Central Data Bank List of Building Materials
A. General
Department: Buildings
Type of building material: Fire protection materials for structural use
Applications: For protection of structural elements to resist the action of fire for the specified periods
B. Acceptance criteria
Testing standards: Fire test/assessment should be carried out in accordance with BS 476: Parts 20 to 24: 1987.
Conditions of Acceptance: • To satisfy section 6.5 of the Code of Practice for Fire Resisting
Construction 1996, valid and full fire test/assessment report shall be submitted to demonstrate that the concerned product or material has been tested in accordance with or assessed against BS 476: Parts 20 to 24: 1987 by a laboratory accredited under HOKLAS or recognized under mutual recognitionagreements/arrangements with HOKLAS, or one of the assessing organizations listed in PNAP 251.
• Details of application such as surface preparation, application ofprimer, top coating etc, shall be strictly in accordance with themanufacturer’s specifications/recommendations and arecompatible with those adopted in the fire tests.
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
001
Bollom
Fireshield
J.W. Bollom &
Company Limited
(See remarks)
Intumescent Coating Protection of
steel I-beams up
to 11/2 hrs. FRP;
steel I-columns,
CHS & RHS
columns up to 1
hr. FRP.
BS 476: Parts 20
& 21: 1987
N/A The Loss
Prevention
Council
CC81169 May 1991 May 1993 18/01/2005 No-objection letter
issued in 1991.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire protection coating
should be in
accordance with
appendix 2 of the
report no. CC81169.
BD-FP
002 Cafco 280,
800 & Cafco
Blaze-Shield
Isolatek
International
(See remarks)
Cementitious
mineral fibre
Protection of
steel beams and
columns up to 4
hrs. FRP.
BS 476: Parts 20
& 21: 1987
N/A The Loss
Prevention
Council
376.3 December
1993
January 1997 18/01/2005 No-objection letter
issued in 1994.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Thickness of fire
protection material
should be in
accordance with data
sheets attached to BD’s
letter Ref. (37) in BD
GR/BM/2(23).
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
003
Cafco 280 Cafco Europe Sarl
Foetz,
Luxembourg
Cementitious
mineral fibre
Upgrade
structural
concrete slab up
to 4 hrs. FRP.
BS 476: Parts 20
& 21: 1987
BS 8110: Part 2:
1985
N/A Warrington
Fire Research
Centre
WFRC No.
C81024
January 1994 March 1998 18/01/2005 No-objection letter
issued in 1996.
Required thickness of
fire protection material
should be in
accordance with Tables
1, 2 & 3 in the
assessment report
WFRC No. C81024.
Both structural stability
and insulation
requirements should be
considered and the
higher of the thickness
applied.
BD-FP
004 Cape Supalux
Board
Cape Building
Products Limited
(See remarks)
Fibre reinforced
calcium silicate
board
2 hrs. fire
protection to
timber floor in
terms of load
bearing capacity,
integrity and
insulation.
As the system
does not form an
integral part of
the structure, the
actual
application and
acceptability of
the system
should be
considered on a
job-by-job basis.
BS 476: Parts 20
& 21: 1987
N/A The Loss
Prevention
Council
TE6640 January 1989 N/A 18/01/2005 No-objection letter
issued in 1993.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
The fire protection
system shall be as
described in the report
no. TE6640.
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
005
Cape Supalux
Board
Cape Building
Products Limited
(See remarks)
Fibre reinforced
calcium silicate
board.
Protection of
steel beams and
columns up to 2
hrs. FRP.
BS 476: Parts 20
& 21: 1987
N/A The Loss
Prevention
Council
CC82875 February 1993 February
1996
18/01/2005 No-objection letter
issued in 1993.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire protection material
should be in
accordance with Tables
9 to 18 in the report no.
CC82875.
BD-FP
006 Cape
Vermiculux
Board
Cape Building
Products Limited
(See remarks)
Vermiculux board Protection of
steel beams and
columns up to 4
hrs. FRP.
BS 476: Parts 20
& 21: 1987
N/A Building
Research
Establishment
The Loss
Prevention
Council
FRS.3/06/15
FCA/MEF
CC82017D
RHE/MB
March 1981
December
1991
December
1994
18/01/2005 No-objection letter
issued in 1992.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting board
shall be in accordance
with BRE’s assessment
letter ref.
FRS.3/06/15FCA/MEF
.
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
007
Cape
Vermiculux
Board
Cape Building
Products Limited
(See remarks)
Vermiculux board
fixed by expansion
bolts with or without
steel hat-sections.
Protection of
R.C. slabs up to
4 hrs. FRP.
As the system
does not form an
integral part of
the structure, the
actual
application and
acceptability of
the system
should be
considered on a
job-by-job basis.
BS 476: Parts 20
& 21: 1987
BS 8110: Part 1:
1985
N/A The Loss
Prevention
Council
CC10626/R
HE
November
1990
November
1992
18/01/2005 No-objection letter
issued in 1992.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
The fire protection
system shall be as
described in the report
no. CC10626/RHE.
BD-FP
008
Conlit 100 Rockwool Limited
(See remarks)
Resin bonded rock
fibre insulation
board
Protection of
steel beams and
columns up to 4
hrs. FRP.
BS 476: Parts 20
& 21: 1987
N/A The Loss
Prevention
Council
CC10806/R
HE,
CC81338A/
RHE
August 1989
May 1991 May 1993
18/01/2005 No-objection letter
issued in 1991.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting board
shall be in accordance
with the data indicated
in “Fire Protection for
Structural Steel in
Buildings (2nd
Edition)” published by
the Association of
Structural Fire
Protection Contractors
and Manufacturers Ltd.
(ASFPCM).
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
009
Conlit 150 &
150P
Rockwool Limited
(See remarks)
Mineral fibre
fire-resisting board
Protection of
steel beams and
columns up to 4
hrs. FRP.
BS 476: Parts 20
& 21: 1987
N/A The Loss
Prevention
Council
CC81338 May 1991 N/A 18/01/2005 No-objection letter
issued in 1993.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with
Figures 1 & 2 in the
report no. CC81338.
BD-FP
010
Cryosil Cryotherm
Insulation Limited
(See remarks)
Silicate bonded
vermiculite board
Protection of
steel beams and
columns up to 2
hrs. FRP.
BS 476: Parts 20
& 21: 1987
N/A The Loss
Prevention
Council
CC81951 December
1991
December
1994
18/01/2005 No-objection letter
issued in 1992.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with Figure
1 in the report no.
CC81951.
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
011
Durasteel Floor
(System)
Cape Durasteel
Limited
(See remarks)
Durasteel 3DF2
panels (9.5mm
thick) enclosing a
core of Rocksil
LR/AT 140 (overall
thickness 120mm).
Fire resisting
floor for up to 4
hrs. FRP in terms
of loadbearing
capacity,
integrity and
insulation.
Clear spans of
the two way
floor slab limited
to 4.17m x 3.5m.
Imposed load
limited to 5kPa
maximum.
Strength design
of the steelwork
is to be carried
out and
considered
separately by the
RSE.
BS 476: Parts 20
& 21: 1987
N/A The Loss
Prevention
Council
TE82867 December
1992
N/A 18/01/2005 No-objection letter
issued in 1993.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
The construction
details should be in
accordance with that
shown in the technical
evaluation TE82867.
BD-FP
012
Fendolite MII Mandoval
Coatings Limited
(See remarks)
Premix based on
vermiculite and
Portland cement.
Protection of
steel beams and
columns up to 4
hrs. FRP.
BS 476: Parts 20
& 21: 1987
N/A The Loss
Prevention
Council
CC82278A July 1992 July 1995 18/01/2005 No-objection letter
issued in 1993.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with Table
5 in the report no.
CC82278A.
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
013
Firetex
M70/M71
W & J Leigh &
Co.
(See remarks)
Intumescent Coating Protection of
steel I-beams up
to 11/2 hrs. FRP;
Protection of
SHS and CHS
steel columns up
to 1 hr. FRP;
Protection of
steel I-columns
and RHS steel
beams up to 2
hrs. FRP.
BS 476: Parts 20
& 21: 1987
N/A Warrington
Fire Research
Consultants
WFRC No.
C81691
WFRC No.
C80529
WFRC No.
C47373
March 1995
December
1992
June 1989
April 1997 18/01/2005 No-objection letter
issued in 1995.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with Tables
1 to 7 in the report
WFRC No. C47373.
Thickness quoted
refers to total dry film
thickness including the
primer and any top
sealer, where the
thickness of the primer
and any top sealer
together do not exceed
0.125mm.
BD-FP
014
Firetex M70
Intubuild
W & J Leigh &
Co.
(See remarks)
Intumescent Coating Protection of
steel columns up
to 1 hr. FRP.
BS 476: Parts 20
& 21: 1987
N/A The Loss
Prevention
Council
TE5944 November
1986
N/A 18/01/2005 No-objection letter
issued in 1990.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with the
test report no. TE5944.
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
015 Glulite Fire
Protection
Board
Cryotherm
Insulation Limited
(See remarks)
Resin-bonded
mineral fibre board.
BS 476: Parts 20
& 21: 1987
N/A The Loss
Prevention
Council
CC80705B/
RHE
October 1990 October
1992
18/01/2005 No-objection letter
issued in 1993.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with
Figures 1 & 2 in the
report no.
CC80705B/RHE.
Protection of
steel beams and
columns up to 4
hrs. FRP.
Panels are glued
with Rockbond
WR adhesive,
fastened to the
noggins with
Rockbond WR
adhesive and
wire nails.
BD-FP
016 Impact Fire
Board
Pilkington
Insulation Limited
(See remarks)
Fibre reinforced
cement board.
Protection of
steel beams and
columns up to 2
hrs. FRP.
Special
consideration is
required when
the web depth
exceeds 686mm
or flange width
exceeds 325mm.
BS 476: Parts 20
& 21: 1987
N/A Warrington
Fire Research
Consultants
WFRC No.
C44908
Re-Issue No.
1
October 1988 October
1990
18/01/2005 No-objection letter
issued in 1990.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Dry thickness of the
material should be in
accordance with Tables
4 & 4A in the report
WFRC No. C44908
(Re-Issue No. 1).
