CENTERLINE 2500 Low Voltage Motor Control Centers and
-
Upload
others
-
View
1
-
Download
0
Embed Size (px)
Citation preview
CENTERLINE 2500 Low Voltage Motor Control Centers and Power
Distribution Gear Catalog Structure BreakdownTechnical Data
CENTERLINE 2500 Low Voltage Motor Control Centers and Power
Distribution Gear Catalog Structure Breakdown Catalog Numbers
2500
CENTERLINE 2500 Low Voltage Motor Control Centers and Power
Distribution Gear Catalog Structure Breakdown
Table of Contents
You can view or download publications at
http://www.rockwellautomation.com/literature/. To order paper
copies of technical documentation, contact your local Allen-Bradley
distributor or Rockwell Automation sales representative.
Topic Page
Additional Resources 2
Ordering a CENTERLINE 2500 Low Voltage Motor Control Center (MCC)
3
Step 1: Ordering a Column 3
Step 2: Ordering a Unit 5
Bulletin 2507 - Direct Online Reversing (DOLR) Starter Units
6
Bulletin 2513 - Direct Online (DOL) Non-reversing Starter Units
7
Bulletins 2593M - Main Units 8
Bulletin 2593F - Feeder Units 10
PowerFlex Variable Frequency Drive (VFD) Units 12
Bulletin 2563T - PowerFlex 40 VFD Unit Catalog Number Explanation
13
Bulletin 2563U - PowerFlex 753 VFD Unit Catalog Number Explanation
14
Bulletin 2563V - PowerFlex 755 VFD Unit Catalog Number Explanation
15
Catalog Number Explanation Tables 16
Resource Description
CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear
Assemblies Selection Guide, publication 2500-SG001
Provides detailed information on selecting and ordering a
CENTERLINE 2500 low voltage motor control center.
PowerFlex Low Voltage AC Drives Selection Guide, publication
PFLEX-SG002 Provides detailed information on selecting and ordering
PowerFlex 40 and 750-series low voltage AC drives.
CENTERLINE 2500 Low Voltage Motor Control Centers Installation
Instructions, publication 2500-IN001
Provides detailed information on installing a CENTERLINE 2500 low
voltage motor control center.
Product Certifications website,
http://www.rockwellautomation.com/rockwellautomation/certification/
2 Rockwell Automation Publication 2500-TD004A-EN-P - September
2013
Ordering a CENTERLINE 2500 Low Voltage Motor Control Center
(MCC)
This publication details two catalog number structures needed to
order a CENTERLINE 2500 MCC. The first step is to determine the
catalog number structure for column configuration where you first
determine column size and design before you fit it with
units.
The second step is to determine the catalog number structure for
unit configuration where you determine which units are needed for
your application and will be housed in the column.
Preferred Lead Time Items
Both catalog number structures include preferred lead time items,
which are items that are readily available and do not add any lead
time to the building of your CENTERLINE 2500 MCC.
Table cells highlighted in blue signify preferred lead time items.
In the example in Figure 1, three of the five available code
selections in the table are preferred lead time items.
Figure 1 - Preferred Lead Time Items Example
Step 1: Ordering a Column
Use the following information for each CENTERLINE 2500 MCC column
that you order.
Figure 2 - Column Catalog Number Structure
Column Width
Column Height
Column Horizontal
Keyed withdrawable 5
2500 – 3 6108 B L E 1 1 L A 12 U 00 G B G 3 U 3 U 3 U * Column
Setup Horizontal Bus Bar Vertical Bus Bar Options(1)
(1) Column options are currently unavailable.
Column Type
Rockwell Automation Publication 2500-TD004A-EN-P - September 2013
3
CENTERLINE 2500 Low Voltage Motor Control Centers and Power
Distribution Gear Catalog Structure Breakdown
Column Catalog Number Explanation
Capacity (Amps) Code
Column Setup Horizontal Bus Bar Vertical Bus Bar Options
2500 – 3 6108 B L E 1 1 L A 12 U 00 G B G 3 U 3 U 3 U * See table:‡
a b c d Currently
Unavailable
Configuration Code
Fixed 1
6
7
Not resistant X
Bus Material
Material Code
Silver-plated copper(1)
(1) Available for all horizontal, vertical, neutral, and ground bus
bars.
