561-MB256 plusIntrusion detection central control unit
Performance features
The intrusion detection control unit 561-MB256 isdesigned for use in private and commercial zones and ishighly suitable for setting up medium to large-sizedhazard detection systems.
It complies with the latest guidelines of the VdS SecurityClass C as well as the German Electrical Standards0833, Part 1 and Part 3 of Class 1, Version B.
The standard version of the 561-MB256 has thefollowing performance features:
4 conventional detector group inputs
63 BUS-1 users - connectable
64 BUS-2 users - connectable
8 freely programmable semi-conductor outputs
as well as 4 freely programmable relays
Integrated, monitored alarm signalling device
connections
Serial and parallel printer interface
With the corresponding extension modules as well asBUS-1 and BUS-2 users, a total of 2048 detector groupscan be realized. When fully equipped with 32 I/Omodules, 1028 conventional inputs (terminating value12.1 kOhm) are available that can be used as inputs fordetectors and switching devices.
plus
plus
Up to 2048 detector groups can be defined, ofwhich 1028 are conventional detector groups
Up to 250 main zones can be defined Up to 2583 BUS-1 users can be connected Up to 704 BUS-2 users can be connected, of
which max. 50 are operating units Suitable for police emergency call 19" version and add-on operating unit Available with LCD operating unit and printer
depending on version Programming via USB in conjunction with
PCB/laptop and software package WINFEMAdvanced
Simple firmware update with Flash-EPROM
Operator guidance with plain text display Modular extensible up to max. 32 modules Automatic maintenance interval indication IGIS-LOOP and transmission devices can be
integrated (also multiple) Event memory for 4000 events Alarm memory - 20 events per main zone
1000 IDENT-KEY data carrier codes can bemanaged; up to 250 macros can be defined
Access with or without code; up to 750 operatingcodes; every operating function can beenabled/disabled individually.
Technical and fire alarm memory
With maximum upgrading with BUS-1 and BUS-2modules, up to 2583 BUS-1 users and 704 BUS-2 userscan be connected. Several detector group inputs and/orBUS users can be allocated to one detector group.Logical relationships of the individual detector groups tothe object-specific conditions are thus possible.
The central control units are mounted in the standardhousing type ZG 4. The extension modules are mountedon the back of the housing and interconnected via a flatband cable. In addition to the central control units in thehousing type ZG 4, 19 versions are also available. Thecentral control unit in the housing type ZG 4 as well asthe 19" versions, are each available with or without anintegrated printer.
The power supply (option) can be made via one orseveral power supplies/charger units of 17 Ah to 130 Ahdepending on the size of the system.
The central control units are easy to program with aPC/laptop via the parameterization software WINFEMAdvanced. Remote programming or remote control isalso possible in conjunction with a transmission deviceand WINFEM Advanced,
Options/accessories
Technical data
Rated connection voltageRated operating voltage U_bCurrent consumption at U_b, disarmed, w/o extensionEnvironmental class as per VdSProtection class as per DIN 40 050Operating temperature rangeDimensions W x H x D: Housing type ZG 4
19" versionColour: Housing
230 V AC / 50 Hz12 V DCmax. 140 mAIIIP 30-10 C to +50 C580 x 640 x 300 mm488 x 272 x 110 mm (incl. printer)grey white (similar to RAL 9002)signal grey (similar to RAL 7004)Front
Honeywell Security DeutschlandNovar GmbHJohannes-Mauthe-Str. 14D-72458 AlbstadtTelefon: +49 (0) 74 31 / 801-0Telefax: +49 (0) 74 31 / 801-12 20www.honeywell.com/security/[email protected]
P00169-22-0G0-0103.2006 Subject to alteration 2006 Novar GmbH
Optional extension modules
013220.04Connection moduleModule with slot for acoustic plug-in card and radio card.Equipped with 4 x 250 V AC / 5 A and 4 x 24 V DC / 1 A relays. 10 programmable12 V / 50 mA semi-conductor outputs as well as a main and permanent alarm outputcan be used to actuate the relays or as a semi-conductor output.
013220.05I/O basic moduleModule with 32 inputs for connecting one or several conventional detectors orswitching elements, e.g. block locks or operating units. Also available are 48 program-mable semi-conductor outputs, 32 of which can be used via programming connectorsfor clearing detector groups.
013220.11BUS-1 moduleExtension module for connecting up to 252 users. 4 independent connectionsindividually protected by fuse are available for BUS-1 users. Up to 63 BUS-1 users arepossible per connection.
013220.07BUS-2 moduleExtension module for connection BUS-2 users. 4 connections,
individually protected by fuse, are available for a total of 64 BUS-2 users.isolated against each
other and
013230Retrofit kit IDC 561-MB256 to IDCU 561-MB256 plusThis retrofit kit enables a central control unit 561-MB256 to be retrofitted to a centralcontrol unit 561-MB256 . The retrofit kit comprises the computer/connection PCB,adapter PCB for the serial printer, the assembly adapter plate, all necessary mountingand installation material as well as WINFEM Advanced.
plus
013330.10IGIS-LOOP controllerExtension module for integrating intrusion detection central control units in the IGIS-LOOP network. The IGIS-LOOP controller is the central module of the IGIS-LOOPsecurity network. If the controllers are connected in a ring, they form the core of theIGIS-LOOP.
