3
Power Distribution and Protection > Circuit Breakers > Miniature Circuit Breakers and Earth Leakage Protection (RCDs and RCBOs) > DIN-Safe Residual Current Device > DIN-Safe RCCB Add-on Module (DSRCM) > 3P+N DSRCM RCD DIN-SAFE CLIP ON 3P+N 32A 30mA TYPE AC DSRCM32-30-3PN Catalogue No: · Complies with AS3190 (RCCBs) · DIN-SAFE Add-on-Modules feature 10kA conditional short circuit rating · 1P+N, 3P and 3P+N for single or three phase loads · Type AC RCD · 30mA, 100mA, 300mA RCD options · Suits pole-covers, loadcentres and the Concept range of Panelboards · Approval No N11974 or RCM Representative Photo Only (actual product may vary based on configuration selections) RCD CLIP ON 32A 30MA 3PN SPECIFICATIONS Component Type Power Distribution & Protection RCD Type, AS/NZS 61008/61009 Tripping Time at IΔn, Instantaneous In, Rated Current at 30°C IΔn, Rated Leakage Current Poles Number of Poles versus Modules Rated Frequency Un, Nominal Operational Voltage, AC Ubmin, Service Voltage, AC, Min Ubmax, Service Voltage, AC, Max Uimp, Impulse Withstand Voltage, 1.2/50µs Grid Distance (Safety Difference Between 2 Devices) Ui, Rated Insulation Voltage Insulation Resistance Dielectric Strength Electrical Service Life at Un, In Mechanical Service Life IP Rating, Inside IP Rating, Outside Flammability Rating (UL94) Wire / Conductor Size, Rigid Cable, Top, Max Wire / Conductor Size, Flex Cable, Top, Max Wire / Conductor Size, Rigid Cable, Out, Min Wire / Conductor Size, Flex Cable, Out, Min Tightening Torque, Bottom, Nominal Trip-Free Mechanism Mounting RCD AC <40 ms 32 A @30°C 30 mA 3P + N 2 50 / 60 Hz 415 V AC 287 V AC 455 V AC 6 kV, 1.2/50µs 35 mm 500 V (rms) 1000 MΩ 2500V V AC 10000 cycles 20000 cycles IP40 IP20 UL 94 V-2 16 mm² Top 16 mm² Top 1 mm² Out 1 mm² Out 4.5 Nm Yes DIN-35 Rail Mount Page 1 of 3 4 November 2021, 1300 NHP NHP | nhp.com.au | 0800 NHP NHP | nhp-nz.com DSRCM32303PN Datasheet NHP Electrical Engineering Products

Catalogue No: DSRCM32-30-3PN RCD DIN-SAFE CLIP ON …

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Power Distribution and Protection > Circuit Breakers > Miniature Circuit Breakers and Earth Leakage Protection (RCDsand RCBOs) > DIN-Safe Residual Current Device > DIN-Safe RCCB Add-on Module (DSRCM) > 3P+N DSRCM

RCD DIN-SAFE CLIP ON 3P+N 32A 30mA TYPE AC

DSRCM32-30-3PNCatalogue No:

· Complies with AS3190 (RCCBs)· DIN-SAFE Add-on-Modules feature 10kA conditional

short circuit rating· 1P+N, 3P and 3P+N for single or three phase loads· Type AC RCD· 30mA, 100mA, 300mA RCD options· Suits pole-covers, loadcentres and the Concept range

of Panelboards· Approval No N11974 or RCM

Representative Photo Only(actual product may vary based on configuration selections)

RCD CLIP ON 32A 30MA 3PN

SPECIFICATIONS

Component Type Power Distribution & Protection

RCD Type, AS/NZS 61008/61009

Tripping Time at IΔn, Instantaneous

In, Rated Current at 30°C

IΔn, Rated Leakage Current

Poles

Number of Poles versus Modules

Rated Frequency

Un, Nominal Operational Voltage, AC

Ubmin, Service Voltage, AC, Min

Ubmax, Service Voltage, AC, Max

Uimp, Impulse Withstand Voltage, 1.2/50µs

Grid Distance (Safety Difference Between 2 Devices)