BD-FP
Reference List of Fire Protection Materials for Structural Use
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
017
Interbond
FP-HFA 900
International Paint
Limited
(See remarks)
Intumescent Coating Protection of
hollow steel
sections up to 1
hr. FRP.
Protection of
steel I sections
up to 11/2 hrs.
FRP.
BS 476: Parts 20
& 21: 1987
N/A Warrington
Fire Research
Consultants
Warrington
Fire Research
Consultants
WFRC No.
C44900
WFRC No.
C49685
August 1988
July 1990
August 1990
July 1992
18/01/2005 No-objection letter
issued in 1993.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with Table
2 in the reports WFRC
No. C44900 & WFRC
No. C49685.
BD-FP
018 Mandolite CP2 Mandoval
Coatings Limited
(See remarks)
Pre-mix based on
vermiculite and
Portland cement.
Protection of
steel beams and
columns up to 4
hrs. FRP.
BS 476: Parts 20
& 21: 1987
N/A Warrington
Fire Research
Consultants
WFRC No.
C52252
November
1990
N/A 18/01/2005 No-objection letter
issued in 1991.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with Tables
12 & 13 in the report
WFRC No. C52252.
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
019
Mandolite CP2 Mandoval
Coatings Limited
(See remarks)
Pre-mix based on
vermiculite and
Portland cement.
Upgrade
reinforced
concrete slabs up
to 4 hrs. FRP.
BS 476: Parts 20
& 21: 1987
BS 8110: Part 2:
1985
N/A Warrington
Fire Research
Centre
WFRC No.
CP92117
March 1992 April 1994 18/01/2005 No-objection letter
issued in 1992.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with Tables
1, 2 & 3 in the reports
WFRC No. CP92117.
Both structural stability
and insulation
requirements should be
considered and the
greater of the
thicknesses applied.
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
020
Mandolite CP2 Mandoval
Coatings Limited
(See remarks)
Pre-mix based on
vermiculite and
Portland cement.
Upgrade
reinforced
concrete beams,
columns and
walls up to 4 hrs.
FRP.
BS 476: Parts 20
& 21: 1987
BS 8110: Part 2:
1985
N/A Warrington
Fire Research
Centre
WFRC No.
C80520
WFRC No.
CP92117
December
1992
March 1992
January 1995
April 1994
18/01/2005 No-objection letter
issued in 1993.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with Table
2 in the report WFRC
No. CP92117.
The minimum sizes of
reinforced concrete
beams, columns and
walls should not be less
than those specified in
the Code of Practice
for Fire Resisting
Construction.
BD-FP
021
Monokote
MK5 & MK6
W.R. Grace & Co.
Construction
Products Division
(See remarks)
Sprayed-applied
cementitious
fire-proofing plaster.
Protection of
steel beams and
columns up to 4
hrs. FRP.
BS 476: Parts 20
& 21: 1987
N/A Warrington
Fire Research
Centre
C80173-AH
B/mj
May 1992 N/A 18/01/2005 No-objection letter
issued in 1992.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with data
sheet referred to in the
letter Ref.
C80173-AHB/mj.
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
022
Monokote
Zonolite Z-106
W.R. Grace & Co.
Construction
Products Division
(See remarks)
Sprayed-applied
cementitious fire
protection material.
Protection of
steel beams and
columns up to 4
hrs. FRP.
BS 476: Parts 20
& 21: 1987
N/A Ian Smith
(Consultancy)
Limited
CIS/ER/329/
B
November
1988
N/A 18/01/2005 No-objection letter
issued in 1992.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with Table
2 attached to Ian Smith
(Consultancy) Ltd’s
letter Ref.
CIS/ER/329/B.
BD-FP
023
New Promalit Eternit UK
Limited
(See remarks)
Lightweight
rockwool board.
Protection of
steel beams and
columns up to 3
hrs. FRP.
BS 476: Parts 20
& 21: 1987
N/A Building
Research
Establishment
FRO512/2
FT92/259/B
S
April 1993 N/A 18/01/2005 No-objection letter
issued in 1993.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with the
table in BRE’s letter
Ref. FRO512/2
FT92/259/BS.
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
024 Nullifire S602
& S603
Nullifire Limited
(See remarks)
Intumescent Coating Protection of
steel I-beams and
I-columns, RHS
and CHS
columns up to 1
hr. FRP.
Protection of
RHS beams up
to 11/2 hrs. FRP.
BS 476: Parts 20
& 21: 1987
N/A Certifire
Limited
CF103 May 1987 and
revised on
March 1990.
N/A 18/01/2005 No-objection letter
issued in 1990.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with Tables
3, 4 & 5 in the
certificate no. CF103.
Thickness quoted refer
to total dry film
thickness including the
primer and any top
sealer, where the
thickness of the primer
and any top sealer
together do not exceed
0.1mm.
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
025
Nullifire S605 Nullifire Limited
(See remarks)
Intumescent
Coating.
Protection of
steel I-beams and
I-columns up to
2 hrs. FRP.
Protection of
CHS columns up
to 1 hr. FRP.
BS 476: Parts 20
& 21: 1987
N/A Certifire
Limited
CF103 May 1987 and
revised on
March 1990.
N/A 18/01/2005 No-objection letter
issued in 1990.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with Tables
6, 7, 8 & 9 in the
certificate no. CF103.
Thickness quoted refer
to total dry film
thickness including the
primer and any top
sealer, where the
thickness of the primer
and any top sealer
together do not exceed
0.1mm.
BD-FP
026
Nullifire S607 Nullifire Limited
(See remarks)
Intumescent Coating Protection of
steel I-beams up
to 11/2 hrs. FRP.
Protection of
steel I-columns,
RHS and CHS
columns up to 1
hr. FRP.
BS 476: Parts 20
& 21: 1987
N/A Certifire
Limited
CF103 May 1987 and
revised on
October 1992.
N/A 18/01/2005 No-objection letter
issued in 1993.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with Tables
10, 11 & 12 in the
certificate no. CF103.
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
027
Nullifire Firec
F333
Nullifire Limited
(See remarks)
Intumescent
Coating.
Protection of
steel I-beams and
I-columns and
CHS up to 2 hrs.
FRP.
Protection of
solid circular tie
bars up to 3 hrs.
FRP.
BS 476: Parts 20
& 21: 1987
N/A Certifire
Limited
CF103 May 1987 and
revised on
March 1990.
N/A 18/01/2005 No-objection letter
issued in 1990.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with Tables
10 to 14 in the
certificate no. CF103.
Thickness quoted refer
to total dry film
thickness including the
primer and any top
sealer, where the
thickness of the primer
and any top sealer
together do not exceed
0.1mm.
BD-FP
028
Panelcrete
Impact Fire
Board
Panelcrete Limited
(See remarks)
Fibre reinforced
concrete board
Protection of
steel beams and
columns up to 2
hrs. FRP.
Application
limited to
I-section with
web depth not
exceeding
686mm and
flange width not
exceeding
325mm.
BS 476: Parts 20
& 21: 1987
N/A Warrington
Fire Research
Consultants
WFRC No.
C44908
Re-Issue No.
1
October 1988 October
1990
18/01/2005 No-objection letter
issued in 1994.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with Tables
4 & 4A in the report
WFRC No. C44908
(Re-Issue No. 1).
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
029
Promatect H Eternit UK
Limited,
Blackburn, UK.
or
Eternit N.V.
Kapelle-op-den-bo
s Belgium.
Fibre-reinforced
calcium silicate
insulating board.
Protection of
steel beams and
columns up to 2
hrs. FRP.
BS 476: Parts 20
& 21: 1987
N/A The Loss
Prevention
Council
CC82518/R
HE
June 1992 June 1995 18/01/2005 No-objection letter
issued in 1992.
Required thickness of
fire-resisting material
should be in
accordance with Figure
1 in the report no.
CC82518/RHE.
BD-FP
030
Promatect L Eternit UK
Limited,
Blackburn, UK.
or
Eternit N.V.
Kapelle-op-den-bo
s Belgium.
Fibre reinforced
calcium silicate
insulating board
Protection of
steel beams and
columns up to 4
hrs. FRP.
BS 476: Parts 20
& 21: 1987
N/A The Loss
Prevention
Council
CC82519/R
HE
June 1992 June 1995 18/01/2005 No-objection letter
issued in 1992.
Required thickness of
fire-resisting material
should be in
accordance with Figure
1 in the report no.
CC82519/RHE.
BD-FP
031
Pyrok CV25 Pyrok Building
Products Limited
(See remarks)
Cement-based fire
resisting plaster
aining
vermiculite.
cont
Protection of
steel beams and
columns up to 4
hrs. FRP.
BS 476: Parts 20
& 21: 1987
N/A Building
Research
Establishment
FRO512/-FT
91/409/BS
February 1992 N/A 18/01/2005 No-objection letter
issued in 1992.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with the
BRE’s letter Ref.
FRO512/-FT91/409/B
S.
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting
into CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
032
Pyrok CV27 Pyrok Building
Products Limited
(See remarks)
Cement-based fire
resisting plaster
containing
vermiculite.
Upgrade
reinforced
concrete slabs up
to 4 hrs. FRP.
BS 476: Parts 20
& 21: 1987
BS 8110: Part 2:
1985
N/A Warrington
Fire Research
Centre
WFRC No.
C80277
WFRC No.
41664
September
1992
June 1987
October
1994
18/01/2005 No-objection letter
issued in 1993.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with Tables
1, 2 & 3 in the report
WFRC 41664.
Both structural stability
and insulation
requirements should be
considered and the
greater of the
thicknesses applied.
BD-FP
033
Quelfire
Steelcote 60
Quelfire Limited
(See remarks)
Intumescent Coating Protection of
steel I- beams up
to 11/2 hrs. FRP.
Protection of
steel I-columns
and RHS beams
up to 2 hrs. FRP.
Protection of
RHS and CHS
columns up to 1
hr. FRP.
Protection of
circular hollow
and cruciform
cast iron
columns up to 1
hr. FRP.
BS 476: Parts 20
& 21: 1987
N/A Warrington
Fire Research
Consultants
WFRC No.
