42
Catalog Low voltage General performance IE2 high efciency motors

Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

Catalog

Low voltageGeneral performanceIE2 high efciency motors

Page 2: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according
Page 3: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

General performanceIE2 high efficiency motorsSizes 71 to 355

ABB’s General performance IE2 high efficiency motors are best suited for applications where simplicity and offthe-shelf availability are paramount. With ABB quality and support these motors have the features appreciated by volume customers and serial OEM’s. Motors have IE2 efficiency.

Technical data

- Cast iron 04-06

Dimension drawings

- Cast iron 07

General performance motors in brief

- Cast iron 08-10

3ABB Motors and Generators | Low voltage General performance IE2 high efficiency motors

Page 4: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

IE2

IP 55 - IC 411 - Insulation class F, temperature rise class B

IE2 efficiency class according to IEC 60034-30; 2008

General performance cast iron motorsTechnical data for totally enclosed squirrelcage three phase motors

Efficiency values are given according to IEC 60034-2-1; 2007.Please note that the values are not comparable without knowing the testing method.ABB has calculated the efficiency values according to indirect method, stray load losses (additional losses) determined from measuring.

IE-class concerns motors from 0.37 kW to 355 kW

Output

kWFrame Size

Speed

r/min

Effciency

Full

load

100%

Power

factor

cos j

3/4

load

75%

1/2

load

50%

Current TorqueMoment of

inertia2J=1/4GD

2kgm

Weight

kg

ABB Motors and Generators | Low voltage General performance IE2 high efficiency motors 4

3000 r/min 415V, 50Hz

0.37 E2BA71A2 2660 72.2 72.2 72 0.80 0.92 3.9 1.3 2.2 2.3 0.00039 11

0.55 E2BA71B2 2680 74.8 74.8 74 0.85 1.2 4.3 2 2.4 2.5 0.00051 11

0.75 E2BA80B2 2895 77.4 77.4 73 0.74 1.8 6.5 2.5 2.4 4.2 0.001 16

1.1 E2BA80C2 2870 79.6 79.6 78 0.80 2.4 6.5 3.7 2.7 3.5 0.0012 18

1.5 E2BA90SLB2 2900 81.3 81.3 79.9 0.86 3 6.5 4.9 2.5 2.6 0.00254 24

2.2 E2BA90SLC2 2885 83.2 83.2 82.2 0.87 4.2 7.0 7.3 1.9 2.5 0.0028 25

3.7 E2BA100LC2 2905 85.5 85.5 85 0.86 7 7.0 12.2 2.9 3.2 0.00575 37

5.5 E2BA132SMB2 2865 87 87 85.8 0.86 10.2 7.0 18.3 2 2.7 0.01275 68

7.5 E2BA132SMC2 2890 88.1 88.1 86.3 0.84 14.1 7.0 24.80 2 3.6 0.01359 70

11 M2BAX160MLA2 2925 89.4 89.7 88.2 0.88 19.6 7.0 36 2.4 3.0 0.0415 105

15 M2BAX160MLB2 2930 90.3 90.7 90.0 0.90 25.9 7.0 49 2.4 3.0 0.0544 120

18.5 M2BAX160MLC2 2934 90.9 91.2 90.4 0.90 31.7 7.0 60 2.6 3.1 0.0581 131

22 M2BAX180MLA2 2936 91.3 91.7 91.0 0.91 37.3 7.0 72 3.0 3.5 0.0679 152

30 M2BAX200MLA2 2940 92.0 92.4 91.5 0.90 50.7 7.0 97 2.5 3.2 0.1077 198

37 M2BAX200MLB2 2950 92.5 92.8 91.7 0.89 62.9 7.0 120 3.0 3.8 0.1332 232

45 M2BAX225SMA2 2956 92.9 92.6 92.0 0.90 75.7 7.0 145 2.4 3.2 0.2443 295

55 M2BAX250SMA2 2960 93.2 93.8 92.8 0.90 91.7 7.0 177 2.6 3.0 0.3160 344

75 E2HX280SMB2 2970 93.8 93.8 92.8 0.92 121 7.0 241 2.3 2.7 1.025 690

90 E2HX280SMC2 2970 94.1 94.1 93.1 0.92 145 7.0 289 2.3 2.5 1.2 685

110 E2BA315SMA2 2980 94.3 94.3 93.3 0.90 180 7.0 353 2.4 2.7 1.41 935

125 E2BA315SMB2k 2980 94.5 94.5 93.5 0.90 204 7.0 401 2.4 2.7 1.61 975

132 E2BA315SMB2 2980 94.6 94.6 93.6 0.90 216 7.0 423 2.4 2.7 1.610 975

160 E2BA315MLA2 2980 94.8 94.8 93.8 0.90 261 7.0 513 2.3 3.0 1.950 1150

200 E2BA315MLC2 2980 95.0 95.0 94.0 0.90 325 7.0 641 2.6 3.0 2.55 1275

250 E2BA355SMA2 2980 95.0 95.0 94.0 0.90 407 7.0 801 1.6 3.0 4.250 1645

315 E2BA355MLA2 2980 95.0 95.0 94.0 0.91 507 7.0 1009 1.7 3.0 5.75 1895

355 E2BA355MLC2 2982 95.0 95.0 94.0 0.90 578 7.0 1137 1.7 3.2 6.525 2000

I , An I / Is n T , Nmn T / Tb n T / Ti n

I / I = Starting currents n

T / T = Locked rotor torquei n

T / T = Breakdown torqueb n

Page 5: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

IE-class concerns motors from 0.37 kW to 355 kW

5ABB Motors and Generators | Low voltage General performance IE2 high efficiency motors

IE2

IP 55 - IC 411 - Insulation class F, temperature rise class B

IE2 efficiency class according to IEC 60034-30; 2008

General performance cast iron motorsTechnical data for totally enclosed squirrelcage three phase motors

Efficiency values are given according to IEC 60034-2-1; 2007.Please note that the values are not comparable without knowing the testing method.ABB has calculated the efficiency values according to indirect method, stray load losses (additional losses) determined from measuring.

IE-class concerns motors from 0.37 kW to 355 kW

Output

kWFrame Size

Speed

r/min

Effciency

Full

load

100%

Power

factor

cos� j

3/4

load

75%

1/2

load

50%

Current TorqueMoment of

inertia2J=1/4GD

2kgm

Weight

kg

1500 r/min 415V, 50Hz

0.37 E2BA71B4 1380 70.1 70.1 68.7 0.83 0.9 4 2.6 1.6 2.1 0.00088 11

0.55 E2BA80A4 1415 75.1 75.1 71.4 0.73 1.4 5 3.7 2 2.8 0.00144 15

0.75 E2BA80D4 1430 79.6 79.6 76.2 0.73 1.8 6 5 2.7 3.2 0.00205 17

1.1 E2BA90SLC4 1435 81.4 81.4 80.9 0.80 2.4 6 7.3 2.7 3.4 0.0044 25

1.5 E2BA90SLD4 1430 82.8 82.8 81 0.83 3 6 10 2.5 3 0.00538 27

2.2 E2BA100LC4 1450 84.3 84.3 82.6 0.78 4.7 7.0 14.5 2.9 3.6 0.00948 36

3.7 E2BA112MB4 1440 86.3 86.3 85.9 0.81 7.4 7.0 24.5 2.5 2.9 0.0125 44

5.5 E2BA132SMB4 1460 87.7 87.7 86.8 0.80 10.9 7.0 36 1.8 2.4 0.03282 70

7.5 E2BA132SMC4 1450 88.7 88.7 86 0.81 14.5 7.0 49.4 1.6 2.4 0.03659 73

9.3 M2BAX160MLJ4 1460 89.3 89.8 88.0 0.84 17.4 7.0 61 2.3 2.9 0.0738 107

11 M2BAX160MLA4 1463 89.8 90.4 89.4 0.85 20.2 7.0 72 2.3 2.9 0.0840 115

15 M2BAX160MLB4 1463 90.6 91.2 90.2 0.84 27.6 7.0 98 2.5 3.1 0.1025 134

18.5 M2BAX180MLA4 1464 91.2 91.8 90.9 0.84 33.8 7.0 121 2.9 3.5 0.1217 155

22 M2BAX180MLB4 1465 91.6 92.1 91.2 0.83 40.5 7.0 143 2.5 3.2 0.1396 171

30 M2BAX200MLA4 1474 92.3 92.5 91.8 0.84 54.1 7.0 194 2.7 3.5 0.2572 229

37 M2BAX225SMA4 1478 92.7 93.1 92.2 0.85 65.7 6.5 239 2.3 2.7 0.3605 267

45 M2BAX225SMB4 1478 93.1 93.5 92.6 0.84 80.5 7.0 291 2.4 2.9 0.4314 304

55 M2BAX250SMA4 1478 93.5 93.7 92.9 0.85 96.8 7.0 355 2.7 3.0 0.5331 342

75 E2HX280SMB4 1478 94.0 94.0 93.0 0.87 128 7.0 485 2.4 2.7 1.11 670

90 E2HX280SMC4 1479 94.2 94.2 93.2 0.85 156 7.0 581 2.6 2.8 1.425 730

110 E2BA315SMA4 1486 94.5 94.5 93.5 0.88 184 7.0 707 2.3 2.8 2.387 930

125 E2BA315SMB4k 1486 94.6 94.6 93.6 0.86 214 7.0 803 2.0 2.7 2.65 960

132 E2BA315SMB4 1486 94.7 94.7 93.7 0.86 225 7.0 848 2.3 2.7 2.65 960

160 E2BA315MLA4 1485 94.9 94.9 93.9 0.87 270 7.0 1029 2.3 2.6 3.375 1110

200 E2BA315MLC4 1485 95.1 95.1 94.1 0.88 332 7.0 1286 2.4 2.8 4.25 1260

250 E2BA355SMA4 1486 95.1 95.1 94.1 0.87 420 7.0 1607 2.0 2.5 6.625 1620

315 E2BA355MLA4 1486 95.1 95.1 94.1 0.87 530 7.0 2024 2.5 3.0 8.25 1870

355 E2BA355MLB4 1486 95.1 95.1 94.1 0.87 597 7.0 2281 2.2 3.0 10 2110

I , An T , Nmn I / Is n T / Tb n T / Ti n

I / I = Starting currents n

T / T = Locked rotor torquei n

T / T = Breakdown torqueb n

Page 6: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

IE2

IP 55 - IC 411 - Insulation class F, temperature rise class B

IE2 efficiency class according to IEC 60034-30; 2008

General performance cast iron motorsTechnical data for totally enclosed squirrelcage three phase motors

Efficiency values are given according to IEC 60034-2-1; 2007.Please note that the values are not comparable without knowing the testing method.ABB has calculated the efficiency values according to indirect method, stray load losses (additional losses) determined from measuring.

IE-class concerns motors from 0.37 kW to 355 kW

I / I = Starting currents n

T / T = Locked rotor torquei n

T / T = Breakdown torqueb n

Output

kWFrame Size

Speed

r/min

Effciency

Full

load

100%

Power

factor

cos� j

3/4

load

75%

1/2

load

50%

Current TorqueMoment of

inertia2J=1/4GD

2kgm

Weight

kg

1000 r/min 415V, 50Hz

0.37 E2BA80A6 915 69 69 64.4 0.69 1.1 6 3.9 1.8 2.2 0.00187 15

0.55 E2BA80B6 920 72.9 72.9 70.6 0.71 1.5 6 5.7 1.8 2.2 0.00239 17

0.75 E2BA90SLC6 960 75.9 75.9 69.7 0.60 2.3 6 7.5 2.3 3.1 0.00444 25

1.1 E2BA90SLE6 930 78.1 78.1 75.4 0.66 3 6 11.3 1.9 2.3 0.0054 28

1.5 E2BA100L6 950 79.8 79.8 76.8 0.69 3.8 6 15 2.2 2.7 0.00873 37

2.2 E2BA112MB6 950 81.8 81.8 79.3 0.69 5.4 7 22.1 1.7 2.3 0.0125 44

3.7 E2BA132SMB6 970 84.3 84.3 82.4 0.70 8.8 7 36.4 1.5 2.2 0.03336 69

5.5 E2BA132SMF6 965 86 86 85 0.71 12.5 7 54.4 2.5 2.8 0.0487 86

7.5 M2BAX160MLA6 967 87.2 88.0 86.8 0.79 15.3 6.5 74 1.9 2.6 0.0890 122

9.3 M2BAX160MLJ6 968 88.0 88.6 87.8 0.79 18.9 6.5 92 2.1 2.8 0.1190 141

11 M2BAX160MLB6 970 88.7 89.2 88.5 0.78 22.3 7.0 108 2.3 3.0 0.1293 147

15 M2BAX180MLA6 972 89.7 90.1 89.4 0.76 30.9 7.0 147 2.3 3.2 0.1522 173

18.5 M2BAX200MLA6 972 90.4 90.8 90.0 0.79 36.5 6.0 182 1.7 2.5 0.1980 190

22 M2BAX200MLB6 973 90.9 91.2 90.6 0.79 43.1 6.0 216 1.7 2.5 0.2384 212

30 M2BAX225SMA6 985 91.7 92.0 91.2 0.83 55.2 6.5 291 2.3 2.8 0.5687 284

37 M2BAX250SMA6 985 92.2 92.4 91.9 0.82 68.5 6.0 359 2.0 2.6 0.8042 337

45 E2HX280SMA6 988 92.7 92.7 90.7 0.84 80 7.0 435 2.2 2.4 1.8 590

55 E2HX280SMB6 988 93.1 93.1 91.1 0.84 98 7.0 532 2.2 2.4 2.025 600

75 E2BA315SMA6 989 93.7 93.7 91.7 0.85 131 7.0 724 2.4 2.7 3.887 932

90 E2BA315SMB6 990 94.0 94 92.0 0.85 157 7.0 868 2.4 2.8 4.8 1005

110 E2BA315SMC6 990 94.3 94.3 92.3 0.85 191 7.0 1061 2.5 3.0 5.45 1072

125 E2BA315MLC6k 990 94.4 94.4 92.4 0.86 214 7.0 1206 2.5 3.0 7.05 1305

132 E2BA315MLC6 988 94.6 94.6 92.6 0.86 226 7.0 1276 2.3 2.6 7.05 1305

160 E2BA355SMA6 989 94.8 94.8 92.8 0.85 276 7.0 1545 2.0 2.7 9.80 1675

200 E2BA355SMB6 990 95.0 95.0 93.0 0.84 349 7.0 1929 2.5 2.8 12.625 1800

250 E2BA355MLA6 988 95.0 95.0 93.0 0.85 431 7.0 2416 2.3 2.7 13.75 1940

315 E2BA355MLB6 990 95.0 95.0 93.0 0.84 549 7.0 3039 2.5 2.8 15.06 2040

I , An T , Nmn

ABB Motors and Generators | Low voltage General performance IE2 high efficiency motors 6

I / Is n T / Tb n T / Ti n

Page 7: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

General performance IE2 high efficiency motors Sizes 71 - 355Dimension drawings

Above table gives the main dimensions in mm.