G
(2) Available only for horizontal and horizontal neutral bus
bars.
H
S
U
Capacity (Amps) Code
4 Rockwell Automation Publication 2500-TD004A-EN-P - September
2013
CENTERLINE 2500 Low Voltage Motor Control Centers and Power
Distribution Gear Catalog Structure Breakdown
Step 2: Ordering a Unit Each CENTERLINE 2500 MCC product in this
publication uses a catalog number structure that you fill out to
order that product. See the figure below on how to use a unit’s
catalog number structure.
Figure 3 - Unit Catalog Number Structure Example
25xx – B 3 L A QL5 BTY R 1 1 2 * * * * * Common Unit Structure Unit
Specific Suffix Options
These selections are available to all unit types. These selections
vary by unit type. These selections are engineered options that can
be added to certain unit types. They are currently
unavailable.
Voltage Configure
Pole Configure
Rockwell Automation Publication 2500-TD004A-EN-P - September 2013
5
CENTERLINE 2500 Low Voltage Motor Control Centers and Power
Distribution Gear Catalog Structure Breakdown
Bulletin 2507 - Direct Online Reversing (DOLR) Starter Units
These combination direct online reversing starter units are
supplied with Allen-Bradley Bulletin 104C or 104D contactors and a
circuit breaker disconnect. The starters are mechanically and
electrically interlocked to avoid both contactors being closed
simultaneously.
These units are available with an E1 Plus or E3 Plus overload relay
and available with or without an external reset button for the
overload relay.
Bulletin 2507 Catalog Number Explanation
DOLR starter with circuit breaker
Common Unit Structure Unit Specific Suffix Options
2507 – B 3 L A QL5 BTY R 1 1 2 E C037 C22 E1FF * See table:‡ b e f
c d g i Currently
Unavailable
Standard arc resistant(1) C
T-handle arc resistant(1) D
6 Rockwell Automation Publication 2500-TD004A-EN-P - September
2013
CENTERLINE 2500 Low Voltage Motor Control Centers and Power
Distribution Gear Catalog Structure Breakdown
Bulletin 2513 - Direct Online (DOL) Non-reversing Starter
Units
Direct online non-reversing starter units are supplied with Allen-
Bradley Bulletin 100C or 100D contactors and either a fusible or
circuit breaker disconnect. These units are available with a E1
Plus or E3 Plus overload relay and available with or without an
external reset button for the overload relay.
Bulletin 2513 Catalog Number Explanation
DOL non-reversing starter with circuit breaker
Common Unit Structure Unit Specific Suffix Options
2513 – B 3 L A QL5 BTY R 1 1 2 E C037 C22 E1FF * See table:‡ b e f
c d g i Currently
Unavailable
Standard arc resistant(1)
C
Rockwell Automation Publication 2500-TD004A-EN-P - September 2013
7
CENTERLINE 2500 Low Voltage Motor Control Centers and Power
Distribution Gear Catalog Structure Breakdown
Bulletins 2593M - Main Units
Main units provide a lug connection for incoming lines (mains) to
distribute power to the motor control center. Lug compartments are
available in ratings from 300…4000 A and are fixed mounted. Lug
compartments are available in either top or bottom entry.
Mechanical or crimp style lugs are available. The compartments are
front accessible for easy maintenance and thermography
checks.
Molded-case circuit breakers (MCCB) are available for main circuit
breaker units. The MCCB main units are available with a thermal
magnetic trip circuit breaker up to 1200 A and an electronic trip
circuit breaker 50 A and above. The main circuit breaker units are
fixed mounted for all ratings.
MCCB units are front accessible with removable protective barriers
on the line side, reducing the possibility of accidental contact
with line terminals.