013220.06Keypad moduleThe module enables the connection up to 4 keypad units with a matrix connection(3/4).Note: Max. 25 keypad modules can be used.
013100.08Relay extension moduleThe relay extension module is equipped with 4 x 250 V AC / 5 A relays as well as 2slots for group relay cards 070478. The module is not designed for connecting to theI-BUS. The relays are actuated via conventional connections (e.g. programmablesemi-conductor outputs).
013220.14Connection PCB for table-top printerExternal table-top printers with a parallel interface can be controlled with this PCB.With the PCB, a galvanic separation is possible between the intrusion detectioncentral control unit and the printer although the non-reactive operation of an externalprinter is guaranteed.
Housings
Relay extension
Printer/printer accessories
Power supply/charger units
RDT/transmission devices
050055 19" housing type ZG 4050056 19" housing type ZG 5050057 19" housing type ZG 6013118 19" dummy plate 6 HU, signal grey013119 19" dummy plate 3 HU, signal grey
070478 Group relay card
013900 Alphanumerical thermoprinter40-digit, with motor-driven spooling
010686.01 Power supply/charger unit 12 V DC / 17 Ah010690.01 Power supply/charger unit 12 V DC / 32 Ah010690.02 Power supply/charger unit 12 V DC / 40 Ah012168 Power supply/charger unit 12 V DC / 80 Ah012170 Power supply/charger unit 12 V DC /130 Ah050019 Distributor block
057870 Motherboard DS 6500057630 Motherboard DS 7500 ISDN057640 Motherboard DS 7500 ISDN/analogous057875 Motherboard DS 8500 ISDN057876 Motherboard DS 8500 ISDN/analogous057650 Motherboard DS 7600 ISDN057651 Motherboard DS 7700 ISDN/IP057920 Motherboard DGA 2400
WINFEM central control unit programming
013901 Paper roll (PU 5 pieces)
013498 Parameterization softwareWINFEM Advanced
026809 Zero modem cable013466 Adapter cable with 3-pole plug connector013467 USB adapter box (USB 1.1-compatible)013595 WINFEM user; Windows software for
programming on user level
013100.10 Connection cable 40 mm / 250 mm013100.11 Connection cable 400 mm013100.12 Connection cable 250 mm013100.13 Connection cable 1000 mm013100.14 Connection cable 650 mm
Connection cables
BUS-1 user
BUS-2 user
BUS-2 operating units
010109.10 1-detector group module010110.10 2-detector group module010118 2-detector group module; f.m. version010111 Universal connection module; s.m. version010112 Universal connection module; f.m. version010116 Active distributor module010125 Key switch - operating unit BUS-1015128 Radio receiver module022310.10 Door module 1022320.10 Door module 2031540 Hold-up pushbutton module032211 IDENTLOC evaluation unit032420 DETEKT 1000033370/033371/033372 PIR detector SCM 2000033401/033404/033407 PIR detector SCM 3000041150.10 Switching module 24 V DC / 1 A041151.10 Switching module 250 V AC / 5 A042235 Indoor blinking light043050 Indoor siren module043060 Piezo indoor siren062085 Smoke detector base module
013130.10 5 Input module013131.10 5 Output module022160.20 IDENT-KEY IK2 evaluation unit023312.10 IDENT-KEY IK3 evaluation unit033402/033405/033408 PIR motion detector SCM 3000 / A
012540 2 x 40-digit LCD operating unit; with flap012541 2 x 40-digit LCD operating unit; w/o flap012544 10-DG oper. unit with disabling function012532 8-DG oper. unit with disabling function012542 16-DG disabling and display module012548 16-DG display module012546 flush mounting kit for 012532, 012541,012542,
012544, 012548013140 64 DG display terminal
033442 Viewguard DUAL AM BUS-2033443 Viewguard DUAL BUS-2
Retrofit - central control units
-approval pending
013222.10Intrusion detection central control unit 561-MB256 in housing Type ZG 4plus
013223.10Intrusion detection central control unit 561-MB256 in housing type ZG 4,incl. printer
plus
013224.10Intrusion detection central control unit 561-MB256 19" versionplus
013225.10Intrusion detection central control unit 561-MB256 19" version,incl. printer
plus
013228.10Intrusion detection central control unit 561-MB256 19" version,with operating unit
plus
013229.10Intrusion detection central control unit 561-MB256 19" version,with operating unit including printer
plus
Space for 8 options; space for power supply/charger unit; max. space foraccumulator 2 x 65 Ah
Slot for 8 options; space for power supply/charger unit; max. space foraccumulator 2 x 65 Ah
Computer/connection PCB;Housing type ZG 4; front plate 6 HU; dummy plate 6 HU
Computer/connection PCB; thermoprinter 103900; housing Type ZG 4;front plate 6 HU; dummy plate 6 HU
Computer/connection PCB; front plate 6 HU
Computer/connection PCB; thermoprinter 013900; front plate 6 HU
Computer/connection PCB; operating unit 012541; front plate 6 HU
Computer/connection PCB; operating unit 012541; thermoprinter 013900;front plate 6 HU
-approval pending