Foot-mounted motor IM1001, B3 Flange-mounted motor IM3001, B5

IM 1001. IM B3 IM 1001. IM B3 IM 3001. IM B5IM 3001. IM B5

HD

KB

B’

CE

F

GA

D

L

H

S M

45°

22.5

°

S

M

Size 71 to 200 Size 225 to 355

P N

Motor

Size 2 4-6 2 4-6 2 4-6 2 4-6 2 4-6 A B B’ C HD K H M N P S

General performance cast iron motors

71 14 14 16 16 5 5 30 30 264 264 112 90 - 45 178 7 71 130 110 160 10

80 19 19 21.5 21.5 6 6 40 40 321 321 125 100 - 50 195 10 80 165 130 200 12

90 24 24 27 27 8 8 50 50 357 357 140 100 125 56 219 10 90 165 130 200 12

100 28 28 31 31 8 8 60 60 381 381 160 140 - 63 247 12 100 215 180 250 15

112 28 28 31 31 8 8 60 60 403 403 190 140 - 70 259 12 112 215 180 250 15

132 38 38 41 41 10 10 80 80 533 533 216 140 178 89 300 12 132 265 230 300 15

160 42 42 45 45 12 12 110 110 586 586 1), 1’) 254 210 254 108 414 14.5 160 300 250 350 19

180 48 48 51.5 51.5 14 14 110 110 683 683 2) 279 241 279 121 434 14.5 180 300 250 350 19

200 55 55 59 59 16 16 110 110 728 728 3) 318 267 305 133 474 18.5 200 350 300 400 19

225 55 60 59 64 16 18 110 140 854 854 4) 356 286 311 149 540 18.5 225 400 350 450 19

250 60 65 64 69 18 18 140 140 882 882 406 311 349 168 585 24 250 500 450 550 19

280 65 75 69 79.5 18 20 140 140 1040 1040 457 368 419 190 728 24 280 500 450 550 19

315SM 65 80 69 85 18 22 140 170 1169 1199 508 406 457 216 872 28 315 600 550 660 24

315ML 65 90 69 95 18 25 140 170 1215 1245 508 457 508 216 872 28 315 600 550 660 24

355SM 75 100 79.5 106 20 28 140 210 1399 1469 610 500 560 254 965 28 355 740 680 800 24

355ML 75 100 79.5 106 20 28 140 210 1504 1574 610 560 630 254 965 28 355 740 680 800 24

7ABB Motors and Generators | Low voltage General performance IE2 high efficiency motors

D

Poles

GA

Poles

F

Poles

E

Poles

L max

Poles

Motor D GA F E L Max A B B’ C HD K H M N P S

355MLB4 100 106 28 210 1680 610 560 630 254 965 28 355 740 680 800 24

355MLC2 75 79.5 20 140 1610 610 560 630 254 965 28 355 740 680 800 24

1) M2BAX160MLC2, B4, J6 L = 626

1') M2BAX160MLB6 L = 646

2) M2BAX180MLB4, A6 L = 703

3) M2BAX200MLB2, A4, B6 L = 768

4) M2BAX225SMB4, A6 L = 884

Page 8: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

General performance IE2 cast iron motors in brief

ABB Motors and Generators | Low voltage General performance IE2 high efficiency motors 8

Size

Stator

Feet

Bearing end shields

Bearings

Axially-locked

Bearing seals

Lubrication

Terminal Box Cover

Connections

Fan

Fan Cover

Stator winding

Rotor winding

Balancing method

Key ways

Enclosure

Cooling method

Drain holes

Lifting lugs

Material Cast Iron Grade 150:ISO 185

Paint colour shade Munsell blue 8B 4.5/3.25 / NCS 4822 B05G

Surface Treatment Aliphatic polyurethane enamel paint   70µm

Fixed feet

Material Cast Iron Grade 150:ISO 185

Material Cast Iron Grade 150:ISO 185

Paint colour shade Munsell blue 8B 4.5/3.25 / NCS 4822 B05G

Surface Treatment Aliphatic polyurethane enamel paint   70µm

D-end 6203-2Z/C3 6204-2Z/C3 6205-2Z/C3 6206-2Z/C3 6206-2Z/C3 6208-2Z/C3

N-end 6202-2Z/C3 6203-2Z/C3 6204-2Z/C3 6205-2Z/C3 6205-2Z/C3 6208-2Z/C3

Inner Bearing Cover As stranded, locked at D-end

D-end V-ring

N-end Labyrinth seal

Permanently lubricated shielded bearings. Grease temp. range -40 to +160°C

Material Sheet of steel, Cold rolled

Surface Treatment Similar to stator

Screws Steel

Threaded opening 2 x M16 2 x M25 2 x M32

2Max Cu area mm 4 6 10

Terminal Box Cable lugs, 6 terminals

Screws M4 M5

Material Polypropylene, Reinforced with 20% glass fibre

Material Steel

Paint colour shade Black RAL 9011

Surface Treatment Polyster Powder coated   50µm

Material Copper

Insulation class Insulation class F, Temperature rise class B, unless otherwise stated

Winding protection Optional

Material Pressure die cast aluminum

Half Key balancing as standard

Closed Key Way

IP 55

IC 411

Drain holes with closable plastic plugs, open on delivery

Bolted to the Stator

71 80 90 100 112 132

Page 9: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

General performance IE2 cast iron motors in brief

Stator winding

Rotor winding

Balancing method

Key ways

Enclosure

Cooling method

Drain holes

Lifting lugs

9ABB Motors and Generators | Low voltage General performance IE2 high efficiency motors

Size 160 180 200 225 250

Stator

Feet

Bearing end shields

Bearings

Axially-locked

Bearing seals

Lubrication

Terminal Box

Connections

Fan

Fan Cover

M2BA

Material Cast iron grade 200 : ISO 185

Paint colour shade Munsell blue 8B 4.5/3.25 / NCS 4822 B05G

Surface Treatment Aliphatic polyurethane enamel paint   70µm

Integrated with stator

Material Cast iron grade 200 : ISO 185

Material Cast iron grade 200 : ISO 185

Paint colour shade Munsell blue 8B 4.5/3.25 / NCS 4822 B05G

Surface Treatment Aliphatic polyurethane enamel paint   70µm

D-end 6209-2Z/C3 6210-2Z/C3 6212-2Z/C3 6213-2Z/C3 6215-2Z/C3

N-end 6209-2Z/C3 6209-2Z/C3 6209-2Z/C3 6210-2Z/C3 6212-2Z/C3

Inner Bearing Cover As standard, locked at D-end

D-end V-ring

N-end V-ring

Permanently lubricated shielded bearings

Material Sheet of Steel, Cold Rolled

Surface Treatment Similar to stator

Screws Steel 8.8

Threaded opening (2 x M40 + M16)*) (2 x M50 + M16)

2Max Al-area mm 70 120

Terminal Box 6 terminals for connection with cable lugs (not included)

Screws M6 M10

Material Polypropylene, Reinforced with 20% glass fibre

Material Sheet of Steel, Cold Rolled

Paint colour shade Munsell blue 8B 4.5/3.25 / NCS 4822 B05G

Surface Treatment Similar to stator

Material Copper

Insulation Insulation class F

Material Diecast aluminum

Half Key Balancing

Open Key Way

IP 55

IC 411

Drain holes with closable plastic plugs, open on delivery

Integrated with the stator

Page 10: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

Size 280 2-6 Pole 315 2 Pole 315 4-6 Pole 355 2 Pole 355 4-6 Pole

Stator winding

Rotor winding

Balancing method

Key ways

Enclosure

Cooling method

Drain holes

Lifting lugs

General performance IE2 cast iron motors in brief

Stator

Feet

Bearing end shields

Bearings

Axially-locked

Bearing seals

Lubrication

Terminal Box

Connections

Fan

Fan Cover

ABB Motors and Generators | Low voltage General performance IE2 high efficiency motors 10

Material Cast iron grade 150, IS:210

Paint colour shade Munsell blue 8B 4.5/3.25 / NCS 4822 B05G

Surface Treatment Aliphatic polyurethane paint   80µm

Integrated with stator

Material Cast iron grade 150, IS:210

Material Cast iron grade 150, IS:210

Paint colour shade Munsell blue 8B 4.5/3.25 / NCS 4822 B05G

Surface Treatment Aliphatic polyurethane paint   80µm

D-end 6316/C3 6316/C3 6319/C3 6319/C3 6322/C3

N-end 6315/C3 6316/C3 6316/C3 6319/C3 6319/C3

Inner Bearing Cover As stranded, locked at D-end

D-end Oil Seal

N-end

Regreasable Bearings, Regreasing nipple M10X1

Material Cast iron grade 150, IS:210

Surface Treatment Similar to stator

Screws Steel

Threaded opening 2 x 2” BSC 2 x 2-1/2” BSC

2Max Al-area mm 185 240

Terminal Box 6 terminals for connection with cable lugs (not included)

Screws M12 M16

Material Polypropylene, Reinforced with 20% glass fibre Aluminium

Material Sheet of steel, Cold Rolled

Paint colour shade Munsell blue 8B 4.5/3.25 / NCS 4822 B05G

Surface Treatment Similar to stator

Material Copper

Insulation Insulation class F

Material Diecast aluminum

Half Key Balancing

Open Key Way

IP 55

IC 411

Drain holes with closable plastic plugs, open on delivery

Bolted to the Stator

Page 11: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according
Page 12: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

CA

T-

02 R

2 2

1/0

5/2

014

www.abb.co.in

South

No. 49, 5th Floor, West Wing, Khanija Bhawan, Race Course Road, Bangalore 560 001Tel: +91 80 22949250 / 6677

ChennaiIst Floor, "Prestige Palladium Bayen", Opp. BSNL Shop No. 129-140, Greams Road,Chennai 600008Tel.: +91 44 4222829 / 550 / 551

CoimbatoreTel: +91 422 2305934Fax: +91 422 2300371

HyderabadTel: +91 40 27906736 / 29Fax: +91 40 27906648

KochiTel: +91 484 2421481

VisakhapatnamTel: +91 891 2795837Fax: +91 891 2538188

ABB India Limited32, Industrial Area,N.I.T., Faridabad - 121 001Tel: +91 129 2448100Fax: +91 129 4023006Helpline No. : 1800 425 0707

Regional Marketing Offices :

North

14, Mathura Road,Faridabad - 121 003Tel: +91 129 - 2275592/9627Fax: +91 129 - 2275019

ChandigarhSCO13, 14, 15, 3rd Floor,Sec. 34 A, ChandigarhTel: +91 172 5214400Fax: +91 172 2601618

JaipurTel: +91 141 2744024Fax: +91 141 2744027

LucknowTel: +91 522 2209436Fax: +91 522 2209478

LudhianaTel: +91 161 4656831Fax: +91 161 4656830

DehradunTel: +91 135 2760654Fax: +91 135 2760655

East

Omega Building, 17th Floor,Bengal Intelligent Park,Block EP & GP, Sector V,Salt Lake City, Kolkata 700 091Tel: +91 33 66213135Fax: +91 33 66213187

JamshedpurKashikunj Building, Road No. 2, Bistpur Jamshedpur - 831011Tel: +91 657 6619201

Raipur4th & 5th Floor, Maruti HeightsAamanaka, G.E. Road,Raipur - 492 099Tel: +91 771 4213200Fax: +91 771 4213222

Bhubaneshwar1st Floor, Plot no. A-51/1, Bhoi Nagar, Sachivaiya Marg, Unit-9, BhubaneshwarTel.: +91 674654/8701 - 715

West

ABB HouseDr. S B PathBallard Estate, Mumbai 400 038Tel: +91 22 66159888Fax: +91 22 66314203

BhopalPlot No. 34, Sector A, Near Bhopal Medical Centre, Indrapuri, Bhopal 462 021Tel: +91 755 6463603

PuneTel: +91 20 66243838Fax: +91 20 66016255

VadodaraTel: +91 265 2642141-42Fax: +91 265 2638911

NagpurTel: +91 712 6461145, 46, 48, 49Fax: +91 712 2290283

IndoreTel: +91 9981146044

Note:

We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.

We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utlilization of its content - in whole or in parts - is forbidden without ABB's prior written consent.

Page 13: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

Low voltageGeneral performanceIE3 efficiency cast iron motors

Catalog

Page 14: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

ABB Motors and Generators I Low voltage general performance IE3 efficiency motors 2

Page 15: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

General performanceIE3 efficiency cast iron motorsSizes 71 to 355

ABB's General performance IE3 efficiency motors are best suited forindustries where quality, robustness and reliability are paramount. WithABB quality and support these motors have features appreciated byindustry customers. Motors have IE3 efficiency.

Technical data

Page

Dimension drawings

04-06

Page 07

General performance motors in brief

Page

ABB Motors and Generators I Low voltage general performance IE3 efficiency motors 3

8-10

Page 16: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

General performance IE3 efficiency cast iron motorsTechnical data for totally enclosed squirrelcage three phase induction motors

IE3

IP 55 - lC 411 - Insulation class F, temperature rise class B

IE3 efficiency class according to IEC 60034-30-1; 2014

Efficiency values are given according to IEC 60034-2-1; 2014.Please note that the values are not comparable without knowing the testing method.ABB has calculated the efficiency values according to indirect method, stray load losses(additional losses) determined from measuring.

IE-class concerns motors from 0.37 kW to 355 kW

l / ls n

T / Ts n

T / Tb n

=

=

=

Starting current

Locked rotor torque

Breakdown torque

9.3

11

15

18.5

22

30

37

45

55

75

90

110

125

132

160

200

250

315

355

M2BAX160MLJ2

M2BAX160MLA2

M2BAX160MLB2

M2BAX160MLC2

M2BAX180MLA2

M2BAX200MLA2

M2BAX200MLB2

M2BAX225SMA2

M2BAX250SMA2

E3HX280SMB2

E3HX280SMC2

E3BA315SMA2

E3BA315SMB2K

E3BA315SMB2

E3BA315MLA2

E3BA315MLC2

E3BA355SMA2

E3BA355MLA2

E3BA355MLC2

2940

2942

2944

2995

2955

2957

2958

2966

2968

2970

2970

2980

2980

2980

2980

2980

2980

2980

2982

90.7

91.2

91.9

92.4

92.7

93.3

93.7

94.0

94.3

94.7

95.0

95.2

95.3

95.4

95.6

95.8

95.8

95.8

95.8

90.8

91.5

92.1

92.9

93.2

93.6

94.1

94.1

94.3

94.7

95.0

95.2

95.3

95.4

95.6

95.8

95.8

95.8

95.8

89.7

90.8

91.3

92.5

92.7

93.2

93.6

93.3

93.5

93.7

94.0

94.2

94.3

94.4

94.6

94.8

94.8

94.8

94.8

0.89

0.90

0.88

0.90

0.90

0.89

0.90

0.87

0.89

0.90

0.90

0.88

0.89

0.89

0.90

0.90

0.90

0.91

0.90

16.2

18.7

26.0

31.2

37.1

51.0

61.8

77.3

92.5

122

146

183

205

216

259

323

403

503

573

7.7

7.7

7.7

7.7

7.7

7.0

7.0

7.0

6.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

30.1

35.7

48.6

59.8

71.0

96.8

119.3

144.7

176.9

241

289

353

401

423

513

641

801

1009

1137

2.8

2.8

3.0

3.0

3.0

2.9

2.9

2.9

2.8

2.5

2.0

2.6

2.6

2.5

2.6

2.6

2.5

2.0

2.5

3.8

3.6

4.0

3.9

3.7

3.3

3.4

3.4

3.1

2.8

2.6

2.9

2.9

2.7

2.9

3

3

2.9

3

0.053

0.057

0.063

0.076

0.110

0.182

0.222

0.296

0.426

1.025

1.214

1.65

1.8

1.8

2.3

2.55

4.75

5.75

6.52

115

118

126

144

181

230

257

287

344

700

740

935

970

970

1150

1310

1905

1950

2260

Output

KWFrame Size

Speed

r/min

Efficiency

Full

load

100%

3/4

load

75%

1/2

load

50%

Power

factor

cos Ø

Current TorqueMoment of

inertia2J=1/4GD

2kgm

Weightkg

l , An l / ls n T , Nmn T / Ts n T / Tb n

3000 r/min 415V, 50Hz

ABB Motors and Generators I Low voltage general performance IE3 efficiency motors 4

