593
Waste water lifting plant for waste water free of faeces
Available as single or double lifting plant ■
For the most diverse applications ■
With a polyethylene or stainless steel collector tank ■
With various pump types ■
Upgradable with diverse accessories ■
Waste water lifting plant for waste water containing faeces
Available as single or double lifting plant ■
For the most diverse applications ■
With a polyethylene or stainless steel collector tank ■
With various pump types ■
Upgradable with diverse accessories ■
593
14
K9/1
Waste water lifting plants
Pumps Waste water lifting plants
Chapter contents
Information
Basics . . . . . . . . . . . . . . . . . . . . . .594
Installation . . . . . . . . . . . . . . . . . . .596
594
14
K9/1
Lifting plantsPlanning references
Pumps Waste water lifting plants
Basics
Image 1: Protection against backflow at drops to the sewer through a waste water lifting plant in multi-family buildings, retail properties and single family dwellings with in-law units .
Image 2: Protection against backflow, if the sewer is located higher than the sanitary drainage objects
General information
According to the building regulations of the states, structures may only be erect-ed, if the waste water disposal is properly and permanently secured . Property areas, on which waste water accumulates, must be connected to the public sewer system, if it is operational . Only by this connec-tion enforcement, meaning through the direct connection of the property drainage with the public sewage system, does the backflow problem also develop in this area . Depending on the sewer type, separate or combined sewage system, a variance in the frequency of the backflow can be anticipated . Grey and rain water is discharged in separate pipe systems in a separate sewage system . Backflow thereby occurs less frequently in grey water drains due to a prohibited discharge of waste material, pipe clogging as well as through operation based measures in the sewer system, however, basically cannot be excluded . The physical effect of a sewer backflow is based on the principle of the communicat-ing pipes . Since the pipe systems of the property drainage are directly connected with the public sewer, the waste water enters the area of the property drainage via these pipes in the event of a backflow . The same water level develops here as in the public sewer . This means that the waste water leaks from all unsecured
openings, such as floor drains, toilets, etc . until the water levels are balanced . This results in a certain height for the backflow risk in property areas, for which special measures must be made against backflow within the property drainage . This height is called backflow level . The decisive backflow level is defined by the local authorities (local statutes) . If such a definition is missing, the height of the edge of the road above the connecting point of the property drainage pipe to the public sewage system applies as backflow level according to EN 12056-4 and DIN 1986-100 . Despite this, a backflow cannot be ruled out above this level, for example, due to a pipe obstruction . If a waste water backflow can penetrate into unprotected rooms within buildings, masonry and foundations are soaked . Water damages occur on furnishings . Health impairments via infectious diseases cannot be ruled out . Damages and the risk connected with a waste water backflow must therefore be kept as low as possible by a protection against backflow . The responsibility for this is generally that of the property owner according to the community waste water regulations . He can contract the proper experts, such as planners and installers for the planning and proper completion .
The maximum protection against backflow can be achieved by a waste water lifting plant by guiding its pressure line via the backflow level (image 1 and 2). The planning and dimensioning of waste water lifting plants is accomplished according to EN 12056-4 (valid from 01 .01 .2001) and the residual standard DIN 1986-100 (introduced in March 2002) . Since EN 12056 with residual standard DIN 1986-100 covers all waste water systems in the area including the build-ing's outer cover and DIN 1986-100also the area of the property up to the property boundary (EN 752 applies here from the building's outer cover to the sewer connection in Europe), when granting the contract, the standard according to which the waste water system must be planned and laid out must be defined .
595
14
K9/1
Lifting plantsPlanning references
Pumps Waste water lifting plants
Protection against backflow
DIN 1986-100 'drainage systems for build-ings and property" and EN 12056 "Grav-ity drainage systems inside buildings", stipulate that grey water that accumulates below the backflow level and rain water of surfaces below the backflow level must be returned to the public sewer system via an automatic lifting plant . The principle "accumulating surface water must be channelled away from the building and not penetrate the building" applies when
planning a drainage system . Accordingly, rain areas must be drained by separate pumping stations outside of the building . All drainage facilities located above the backflow level must be drained by natural drops (gravity principle); the waste water of these drainage facilities may not be drained via backflow stops and only via waste water lifting plants in exceptional cases (e .g . reconstruction) . If the respon-
sible authorities have not defined the backflow level, at least the height of the street to the connecting point applies as backflow level .
