickel-plated brass material for superior corrosion resistance.

    Neoprene seal and resin certified from -60c to +80C.

    Provides flameproof seal on the wires and the inner sheath of the armoured cables.

    Provides the sealing on the outer sheath of the armoured cables.

    Red cap nut : compound inside.

    Deluge boot provides enhanced protection from water ingress.

    Fully inspectable sealing and armour clamping and crimping including deluge boot. Related accessories: see pages 58 to 67.

    Armour clamping and bonding with no reversible components for easyinstallation, minimizing error.

    Caution: with non-armoured cable, braided cable or armoured cable without armourfastening, a cable clamping must be realized within a range of 300 mm from theextremity of the cable gland. A Capri clamping module can be used, see page 61.

    OptionsGland Type

    CAP96959 4

    EXAMPLE:

    9 Stainless steel (316L)

    8 Bronze

    7 Aluminum

    OPTIONS (replace the last digit with option number) :

    Type of Cable Gland With resin

    Cable type Steel tape armoured cable

    Steel wire armoured cable

    Steel wire braided cable

    Braided marine shipboard cable

    Certifications and Compliances ATEX LCIE 97 ATEX 6008X Exd IIC/Exe II/

    Ex tD/Ex II 2 GD

    IECEx LCI 05.0004X

    cULus listed for Class I Zone 2 AEx e II/Ex e II cULus Marine listed for Class I Zone 1 AEx e II Ex e II

    NEMA 4X et IP68 with sealing washer

    CEPEL-EX-558/05X

    GOST-R : POCC FR Bo2011

    NEPSI N GYJ071336U & GYJ071337U

    ABS approbation :n 10-HS 577243-PDA / P 1836754-X

    DNV N E-10892

    Lloyds

    C US

    LISTED

    UL C US

    LISTED

    UL

    MARINE

    48 CAPRI

  • 8/10/2019 Capri Cable Gland

    49/100

    ADE 6FLC

    Features :

    Standard nickel-plated brass material for superior corrosion resistance.

    Neoprene seal and resin certified from -60c to +80C. Provides flameproof seal on the wires and the outer sheath of the unarmoured cables.

    Red cap nut : compound inside.

    Fully inspectable sealing and armour clamping and crimping including deluge boot.

    Armour clamping and bonding with no reversible components for easyinstallation, minimizing error.

    Related accessories: see pages 58 to 67.

    Caution: with non-armoured cable, braided cable or armoured cable without armourfastening, a cable clamping must be realized within a range of 300 mm from theextremity of the cable gland. A Capri clamping module can be used, see page 61.

    Type of Cable Gland With liquid resin, barrier type

    Cable type Steel tape armoured cable

    Steel wire armoured cable

    Steel wire braided cable

    Braided marine shipboard cable

    Certifications and Compliances LCIE 97 ATEX 6008X II GD ExdIIC/ExeII/ExtD

    IECEx LCI 05.0004X

    NEMA 4X and IP68 with sealing washer

    CEPEL cepel-EX-558/05X NEPSI NGYJ071336U & GYJ071337U

    DNV N E-10892

    GOST-R : POCC FR Bo2011

    Lloyds

    OptionsGland Type

    CAP56959 4EXAMPLE:

    9 Stainless steel (316L)

    8 Bronze

    7 Aluminum

    OPTIONS(replace the last digit with option number) :

    GLANDSIZE

    ENTRY THREAD SIZETHREADLENGTH

    E

    ISO / (NPT)