M2BAX71MC2

M2BAX71MB2

M2BAX80MC2

M2BAX80MD2

M2BAX90SB2

M2BAX90SLA2

M2BAX100LKB2

M2BAX132SMA2

M2BAX132SMB2

0.37

0.55

0.75

1.1

1.5

2.2

3.7

5.5

7.5

2790

2785

2875

2865

2885

2890

2900

2900

2905

75.5

78.1

80.7

82.7

84.2

85.9

87.8

89.2

90.1

75.4

78.4

80.0

83.4

84.6

86.7

88.1

89.6

90.5

72.7

76.4

76.7

81.9

83.0

85.8

86.8

88.9

89.7

0.81

0.80

0.80

0.84

0.86

0.88

0.88

0.86

0.86

0.84

1.22

1.62

2.2

2.9

4.0

6.7

10.0

13.5

4.6

4.6

6.2

6.7

6.1

7.0

7.5

6.6

6.3

1.3

1.9

2.5

3.7

5.0

7.3

12.1

18.0

24.6

2.2

2.3

3.0

3.0

2.9

3.0

3.5

2.3

2.5

2.5

2.6

3.6

3.6

3.3

3.5

3.9

3.4

3.5

0.00033

0.00041

0.00080

0.00119

0.00224

0.00304

0.00756

0.1630

0.01820

9

10

14

17

21

25

42

69

74

Page 17: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

General performance IE3 efficiency cast iron motorsTechnical data for totally enclosed squirrelcage three phase induction motors

IE3

IP 55 - lC 411 - Insulation class F, temperature rise class B

IE3 efficiency class according to IEC 60034-30-1; 2014

Efficiency values are given according to IEC 60034-2-1; 2014.Please note that the values are not comparable without knowing the testing method.ABB has calculated the efficiency values according to indirect method, stray load losses(additional losses) determined from measuring.

l / ls n

T / Ts n

T / Tb n

=

=

=

Starting current

Locked rotor torque

Breakdown torque

ABB Motors and Generators I Low voltage general performance IE3 efficiency motors 5

9.3

11

15

18.5

22

30

37

45

55

75

90

110

125

132

160

200

250

315

355

Output

KWFrame Size

Speed

r/min

Efficiency

Full

load

100%

3/4

load

75%

1/2

load

50%

Power

factor

cos Ø

Current TorqueMoment of

inertia2J=1/4GD

2kgm

Weightkg

l , An l / ls n T , Nmn T / Ts n T / Tb n

1500 r/min 415V, 50Hz

M2BAX160MLJ4

M2BAX160MLA4

M2BAX160MLB4

M2BAX160MLA4

M2BAX180MLB4

M2BAX200MLA4

M2BAX225SMA4

M2BAX225SMB4

M2BAX250SMA4

E3HX280SMB4

E3HX280SMC4

E3BA315SMA4

E3BA315SMB4K

E3BA315SMB4

E3BA315MLA4

E3BA315MLC4

E3BA355SMA4

E3BA355MLA4

E3BA355MLB4

1475

1475

1475

1479

1479

1482

1482

1482

1482

1478

1479

1486

1486

1486

1485

1485

1486

1486

1486

91.0

91.4

92.1

92.6

93.0

93.6

93.9

94.2

94.6

95.0

95.2

95.4

95.5

95.6

95.8

96.0

96.0

96.0

96.0

90.9

91.5

92.2

93.0

93.5

93.8

94.2

94.6

94.7

95.0

95.2

95.4

95.5

95.6

95.8

96.0

96.0

96.0

96.0

89.5

90.5

91.3

92.5

93.0

93.2

93.8

94.3

94.1

94.0

94.2

94.4

94.5

94.6

94.8

95.0

95.0

95.0

95.0

0.79

0.80

0.80

0.82

0.82

0.83

0.83

0.83

0.84

0.85

0.85

0.84

0.84

0.85

0.84

0.86

0.87

0.85

0.86

18.2

21.2

28.8

34.0

40.7

53.4

68.1

81.6

98.5

129

155

191

217

226

277

337

416

537

598

7.5

7.5

7.5

7.5

7.5

7.5

6.8

6.8

7.0

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

60.0

71.0

96.9

119.2

141.8

192.9

238.3

290.0

354.2

485

581

707

803

848

1029

1286

1607

2024

2281

3.0

2.9

3.0

2.8

3.0

3.0

2.9

2.7

3.0

2.6

2.6

2.5

2.5

2.5

2.6

2.6

2.5

2.5

2.5

4.0

3.8

3.9

3.3

3.5

3.3

3.2

3.1

3.4

2.8

2.8

2.8

2.8

2.8

2.9

2.8

3.0

3.0

3.0

0.105

0.110

0.135

0.219

0.243

0.385

0.427

0.525

0.694

1.495

1.725

2.988

3.887

3.887

4.637

5.03

8.502

10.115

11.065

130

134

159

192

205

259

274

307

358

690

750

1030

1175

1175

1350

1420

1915

2285

2430

0.37

0.55

0.75

1.1

1.5

2.2

3.7

5.5

7.5

1435

1430

1445

1435

1431

1450

1455

1464

1467

73.0

78.0

82.5

84.1

85.3

86.7

88.4

89.6

90.4

69.8

77.4

81.1

83.7

85.2

86.9

88.5

90.6

90.9

62.7

73.8

77.1

81.0

82.9

85.1

87.0

89.2

90.3

0.65

0.72

0.70

0.73

0.75

0.76

0.77

0.80

0.80

1.08

1.36

1.81

2.5

3.3

4.6

7.6

10.7

14.4

4.6

5.3

4.5

5.5

6.0

6.8

7.0

6.3

6.1

2.5

3.7

5.0

7.4

10.1

14.5

24.4

36.1

49.2

2.7

2.7

3.5

3.3

3.5

3.1

3.5

2.2

2.2

3.0

2.8

3.9

3.7

3.9

3.7

3.9

3.0

3.5

0.00082

0.00195

0.00309

0.00397

0.00486

0.00919

0.01540

0.03510

0.04110

10

15

20

22

25

34

50

72

84

M2BAX71MC4

M2BAX80MC4

M2BAX80MLA4

M2BAX90SB4

M2BAX90SLA4

M2BAX100LB4

M2BAX112MLA4

M2BAX132SMA4

M2BAX132MLA4

Page 18: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

General performance IE3 efficiency cast iron motorsTechnical data for totally enclosed squirrelcage three phase induction motors

IE3

IP 55 - lC 411 - Insulation class F, temperature rise class B

IE3 efficiency class according to IEC 60034-30-1; 2014

Efficiency values are given according to IEC 60034-2-1; 2014.Please note that the values are not comparable without knowing the testing method.ABB has calculated the efficiency values according to indirect method, stray load losses(additional losses) determined from measuring.

l / ls n

T / Ts n

T / Tb n

=

=

=

Starting current

Locked rotor torque

Breakdown torque

ABB Motors and Generators I Low voltage general performance IE3 efficiency motors6

7.5

9.3

11

15

18.5

22

30

37

45

55

75

90

110

125

132

160

200

250

315

972

977

977

979

988

989

989

990

988

988

989

990

990

990

988

989

990

988

990

89.1

89.8

90.3

91.2

91.7

92.2

92.9

93.3

93.7

94.1

94.6

94.9

95.1

95.2

95.4

95.6

95.8

95.8

95.8

90.2

90.3

91.0

91.6

91.8

92.2

93.0

93.7

93.7

94.1

94.6

94.9

95.1

95.2

95.4

95.6

95.8

95.8

95.8

90.0

89.7

90.7

91.0

90.9

91.1

92.0

93.4

91.7

92.1

92.6

92.9

93.1

93.2

93.4

93.6

93.8

93.8

93.8

0.75

0.75

0.74

0.77

0.81

0.81

0.78

0.82

0.84

0.84

0.84

0.84

0.84

0.84

0.84

0.84

0.85

0.84

0.84

15.7

20.3

22.9

30.3

34.5

41.6

59.2

68.0

80

97

131

157

192

217

229

277

342

432

545

6.5

6.0

6.0

5.0

7.0

7.5

7.0

6.0

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

7.7

73.3

90.7

107.5

146.2

178.6

212.2

290.3

356.6

435

532

724

868

1061

1206

1276

1545

1929

2416

3039

2.1

2.0

1.8

1.5

2.4

2.6

2.6

2.3

2.3

2.5

2.5

2.5

2.6

2.5

2.2

2.6

2.5

2.3

1.4

3.1

3.1

2.8

2.6

3.1

3.6

3.4

2.5

2.6

2.6

2.6

2.8

2.8

2.7

2.5

2.8

2.8

2.6

2.8

0.089

0.128

0.138

0.212

0.496

0.585

0.724

1.300

2.3

2.45

4.725

5.425

7.425

7.05

8.05

10.925

12.625

13.75

15.975

119

153

160

190

238

263

285

379

655

680

925

1010

1230

1305

1305

1670

1820

1975

3000

M2BAX160MLA6

M2BAX160MLJ6

M2BAX160MLB6

M2BAX160MLA6

M2BAX200MLA6

M2BAX200MLB6

M2BAX225SMA6

M2BAX250SMA6

E3HX280SMA6

E3HX280SMB6

E3BA315SMA6

E3BA315SMB6

E3BA315SMC6

E3BA315MLC6K

E3BA315MLC6

E3BA355SMA6

E3BA355SMB6

E3BA355MLA6

E3BA355MLB6

M2BAX80MC6

M2BAX80MLA6

M2BAX90SLA6

M2BAX90LB6

M2BAX100LKA6

M2BAX112MLA6

M2BAX132SMB6

M2BAX132MLA6

0.37

0.55

0.75

1.1

1.5

2.2

3.7

5.5

931

941

948

951

954

957

967

970

71.9

75.9

78.9

81.0

82.5

84.3

86.5

88.0

70.6

74.9

77.5

79.7

82.6

84.4

87.0

88.3

65.6

70.4

73.2

75.4

80.2

82.5

86.0

87.3

0.65

0.64

0.62

0.62

0.67

0.67

0.69

0.69

1.10

1.58

2.1

3.0

3.8

5.4

8.6

12.6

3.9

4.4

3.9

3.1

4.1

4.6

4.7

4.7

3.8

5.6

7.6

11.2

15.2

22.2

37.0

54.7

2.5

3.1

2.5

3.3

2.2

2.1

1.6

1.6

2.8

3.3

3.0

3.6

2.4

2.7

2.7

2.8

0.00220

0.00349

0.00487

0.00676

0.00994

0.01390

0.03540

0.05330

15

19

25

30

37

47

72

97

Output

KWFrame Size

Speed

r/min

Efficiency

Full

load

100%

3/4

load

75%

1/2

load

50%

Power

factor

cos Ø

Current TorqueMoment of

inertia2J=1/4GD

2kgm

Weightkg

l , An l / ls n T , Nmn T / Ts n T / Tb n

1000 r/min 415V, 50Hz

Page 19: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

General performance IE3 efficiency cast iron motorsDimension drawings

Foot-mounted motor IM1001, B3 Flange-mounted motor IM3001, B5

Size 71 to 200 Size 225 to 355

ABB Motors and Generators I Low voltage general performance IE3 efficiency motors 7

Motor

Size

D

Poles

GA

Poles

F

Poles

E

Poles

L max

Poles A B C HD K H MB' N P S T

2 4-6 2 4-6 2 4-6 2 4-6 2 4-6

Process performance cast iron motors

160ML

180ML

200ML

225SM

250SM

280SM

315SM

315ML

355SM

355ML

42

48

55

55

60

65

65

65

75

75

42

48

55

60

65

75

80

90

100

100

45

51.5

59

59

64

69

69

69

79.5

79.5

45

51.5

59

64

69

79.5

85

95

106

106

12

14

16

16

18

18

18

18

20

20

12

14

16

18

18

20

22

25

28

28

110

110

110

110

140

140

140

140

140

140

110

110

110

140

140

140

170

170

210

210

1639

728

809

812

853

1040

1169

1215

1504

1610

1639

728

809

842

853

1040

1245

1325

1574

1680

254

279

318

356

406

457

508

508

610

610

210

241

267

286

311

368

406

457

500

560

254

279

305

311

349

419

457

508

560

630

108

121

133

149

168

190

216

216

254

254

414

454

515

560

613

728

872

872

965

965

14.5

14.5

18.5

18.5

24

24

28

28

28

28

160

180

200

225

250

280

315

315

355

355

300

300

350

400

500

500

600

600

740

740

250

250

300

350

450

450

550

550

680

680

350

350

400

450

550

550

660

660

800

800

18.5

18.5

18.5

18.5

18.5

19

24

24

24

24

5

5

5

5

5

5

6

6

6

6

Above table gives the main dimensions in mm. 1) M2BAX 160ML C2, B4, B6: L = 696

71

80M

80ML

90S

90SL

90L

100L

100LK

112M

112ML

132SM

132ML

14

19

19

24

24

24

28

28

28

28

38

38

14

19

19

24

24

24

28

28

28

28

38

38

16

21.5

21.5

27

27

27

31

31

31

31

41

41

16

21.5

21.5

27

27

27

31

31

31

31

41

41

5

6

6

8

8

8

8

8

8

8

10

10

5

6

6

8

8

8

8

8

8

8

10

10

30

40

40

50

50

50

60

60

60

60

80

80

30

40

40

50

50

50

60

60

60

60

80

80

257

309

334

335

351

386

376

410

411

456

521

586

257

309

334

335

351

386

376

410

411

456

521

586

112

125

125

140

140

140

160

160

190

190

216

216

90

100

100

100

100

-

140

140

140

140

140

178

-

-

112

-

125

125

-

160

-

159

178

203

45

50

50

56

56

56

63

63

70

70

89

89

175

192

192

217

217

217

240

240

252

252

301

301

7

10

10

10

10

10

12

12

12

12

12

12

71

80

80

90

90

90

100

100

112

112

132

132

130

165

165

165

165

165

215

215

215

215

265

265

110

130

130

130

130

130

180

180

180

180

230

230

160

200

200

200

200

200

250

250

250

250

300

300

10

12

12

12

12

12

14.5

14.5

14.5

14.5

14.5

14.5

3.5

3.5

3.5

3.5

3.5

3.5

4

4

4

4

4

4

L

Page 20: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

General performance IE3 cast iron motors in brief

Size

Stator

Bearing end shields

Bearings

Axially-locked

Bearing seals

Lubrication

Terminal Box

Connections

Fan

Fan Cover

Stator winding

Rotor winding

Balancing method

Key ways

Enclosure

Cooling method

Material Cast Iron Grade 150:ISO 185

Paint colour shade Munsell blue 8B 4.5/3.25 / NCS 4822 B05G

Corrosion class C3 medium according to ISO / EN 12944-5

Material Cast iron grade 150 : ISO 185

Paint colour shade Munsell blue 8B 4.5/3.25/NCS 4822 B05G

Corrosion class C3 medium according to ISO / EN 12944-5

D-end 6203-2Z/C3 6204-2Z/C3 6205-2Z/C3 6206-2Z/C3 6206-2Z/C3 6208-2Z/C3

N-end 6202-2Z/C3 6203-2Z/C3 6204-2Z/C3 6205-2Z/C3 6205-2Z/C3 6208-2Z/C3

Retaining ring As standard , locked at D-end

Axial seal as standard, radial on request

Permanently lubricated shielded bearings

Not included

Material Aluminum

Frame material Cast iron, integral to Stator frame

Cover material Sheet of Steel, cold rolled

Cover screws material Steel 8.8

Cable entries 2xM16 2xM25

Terminals 6 terminals for connection with cable lugs (not included)

Cable gland Suitable opening in terminal box, cable glands as option

Material Polypropylene, Reinforced with 20% glass fibre

Material Sheet of steel, cold rolled

Paint Colour shade Munsell blue 8B 4.5/3.25/NCS 4822 B05G

Corrosion class C3 medium according to ISO/EN 12944-5

Material Copper

Insulation Insulation class F, Temperature rise class B unless otherwise stated.