Medium
Waste water Any type of polluted waste water arising in the domestic and commercial sector is considered to be waste water . This includes rainwater, contaminated water through use, commercially used water, etc . Domestic sewage Domestic waste water is a mixture of drinking water, organic and inorganic substances in solid and dissolved form . The substances occurring in waste water from households according to experience is are mainly human faeces, hair, food waste, cleaning and washing agents, as well as various chemicals, paper, rags and sand (for example, in com-bined systems from rain water erosion . However, experience shows that all waste is initiated by ignorance or disregard,
and must then be discharged by sanitary drainage objects . The pH value gener-ally is between pH 6 .5 and pH 7 .5 (pH 7 = neutral) . Grey water Waste water free of faeces . Black water Waste water containing faeces . Surface water Untapped rainwater, which is only con-taminated by dirt on the drain surface by air pollution, contamination . The degree of contamination depends primarily on geography, urban proximity (air and land pollution) and frequency of rain . Impurities frequently contain oil, salt, or sand .
Industrial waste water (= water for industrial use) Industrial waste water requires a detailed analysis of the medium, since the chemi-cal constituents may vary greatly, becom-ing a threat to the installation . Corrosion damage can be observed here most frequently . Particular attention should be given to waste water from the textile and food industries . Impeller type (e .g ., blockage), shaft dimensions (due to highly different outflows) and a combination of materials (e .g . corrosion) of the installa-tion are the key critical points here .
596
14
K9/1
Lifting plantsPlanning references
Pumps Waste water lifting plants
Installation
Buoyancy safeguard
A buoyancy safeguard is an attachment of a system/ pump at the bottom (or at the pump shaft in the ground), in order to prevent floating during flooding (or an increased groundwater level) of the area , since damages may develop on connec-
tions/pipes that could result in a leakage of the medium . The buoyancy safeguard is located directly on containers, or is subsequently installed or is already cast . Attention should be paid that the system/ pump is located solid and stationary on
the underground and cannot begin to shift or turn .
Ventilation
Main ventilation Extension of a vertical sewage downpipe whose end is open towards the atmos-phere above the last connecting line or the last connection . Secondary ventilation line Vertical vent pipe, which is connected to a waste water downpipe, to limit the pressure fluctuations within the waste
water downpipe . Venting the lifting plants must be completed in accordance with EN 12056-1 over the roof . The vent pipe may be introduced into both the main and the secondary ventilation . The ventilation of lifting plants may not be combined with the ventilation of a grease separator on the inflow side . A minimum cross-section of DN 70, or better DN 100, must be provided for faeces lifting
plants according to EN 12056-1 . Pres-sure relief valves are not permitted for lifting plants according to DIN 1986-100 .
Inlet
The inlet pipe into the waste water lifting plant may not be reduced in the flow direc-tion . A stop valve must be arranged on the inlet side (based on the replacement
options of the system or for repair or maintenance work)
The drainage pipes must be connected to the lifting plant . The weight of the pipes or fittings must be handled accordingly on-site .
Pressure line
Backflow level
Highest point in an installation to which the contaminated water can rise . The backflow level is located in the area of greatest cross-sectional expansion . Instal-lations should be designed so that the water from the drains cannot return to the pumping station . This could occur during storms, floods and heavy rainfall, if the municipal sewage system is not designed for such volumes . Damages that result hereby, are not covered by insurance
and are only successfully enforceable in rare cases . A coverage is the choice of the operator / owner . Information on the height of the backflow level is defined in the local statutes .
Backflow loop
A backflow loop represents an artificially elevated pipe run above the backflow level, so that backflow water can first distribute over all low lying open spaces . Since it can be assumed that a sufficient volume is available in the entire pipeline, the backflow loop presents the safest alternative against backflow. The liability is with the processor or planner when the backflow safety valve is missing .
