4
Reporting Limit 10 ppm *Total CBD = CBD + CBDA x 0.877 N/D - Not Detected, B/LOQ - Below Limit of Quantification CERTIFICATE OF ANALYSIS ISO/IEC 17025:2017 ACCREDITATION #103104 Order #: 67995 Order Name: CBD Hemp Extract Batch#: 3232020NOHE12 Received: 12/28/2020 Completed: 01/07/2021 Upstate Elevator Supply Co. 388 Pine St. Suite 2 Burlington VT, 05401 (888) 640-2155 [email protected] Sample 2.709% D9-THC 68.945% Total CBD Cannabinoids Test SHIMADZU INTEGRATED UPLC-PDA GSL SOP 400 UPLOADED: 12/30/2020 12:23:20 Cannabinoids LOQ weight(%) mg/g D9-THC 10 PPM 2.709% 27.089 THCA 10 PPM 0.057% 0.568 CBD 10 PPM 68.807% 688.071 CBDA 20 PPM 0.157% 1.567 CBDV 20 PPM 0.358% 3.578 CBC 10 PPM 2.894% 28.941 CBN 10 PPM 0.065% 0.652 CBG 10 PPM 1.283% 12.830 CBGA 20 PPM N/D N/D D8-THC 10 PPM N/D N/D THCV 10 PPM 0.140% 1.397 TOTAL D9-THC 2.709% 2.709% TOTAL CBD* 68.945% 689.445 TOTAL CANNABINOIDS 76.470% 764.693 Dr. Andrew Hall, Ph.D.,Chief Scientific Officer Ben Witten, MS, MT., Lab Director Green Scientific Labs [email protected] 1-833 TEST CBD Green Scientific Labs uses its best efforts to deliver high quality results and to verify that the data contained therein are based on sound scientific judgment and levels listed are guidelines only and all data was reported based on standard laboratory procedures and deviations. However Green Scientific Labs makes no warranties or claims to that effect and further shall not be liable for any damage or misrepresentation that may result from the use or misuse of the data contained herein in any way. Further, Green Scientific Labs makes no claims regarding representations of the analyzed sample to the larger batch from which it was taken. Data and information in this report are intended solely for the individual(s) for whom samples were submitted and as part of our strict confidentiality policy, Green Scientific Labs can only discuss results with the original client of record.

CERTIFICATE OF ANALYSIS · 2021. 2. 3. · Metal Action Level (ppb) Result (ppb) ARSENIC (AS) 200 B/LOQ CADMIUM (CD) 200 B/LOQ MERCURY (HG) 100 B/LOQ LEAD (PB) 500 135 Lower Limit

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

  • Reporting Limit 10 ppm *Total CBD = CBD + CBDA x 0.877 N/D - Not Detected, B/LOQ - Below Limit of Quantification

    CERTIFICATE OF ANALYSISISO/IEC 17025:2017 ACCREDITATION #103104

    Order #: 67995Order Name: CBD HempExtractBatch#: 3232020NOHE12Received: 12/28/2020Completed: 01/07/2021

    Upstate Elevator Supply Co.388 Pine St. Suite 2Burlington VT, 05401(888) [email protected]

    Sample

    2.709% D9-THC

    68.945% Total CBD

    Cannabinoids TestSHIMADZU INTEGRATED UPLC-PDAGSL SOP 400 UPLOADED: 12/30/2020 12:23:20 Cannabinoids LOQ weight(%) mg/gD9-THC 10 PPM 2.709% 27.089THCA 10 PPM 0.057% 0.568CBD 10 PPM 68.807% 688.071CBDA 20 PPM 0.157% 1.567CBDV 20 PPM 0.358% 3.578CBC 10 PPM 2.894% 28.941CBN 10 PPM 0.065% 0.652CBG 10 PPM 1.283% 12.830CBGA 20 PPM N/D N/DD8-THC 10 PPM N/D N/DTHCV 10 PPM 0.140% 1.397

    TOTAL D9-THC 2.709% 2.709%TOTAL CBD* 68.945% 689.445TOTAL CANNABINOIDS 76.470% 764.693

    Dr. Andrew Hall, Ph.D.,Chief Scientific Officer Ben Witten, MS, MT., Lab Director

    Green Scientific [email protected]