Air circuit breaker (ACB) units are front accessible with removable
protective barriers on the line side, reducing the possibility of
accidental contact with line terminals. ACBs offer short circuit
protection and disconnect means. When opened, the breaker contacts
are rapidly swung into a small sealed chamber causing the displaced
air to blow out the arc. They are critical components in switchgear
mains, feeders and main-tie-mains.
The ACB compartments have trip ratings available from 400 to 4000
A. These ACBs are available with a drawout or fixed style. The ACBs
for mains include an option to use 4-pole breakers. ACBs can be
integrated into auto-transfer switch schemes such as main-main or
main-tie-main schemes. Top or bottom mounting is available.
The ACBs are available with enclosure ratings of IP 20, IP 42, and
IP 54.
L1
L2
L3
N
L1
-QF1
8 Rockwell Automation Publication 2500-TD004A-EN-P - September
2013
CENTERLINE 2500 Low Voltage Motor Control Centers and Power
Distribution Gear Catalog Structure Breakdown
Bulletin 2593M Catalog Number Explanation
Door Latch
Type Code
Standard arc resistant(1)
C
Common Unit Structure Unit Specific Suffix Options
2593M – B 3 L A QL5 BTY R 1 1 2 C40 2 A * See table:‡ b e f c d h
Currently
Unavailable
6
7
Rockwell Automation Publication 2500-TD004A-EN-P - September 2013
9
CENTERLINE 2500 Low Voltage Motor Control Centers and Power
Distribution Gear Catalog Structure Breakdown
Bulletin 2593F - Feeder Units
Feeder units provide a lug connection for outgoing cables (feeders)
to feed power from the motor control center to an external load.
Lug compartments are available in ratings from 300…4000 A and are
fixed mounted. Lug compartments are available in either top or
bottom entry. Mechanical or crimp style lugs are available. The
compartments are front accessible for easy maintenance and
thermography checks.
Molded-case circuit breakers (MCCB) are available for feeder
circuit breaker units. The MCCB feeder units are available in a
withdrawable unit style up to 225 A and are fixed mounted for
ratings 250 A and above.
MCCB units are front accessible with removable protective barriers
on the line side, reducing the possibility of accidental contact
with line terminals.
Air circuit breaker (ACB) units are front accessible with removable
protective barriers on the line side, reducing the possibility of
accidental contact with line terminals. ACBs offer short circuit
protection and disconnect means. When opened, the breaker contacts
are rapidly swung into a small sealed chamber causing the displaced
air to blow out the arc. They are critical components in switchgear
mains, feeders and main-tie-mains.
The ACB compartments have trip ratings available from 400 to 4000
A. These ACBs are available with a drawout or fixed style. ACBs can
be integrated into auto-transfer switch schemes such as main-main
or main-tie-main schemes. Top or bottom mounting is
available.
The ACBs are available with enclosure ratings of IP 20, IP 42, and
IP 54.
L1
L2
L3
N
1
-QF1
10 Rockwell Automation Publication 2500-TD004A-EN-P - September
2013
CENTERLINE 2500 Low Voltage Motor Control Centers and Power
Distribution Gear Catalog Structure Breakdown
Bulletin 2593F Catalog Number Explanation
Common Unit Structure Unit Specific Suffix Options
2593F – B 3 L A QL5 BTY R 1 1 2 C40 2 A * See table:‡ b e f c d h
Currently
Unavailable
6
7Door Latch
Type Code
Standard arc resistant(1)
C
Rockwell Automation Publication 2500-TD004A-EN-P - September 2013
11
CENTERLINE 2500 Low Voltage Motor Control Centers and Power
Distribution Gear Catalog Structure Breakdown
PowerFlex Variable Frequency Drive (VFD) Units
The combination drive units for the CENTERLINE 2500 Motor Control
Centers contain a variable frequency AC drive and either a fusible
or circuit breaker disconnect.
