Upload
rosalind-gaines
View
230
Download
0
Tags:
Embed Size (px)
Citation preview
CCNA1 v3 Module 9
v3v3A+
Type 1
JEOPARDY
K. Martin
CCNA1 v3 Module 9
RouterRouterModesModes
WANWANEncapsulationEncapsulation
WANWANServicesServices
RouterRouterBasicsBasics
RouterRouterCommands Commands
100
200
300
400
500
RouterRouterModesModes
WANWANEncapsulationEncapsulation
WANWANServicesServices
RouterRouterBasicsBasics
RouterRouterCommands Commands
100 100 100 100 100
200 200 200 200 200
300 300 300 300 300
400 400 400 400 400
500 500 500 500 500
Type 1Type 1aa
Type 1b
Type 1Type 1cc
Type 1Type 1dd
Type 1e
Type 1Type 1ff
100
200
300
400
500
100
200
300
400
500
► ► ► F i n a l J e o p a r d y ◄ ◄ ◄
CCNA1 v3 Module 9
Question
The sale of CFC and HCFC refrigerants is restricted to:
Type 1 a100
A: What is EPA certified technicians?
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
CCNA1 v3 Module 9
QuestionA: What is an MVAC-like system?
Which of the following is not a type 1 appliance:
CCNA1 v3 Module 9
Type 1 a200
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500
A: What is repair the leak, but do so when possible?
When servicing a small appliance for leak repairs, it’s not mandatory to:
CCNA1 v3 Module 9
Type 1 a300
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500
A: What is small appliances?
Any person who opens an appliance for leak repair maintenance service or repair must have at least one-self-contained recovery machine available unless they are working on:
CCNA1 v3 Module 9
Type 1 a
400
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
A: What is leak tested before proceeding with recovery?
When installing any type of access fitting onto a sealed system, the fitting should be:
Type 1 a500
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
A: What is 75 psig?
A storage cylinder of recovery R-12 at normal room temp (75) in the absence of non-condensable will be pressurized for…
Type 1 b100
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
A: What is capturing refrigerant in a non-pressurized container?
The system-dependent (passive) recovery process for small appliance works by:
Type 1 b 200
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
A: What is the Phosgene gas, hydrochloric acid and hydrofluoric acid?
At high temps, R-12 and R-22 can decompose to form…
Type 1 b 300
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
A: What is Refuse to process the refrigerant, Agree to destroy refrigerant
If a reclamation facility receives a tank of mixed refrigerant, they may:
Type 1 b
400
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
A: What is it can enhance, speed of recovery and may be necessary to achieve required efficiency
When a household refrigerant compressor does not run, it is recommended that low and high access valves be installed when recovering refrigerant from system because:
Type 1 b 500
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
A: What is 130 psi?
A storage cylinder of recovery R-22 at normal room temp (75) in the absence of non-condensable will be pressured to
Type 1 c 100
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
A: What is copper and aluminum?
Its generally recommended that piercing type valves be used on these tubing methods:
Type 1 c 200
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
A: What is NONE?
Which refrigerants can be mixed?
Type 1 c300
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
A: What is 95 psi?
A storage cylinder of recovery R-500 at normal room temp (75) in the absence of non-condensable will be pressurized at
Type 1 c400
CCNA1 v3 Module 9
4
Question100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
A: What is All of the above?
Which recovery equipment maintenance practices should be performed regularly?
• Check vacuum pump for leaks• Check recovery device for leaks• Check amperage draw of recovery device
Type 1 c500
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
A: What is vacate and ventilate the spill area?
If a large leak of refrigerant occurs and no self-contained breathing apparition is available, what action should be taken?
Type 1 d100
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
A: What is they are heavier than air and displace oxygen?
Refrigerant in large quantities can cause suffocation because:
Type 1 d 200
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
A: What is recovered into its own clearly marked recovery vessels
When R- 500 is recovered from an appliance, it should be:
Type 1 d300
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
A: What is hydrochloric and hydrofluoric acid
At high temp, R-12 and r-22 can decompose to form:
Type 1 d 400
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
A: What is a a compressor or burn-out has likely occurred
Since small amounts of CFC/HCFC refrigerant have no odor, a pungent odor detected during a sealed system recovery and/or repair indicates:
Type 1 d500
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
A: What is may be vented
After recovering refrigerant from a sealed system, if nitrogen is used to pressurized or blow debris out of the system, the nitrogen:
Type 1 e100
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
A: can probably be charged back into the system?
What you do with refrigerant that has been recovered and held in refillable cylinder:
Type 1 e
200
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
What is Recover 80% of the refrigerant or achieve a 4’’ vacuum?
All recovery devices manufactured BEFORE Nov. 15, 1993 must meet these small appliance requirements:
Type 1 e 300
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
A: What is recover 90% when compressor is operating or achieve a 4” vacuum?
Type 1 e400
Small appliance recovery equipment Manufactured AFTER Nov. 15 1993 must be capable of:
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
A: What is 90% and 80%?
Small appliance recovery equipment manufactured AFTER Nov. 15, 1993 must be capable of recovering ____% with an operative compressor and ____% with a inoperative compressor?
Type 1 e500
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
A: What is a small appliance?
An appliance that is manufactured, charged, and hermetically sealed and contains less than 5 pounds of refrigerant
Type 1 f100
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
A: What is a PTAC (Pressurized terminal air conditioner)?
Common name for a hermetically sealed AC system:
Type 1 f 200
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
A: What is can be manually or automatically closed when disconnecting hoses to prevent refrigeration loss?
Low loss fittings are required on recovery equipment. What do they do?
Type 1 f 300
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
A: What are Those used in campers, recreational vehicles, or in systems built before 1950?
Which refrigerants are not covered in EPA 608?
Type 1 f 500
CCNA1 v3 Module 9
Question
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500CCNA1 v3 Module 9
A: What is self-contained or system dependant?
These 2 types of recovery devices can be used on small appliances:
Type 1 f 400
CCNA1 v3 Module 9
Question
Final Jeopardy
CCNA1 v3 Module 9
100 100 100 100 100 100
200 200 200 200 200 200
300 300 300 300 300 300
400 400 400 400 400 400
500 500 500 500 500 500