4
Reporting Limit 10 ppm *Total CBD = CBD + CBDA x 0.877 N/D - Not Detected, B/LOQ - Below Limit of Quantification CERTIFICATE OF ANALYSIS Order #: 32172 Order Name: veré full spectrum Batch#: fw190429t500m Received: 06/11/2019 Completed: 06/18/2019 Veré Health & Wellness PO Box 454 Pompton Lakes NJ, 07442 (800) 805-1024 [email protected] Sample 0.072% D9-THC 1.990% Total CBD Cannabinoids Test GSL SOP 400 PREPARED: 06/11/2019 21:38:31 UPLOADED: 06/12/2019 16:50:40 cannabinoids weight(%) mg/g DELTA-9-TETRAHYDROCANNABINOL D9-THC 0.072% 0.723 TETRAHYDROCANNABINOLIC ACID THCA N/D N/D CANNABIDIOL CBD 1.962% 19.623 CANNABIDIOLIC ACID CBDA 0.032% 0.321 CANNABIDIVARIN CBDV 0.009% 0.091 CANNABICHROMENE CBC 0.146% 1.456 CANNABINOL CBN N/D N/D CANNABIGEROL CBG 0.042% 0.424 CANNABIGEROLIC ACID CBGA N/D N/D DELTA-8-TETRAHYDROCANNABINOL D8-THC 0.003% 0.029 TETRAHYDROCANNABIVARIN THCV N/D N/D TOTAL D9-THC 0.072% 0.723 TOTAL CBD* 1.990% 19.905 TOTAL CANNABINOIDS 2.266% 22.667 Notes Approximately 618.8mg cannabinoids per 30mL 4001 SW 47th Avenue Suite 207 Davie, FL 33314 1-833-TEST-CBD [email protected] Green Scientific Labs uses its best efforts to deliver high quality results and to verify that the data contained therein are based on sound scientific judgment and levels listed are guidelines only and all data was reported based on standard laboratory procedures and deviations. However Green Scientific Labs makes no warranties or claims to that effect and further shall not be liable for any damage or misrepresentation that may result from the use or misuse of the data contained herein in any way. Further, Green Scientific Labs makes no claims regarding representations of the analyzed sample to the larger batch from which it was taken. Data and information in this report are intended solely for the individual(s) for whom samples were submitted and as part of our strict confidentiality policy, Green Scientific Labs can only discuss results with the original client of record.

CERTIFICATE OF ANALYSIS€¦ · CERTIFICATE OF ANALYSIS Order #: 32172 Order Name: veré full spectrum Batch#: fw190429t500m Received: 06/11/2019 Completed: 06/18/2019 Veré Health

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CERTIFICATE OF ANALYSIS€¦ · CERTIFICATE OF ANALYSIS Order #: 32172 Order Name: veré full spectrum Batch#: fw190429t500m Received: 06/11/2019 Completed: 06/18/2019 Veré Health

Reporting Limit 10 ppm *Total CBD = CBD + CBDA x 0.877 N/D - Not Detected, B/LOQ - Below Limit of Quantification

CERTIFICATE OF ANALYSISOrder #: 32172Order Name: veré full spectrumBatch#: fw190429t500mReceived: 06/11/2019Completed: 06/18/2019

Veré Health & WellnessPO Box 454Pompton Lakes NJ, 07442(800) [email protected]

Sample

0.072% D9-THC

1.990% Total CBD

Cannabinoids TestGSL SOP 400 PREPARED: 06/11/2019 21:38:31 UPLOADED: 06/12/2019 16:50:40 cannabinoids weight(%) mg/gDELTA-9-TETRAHYDROCANNABINOL D9-THC 0.072% 0.723TETRAHYDROCANNABINOLIC ACID THCA N/D N/DCANNABIDIOL CBD 1.962% 19.623CANNABIDIOLIC ACID CBDA 0.032% 0.321CANNABIDIVARIN CBDV 0.009% 0.091CANNABICHROMENE CBC 0.146% 1.456CANNABINOL CBN N/D N/DCANNABIGEROL CBG 0.042% 0.424CANNABIGEROLIC ACID CBGA N/D N/DDELTA-8-TETRAHYDROCANNABINOL D8-THC 0.003% 0.029TETRAHYDROCANNABIVARIN THCV N/D N/D