Available standard models include: • PowerFlex 40 • PowerFlex 753 •
PowerFlex 755
PowerFlex drive features include: • Isolated logic and power • A
three-phase, pulse width modulated (PWM) adjustable frequency
output and voltage output for exceptional
control of motor speed and torque • Access to mode programming,
providing precise and repeatedly accurate setup, control and
operation, and
adaptability to handle a variety of applications
PowerFlex drive with a circuit breaker without a line or load
reactor
PowerFlex drive with a circuit breaker with a line reactor
PowerFlex drive with a circuit breaker with a load reactor
PowerFlex drive with a circuit breaker with a line and load
reactor
12 Rockwell Automation Publication 2500-TD004A-EN-P - September
2013
CENTERLINE 2500 Low Voltage Motor Control Centers and Power
Distribution Gear Catalog Structure Breakdown
Bulletin 2563T - PowerFlex 40 VFD Unit Catalog Number
Explanation
Common Unit Structure
Unit Specific Suffix Options
2563T – B 3 K A QL5 BTY R 1 1 2 E * ** See table:‡ b e f c d
Currently
Unavailable p
Pole Configuration
Poles Code
3-pole 3
Ingress Protection
Rating Code
IP54 J
IP42 K
IP20 L
Handle Operation
Standard arc resistant(1)
C
Rockwell Automation Publication 2500-TD004A-EN-P - September 2013
13
CENTERLINE 2500 Low Voltage Motor Control Centers and Power
Distribution Gear Catalog Structure Breakdown
Bulletin 2563U - PowerFlex 753 VFD Unit Catalog Number
Explanation
Common Unit Structure
Unit Specific Suffix Options
2563U – B 3 L A QL5 BTY R 1 1 2 E * ** See table:‡ b e f c d
Currently
Unavailable p
Pole Configuration
Poles Code
3-pole 3
Ingress Protection
Rating Code
IP54 J
IP42 K
IP20 L
Handle Operation
Standard arc resistant(1)
C
14 Rockwell Automation Publication 2500-TD004A-EN-P - September
2013
CENTERLINE 2500 Low Voltage Motor Control Centers and Power
Distribution Gear Catalog Structure Breakdown
Bulletin 2563V - PowerFlex 755 VFD Unit Catalog Number
Explanation
Common Unit Structure
Unit Specific Suffix Options
2563T – B 3 L A QL5 BTY R 1 1 2 E * ** See table:‡ b e f c d
Currently
Unavailable p
Pole Configuration
Poles Code
3-pole 3
Ingress Protection
Rating Code
IP54 J
IP42 K
IP20 L
Handle Operation
Standard arc resistant(1)
C
Rockwell Automation Publication 2500-TD004A-EN-P - September 2013
15
CENTERLINE 2500 Low Voltage Motor Control Centers and Power
Distribution Gear Catalog Structure Breakdown
Catalog Number Explanation Tables
Wiring System Form Code Wiring System Form Code
Wire 3 wire 2 a A No wire 3 wire 2 a M
b B b N
b D b P
b F b R
4 wire 2 a G 4 wire 2 a S
b H b T
b J b V
b L b X
Munsell N 9.5 3
Table e is on page 17.