C51739
October 1990 October
1992
18/01/2005 No-objection letter
issued in 1993.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with Tables
1 to 6 in the report
WFRC No. C51739.
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
034
Rockcem Cryotherm
Insulation Limited
(See remarks)
Premix based on
rock-fibre and
Portland cement.
Protection of
steel beams and
columns up to 4
hrs. FRP.
BS 476: Parts 20
& 21: 1987
N/A Building
Research
Establishment
A22/3349
FCA/IC
June 1984 N/A 18/01/2005 No-objection letter
issued in 1993.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with the
BRE’s letter Ref.
A22/3349 FCA/IC.
BD-FP
035
Spiralite Fire
Protection
Board
Cryotherm
Insulation Limited
(See remarks)
Resin-bonded
mineral fibre board.
Protection of
steel beams and
columns up to 2
hrs. FRP.
Panels are
fastened to the
noggins with
Spiralite coil
screws.
BS 476: Parts 20
& 21: 1987
N/A The Loss
Prevention
Council
CC10786/81
887A
RHE/MB
July 1989 and
reviewed in
November
1991
November
1993
18/01/2005 No-objection letter
issued in 1993.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with Table
1 in the report no.
CC10786/81887A
RHE/MB.
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
036
Spraydon F. G. Thermoduric
Limited
(See remarks)
Spray applied
mineral wool.
Protection of
structural
steelwork up to 4
hrs. FRP.
BS 476: Parts 20
& 21: 1987
N/A Warrington
Fire Research
Centre
Warrington
Fire Research
Consultants
WFRC No.
C80980
WFRC No.
C43587
November
1993
March 1988
November
1995
18/01/2005 No-objection letter
issued in 1993.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with
Summary Table 1 in
the report WFRC No.
C43587.
BD-FP
037
Sprayed
Limpet
Mineral Wool
Pilkington
Insulation Limited
(See remarks)
Sprayed mineral
wool
Protection of
structural
steelwork up to 4
hrs. FRP.
BS 476: Parts 20
& 21: 1987
N/A N/A N/A*
* Test or
assessment
report could
not be
retrieved.
N/A N/A 18/01/2005 No-objection letter
issued in 1994.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with the
data indicated on page
73 of “Fire Protection
for Structural Steel in
Buildings (2nd
Edition)” published by
the Association of
Structural Fire
Protection Contractors
and Manufacturers Ltd.
(ASFPCM).
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
038
Sprayed
Limpet
Vermiculite
Pilkington
Insulation Limited
(See remarks)
Sprayed vermiculite
cement
Protection of
structural
steelwork up to 4
hrs. FRP.
BS 476: Parts 20
& 21: 1987
N/A N/A N/A*
* Test or
assessment
report could
not be
retrieved.
N/A N/A 18/01/2005 No-objection letter
issued in 1994.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with the
data indicated on pages
75 & 77 of “Fire
Protection for
Structural Steel in
Buildings (2nd
Edition)” published by
the Association of
Structural Fire
Protection Contractors
and Manufacturers Ltd.
(ASFPCM).
BD-FP
039
Steelguard FM Mebon Limited
(See remarks)
Intumescent Coating Protection of
steel I- beams,
I-columns and
RHS beams up
to 11/2 hrs. FRP.
Protection of
RHS columns up
to 1 hr. FRP.
BS 476: Parts 20
& 21: 1987
N/A The Loss
Prevention
Council
CC80320
CC81382
December
1990
December
1992
18/01/2005 No-objection letter
issued in 1992.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with Tables
5 & 6 in the report no.
CC80320, Table 2 in
the report no.
CC81382.
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
040
Steelmaster Mebon Limited
(See remarks)
Intumescent Coating Protection of
steel I-beams,
I-columns and
RHS beams up
to 11/2 hrs. FRP.
Protection of
RHS and CHS
columns up to 1
hr. FRP.
BS 476: Parts 20
& 21: 1987
N/A The Loss
Prevention
Council
CC81987
CC81987A
December
1991
December
1993
18/01/2005 No-objection letter
issued in 1992.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with Tables
5 & 6 in the report no.
CC81987, Table 2 in
the report no.
CC81987A.
BD-FP
041
TD Board Thermoduric
Limited
(See remarks)
Mineral Wool Protection of
steel beams and
columns up to 4
hrs. FRP.
BS 476: Parts 20
& 21: 1987
N/A The Loss
Prevention
Council
CC83128 December
1992
18/01/2005 No-objection letter
issued in 1993.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with
Figures 1 & 2 in the
report no. CC83128.
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
042
Unitherm
38091
Herberts GmbH.
(See remarks)
Intumescent Coating Protection of
steel I-beams and
I-columns up to
2 hrs. FRP.
BS 476: Parts 20
& 21: 1987
N/A Warrington
Fire Research
Centre
WFRC No.
C81065
March 1994 April 1996 18/01/2005 No-objection letter
issued in 1994.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with Table
1 in the report WFRC
No. C81065.
BD-FP
043
Unitherm A60 Herberts GmbH.
(See remarks)
Intumescent Coating Protection of
steel I-beams and
I-columns up to
1 hr. FRP.
BS 476: Parts 20
& 21: 1987
N/A Warrington
Fire Research
Consultants
WFRC No.
C44347
May 1988 18/01/2005 No-objection letter
issued in 1991.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with Figure
3 in the report no.
CC44347.
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
044
Unitherm Fire
Protection
Coating
Dispersal,
Water Soluble
Herberts GmbH.
(See remarks)
Intumescent Coating Protection of
internal steel
I-beams up to
11/2 hrs. FRP.
Protection of
internal steel
I-columns up to
1 hr. FRP.
BS 476: Parts 20
& 21: 1987
N/A Warrington
Fire Research
Centre
WFRC No.
C80058
March 1992 April 1994 18/01/2005 No-objection letter
issued in 1992.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with Table
1 in the report WFRC
No. C80058.
BD-FP
045
Vicuclad Eternit UK
Limited,
Blackburn, UK.
or
Eternit N.V.
Kapelle-op-den-bo
s Belgium
Insulation boards
produced from
mixing vermiculite
with inorganic
binders.
Protection of
steel beams and
columns up to 2
hrs. FRP in
screw-fix
Vicuclad system.
Protection of
steel beams and
columns up to 4
hrs. FRP in
bonded Vicuclad
system.
BS 476: Parts 20
& 21: 1987
N/A The Loss
Prevention
Council
CC82520/R
HE
June 1992 June 1995 18/01/2005 No-objection letter
issued in 1992.
Required thickness of
fire-resisting material
should be in
accordance with Figure
1 in the report no.
CC82520/RHE.
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
046
Zonolite W.R. Grace & Co.
(See remarks)
Cementitious
fibre-reinforced
material.
Protection of
steel beams and
columns up to 4
hrs. FRP.
BS 476: Parts 20
& 21: 1987
N/A Ian Smith
(Consultancy)
Limited.
CIS/ER/329/
B
November
1988
N/A 18/01/2005 No-objection letter
issued in 1989.
Updated information
on place of
manufacture to be
provided by the
manufacturer.
Required thickness of
fire-resisting material
should be in
accordance with Table
2 in Ian Smith
(Consultancy) Ltd’s
letter ref.
CIS/ER/329/B.
BD-FP
047
Firecut
FM-900
Yung Chi Paint &
Varnish Mfg Co
Ltd.
Koahsiung,
Taiwan
Single pack solvent
based intumescent
coating
Protection of
steel I-beams and
I-columns up to
1 hr. FRP.
BS 476: Parts 20
& 21: 1987
UKAS Warrington
Fire Research
Centre
WFRC No.
C123992
WFRC No.
C110854
8 April 2002
1 November
1999
valid until 1
April 2007
lapse on 1
December
2001
28/04/2005
BD-FP
048
Firecut
FM-900
Yung Chi Paint &
Varnish Mfg Co
Ltd.
Koahsiung,
Taiwan
Single pack solvent
based intumescent
coating
Protection of
steel I-beams and
I-columns up to
2 hrs. FRP.
BS 476: Parts 20
& 21: 1987
UKAS Warrington
Fire Research
Centre
WFRC No.
C125252
19 June 2002 valid until 1
July 2007
28/04/2005
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
049
Firecut
FM-900
Yung Chi Paint &
Varnish Mfg Co
Ltd.
Koahsiung,
Taiwan
Single pack solvent
based intumescent
coating
Protection of
4-side exposed
RHS and CHS
up to 2 hrs. FRP.
BS 476: Parts 20
& 21: 1987
UKAS Warrington
Fire Research
Centre
WFRC No.
C125331
19 June 2002 valid until 1
July 2007
28/04/2005
BD-FP
050
Firecut
FM-900
Yung Chi Paint &
Varnish Mfg Co
Ltd.
Koahsiung,
Taiwan
Single pack solvent
based intumescent
coating
Protection of
3-side exposed
RHS up to 2 hrs.
FRP.
BS 476: Parts 20
& 21: 1987
UKAS Warrington
Fire Research
Centre
WFRC No.
C126749
WFRC No.
C115007
27 August
2002
31 July 2000
valid until 1
September
2007
valid until 1
August 2002
28/04/2005
BD-FP
051
Vermitex AF L&A Fazzini
Manufacturing Pty
Ltd.
Greenacre NSW,
Australia
Gypsum-vermiculite
coating
Protection of
steel I-sections
up to 2 hrs. FRP.
AS 1530.4 and
BS 476: Part 21
NATA CSIRO FCO-1299
(Revision)
FCO-0812
(Revision)
22 October
2003
9 November
2001
lapse on 31
July 2007
lapse on 1
March 2005
28/04/2005 According to the
manufacturer’s
recommendation,
Vermitex AF is for
internal application.
CSIRO opinion no.
FCO-0812 (Revision)
assessed compatibility
of Vermitex spray
protection system with
certain types of primer.
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
052
Vermitex DX L&A Fazzini
Manufacturing Pty
Ltd.
Greenacre NSW,
Australia
Cement-vermiculite
coating
Protection of
steel I-sections
up to 2 hrs. FRP.