TOTAL D9-THC 0.072% 0.723TOTAL CBD* 1.990% 19.905TOTAL CANNABINOIDS 2.266% 22.667

NotesApproximately 618.8mg cannabinoids per 30mL

4001 SW 47th Avenue Suite 207Davie, FL [email protected]

Green Scientific Labs uses its best efforts to deliver high quality results and to verify that the data contained therein are based on sound scientific judgment and levels listed are guidelines only and all data wasreported based on standard laboratory procedures and deviations. However Green Scientific Labs makes no warranties or claims to that effect and further shall not be liable for any damage or misrepresentation thatmay result from the use or misuse of the data contained herein in any way. Further, Green Scientific Labs makes no claims regarding representations of the analyzed sample to the larger batch from which it wastaken. Data and information in this report are intended solely for the individual(s) for whom samples were submitted and as part of our strict confidentiality policy, Green Scientific Labs can only discuss results withthe original client of record.

Page 2: CERTIFICATE OF ANALYSIS€¦ · CERTIFICATE OF ANALYSIS Order #: 32172 Order Name: veré full spectrum Batch#: fw190429t500m Received: 06/11/2019 Completed: 06/18/2019 Veré Health

PESTICIDE ANALYSIS:GSL SOP 401 PREPARED: 06/11/2019 23:10:30 UPLOADED: 06/12/2019 21:26:03

N/D = Not Detected, A/LOQ = Above LOQ Level, B/LOQ = Below LOQ Level, B/LOD = Below LOD Level

CERTIFICATE OF ANALYSISOrder #: 32172Order Name: veré full spectrumBatch#: fw190429t500mReceived: 06/11/2019Completed: 06/18/2019

Veré Health & WellnessPO Box 454Pompton Lakes NJ, 07442(800) [email protected]

GCMS-MS - Shimadzu GCMS-TQ8040

Pesticide Action Level(ppm)

Results(ppm)

LOQ(ppm)

LOD(ppm)

CAPTAN 0.700 N/D 0.003 0.001CHLORDANE 0.100 N/D 0.003 0.001CHLORFENAPYR 0.100 N/D 0.003 0.001COUMAPHOS 0.100 N/D 0.003 0.001

Pesticide Action Level(ppm)

Results(ppm)

LOQ(ppm)

LOD(ppm)

CYFLUTHRIN 2.000 N/D 0.003 0.001CYPERMETHRIN 1.000 N/D 0.003 0.001PARATHION-METHYL 0.100 N/D 0.003 0.001PENTACHLORONITROBENZENE 0.100 N/D 0.003 0.001

LCMS-MS - Shimadzu LCMS-8060

Pesticide Action Level(ppm)

Results(ppm)

LOQ(ppm)

LOD(ppm)

ABAMECTIN B1A 0.100 N/D 0.003 0.001ACEPHATE 0.100 N/D 0.003 0.001ACEQUINOCYL 0.100 N/D 0.003 0.001ACETAMIPRID 0.100 N/D 0.003 0.001ALDICARB 0.100 N/D 0.003 0.001AZOXYSTROBIN 0.100 N/D 0.003 0.001BIFENAZATE 0.100 N/D 0.003 0.001BIFENTHRIN 3.000 N/D 0.003 0.001BOSCALID 0.100 N/D 0.003 0.001CARBARYL 0.500 N/D 0.003 0.001CARBOFURAN 0.100 N/D 0.003 0.001CHLORANTRANILIPROLE 10.000 N/D 0.003 0.001CHLORPYRIFOS 0.100 N/D 0.003 0.001CLOFENTEZINE 0.100 N/D 0.003 0.001DAMINOZIDE 0.100 N/D 0.003 0.001DIAZANON 0.100 N/D 0.003 0.001DICHLORVOS 0.100 N/D 0.003 0.001DIMETHOATE 0.100 N/D 0.003 0.001DIMETHOMORPH 2.000 N/D 0.003 0.001ETHOPROPHOS 0.100 N/D 0.003 0.001ETOFENPROX 0.100 N/D 0.003 0.001ETOXAZOLE 0.100 N/D 0.003 0.001FENHEXAMID 0.100 N/D 0.003 0.001FENOXYCARB 0.100 N/D 0.003 0.001FENPYROXIMATE 0.100 N/D 0.003 0.001FIPRONIL 0.100 N/D 0.003 0.001FLONICAMID 0.100 N/D 0.003 0.001FLUDIOXONIL 0.100 N/D 0.003 0.001HEXYTHIAZOX 0.100 N/D 0.003 0.001