Sound insulation
Suitable measures (wall openings, low-noise valves, flow velocity) must be implemented in installations from the beginning, in order to minimize the noise
burden . This is also based on the fact that a subsequent modification is associated with high costs and designates a value
reduction of the entire area . DIN 4109 is a guideline for this .
Pressure line connection
The connection of the pressure pipe is made on the base and collection line . Suit-able pressure pipes, which can withstand the pressure of 1 .5 times of the maximum pump pressure of the system, must be used .
The dimensioning of the basic line after being discharged into the discharge pipe is regulated in EN 12056-2 and EN 12056-3 . In general, it appears that the basic line before reaching the pressure
line must be selected one nominal diam-eter larger . Sanitary drainage objects may not be connected to the pressure line . It may also not be connected to grey water downpipes .
597
14
K9/1
Lifting plantsPlanning references
Pumps Waste water lifting plants
Installation premises
A pump sump must be arranged for drain-ing the set-up area . This can be drained by means of an automatic drainage pump in the pressure line of the lifting plant, behind the backflow loop .
The set-up area of the waste water lifting plant must be sufficiently ventilated to prevent condensation; it must also be sufficiently large so that a work area of at least 60 cm in width and height is
available, next to and above all parts to be maintained . Adequate lighting must be available
Container
Collector tanks of faeces lifting plants must have an effective volume of 20 l , be waterproof and odour-sealed . They are considered as explosion endangered areas, as on-site shafts . The explosion protection regulations according to DIN
/ EC Directive 94/9/EC ATEX must be observed . Collecting tanks of faecal lifting plants may not be structurally connected to the building . Surface water which accumulates outside
the building below the backflow level, must be delivered by a waste water lifting plant/pump separately from domestic waste water and outside the building .
Usable volume
The volume between the power on and power off point of the pump is generally described as usable volume - also called required storage volume . In special cases, where the intake to the pumping station is located below the power on point of the pump and is therefore stored, the intake volume can be used to cover the required storage volume . It must be replaced at every pumping process, i .e . usable
volume > pressure line volume . Systems that prevent the penetration of materials and liquids into the waste water lifting plant, which extend hazardous or nuisance vapours or odours, which affect the materials in the waste water systems or interfere with the operation, must be arranged in beforehand . Such systems include: Oil and gasoline according to EN 858 /DIN 1999-100, light liquids closures
under DIN 4043, emulsion splitting plants, grease separators in accordance with EN 1825/DIN 4040-100, starch separators according to factory standards, sand and sludge traps as well as neutralization plants .
Electric installation
The electrical installation must be per-formed by a professional . Switching and signalling devices must be installed in a
dry, accessible location . The signalling system must also be attached at an easily noticeable location .
Dimensioning
The layout and dimensioning of the pumps is carried out in accordance with EN 12056-4 . Here, the total delivery height and total inflow are determined . A pump must be selected for the values that reaches at least the delivery height and the delivery capacity determined in its operating point (taking into account the minimum flow velocity of 0 .7 m / s, max . 2 .3 m / s) . In tank systems, it is important to guar-antee that the useful tank volume (volume between the power on and off point) is greater than the volume in the pressure line
(above the backflow prevention up to the backflow loop) . This will ensure that the content of the pressure line is completely exchanged per pumping process to pre-vent anaerobic digestion processes . When calculating the useful volume, the following instructions should be followed: Pumps or lifting plants are usually de-signed for the S3 (intermittent operation), i .e . a sufficient downtime of the pump (to cool the motor) must be available after completing the pumping process after switching on the pump . This results in the following guidelines:
Motor capacity
[kW]
Air-cooled 1500 [rpm]
Air-cooled 2900 [rpm]
Up to 1 .5 80 40Up to 3 .0 45 23Up to 7 .5 30 15Up to 11 15 8More than 11 10 5
Minimum run time for submerged pumps
Motor capacity
[kW]
Submerged pump, half submerged mini-mum run time in sec
Up to 4 120Up to 7 .5 145From 7 .5 180
598
14
K9/1
Lifting plantsPlanning references
Pumps Waste water lifting plants
Types of impellers
When selecting the impeller, verify which design is best for the particular use .