AS 1530.4 and
BS 476: Part 21
NATA CSIRO FCO-1299
(Revision)
FCO-0812
(Revision)
22 October
2003
9 November
2001
lapse on 31
July 2007
lapse on 1
March 2005
28/04/2005 According to the
manufacturer’s
recommendation,
Vermitex DX is for
external application.
CSIRO opinion no.
FCO-0812 (Revision)
assessed compatibility
of Vermitex spray
protection system with
certain types of primer.
BD-FP
053
Cafco 300 Isolatek
International
New Jersey, USA
Single package
factory controlled
premix based on
vermiculite and
gypsum
Protection of
3-side exposed
UB and UC
sections up to 4
hrs. FRP.
BS 476: Parts 20
& 21: 1987
Recognized by
PNAP 251
Building
Research
Establishment
CC 206998 17 April 2002 next review
date: 4
March 2007
28/04/2005
BD-FP
054
Hilti HIT-HY
150
Hilti Corporation
Kaufering,
Gemany
Hybrid resin system Injection system
for making
nominal
anchorage
connections of
Grade 460 rebars
of diameters up
to 25mm in
reinforced
concrete
elements up to 4
hrs. FRP.
BS 476: Part 20:
1987
UKAS Warrington
Fire Research
Centre
WFRC No.
C121086
25 September
2002
valid until 1
October
2007
28/04/2005 Load carrying capacity
of the injection system
for rebar fixing under
the effects of fire
should be assessed
with an appropriate
factor of safety
compatible with the
structural design of the
parent structure.
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
055
Hilti HIT-RE
500
Hilti Corporation
Kaufering,
Gemany
Epoxy resin system Injection system
for making
nominal
anchorage
connections of
Grade 460 rebars
of diameters up
to 40mm in
reinforced
concrete
elements up to 4
hrs. FRP.
BS 476: Part 20:
1987
UKAS Warrington
Fire Research
Centre
WFRC No.
C121086
25 September
2002
valid until 1
October
2007
28/04/2005 Load carrying capacity
of the injection system
for rebar fixing under
the effects of fire
should be assessed
with an appropriate
factor of safety
compatible with the
structural design of the
parent structure.
BD-FP
056
Durasteel
board
Intumex Asia
Pacific Pte. Ltd.
Blackburn, UK
9.5mm thick
Durasteel board
Fire resisting
steel platform
floors covered
with two layers
of Durasteel
(constructions
are given in the
assessment
reports) when
exposed to fire
for 1 hr. FRP in
terms of
loadbearing
capacity,
integrity and
insulation.
Maximum
imposed load to
be 7.5kPa..
BS 476: Parts 20
& 21: 1987
UKAS Warrington
Fire Research
Centre
WFRC
Assessment
Report No.
138676
19 May 2004 valid until 1
June 2009
03/08/2005 The construction
details should be
identical to those
covered in the
assessment reports.
All requirements given
in the assessment
reports should be
checked to ensure
compatibility with
proposed applications.
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
057
Unitherm
38091
Dupont
Performance
Coatings GmbH &
Co.
Stuttgart, Gemany
Intumescent coating Protection of
RHS and CHS
beams and
columns up to 1
hr. FRP.
BS 476: Parts 20
& 21: 1987
UKAS Warrington
Fire Research
Centre
WFRC
Assessment
Report No.
C126392
Issue 3
WFRC No.
C105708
WFRC No.
C125342
Issue 2
WFRC
Assessment
Report No.
140896
22 July 2004
8 February
1999
13 August
2002
14 July 2004
N/A
See WFRC
Assessment
Report No.
C126392
Issue 3
valid until 1
September
2007
valid until 1
August 2009
03/08/2005
BD-FP
058
Cafco 300 Isolatek
International
New Jersey, USA
Single package
factory controlled
premix based on
vermiculite and
gypsum
Protection of
steel I-columns,
RHS and CHS
beams and
columns up to 2
hrs. FRP.
BS 476: Parts 20
& 21: 1987
Recognized by
PNAP 251
Building
Research
Establishment
CC 206998 17 April 2002 next review
date: 4
March 2007
03/08/2005 Section 1.6.2 of Fire
Protection for
Structural Steel in
Buildings published by
the Association for
Specialist Fire
Protection contains
recommendations for
determination of spray
thickness for hollow
sections based on
technical data for steel
I-sections.
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
059
Cafco
SprayFilm
WB3
Cafco International
UK
Guangzhou, China
Intumescent coating Protection of
steel I-beams,
I-columns, RHS
and CHS beams
and columns up
to 2 hrs. FRP.
BS 476: Parts 20
& 21: 1987
UKAS Warrington
Fire Research
Centre
WFRC
Assessment
Report No.
C139823
WFRC
Assessment
Report No.
139822
27 May 2004
16 June 2004
valid until 1
June 2009
valid until 1
July 2009
03/08/2005
BD-FP
060
Firetherm
Firesteel
Classic
Firetherm
Intumescent &
Insulation Supplies
Ltd.
Dartford, UK
Solvent based
intumescent coating
Protection of
steel I-beams and
I-columns up to
1 hr. FRP.
BS 476: Parts 20
& 21: 1987
UKAS Warrington
Fire Research
Centre
WFRC No.
123080
WFRC No.
100784
28 January
2001
22 October
1997
valid until 1
February
2007
see WFRC
No. 123080
03/08/2005
BD-FP
061
Nullifire S606 Nullifire Limited
Coventry, UK
Intumescent coating Protection of
4-side exposed I
sections, RHS
and CHS
columns up to 2
hrs. FRP.
BS 476: Parts 20
& 21: 1987
Recognized by
PNAP 251
Building
Research
Establishment
CC 92856A
CC 92856B
10 April 2003
10 April 2003
next review
date: 10
April 2008
next review
date: 10
April 2008
03/08/2005
BD-FP
062
Nullifire S605 Nullifire Limited
Coventry, UK
Intumescent coating Protection of
4-side exposed
RHS up to 1 hr.
FRP.
BS 476: Parts 20
& 21: 1987
Recognized by
PNAP 251
Building
Research
Establishment
CC 93058B
Review 2
21 July 2003 next review
date: 21 July
2008
26/10/2005
BD-FP
063
Interchar 963 International Paint
Limited
Shanghai, China
Intumescent coating Protection of
3-side exposed
steel channels
and angles up to
1 hr. FRP.
BS 476: Parts 20
& 21: 1987
UKAS Warrington
Fire Research
Centre
WFRC
Assessment
Report No.
136405
15 January
2004
valid until 1
February
2009
03/02/2006
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
064
Phoenix 167 Phoenix Fire
Protection (Asia)
Ltd.
Mannheim,
Germany
Intumescent coating Protection of
4-side exposed
hollow columns
up to 1 hr. FRP.
BS 476: Parts 20
& 21: 1987
UKAS Warrington
Fire Research
Centre
WFRC
Assessment
Report No.
143912
20 December
2004
valid until 1
January 2010
03/02/2006
BD-FP
065
Phoenix 168 Phoenix Fire
Protection (Asia)
Ltd.
Mannheim,
Germany
Intumescent coating Protection of
3-side and 4-side
exposed I beam
sections up to 1
hr. FRP.
BS 476: Parts 20
& 21: 1987
UKAS Warrington
Fire Research
Centre
WFRC No.
C126964
WFRC No.
C126965
30 September
2002
30 September
2002
valid until 1
October
2007
valid until 1
October
2007
03/02/2006
BD-FP
066
Cafco 280 Cafco International
Indiana, USA
Cementitious
mineral fibre
Protection of
steel beams and
columns up to 4
hrs. FRP.
BS 476: Parts 20
& 21: 1987
Recognized by
PNAP 251
Building
Research
Establishment
CC 376.3 17 March
2003
next review
date: 17
March 2008
21/04/2006
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
067
Durasteel Floor
Assemblies
Intumex Asia
Pacific Pte. Ltd.
Blackburn, UK
Single layer of
9.5mm thick
Durasteel board,
fastened above and
below a framework
of steel channels,
enclosing a cavity
containing 140kg/m3
density rock wool
with a minimum
overall thickness of
80mm.
Fire resisting
floor assemblies
(construction
details are given
in the assessment
reports) for up to
2 hrs. FRP in
terms of
loadbearing
capacity,
integrity and
insulation.
Maximum
imposed load to
be 10kPa.
Primary
members of the
steel framework
are located
parallel with and
on top of main
structural
supporting
beams at 1m,
1.2m or 2.4m
centers as given
in the assessment
reports. Cross
members are
spaced at
600mm max.
centers.
BS 476: Parts 20
& 21: 1987
Recognized by
PNAP 251
UKAS
Building
Research
Establishment
Warrington
Fire Research
Centre
CC 94333
WFRC
Assessment
report No.
136396
22 March
2002
22 March
2004
next review
date: 22
March 2007
valid until 1
April 2009
21/07/2006 The construction
details should be
identical to those
covered in the
assessment reports.
All requirements given
in the assessment
reports should be
checked to ensure
compatibility with
proposed applications.
The assembly shall be
supported by structural
steel beams that are
fitted with a
proprietary fire
protection system of
suitable thickness for
the relevant fire
resistance period and
for the section factor of
the beams.
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
068
Durasteel Floor
Assembly
Intumex Asia
Pacific Pte. Ltd.
Blackburn, UK
Two layers of 9.5mm
thick Durasteel
board, fastened to
the top of a steel
framework.
Fire resisting
floor assembly
(construction
details are given
in the assessment
report) for up to
1 hr. FRP (fire
attack from
either above or
below) in terms
of loadbearing
capacity,
integrity and
insulation.
Maximum
imposed load to
be 10kPa.
The steel
framework
consists of
primary
supporting
members at
maximum
2400mm centers
welded to
secondary
supporting
members at
maximum
600mm centers.
BS 476: Parts 20
& 21: 1987
UKAS Warringtonfire WF
Assessment
Report No.
148104
12 September
2005
valid until 1
October
2010
21/07/2006 The construction
details should be
identical to those
covered in the
assessment report.
All requirements given
in the assessment
report should be
checked to ensure
compatibility with
proposed application.
The steel framework of
the floor shall be
designed to be able to
bear the specified
uniformly distributed
imposed load of up to a
maximum of 10kPa.
