2
  S y s t em C u r ve System  An overview Sys tem cur ve equation (as a function of flow) for single outlet system (one discharge line) is given below:   =   +   +   +    whereby      is friction head       is equipment head      is velocity head    is Total Static head   The System curve is superimposed on the Pump Head curve and the intersecting point is the Operating Point of the particular system. It indicates the Total Head required from the pump to establish the required flow (capacity) at the Operating point. V Kumaran Oct 2015 152 14/10/2015 H ead Loss

Centrifugal Pump (Revised Nov 2015)

Embed Size (px)

Citation preview

Page 1: Centrifugal Pump (Revised Nov 2015)

7/23/2019 Centrifugal Pump (Revised Nov 2015)

http://slidepdf.com/reader/full/centrifugal-pump-revised-nov-2015 1/1

 

Sy st em Cu r v e

• System

 An overview System curve equation (as a function of flow) for single

outlet system (one discharge line) is given below:

  ∆ = ∆   + ∆   + ∆   + ∆ 

 whereby  ∆    is friction head 

 ∆    is equipment head

  ∆    is velocity head

  ∆ is Total Static head 

The System curve is superimposed on the Pump Head curve and theintersecting point is the Operating Point of the particular system.

It indicates the Total Head required from the pump to establish the

required flow (capacity) at the Operating point. 

V Kumaran Oct 2015 15214/10/2015

H ead L oss