Winding protection 3 PTC thermistors as option

Material Pressure diecast aluminum

Half Key Balancing as Standard

Open Key Way

IP 55, Higher protection on request

IC 411

71 80 90 100 112

Measuring nipple

Rating plate

ABB Motors and Generators I Low voltage general performance IE3 efficiency motors 8

132

2xM32

Page 21: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

General performance IE3 cast iron motors in brief

Size

Stator

Bearing end shields

Bearings

Axially-locked

Bearing seals

Lubrication

Terminal Box

Connections

Fan

Fan Cover

Stator winding

Rotor winding

Balancing method

Key ways

Enclosure

Cooling method

Material Cast Iron Grade 200:ISO 185

Paint colour shade Munsell blue 8B 4.5/3.25 / NCS 4822 B05G

Corrosion class C3 medium according to ISO / EN 12944-5

Material Cast iron grade 200 : ISO 185

Paint colour shade Munsell blue 8B 4.5/3.25/NCS 4822 B05G

Corrosion class C3 medium according to ISO / EN 12944-5

D-end 6209-2Z/C3 6210-2Z/C3 6212-2Z/C3 6213-2Z/C3 6215-2Z/C3

N-end 6209-2Z/C3 6209-2Z/C3 6209-2Z/C3 6210-2Z/C3 6212-2Z/C3

Inner Bearing Cover As standard , locked at D-end

Axial seal standard, radial on request

Permanently lubricated shielded bearings

Not included

Material Aluminum

Frame material Sheet of Steel, cold rolled

Cover material Sheet of Steel, cold rolled

Cover screws material Steel 8.8

Cable entries 2xM40, 1xM16 2xM50, 1xM16

Terminals 6 terminals for connection with cable lugs (not included)

Cable gland Suitable opening in terminal box, cable glands as option

Material Polypropylene, Reinforced with 20% glass fibre

Material Sheet of steel, cold rolled

Paint Colour shade Munsell blue 8B 4.5/3.25/NCS 4822 B05G

Corrosion class C3 medium according to ISO/EN 12944-5

Material Copper

Insulation Insulation class F, Temperature rise class B unless otherwise stated.

Winding protection 3 PTC thermistors as option

Material Pressure diecast aluminum

Half Key Balancing as Standard

Open Key Way

IP 55, Higher protection on request

IC 411

160 180 200 225 250

Measuring nipple

Rating plate

ABB Motors and Generators I Low voltage general performance IE3 efficiency motors 9

Page 22: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

Rotor winding

Balancing method

Key ways

Enclosure

Cooling method

Size2802-6 Pole

Stator

Bearing end shields

Bearings

Axially-locked

Bearing seals

Lubrication

Terminal Box

Connections

Fan Cover

Material Cast Iron Grade 150, ISO: 210

Paint colour shade Munsell blue 8B 4.5/3.25 / NCS 4822 B05G

Surface Treatment C3 medium according to ISO / EN 12944-5

Material Cast iron grade 150, ISO: 210

Paint colour shade Munsell blue 8B 4.5/3.25 / NCS 4822 B05G

Surface Treatment C3 medium according to ISO / EN 12944-5

D-end 6316/C3 6316/C3 6319/C3 6319/C3 6322/C3

N-end 6315/C3 6316/C3 6316/C3 6319/C3 6319/C3

Inner Bearing Cover As standard, locked at D-end

Radial as standard, on D-end only

Regreasable bearing, Regreasing nipple M10x1

-

Material Steel

Frame material Cast iron grade 150, ISO: 210

Cover material Cast iron grade 150, ISO: 210

Screws Steel

Threaded 2 x 2” BSC 2 x 2-1/2” BSC

Terminals 6 terminals for connection with cable lugs (not included)

Cable gland Cable flanges as standard, cable glands as option

Material PP* Aluminium

Material Sheet of steel, Cold Rolled

Paint Colour shade Munsell blue 8B 4.5/3.25 / NCS 4822 B05G

Surface Treatment C3 medium according to ISO / EN 12944-5

Material Copper

Insulation Insulation class F, Temperature rise class B unless otherwise stated.

Winding protection -

Material Pressure diecast aluminum

Half Key Balancing as Standard

Open Key Way

IP 55

IC 411

3152 Pole

3154-6 Pole

3552 Pole

3554-6 Pole

Measuring nipple

Rating plate

Fan

Stator winding

*Polypropylene, Reinforced with 20% glass fibre.

General performance IE3 cast iron motors in brief

ABB Motors and Generators I Low voltage general performance IE3 efficiency motors 10

Page 23: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

ABB Motors and Generators I Low voltage general performance IE3 efficiency motors 11

Page 24: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

www.abb.co.in

South

No. 49, 5th Floor, West Wing, Khanija Bhawan, Race Course Road, Bangalore 560 001Tel: +91 80 22949250 / 6677

ChennaiIst Floor, "Prestige Palladium Bayen", Opp. BSNL Shop No. 129-140, Greams Road,Chennai 600008Tel.: +91 44 4222829 / 550 / 551

CoimbatoreTel: +91 422 2305934Fax: +91 422 2300371

HyderabadTel: +91 40 27906736 / 29Fax: +91 40 27906648

KochiTel: +91 484 2421481

VisakhapatnamTel: +91 891 2795837Fax: +91 891 2538188

ABB India Limited32, Industrial Area,N.I.T., Faridabad - 121 001Tel: +91 129 2448100Fax: +91 129 4023006Helpline No. : 1800 425 0707

Regional Marketing Offices :

North

14, Mathura Road,Faridabad - 121 003Tel: +91 129 - 2275592/9627Fax: +91 129 - 2275019

ChandigarhUnit No. 513, 5th Floor, C-WingElante Office : Plot No. 178-178AIndustrial Area, Phase - I ChandigarhTel: +91 172 5214400

Jaipur204-205, IInd Floor, North WingKailash Tower, Gandhi Nagar ModTonk Road, JaipurTel: +91 141 2744023-24

LucknowTel: +91 522 2209436Fax: +91 522 2209478

LudhianaTel: +91 161 4656831Fax: +91 161 4656830

DehradunTel: +91 135 2760654Fax: +91 135 2760655

East

Omega Building, 17th Floor,Bengal Intelligent Park,Block EP & GP, Sector V,Salt Lake City, Kolkata 700 091Tel: +91 33 66213135Fax: +91 33 66213187

JamshedpurKashikunj Building, Road No. 2, Bistpur Jamshedpur - 831011Tel: +91 657 6619201

Raipur4th & 5th Floor, Maruti HeightsAamanaka, G.E. Road,Raipur - 492 099Tel: +91 771 4213200Fax: +91 771 4213222

Bhubaneshwar1st Floor, Plot no. A-51/1, Bhoi Nagar, Sachivaiya Marg, Unit-9, BhubaneshwarTel.: +91 674654/8701 - 715

West

ABB HouseDr. S B PathBallard Estate, Mumbai 400 038Tel: +91 22 66159888Fax: +91 22 66314203

BhopalPlot No. 34, Sector A, Near Bhopal Medical Centre, Indrapuri, Bhopal 462 021Tel: +91 755 6463603

PuneTel: +91 20 66243838Fax: +91 20 66016255

VadodaraTel: +91 265 2642141-42Fax: +91 265 2638911

NagpurTel: +91 712 6461145, 46, 48, 49Fax: +91 712 2290283

IndoreTel: +91 9981146044

Note:

We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.

We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its content - in whole or in parts - is forbidden without ABB's prior written consent.

CA

T-1

1 15/0

3/2

016

Page 25: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

Flame Proof Motors For Hazardous Environment

JHX

Page 26: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

Introduction

The use of electrical motors in potentially explosive atmospheres is quite frequent these days. These motors have to be constructed in such a way that there is no risk of an explosion. An Explosion occurs when the following situations occur:

- presence of potentially explosive atmosphere

- existence of a source of ignition

- possibility of transmission of the explosion

Classification of Hazardous Environment:

According to IS: 5572, Hazardous areas are classified in the following ways depending on the degree of probability of the presence of hazardous atmosphere.

Zone 2Abnormal ConditionsPresence of explosive atmosphereonly by accident, but not during normalduty ( 10 H per year)

Zone 1Occasionally Incidental presence of explosive atmosphere during normal duty(10 - 1000 H per year)

Zone 0Continuously Permanent presence of explosive atmosphere ( > 1000 Hper year)

Zone Criteria presence of gas

Zone 0 Continuously of very long period

Zone 1 Present in normal operations

Zone 2 Unlikely, but if present, only for a short time

In Zone 0, no electrical motors can be installed. Most common motor for Zone 1 is the flameproof design, but it can also be used in Zone 2.

Application Groups:

Depending on the intended use, explosion-proof electrical operating equipment is divided into two major groups:

Group I Equipment for coal mines (only specially designed motors for mines can be used)

Group II Electrical equipment for use other than mines (surface industry)

Group II motors with flameproof enclosures are still further divided into gas groups:

II A Propane

II B Ethylene

II C Hydrogen

Temperature Classes:

Combustible gas or vapour and explosion-protected electrical equipment are divided into temperature of the gas or to T6 with regard to the ignition temperature of the gas or vapour and the maximum surface temperature of the component.

Flame proof motors, type "d"

ABB motors of flame proof design (type JHX) are TEFC, 3 phase squirrel

cage induction motor (as per IS:2148 - 2004) for operation in hazardous

location classified as Zone 1 and Zone 2 areas as per IS:5572

Note: Other frame sizes are available on request.

The motor enclosure has been designed in such a way that no internal

explosion can be transmitted to the explosive atmosphere surrounding the

machine. The enclosure must withstand, without damage, any pressure

levels caused by an internal explosion, the shape, length and gap of part

assembly joints at shaft opening, cable entries, etc.., shall be designed to

allow for throttling and cooling of hot gases escaping outside. The standard

emphasise the impact of an explosive atmosphere

(for instance, explosion pressure) over constructional requirements of such

apparatus.

Range:0.25 ....... 15kW, 0.33 .....20hp

Frame:JHX71 .....JHX160

Pole:2 .....8

Features:

1. Motors suitable for high ambient temperature 50ºC.

2. Keeps an explosion which takes place inside the enclosure

from propagating through gaps to the ambient.

3. Withstands the explosion pressure created inside

the enclosures.

4. Benefits when dealing with special operating modes such as heavy

stars and special applications.

5. All surface temperatures are selected to comply with the temperature

class.

6. Suitability for use in temperature classes T1 toT4.

7. Can be used both in Zone 1 and Zone 2.

Temperature Ignition Maximum permittedclass temperature temperature of

for the gas / electricalvapour °C equipment °C

T1 >450 450

T2 >300 <450 300

T3 >200 <300 200

T4 >135 <200 135

T5 >100 <135 100

T6 >85 <100 15

Page 27: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

TEFC, S1 Duty

415 ± 10% V, 50 ± 5%Hz.

Combined Variation of ±10%

0Insulation Class F, Ambient Temp. = 50 C

0Temperature rise class B (70 C)

Gas Group IIA & IIB

0.37

0.55

0.75

1.1

1.5

2.2

3.7

5.5

7.5

9.3

11.0

15.0

18.5

0.50

0.75

1.0

1.5

2.0

3.0

5.0

7.5

10.0

12.5

15.0

20.0

25.0

0.9

1.3

1.7

2.5

2.9

4.2

7.2

10.0

13.5

16.0

20.0

26.0

32.0

66.0

68.0

73.0

76.0

81.0

81.5

80.0

84.0

86.0

86.5

88.0

89.0

91.0

68.0

66.0

72.0

74.0

81.0

81.5

79.5

84.0

86.0

86.5

88.0

89.0

91.0

64.0

60.0

68.0

71.0

77.0

77.5

77.5

83.0

85.0

85.5

87.0

88.0

90.0

0.84

0.82

0.90

0.88

0.90

0.90

0.87

0.88

0.90

0.91

0.87

0.87

0.90

0.77

0.75

0.84

0.81

0.84

0.84

0.84

0.86

0.88

0.89

0.85

0.85

0.87

0.50

0.64

0.74

0.70

0.74

0.74

0.74

0.83

0.85

0.86

0.82

0.82

0.84

4.2

4.3

4.8

5.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

2.0

2.0

2.1

2.1

2.2

2.1

2.2

2.1

2.4

2.5

2.2

2.2

2.5

2.4

2.5

2.3

2.4

3.0

3.0

2.7

3.0

3.0

3.0

2.8

3.0

2.9

1.3

1.9

2.6

3.8

5.0

7.3

12.5

18.3

25.0

30.9

36.2

49.4

60.9

5

5

7

7

5

6

6

7

7

9

12

12

12

12

12

16

16

10

12

12

14

14

20

28

28

28

2790

2790

2780

2790

2865

2865

2830

2870

2870

2870

2900

2900

2900

JHX71C2

JHX71D2

JHX80C2

JHX80D2

JHX90SLC2

JHX90SLD2

JHX100LB2

JHX132SMB2

JHX132SMC2

JHX132SME2

JHX160MLB2

JHX160MLD2

JHX160MLE2

2 Pole

Output RatedSpeed (rpm)Frame Size Power FactorEfficiency %

In(A) FLFLkW HP 3/4FL3/4FL 1/2FL1/2FL/I Is n (Sec)Thot

(Sec)Tcold

Nm)T (n

Torque/ /T TT Ts maxn n

Current(A)

17

17

21

22

33

35

55

83

92

100

139

151

164

WeightKg

Gd2Kgm2

0.001

0.002

0.003

0.004

0.008

0.009

0.044

0.052

0.072

0.092

0.128

0.152

0.182

0.25

0.37

0.55

0.75

1.1

1.5

2.2

3.7

5.5

7.5

9.3

11

15

0.33

0.50

0.75

1.00

1.5

2.0

3.0

5.0

7.5

10

12.5

15

20

0.7

1.1

1.5

2.0

2.5

3.4

4.8

7.6

11.0

14.5

18.8

21.0

28.0

63.0

64.0

65.0

68.0

76.0

77.0

78.0

83.0

85.0

85.5

88.0

89.0

89.0

61.0

62.0

64.0

67.0

76.0

77.0

78.0

83.0

85.0

85.5

88.0

89.0

89.0

55.0

56.0

60.0

62.0

74.0

75.0

76.0

81.0

83.0

83.5

86.0

87.0

87.0

0.80

0.80

0.76

0.76

0.80

0.81

0.81

0.81

0.82

0.83

0.81

0.82

0.82

0.68

0.68

0.65

0.65

0.71

0.73

0.73

0.74

0.75

0.76

0.74

0.76

0.76

0.54

0.54

0.52

0.52

0.56

0.62

0.62

0.63

0.64

0.64

0.63

0.66

0.66

3.5

3.5

3.5

3.5

5.5

5.5

5.5

6.0

6.0

6.0

6.0

6.0

6.0

1.9

2.0

2.0

2.0

2.0

2.0

2.2

2.1

2.0

2.0

2.2

2.1

2.1

2.4

2.4

2.4

2.4

2.7

2.7

2.7

2.8

2.8

2.8

2.8

2.8

2.8

1.7

2.6

3.8

5.2

7.4

10.1

15.0

24.8

36.7

50.1

61.0

72.2

98.8

7

7

6

5

5

5

5

5

7

8

8

12

14

16

16

14

12

10

12

12

14

16

16

18

28

30

1370

1370

1400

1380

1420

1420

1405

1425

1430

1430

1455

1455

1450

JHX71B4

JHX71C4

JHX80D4

JHX80E4

JHX90SLD4

JHX90SLE4

JHX100LB4

JHX112MB4

JHX132SMC4

JHX132SME4

JHX160MLB4

JHX160MLD4

JHX160MLE4

4 Pole

Output RatedSpeed (rpm)Frame Size Power FactorEfficiency %

In(A) FLFLkW HP 3/4FL3/4FL 1/2FL1/2FL/I Is n (Sec)Thot

(Sec)Tcold

Nm)T (n

Torque/ /T TT Ts maxn n

Current(A)