Channel impeller
The channel impeller is suitable for deliver-ing grey water containing faeces, as well as delivering waste water with
solid and short fibrous solid and viscous products, sludge and organic materials .
Free flow impeller
A large open chamber in the pump hous-ing (free ball passage) makes it possible that the liquid flows easily over the suction opening into the pump chamber and solid and long-fibre viscous products flowing, such as long bandages, fabrics, etc ., can easily pass through without clogging the pump housing .
Another advantage: since no throttle gap is present between the impeller and the pump housing of free flow pumps, this design allows a great operational reli-ability in applications with very extensive downtimes . Corroding the impeller and therefore a blockage of the pump is thereby excluded .
Cutting mechanism
Particularly suitable for long fibres with solids of a greater magnitude that can be disintegrated . For reliable transport of delivered material through small pressure lines on even long distances .
For the waste water disposal in even unfavourable terrain with large height differences .
599
14
K9/1
Lifting plantsPlanning references
Pumps Waste water lifting plants
Planning - procedure
Clarification of preliminary conditions
Installation premises
in the building ■
outdoors underground ■
(Load class A, B or D) ■
Backflow level ■
Conveyance media ■
Intake conditions into the sewer ■
Conveyance height and pipe routing ■
(distance to the sewer)
Current / voltage supply
230/400 V ■
Power frequency 50 Hz ■
Standard
EN 12050 ■
DIN 1986-100 ■
EN 12056 ■
EN 752 ■
EN 1610 ■
ATV-DVWK ■
Local Policy ■
Dimensioning of the plant
Waste water inflow (connection data) ■
Overall conveying height ■
Calculation of the pump operating point ■
Selection of the nominal pressure line ■
widthSelection of the required valves and ■
fittings
Checking the minimum flow velocity ■
Calculating the usable tank volume ■
Shaft designation ■
Standard
EN 12056-4 ■
EN 752 ■
ATV ■
Selecting the plant
Selection of the pump or lifting plant ■
Selection of control systems and acces- ■
soriesSingle or twin system ■
Explosion protected model ■
Definition of the pressure pipe, ■
vent pipe ■
Page
Waste water lifting plant – under-ground installation
Sinkamat series
Sinkamat-S 602
Sinkamat-Z 604
Sinkamat-K 606
Accessories 608
Waste water lifting plant for free-standing installa-tion
Sinkamat seriesSinkamat-K 610
Accessories 612
Muli-Series
Muli-Mini mono 614
Muli-Mini duo 616
Accessories 618
Pumps Waste water lifting plants Waste water free of faeces
601601
Page
Waste water lifting plant – under-ground installation
Sinkamat series
Sinkamat-S 602
Sinkamat-Z 604
Sinkamat-K 606
Accessories 608
Waste water lifting plant for free-standing installa-tion
Sinkamat seriesSinkamat-K 610
Accessories 612
Muli-Series
Muli-Mini mono 614
Muli-Mini duo 616
Accessories 618
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er f
ree
of
faec
es
14
K9/1
Waste water lifting plant for waste water free of faeces
Pumps Waste water lifting plants Waste water free of faeces
Section contents
602
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er f
ree
of
faec
es
14
K9/1
Waste water lifting plant – under-ground installationSinkamat series
Pumps Waste water lifting plants Waste water free of faeces
Sinkamat-S
Product information
ACO product advantages
With high-quality stainless steel man- ■
hole coverWith integrated acoustic signaller ■
With separate sediment collection ■