d Available Colors, Internal
Color Code Color Code
Munsell N 9.5 3
f Circuit Breaker Protection
140M H/J/L Magnetic BAY
16 Rockwell Automation Publication 2500-TD004A-EN-P - September
2013
CENTERLINE 2500 Low Voltage Motor Control Centers and Power
Distribution Gear Catalog Structure Breakdown
Catalog Number Explanation Tables, continued
Coil Control Codes
Line Voltage
Coil (control)
Frequency (Hz)
Individual Control
Separate Control
110V AC 50 ND5 AD5 60 ND6 AD6
115V AC 50 NE5 AE5 60 NE6 AE6
120V AC 50 NF5 AF5 60 NF6 AF6
220V AC 50 NL5 AL5 60 NL6 AL6
230V AC 50 NM5 AM5 60 NM6 AM6
240V AC 50 NN5 AN5 60 NN6 AN6
415 24V DC 50 FJ5 DJ5 60 FJ6 DJ6
110V AC 50 FD5 DD5 60 FD6 DD6
115V AC 50 FE5 DE5 60 FE6 DE6
120V AC 50 FF5 DF5 60 FF6 DF6
220V AC 50 FL5 DL5 60 FL6 DL6
230V AC 50 FM5 DM5 60 FM6 DM6
240V AC 50 FN5 DN5 60 FN6 DN6
440 24V DC 50 QJ5 EJ5 60 QJ6 EJ6
110V AC 50 QD5 ED5 60 QD6 ED6
115V AC 50 QE5 EE5 60 QE6 EE6
120V AC 50 QF5 EF5 60 QF6 EF6
220V AC 50 QL5 EL5 60 QL6 EL6
230V AC 50 QM5 EM5 60 QM6 EM6
240V AC 50 QN5 EN5 60 QN6 EN6
N D 5
Line Control Codes
Line (system) Voltage
Individual Control Code
Separate Control Code
380(1) N A
400(1)
(1) Typically for engineered to order (ETO) units. Contact your
local Allen-Bradley distributor for delivery lead times.
K C
e
IMPORTANT Additional power and control wiring options are
configurable by using the code builder (below right). However, only
codes highlighted in the table (below left) are preferred lead time
items.
Rockwell Automation Publication 2500-TD004A-EN-P - September 2013
17
CENTERLINE 2500 Low Voltage Motor Control Centers and Power
Distribution Gear Catalog Structure Breakdown
Catalog Number Explanation Tables, continued g
Power Configuration
18 Rockwell Automation Publication 2500-TD004A-EN-P - September
2013
CENTERLINE 2500 Low Voltage Motor Control Centers and Power
Distribution Gear Catalog Structure Breakdown
Catalog Number Explanation Tables, continued
C2 A Z
Product Model Code Full Load Current
Range (amps) Code Feature Code E1 — E1 0.1 - 0.5 A Thermistor
A
0.2 - 1.0 B Ground fault current B
1.0 - 5.0 C Jam C
3.2 - 16 D Ground fault and jam D
5.4 - 27 E Remote reset E
9 - 45 F EtherNet/IP F
18 - 90 G DeviceNet G
60 - 300 J Profibus H
120 - 600 K No option Z
E3 EC1 C1 0.4 - 2.0 P EtherNet/IP A EC2 C2 1.0 - 5.0 A No option Z
EC3 C3 3.0 - 15 B — EC4 C4 5.0 - 25 C EC5 C5 9.0 - 45 D
18 - 90 E
42 - 210 G
60 - 302 H
84 - 420 J
Product Operator Interface
Sensing Features Code
Digital Modes
Analog Mods Code
E300 LCD I 3A 300 3 0 0 A I, G 3B 600 6 1 B
I, G, V 3C 1000 1 2 C LED I 3D 2000 2 3 D
I, G 3E — 4 E
I, G, V 3F — 1 0 F
None I 3G — 1 G
I, G 3H — 2 H
I, G, V 3I — 3 I
4 J 2 0 K
1 L 2 M 3 N 4 O
3 0 P 1 Q 2 R 3 S 4 T
4 0 U 1 V 2 W 3 X 4 Y
i
IMPORTANT All four code digits must be from highlighted cells to be
a preferred lead time item.
Rockwell Automation Publication 2500-TD004A-EN-P - September 2013
19
Allen-Bradley, CENTERLINE, LISTEN.THINK.SOLVE., PowerFlex, Rockwell
Automation, and Rockwell Software are trademarks of Rockwell
Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of
their respective companies.
Publication 2500-TD004A-EN-P - September 2013 Supersedes
Publication XXXX-X.X.X - Month Year Copyright © 2013 Rockwell
Automation, Inc. All rights reserved. Printed in the U.S.A.
Important User Information
Read this document and the documents listed in the additional
resources section about installation, configuration, and operation
of this equipment before you install, configure, operate, or
maintain this product. Users are required to familiarize themselves
with installation and wiring instructions in addition to
requirements of all applicable codes, laws, and standards.