16

17

21

22

34

36

55

67

91

99

138

151

162

WeightKg

Gd2Kgm2

0.003

0.004

0.007

0.008

0.015

0.017

0.026

0.050

0.088

0.112

0.028

0.252

0.272

I = Nominal or rated currentn2T = Nominal or rated torque in Nm T = Starting torque 2. Max. load GD has been calculated assuming load n s

T = Maximum torque T = Hot withstand time torque is proportional to square of speed.max hot

T = Cold withstand timecold

I = Starting current Note : 1. All performance figures are subject to IS tolerances.s

0.25

0.37

0.55

0.75

1.1

1.5

2.2

3.7

5.5

7.5

9.3

11

0.33

0.50

0.75

1.0

1.5

2.0

3.0

5.0

7.5

10

12.5

15

0.7

1.0

1.5

2.0

2.9

4.0

5.9

8.3

12.2

15.5

19.0

23.0

64.0

67.0

66.0

73.0

74.0

75.5

78.5

83.0

83.5

87.5

88.0

88.0

62.0

65.0

64.0

73.0

74.0

75.5

78.5

83.0

83.5

87.5

88.0

88.0

58.0

61.0

60.0

70.0

71.0

72.5

76.5

81.0

81.5

86.5

86.0

86.0

0.73

0.73

0.73

0.70

0.70

0.70

0.70

0.70

0.72

0.77

0.77

0.77

0.65

0.65

0.65

0.60

0.60

0.61

0.61

0.66

0.68

0.72

0.72

0.72

0.52

0.52

0.52

0.52

0.52

0.52

0.54

0.54

0.62

0.60

0.60

0.60

3.5

3.5

3.5

3.5

3.5

4.5

5.0

5.5

5.5

5.5

6.0

6.0

1.8

2.1

1.9

1.8

1.8

2.2

2.0

2.2

2.2

1.9

2.0

2.0

2.0

2.4

2.2

2.1

2.1

2.5

2.5

2.6

2.6

2.5

2.5

2.5

2.7

4.0

6.0

7.8

11.2

15.3

21.9

36.8

54.4

74.6

92.0

109.0

10

10

10

10

12

10

10

8

10

8

8

9

24

24

24

24

25

24

20

19

20

18

18

20

880

885

880

915

915

935

940

955

955

960

965

965

JHX80D6

JHX80D6

JHX80E6

JHX90SLD6

JHX90SLE6

JHX100LB6

JHX112MB6

JHX132SMC6

JHX132SME6

JHX160MLC6

JHX160MLD6

JHX160MLE6

6 Pole

Output RatedSpeed (rpm)Frame Size Power FactorEfficiency %

In(A) FLFLkW HP 3/4FL3/4FL 1/2FL1/2FL/I Is n (Sec)Thot

(Sec)Tcold

Nm)T (n

Torque/ /T TT Ts maxn n

Current(A)

WeightKg

Gd2Kgm2

0.008

0.008

0.009

0.015

0.017

0.026

0.050

0.088

0.120

0.326

0.372

0.446

0.37

0.55

0.75

1.1

1.5

2.2

3.7

5.5

7.5

0.50

0.75

1.0

1.5

2.0

3.0

5.0

7.5

10.0

1.4

1.9

3.1

3.9

4.8

6.3

8.0

12.0

16.0

58.0

63.0

63.0

62.5

69.0

77.0

82.5

84.5

85.0

55.0

60.0

62.0

62.0

67.0

76.0

82.5

83.5

84.0

48.0

54.0

57.0

57.0

63.0

71.0

79.5

81.5

82.0

0.65

0.63

0.56

0.59

0.60

0.65

0.77

0.79

0.79

0.55

0.55

0.50

0.51

0.51

0.55

0.70

0.72

0.72

0.40

0.40

0.37

0.38

0.41

0.42

0.55

0.59

0.59

2.8

3.2

3.0

3.0

3.5

4.1

5.1

5.1

5.1

1.6

1.8

1.8

1.8

1.8

1.9

1.8

1.8

1.8

1.9

2.1

2.1

2.3

2.3

2.4

2.4

2.5

2.5

5.20

7.70

10.3

15.1

20.5

29.6

49.4

73.5

98.8

10

10

10

10

9

8

9

13

15

24

24

24

24

20

19

20

29

30

680

680

695

695

700

710

715

715

715

JHX90SLA8

JHX90SLD8

JHX100LA8

JHX100LB8

JHX112MA8

JHX132SMB8

JHX160MLB8

JHX160MLD8

JHX160MLE8

8 Pole

Output RatedSpeed (rpm)Frame Size Power FactorEfficiency %

In(A) FLFLkW HP 3/4FL3/4FL 1/2FL1/2FL/I Is n (Sec)Thot

(Sec)Tcold

Nm)T (n

Torque/ /T TT Ts maxn n

Current(A)

30

34

50

55

64

83

137

149

161

WeightKg

Gd2Kgm2

0.012

0.015

0.02

0.026

0.044

0.06

0.288

0.372

0.446

21

22

23

34

36

55

67

90

98

142

150

162

Not

e : O

win

g to

con

tinuo

us u

pgra

datio

n of

our

des

ign,

per

form

ance

par

amet

ers

and

dim

ensi

ons

are

subj

ect t

o ch

ange

with

out p

rior

not

ice.

Page 28: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

Dim

en

sio

n D

raw

ing

Fo

ot

Mo

un

ted

Fla

me

Pro

of

Mo

tors

71

....1

60

Mo

un

tin

g D

es

ign

ati

on

B3

, B

6, B

7, B

8, V

5, V

6D

ime

ns

ion

Dra

win

g F

lan

ge

Mo

un

ted

Fla

me

Pro

of

Mo

tors

71

....1

60

Mo

un

tin

g D

es

ign

ati

on

B5

, V

1, V

3

Ea

rth

ing

scr

ew

M6

fo

r JH

X7

1-1

12

Ea

rth

ing

scr

ew

M1

0 fo

r JH

X1

32

, 1

60

øD

Ea

rth

ing

scr

ew

M6

fo

r JH

X7

1-1

12

Ea

rth

ing

scr

ew

M1

0 fo

r JH

X1

32

, 1

60

øD

Ty

pe

JHX

71

JHX

80

JHX

90

SL

JHX

10

0L

JHX

11

2M

JHX

13

2S

M

JHX

16

0M

L

112

12

5

14

0

16

0

19

0

21

6

25

4

A

25

25

27

42

48

48

60

13

0

14

7

16

2

20

0

23

0

25

6

31

0

AA

AB

14

0.5

15

8

17

4

20

3

22

5

25

8

30

5

90

10

0

10

0

14

0

14

0

14

0

21

0

- -

12

5 - -

17

8

25

4

26

30

40

47

47

47

65

110

12

6

15

8

18

0

18

0

21

8

31

0

AC

B

B'

BA

BB

45

50

56

63

70

89

10

8

C

30

40

50

60

60

80

110

M5

M6

M8

M1

0

M1

0

M1

2

M1

6

12

17

19

22

22

28

36

16

24

32

42

42

60

90

EE

BE

CE

KTy

pe

JHX

71

JHX

80

JHX

90

SL

JHX

10

0L

JHX

11

2M

JHX

13

2S

M

JHX

16

0M

L

AC

14

0.5

15

8

17

4

20

3

22

5

25

8

30

5

14

7

15

4

16

2

21

7

22

5

24

2

29

7

AD

30

40

50

60

60

80

110

E

M5

M6

M8

M1

0

M1

0

M1

2

M1

6

EB

12

17

19

22

22

28

36

EC

16

24

32

42

42

60

90

EK

5 6 8 8 8 10

12F

11 15

.5

20

24

24

33

37G

GD 5 6 7 7 7 8 8

Ty

pe

JHX

71

JHX

80

JHX

90

SL

JHX

10

0L

JHX

11

2M

JHX

13

2S

M

JHX

16

0M

L

5 6 8 8 8 10

12F

11 15

.5

20

24

24

33

37G

GD 5 6 7 7 7 8 8

H 71

80

90

10

0

112

13

2

16

0

9 10

13

15

18

20

22

HA

21

8

23

4

25

2

31

7

33

7

37

4

45

7

HD

K 7 10

10

12

12

12

15

L

26

8

31

4

36

3

40

0

42

0

511

70

2

Be

ari

ng

s

DN

62

03

ZZ

C3

62

04

ZZ

C3

62

05

ZZ

C3

63

06

ZZ

C3

63

07

ZZ

C3

63

08

ZZ

C3

63

09

ZZ

C3

62

02

ZZ

C3

62

03

ZZ

C3

62

05

ZZ

C3

62

06

ZZ

C3

62

06

ZZ

C3

63

07

ZZ

C3

63

08

ZZ

C3

Ty

pe

JHX

71

JHX

80

JHX

90

SL

JHX

10

0L

JHX

11

2M

JHX

13

2S

M

JHX

16

0M

L

26

8

31

4

36

3

40

0

42

0

511

70

2

L

9 10

10

11 11 12

16

LA

LB

23

8

27

4

31

3

34

0

36

0

43

1

59

2

M 13

0

16

5

16

5

21

5

21

5

26

5

30

0

110

13

0

13

0

18

0

18

0

23

0

25

0

N

16

0

20

0

20

0

25

0

25

0

30

0

35

0

PS 10

12

12

15

15

15

19

T 3.5

3.5

3.5 4 4 4 5

Be

ari

ng

s

DN

62

03

ZZ

C3

62

04

ZZ

C3

62

05

ZZ

C3

63

06

ZZ

C3

63

07

ZZ

C3

63

08

ZZ

C3

63

09

ZZ

C3

62

02

ZZ

C3

62

03

ZZ

C3

62

05

ZZ

C3

62

06

ZZ

C3

62

06

ZZ

C3

63

07

ZZ

C3

63

08

ZZ

C3

D

To

l.

14

19

24

28

28

38

42

j6 j6 j6 j6 j6 k6 k6

D

To

l.

14

19

24

28

28

38

42

j6 j6 j6 j6 j6 k6 k6

Page 29: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

Terminal Box

Type A B C D E F G H

JHX 71 - 90 20 20 10.5 50 27 M5 42 115

JHX 100-132 26 26 13.5 75 32 M6 66.5 160

JHX 160 32 32 12 95 39 M8 94 210

Certifications and Approvals for ABB Make Flame - Proof Motors

A/P/HQ/MH/104/1270 (P187868) Dt. 23.11.2006

CMRI/TC/P/H409 Dt. 28.08.2006

CIMFR/TC/P/60 Dt. 05.05.2009

CIMFR/TC/SR/H969 Dt. 19.02.2008ERTL(E)/TES/A356/0076/03-08Dt. 02/04/2008

A/P/HQ/MH/104/1856 (P233102/1)Dt. 15.06.2009

A/P/HQ/MH/104/1564 (P214909) Dt. 04.07.2008A/P/HQ/MH/104/1545 (P213402/1) Dt. 30.05.2008

CMRI/ERTL Certificate No. CCE Certificate No. DGFASLI Certificate No. BIS Certificate No. Frame

66/7/2009 - Tech Dt. 02.07.2009

66/07/2006 - TechDt. 15.11.200666/05/2005 - TechDt. 14.08.200866/05/2008 - TechDt. 09.06.2009

CM/L 1327946

CM/L 1327946

CM/L 1327946

CM/L 9342275

JHX80

JHX90

JHX100

JHX112

CIMFR/TC/P/113 Dt. 12.05.2009

A/P/HQ/MH/104/1889 (P234925/1) Dt 27.07.2009

66/7/2009 - Tech Dt. 02.07.2009

CM/L 1327946 JHX71

ERTL(E)/TES/A356/0077/03-08Dt. 02/04/2008

ERTL(E)/TES/A356/0075/03-08Dt. 02/04/2008

A/P/HQ/MH/104/1545 (P213402/2) Dt. 30.05.2008

A/P/HQ/MH/104/1545 (P213402/3) Dt. 30.05.2008

66/05/2008 - TechDt. 09.06.2009

66/05/2008 - TechDt. 09.06.2009

CM/L 9342275

CM/L 9342275

JHX132

JHX160

Earthing screw M6

* For JHX160, conduit entry is double

Page 30: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

South

Khanija Bhawan, 5th Floor, West Wing, 49, Race Course RoadBangalore - 560 001Tel: +91 80 22949250Fax: +91 80 22946702/03

Chennai'Janpriya Crest', I Floor 113/96 Pantheon Rd Egmore, Chennai 600008 Tel.: +91 44 28191551/28191661Fax: +91 44 28193545

CoimbatoreTel: +91 422 2305934Fax: +91 422 2300371

HyderabadTel: +91 40 27906736,29Fax: +91 40 27906648

KochiTel: +91 484 2330342Fax: +91 484 2370343

VisakhapatnamTel: +91 891 2795837Fax: +91 891 2538188

ABB Limited32, Industrial Area, N.I.T., Faridabad - 121 001 Tel: +91 129 2448100Fax : +91 129 4023006

Regional Marketing Offices :

North

14, Mathura Road,Faridabad - 121 003 Tel: +91 129 - 2275592/9627Fax: +91 129 - 2275019

ChandigarhSCO13, 14, 15, 3rd Floor, Sec. 34 A, ChandigarhTel: +91 172 4321800Fax: +91 172 2601618

JaipurTel: +91 141 2744024Fax: +91 141 2744027

LucknowTel: +91 522 2209436Fax: +91 522 2209478

LudhianaTel: +91 161 4656831Fax: +91 161 4656830

Dehradun Tel: +91 135 2760654Fax: +91 135 2760655

East

Omega Building, 17th Floor, Bengal Intelligent Park, Block EP & GP, Sector V, Salt Lake City, Kolkata 700 091Tel: +91 33 66213000 - 11Fax: +91 33 66213187

Raipur4th & 5th Floor, Maruti Heights Aamanaka, G.E. Road, Raipur - 492 099 Tel: +91 771 4213200Fax: +91 771 4213222

BhubaneshwarTel: +91 674 6616300 -11Fax: +91 674 6616307

JamshedpurTel: +91 657 6619204Fax: +91 657 6619200

GuwhatiTel: +91 361 2464260Mob: +91 9435731532

West

ABB HouseDr. S B PathBallard Estate, Mumbai 400 038Tel: +91 22 66159888Fax: +91 22 66314203

BhopalFF - 9A, Mansarovar,Commercial Complex Hosangabad Road, Bhopal 462016Tel: +91 755 4223572Fax: +91 755 4253323

PuneTel: +91 20 66243838Fax: +91 20 66016255

VadodaraTel: +91 265 2642141-42Fax: +91 265 2638911

AhemadabadTel: +91 79 66090111

NagpurTel: +91 712 6461145,46, 48, 49Fax: +91 712 2290283

IndoreTel: +91 9981123166

www.abb.co.in

CA

T-

04

R-1

27.