chamber for increased lifespanNo ventilation line required ■
Area of application ■
For underground installation in frost- �
protected rooms below the backflow level, e .g . basement, hobby rooms and laundry roomsFor domestic grey water free of fae- �
ces from showers, wash stands etc .Stainless steel cabinet, material grade ■
304
Stainless steel cover with hole pattern ■
Lateral inlet openings, choice of DN 50, ■
DN 70 or DN 100Connection ports DN 50 (plastic) for ■
conduitPressure pipe connection ■
R 1 � ¼“ for threaded pipeDN 50 for SML pipe �
Grey water immersion pump with heavy- ■
duty AC motorStainless steel motor housing and shaft ■
Plastic pump housing and impeller ■
With 5 m connecting cable and angled ■
safety plugWith magnetic float switch for low ■
activation heightsWith integrated check valve R 1 ■ ¼“
Ordering information
OFF
ON
ON/ alarm signal + autostart
OFF
sediment collection chamber
inlet
angled safety plug withmanual / auto selectionand signal installation(intermittent)
alarm contact
removableinlet - guiding plate
separable cablecoupling
tube angleR 1 ¼
pressure pipe R 1 ¼and DN 50 / SML
connection DN 50 / platic empty cable conduitand air ventilation
inlet left
inlet right
inle
t mid
dle
127
260
ca.7
0
145
387 x 296
180 136
432
ca.587
341
ca.4
96
120
156
460
75
case withconnection rim
case withconnection rim
inlet socket of stainless steelfor SML attachment
DN 50 DN 70 DN 100
OFF
ON
ON/ alarm signal + autostart
OFF
sediment collectionchamber
inlet
angled safety plug withmanual / auto selectionand signal installation(intermittent)
alarm contact
removableInlet - guiding plate
separable cable-coupling
tube angleR 1 ¼
pressure pipe R 1 ¼and DN 50 / SML
inlet left
inlet right
inle
t mid
dle
127
260
ca.7
0
145
387 x 296
180 136
432
ca.480
341
ca.3
76
120
156
460
connection DN 50 / plastic empty cable conduitand air ventilation
Construction with connection rim Construction without connection rim
603
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er f
ree
of
faec
es
14
K9/1
Waste water lifting plant – under-ground installationSinkamat series
Pumps Waste water lifting plants Waste water free of faeces
Remark: Maximum temperature of wastewater is only allowed for a short time .
Infobox
Type Description Motor rating Current con-
sumpti-on
Voltage Revolu-tions
Grain size
Weight Article No.
P1 P2[kW] [kW] [A] [V] [U/min] [mm] [kg]
50/1-S With connecting ■
rim 0,43 0,21 2,1 230 2800 10 26 0159.03.47
50/2-S With connecting ■
rim 0,65 0,38 3,1 230 2800 10 26 0159.03.51
50/1-S Without connec- ■
ting rim 0,43 0,21 2,1 230 2800 10 21 0159.03.45
50/2-S Without connec- ■
ting rim 0,65 0,38 3,1 230 2800 10 21 0159.03.49
Performance parameters
5,50,5 1,5
Min
dest
förd
erst
rom
DN
40
Min
dest
förd
erst
rom
DN
32
Min
dest
förd
erst
rom
DN
50
Leistungsdiagramm
n = 2800 U/min
Toleranzen ISO 2548/C12
11
10
6
2
4
0
8
20181614121086420
0 52,51 2 3 4,543,5
[m³/h]
[l/s]
Ges
amtfö
rder
höhe
H
Förderstrom Q
1
3
5
7
9
[m]
SINKAMAT 50/2 S
SINKAMAT 50/1 S
Type Delivery head
Delivery flow Q with total delivery head H Conveyance media temperature
2 m 3 m 4 m 5 m 6 m 7 m 8 m Normal Maxi-mum
[m] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]50/1-S 2 – 6 3,38 2,91 2,36 1,72 0,97 40 9050/2-S 2 – 8 4,44 4,02 3,61 3,11 2,5 1,94 1,19 40 90
604
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er f
ree
of
faec
es
14
K9/1
Waste water lifting plant – under-ground installationSinkamat series
Pumps Waste water lifting plants Waste water free of faeces
Remark: Other version (for example: double system) on request .