    1-833 TEST CBD

    Green Scientific Labs uses its best efforts to deliver high quality results and to verify that the data contained therein are based on sound scientific judgment and levels listed are guidelines only and all data wasreported based on standard laboratory procedures and deviations. However Green Scientific Labs makes no warranties or claims to that effect and further shall not be liable for any damage or misrepresentation thatmay result from the use or misuse of the data contained herein in any way. Further, Green Scientific Labs makes no claims regarding representations of the analyzed sample to the larger batch from which it wastaken. Data and information in this report are intended solely for the individual(s) for whom samples were submitted and as part of our strict confidentiality policy, Green Scientific Labs can only discuss results withthe original client of record.

  • PESTICIDE ANALYSIS:GSL SOP 401 PREPARED: 12/29/2020 16:28:57 UPLOADED: 12/30/2020 15:31:11

    N/D = Not Detected, A/LOQ = Above LOQ Level, B/LOQ = Below LOQ Level, B/LOD = Below LOD Level

    CERTIFICATE OF ANALYSISISO/IEC 17025:2017 ACCREDITATION #103104

    Order #: 67995Order Name: CBD HempExtractBatch#: 3232020NOHE12Received: 12/28/2020Completed: 01/07/2021

    Upstate Elevator Supply Co.388 Pine St. Suite 2Burlington VT, 05401(888) [email protected]

    GCMS-MS - Shimadzu GCMS-TQ8040

    Pesticide Action Level(ppm)Results(ppm)

    LOQ(ppm)

    LOD(ppm)

    CAPTAN 0.700 N/D 0.003 0.001CHLORDANE 0.100 N/D 0.003 0.001CHLORFENAPYR 0.100 N/D 0.003 0.001COUMAPHOS 0.100 N/D 0.003 0.001

    Pesticide Action Level(ppm)Results(ppm)

    LOQ(ppm)

    LOD(ppm)

    CYFLUTHRIN 2.000 N/D 0.003 0.001CYPERMETHRIN 1.000 N/D 0.003 0.001PARATHION-METHYL 0.100 N/D 0.003 0.001PENTACHLORONITROBENZENE 0.100 N/D 0.003 0.001

    LCMS-MS - Shimadzu LCMS-8060

    Pesticide Action Level(ppm)Results(ppm)

    LOQ(ppm)

    LOD(ppm)

    ABAMECTIN B1A 0.100 N/D 0.005 0.001ACEPHATE 0.100 N/D 0.001 0.001ACEQUINOCYL 0.100 N/D 0.001 0.001ACETAMIPRID 0.100 N/D 0.005 0.001ALDICARB 0.100 N/D 0.005 0.001AZOXYSTROBIN 0.100 N/D 0.001 0.001BIFENAZATE 0.100 N/D 0.005 0.001BIFENTHRIN 3.000 N/D 0.005 0.001BOSCALID 0.100 N/D 0.005 0.001CARBARYL 0.500 N/D 0.003 0.001CARBOFURAN 0.100 N/D 0.001 0.001CHLORANTRANILIPROLE 10.000 N/D 0.005 0.005CHLORPYRIFOS 0.100 N/D 0.001 0.001CLOFENTEZINE 0.100 N/D 0.001 0.001DAMINOZIDE 0.100 N/D 0.005 0.001DIAZINON 0.100 N/D 0.001 0.001DICHLORVOS 0.100 N/D 0.005 0.001DIMETHOATE 0.100 N/D 0.001 0.001DIMETHOMORPH 2.000 N/D 0.005 0.001ETHOPROPHOS 0.100 N/D 0.001 0.001ETOFENPROX 0.100 N/D 0.001 0.001ETOXAZOLE 0.100 N/D 0.010 0.005FENHEXAMID 0.100 N/D 0.005 0.001FENOXYCARB 0.100 N/D 0.005 0.001FENPYROXIMATE 0.100 N/D 0.001 0.001FIPRONIL 0.100 N/D 0.003 0.001FLONICAMID 0.100 N/D 0.025 0.010FLUDIOXONIL 0.100 N/D 0.003 0.001HEXYTHIAZOX 0.100 N/D 0.005 0.001IMAZALIL 0.100 N/D 0.005 0.001

    Pesticide Action Level(ppm)Results(ppm)

    LOQ(ppm)