When it is required to
withstand fire attack
from below, the steel
framework shall be
cladded with a
proprietary fire
protection system of
suitable thickness for
the relevant fire
resistance period at the
designed critical steel
temperature and for the
section factors of the
members.
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
069
Phoenix 270 Phoenix Fire
Protection (Asia)
Ltd.
Mannheim,
Germany
Intumescent coating Protection of
4-side exposed I-
sections up to 2
hrs. FRP.
BS 476: Parts 20
& 21: 1987
Recognized by
PNAP 251
International
Fire
Consultants
Ltd.
Field of
Application
Report
IFCA/05199
July 2005 valid until
July 2010
20/10/2006 A critical temperature
of 550℃ has been
assumed for 4-side
exposed steel sections.
BD-FP
070
Mandolite CP2 Cafco International
Alfreton,
Derbyshire, UK
Pre-mix based on
vermiculite and
Portland cement.
Upgrade
reinforced
concrete slabs,
beams, columns
and walls up to 4
hrs. FRP.
BS 476: Parts 20
& 21: 1987
BS 8110: Part 2:
1985
UKAS Warrington
Fire Research
Centre
WFRC No.
C132081C
WFRC No.
C80520
Issue No. 2
WFRC No.
C132081A
WFRC No.
CP92117
Rev.1
19 May 2003
19 January
1993
19 May 2003
5 March 1992
valid until 1
June 2008
valid until 1
February
1995
valid until 1
June 2008
valid until 1
April 1994
20/10/2006 For use on reinforced
concrete beams,
columns and walls, the
minimum size
requirements specified
in the Code of Practice
for Fire Resisting
Construction 1996 and
the criterion of stability
should be satisfied.
For use on reinforced
concrete slabs, the
criteria of stability and
insulation should be
satisfied.
BD-FP
071
Nullifire
System E
Carboline
USA
Intumescent coating Protection of
4-side exposed
CHS up to 1 hr.
FRP.
BS 476: Parts 20
& 21: 1987
UKAS Warrington
Fire Research
Centre
WFRC No.
C124329A
WFRC No.
C100578
19 April 2002
30 September
1997
valid until 1
May 2007
valid until 1
November
1999
20/10/2006 A critical temperature
of 550℃ has been
assumed for 4-side
exposed steel sections.
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
072
Phoenix 270 Phoenix Fire
Protection (Asia)
Ltd.
Mannheim,
Germany
Intumescent coating BS 476: Parts 20
& 21: 1987
Recognized by
PNAP 251
International
Fire
Consultants
Ltd.
Field of
Application
Report
IFCA/05196
July 2005 valid until
July 2010
22/01/2007 Protection of
4-side exposed
hollow sections
up to 2 hrs. FRP.
BD-FP
073
Unitherm
38091
Dupont
Performance
Coatings GmbH &
Co.
Stuttgart, Gemany
Intumescent coating Protection of
steel I-beams and
I-columns up to
2 hrs. FRP.
BS 476: Parts 20
& 21: 1987
UKAS Warrington
Fire Research
Centre
Assessment
Summary
WFRC No.
133394
WFRC No.
133000
WFRC No.
C125126
WFRC No.
C128560
WFRC No.
C105561
Issue 2
10 July 2003
20 June 2003
3 July 2002
27 November
2002
8 February
1999
N/A
valid until
1 July 2008
valid until
1 August
2007
valid until
1 December
2007
valid until
1 March
2001
22/01/2007
Reference List of Fire Protection Materials for Structural Use
BD-FP
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
074
Renitherm
PMA 1200
Audax-Keck
GmbH
Weiherstrasse,
Germany
Intumescent coating Protection of
3-side and 4-side
exposed
I sections up to 2
hrs. FRP.
BS 476: Parts 20
& 21: 1987
UKAS Warringtonfire WF
Assessment
Report No.
156366
12 July 2006 valid until
1 August
2011
22/01/2007
BD-FP
075
Pyrok CV27 Axiom
Engineering Ltd.
Hong Kong
Cement-based fire
resisting plaster
containing
vermiculite.
Upgrade
reinforced
concrete slabs up
to 4 hrs. FRP.
BS 476: Parts 20
& 21: 1987
BS 8110: Part 2:
1985
UKAS Warrington
Fire Research
Centre
WFRC No.
C139153
WFRC No.
41664
21 April 2004
June 1987
valid until
1 May 2009
22/01/2007 Required thickness of
fire-resisting material
should be in
accordance with Tables
1, 2 & 3 in the report
WFRC 41664.
Both structural stability
and insulation
requirements should be
considered and the
greater of the
thicknesses applied.
BD-FP
076
Firetherm
Firesteel
Classic 120
Firetherm
Intumescent &
Insulation Supplies
Ltd.
Kent, UK
Solvent based
intumescent coating
Protection of
3-side exposed
steel channel
sections /
I-section up to 2
hrs. FRP.
BS 476: Parts 20
& 21: 1987
UKAS Warrington
Fire Research
Centre
WFRC No.
C130413
6 March 2003 valid until 1
April 2008
3/8/2007 Assessment applicable
to steel I-section up to
a maximum web size
of 686mm and flange
size of 305mm
BD-FP
Reference List of Fire Protection Materials for Structural Use
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
077
Hilti HIT-RE
500
Hilti Corporation
Kaufering,
Gemany
Epoxy resin system Injection system
for making
nominal
anchorage
connections of
Grade 460 rebars
of diameters up
to 40mm in
reinforced
concrete
elements up to 2
hrs. FRP.
BS 476: Part 20:
1987
UKAS Bodycote
Warringtonfire
WF 166402 26 October
2007
valid until
1 November
2012
21.1.2008 Load carrying capacity
of the injection system
for rebar fixing under
the effects of fire
should be assessed
with an appropriate
factor of safety
compatible with the
structural design of the
parent structure.
BD-FP
078
Firetherm
Firesteel
Classic 120
Firetherm
Intumescent &
Insulation Supplies
Ltd.
Kent, UK
Solvent based
intumescent coating
Protection of
3-sides/ 4-sides
exposed steel
hollow beam
sections up to 2
hrs. FRP.
BS 476: Parts 20
& 21: 1987
UKAS Warrington
Fire Research
Centre
WFRC No.
C130414
6 March 2003 valid until
1 April 2008
21.1.2008
BD-FP
079
Nullifire S605 Nullifire Limited
Coventry, UK
Solvent based
intumescent coating
Protection of
Built up Box
Sections up to 2
hrs FRP and
SHS up to 1 hr.
FRP (4-side
exposed for both
sections)
BS 476: Parts 20
& 21: 1987
HOKLAS Research
Engineering
Development
Façade
Consultants
Limited
R07K15 24 October
2007
Valid until
21 July 2008
21/1/2008 The relationship
between protection
thickness, section
factor, and fire
resistance of structural
steel shall refer to BRE
assessment report
number CC 93058B.
The assessment of the
built up box section
under the fire test
report R07K15 was
based on fire test of a
rolled hollow section.
Reference List of Fire Protection Materials for Structural Use
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
080
Nullifire S606 Nullifire Limited
Coventry, UK
Solvent based
intumescent coating
Protection of
SHS beam
sections with
3-side exposed
and maximum
span of 1.3m for
2 hrs FRP
BS 476: Parts 20
& 21: 1987
HOKLAS Research
Engineering
Development
Façade
Consultants
Limited
R07L03 9 November
2007
Valid until
8 November
2009
21/1/2008 The relationship
between protection
thickness, section
factor, and fire
resistance of structural
steel shall refer to BRE
assessment report
number CC92856B.
Reference List of Fire Protection Materials for Structural Use
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
081
Durasteel Floor
Assemblies
Intumex Asia
Pacific Pte. Ltd.
Blackburn, UK
Single layer of
9.5mm thick
Durasteel board,
fastened above and
below a framework
of steel channels,
enclosing a cavity
containing 140kg/m3
density rock wool
with a minimum
overall thickness of
120mm.
Fire resisting floor
assemblies
(construction details
are given in the
assessment reports)
for up to 4 hrs. FRP
in terms of
load-bearing
capacity, integrity
and insulation.
Maximum imposed
load to be 5.0kPa.
Primary members of
the steel framework
are located parallel
with and on top of
main structural
supporting beams at
1m, 1.2m or 2.4m
centers as given in
the assessment
reports. Cross
members are spaced
at 600mm c/c.
Additional 2 nos. of
cover strips shall be
required for the top
and bottom flange of
the channel sections
for insulation use.
BS 476:
Parts 20 &
21: 1987
UKAS Warrington
Fire Research
Centre
WFRC
Assessment
report No.
136396
22 March
2004
valid until 1
April 2009
25/4/2008 The construction
details should be
identical to those
covered in the
assessment reports.
All requirements given
in the assessment
reports should be
checked to ensure
compatibility with
proposed applications.
The assembly shall be
supported by structural
steel beams that are
fitted with a
proprietary fire
protection system of
suitable thickness for
the relevant fire
resistance period and
for the section factor of
the beams.
Maximum load ratio of
structural steel
elements inside the
assembly shall be less
than or equal to 0.5
to BS5950: Part 1
Fire stop/ sealant shall
be provided for the
interface between the
perimeter of the
Durasteel floor and the
surrounding structures
Reference List of Fire Protection Materials for Structural Use
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
082
Durasteel
Protected Steel
Stair
Intumex Asia
Pacific Pte. Ltd.
Blackburn, UK
Single layer of
9.5mm thick
Durasteel board,
fastened above and
below a framework
of steel angles and
cold formed steel
sheet, enclosing a
cavity containing
140kg/m3 density
rock wool with a
minimum overall
thickness of 120mm.
Protected stairs
(construction details
are given in the
assessment reports)
for up to 4 hrs. FRP
in terms of
loadbearing capacity,
integrity and
insulation.
Maximum imposed
load to be 5.0kPa.
Cold formed steel
sheet supported by
steel angles create
the treads and risers
of the stair assembly
as well as supporting
the Durasteel board
on top. Back-to-back
steel angle spaced at
1.2m c/c hanging the
Durasteel board at
the underside of the
stairs. The main
structural beam
(I-section or hollow
section) along the
staircase is enclosed
inside the assembly
BS 476:
Parts 20 &
21: 1987
UKAS Warrington
Fire Research
Centre
WFRC
Assessment
report No.
