Range includes 5 air rates (from 115 to 1395 m3/h)
and 5 models (for wall and ceiling installation,
with casing and concealed), each equipped with 3 or 4 row coil and
with the possibility to add a 1 or 2 row coil for 4 pipe systems.
This is the series with the lowest electrical consumptionin relation to both heat performance as well as working static performance
and is particularly suited to satisfying the strictest energy consumption
needs of class A buildings, and to ensuring excellent acoustic comfort.
Fan Coil Unit with Centrifugal Fanwith EC Brushless Electronic Motorand Inverter Board
Carisma CRC-ECM
1
Technical characteristicsof the main components:For the technical characteristics of the various componentsrefer to Carisma CRC Fan Coil Unit, except forElectronic motor:
The ECM range makes use of the excellent experience
gained with the SkyStar Cassette fan coils with inverter board,
first in the world in production since 2009, and which have had great success
on all markets.
The innovative brushless and sensorless type synchronous electronic motor
with permanent magnets, is controlled by an inverter board designed
and developed in Italy. The board is mounted on the unit, closed
to the motor, without the need to be cooled down by the
air flow.
The air flow rate can be
varied in continuously by means
of a 1-10 V signal generated
by Sabiana controls
or by independent control systems.
The continuous air flow control
improves the acoustic comfort and allows
a more punctual reply to the variation of the thermal loads and a greater stability
of the requested ambient temperature.
The extreme efficiency, also at low speed, makes possible a great reduction
in electric consumption (50% less in comparison to CRC AC motor)
with absorption values under normal operating conditions
that do not exceed 16 Watt. The excellent values of the CRC range in terms of
sound levels have been maintained in all working conditions,without any resonance phenomenon at any frequency.
The full compliance with the Electromagnetic Compatibility Directive
and with the other severe Standards in force is certified by an independent institute.
by designed
mounted on the unit, closed
cooled down by the
three phase permanent magnet brushless electronic
motor that is controlled with current reconstructed according to a BLAC sinusoidal wave.
The inverter board that controls the motor operation
is powered by 230 Volt, single-phase and, with a switching system, it generates
a three-phase frequency modulated, wave form power supply.
The electric power supply required for the machine
is therefore single-phase with voltage of 230 - 240 V and frequency of 50 - 60 Hz.
2
60 60
158 158
7144
125
133
C
100
A
530
630
A
B
170
100
7144
125
133
158 158C
60 60
A
530
A
B
170
153
1711
9 *
7144
125
133
F10
D
E*12 12
511
D22 22
2912
G
H
Ø 15 ext.
230
10012
Feet (optional)
Auxiliary condensate tray (optional)
* Supply frame dimension = E x 119 mm
Dimensions, Weight, Water content
Coil connections on the left
MV model
MO-MVB model
IV-IO model
3
15,416,216,816,217,011,812,613,212,613,4
20,221,422,121,222,416,317,518,217,318,5
24,926,427,326,227,720,522,022,921,823,3
28,830,631,730,332,124,226,027,125,727,5
32,234,035,133,735,527,329,130,228,830,6
17,218,018,618,018,813,614,415,014,415,2
22,523,724,423,524,718,119,320,019,120,3
27,729,230,129,030,522,824,325,224,125,6
32,133,935,033,635,427,028,829,928,530,3
35,937,738,837,439,230,432,233,331,933,7
ROW
S
34
+1+2
ROW
SRO
WS
MV
MO-
MVB
IV-I
O
WEIGHT WITH PACKAGING WEIGHT WITHOUT PACKAGING
7702254544744304542182051452604601851054755565
0,60,80,20,4
9852256696896456692182051452604601851054755565
0,91,30,30,6
12002258849048608842182051452604601851054755565
1,62,20,51,0
141522510991119107510992182051452604601851054755565
1,72,40,51,0
141525510991119107510992482351702704502101104658595
1,92,80,61,2
ABCDEFGHMNOPRSTU
33+13+2
44+1
33+13+2
44+1
MODEL
MODEL
MODEL
9
9
7
7
6
6
4
4
2
2
2 24 46 67 79 9
PR
S
321
T
HB
230
Ø 15 ext.
Ø 1/2" F
W ATER OUTLET
W ATER
INLET
Ø 1/2" F
M
37
ON
T
Ø 15 ext.
BH
230
W ATER
INLETW ATER
OUTLET
Ø 15 ext.
M
37
ON
U
GH
230
Ø 1/2" F
W ATER
INLETW ATER
OUTLET
PR
S
321
U
HG
230
Ø 15 ext.