Infobox
Sinkamat-Z
Product information
ACO product advantages
With high-quality stainless steel man- ■
hole coverWith separate sediment collection ■
chamber for increased lifespanNo ventilation line required ■
Area of application ■
For underground installation in frost- �
protected rooms below the backflow level, e .g . basement, hobby rooms and laundry roomsFor domestic grey water free of fae- �
ces from showers, wash stands etc .Stainless steel cabinet, material grade ■
304
Stainless steel cover with hole pattern ■
Lateral inlet openings, choice of DN 50, ■
DN 70 or DN 100Connection ports DN 50 (plastic) for ■
conduitPressure pipe connection ■
R 1 � ¼“ for threaded pipeDN 50 for SML pipe �
Grey water immersion pump with heavy- ■
duty AC motorStainless steel motor housing and shaft ■
Plastic pump housing and impeller ■
Pump housing seal for the motor via a ■
mechanical sealWith 10 m safety plug ■
With ball float switch ■
With integrated check valve R 1 ■ ¼“
Ordering information
OFF
ON
sediment collection chamber
inlet
removable inlet - guiding plate
pressure pipe R 1 ¼and DN 50 / SML
connection DN 50 / plastic empty cable conduit and air ventilation
inlet left
inlet right
inle
t mid
dle
460
156
127
ca.
100 17
0
387 x 296
180 136
432
ca.587
341
ca.4
96
safety plug 230 V / 50 Hz
10 m cable
75
case with connection rim
120
case with connection rim
inlet socket of stainless steelfor SML-attachment
DN 50 DN 70 DN 100
connection DN 50 / plastic empty cable conduit and air ventilation
inlet left
inlet right
inle
t mid
dle
180 136
432
ca.480
341
ca.3
76
120
OFF
ON
sediment collection chamber
inlet
removable inlet - guiding plate
pressure pipe R 1 ¼and DN 50 / SML
460
156
127
ca.
100 17
0
387 x 296
safety plug 230 V / 50 Hz
10 m cable
Construction with connection rim Construction without connection rim
605
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er f
ree
of
faec
es
14
K9/1
Waste water lifting plant – under-ground installationSinkamat series
Pumps Waste water lifting plants Waste water free of faeces
Remark: Maximum temperature of wastewater is only allowed for a short time .
Infobox
Type Description Motor rating Current consump-
tion
Voltage Revolu-tions
Grain size
Weight Article No.
P1 P2[kW] [kW] [A] [V] [U/min] [mm] [kg]
50/1-Z Without connec- ■
ting rim 0,35 0,2 1,8 230 2800 10 26 0175.07.97
50/2-Z Without connec- ■
ting rim 0,65 0,35 3,5 230 2800 10 26 0175.08.45
50/1-Z With connecting ■
rim 0,35 0,2 1,8 230 2800 10 21 0175.07.98
50/2-Z With connecting ■
rim 0,65 0,35 3,5 230 2800 10 21 0175.08.46
Performance parameters
SINKAMAT 50/2 Z
SINKAMAT 50/1 Z
5,50,5 1,5
Min
dest
förd
erst
rom
DN
40
Min
dest
förd
erst
rom
DN
32
Min
dest
förd
erst
rom
DN
50
Leistungsdiagramm
n = 2800 U/min
Toleranzen ISO 2548/C12
11
10
6
2
4
0
8
20181614121086420
0 52,51 2 3 4,543,5
[m³/h]
[l/s]
Ges
amtfö
rder
höhe
H
Förderstrom Q
1
3
5
7
9
[m]
Type Deli-very head
Delivery flow Q with total delivery head H Conveyance media tempe-
rature2 m 3 m 4 m 5 m 6 m 7 m 8 m 9 m 10 m Normal Maxi-
mum[m] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]
50/1-Z 2 – 6 2,22 1,94 1,66 1,32 0,92 40 9050/2-Z 2 – 10 4,82 4,58 4,28 3,97 3,58 3,15 2,64 2,05 1,41 40 90
606
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er f
ree
of
faec
es
14
K9/1
Waste water lifting plant – under-ground installationSinkamat series
Pumps Waste water lifting plants Waste water free of faeces
Sinkamat-K
Product information
ACO product advantages
Quick coupler for fitting/removal of ■
the pump without toolsOptional waterproof concrete sealing ■
possibleMultiple connection possibilities ■
Top section with frame dimensions ■
198 x 198 mm or 360 x 300 mm (telescopic height adjustability)Optional manhole cover for selectable ■
surface and odour seal
Areas of application ■
For underground installation in frost- �
protected rooms below the backflow level, e .g . basement, hobby rooms and laundry roomsFor domestic grey water free of fae- �
ces from showers, wash stands etc .
