Upload
ngoquynh
View
221
Download
0
Embed Size (px)
Citation preview
EclipsE Panels with ClimaPlus Superior Performance/Donn Brand FinElinE Suspension System
Profile
Edge Detail
LEED CreditsRecycled Content: 95%
Waste Recycled Regional Rapidly Low-Emitting Daylight Acoustical Reduction Content Materials1 Renewable Materials and Views Performance Materials
MR EQ
DX® / DXL™
15/1615/16
Donn DX/DXL Suspension System/EclipsE Panels with ClimaPlus Performance
Features and Benefits– 15/16 exposed tee system. Components for
use in general and fire-rated applications.– Maximum economy and design simplicity.– DXL system features more than 80 UL designs
(up to 3 hours).– Cross-tee override ends resist twisting and give
a professionally finished look.– Meets or exceeds all national code requirements,
including seismic.– Patented Quick-RElEasE™ cross tees.– Custom colour available.
Applications– Fire-rated, interior
general use areas
Square Edge Shadowline Tapered
Shadowline Shadowline Beveled
Pedestals
Parchment 103 Manila 246 Beige 142 Straw 143 Sandstone 090 Taupe 107
Charcoal 534 Flat Black 205
Standard Colours
White
Squash 2661 Safari 2662 Redwood 566 Sienna 565 Halo 206 Mist 053 Nectar 546 Quartz 082
Advantage Colours
Silvertone 052 Breeze 2659 Blue Grey 564 Azure 2660 Slate 568 Spruce 567 Tuscany 2663 Sorbet 2658
Year Availability
192
Customer ServiceOntario/Atlantic Canada 800-387-2690Quebec/Eastern Ontario 800-361-1310Western Canada 800-242-4418
Web Sites: www.cgcinc.comwww.usgdesignstudio.com www.sustainableceilings.com www.seismicceilings.com
CGC Inc.350 Burnhamthorpe Rd. W., 5th FlMississauga, ON L5B 3J1
Safety First! Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment. Read MSDS and literature before specification and installation.
2009, CGC Inc.Printed in Canada
For information on trademarks refer to EAC_A377
EGR-OG58
Seismic Zones2 Seismic Solutions Rated Load 3
ASTM Class Length Height Item No. Class 4 Colour5 UBC IBC Categories 4 Hanger 5 Hanger 6 Hanger D, E, F Alternate Spacing Spacing Spacing6
Method
15/16 Tee System Main Tee Intermediate 12 1-1/2 DX/ Flat White 0-4 A-F 7/8 Moulding 12 lbs./LF 6.1 lbs./LF 3.6 lbs./LF
Duty 3600mm 38mm DXL247/ Standard ACM7 Clip
DX/DXL3600
Advantage
Heavy Duty 12 1-1/2 DX/ Flat White 0-4 A-F 7/8 Moulding 16 lbs./LF 7.3 lbs./LF 4.9 lbs./LF
DXL267
Standard ACM7 Clip
Advantage
Cross Tee 1 2 1 DX/ Flat White 0-4 A-F 7/8 Moulding
600mm 25mm DXL216/ Standard ACM7 Clip
DXL600
Advantage
Cross Tee 1-1/2 4 1-1/2 DX/ Flat White 0-4 A-F 7/8 Moulding
1200mm 38mm DXL424/ Standard ACM7 Clip
DXL1200
Advantage
DX4229 Class A Flat White 0-4 A-F 7/8 Moulding
Standard ACM7 Clip
Advantage
1 DX/ Class A Flat White 0-4 A-F 7/8 Moulding
25mm DX416/ Standard ACM7 Clip
DX1200
Advantage
5 1-1/2 DX/ Flat White 0-4 A-F 7/8 Moulding
1500mm 38mm DXL524/ Standard ACM7 Clip
DXL1500
Advantage
Wall Angle12 Length Item No. Colour Wall Angle 12 Length Item No. Colour
Moulding 10 10 M20SM-2 Flat White 12 or 10 M7 Flat White
Standard Standard
Advantage
Advantage
Shadowline11 10 MS2745 Flat White 10 M205 Flat White
2 shelf for seismic Standard M20HD Standard
Advantage Heavy Duty Advantage
M20SM
Seismic
7/8"
3/4"11/4"
9/32"
2"
2"
System meets or exceeds load compliance specifications per ASTM C635
7/8"
7/8"
Product literatureData sheet# EGR-OG58
MaterialDouble-web hot-dipped galvanized steel body; steel cap finished with four-step protective coating.
Recycled content25%. For details, see the Sustainability selector.
InstallationMust be installed in compliance with ASTM C636, CISCA or standard industry practices, within all applicable code requirements. See UL Fire Resistance Directory for rated assembly details.
LimitationsSevere Environmental Requirements: Panels in exposed grids in non-fire-
L.A. Research Report ComplianceDonn brand suspension systems manufactured by CGC Interiors, Inc., have been reviewed and are approved by listing in one or more of the following L.A. Research Report numbers: 22179, 23451, 24095.
The City of New York BSA and MEA Report ComplianceDonn suspension systems have been approved by listing in one or more of the following City of New York Board of Standards and Appeals, and Department of Building, Material and Equipment Acceptance reports: BSA 618-60-SM, BSA 184-77-SM, BSA 796-81-SM, MEA 366-93-M, MEA 133-95-M, MEA 312-99-M, MEA 123-00-M.
ASTM C635 Standard for Load ComplianceSystem meets or exceeds load compliance specifications per ASTM C635. Main tees will not deflect more than 1/8 over 48 span (or L/360) in Light Duty, Intermediate Duty or Heavy Duty categories.
Footnotes1. Dependent on location; contact your CGC representative.2. All DX/DXL main-tee and cross-tee connections meet IBC requirements for tension and compression strength.3. Load test data shows uniform load in lbs./LF based on simple span tests in accordance with ASTM C635 deflection limit of L/360. For detailing and module
loading, request AC269QRC.4. UL fire-rated listing, labeling and follow-up applies only to fire-rated components.5. Non-fire-rated only.6. Cross-tee hole punch spacings also available for 20 and 30 modules.7. Available in metric; add “ME” to Item No. Consult Customer Service for colours of metric tees.8. For mouldings information, see Perimeter Interface selector.9. Panels must be specified to be field-cut, field-revealed and to provide widest possible lay-on edge.10. For DXL, channel mouldings are also acceptable in some designs. Check UL Fire Resistance Directory for moulding options.
rated, high-humidity applications: use all-aluminum AX™ or ZXLA™ painted HDG suspension systems with aluminum cap. Panels in exposed grids in fire-rated, high-humidity applications: use ZXLA suspension systems. For all exterior applications, suspension should be reviewed by a structural engineer.
ICC Evaluation Service, Inc., Report ComplianceSuspension systems manufactured by CGC Interiors, Inc., have been reviewed and are approved by listing in ICC-ES Evaluation Reports. Evaluation Reports are subject to reexamination, revision and possible cancellation. Please refer to usgdesignstudio.com for current reports.
Physical Data/Footnotes
2"
1"
New Donn Seismic Solutions – Meets or exceeds all national code requirements with 7/8 wall moulding. – Fulfills requirements for IBC seismic design categories A-F.
– Certified with maximum sq. ft. weights, representing complete ceiling systems. – Compliance with IBC seismic design categories D, E, and F with CGC
Intermediate Duty system without perimeter wires.
193
Suspension Systems
Exposed 15/16 Face