Ui, Rated Insulation Voltage

Insulation Resistance

Dielectric Strength

Electrical Service Life at Un, In

Mechanical Service Life

IP Rating, Inside

IP Rating, Outside

Flammability Rating (UL94)

Wire / Conductor Size, Rigid Cable, Top, Max

Wire / Conductor Size, Flex Cable, Top, Max

Wire / Conductor Size, Rigid Cable, Out, Min

Wire / Conductor Size, Flex Cable, Out, Min

Tightening Torque, Bottom, Nominal

Trip-Free Mechanism

Mounting

RCD

AC

<40 ms

32 A @30°C

30 mA

3P + N

2

50 / 60 Hz

415 V AC

287 V AC

455 V AC

6 kV, 1.2/50µs

35 mm

500 V (rms)

1000 MΩ

2500V V AC

10000 cycles

20000 cycles

IP40

IP20

UL 94 V-2

16 mm² Top

16 mm² Top

1 mm² Out

1 mm² Out

4.5 Nm

Yes

DIN-35 Rail Mount

Page 1 of 34 November 2021,1300 NHP NHP | nhp.com.au | 0800 NHP NHP | nhp-nz.com

DSRCM32303PN DatasheetNHP Electrical Engineering Products

Power Distribution and Protection > Circuit Breakers > Miniature Circuit Breakers and Earth Leakage Protection (RCDsand RCBOs) > DIN-Safe Residual Current Device > DIN-Safe RCCB Add-on Module (DSRCM) > 3P+N DSRCM

RCD DIN-SAFE CLIP ON 3P+N 32A 30mA TYPE AC

DSRCM32-30-3PNCatalogue No:

Add-On Devices (side add-on)

Padlockable

Sealable

Centre Trip Position

Height

Width

Depth

Weight

Package Quantity

Standards Compliance

Operating Temperature, Min

Operating Temperature, Max

Storage Temperature, Min

Storage Temperature, Max

Relative Humidity, Max

Shock Acceleration (Max.)

Shock Duration (Max.)

Shock Rating

Vibration Acceleration (Max.)

Vibration Frequency, Operational (Max.)

Vibration Duration (Max.)

Vibration Rating

UVTShunt TripMotor OperatorPanelboard Switch

No

No

No

86 mm

36 mm

76 mm

0.34 kg

1 qty

IEC 60077-16-3IEC 60068-2-6IEC 60947-1DIN 40046UL 94 V-2IEC 60068-2

-5 °C min

60 °C max

-25 °C min

70 °C max

95 %RH

40 g

5 ms

IEC 60077-16-3

5 m/s²

80 Hz

30 min

IEC 60068-2-6

REFERENCES

Installation Guide: -

User Manual: -

Manufacturer Datasheet: -

Manufacturer Catalogue& Product Selection:

-

Supplier Declaration ofConformity:

DSRCMxxxxxxx_Supplier Declaration of Conformity (SDoC)

IECEx Certificate -

Page 2 of 34 November 2021,1300 NHP NHP | nhp.com.au | 0800 NHP NHP | nhp-nz.com

DSRCM32303PN DatasheetNHP Electrical Engineering Products

Power Distribution and Protection > Circuit Breakers > Miniature Circuit Breakers and Earth Leakage Protection (RCDsand RCBOs) > DIN-Safe Residual Current Device > DIN-Safe RCCB Add-on Module (DSRCM) > 3P+N DSRCM

RCD DIN-SAFE CLIP ON 3P+N 32A 30mA TYPE AC

DSRCM32-30-3PNCatalogue No:

Dimension Diagram

Connection / Wiring Diagram

Page 3 of 34 November 2021,1300 NHP NHP | nhp.com.au | 0800 NHP NHP | nhp-nz.com