Pesticide Action Level(ppm)

Results(ppm)

LOQ(ppm)

LOD(ppm)

IMAZALIL 0.100 N/D 0.003 0.001IMIDACLOPRID 5.000 N/D 0.003 0.001KRESOXIM-METHYL 0.100 N/D 0.003 0.001MALATHION 0.500 N/D 0.003 0.001METALAXYL 2.000 N/D 0.003 0.001METHIOCARB 0.100 N/D 0.003 0.001METHOMYL 1.000 N/D 0.003 0.001MEVINPHOS 0.100 N/D 0.003 0.001MYCLOBUTANIL 0.100 N/D 0.003 0.001NALED 0.100 N/D 0.003 0.001OXAMYL 0.500 N/D 0.003 0.001PACLOBUTRAZOL 0.100 N/D 0.003 0.001PERMETHRINS 0.500 N/D 0.003 0.001PHOSMET 0.100 N/D 0.003 0.001PIPERONYLBUTOXIDE

3.000 N/D 0.003 0.001

PRALLETHRIN 0.100 N/D 0.003 0.001PROPICONAZOLE 0.100 N/D 0.003 0.001PROPOXUR 0.100 N/D 0.003 0.001PYRETHRINS(PYRETHRIN I)

0.500 N/D 0.003 0.001

PYRIDABEN 0.100 N/D 0.003 0.001SPINETORAM 0.100 N/D 0.003 0.001SPINOSAD 0.100 N/D 0.003 0.001SPIROMESIFEN 0.100 N/D 0.003 0.001SPIROTETRAMAT 0.100 N/D 0.003 0.001SPIROXAMINE 0.100 N/D 0.003 0.001TEBUCONAZOLE 0.100 N/D 0.003 0.001THIACLOPRID 0.100 N/D 0.003 0.001THIAMETHOXAM 5.000 N/D 0.003 0.001TRIFLOXYSTROBIN 0.100 N/D 0.003 0.001

4001 SW 47th Avenue Suite 207Davie, FL [email protected]

Green Scientific Labs uses its best efforts to deliver high quality results and to verify that the data contained therein are based on sound scientific judgment and levels listed are guidelines only and all data wasreported based on standard laboratory procedures and deviations. However Green Scientific Labs makes no warranties or claims to that effect and further shall not be liable for any damage or misrepresentation thatmay result from the use or misuse of the data contained herein in any way. Further, Green Scientific Labs makes no claims regarding representations of the analyzed sample to the larger batch from which it wastaken. Data and information in this report are intended solely for the individual(s) for whom samples were submitted and as part of our strict confidentiality policy, Green Scientific Labs can only discuss results withthe original client of record.

Page 3: CERTIFICATE OF ANALYSIS€¦ · CERTIFICATE OF ANALYSIS Order #: 32172 Order Name: veré full spectrum Batch#: fw190429t500m Received: 06/11/2019 Completed: 06/18/2019 Veré Health

CERTIFICATE OF ANALYSISOrder #: 32172Order Name: veré full spectrumBatch#: fw190429t500mReceived: 06/11/2019Completed: 06/18/2019

Veré Health & WellnessPO Box 454Pompton Lakes NJ, 07442(800) [email protected]

RESIDUAL SOLVENTS:Headspace GCMS - Shimadzu GCMS QP2020 with HS20

GSL SOP 405Prepared: 06/11/2019 23:08:06 Uploaded: 06/12/2019 23:16:58

Residual Solvent Action Level (ppm) Results (ppm) LOQ (ppm) LOD (ppm)ACETONE 5,000 N/D 140 20ACETONITRILE 410 N/D 25 1BENZENE 1 N/D 1 0.5BUTANE 5,000 N/D 50 10CHLOROFORM 1 N/D 1 0.5DICHLOROETHANE 1 N/D 1 0.5DICHLOROMETHANE 1 N/D 1 0.5ETHANOL 5,000 N/D 140 20ETHYL ACETATE 5,000 N/D 140 20ETHYL ETHER 5,000 N/D 140 20ISOPROPYL ALCOHOL 5,000 N/D 140 20METHANOL 3,000 N/D 100 20N-HEPTANE 5,000 N/D 140 20N-HEXANE 290 N/D 18 10PENTANE 5,000 N/D 140 20PROPANE 5,000 N/D 20 1TOLUENE 890 N/D 53 1TRICHLOROETHENE 0 N/D 0 0XYLENES 2,170 B/LOQ 130 20