141176
31 August
2004
valid until 1
September
2009
25/4/2008 The construction
details should be
identical to those
covered in the
assessment reports.
All requirements given
in the assessment
reports should be
checked to ensure
compatibility with
proposed applications.
Maximum load ratio of
structural steel
elements inside the
assembly shall be less
than or equal to 0.5
to BS5950: Part 1
Either full thickness or
at least half the
required thickness of
rock wool shall be
fitted between the
Durasteel and the main
structural steel
members supporting
the stair.
Fire stop/ sealant shall
be provided for the
interface between the
perimeter of the
Durasteel floor and the
surrounding structures
Reference List of Fire Protection Materials for Structural Use
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
083
Firecut
FM-900
Yung Chi Paint &
Varnish Mfg Co
Ltd.
Koahsiung,
Taiwan
Single pack solvent
based intumescent
coating
Protection of steel
I-beams and
I-columns up to 2
hrs. FRP.
BS 476:
Parts 20 &
21: 1987
UKAS Bodycote
Warringtonfire
WF No.
164158
20 August
2007
valid until1
June 2012
22/7/2008 This is resulted from
the expiry pf
BD-FP048
It should be read in
conjunction with fire
assessment report
WFRC No. 125252
BD-FP
084
Firecut
FM-900
Yung Chi Paint &
Varnish Mfg Co
Ltd.
Koahsiung,
Taiwan
Single pack solvent
based intumescent
coating
Protection of steel
angle, channel and
T-section to 2 hrs.
FRP.
BS 476:
Parts 20 &
21: 1987
UKAS Bodycote
Warringtonfire
WF No.
164158
20 August
2007
valid until1
June 2012
22/7/2008 It should be read in
conjunction with
Bodycote
Warringtonfire
assessment letter dated
22.10.2007regarding
sections with re-entrant
details.
BD-FP
085
Firecut
FM-900
Yung Chi Paint &
Varnish Mfg Co
Ltd.
Koahsiung,
Taiwan
Single pack solvent
based intumescent
coating
Protection of 4-side
exposed RHS and
CHS up to 2 hrs.
FRP.
BS 476:
Parts 20 &
21: 1987
UKAS Bodycote
Warringtonfire
WF No.
164159
20 August
2007
valid until 1
June 2012
22/7/2008 This is resulted from
the expiry of
BD-FP049
It should be read in
conjunction with fire
assessment report
WFRC No. 125331
BD-FP
086
Firecut
FM-900
Yung Chi Paint &
Varnish Mfg Co
Ltd.
Koahsiung,
Taiwan
Single pack solvent
based intumescent
coating
Protection of 3-side
exposed RHS up to
2 hrs. FRP.
BS 476:
Parts 20 &
21: 1987
UKAS Bodycote
Warringtonfire
WF No.
164160
20 August
2007
valid until 1
June 2012
22/7/2008 This is resulted from
the expiry of
BD-FP050
It should be read in
conjunction with fire
assessment report
WFRC No. 115007
BD-FP
087
Southwest A/D
Type 5GP
A/D Fire
Protection Systems
Toronto, Canada
Single component,
factory blended
cementitious spray
applied coating
Protection of beam
or column of
I-section and hollow
section up to 4 hrs
FRP.
BS 476:
Parts 20 &
21: 1987
UKAS Bodycote
Warringtonfire
WF No.
163280
WF No.
160007
WF No.
160008
20 June 2007
N/A
N/A
Valid until 1
July 2012
22/7/2008 A/D Type 5GP is not
intended for direct
exposure to weather or
excessive physical
abuse.
Reference List of Fire Protection Materials for Structural Use
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
088
Durasteel Floor
Assemblies
Intumex Asia
Pacific Pte. Ltd.
Blackburn, UK
Single layer of
9.5mm thick
Durasteel board,
fastened above and
below a framework
of steel channels,
enclosing a cavity
containing 140kg/m3
density rock wool
with a minimum
overall thickness of
80mm.
Fire resisting floor
assemblies
(construction details
are given in the
assessment reports)
for up to2 hrs. FRP
in terms of
load-bearing
capacity, integrity
and insulation.
Maximum imposed
load to be 10kPa.
Any point load shall
be distributed over
an area of
300mmx300mm.
Primary members of
the steel framework
are located parallel
with and on top of
main structural
supporting beams at
1m centers as given
in the assessment
reports. Cross
members are spaced
at 600mm c/c.
BS 476:
Parts 20 &
21: 1987
Recognized by
PNAP 251
Building
Research
Establishment
CC 94333
Review 2
20 July 2007 valid until
20 July 2012
22/7/2008 The construction
details should be
identical to those
covered in the
assessment reports.
All requirements given
in the assessment
reports should be
checked to ensure
compatibility with
proposed applications.
The assembly shall be
supported by structural
steel beams that are
fitted with a
proprietary fire
protection system of
suitable thickness for
the relevant fire
resistance period and
for the section factor of
the beams.
Maximum load ratio of
supporting steel
elements shall not
exceed 0.53 to
BS5950: Part 1
Fire stop/ sealant shall
be provided for the
interface between the
perimeter of the
Durasteel floor and the
surrounding structures
Reference List of Fire Protection Materials for Structural Use
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
089
Phoenix 168 Phoenix Fire
Protection (Asia)
Ltd.
Mannheim,
Germany
Intumescent coating
(water based)
Protection of 3-side
and 4-side exposed I
beam sections up to
1 hr. FRP.
BS 476:
Parts 20 &
21: 1987
UKAS Bodycote
Warringtonfire
WF No.
160031
WF No.
160032
1 December
2006
1 December
2006
valid until 1
December
2011
22/7/2008 This is resulted from
the expiry of BD-FP
065
It should be read in
conjunction with fire
assessment report
WFRC No. C126964
and C126965
BD-FP
090
Phoenix
270-120
Phoenix Fire
Protection (Asia)
Ltd.
Wigan , UK
Intumescent coating
( water based)
Protection of 4-side
exposed hollow
column sections up
to 2 hrs. FRP.
BS 476:
Parts 20 &
21: 1987
UKAS Bodycote
Warringtonfire
WF No.
174358
19 June 2008 valid until
1August
2010
22/7/2008 It should be read in
conjunction with fire
assessment report WF
No. 156367 (expired
on 1.8.2008)
BD-FP
091
Phoenix
270-120
Phoenix Fire
Protection (Asia)
Ltd.
Wigan , UK
Intumescent coating
( water based)
Protection of high
strength steel rod
(MacAlloy Bars) up
to 2 hrs. FRP.
BS 476:
Parts 20 &
21: 1987
UKAS Bodycote
Warringtonfire
WF No.
167802
16 October
2007
valid until
1November
2009
22/7/2008 It should be read in
conjunction with fire
assessment report WF
No. 156367 (expired
on 1.8.2008)
Limiting temperature
for tension rod shall be
evaluated based on the
tensile force of the
member under
consideration.
BD-FP
092
Phoenix
270-120
Phoenix Fire
Protection (Asia)
Ltd.
Wigan , UK
Intumescent coating
( water based)
Protection of 4-side
exposed I- beam
sections up to 2 hrs
FRP.
BS 476:
Parts 20 &
21: 1987
UKAS Bodycote
Warringtonfire
WF No.
174358
19 June 2008 valid until
1August
2010
22/10/2008 It should be read in
conjunction with fire
assessment report WF
No. 156367 (expired
on 1.8.2008)
BD-FP
093
Tanda AP25 Warwick Building
Material Ltd
Guangzhou, China
Single component,
factory blended
cementitious spray
or trowel applied
coating
Protection of 3-side
exposed hollow
beam section; 4-side
exposed hollow
column section and
steel angle section
up to 2 hrs FRP.
BS 476:
Parts 20 &
21: 1987
HOKLAS Rearch
Engineering
Development
Façade
Consultants
Limited
R08C06 9 April 2008 valid until
8 April 2013
22/10/2008
Reference List of Fire Protection Materials for Structural Use
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
094
Nullifire S605 Nullifire Limited
Coventry, UK
Solvent-borne
intumescent coating
Protection of 3-side
exposed I-section
beams and 4-side
exposed I-section
columns & beams up
to 2 hrs FRP.
Protection of 4-side
exposed CHS
columns up to 1 hr.
FRP.
BS 476:
Parts 20 &
21: 1987
UKAS Bodycote
Warringtonfire
WF No
165959
22 January
2008
Valid until
1 February
2013
23/1/2009 This is resulted from
the expiry of BD-FP
025
The relationship
between protection
thickness, section
factor, and fire
resistance period of
structural steel shall
refer to Table 1 & 2 of
report WF No. 165959.
BD-FP
095
Nullifire
System E
Nullifire Limited
Coventry, UK
Intumescent coating Protection of 4-side
exposed CHS up to
1 hr. FRP.
BS 476:
Parts 20 &
21: 1987
UKAS Bodycote
Warringtonfire
WF No
164410A
25 May 2007 Valid until
1 June 2012
23/1/2009 This is resulted from
the expiry of BD-FP
071
It should be read in
conjunction with fire
assessment report
WFRC No. C100578
& WFRC No.
C124329A (expired on
1.11.1999 & 1.5.2007
respectively)
BD-FP
096
Cafco 300 Promat
International
Bankok, Thailand
Plaster/ vermiculite
based product for
internal use.
Protection of 3-side
exposed I-section
beams and 4-side
exposed I-section
columns up to 4 hrs
FRP
BS 476:
Parts 20 &
21: 1987
Recognized by
PNAP 251
Building
Research
Establishment
CC 206998
Review 1
30 April 2007 next review
30 April
2012
23/1/2009 This is resulted from
the expiry of BD-FP
058
It should be read in
conjunction with fire
assessment report CC
206998
Reference List of Fire Protection Materials for Structural Use
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
097
Cafco
Mandolite CP2
Promat
International
Bangkok ,Thailand
Spray applied, single
package factory
controlled premix,
based on vermiculite
and Portland cement
for internal use.
Upgrade reinforced
concrete slabs and
beams up to 4 hrs.
FRP.