Activities including installation, adjustments, putting into
service, use, assembly, disassembly, and maintenance are required
to be carried out by suitably trained personnel in accordance with
applicable code of practice.
If this equipment is used in a manner not specified by the
manufacturer, the protection provided by the equipment may be
impaired.
In no event will Rockwell Automation, Inc. be responsible or liable
for indirect or consequential damages resulting from the use or
application of this equipment.
The examples and diagrams in this manual are included solely for
illustrative purposes. Because of the many variables and
requirements associated with any particular installation, Rockwell
Automation, Inc. cannot assume responsibility or liability for
actual use based on the examples and diagrams.
No patent liability is assumed by Rockwell Automation, Inc. with
respect to use of information, circuits, equipment, or software
described in this manual.
Reproduction of the contents of this manual, in whole or in part,
without written permission of Rockwell Automation, Inc., is
prohibited.
Documentation Feedback
Your comments will help us serve your documentation needs better.
If you have any suggestions on how to improve this document,
complete this form, publication RA-DU002, available at
http://www.rockwellautomation.com/literature/.
Rockwell Otomasyon Ticaret A.., Kar Plaza Merkezi E Blok Kat:6
34752 çerenköy, stanbul, Tel: +90 (216) 5698400
Ordering a CENTERLINE 2500 Low Voltage Motor Control Center
(MCC)
Preferred Lead Time Items
Column Catalog Number Explanation
Bulletin 2507 - Direct Online Reversing (DOLR) Starter Units
Bulletin 2507 Catalog Number Explanation
Bulletin 2513 - Direct Online (DOL) Non-reversing Starter
Units
Bulletin 2513 Catalog Number Explanation
Bulletins 2593M - Main Units
Bulletin 2593F - Feeder Units
PowerFlex Variable Frequency Drive (VFD) Units
Bulletin 2563T - PowerFlex 40 VFD Unit Catalog Number
Explanation
Bulletin 2563U - PowerFlex 753 VFD Unit Catalog Number
Explanation
Bulletin 2563V - PowerFlex 755 VFD Unit Catalog Number
Explanation
Catalog Number Explanation Tables a, b, c, d, and f
Table e
Table i
Back Page
Introduction_Category Types
This tab summarizes Rockwell Automation Global Sales and Marketing
preferred printing standards. It also provides guidance on whether
a publication should be released as JIT (print on demand) or if it
requires an RFQ for offset printing. Find your publication type in
the first section below. Use the assigned Printing Category
information to determine the standard print specifications for that
document type. The Printing Categories are defined below the
Publication Type section. Note there may be slightly different
print specifications for the categories, depending on the region
(EMEA or Americas). For more information on Global Sales and
Marketing Printing Standards, see publication RA-CO004 in
DocMan.
Publication Type and Print Category
Publication Type
JIT Spec. (See table below)
Description
AD
5
100
(press releases should not be checked into DocMan or printed)
AT
PP
A3
D1
Profile (Single Product or Service). NOTE: Application Solutions
are to be assigned the AP pub type.
5
100
NA
Sales Promotion NOTE: Service profiles are to be assigned the PP
pub type.
5
100
D5, D6
Technical Data
Presale / External
** Minimum order quantities on all JIT items are based on the
publication length. **
Publication length
33 to 76 pages
Pre-sale / Marketing
All paper in this category is White Brightness, 90% or better.
Opacity 90% or better
Category
A1
A2
A3
80# gloss cover, 80# gloss text
A4
A5
A6
A7
Category being deleted
A8
2 color text
Selection Guide
Post Sale / Technical Communication
B1
B3
B4
B5
Catalogs
Category
C1
JIT / POD
All paper in this category is White Brightness, 82% or better.
Opacity 88% or better
Category
D1
D2
D3
80# gloss cover, 80# gloss text coated 2 sides
D4
90# index, 20# bond
90# index, 20# bond
Cover 160gsm with Body 80gsm
90# index, 20# bond
Just In Time (JIT) or Off Set (OS)?