Certified in accordance with ■
EN 12050-2Polyethylene cabinet ■
Useable volume: 15 l ■
With 3 inlet sockets DN 100 ■
With height-adjustable top sections ■
Stainless steel motor housing and shaft ■
Plastic pump housing and impeller ■
Pump housing seal for the motor via a ■
mechanical sealWith 10 m connecting cable and safety ■
plugWith ball float switch ■
With integrated check valve R 1 ■ ¼“Pressure pipe connection in accordance ■
with EN ISO 15493PVC-U; 50-40-R 1 � ¼“
Ordering information
PVC-U pressure pipewith integratedcheck valve
WU-concretesealing ring(optional)
H m
in. 6
04
PV
C-U
158
443
270
3737
565
H m
ax. 6
75
30
ventilationDN 50
Ø430
670Ø520replacement pump
50/1 Z m. 10 m cable/Z.Sinkamat Ø75
335
cable glandinletDN 100
inletDN 100
Sinkamat-K (Article No. 620441)
300
360
Sinkamat-K (Article No. 620387)
Ø75
670Ø520
Ø430
541
585
158
443PV
C-U
Inlet DN 50
335
cable gland
inletDN 100
inletDN 100
27037
37 □
198
PVC-U pressure pipewith integratedcheck valve
replacementpump 50/1 Z m. 10 m cable/Z.Sinkamat
WU-concretesealing ring(optional)
PVC-U pressure pipewith integratedcheck valve
443
H m
in. 6
04
565
H m
ax. 6
75
PV
C-U
ventilationDN 50
replacementpump 50/1 Z m. 10 m cable/Z.Sinkamat
WU-concretesealing ring(optional)
Ø430
158
30
27037
37
670Ø520
cable glandinlet DN 100
335
360
300
150
inletDN 100
Sinkamat-K (Article No. 620442)
Ø75
50
607
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er f
ree
of
faec
es
14
K9/1
Waste water lifting plant – under-ground installationSinkamat series
Pumps Waste water lifting plants Waste water free of faeces
Remark: Maximum temperature of wastewater is only allowed for a short time .
Infobox
Type Top section Motor rating Current con-
sumpti-on
Voltage Revolu-tions
Grain size
Weight Article No.
P1 P2[kW] [kW] [A] [V] [U/min] [mm] [kg]
50/1-K
Frame dimensions: ■
360 x 300 mmReversible cover ■
plate, load class K3
0,35 0,2 1,8 220 2800 10 23 620441
50/1-K
Frame dimensions: ■
198 x 198 mmSlotted grating, load ■
class K3
0,35 0,2 1,8 220 2800 10 23 620387
50/1-K
Frame dimensions: ■
360 x 300 mmManhole cover for ■
selectable surfaceWith odour seal ■
With slotted grating ■
Frame di- �mensions: 150 x 150 mmLoad class: K3 �
0,35 0,2 1,8 220 2800 10 23 620442
Performance parameters
Toleranzen ISO 2548 / C
n = 2800 1 / min
0 0,5 1 1,5 2 2,5 30
1
2
3
4
5
6
7
8
Min
dest
förd
erst
rom
DN
50
Min
dest
förd
erst
rom
DN
40
Min
dest
förd
erst
rom
DN
32
0 2 4 6 8 101 3 5 7 9
Ges
amtfö
rder
höhe
H
[m]
[m³/h][l/s]
Förderstrom Q
Type Delivery head
Delivery flow Q with total delivery head H Conveyance media temperature
2 m 3 m 4 m 5 m 6 m Normal Maximum[m] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]
50/1-K 2 – 6 2,22 1,94 1,66 1,32 0,92 40 90
608
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er f
ree
of
faec
es
14
K9/1
Waste water lifting plant – under-ground installationSinkamat series
Pumps Waste water lifting plants Waste water free of faeces
Accessories
Designation compatible with Description Article No.