4001 SW 47th Avenue Suite 207Davie, FL [email protected]

Green Scientific Labs uses its best efforts to deliver high quality results and to verify that the data contained therein are based on sound scientific judgment and levels listed are guidelines only and all data wasreported based on standard laboratory procedures and deviations. However Green Scientific Labs makes no warranties or claims to that effect and further shall not be liable for any damage or misrepresentation thatmay result from the use or misuse of the data contained herein in any way. Further, Green Scientific Labs makes no claims regarding representations of the analyzed sample to the larger batch from which it wastaken. Data and information in this report are intended solely for the individual(s) for whom samples were submitted and as part of our strict confidentiality policy, Green Scientific Labs can only discuss results withthe original client of record.

Page 4: CERTIFICATE OF ANALYSIS€¦ · CERTIFICATE OF ANALYSIS Order #: 32172 Order Name: veré full spectrum Batch#: fw190429t500m Received: 06/11/2019 Completed: 06/18/2019 Veré Health

CERTIFICATE OF ANALYSISOrder #: 32172Order Name: veré full spectrumBatch#: fw190429t500mReceived: 06/11/2019Completed: 06/18/2019

Veré Health & WellnessPO Box 454Pompton Lakes NJ, 07442(800) [email protected]

Heavy Metals Analysis:ICP-MS - Shimadzu ICPMS-2030GSL SOP 403 Uploaded: 06/18/2019 02:02:52

Metal Action Level (ppb) Result (ppb)ARSENIC (AS) 200 B/LOQCADMIUM (CD) 200 B/LOQMERCURY (HG) 100 B/LOQLEAD (PB) 500 B/LOQ

Lower Limit of Quantitation (LOQ) is 75 ppb

Microbial Analysis:PCR - Agilent AriaMX

Microbial Analysis GSL SOP 406 Uploaded: 06/13/2019 17:12:42

Test Test MethodUsed Device Used LOD Allowable Amount Actual

Result Pass/Fail

STEC E.COLI* USP 61/62† ARIAMX PCR 2 COPIES OF DNA PRESENCE / ABSENT BELOW LOD PASS

SALMONELLA* USP 61/62† ARIAMX PCR 5 COPIES OF DNA PRESENCE / ABSENT BELOW LOD PASS

ASPERGILLUS USP 61/62† ARIAMX PCR ASP_LOD*** PRESENCE / ABSENT BELOW LOD PASS

YEAST AND MOLD USP 61/62† ARIAMX PCR 363.05518 CFU/G** 1,000BELOW

THRESHOLDPASS

TOTAL AEROBIC BACTERIA USP 61/62† ARIAMX PCR 0.25316 CFU/G** 10,000BELOW

THRESHOLDPASS

COLIFORM USP 61/62† ARIAMX PCR 3.41539 CFU/G** 100BELOW

THRESHOLDPASS

ENTEROBACTERIACEAE USP 61/62† ARIAMX PCR 0.32951 CFU/G** 100BELOW

THRESHOLDPASS

† USP 61 (enumeration of bacteria TAC, TYM, and ENT/Coliform), USP 62 (identifying specific species E.coli Aspergillus etc) * STEC and Salmonella run as Multiplex ** CFU/g Calculation based on Select Category Type Gummy MIP/Extract Flower matrix *** Flavus = 2 Copies of DNA / Fumigatis = 2 Copies of DNA Niger = 20 Copies of DNA / Terrus = 10 copies of DNA

4001 SW 47th Avenue Suite 207Davie, FL [email protected]

Green Scientific Labs uses its best efforts to deliver high quality results and to verify that the data contained therein are based on sound scientific judgment and levels listed are guidelines only and all data wasreported based on standard laboratory procedures and deviations. However Green Scientific Labs makes no warranties or claims to that effect and further shall not be liable for any damage or misrepresentation thatmay result from the use or misuse of the data contained herein in any way. Further, Green Scientific Labs makes no claims regarding representations of the analyzed sample to the larger batch from which it wastaken. Data and information in this report are intended solely for the individual(s) for whom samples were submitted and as part of our strict confidentiality policy, Green Scientific Labs can only discuss results withthe original client of record.