Ø 1/2" F
W ATER OUTLET
W ATER
INLET
3 or 4 row coils 3 or 4 row coilsHeating
additional coil(1 or 2 rows)
Heatingadditional coil(1 or 2 rows)
Coil connections
MV and MO-MVB model IV-IO model
Weight (kg)
Dimensions, Weight, Water content
Water content (litres)
Dimension (mm)
4
AA
BB
6053,472,654,457,558,97,716,04435
3,404,6
7854,253,315,539,4012,711,025,05041
4,086,3
9454,863,836,4110,9416,113,941,05546
4,627,8
11755,674,567,6213,0621,118,365,06051
5,3510,1
13956,365,208,6914,9525,922,599,06455
5,9812,3
4002,611,933,085,1610,58,49,03728
2,652,9
5003,142,353,766,3014,511,9134334
3,103,9
6103,702,794,477,5019,416,118,54839
3,564,9
7554,393,355,328,9426,121,528,55344
4,136,4
8904,983,846,0910,2532,626,841,05748
4,637,8
3051,971,472,353,955,54,57,03324
2,001,5
3952,451,842,964,978,06,710,03829
2,402,1
4952,942,233,596,0411,19,215,04435
2,802,8
6103,462,674,257,1714,812,122,04940
3,243,6
7353,993,114,958,3719,015,732,05445
3,684,5
2101,421,041,702,857,96,66,03021
1,474,5
2801,801,342,203,7012,09,99,03627
1,796,4
3502,191,652,704,5517,013,812,04233
2,118,5
4302,581,963,215,4322,618,217,04738
2,4210,9
5152,972,283,746,3328,923,925,05142
2,7413,6
1200,740,560,921,551,81,47,03021
0,811,3
1700,980,751,242,102,92,59,03627
1,041,9
2201,190,931,532,614,03,411,04132
1,232,6
2701,391,101,813,095,34,514,54738
1,423,4
3301,611,302,133,646,95,721,05142
1,634,3
CC
AB
AA
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
Inverter Power (V)
Speed
Inverter Power (V)
Speed
Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Heating - Water 70-60°CDp Cooling (E)Dp Heating (E)Fan (E)Sound power (E)Sound pressure (*) Heating (E) Dp Heat. (E)Energy classification FCEER (**)Energy classification FCCOP (***)
Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Heating - Water 70-60°CDp Cooling (E)Dp Heating (E)Fan (E)Sound power (E)Sound pressure (*) Heating (E) Dp Heat. (E)Energy classification FCEER (**)Energy classification FCCOP (***)
1 row heating additionalcoil (Water 70/60°C)
1 row heating additionalcoil (Water 70/60°C)
m3/hkWkWkWkWkPakPaW
dB(A)dB(A)
kWkPa
m3/hkWkWkWkWkPakPaW
dB(A)dB(A)
kWkPa
MODEL
MODEL
CRC–ECM 23
CRC–ECM 73
CRC–ECM 43
CRC–ECM 93
CRC–ECM 63
(E) = Eurovent certified performance. (*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec. (**) FCEER = Energy classification in Cooling. (***) FCCOP = Energy classification in Heating.