    CABLE

    MAXARMOUR

    THICKNESSL

    HEXAGONE

    CONDISO Reference NPT Reference

    INNERSHEATH

    OUTERSHEATH

    CONDUCTORA B

    Min Max Min Max Max

    number Max

    4 16 CAP569594 3/8 CAP571594 15 (12) 4 7.5 6 12 6,5 5 X 1,5 0,9 36 15 19 40

    4 20 CAP569674 1/2 CAP571074 15 (22,2) 4 7.5 8.5 16 6,5 5 X 1,5 1,25 36 15 24 40

    5 20 CAP569674 1/2 CAP571674 15 (22,2) 6.5 11 12 21 9,5 5 X 2,5 1,25 42 19 24 40

    6 20 CAP569694 1/2 CAP571694 15 (22,2) 9 14.5 16 27.5 12 8 X 2,5 1,25 48 24 30 40

    6 25 CAP569704 3/4 CAP571704 15 (22,5) 9 14.5 16 27.5 12 8 X 2,5 1,6 48 24 30 40

    7 25 CAP569794 3/4 CAP571794 15 (22,5) 12 19.5 21 34 17 12 X 2,5 1,6 58 30 41 30

    CEPEL ExNEPSI

    49CAPRI

  • 8/10/2019 Capri Cable Gland

    50/100

    NEWCAP MS-e and NEWCAP CT-e

    MS-e : METALL I C S TANDARD

    >For unarmoured cable

    or CWB cable

    >IP68

    > Compliance

    >Nickel plated brass and

    Stainless steel

    >Integrated O-ring NEWCAP MS-epage 52

    NEWCAP CT-e

    page 53

    50 CAPRI

  • 8/10/2019 Capri Cable Gland

    51/100

    NEWCAP CT-eMulti diameter contact washer

    CT version dedicated to EMC application

    NEWCAP MS-e CWB cable complatible : 360 braided contact

    NEWCAP MS-e / CT-e IP 68 sealing system

    lamellas system inside

    Integrated O-ring

    CT-e : CONTACT EMC DED I CAT ED

    51CAPRI

  • 8/10/2019 Capri Cable Gland

    52/100

    NEWCAP MS-e

    Type of Cable Gland With elastomeric seal

    Cable type Non-armoured cable Braided cable

    Certifications and Compliances LCIE 10 ATEX 3064X - II2GD - ExeII / ExtD

    IECEx LCI 10 . 0026X - ExeII / ExtD

    EN 50262

    Material: Nickel-plated brass.

    Neoprene sealing ring and dust cover. Polyamide clamping bush.

    Operating temperature range: -20C to +80C.

    Integrated O-ring on fixing thread.

    IP 68: Protection according to NF EN 60529

    Metric thread: ISO-NF EN 60423 & NF EN 50262.

    ENTRY THREAD SIZE ISOLONG FIXING THREAD

    STAINLESS 316L

    GLAND SIZE ISO Reference EBraid

    thickness

    Cable

    L

    HEXAGONE

    E ReferenceDiameter DiameterA B

    Min Max

    4 12 CAP192124 6,5 0,7 4 6,5 18 15 15 15 CAP192129

    4 16 CAP192154 6,5 0,7 4 6,5 18 15 18 15 CAP192159

    5 16 CAP192164 6,5 0,7 5,5 10 24 20 20 15 CAP192169

    5 20 CAP192194 6,5 0,7 5,5 10 24 20 22 15 CAP192199

    6 20 CAP192204 6,5 0,8 7,5 13 27 24 24 15 CAP192209

    6 25 CAP192244 7 0,8 7,5 13 27 24 27 15 CAP192249

    7 25 CAP192254 7 0,85 11,5 18 28 30 30 15 CAP192259

    7 32 CAP192314 8 0,85 11,5 18 28 30 34 15 CAP192319

    8 32 CAP192324 8 0,95 17,5 24,5 30 38 38 15 CAP192329

    8 40 CAP192394 8 0,95 17,5 24,5 30 38 43 15 CAP192399

    9 40 CAP192404 8 1 24 32 33 47 47 15 CAP192409

    9 50 CAP192494 9 1 24 32 33 47 54 15 CAP192499

    10 50 CAP192504 9 1,15 31 40,5 37 57 57 15 CAP192509

    10 63 CAP192624 10 1,15 31 40,5 37 57 68 15 CAP192629

    11 63 CAP192634 10 1,75 39 53 48 75 75 15 CAP192639

    Features :

    IP 68 EMC

    proof

    Dd

    iCEM

    52 CAPRI

  • 8/10/2019 Capri Cable Gland

    53/100

    NEWCAP CT-e

    Type of Cable Gland With elastomeric seal

    Cable type Non-armoured cable Braided cable

    For EMC specific cable and application

    Certifications and Compliances LCIE 10 ATEX 3064X - II2GD - ExeII / ExtD

    IECEx LCI 10 . 0026X - ExeII / ExtD

    EN 50262

    Material: Nickel-plated brass.

    Neoprene sealing ring and dust cover. Polyamide clamping bush.

    Operating temperature range: -20C to +80C.

    Integrated O-ring on fixing thread.

    Metallic contact inside washer.

    IP 68: Protection according to NF EN 60529.

    Metric thread: ISO-NF EN 60423 & NF EN 50262.