02.2

010

Page 31: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

eSt el

Power

ee

t

Cm

n

Ppaer

n

Cme

et

pr

Pae

M2BA M 2000 range

The most widely used motors from the world leaders

Page 32: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

I = Nominal or rated currentn2T = Nominal or rated torque in Nm T = Starting torque 2. Max. load GD has been calculated assuming load n s

torque is proportional to square of speed.T = Maximum torque T = Hot withstand timemax hot

T = Cold withstand timecold

Note : Owing to continuous upgradation of our design, performance parameters and dimensions are subject to change without prior notice.

I = Starting current Note : 1. All performance figures are subject to IS tolerances.s

* On request, motors of higher kw can be offered. # Class F rise

150167180200220240270340425475

95.095.395.395.695.695.896.096.096.196.2

95.095.395.395.695.695.896.096.096.196.2

0.870.880.890.900.900.900.900.900.910.90

0.830.850.860.870.870.870.870.870.880.87

0.750.780.800.810.810.810.810.810.820.81

1.92.02.02.32.22.72.61.51.51.7

2.72.82.73.03.03.23.03.03.03.2

352401423481513577641802

10101138

RatedSpeed (rpm)

Frame SizeIn

(A) I /Is nTn

Nm

M2BA315SMA2M2BA315SMB2KM2BA315SMB2M2BA315MLA2KM2BA315MLA2M2BA315MLC2KM2BA315MLC2M2BA355SMA2M2BA355MLA2M2BA355MLC2

2980298029802980298029802979297829782982

185206217243259290322403500570

110125132150160180200250315355

OutputkW HP

94.094.394.394.694.694.895.095.095.195.2

7.07.07.07.07.07.57.06.06.07.5

40404050505050607070

Thot

(Sec)Tcold

(Sec)

8383839898

102102115138138

WeightKg

875915915

1150115012751275164518952000

2Gd2Kgm

5.05.85.87.87.8

10.210.217.023.026.1

Efficiency % Power factorFL 3/4FL 1/2FL FL 3/4FL 1/2FL

TorqueT /Ts n T /Tmax n

150167180200220240250270335425475

95.295.495.595.895.895.895.896.096.196.396.5

95.295.495.595.895.895.895.896.096.196.396.5

0.860.870.870.870.870.870.870.880.870.870.87

0.820.830.830.830.830.830.830.850.830.820.82

0.740.750.750.750.750.750.750.790.750.730.73

2.01.82.02.12.02.02.02.22.02.51.5

2.72.62.72.82.72.72.72.82.63.02.7

707804849964

1029115712021286160620242281

4 Pole

RatedSpeed (rpm)

Frame SizeIn

(A) I /Is nTn

Nm

M2BA315SMA4M2BA315SMB4KM2BA315SMB4M2BA315MLA4KM2BA315MLA4M2BA315MLB4KM2BA315MLB4M2BA315MLC4M2BA355SMA4M2BA355MLA4M2BA355MLB4

14851485148514851485148514851485148614861486

187210221250267300312329416523588

110125132150160180187200250315355

OutputkW HP

94.294.494.594.894.894.894.895.095.195.395.5

6.06.06.06.06.06.06.06.06.07.06.5

3431313434323236605858

Thot

(Sec)Tcold

(Sec)

7063637070656575

122120120

WeightKg

905960960

11101110115011501260162018702110

2Gd2Kgm

9.510.610.613.513.515.615.617.026.533.040.0

Efficiency % Power factorFL 3/4FL 1/2FL FL 3/4FL 1/2FL

TorqueT /Ts n T /Tmax n

100120150167180220240270335425

94.294.594.694.794.995.295.395.595.695.6

94.294.594.694.794.995.295.395.595.695.6

0.850.840.840.840.850.850.840.840.850.84

0.810.790.790.790.800.800.790.790.800.80

0.720.700.700.700.710.710.700.700.710.71

2.02.32.32.42.32.02.02.52.32.5

2.52.72.72.72.72.73.02.82.72.8

726870

10631208127615451736192924163039

6 Pole

RatedSpeed (rpm)

Frame SizeIn

(A) I /Is nTn

Nm

M2BA315SMA6M2BA315SMB6M2BA315SMC6M2BA315SMC6KM2BA315MLC6M2BA355SMA6M2BA355SMB6KM2BA355SMB6M2BA355MLA6M2BA355MLB6

986988988988988989990990988990

132158193219228275313347428546

7590

110125132160180200250315

OutputkW HP

92.292.592.692.792.993.293.393.593.693.6

6.06.56.56.56.56.56.56.56.56.5

27212626245860605252

Thot

(Sec)Tcold

(Sec)

5543545450

120115115107107

WeightKg

860930

10051005124015951800180019402040

2Gd2Kgm

14.216.720.020.028.242.050.550.555.0

60.24

Efficiency % Power factorFL 3/4FL 1/2FL FL 3/4FL 1/2FL

TorqueT /Ts n T /Tmax n

75100120150180200220240270300335

93.594.094.594.694.795.095.095.295.395.395.5

93.594.094.594.694.795.095.095.295.395.395.5

0.810.820.820.820.810.800.800.740.760.770.79

0.730.750.750.750.730.720.720.660.680.690.71

0.610.650.650.650.610.610.600.540.540.550.57

1.71.81.91.81.51.81.81.91.71.81.6

2.52.52.52.52.32.72.53.02.62.72.6

710968

116114201704193620642323258129043226

8 Pole

RatedSpeed (rpm)

Frame SizeIn

(A) I /Is nTn

Nm

M2BA315SMA8M2BA315SMB8M2BA315SMC8M2BA315MLB8M2BA355SMA8M2BA355MLA8KM2BA355MLA8M2BA355MLB8IM2BA355MLB8M2BA355MLB8HM2BA355MLB8K

740740740740740740740740740740740

101135162197239274293358385426460

557590

110132150160180200225

250#

OutputkW HP

91.592.092.592.692.793.093.093.293.393.393.5

6.06.06.06.06.06.06.06.06.06.06.0

2930302432404070707070

Thot

(Sec)Tcold

(Sec)

59616149668282

150150150150

WeightKg

830975

105511251590194519452090209021002100

2Gd2Kgm

13.018.822.023.642.055.055.064.264.264.264.2

Efficiency % Power factorFL 3/4FL 1/2FL FL 3/4FL 1/2FL

TorqueT /Ts n T /Tmax n

2 Pole

TEFC, S1 Duty415 ± 10% V, 50 ± 5%Hz.Combined Variation of ±10%IP 55, IC 0141

Insulation Class F0 0Ambient 50 C (Temp. rise class B 70 C)

Page 33: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

Not

e : A

ll D

imen

sion

s ar

e in

mm

M2B

A31

5 (F

oot M

ount

ed)

Mou

ntin

g D

esig

natio

n B

3, IM

1001

M2B

A31

5 (F

lang

e M

ount

ed)

Mou

ntin

g D

esig

natio

n B

5, IM

3001

AA

AA

BA

CB

BA

BB

CD

TO

L.E

BE

508

508

B’

120

120

620

620

645

645

406

457

457

508

180

180

589

608

216

216

M20

2 P

ole

4-8

Pol

e

2 P

ole

4-8

Pol

e

65 80 65 90

m6

m6

m6

m6

140

170

140

170

M24

Type

M2B

A31

5SM

M2B

A31

5ML

EC

EK

FG

GD

HH

DK

LLD

Bea

ring

sO

HA

315

315

50 50

872

872

28 28

2 P

ole

4-8

Pol

e

2 P

ole

4-8

Pol

e

360.

539

0.5

360.

539

0.5

6316

C3

6319

C3

6316

C3

6319

C3

40 40 48

115

130

115

130

18 22 18 25

58 71 58 81

11 14 11 14

1169

1199

1215

1245

115

115

6316

C3

6316

C3

6316

C3

6316

C3

DN

Type

M2B

A31

5SM

M2B

A31

5ML

Type

AC

AD

EE

BE

CE

KG

D

TOL.

M2B

AF

315S

M

M2B

AF

315M

L

645

645

F

557

557

2 P

ole

4-8

Pol

e

2 P

ole

4-8

Pol

e

65 80 65 90

m6

m6

m6

m6

140

170

140

170

M20

M20

M24

40 40 48

115

130

115

130

18 22 18 25

58 71 58 81

GD

LLB

LA

11 14 11 14

1169

1199

1215

1245

22 22

1029

1075

Type

LDM

NP

ST

600

600

550

550

660

660

24 24

O 115

115

M2B

AF

315S

M

M2B

AF

315M

L

2 P

ole

4-8

Pol

e

2 P

ole

4-8

Pol

e

360.

539

0.5

360.

539

0.5

6 6

Bea

ring

s

6316

C3

6319

C3

6316

C3

6319

C3

6316

C3

6316

C3

6316

C3

6316

C3

DN

EB

EC

L

LD

TO

G

ØD

Ter

. Box

for

acce

ssor

ies

ELB

LA

EK

ØP

ØN –js6

ØAC

ØM

Ear

thin

g 2

–M10

L

O

BA B B’

BB

Ear

thin

c 2

– M

10

HA

AC

Ter

min

al B

ox fo

r ac

cess

orie

s(if

req

uire

d)

HDH– A

A

ABA

ØK

01

F –

h9

GD

G

ØD

EC

EB

LD

EK E

C

GDF –

h9

±0.

3

AD

45°

22.5°

Page 34: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

M2B

A35

5 (F

oot

Mou

nted

)M

2BA

355

(Fla

nge

Mou

nted

)

Not

e : A

ll D

imen

sion

s ar

e in

mm

M2B

A35

5MLC

2

EB

G

GD

HA

N-js6

AC

AD

G

GD

M2B

A35

5SM

L2P 4-8P

710

610

120

740

500

560

630

186

795

254

75m

614

0M

20

100

m6

210

M24

700

M2B

A35

5MLB

471

0

160

160

M2B

A35

5MLC

2

M2B

A35

5SM

L2P 4-8P

40

M2B

A35

5MLB

448

115

170

20 28

67.5

12

9016

355

33 55 33

985

965

28

1650

1575

1505

1575

465

395

130

6322

C3

6319

C3

6319

C3

6319

C3

--

Ty

pe

AA

AA

BA

CB

B

1

B2

BA

BB

CD

T

ol.

EE

B

Ty

pe

EC

EK

FG

GD

HH

AH

DK

LL

DO

DN

Be

ari

ng

s

Ty

pe

AC

AD

D To

l.E

EB

EC

EK

FG

GD

L

M2B

AF

355S

ML

2P 4-8P

740

610

75m

614

0M

2040

115

2067

.512

1505

Ty

pe

LA

LB

LD

MN

PS

TO

Be

ari

ng

s

DN

M2B

AF

355S

ML

2P 4-8P

2513

6574

068

080

024

613

0

395

6319

C3

6319

C3

M2B

A35

5MLC

2

M2B

A35

5MLB

4

M2B

A35

5MLC

2

M2B

A35

5MLB

446

563

22 C

363

19 C

3

100

m6

210

M24

4817

028

9016

1575

1650

1575

Page 35: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

The 'M2000' Series

M2000 Motors have been engineered for the twin objective of high power 0to weight ratio and efficiency at a designed ambient of 50 C. The

performance of 'M2BA' is well ahead of relevant IEC & IS standards resulting in lower energy consumption, reduced operational costs and ultimately faster returns on investment. 'M2BA' Motors have a wide range of applications including windmill.

Heavy duty design

The electrical and mechanical design of 'M2BA' Motors offer high performance values in all the mounting arrangements, protection class and in all applications. 'M2BA' Motors have withstood the test of time and are established for reliability in stringent operating conditions like thermal power plants world wide.

Installation Flexibility

A dual mounting hole is provided for installation flexibility i.e. same housing length can be used for varied mounting applications.

IP55

'M2BA' Motors are protected against the ingress of water and dust. A high degree of protection IP 55 is a standard feature of 'M2BA' Motors. Higher degrees of protection (e.g. IP 56) can also be made available on request.

Insulation scheme

'M2BA' Motors employ a unique polyamide based Class F insulation 0scheme rated for 155 C with temperature rise limited to Class B. The

advanced insulation the 'M2000' series gives high electrical and mechanical stability. This provides a generous thermal overload margin bringing greater reliability and improves life of the motor. This can be used for such conditions as increased load, high ambient temperature and variations in voltage and frequency.

User friendly design

'M2BA' Motors have a user friendly design and less number of components leading to faster and trouble-free dismantling and assembly.

Enclosure

'M2BA' Motors use rigid cast iron / fabricated housings and are provided with integrated deeper longitudinal ribs designed to give maximum cooling surface area. Integral feet ensure that the frame is rigid and vibration resistants. These frames are treated for high corrosion resistance. Effective and robust corrosion protection means that the motor can be used in all environments.

Winding

Stator winding uses high quality enamelled wires conforming to IS:13730. The windings are reinforced in the slots with slot wedges and on the overhang with fibre glass tape. To ensure long life, the stator is impregnated with a solventless resin. Gaps between individual conductors are effectively filled with this material resulting in good thermal conductivity and superior mechanical strength. All windings are tropicalised with epoxy gelcoat and made Insensitive to moisture and micro-organisms.

Ventilation

Ventilation circuit of 'M2BA' has been optimally designed based on aerodynamic and acoustic considerations. Special design of fan blades and segmental groupings of fins in horizontal and vertical planes offer the most efficient air flow and minimum air borne noise while incurring least windage losses.

Low noise levels

'M2BA' Motors are the result of special efforts made to minimize electromagnetic, airborne and structural noise. These motors are designed for quieter operation even under abnormal load conditions.

Terminal box

The spacious terminal box makes the motor quick and easy to connect. The terminal box can be rotated so that cables can be connected from the right or the left. Further, positioning of the terminal box assembly on the side or the top can also be made available on request. Flexible orientation of the terminal box with liberal sizing for easy access are design inbuilt.

Bearings

'M2BA' Motors use appropriately selected ball bearings with high temperature grease to give increased life and reliability. For high radial loads and belt driven applications roller bearings are provided. 'M2BA' Motors are provided with regreasing facility.

Voltage ranges for extra versatility

The motors are matched to the standard voltages applicable in India i.e.415V. However, motors for voltages ranging from 220V to 660V can also be provided on request.

Frequency converter drive

'M2BA' Motors are backed by the world class technology to incorporate inherent features in the design to take care of harmonics in frequency converter and yet offer the best performance. Special attention is given to mechanical features of 'M2BA' for reliable operation at extremes of speed range in variable speed applications.

EFFICIENCY

oC mpetitors

100

95

90

85

80

90 110 132 160 200 250 315kW

η%Typical efficiencyof 4-pole motors.

ABB

NOISE LEVEL

Competitor

s

dB (A)

Distance for measurement 1m.Standard IS : 325

ABB

Comparisons 4-pole machine IEC96

94

92

90

88

86

84

80

90 110 132 160 200 250 315kW

INSULATION CLASS

Our M-2000 Motorshave insulation class and temperature rise

FB

Limit temp.

Temprise

Ambient temp.