BS 476:
Parts 20 &
21: 1987
UKAS Bodycote
Warringtonfire
WF Report
No.
173530/A
Issue 2
28 May 2008 valid until
1 June 2013
23/1/2009 This is resulted from
the expiry of BD-FP
070
It should be read in
conjunction with fire
assessment report
Revision 1
WFRC No CP92117
BD-FP
098
Durasteel Floor
Assemblies
Intumex Asia
Pacific Pte. Ltd.
Blackburn, UK
Single layer of
9.5mm thick
Durasteel board,
fastened below a
framework of steel
channels spaced at
1000 center,
enclosing a cavity
containing 140kg/m3
density rock wool
with a minimum
overall thickness of
120mm.
Insulated ceiling
membrane
construction to
achieve 4 hours FRP
for the underside of
a composite floor
slab formed by steel
profile sheeting.
The ceiling
membrane is hung at
the slab soffit by
M20 steel threaded
hanger rods spaced
at 1200mm.
The ceiling
membrane will not
be subjected to
imposed load except
self weight.
BS 476:
Parts 22:
1987
Recognized by
PNAP 251
Building
Research
Establishment
CC208842
Review 1
6 July 2007 valid until
6 July 2012
23/1/2009 The construction
details should be
identical to those
covered in the
assessment reports.
All requirements given
in the assessment
reports should be
checked to ensure
compatibility with
proposed applications.
Fire stop/ sealant shall
be provided for the
interface between the
perimeter of the
Durasteel floor and the
surrounding structures
Reference List of Fire Protection Materials for Structural Use
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
099
Promatect H Eternit
Guangzhou Co.
Ltd
Guangzhou,
China
Fibre-reinforced
calcium silicate
insulating board.
Protection of steel
beams and columns
up to 2 hrs. FRP.
BS 476:
Parts 20 &
21: 1987
Recognized by
PNAP 251
Building
Research
Establishment
CC84975
Review 5
9 January 2007 9 January
2012
23/1/2009 This is resulted from
the expiry of BD-FP
029
The relationship
between protection
thickness, section
factor, and fire
resistance period of
structural steel shall
refer to Table 3 of
report CC84975
Review 5
BD-FP
100
Monokote
Type Z-146
Grace Korea Inc
Inchon, Korea
Sprayed-applied
cementitious fire
protection material.
Protection of 3-side
exposed or 4-sides
exposed I-section
beams and columns
for FRP up to 1 hr.
Protection of 4-side
exposed hollow
section beams and
column for FRP up
to 1 hr.
BS 476:
Parts 20 &
21: 1987
UKAS Warrington
Fire Research
Centre
WFRC
Report No.
145418
8 March 2005 1 April 2010 23/1/2009 It should be read in
conjunction with fire
assessment report
WFRC No C81831 for
I-section and C109505
for hollow section.
BD-FP
101
Vermitex AF L&A Fazzini
Manufacturing Pty
Ltd.
Greenacre NSW,
Australia
Gypsum-vermiculite
coating
Protection of steel
I-sections, hollow
section and angle
section up to 1 hr.
FRP.
AS 1530.4
and BS 476:
Part 21
NATA CSIRO FCO-1299 1 July 2007 31 July 2012 30/4/2009 According to the
manufacturer’s
recommendation,
Vermitex AF is for
internal application.
BD-FP
102
Tanda AP25 Warwick Building
Material Ltd
Guangzhou, China
Single component,
factory blended
cementitious spray
or trowel applied
coating
Protection of 3-side
and 4-side exposed
I-section up to 4 hrs
FRP.
BS 476:
Parts 20 &
21: 1987
HOKLAS Rearch
Engineering
Development
Façade
Consultants
Limited
R08C06 9 April 2008 8 April 2013 30/4/2009
Reference List of Fire Protection Materials for Structural Use
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
103
Hilti HIT-HY
150
Hilti Corporation
Kaufering,
Gemany
Hybrid resin system Injection system
for making
nominal
anchorage
connections of
Grade 460 rebars
of diameters up
to 25mm in
reinforced
concrete
elements up to 4
hrs. FRP.
BS 476: Part 20:
1987
UKAS Bodycote
Warringtonfire
WF Report
No. 166402
26 October
2007
1 November
2012
30/04/2009 Load carrying capacity
of the injection system
for rebar fixing under
the effects of fire
should be assessed
with an appropriate
factor of safety
compatible with the
structural design of the
parent structure.
BD-FP
104
Interchar 963 International Paint
Limited
Shanghai, China
Intumescent coating Protection of
3-side and 4-side
exposed steel
angles up to 1 hr.
FRP.
BS 476: Parts 20
& 21: 1987
UKAS Bodycote
Warringtonfire
WFRC
Assessment
Report No.
136405
WF Report
No. 179990
15 January
2004
26 January
2009
1 February
2014
NA
12/08/2009
BD-FP
105
Interchar 973 International Paint
Limited
Shanghai, China
Intumescent coating Protection of
4-side exposed
I-section beams
and column up
to 1 hr. FRP.
BS 476: Parts 20
& 21: 1987
UKAS Bodycote
Warringtonfire
WF Report
No. 159150
3 September
2007
1 September
2012
12/08/2009
BD-FP
106
Vermiculux
Board
Intumex Asia
Pacific
Glasgow, UK
Low density
lightweight
non-combustible
board made from a
blend of calcium
silicate, vermiculite
and reinforced with
selected inorganic
fibres and fillers
Protection of
4-side exposed
I-section beams
and columns up
to 4 hrs. FRP.
BS 476: Parts 20
& 21: 1987
N/A Building
Research
Establishment
CC 83123
Review 3
14 July 2008 14 July 2013 12/08/2009 Required thickness of
fire-resisting board
shall be in accordance
with Table 14 of BRE’s
assessment report .CC
83123 Review 3
BD-FP
107
Cafco
SprayFilm
WB3
Cafco International
UK
Guangzhou, China
Intumescent coating Protection of
steel channel
section up to 1
hr. FRP.
BS 476: Parts 20
& 21: 1987
UKAS Bodycote
Warringtonfire
WF Report
No.
176738A
19 September
2008
1 October
2013
4/11/2009 It should be read in
conjunction with
Warringtonfire’s
supplementary letter
176738/RHE.
Reference List of Fire Protection Materials for Structural Use
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
108
Durasteel Floor
Assemblies
Intumex Asia
Pacific Pte. Ltd.
Blackburn, UK
Single layer of
9.5mm thick
Durasteel board,
fastened above and
below a framework
of steel channels,
enclosing a cavity
containing 140kg/m3
density rock wool
with a minimum
overall thickness of
80mm.
Fire resisting
floor assemblies
(construction
details are given
in the assessment
reports) for up to
2 hrs. FRP in
terms of
load-bearing
capacity,
integrity and
insulation.
Maximum
imposed load to
be 7.5kPa.
Additional 2 nos.
of cover strips
shall be required
for the top and
bottom flange of
the channel
sections for
insulation use.
BS 476: Parts 20
& 21: 1987
UKAS Bodycote
Warringtonfire
WF Report
No.
C181794C
30 March
2009
1 April 2014 4/11/2009 It should be read in
conjunction with fire
assessment report No
WFRC 141038.
The construction
details should be
identical to those
covered in the
assessment reports.
All requirements given
in the assessment
reports should be
checked to ensure
compatibility with
proposed applications.
Maximum load ratio of
structural steel
elements inside the
assembly shall be less
than or equal to 0.5
to BS5950: Part 1
Fire stop/ sealant shall
be provided for the
interface between the
perimeter of the
Durasteel floor and the
surrounding structures
BD-FP
109
Firetherm
Firesteel
Classic 120
Firetherm
Intumescent &
Insulation Supplies
Ltd.
Kent, UK
Solvent based
intumescent coating
Protection of
3-sides/ 4-sides
exposed steel
hollow beam
sections and
3-side exposed
steel channel
sections /
I-section up to 2
hrs. FRP.
BS 476: Parts 20
& 21: 1987
UKAS Bodycote
Warringtonfire
WF Report
No.
C155649/A
WF Report
No.
C155649/B
15 June 2006
15 June 2006
1 July 2011
1 July 2011
4/11/2009 It should be read in
conjunction with fire
assessment report
WFRC C130414 &
C130413
Assessment applicable
to steel I-section up to
a maximum web size
of 686mm and flange
size of 305mm
Reference List of Fire Protection Materials for Structural Use
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
110
Unitherm
38091
Sika
Korrosionsshutz
GmbH.
Stuttgart, Gemany
Intumescent coating Protection of
steel I-beams and
I-columns up to
2 hrs. FRP.
BS 476: Parts 20
& 21: 1987
UKAS Bodycote
Warringtonfire
WF Report
No. 162163,
C105561
Issue 2,
C125126,
133000 and
summary
report WF
No. 133394.
19 March
2007
1 April 2012 22/2/2010
BD-FP
111
Unitherm
38091
Sika
Korrosionsshutz
GmbH.
Stuttgart, Gemany
Intumescent coating Protection of
steel RHS up to
2 hrs. FRP.
BS 476: Parts 20
& 21: 1987
UKAS Bodycote
Warringtonfire
WF Report
No. 162164,
C105708,
C125342
Issue 2,
140896 and
summary
report WF
No. 126392
Issue 3..
19 March
2007
1 April 2012 22/2/2010
BD-FP
112
Cafco
SprayFilm
WB3
Cafco International
UK
Guangzhou, China
Intumescent coating Protection of
steel RHS,
channel and
angle section up
to 2 hrs. FRP
BS 476: Parts 20
& 21: 1987
UKAS Bodycote
Warringtonfire
WF Report
No.
176738B for
RHS,
176738A
for channel
and angle
sections
4 April 2009
19 September
2009
1 October
2013
22/2/2010 It should be read in
conjunction with
Warringtonfire’s
supplementary letter
176738/RHE.for
channel and angle
section.
BD-FP
113
Firecut F-1 Yung Chi Paint &
Varnish Mfg. Co.