    ENTRY THREAD SIZE ISOLONG FIXING THREAD

    STAINLESS 316L

    GLANDSIZE

    ISO Reference EEpaisseurde tresse

    Cable

    L

    HEXAGONE

    E ReferenceDiameter onshield

    DiameterA B

    Min Max

    4 12 CAP193124 6,5 0,7 3 4 6,5 18 15 15 15 CAP193129

    4 16 CAP193154 6,5 0,7 3 4 6,5 18 15 18 15 CAP193159

    5 16 CAP193164 6,5 0,7 4,5 5,5 10 24 20 20 15 CAP193169

    5 20 CAP193194 6,5 0,7 4,5 5,5 10 24 20 22 15 CAP193199

    6 20 CAP193204 6,5 0,8 6 7,5 13 27 24 24 15 CAP193209

    6 25 CAP193244 7 0,8 6 7,5 13 27 24 27 15 CAP193249

    7 25 CAP193254 7 0,85 10 11,5 18 28 30 30 15 CAP193259

    7 32 CAP193314 8 0,85 10 11,5 18 28 30 34 15 CAP193319

    8 32 CAP193324 8 0,95 15 17,5 24,5 30 38 38 15 CAP193329

    8 40 CAP193394 8 0,95 15 17,5 24,5 30 38 43 15 CAP193399

    9 40 CAP193404 8 1 20,5 24 32 33 47 47 15 CAP193409

    9 50 CAP193494 9 1 20,5 24 32 33 47 54 15 CAP193499

    10 50 CAP193504 9 1,15 27,5 31 40,5 37 57 57 15 CAP193509

    10 63 CAP193624 10 1,15 27,5 31 40,5 37 57 68 15 CAP193629

    11 63 CAP193634 10 1,75 34,5 39 53 48 75 75 15 CAP193639

    Features :

    EM

    C

    proof

    Dd

    iCEM

    IP 68

    53CAPRI

  • 8/10/2019 Capri Cable Gland

    54/100

    ECDEP

    ECDEP : S E A L I N G

    >For unarmoured cable

    >IP68

    > Compliance

    >Polyamide black / blue

    >Optional dome head plugECDEP Ex-e

    page 55

    ECDEP Ex-i

    page 56

    54 CAPRI

  • 8/10/2019 Capri Cable Gland

    55/100

    INTEGRATED CLAMPING

    IP68

    A N D I N T E G R A T E D C L A M P I N G I N S I D E

    55CAPRI

  • 8/10/2019 Capri Cable Gland

    56/100

    ECDEP Ex-e

    Type of Cable Gland With elastomeric seal

    Cable type Non-armoured cable

    Certifications and Compliances LCIE 97 ATEX 6007X - II2GD - ExeII / ExtD

    EN 50262

    Features :

    Material: polyamide 6 UL 94 HB halogen free.

    Color: black RAL 9005. Santoprene seal ring.

    Operating temperature range: -20C to +80C

    IP 68: Protection according to NF EN 60529.

    Metric thread: ISO-NF EN 60423 & NF EN 50262.

    Polyamide obturator : see page 63.

    ENTRY THREAD SIZE ISO

    GLAND SIZEENTRY THREAD SIZE

    EOUTER SHEATH

    LHEXAGONE

    ISO Reference A BMin Max

    4 12 CAP441207 9 3,5 6 18 15 15

    5 16 CAP441607 12 5 8 22 19 19

    6 16 CAP441807 9 6 10 22 22 22

    7 20 CAP442007 12 8 13 23 24 24

    8 20 CAP442207 10 10 15 23 26 26

    9 25 CAP442507 13 13 19 29 32 32

    10 32 CAP443207 15 18 25 29 41 41

    11 40 CAP444007 15 24 32 35 52 52

    12 50 CAP445007 16 29 38 40 59 59

    13 63 CAP446307 16 36 44 42 65 65

    56 CAPRI

  • 8/10/2019 Capri Cable Gland

    57/100

    ECDEP Ex-i

    Type of Cable Gland With elastomeric seal

    Cable type Non-armoured cable

    Certifications and Compliances LCIE 97 ATEX 6007X - II2GD - ExeII / ExtD

    EN 50262

    Features :

    Material: polyamide 6 UL 94 HB halogen free.

    Color: black RAL 9005 (body) blue RAL 5012 (capnut). Santoprene seal ring.

    Operating temperature range: -20C to +80C

    IP 68: Protection according to NF EN 60529.

    Metric thread: ISO-NF EN 60423 & NF EN 50262.

    Polyamide obturator : see page 63.