Overloadmargin

F155°C

B130°CE

120°C5

10

15

65

50 50

7090

50

Page 36: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

South

Khanija Bhawan, 5th Floor, West Wing, 49, Race Course RoadBangalore - 560 001Tel: +91 80 22949250Fax: +91 80 22946702/03

Chennai'Janpriya Crest', I Floor 113/96 Pantheon Rd Egmore, Chennai 600008 Tel.: +91 44 28191551/28191661Fax: +91 44 28193545

CoimbatoreTel: +91 422 2305934Fax: +91 422 2300371

HyderabadTel: +91 40 27906736,29Fax: +91 40 27906648

KochiTel: +91 484 2330342Fax: +91 484 2370343

VisakhapatnamTel: +91 891 2795837Fax: +91 891 2538188

ABB LimitedPlot Nos. 5 & 6, 2nd Stage, Peenya Industrial Area, Peenya - 560058, Bangalore, Karnataka, INDIATel: +91 80 22948310Telefax : +91 80 22948302

Regional Marketing Offices :

North

14, Mathura Road,Faridabad - 121 003 Tel: +91 129 - 2275592/9627Fax: +91 129 - 2275019

ChandigarhSCO13, 14, 15, 3rd Floor, Sec. 34 A, ChandigarhTel: +91 172 4321800Fax: +91 172 2601618

JaipurTel: +91 141 2744024Fax: +91 141 2744027

LucknowTel: +91 522 2209436Fax: +91 522 2209478

LudhianaTel: +91 161 4656831Fax: +91 161 4656830

Dehradun Tel: +91 135 2760654Fax: +91 135 2760655

East

Omega Building, 17th Floor, Bengal Intelligent Park, Block EP & GP, Sector V, Salt Lake City, Kolkata 700 091Tel: +91 33 66213000 - 11Fax: +91 33 66213187

Raipur4th & 5th Floor, Maruti Heights Aamanaka, G.E. Road, Raipur - 492 099 Tel: +91 771 4213200Fax: +91 771 4213222

BhubaneshwarTel: +91 674 6616300 -11Fax: +91 674 6616307

JamshedpurTel: +91 657 6619204Fax: +91 657 6619200

GuwhatiTel: +91 361 2464260Mob: +91 9435731532

West

ABB HouseDr. S B PathBallard Estate, Mumbai 400 038Tel: +91 22 66159888Fax: +91 22 66314203

BhopalFF - 9A, Mansarovar,Commercial Complex Hosangabad Road, Bhopal 462016Tel: +91 755 4223572Fax: +91 755 4253323

PuneTel: +91 20 66243838Fax: +91 20 66016255

VadodaraTel: +91 265 2642141-42Fax: +91 265 2638911

AhemadabadTel: +91 79 66090111

NagpurTel: +91 712 6461145,46, 48, 49Fax: +91 712 2290283

IndoreTel: +91 9981123166

www.abb.co.in

CA

T-

03

R-1

27.

02.2

010

Page 37: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

eSt el

Power

ee

t

Cm

n

Paper

mn

Cee

t

pr

Pae

M2BA & HX+

The most widely used motors from the world leaders

Page 38: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

TEFC, S1 Duty415 ± 10% V, 50Hz ± 5%.Combined Variation (absolute sum 10%)

Insulation Class F0Ambient temp 50 C

0Temperature rise Class B ( 70 C)

I = Nominal or rated currentn

T = Nominal or rated torque in Nm T = Cold withstand time T = Hot withstand time n cold hot

Note : All performance figures are subject to IS tolerances.

T = Maximum torque I = Starting current T = Starting torquemax s s

2 Pole Ambient 50°C

4 Pole Ambient 50°C

6 Pole Ambient 50°C

8 Pole Ambient 50°C

0.37

0.55

0.75

1.1

1.5

2.2

3.7

5.5

7.5

9.3

0.84

0.82

0.82

0.81

0.82

0.89

0.91

0.80

0.87

0.92

1.29

1.90

2.52

3.70

4.95

7.30

12.4

18.2

24.8

31.3

2.2

2.7

2.6

2.9

2.7

2.7

2.2

2.6

2.2

2.8

3.2

2.8

3.4

3.0

3.3

3.0

2.6

3.6

3.3

3.4

11

11

14

16

22

25

36

61

70

80

0.00039

0.00051

0.00080

0.00101

0.00199

0.00280

0.00528

0.01029

0.01359

0.01951

58

58

60

60

63

68

68

75

75

75

72.7

77.2

77.0

82.8

82.3

85.6

84.7

86.8

90.0

87.7

72.0

78.4

77.8

82.9

82.4

86.5

86.3

87.4

90.4

88.2

0.90

1.20

1.60

2.40

3.20

4.10

6.70

11.0

13.5

16.2

4.0

4.7

3.7

5.7

6.0

6.5

6.2

6.5

6.5

6.5

M2BA71A2

M2BA71B2

M2BA80A2

M2BA80B2

M2BA90S2

M2BA90LB2

M2BA100LB2

M2BA132SA2

M2BA132SBB2

M2BA132SC2

2790

2760

2840

2825

2890

2875

2855

2890

2880

2840

3GBA 071 001-••B

3GBA 071 002-••B

3GBA 081 001-••B

3GBA 081 002-••B

3GBA 091 001-••B

3GBA 091 003-••B

3GBA 101 002-••B

3GBA 131 001-••B

3GBA 131 004-••B

3GBA 131 003-••B

Outputkw

ProductCodeMotor Type Speed

r/min

Efficiency,IEC 60034-2

1996

FL 3/4FL

Power Factor

cos100%

Current

In

(A)Is

In

Torque

Tn

(Nm)Ts

Tn

Tmax

Tn

Moment ofinertia

2J=1/4 Gd2kgm

Weightfoot

mountedkg

Soundpressure

leveldB(A)

Outputkw

ProductCodeMotor Type Speed

r/min

Efficiency,IEC 60034-2

1996

FL 3/4FL

Power Factor

cos100%

Current

In

(A)Is

In

Torque

Tn

(Nm)Ts

Tn

Tmax

Tn

Moment ofinertia

2J=1/4 Gd2kgm

Weightfoot

mountedkg

Soundpressure

leveldB(A)

0.09

0.12

0.18

0.25

0.37

0.55

0.75

1.1

1.5

2.2

43.8

44.4

57.8

64.0

64.8

67.0

71.3

73.5

74.6

81.2

35.5

36.1

52.4

62.1

62.4

64.4

68.5

73.1

76.0

81.0

0.53

0.53

0.57

0.64

0.56

0.59

0.60

0.63

0.71

0.60

0.55

0.70

0.77

0.88

1.40

2.0

2.5

3.25

3.9

6.0

2.3

2.3

3.0

3.1

2.9

2.6

3.9

3.6

3.5

4.0

1.25

1.67

2.45

3.5

5.0

7.6

10.0

15.1

20.9

29.3

2.1

2.2

2.4

2.1

1.6

1.5

2.4

2.1

1.9

1.9

2.5

2.4

2.6

2.4

2.3

2.0

2.7

2.7

2.2

2.6

11

12

15

17

24

25

30

34

28

70

0.00089

0.0011

0.00187

0.00239

0.00444

0.00491

0.0072

0.00871

0.0118

0.03336

40

40

45

45

43

43

46

46

42

56

M2BA71A8

M2BA71B8

M2BA80A8

M2BA80B8

M2BA90L8

M2BA90LB8

M2BA100LA8

M2BA100LB8

M2BA112MA8

M2BA132S8

3GBA 074 001-••B

3GBA 074 002-••B

3GBA 084 001-••B

3GBA 084 002-••B

3GBA 094 002-••B

3GBA 094 003-••B

3GBA 104 001-••B

3GBA 114 002-••B

3GBA 114 001-••B

3GBA 134 001-••B

700

700

705

695

705

690

710

705

685

720

0.18

0.25

0.37

0.55

0.75

1.1

1.5

2.2

3.7

5.5

59.8

63.5

69.8

72.4

75.1

77.3

81.5

82.4

85.7

87.8

56.4

61.5

69.7

74.0

74.7

77.8

81.3

83.3

84.8

87.4

0.70

0.71

0.71

0.70

0.64

0.69

0.68

0.72

0.68

0.70

0.6

0.8

1.1

1.5

2.2

2.9

3.8

5.2

8.8

12.5

3.3

3.4

3.0

3.8

4.4

4.1

4.4

4.4

5.2

5.0

1.9

2.7

3.8

5.7

7.6

11.3

15.0

22.2

36.4

54.0

2.2

2.2

2.3

2.1

2.3

2.3

2.2

2.2

2.1

1.8

2.3

2.6

2.8

2.7

3.4

2.6

2.7

2.4

2.5

2.7

10

12

15

17

25

25

37

40

69

86

0.00089

0.0011

0.00187

0.00239

0.00444

0.00491

0.00873

0.0114

0.03336

0.0487

42

42

47

47

44

44

49

54

57

57

M2BA71A6

M2BA71B6

M2BA80A6

M2BA80B6

M2BA90L6

M2BA90LB6

M2BA100L6

M2BA112M6

M2BA132MA6

M2BA132MC6

3GBA 073 001-••B

3GBA 073 002-••B

3GBA 083 001-••B

3GBA 083 002-••B

3GBA 093 002-••B

3GBA 093 003-••B

3GBA 103 002-••B

3GBA 113 001-••B

3GBA 133 002-••B

3GBA 133 004-••B

905

885

920

925

940

925

955

945

970

970

Outputkw

ProductCodeMotor Rype Speed

r/min

Efficiency,IEC 60034-2

1996

FL 3/4FL

Power Factor

cos100%

Current

In

(A)Is

In

Torque

Tn

(Nm)Ts

Tn

Tmax

Tn

Moment ofinertia

2J=1/4 Gd2kgm

Weightfoot

mountedkg

Soundpressure

leveldB(A)

3GBA 072 001-••B

3GBA 072 002-••B

3GBA 082 001-••B

3GBA 082 002-••B

3GBA 092 001-••B

3GBA 092 002-••B

3GBA 102 001-••B

3GBA 112 001-••B

3GBA 132 001-••B

3GBA 132 002-••B

10

11

15

16

22

25

34

39

60

70

0.00074

0.00088

0.00144

0.00198

0.0033

0.00444

0.00873

0.0106

0.02635

0.03282

45

45

50

50

50

50

64

60

66

66

0.25

0.37

0.55

0.75

1.1

1.5

2.2

3.7

5.5

7.5

66.5

69.6

71.8

75.5

76.8

79.6

82.8

85.0

88.3

88.4

65.5

71.2

72.2

76.0

77.1

80.1

83.3

86.2

88.4

88.9

0.76

0.79

0.80

0.74

0.78

0.80

0.83

0.83

0.78

0.80

0.75

0.90

1.36

1.90

2.60

3.40

4.60

7.50

11.1

14.8

3.8

4.5

4.3

5.1

5.3

5.5

5.6

5.9

5.5

6.0

1.70

2.53

3.80

5.10

7.40

10.1

14.7

24.8

36.1

49.4

2.2

2.0

2.2

2.2

2.6

2.7

2.2

2.6

2.1

2.1

2.4

2.5

2.8

3.1

3.0

3.4

2.7

3.0

2.5

2.7

M2BA71A4

M2BA71B4

M2BA80A4

M2BA80B4

M2BA90S4

M2BA90L4

M2BA100LA4

M2BA112M4

M2BA132S4

M2BA132M4

1390

1400

1390

1405

1410

1420

1430

1425

1455

1450

Outputkw

ProductCodeMotor Type Speed

r/min

Efficiency,IEC 60034-2

1996

FL 3/4FL

Power Factor

cos100%

Current

In

(A)Is

In

Torque

Tn

(Nm)Ts

Tn

Tmax

Tn

Moment ofinertia

2J=1/4 Gd2kgm

Weightfoot

mountedkg

Soundpressure

leveldB(A)

Page 39: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

Fla

nge-

mou

nted

mot

or, l

arge

flan

ge;

IM B

5 (I

M 3

001)

, IM

300

2

M2B

A 7

1...1

32 (

Flan

ge M

ount

ed)

M2B

A 7

1...1

32 (

Foot

Mou

nted

)

Fla

nge-

mou

nted

mot

or, s

mal

l fla

nge;

IM B

14 (I

M 3

601)

71 80 90S

90L

100

112

132S

132M

112

125

140

140

160

190

216

216

24 28 30 30 38 41 47 47

136

154

170

170

200

230

262

262

139

157

177

177

197

197

261

261

97 97 110

110

110

110

160

160

Mot

orS

ize

AA

AA

BA

CA

E

71 80 90 100

112

132

5 6 8 8 8 10

4 5 5 6 6 8

11 15.5

20 24 24 33

16 21.5

27 31 31 41

8.5

11 11 15.5

15.5

20

Mot

orS

ize

FFA

GG

AG

B

IM B

3 (I

M 1

001)

, IM

100

2

71 80 90 100

112

132

105

113

127

145

145

166

9 10 10 11 11 12.5

130

165

165

215

215

265

110

130

130

180

180

230

160

200

200

250

250

300

10 12 12 15 15 15

3.5

3.5

3.5

4.0

4.0

4.0

Mot

orS

ize

HB

LAM

NP

ST

IM B

5 (I

M 3

001)

, IM

300

2

IM B

14 (I

M 3

601)

, IM

360

2

139

157

177

177

197

197

261

261

104

111

156.

513

1.5

123

138

228

190

90 100

100

125

140

140

140

178

10 12.5

12.5

12.5

16 16 16 16

24 28 30 30 34 34 40 40

14-j6

19-j6

24-j6

24-j6

28-j6

28-j6

38-k

638

-k6

110

125

150

150

172

172

212

212

11 14 14 14 19 19 24 24

24 28 55 55 34 34 76 76

M5

M6

M8

M8

M10

M10

M12

M12

45 50 56 56 63 70 89 89

M4

M5

M5

M5

M6

M6

M8

M8

30 40 50 50 60 60 80 80

23 30 30 30 40 40 50 50

12.5

16 19 19 22 22 28 28

10 12.5

12.5

12.5

16 16 19 19

AF

BB

AB

BB

CC

CA

CB

D-T

ol.

DA

DB

DC

EE

AE

GE

H

12.5

16 16 21.5

21.5

27

7 10 10 12 12 12

71 80 90 100

112

132

264

296

357

381

403

533

9 10 11 12 12 14

292

331

392.

542

644

858

7

151

168

189

217

229

272

M16

x1.5

M25

x1.5

M25

x1.5

M32

x1.5

M32

x1.5

M32

x1.5

176

193

217

245

257

298

M16

x1.5

M25

x1.5

M25

x1.5

M32

x1.5

M32

x1.5

M32

x1.5

62 69 79 94 94 116

34 37 46 49 49 71

97 97 110

110

110

160

27.5

27.5

35 32 32 77

69.5

69.5

77 80 80 125

GC

HH

AH

CH

DH

EK

LLC

UB

UC

VA

VB

VC

VD

71 80 90 100

112

132

105

113

127

145

145

166

8 8 10 10 10 12

85 100

115

130

130

165

70 80 95 110

110

130

105

120

140

160

160

200

M6

M6

M8

M8

M8

M10

2.5

3.0

3.0

3.5

3.5

3.5

Mot

orS

ize

HB

LAM

NP

ST

All

dim

ensi

on a

re in

mm

.

