Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
CCTV POWER SUPPLIES
Lockable
cover
Air Vent
Rubberised
Cable Slots
PCS-100-9M, CCTV POWER SUPPLY
OUTPUT
DC VOLTAGE 12V
RATED CURRENT Total 8.3A 9 Channels: 0.92A for each channel
CURRENT RANGE 0—8.3A
RATED POWER 100W
DC VARIANCE (max) 120mVp-p
VOLTAGE ADJ. RANGE 11.5—13.8V
VOLTAGE TOLERANCE +/- 1.0%
LINE REGULATION +/- 0.5%
LOAD REGULATION +/- 0.5%
SETUP, RISE TIME 500ms, 20ms/230VAC at full load
HOLD UP TIME (Typ) 100ms / 230VAC at full load
INPUT
VOLTAGE RANGE 100—245 VAC
FREQUENCY RANGE 50—60Hz
EFFICIENCY (Typ) 80%
AC CURRENT (Typ) 2.5A / 115 VAC 1.5A / 230VAC
INPUT SURGE (Typ) 40A / 230VAC
LEAKAGE CURRENT <2.5mA / 240 VAC
PROTECTION
OVERLOAD 110 - 135% rated output power Protection Type: Hiccup mode, recovers automatically after fault condirion
OVER VOLTAGE
13.8 - 16.0V Protection type: hiccup mode, recovers automatically after fault condition is removed
Each output has individual fuse and LED indicator, when fault occurs, it will only affect the individual output
ENVIROMENT
WORKING TEMP -20 to +60
WORKING HUMIDITY 20 to 90% RH non-condensing
STORAGE TEMP, HUMIDITY -20 to +85, 10 to 95% RH
SAFETY
SAFETY STANDARDS CE approved
MAX VOLTAGE BETWEEN CIRCUITS
I/P—O/P: 3KVAC I/P-FG: 1.5KVAC O/P—FG: 0.5KVAC
OTHERS DIMENSION 230 X 200 X 60mm
PCS-100-9M
POWER SUPPLY
PTC
Fuse
LED
Indicator AC Input
Power Output
to camera
PTC Fuse
LED
Indicator
Universal AC Input
Short Circuit Protection / Overload / Over Voltage
LED indicator for power
2 year warranty
A PTC device comprises a non-conductive crystalline organic polymer matrix that is loaded
with particles to make it conductive. Since it is conductive it will pass a given current. If too much current is passed through the device, the device will trip.
Once fault is rectified the PTC will reset itself.
Lockable
cover
Air Vent
Rubberised
Cable Slots
PCS-180-18M, CCTV POWER SUPPLY
OUTPUT
DC VOLTAGE 12V
RATED CURRENT Total 15A 18 Channels: 0.83A for each channel
CURRENT RANGE 0—15A
RATED POWER 180W
DC VARIANCE (max) 180mVp-p
VOLTAGE ADJ. RANGE 10.8—13.2V
VOLTAGE TOLERANCE +/- 1.0%
LINE REGULATION +/- 0.5%
LOAD REGULATION +/- 0.5%
SETUP, RISE TIME 1500ms, 50ms/230VAC at full load
HOLD UP TIME (Typ) 20ms / 230VAC at full load
INPUT
VOLTAGE RANGE 100—132 VAC / 180—245VAC by switch
FREQUENCY RANGE 50—60Hz
EFFICIENCY (Typ) 82%
AC CURRENT (Typ) 4.5A / 115 VAC 2.5A / 230VAC
INPUT SURGE (Typ) 40A / 230VAC 55A /230VAC
LEAKAGE CURRENT <4.5mA / 240 VAC
PROTECTION
OVERLOAD 115- 135% rated output power Protection Type: Hiccup mode, recovers automatically after fault condirion
OVER VOLTAGE
13.8 - 16.2V Protection type: hiccup mode, recovers automatically after fault condition is removed
Each output has individual fuse and LED indicator, when fault occurs, it will only affect the individual output
ENVIROMENT
WORKING TEMP -20 to +60
WORKING HUMIDITY 20 to 90% RH non-condensing
STORAGE TEMP, HUMIDITY -20 to +85, 10 to 95% RH
SAFETY
SAFETY STANDARDS CE approved
MAX VOLTAGE BETWEEN CIRCUITS
I/P—O/P: 3KVAC I/P-FG: 1.5KVAC O/P—FG: 0.5KVAC
OTHERS DIMENSION 315 X 220 X 60mm
PCS-180-18M
POWER SUPPLY
PTC
Fuse
LED
Indicator AC Input
Power Output
to camera
PTC Fuse
LED
Indicator
Universal AC Input
Short Circuit Protection / Overload / Over Voltage
LED indicator for power
2 year warranty
A PTC device comprises a non-conductive crystalline organic polymer matrix that is loaded
with particles to make it conductive. Since it is conductive it will pass a given current. If too much current is passed through the device, the device will trip.
Once fault is rectified the PTC will reset itself.
Lockable
cover
Air Vent
Rubberised
Cable Slots
PCS-300-18M, CCTV POWER SUPPLY
OUTPUT
DC VOLTAGE 12V
RATED CURRENT Total 25A 18 Channels: 1.39A for each channel
CURRENT RANGE 0—25A
RATED POWER 300W
DC VARIANCE (max) 180mVp-p
VOLTAGE ADJ. RANGE 10.8—13.2V
VOLTAGE TOLERANCE +/- 1.0%
LINE REGULATION +/- 0.5%
LOAD REGULATION +/- 1.0%
SETUP, RISE TIME 2000ms, 60ms/230VAC at full load
HOLD UP TIME (Typ) 20ms / 230VAC at full load
INPUT
VOLTAGE RANGE 100—132 VAC / 180—245VAC by switch
FREQUENCY RANGE 50—60Hz
EFFICIENCY (Typ) 82%
AC CURRENT (Typ) 7A / 115 VAC 4A / 230VAC
INPUT SURGE (Typ) 40A / 115VAC 60A /230VAC
LEAKAGE CURRENT <4.0mA / 240 VAC
PROTECTION
OVERLOAD 115- 135% rated output power Protection Type: Hiccup mode, recovers automatically after fault condirion
OVER VOLTAGE
13.8 - 16.2V Protection type: hiccup mode, recovers automatically after fault condition is removed
Each output has individual fuse and LED indicator, when fault occurs, it will only affect the individual output
ENVIROMENT
WORKING TEMP -20 to +60
WORKING HUMIDITY 20 to 90% RH non-condensing
STORAGE TEMP, HUMIDITY -20 to +85, 10 to 95% RH
SAFETY
SAFETY STANDARDS CE approved
MAX VOLTAGE BETWEEN CIRCUITS
I/P—O/P: 3KVAC I/P-FG: 1.5KVAC O/P—FG: 0.5KVAC
OTHERS DIMENSION 315 X 220 X 60mm
PCS-300-18M
POWER SUPPLY
PTC
Fuse
LED
Indicator AC Input
Power Output
to camera
PTC Fuse
LED
Indicator
Universal AC Input
Short Circuit Protection / Overload / Over Voltage
LED indicator for power
2 year warranty
A PTC device comprises a non-conductive crystalline organic polymer matrix that is loaded
with particles to make it conductive. Since it is conductive it will pass a given current. If too much current is passed through the device, the device will trip.
Once fault is rectified the PTC will reset itself.