    ENTRY THREAD SIZE ISO

    GLAND SIZEENTRY THREAD SIZE

    EOUTER SHEATH

    LHEXAGONE

    ISO Reference A BMin Max

    4 12 CAP441206 9 3,5 6 18 15 15

    5 16 CAP441606 12 5 8 22 19 19

    6 16 CAP441806 9 6 10 22 22 22

    7 20 CAP442006 12 8 13 23 24 24

    8 20 CAP442206 10 10 15 23 26 26

    9 25 CAP442506 13 13 19 29 32 32

    10 32 CAP443206 15 18 25 29 41 41

    11 40 CAP444006 15 24 32 35 52 52

    12 50 CAP445006 16 29 38 40 59 59

    13 63 CAP446306 16 36 44 42 65 65

    57CAPRI

  • 8/10/2019 Capri Cable Gland

    58/100

    ACCESSORIES

    58 CAPRI

  • 8/10/2019 Capri Cable Gland

    59/100

    61 Compound stopper box Exd

    ADE clamping module

    ADE 4F lead sheath washer

    62 Locknut

    Earth tag

    63 Stopping plug

    Obturator

    64 Reducers / Adaptors selection table

    65 Gasket

    65 Serrated washer

    Shroud66 Other non certifi cated accessories

    Serrated shroud, obutrators

    Contents

    59CAPRI

  • 8/10/2019 Capri Cable Gland

    60/100

    Certified Accessories

    Solution for conduit or

    cable solutions

    Designed to seal conductorsentry to the enclosure via

    conduit or to enable an existing

    compression gland to be

    converted to barrier gland.

    CompoundStopper BoxEx d

    60 CAPRI

  • 8/10/2019 Capri Cable Gland

    61/100

    COMPOUND STOPPER BOX Exd

    SELECTION TABLE

    Can be used complementary with CAPRIFLEX conducts

    Male Female Reference 6 units Thread

    length

    20 M20 CAP661804 30 15

    20 1/2 CAP662404 30 15

    25 M25 CAP661904 38 15

    25 3/4 CAP662504 38 15

    32 M32 CAP662004 47 15

    32 1 CAP662604 47 15

    1/2 1/2 CAP662104 33 17

    1/2 M20 CAP662704 33 17

    3/4 3/4 CAP662204 41 17

    3/4 M25 CAP662804 41 17

    * For stainless steel replace last digit with 9.

    ADE CLAMPING MODULE Material : nickel-plated brass and stainless steel washer andscrews

