Centaurµs Centaurus Technical Review

Centaurµs Centaurus Technical Review. Centaurµs Centaurus Standard Features Transmission Reflection A single aperture before the sample –Targeting Manual

Embed Size (px)

DESCRIPTION

Centaurµs Centaurus Options ATR –ZnSe, Si, Ge crystals Motorized Stage Manual Stage Auto Focus Binocular Viewer MCT Detectors –Narrow, Mid, or Wide band

Citation preview

Page 1: Centaurµs Centaurus Technical Review. Centaurµs Centaurus Standard Features Transmission Reflection A single aperture before the sample –Targeting Manual

Centaurµs

Centaurus

Technical Review

Page 2: Centaurµs Centaurus Technical Review. Centaurµs Centaurus Standard Features Transmission Reflection A single aperture before the sample –Targeting Manual

Centaurµs

Centaurus Standard Features

• Transmission• Reflection• A single aperture before the sample

– Targeting• Manual focus• Manual Full Field (Glass) Aperture• Simultaneous View and IR• Integrated Video• Integrated Contact alert

Page 3: Centaurµs Centaurus Technical Review. Centaurµs Centaurus Standard Features Transmission Reflection A single aperture before the sample –Targeting Manual

Centaurµs

Centaurus Options

• ATR– ZnSe, Si, Ge crystals

• Motorized Stage• Manual Stage• Auto Focus• Binocular Viewer• MCT Detectors

– Narrow, Mid, or Wide band

Page 4: Centaurµs Centaurus Technical Review. Centaurµs Centaurus Standard Features Transmission Reflection A single aperture before the sample –Targeting Manual

Centaurµs

Centaurus Specifications• 10x optics

– N.A. = 0.71• Video and Field of View matched

– 600 x 450um• IR Spot size 200um• Working distance

– 9mm• Angle of Incidence

– 44°- 19°• Magnification 100x

Page 5: Centaurµs Centaurus Technical Review. Centaurµs Centaurus Standard Features Transmission Reflection A single aperture before the sample –Targeting Manual

Centaurµs

Signal to Noise

• 2 minute collect at a resolution of 4 cm-1, triangular apodization, 1.0 mm square aperture with MCT A mid-band detector on Nexus

• Transmission mean average .028peak to peak– Signal to noise ratio 3000 to 1

• Reflection mean average .065 peak to peak– Signal to noise ratio 1500 to 1

Page 6: Centaurµs Centaurus Technical Review. Centaurµs Centaurus Standard Features Transmission Reflection A single aperture before the sample –Targeting Manual

Centaurµs

Field of View

Field of Viewis 600 x 450micrometers

Matches thebinocularviewer

Page 7: Centaurµs Centaurus Technical Review. Centaurµs Centaurus Standard Features Transmission Reflection A single aperture before the sample –Targeting Manual

Centaurµs

• 12 um Kevlar™ fiber

Page 8: Centaurµs Centaurus Technical Review. Centaurµs Centaurus Standard Features Transmission Reflection A single aperture before the sample –Targeting Manual

Centaurµs

Superior performance of Targeting™ in a Single Aperturing

SystemKevlar 12 um fiber on Hammer12 micron kevlar - single aperture IRus after the sample

15

20

25

30

35

40

45

50

55

%T

1000 1500 2000 2500 3000 3500 Wavenumbers (cm-1)

12 µm fiber

12 x 40 µm aperture

Targeting Vs. single aperture after the sample

Page 9: Centaurµs Centaurus Technical Review. Centaurµs Centaurus Standard Features Transmission Reflection A single aperture before the sample –Targeting Manual

Centaurµs

Dark Mirror CoatingEliminates HeNe

12

14

16

18

20

22

24

26

28

30

32

34

36

38

40

42

Sin

gle

Bea

m

1000 2000 3000 4000 Wavenumbers (cm-1)

Blocks HeNe

Reflects IR Radiation 98% of Gold

Page 10: Centaurµs Centaurus Technical Review. Centaurµs Centaurus Standard Features Transmission Reflection A single aperture before the sample –Targeting Manual

Centaurµs

Transmission

• Multi layered laminate• 4 layers• 30 to 60 um layers Polypropylene layer 3

50

100

%T

Layer 4 Polyester

50%T

Layer 1 Polyester

20

40

60

80

%T

Polypropylene layer 2

50

100

%T

1000 2000 3000 Wavenumbers (cm-1)

Page 11: Centaurµs Centaurus Technical Review. Centaurµs Centaurus Standard Features Transmission Reflection A single aperture before the sample –Targeting Manual