Use these guidelines to determine if your publication should be JIT
(just in time/print on demand) or if it would be more economical to
print OS (offset/on a press). OS print jobs require an RFQ (Request
For Quote) in US. If your job fits into the “Either” category, an
RFQ is recommended, but not required. In the US, RA Strategic
Sourcing will discourage or reject RFQs for jobs that fall within
the JIT category. Guidelines differ for black & white and color
printing, so be sure to check the correct tables.
Black & White Printing
Publication Title:
CENTERLINE 2500 Low Voltage Motor Control Centers and Power
Distribution Gear Catalog Structure Breakdown
Sample: ElectroGuard Selling Brief 80 character limit - must match
DocMan Title
8.25” x 11” (RA product profile std)
PLASTCOIL - Plastic Coil (Coil Bound)
A4
BOTTOM
SIDE
NO
YES or NO - If Yes, must have Part No. listed below
8.25” x 10.875”
STAPLED1 -1 position
Part Number:
If SAP Part Number, be sure to enter PN- before the number
7.385” x 9” (RSI Std)
STAPLED1B - bottom 1 position
(required) Category
Pre-sale / Marketing
Select Print Category A,B,C or D from category list, on
"Introduction_Category Types" tab
6” x 4”
STAPLED2 - 2 positions
5.5” x 8.5” (half-size)
A7
Ink Color:
One color assumes BLACK / 4 color assume CMYK / Indicate PMS number
here
4.75” x 7.75”
A8
20
Total page count including cover. Enter PAGE count, not SHEET
count
4.75” x 7” (slightly smaller half-size)
A9
8.5” x 11”
4.25" x 5.50"
Review key below. Leave blank if folded for saddle stitching
4” x 6”
3” x 5”
A4 (8 ¼” x 11 ¾”) (210 x 297 mm)
B4
Drill Hole (Yes/No):
All drilled publications use the 5-hole standard, 5/16 inch-size
hole and a minimum of ¼ inch from the inner page border.
A5 (5.83” x 8.26”) (148 x 210 mm)
B5
36” x 24” Poster
Average sheets of paper. 25, 50 75,100 Max
24” x 36” Poster
(required) Business Group:
(required) Cost Center:
19134- Power Control
If your Business Unit is Marketing Commercial, add the appropriate
division name after 19134 using the chart on the right. All other
Business Units: Enter only the number as in DocMan, no description.
Example - 19021
19134 - Commerc 19134 - OEM 19134 - Compone 19134 - Power C 19134 -
Global 19134 - Process 19134 - IA 19134 - Service 19134 - IMC 19134
- Safety 19134 - Industr 19134 - Softwar 19134 - Mkt Dig 19134 - US
Marke
D1
Microfold or French Fold - designate no. of folds in Comments -
intended for single sheet only to be put in box for
manufacturing
Comments:
D2
Double Gate
Folds Half, V, Single C or Tri Dble Parll Z or Accordian Microfold
or French Double Gate Short Fold
Saddle-Stitch Items All page quantities must be divisible by 4.
Note: Stitching is implied for Saddle-Stitch - no need to specify
in Stitching Location. 80 pgs max. on 20# (text and cover) 76 pgs
max. on 20# (text) and 24# (cover) 72 pgs max. on 24# (text and
cover) Perfect Bound Items 940 pgs max. w/cover (90# index unless
indicated otherwise) 70 pgs. min. for spine without words 200 pgs
min. for spine with words Plastcoil Bound Items 530 pgs max. of 20#
(if adding cover deduct equivalent number of pages to equal cover
thickness) (90# index unless indicated otherwise) Tape Bound Items
250 pgs max. on 20# no cover 240 pgs max. w/cover (90# index unless
indicated otherwise)
MBD000B0209.bin
MBD000B020B.bin
MBD000B020C.bin
MBD000B020A.bin
MBD000B0205.bin
MBD000B0207.bin
MBD000B0208.bin
MBD000B0206.bin
MBD000B0203.bin
MBD000B0204.bin