    SELECTION TABLE

    CABLE RANGE SIZE FOR HEXAGON WIDTH THICKNESS REFERENCE

    4 - 8,5 4 15 18 5 CAP810434

    6 - 11 5 19 22 5 CAP810534

    8.5 - 16 6 24 27,5 6 CAP810634

    12 - 21 7 30 33,5 8 CAP810734

    16 - 27,5 8 41 45 8 CAP810834

    21 - 34 9 48 52 9,5 CAP810934

    27 - 41 10 55 59 9,5 CAP811034

    33 - 48 11 64 69 12 CAP811134

    40 - 56 12 72 78 12 CAP811234

    47 - 65 13 85 92 16 CAP811334

    54 - 74 14 95 103 16 CAP811434

    63 - 83 15 110 118 18 CAP811534

    72 - 93 16 120 128 18 CAP811634

    ADE 4F LEAD SHEATH WASHER Material : Natural brass

    SELECTION TABLE

    Size ADE 4F

    OUTER LEAD SHEATH

    REFERENCEMIN MAX

    5 4 7.5 CAP560530

    6 6 11 CAP560630

    7 9 15 CAP560730

    8 12 20 CAP560830

    9 16 26.5 CAP560930

    10 21 32.5 CAP561030

    11 28 39.5 CAP561130

    12 33 46.5 CAP561230

    13 40 54.5 CAP561330

    14 46.5 61 CAP561430

    15 54 72.5 CAP561530

    16 63 81.5 CAP561630

    61CAPRI

  • 8/10/2019 Capri Cable Gland

    62/100

  • 8/10/2019 Capri Cable Gland

    63/100

    STOPPING PLUG material : nickel-plated brass

    METRIC SELECTION TABLETHREAD SIZE Reference e

    12 CAP190124 15

    16 CAP190164 15

    20 CAP190204 15

    25 CAP190254 15

    32 CAP190324 15

    40 CAP190404 15

    50 CAP190504 16

    63 CAP190634 17

    75 CAP190754 18

    90 CAP199904 22

    100 CAP191004 22

    110 CAP191014 22

    STOPPING PLUG material : polyamide

    METRIC SELECTION TABLE

    THREADSIZE

    Reference a L e

    12 CAP191127 15 4 15

    16 CAP191167 19 4 15

    20 CAP191207 23 4 15

    25 CAP191257 28 5 15

    32 CAP191327 36 5.5 15

    40 CAP191407 44 5.5 15

    50 CAP191507 54 6 16

    63 CAP191637 67 6.5 17

    STOPPING PLUG material : nickel-plated brass

    NPT SELECTION TABLETHREAD SIZE Reference e

    1/4 CAP190194 12

    3/8 CAP190294 12

    1/2 CAP190394 16

    3/4 CAP190494 16

    1 CAP190594 20

    1-1/4 CAP190694 20

    1-1/2 CAP190794 20

    2 CAP190894 20

    2-1/2 CAP190994 28

    3 CAP191094 30

    3-1/2 CAP191194 32

    4 CAP191294 32

    OBTURATOR material : polyamide

    TABLE DE SELECTION

    N Reference OBTURATOR

    SIZE

    4 CAP250712 1 5.5

    5 CAP250912 2 8

    6 CAP251112 3 10

    7 CAP251312 4 12.3

    8 CAP251612 5 14.3

    9 CAP252112 6 18.3

    10 CAP252912 7 24.3

    11 CAP253612 8 31.5

    12 CAP254212 9 37

    13 CAP254812 10 43

    ISO

    ISO

    NPT

    STOPPING PLUG material : Stainless steel 316L

    METRIC SELECTION TABLE

    THREAD SIZE Reference e

    12 CAP190129 15

    16 CAP190169 15

    20 CAP190209 15

    25 CAP190259 15

    32 CAP190329 1540 CAP190409 15

    50 CAP190509 16

    63 CAP190639 17

    75 CAP190759 18

    90 CAP199909 22

    100 CAP191009 22

    110 CAP191019 22

    STOPPING PLUG material : Stainless steel 316L

    NPT SELECTION TABLE

    THREAD SIZE Reference e

    1/4 CAP190199 12

    3/8 CAP109299 12

    1/2 CAP190399 16

    3/4 CAP190499 16

    1 CAP190599 201-1/4 CAP190699 20

    1-1/2 CAP190799 20

    2 CAP190899 20

    2-1/2 CAP190999 28

    3 CAP191099 30

    3-1/2 CAP191199 32

    4 CAP191299 32

    ISO NPT

    All dimensions in millimeters

    CEPEL ExNEPSI

    63CAPRI

  • 8/10/2019 Capri Cable Gland

    64/100

    64 CAPRI

    FEMALE =====>

    METRIC

    MALE M12 M16 M20 M25 M32 M40 M50 M63 M75 M90 M110

    M12 CAP745334

    M16 CAP745834 CAP740274

    M20 CAP745844 CAP740024 CAP740544

    M25 CAP740034 CAP740294 CAP740814

    M32 CAP740304 CAP740564 CAP741084

    M40 CAP740574 CAP740834 CAP741354

    M50 CAP740844 CAP741104 CAP741624

    M63 CAP741114 CAP741374 CAP741894

    M75 CAP741384 CAP741644 CAP745394

    M90 CAP745854 CAP745864

    M110 CAP745924

    FEMALE =====>

    METRIC/NPT

    MALE 1/4 3/8 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3 3 1/2