    LOD(ppm)

    IMIDACLOPRID 5.000 N/D 0.005 0.001KRESOXIM-METHYL 0.100 N/D 0.010 0.005MALATHION 0.500 N/D 0.005 0.001METALAXYL 2.000 N/D 0.001 0.001METHIOCARB 0.100 N/D 0.005 0.001METHOMYL 1.000 N/D 0.001 0.001MEVINPHOS 0.100 N/D 0.001 0.001MYCLOBUTANIL 0.100 N/D 0.005 0.001NALED 0.100 N/D 0.005 0.001OXAMYL 0.500 N/D 0.001 0.001PACLOBUTRAZOL 0.100 N/D 0.005 0.001PERMETHRINS 0.500 N/D 0.005 0.001PHOSMET 0.100 N/D 0.005 0.001PIPERONYLBUTOXIDE

    3.000 N/D 0.001 0.001

    PRALLETHRIN 0.100 N/D 0.005 0.005PROPICONAZOLE 0.100 N/D 0.010 0.005PROPOXUR 0.100 N/D 0.001 0.001PYRETHRINS(PYRETHRIN I)

    0.500 N/D 0.005 0.005

    PYRIDABEN 0.100 N/D 0.005 0.001SPINETORAM 0.100 N/D 0.001 0.001SPINOSAD 0.100 N/D 0.001 0.001SPIROMESIFEN 0.100 N/D 0.005 0.001SPIROTETRAMAT 0.100 N/D 0.001 0.001SPIROXAMINE 0.100 N/D 0.001 0.001TEBUCONAZOLE 0.100 N/D 0.005 0.001THIACLOPRID 0.100 N/D 0.001 0.001THIAMETHOXAM 5.000 N/D 0.001 0.001TRIFLOXYSTROBIN 0.100 N/D 0.001 0.001

    Dr. Andrew Hall, Ph.D.,Chief Scientific Officer Ben Witten, MS, MT., Lab Director

    Green Scientific [email protected]

    1-833 TEST CBD

    Green Scientific Labs uses its best efforts to deliver high quality results and to verify that the data contained therein are based on sound scientific judgment and levels listed are guidelines only and all data wasreported based on standard laboratory procedures and deviations. However Green Scientific Labs makes no warranties or claims to that effect and further shall not be liable for any damage or misrepresentation thatmay result from the use or misuse of the data contained herein in any way. Further, Green Scientific Labs makes no claims regarding representations of the analyzed sample to the larger batch from which it wastaken. Data and information in this report are intended solely for the individual(s) for whom samples were submitted and as part of our strict confidentiality policy, Green Scientific Labs can only discuss results withthe original client of record.

  • fa

    † USP 61 (enumeration of bacteria TAC, TYM, and ENT/Coliform), USP 62 (identifying specific species E.coli Aspergillus etc) * STEC and Salmonella run as Multiplex ** CFU/g Calculation based on MIP/Extract matrix *** Flavus = 2 Copies of DNA / Fumigatis = 2 Copies of DNA Niger = 20 Copies of DNA / Terrus = 10 copies of DNA

    CERTIFICATE OF ANALYSISISO/IEC 17025:2017 ACCREDITATION #103104

    Order #: 67995Order Name: CBD HempExtractBatch#: 3232020NOHE12Received: 12/28/2020Completed: 01/07/2021

    Upstate Elevator Supply Co.388 Pine St. Suite 2Burlington VT, 05401(888) [email protected]

    Microbial Analysis:PCR - Agilent AriaMX

    Microbial Analysis GSL SOP 406 Uploaded: 01/05/2021 11:42:04

    MICROBIAL ANALYSIS:

    Test SOP Test Method Device Used LOD AllowableCriteria Actual Result Pass/Fail

    ASPERGILLUS FUMIGATUS*** 406.01 USP 61/62† ARIAMX PCR 1 CFU/G**DETECT/NOTDETECTED

    NOT DETECTED PASS

    ASPERGILLUS TERREUS*** 406.01 USP 61/62† ARIAMX PCR 1 CFU/G**DETECT/NOTDETECTED

    NOT DETECTED PASS

    ASPERGILLUS FLAVUS*** 406.01 USP 61/62† ARIAMX PCR 1 CFU/G**DETECT/NOTDETECTED

    NOT DETECTED PASS

    ASPERGILLUS NIGER*** 406.01 USP 61/62† ARIAMX PCR 1 CFU/G**DETECT/NOTDETECTED

    NOT DETECTED PASS

    STEC E. COLI* 406.01 USP 61/62† ARIAMX PCR 1 CFU/G**DETECT/NOTDETECTED

    NOT DETECTED PASS

    SALMONELLA* 406.01 USP 61/62† ARIAMX PCR 1 CFU/G**DETECT/NOTDETECTED

    NOT DETECTED PASS

    TOTAL YEAST AND MOLD 406.01 USP 61/62† ARIAMX PCRCFU/G BYSAMPLETYPE**

    1,000 CFU/G NOT DETECTED PASS

    AEROBIC BACTERIA COUNT 406.01 USP 61/62† ARIAMX PCRCFU/G BYSAMPLETYPE**

    10,000 CFU/G NOT DETECTED PASS

    ENTEROBACTERIACEAE 406.01 USP 61/62† ARIAMX PCRCFU/G BYSAMPLETYPE**

    100 CFU/G NOT DETECTED PASS

    COLIFORM 406.01 USP 61/62† ARIAMX PCRCFU/G BYSAMPLETYPE**

    100 CFU/G NOT DETECTED PASS

    PCR - Agilent AriaMX

    Dr. Andrew Hall, Ph.D.,Chief Scientific Officer Ben Witten, MS, MT., Lab Director

    Green Scientific [email protected]

    1-833 TEST CBD

    Green Scientific Labs uses its best efforts to deliver high quality results and to verify that the data contained therein are based on sound scientific judgment and levels listed are guidelines only and all data wasreported based on standard laboratory procedures and deviations. However Green Scientific Labs makes no warranties or claims to that effect and further shall not be liable for any damage or misrepresentation thatmay result from the use or misuse of the data contained herein in any way. Further, Green Scientific Labs makes no claims regarding representations of the analyzed sample to the larger batch from which it wastaken. Data and information in this report are intended solely for the individual(s) for whom samples were submitted and as part of our strict confidentiality policy, Green Scientific Labs can only discuss results withthe original client of record.

  • CERTIFICATE OF ANALYSISISO/IEC 17025:2017 ACCREDITATION #103104

    Order #: 67995Order Name: CBD HempExtractBatch#: 3232020NOHE12Received: 12/28/2020Completed: 01/07/2021

    Upstate Elevator Supply Co.388 Pine St. Suite 2Burlington VT, 05401(888) [email protected]

    Mycotoxin Analysis:LC-MS - Shimadzu LCMS-8060GSL SOP 401 Uploaded: 12/30/2020 15:31:03

    Analyte Action Lvl (ppb) Results (ppb)AFLATOXIN B1 20 N/DAFLATOXIN B2 20 N/DAFLATOXIN G1 20 N/DAFLATOXIN G2 20 N/DOCHRATOXIN A 20 N/D

    LOQ is 1ppb, LOD is 1ppb

    Heavy Metals Analysis:ICP-MS - Shimadzu ICPMS-2030GSL SOP 403 Uploaded: 01/07/2021 08:10:32

    Metal Action Level (ppb) Result (ppb)ARSENIC (AS) 200 B/LOQCADMIUM (CD) 200 B/LOQMERCURY (HG) 100 B/LOQLEAD (PB) 500 135

    Lower Limit of Quantitation (LOQ) is 75 ppb

    Dr. Andrew Hall, Ph.D.,Chief Scientific Officer Ben Witten, MS, MT., Lab Director

    Green Scientific [email protected]

    1-833 TEST CBD

    Green Scientific Labs uses its best efforts to deliver high quality results and to verify that the data contained therein are based on sound scientific judgment and levels listed are guidelines only and all data wasreported based on standard laboratory procedures and deviations. However Green Scientific Labs makes no warranties or claims to that effect and further shall not be liable for any damage or misrepresentation thatmay result from the use or misuse of the data contained herein in any way. Further, Green Scientific Labs makes no claims regarding representations of the analyzed sample to the larger batch from which it wastaken. Data and information in this report are intended solely for the individual(s) for whom samples were submitted and as part of our strict confidentiality policy, Green Scientific Labs can only discuss results withthe original client of record.