Tol

eran

ces:

A,B

+ -

0.8

H+

0 -0

.5D

, DA

ISO

j6N

ISO

j6F

, FA

ISO

h9

C, C

A+

-0.8

Foo

t-m

ount

ed m

otor

;IM

B3

(IM

100

1), I

M 1

002

Page 40: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

RatedSpeed (rpm)

WeightKg

In

(A) (Sec)Thot

2 GD2 KgmNm

TnI /Is n (Sec)TcoldFrame Size

Efficiency %

FL 3/4FL 1/2FL

Power Factor

FL 3/4FL 1/2FL

Torque

T /Ts n T /Tmax n

Outputkw hp

RatedSpeed (rpm)

WeightKg

In

(A) (Sec)Thot

2 GD2 KgmNm

TnI /Is n (Sec)TcoldFrame Size

Efficiency %

FL 3/4FL 1/2FL

Power Factor

FL 3/4FL 1/2FL

Torque

T /Ts n T /Tmax n

Outputkw hp

RatedSpeed (rpm)

WeightKg

In

(A) (Sec)Thot

2 GD2 KgmNm

TnI /Is n (Sec)TcoldFrame Size

Efficiency %

FL 3/4FL 1/2FL

Power Factor

FL 3/4FL 1/2FL

Torque

T /Ts n T /Tmax n

Outputkw hp

TEFC, S1 Duty415 ± 10% V, 50Hz ± 5%.Combined Variation (absolute sum 10%)

Insulation Class F0Ambient temp 50 C

0Temperature rise Class B ( 70 C)

I = Nominal or rated current I = Starting currentn s

T = Nominal or rated torque in Nm T = Starting torquen s

T = Maximum torque T = Hot withstand timemax hot

T = Cold withstand timecold

Note : All performance figures are subject to IS tolerances.

2 Pole Ambient 50°C

4 Pole Ambient 50°C

6 Pole Ambient 50°C

8 Pole Ambient 50°C

20.0

26.0

32.0

37.5

51.0

62.0

75.0

91.5

123.0

147.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

36.2

49.4

60.9

72

97

120

145

177

242

290

120

130

145

170

240

260

330

440

610

640

12

12

12

20

20

20

20

20

20

20

28

28

28

46

46

46

46

46

46

46

0.128

0.152

1.82

0.25

0.72

0.78

1.28

1.92

3.28

3.42

2900

2900

2900

2925

2940

2940

2955

2960

2965

2965

2.2

2.2

2.5

2.3

2.3

2.4

2.6

2.4

2.0

2.2

2.8

3.0

2.9

3.0

3.0

2.7

3.0

3.0

3.0

3.0

0.87

0.87

0.90

0.89

0.88

0.89

0.89

0.89

0.90

0.90

0.85

0.85

0.87

0.87

0.86

0.87

0.87

0.87

0.88

0.89

0.82

0.82

0.84

0.81

0.81

0.81

0.81

0.81

0.82

0.83

88.0

89.0

91.0

92.1

92.6

93.1

93.5

94.0

94.2

94.5

88.0

89.0

91.0

92.1

92.6

93.1

93.5

94.0

94.2

94.5

87.0

88.0

90.0

91.1

91.0

92.1

92.5

93.0

93.2

93.5

HX+160MLB2

HX+160MLD2

HX+160MLE2

HX+180MLB2

HX+200MLB2

HX+200MLC2

HX+225SMC2

HX+250MB2

HX+280SMB2

HX+280SMC2

11

15

18.5

22

30

37

45

55

75

90

15

20

25

30

40

50

60

75

100

125

18.8

21.0

28.0

34.5

40.5

54.5

67.0

81.0

98.5

131.0

157.0

88.0

89.0

89.0

90.6

91.5

92.6

92.8

93.3

93.8

93.8

94.0

88.0

89.0

89.0

90.6

91.5

92.6

92.8

93.3

93.8

93.8

94.0

86.0

87.0

87.0

89.6

90.5

91.6

91.8

92.3

92.8

92.8

93.0

0.81

0.82

0.82

0.82

0.83

0.83

0.83

0.83

0.83

0.85

0.85

0.74

0.76

0.76

0.76

0.78

0.78

0.78

0.78

0.78

0.81

0.82

0.63

0.66

0.66

0.66

0.70

0.70

0.70

0.70

0.70

0.72

0.73

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

2.2

2.1

2.1

2.4

2.6

2.6

2.2

2.2

2.4

2.3

2.4

2.8

2.8

2.8

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

61

72.2

98.8

121

144

195

240

292

356

486

583

125

145

150

175

185

245

310

340

435

610

680

8

12

14

15

15

15

20

20

20

20

20

18

28

30

34

34

34

46

46

46

46

46

0.028

0.252

0.272

0.48

0.54

1.20

1.40

1.52

2.80

4.44

5.32

1455

1455

1450

1455

1460

1470

1470

1470

1475

1475

1475

9.3

11

15

18.5

22

30

37

45

55

75

90

12.5

15

20

25

30

40

50

60

75

100

125

HX+160MLB4

HX+160MLD4

HX+160MLE4

HX+180MLB4

HX+180MLC4

HX+200MLC4

HX+225SMB4

HX+225SMC4

HX+250MB4

HX+280SMB4

HX+280SMC4

7.5

9.3

11

15

18.5

22

30

37

45

55

10

12.5

15

20

25

30

40

50

60

75

15.5

19.0

23.0

30.0

36.0

42.0

55.5

66.0

79.5

97.0

87.5

88.0

88.0

89.0

90.5

91.7

92.1

92.8

93.6

93.8

87.5

88.0

88.0

89.0

90.5

91.7

92.1

92.8

93.6

93.8

86.5

86.0

86.0

87.0

88.5

89.7

90.1

90.8

91.6

91.8

0.77

0.77

0.77

0.79

0.79

0.79

0.82

0.84

0.84

0.84

0.72

0.72

0.72

0.72

0.72

0.72

0.76

0.80

0.80

0.80

0.60

0.60

0.60

0.59

0.59

0.59

0.66

0.71

0.71

0.71

5.5

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

1.9

2.0

2.0

2.4

2.3

2.4

2.4

2.4

2.3

2.1

2.5

2.5

2.5

3.0

3.0

3.0

2.8

2.8

2.6

2.7

74.6

92

109

148

179

213

291

359

436

533

145

155

170

185

230

300

320

420

590

600

8

8

9

15

15

15

20

20

20

20

18

18

20

34

34

34

46

46

46

46

0.326

0.372

0.446

0.68

1.60

1.80

2.98

4.80

7.20

8.10

960

965

965

965

985

985

985

985

985

985

HX+160MLC6

HX+160MLD6

HX+160MLE6

HX+180MLC6

HX+200MLB6

HX+200MLC6

HX+225SMC6

HX+250MB6

HX+280SMB6

HX+280SMC6

3.7

5.5

7.5

9.3

11

15

18.5

22

30

37

45

5.0

7.5

10.0

12.5

15.0

20.0

25.0

30.0

40.0

50.0

60.0

8.0

12.0

16.0

20.0

23.5

31.5

38.5

45.5

60.0

73.5

89.0

82.5

84.5

85.0

87.0

87.0

88.0

90.0

91.0

91.5

92.0

92.5

82.5

83.5

84.0

87.0

87.0

88.0

90.0

91.0

91.5

92.0

92.5

79.5

81.5

82.0

85.0

85.0

86.0

89.0

89.0

89.5

90.0

90.5

0.77

0.79

0.79

0.75

0.75

0.75

0.74

0.74

0.76

0.76

0.76

0.70

0.72

0.72

0.67

0.67

0.67

0.66

0.66

0.68

0.73

0.73

0.61

0.59

0.59

0.53

0.53

0.53

0.52

0.52

0.54

0.61

0.61

5.1

5.1

5.1

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

1.8

1.8

1.8

1.8

2.0

2.2

2.2

2.1

2.1

2.1

2.1

2.4

2.5

2.5

2.6

2.5

2.5

2.3

2.3

2.3

2.3

2.3

49.4

73.5

98.8

123

145

195

240

286

387

478

581

125

155

170

160

170

240

320

340

520

590

600

9

13

15

13

13

15

18

18

18

18

18

20

29

30

29

29

34

40

40

40

40

40

0.288

0.372

0.446

0.64

0.72

1.98

3.32

3.50

4.54

7.64

7.75

715

715

715

725

725

735

735

735

740

740

740

HX+160MLB8

HX+160MLD8

HX+160MLE8

HX+180MLA8

HX+180MLB8

HX+200MLC8

HX+225SMB8

HX+225SMC8

HX+250MB8

HX+280SMB8

HX+280SMC8

RatedSpeed (rpm)

WeightKg

In

(A) (Sec)Thot

2 GD2 KgmNm

TnI /Is n (Sec)TcoldFrame Size

Efficiency %

FL 3/4FL 1/2FL

Power Factor

FL 3/4FL 1/2FL

Torque

T /Ts n T /Tmax n

Outputkw hp

Page 41: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

2P 4-8P

HX

+225

SM

2P 4-8P

HX

+16

0ML

HX

+18

0ML

HX

+25

0M

HX

+28

0SM

2P 4-8P

HX

+20

0ML

90 115

1853 58

20

1211

250

280

40

HX

+ 16

0...2

80 (

Foot

Mou

nted

)M

ount

ing

Des

igna

tion

B3,

B6,

B7,

B8,

V5,

V6

HX

F+ 1

60...

280

(Fla

nge

Mou

nted

)M

ount

ing

Des

igna

tion

B5,

V1

ØS

ØN

—j6

ØM

±0.

3

ØP

22.5

°2

25

GD

F —

h9

G

ØD

2 N

os. M

10 E

arth

ing

Scr

ew

EB

EC

L

EK E

LA

LB

ØAC

T

G

F –

h9

GD

ØD

ØA

C

HD

H

HA

A

AA

AB

ØK

B’

B BB

2 N

os

. M

10

Ea

rth

ing

Sc

rew

0-0.5

65–m

6

75–m

6

110

M2

014

0

55–m

6

42

* F

or H

X+

200

MLC

2, L

= 7

70m

m*

For

160

–250

fram

e: s

heet

met

al te

rmin

al b

ox, 2

80 fr

ame:

cas

t iro

n te

rmin

al b

ox*

For

160

–200

fram

e fla

nge

mou

nted

mot

ors,

4 n

os m

ount

ing

hole

s ar

e pr

ovid

ed*

For

225

–280

fram

e fla

nge

mou

nted

mot

ors,

8 n

os m

ount

ing

hole

s ar

e pr

ovid

edAD

BA C

E

L

EK

EC

EB

2P 4-8P

HX

+22

5SM

2P 4-8P

HX

+16

0ML

HX

+18

0ML

HX

+25

0M

HX

+28

0SM

2P 4-8P

HX

+20

0ML

M16

36

67

.5

Type

AA

AA

BA

CB

B'

BA

BB

CD

–To

l.E

EB

EC

254

279

318

60 58 70

310

324

378

305

348

381

210

241

267

65 58 81

310

324

354

108

121

133

254

279

305

356

6541

644

228

683

360

149

311

406

8047

349

534

993

406

168

-

457

8553

055

636

810

548

619

041

9

42–k

648

–k6

60–m

6

Bea

ring

DS

ND

SL

KH

DH

AH

GD

GF

EK

Type

12 14 16 16

37 42.5

49 49

8 9 10 10

160

180

200

225

22 26 30 32

612

910

728

1040

407

446

484

562

2415 15 19

671

706

731

1983

3

6309

ZZ

C3

6310

ZZ

C3

6312

ZZ

C3

6308

ZZ

C3

6309

ZZ

C3

6311

ZZ

C3

6315

C3

6313

C3

6316

C3

6315

C3

6313

C3

6312

C3

HX

F+

160M

LH

XF

+18

0ML

2P 4-8P

HX

F+

225S

M

2P 4-8P

HX

F+

280S

M

HX

F+

250M

2P 4-8P

HX

F+

200M

L

Type

AC

AD

305

348

381

247

266

284

442

337

495

362

556

448

D –

Tol.

42–k

648

–k6

55–m

6

60–m

6

75–m

6

65–m

6

E 110

140

EB

M16

M20

EC 36 42

EK 90 115

F 12 14 16 2018

G 37 42.5

49 67.553 58

GD 8 9 10 1211

L 671

706

731

833

910

1040

HX

F+

160M

L

HX

F+

180M

L

2P 4-8P

HX

F+

225S

M

2P 4-8P

HX

F+

280S

M

HX

F+

250M

2P 4-8P

HX

F+

200M

L

Type

LALB

1656

1

596

621

723

693

22

M 300

350

400

500

PS 19

T 5

20

770

900

300

N–T

ol.

250–

j635

0

300–

j640

0

350–

j645

0

450–

j655

0

250–

j635

0

Bea

ring

DS

ND

S63

09Z

Z C

3

6310

ZZ

C3

6312

ZZ

C3

6308

ZZ

C3

6309

ZZ

C3

6311

ZZ

C3

6315

C3

6313

C3

6316

C3

6315

C3

6313

C3

6312

C3

Page 42: Catalog Low voltage General performance IE2 high ef ciency motors · 2017. 9. 7. · IE2 IP 55 - IC 411 - Insulation class F, temperature rise class B IE2 efficiency class according

South

Khanija Bhawan, 5th Floor, West Wing, 49, Race Course RoadBangalore - 560 001Tel: +91 80 22949250Fax: +91 80 22946702/03

Chennai'Janpriya Crest', I Floor 113/96 Pantheon Rd Egmore, Chennai 600008 Tel.: +91 44 28191551/28191661Fax: +91 44 28193545

CoimbatoreTel: +91 422 2305934Fax: +91 422 2300371

HyderabadTel: +91 40 27906736,29Fax: +91 40 27906648

KochiTel: +91 484 2330342Fax: +91 484 2370343

VisakhapatnamTel: +91 891 2795837Fax: +91 891 2538188

ABB Limited32, Industrial Area, N.I.T., Faridabad - 121 001 Tel: +91 129 2448100Fax : +91 129 4023006

Regional Marketing Offices :

North

14, Mathura Road,Faridabad - 121 003 Tel: +91 129 - 2275592/9627Fax: +91 129 - 2275019

ChandigarhSCO13, 14, 15, 3rd Floor, Sec. 34 A, ChandigarhTel: +91 172 4321800Fax: +91 172 2601618

JaipurTel: +91 141 2744024Fax: +91 141 2744027

LucknowTel: +91 522 2209436Fax: +91 522 2209478

LudhianaTel: +91 161 4656831Fax: +91 161 4656830

Dehradun Tel: +91 135 2760654Fax: +91 135 2760655

East

Omega Building, 17th Floor, Bengal Intelligent Park, Block EP & GP, Sector V, Salt Lake City, Kolkata 700 091Tel: +91 33 66213000 - 11Fax: +91 33 66213187

Raipur4th & 5th Floor, Maruti Heights Aamanaka, G.E. Road, Raipur - 492 099 Tel: +91 771 4213200Fax: +91 771 4213222

BhubaneshwarTel: +91 674 6616300 -11Fax: +91 674 6616307

JamshedpurTel: +91 657 6619204Fax: +91 657 6619200

GuwhatiTel: +91 361 2464260Mob: +91 9435731532

West

ABB HouseDr. S B PathBallard Estate, Mumbai 400 038Tel: +91 22 66159888Fax: +91 22 66314203

BhopalFF - 9A, Mansarovar,Commercial Complex Hosangabad Road, Bhopal 462016Tel: +91 755 4223572Fax: +91 755 4253323

PuneTel: +91 20 66243838Fax: +91 20 66016255

VadodaraTel: +91 265 2642141-42Fax: +91 265 2638911

AhemadabadTel: +91 79 66090111

NagpurTel: +91 712 6461145,46, 48, 49Fax: +91 712 2290283

IndoreTel: +91 9981123166

www.abb.co.in

CA

T-

02

R-1

27.

02.2

010