    M12 CAP744104

    M16 CAP744184 CAP744194 CAP744694

    M20 CAP744204 CAP744214 CAP744704 CAP744964

    M25 CAP744214 CAP744974 CAP745234

    M32 CAP744724 CAP744984 CAP745244 CAP745504

    M40 CAP744994 CAP745254 CAP745514 CAP745774

    M50 CAP745264 CAP745524 CAP745784 CAP746044

    M63 CAP7452774 CAP745534 CAP745794 CAP746054 CAP746314

    M75 CAP745804 CAP746064 CAP746324 CAP746584

    M90 CAP744284 CAP744294 CAP744304 CAP744314

    M110 CAP744514 CAP744254

    FEMALE =====>

    NPT/NPT

    MALE 1/4 3/8 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3 3 1/2

    1/4 CAP744574 CAP744584

    3/8 CAP745574 CAP744614 CAP744624

    1/2 CAP745594 CAP744874 CAP745134

    3/4 CAP745604 CAP744884 CAP745144 CAP745404

    1 CAP744894 CAP745154 CAP745414 CAP745674

    1 1/4 CAP745164 CAP745424 CAP745684 CAP745944

    1 1/2 CAP745434 CAP745694 CAP745954 CAP746214

    2 CAP745444 CAP745704 CAP745964 CAP746224 CAP746484

    2 1/2 CAP745974 CAP746234 CAP746494 CAP746754

    3 CAP746244 CAP746234

    3 1/2 CAP745654 CAP745664

    4 CAP746834 CAP745734

    FEMALE =====>

    NPT/ISO

    MALE M12 M16 M20 M25 M32 M40 M50 M63 M75 M90 M110

    1/4 CAP740614 CAP740624

    3/8 CAP740884 CAP740894 CAP740904

    1/2 CAP740914 CAP740194 CAP740454 CAP740174

    3/4 CAP740204 CAP740464 CAP740724 CAP740984

    1 CAP740474 CAP740734 CAP740994 CAP741254

    1 1/4 CAP740744 CAP741004 CAP741264 CAP741524

    1 1/2 CAP741014 CAP741274 CAP741534 CAP741794

    2 CAP741284 CAP741544 CAO741804 CAP742064

    2 1/2 CAP741554 CAP741814

    3 CAP741824 CAP742384

    3 1/2

    4

    Reducers / Adaptors Selection Table

    On request LAST CODE DIGIT 9 : STAINLESS 316L / LAST CODE DIGIT 7 : ALUMINUM

  • 8/10/2019 Capri Cable Gland

    65/100

    65CAPRI

    GASKET material : neoprene

    METRIC SELECTION TABLE

    THREAD SIZE Reference D e

    10 CAP221049 15 1,2

    12 CAP221249 18 1,2

    16 CAP221649 22 1,2

    20 CAP222049 24 1,2

    25 CAP222549 30 1,5

    32 CAP223249 42 1,5

    40 CAP224049 52 1,5

    50 CAP225049 63 1,5

    63 CAP226349 7 2

    75 CAP227549 90 2

    90 CAP229049 106 2

    110 CAP221149 126 2

    GASKET material : neoprene

    NPT SELECTION TABLE

    THREAD SIZE Reference D e

    1/4 CAP229014 20 1,5

    3/8 CAP229038 22 1,5

    1/2 CAP229012 27 1,5

    3/4 CAP229034 33 1,5

    1 CAP229010 41 1,5

    1-1/4 CAP229114 52 1,5

    1-1/2 CAP229112 57 1,5

    2 CAP229020 71 2

    2-1/2 CAP229212 85 2

    3 CAP229300 104 2

    3-1/2 CAP229312 120 2

    4 CAP229414 130 2

    GASKET material : Green fiber

    METRIC SELECTION TABLE

    THREAD SIZE Reference D e

    10 CAP221045 15 1,2

    12 CAP221245 18 1,2

    16 CAP221645 22 1,2

    20 CAP222045 27 1,2

    25 CAP222545 35 1,5

    32 CAP223245 43 1,5

    40 CAP224045 55 1,5

    50 CAP225045 69 1,5

    63 CAP226345 82 2

    75 CAP227545 94 2

    90 CAP229045 110 2

    110 CAP221145 130 2

    GASKET material : red fiber

    METRIC SELECTION TABLE

    THREAD SIZE Reference D e

    10 CAP221041 15 1,2

    12 CAP221241 18 1,2

    16 CAP221641 22 1,2

    20 CAP222541 27 1,2

    25 CAP222541 35 1,5

    32 CAP223241 43 1,5

    40 CAP224041 55 1,5

    50 CAP225041 69 1,5

    63 CAP226341 82 2

    75 CAP227541 94 2

    90 CAP229041 110 2

    110 CAP221141 130 2

    GASKET material : Green fiber

    NPT SELECTION TABLE

    THREAD SIZE Reference D e

    1/4 CAP239014 18 1,5

    3/8 CAP239038 22 1,5

    1/2 CAP239012 31 1,5

    3/4 CAP239034 35 1,5

    1 CAP239010 43 1,5

    1 1/4 CAP239114 59 1,5

    1 1/2 CAP239112 69 1,5

    2 CAP239020 79 2

    2 1/2 CAP239212 94 2

    3 CAP239300 110 2

    31/2 CAP239312 119 2

    4 CAP239414 130 2

    GASKET material : red fiber

    NPT SELECTION TABLE

    THREAD SIZE Reference D e

    1/4 CAP219014 18 1,5

    3/8 CAP219038 22 1,5

    1/2 CAP219012 31