(E)(E)
(E)(E)
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CEntering water temperature: +50°C
Water flow rate as for the cooling conditions
2 pipe units. The following standard rating conditions are used:
Units with 3 row coil
5
5753,612,714,507,586,35,216,04435
3,404,6
7554,523,435,739,699,37,725,05041
4,086,3
9105,254,036,7011,3712,19,941,05546
4,627,8
11456,254,878,1213,8216,513,565,06051
5,3510,1
13657,145,639,3916,0320,817,099,06455
5,9812,3
AA
BB
3802,621,913,095,167,36,09,03728
2,652,9
4753,212,363,826,3810,58,5
13,04334
3,103,9
5853,842,844,617,7314,311,818,54839
3,564,9
7354,643,475,619,3920,016,728,55344
4,136,4
8755,344,036,5110,9325,621,041,05748
4,637,8
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
2902,061,492,434,058,26,57,03324
2,001,5
3752,611,903,125,2112,410,210,03829
2,402,1
4753,202,353,876,4817,814,915,04435
2,802,8
5903,862,864,717,9024,820,422,04940
3,243,6
7204,543,415,609,4333,026,932,05445
3,684,5
2001,441,041,702,834,03,06,03021
1,474,5
2651,841,352,193,676,14,89,03627
1,796,4
3402,281,682,754,598,97,212,04233
2,118,5
4152,732,043,315,5712,210,017,04738
2,4210,9
5053,192,413,916,6016,113,525,05142
2,7413,6
1150,780,570,941,573,22,67,03021
0,811,3
1601,070,791,302,185,54,69,03627
1,041,9
2101,330,991,632,758,06,511,04132
1,232,6
2601,591,201,983,3311,09,114,54738
1,423,4
3251,881,442,374,0114,812,621,05142
1,634,3
CC
AB
AA
Inverter Power (V)
Speed
Inverter Power (V)
Speed
Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Heating - Water 70-60°CDp Cooling (E)Dp Heating (E)Fan (E)Sound power (E)Sound pressure (*) Heating (E) Dp Heat. (E)Energy classification FCEER (**)Energy classification FCCOP (***)
Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Heating - Water 70-60°CDp Cooling (E)Dp Heating (E)Fan (E)Sound power (E)Sound pressure (*) Heating (E) Dp Heat. (E)Energy classification FCEER (**)Energy classification FCCOP (***)
1 row heating additionalcoil (Water 70/60°C)
1 row heating additionalcoil (Water 70/60°C)
m3/hkWkWkWkWkPakPaW
dB(A)dB(A)
kWkPa
m3/hkWkWkWkWkPakPaW
dB(A)dB(A)
kWkPa
MODEL
MODEL
CRC–ECM 24
CRC–ECM 74
CRC–ECM 44
CRC–ECM 94
CRC–ECM 64
(E) = Eurovent certified performance. (*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec. (**) FCEER = Energy classification in Cooling. (***) FCCOP = Energy classification in Heating.
(E)(E)
(E)(E)
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CEntering water temperature: +50°C
Water flow rate as for the cooling conditions
2 pipe units. The following standard rating conditions are used:
Units with 4 row coil
6
MV-MVB models
MV, MO-MVB and IV-IO models
Continuous fan speed control with electronic thermostat and summer/winter switchCB-T-ECM
Electronic controls included
Continuous fan speed control with electronic thermostat and summer/winter switch
Continuous fan speed control with electronic thermostat and summer/winter switch
Power unit for CR-T-ECM and CR-DI-ECM remote control, fitted on the unit
Power unit for CR-T-ECM and CR-DI-ECM remote control, not fitted on the unit
CR-T-ECMCR-DI-ECMUPM-ECMUPS-ECM
Wall electronic controls
Electronic controls for MB boards
N.B.: if the electrostatic filter is mounted (CRC–ECM only), use the "IAQ" controls.
Hardware/software supervisory system (to be used with MB board only)
Router for Sabianet
Relay output board for Sabianet
SabianetROUTER-S
SIOS
Sabianet management system for a network of fan coils
MB electronic board fitted on the unit
MB electronic board supplied with separate packaging
Wall control (to be used with MB board only)
RT03 infra-red remote control with fitted receiver, for MV/MO-MVB models (to be used with MB board only)
Control fitted on the unit, for MV/MVB models with left connections (available with right connections, to be used with MB board only)
Control supplied with separate packaging, for MV/MVB models with left connections (available with right connections, to be used with MB board only)
RT03 infra-red remote control with receiver supplied with separate packaging (to be used with MB board only)
RT03 infra-red remote control supplied with separate packaging (to be used with MB board only)
Receiver for RT03 infra-red remote control fitted on the unit, for MV/MO-MVB models (to be used with MB board only)
Receiver for RT03 infra-red remote control supplied with separate packaging (to be used with MB board only)
Multifunction control (to be used with MB board only)
MB-ECM-MMB-ECM-S
T-MB
RM-RT03
T-MB-M
T-MB-S
RS-RT03RT03RM
RSPSM-DI
7
CB – T – ECMcontrol
CR – T – ECMcontrol
and Power Unit
8
9CRCE
-LT-EN
-07-14
Sabiana s.p.a. • via Piave, 53 • 20011 Corbetta • Milano • Italy
phone +39.02.97203.1 r.a. / +39.02.97270429 / +39.02.97270576
fax +39.02.9777282 / +39.02.9772820
www.sabiana.it • [email protected]
The descriptions and illustrations provided in this publication
are not binding: Sabiana reserves the right, whilst maintaining
the essential characteristics of the types described
and illustrated, to make, at any time, without the requirement
to promptly update this piece of literature, any changes
that it considers useful for the purpose of improvement
or for any other manufacturing or commercial requirements.