Centaurµs

Transmission Nylon fiber

5 10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

95

%R

efle

ctan

ce

1000 2000 3000 Wavenumbers (cm-1)

Nylon Fiber

Page 12: Centaurµs Centaurus Technical Review. Centaurµs Centaurus Standard Features Transmission Reflection A single aperture before the sample –Targeting Manual

Centaurµs

Palm Oil Palm Oil

10

20

30

40

50

60

70

80

90

100

110

%Tr

ansm

ittan

ce

1000 2000 3000 Wavenumbers (cm-1)

Page 13: Centaurµs Centaurus Technical Review. Centaurµs Centaurus Standard Features Transmission Reflection A single aperture before the sample –Targeting Manual

Centaurµs

Reflection

• External Reflection– Reflection absorption– Specular Reflection

• Internal reflection (ATR) – Znse, Ge, and Si

Page 14: Centaurµs Centaurus Technical Review. Centaurµs Centaurus Standard Features Transmission Reflection A single aperture before the sample –Targeting Manual

Centaurµs

Specular ReflectionApoxy Resin

Alkyd resin specular

2.0

2.5

3.0

3.5

4.0

4.5

5.0

%T

Converted spectrum

0.0

0.2

0.4

0.6

0.8

1.0

Abs

orba

nce

1000 1500 2000 2500 3000 3500 Wavenumbers (cm-1)

Page 15: Centaurµs Centaurus Technical Review. Centaurµs Centaurus Standard Features Transmission Reflection A single aperture before the sample –Targeting Manual

Centaurµs

Reflection Absorbtion

• High signal to noise

• 30 second acquisition time

beeswax chapstick

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

%R

efle

ctan

ce

1000 2000 3000 Wavenumbers (cm-1)

Page 16: Centaurµs Centaurus Technical Review. Centaurµs Centaurus Standard Features Transmission Reflection A single aperture before the sample –Targeting Manual

Centaurµs

ATR

• ZnSe, Ge, Si• Energy throughput comparable to

InspectIR • Frequency test using Toluene• No spectral artifacts

Page 17: Centaurµs Centaurus Technical Review. Centaurµs Centaurus Standard Features Transmission Reflection A single aperture before the sample –Targeting Manual

Centaurµs

ATR Frequency/Artifacts TestTransmission SI crystal Ge crystal ZnSe crystal

3028 cm-1 3028 cm-1 3028 cm-1 3028 cm-1

1495 cm-1 1495 cm-1 1495 cm-1 1495 cm-1

728 cm-1 728 cm-1 728 cm-1 728 cm-1

Hammer ATR GE crystal Toluene 200 um aperture

0.0

0.2

0.4

0.6

0.8

Abs

Hammer toluene SI ATR 200 um aperture

0.0

0.2

0.4

0.6

0.8

Abs

Hammer ATR ZnSe Toluene 200 um aperture

0.0

0.2

0.4

0.6

0.8

Abs

800 1000 1200 1400 1600 1800 Wavenumbers (cm-1)

Page 18: Centaurµs Centaurus Technical Review. Centaurµs Centaurus Standard Features Transmission Reflection A single aperture before the sample –Targeting Manual

Centaurµs

ZnSe ATR Ink on Business Card

40

45

50

55

60

65

70

75

80

85

90

95

100

%T

rans

mitt

ance

1000 1500 2000 2500 3000 3500 Wavenumbers (cm-1)

High signal to noise

Equivalent Performance to InspectIR

Use with or without aperture

Page 19: Centaurµs Centaurus Technical Review. Centaurµs Centaurus Standard Features Transmission Reflection A single aperture before the sample –Targeting Manual

Centaurµs

Si ATR CrystalWed Jan 03 10:10:45 2001Red layer

86

88

90

92

94

96

98

%R

efle

ctan

ce

Wed Jan 03 10:12:31 2001Blue layer

70

75

80

85

90

95

%R

efle

ctan

ce

1000 2000 3000 Wavenumbers (cm-1)

Page 20: Centaurµs Centaurus Technical Review. Centaurµs Centaurus Standard Features Transmission Reflection A single aperture before the sample –Targeting Manual

Centaurµs

GE ATR Crystal• Shallow depth of penetration• Good for carbon or filled samples

Antihistomine Ge

0.00

0.01

0.02

0.03

0.04

0.05

0.06

0.07

0.08

0.09A

bsor

banc

e

1000 2000 3000 Wavenumbers (cm-1)