Ltd
Kaohsiung,
Taiwan
Cementitious
coating
Protection of
steel channel
section up to 1
hr. FRP
BS 476: Parts 20
& 21: 1987
UKAS Bodycote
Warringtonfire
WF Report
No. 149330
Issue 2
18 November
2005
1 December
2010
25/8/2010
BD-FP
114
Isolatek WB3 Isolatek
International
Stanhope, USA
Water-based in
tumescent coating
Protection of
steel channel and
hollow section
up to 2 hrs. FRP.
BS 476: Parts 20
& 21: 1987
UKAS Bodycote
Warringtonfire
WF Report
No.
169583B &
169583C
19 December
2007
1 January
2013
17/10/2011
Reference List of Fire Protection Materials for Structural Use
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
115
Supalux Board Intumex Asia
Pacific
Guangzhou, China
Non-combustible
board
Protection of
steel hollow
section up to1 hr.
FRP.
BS 476: Parts 20
& 21: 1987
N/A Building
Research
Establishment
CC 82876
Review 2
Issue 2
27 March
2006
11 August
2010
17/10/2011 Required thickness of
fire-resisting board
shall be in accordance
with the provision
shown in BRE’s
assessment report
CC 82876 Review 2
Issue 2
BD-FP
116
Nullifire S606 Nullifire Limited
Coventry, UK
Intumescent
coating
Protection of
steel hollow
section, channel
section, I-section
up to 1 hrs. FRP.
BS 476: Parts 20
& 21: 1987
N/A Building
Research
Establishment
CC 92856A
Review 3
CC92856B
Review 3
19 March
2008
next review
date: 10
April 2013
17/10/2011 The relationship
between protection
thickness, section
factor, and fire
resistance of structural
steel shall refer to BRE
assessment report
number CC92856A,
Review 3. and
CC92856B Review 3
BD-FP
117
Monokote
MK6
W.R. Grace & Co.
Incheon City,
South Korea
Sprayed-applied
cementitious
fire-proofing
plaster.
Upgrading of
FRP of RC slab
and beam from 1
hr to 2 hrs.
BS 476: Parts 20
& 21: 1987
UKAS Bodycote
Warringtonfire
WF Report
No. 186522
3 September
2009
1 November
2014
17/10/2011 It should be read in
conjunction with fire
assessment report
WFRC No C107230
BD-FP
118
Firecut F-1 Yung Chi Paint &
Vanish Mfg. Co.
Ltd.
Kaohsiung,
Taiwan
Cementitious fire
rated coating
Protection of
steel channel
section up to
1 hr. FRP.
BS 476: Parts 20
& 21: 1987
UKAS Warrington
Fire Research
Centre
WFRC
Report No.
149330
18 November
2005
1 December
2010
17/10/2011
BD-FP
119
Tanda AP25 Warwick Building
Material Ltd
Guangzhou, China
Single component,
factory blended
cementitious spray
or trowel applied
coating
Protection of
steel channel
section up to 4
hrs FRP.
BS 476: Parts 20
& 21: 1987
HOKLAS Rearch
Engineering
Development
Façade
Consultants
Limited
R08C06 9 April 2008 valid until
8 April 2013
17/10/2011
BD-FP
120
Hensotherm
3KS
Rudolf Hensel
GmbH
Bornsen, Germany
Solvent based
intumescent
coating
Protection of
steel I-section up
to 2 hrs FRP.
BS 476: Parts 20
& 21: 1987
UKAS Bodycote
Warringtonfire
WF Report
No. 170770
28 May 2009 1 June 2014 17/10/2011
Reference List of Fire Protection Materials for Structural Use
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
121
Nullifire
S707-60
Nullifire Limited
Coventry, UK
Intumescent
coating
Protection of
steel I-section up
to 1 hr. FRP.
BS 476: Parts 20
& 21: 1987
UKAS Bodycote
Warringtonfire
WF Report
No. 205546
6 June 2011 next review
date: 1 June
2016
21/9/2012 It should be read in
conjunction with fire
assessment report WF
Report No 154065
BD-FP
122
Cafco
SprayFilm
WB3
Cafco International
UK
Guangzhou, China
Intumescent
coating
Protection of
steel I-section up
to 1 hr. FRP.
BS 476: Parts 20
& 21: 1987
UKAS Bodycote
Warringtonfire
WF Report
No.
176738A
19 September
2008
1 October
2013
21/9/2012 It should be read in
conjunction with fire
assessment report WF
Report No 152624
Issue 3.
BD-FP
123
Firecut F-1 Yung Chi Paint &
Vanish Mfg. Co.
Ltd.
Kaohsiung,
Taiwan
Cementitious fire
rated coating
Protection of
steel I-section,
steel channel
section and angle
section up to 4
hrs. FRP.
BS 476: Parts 20
& 21: 1987
UKAS Bodycote
Warringtonfire
WFRC
Report No.
179160
11 December
2008
1 January
2014
21/9/2012
BD-FP
124
Firetherm
Firesteel
120WB
Firetherm
Intumescent &
Insulation Supplies
Ltd.
Kent, UK
Water borne
intumescent
coating
Protection of
3-sides/ 4-sides
exposed steel
I-section and
4-side exposed
steel hollow
section up to 2
hrs. FRP.
BS 476: Parts 20
& 21: 1987
UKAS Bodycote
Warringtonfire
WF Report
No. 169988
28 January
2008
1 February
2013
3/7/2013
Reference List of Fire Protection Materials for Structural Use
Ref.
No.
Product
Name
Name of
Manufacturer
and Place of
Manufacture
(City and
Country)
Material
Category Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of
Posting on
CDB
Remarks /
Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP
125
Durasteel Floor
Assemblies
Intumex Asia
Pacific Pte. Ltd.
Blackburn, UK /
Zhejiang, PRC
Single layer of
9.5mm thick
Durasteel board,
fastened above and
below a framework
of steel channels,
enclosing a cavity
containing
140kg/m3 density
rock wool with a
minimum overall
thickness of
80mm.
Fire resisting
floor assemblies
(construction
details are given
in the assessment
report) for up to
1 hr. FRP in
terms of
load-bearing
capacity,
integrity and
insulation.
Maximum
imposed load to
be 10kPa.
Additional 1 no.
of 9.5mm thick
Durasteel cover
strip shall be
required for the
top and bottom
flange of the
channel sections
for insulation
use.
BS 476: Parts 20
& 21: 1987
Department of
Standards
Malaysia
UKAS
Fire Science
Research
Group
(Malaysia)
Exova
Warringtonfire
FSRG
2014/005
WF Report
No. 189172
27 February
2014
21 December
2009
NA
1 January
2015
9 June 2014 The construction
details should be
identical to those
covered in the
assessment report.
All requirements given
in the assessment
reports should be
checked to ensure
compatibility with
proposed applications.
The assembly shall be
supported by structural
members with fire
protection system for
the relevant fire
resistance period.
Fire stop/ sealant shall
be provided for the
interface between the
perimeter of the
Durasteel floor and the
surrounding structures
BD-FP
126
Firecut
FM-900
Yung Chi Paint &
Varnish Mfg Co
Ltd.
Koahsiung,
Taiwan
Single pack
solvent based
intumescent
coating
Protection of
steel I-sections
with 3-side or
4-side exposed
up to 2 hrs. FRP.
BS 476: Parts 20
& 21: 1987
UKAS Exova
Warringtonfire
WF Review
Report No.
316831
23 March
2012
1 April 2017 9 June 2014 It should be read in
conjunction with
Bodycote
Warringtonfire fire
assessment report WF
No. 167317.
BD-FP
127
Firecut
FM-900
Yung Chi Paint &
Varnish Mfg Co
Ltd.
Koahsiung,
Taiwan
Single pack
solvent based
intumescent
coating
Protection of
steel angle,
channel and
I-sections with
3-side or 4-side
exposed to 1 hr.
FRP.
BS 476: Parts 20
& 21: 1987
UKAS Bodycote
Warringtonfire
WF Review
Report No.
307644
16 May 2011 1 June 2016 9 June 2014 It should be read in
conjunction with
Bodycote
Warringtonfire
assessment report WF
No. 145918.
Reference List of Fire Protection Materials for Structural Use
Ref. No.
Product Name
Name of Manufacturer and Place of Manufacture
(City and Country)
Material Category
Application Compliance
Testing
Standard
Details of Test or Assessment Report Date of Posting on
CDB
Remarks / Comments
Name of
Laboratory
Accreditation
Body
Name of
Laboratory /
Assessing
Organization
Report No. Date of Test /
Assessment
Report
Validity
Date
BD-FP 128
Ramset EPCON G5 Injection Adhesive with Grade 460 high yield deformed bars of diameters 12mm to 40mm
ITW Red Head
Illinois, USA Epoxy injection system
Injection system for making anchorage connections of Grade 460 rebars of diameters 12mm to 40mm in reinforced concrete elements up to 4 hrs. FRP.
BS 476: Part 20: 1987
UKAS Exova Warringtonfire
EWFA Report No. 25276-00
30 September 2010
30 November
2015
01/09/2014 It should be read in conjunction with Warringtonfire assessment report no. 45838.4.
Load carrying capacity of the injection system for rebar fixing under the effects of fire should be assessed with an appropriate factor of safety compatible with the structural design of the parent structure.
BD-FP 129
Firetex FX-5090
Sherwin-Williams Protective & Marine Coating
Bolton, UK
Intumescent coating
(water based)
Protection of steel I-sections and hollow sections with 3-side or 4-side exposed up to 2 hrs. FRP.
BS 476: Parts 20 & 21: 1987
UKAS Exova Warringtonfire
WF Report No. 336628
WF Report No. 347568
28 January 2014
9 July 2015
1 February 2019
1 June 2020
31 August 2016
The construction details should be identical to those covered in the assessment reports. All requirements given in the assessment reports should be checked to ensure compatibility with proposed applications.
BD-FP 130
Sika Unitherm Platinum-120
Sika Korrosionsshutz GmbH. Stuttgart, Germany
Intumescent coating
Protection of steel Rectangular and Circular Hollow columns up to 120 mins. FRR.
BS 476: Parts 20 & 21: 1987
UKAS Warringtonfire Testing and Certification Limited
WF Report No. 352248 issue 3
17 July 2019 1 August 2024
30 December 2019
The construction details should be identical to those covered in the assessment reports.