200
427 x 336387 x 296
432 x 341
Top section Sinkamat-S/Z ■
Stainless steel, material grade ■
304Without connecting rim ■
Height: 200 mm ■
For larger installation depths ■
0159.03.4220
0
460 x 369
427 x 336387 x 296
Top section Sinkamat-S/Z ■
Stainless steel, material grade ■
304Without connecting rim ■
Height: 200 mm ■
For gas and odour-tight design ■
0175.20.73
587 x 496
7520
0
427 x 336387 x 296
432 x 341
Top section Sinkamat-S/Z ■
Stainless steel, material grade ■
304With connecting rim ■
Height: 200 mm ■
For larger installation depths ■
0159.03.43
587 x 496
200
460 x 369
75
427 x 336387 x 296
Top section Sinkamat-S/Z ■
Stainless steel, material grade ■
304With connecting rim ■
Height: 200 mm ■
For gas and odour-tight design ■
0159.03.44
Cover Sinkamat-S/Z ■
Stainless steel, material grade ■
304With profile packing ■
Sealed to gas and odour ■
Screwed in place ■
Fitted with container aeration ■
0159.38.82
Pickup Sinkamat-S/Z ■
With 10 m cable ■
For a separate signal device/ ■
dry contact for fault signal level0159.12.46
Hupe„AUS“
Störung
Test
Summer
116 (60 T)
116
Signal device (network dependent)
Automatic faeces backflow ■
systems Quatrix-K Type 3FSinkamat-S/-Z ■
Muli polyethylene duo ■
Muli polyethylene S mono/duo ■
All Multi-Pro waste water lifting ■
plantsSuspension plant mono/duo ■
Visual and acoustic ■
Network dependent ■
Without pickup ■
With dry contact for fault signal ■
levelWith 1 m connecting cable and ■
angled three-wire plug
0159.12.30
Hupe„AUS“
Störung
Test
Summer
116 (60 T)
116
Signal device (network independent)
Automatic faeces backflow ■
systems Quatrix-K Type 3FSinkamat-S/-Z ■
Muli polyethylene S mono/duo ■
All Multi-Pro waste water lifting ■
plantsSuspension plant mono/duo ■
Visual and acoustic ■
Self-charging ■
Without pickup ■
With dry contact for fault signal ■
levelWith acoustic deletion ■
With 1 m connecting cable and ■
angled three-wire plug
0159.12.31
DN50
52
Inlet socket Sinkamat-S/Z ■
Stainless steel, material grade ■
304DN 50 ■
0159.03.37
DN70
52
Inlet socket Sinkamat-S/Z ■
Stainless steel, material grade ■
304DN 70 ■
0159.03.36
609
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er f
ree
of
faec
es
14
K9/1
Waste water lifting plant for free-standing installationSinkamat series
Pumps Waste water lifting plants Waste water free of faeces
Designation compatible with Description Article No.DN100
52
Inlet socket Sinkamat-S/Z ■
Stainless steel, material grade ■
304DN 100 ■
0159.03.35
Ø676
Sealing flange
Backflow stops and Cleaning ■
pipes for installation in the base plateSinkamat-K (underground) ■
For installation in waterproof ■
concreteMaximum groundwater level: �3 m
620382
349
289
30
Cover plate complete Sinkamat-K (underground) ■
Manhole cover for selectable ■
surfaceWith slotted grating ■
Frame dimensions: �150 x 150 mmLoad class: K 3 �
With odour seal ■
Water trap: 50 mm �
620385
610
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er f
ree
of
faec
es
14
K9/1
Waste water lifting plant for free-standing installationSinkamat series
Pumps Waste water lifting plants Waste water free of faeces
Sinkamat-K – polyethylene small lifting plant for above-ground installation
Product information
ACO product advantages
Quick coupler for fitting/removal of ■
the pump without toolsMinimal installation dimensions via ■
innovative designMaintenance without dismantling the ■
inlet-side siphon
Area of application: ■
For above-ground installation in frost- �
protected rooms below the backflow level, e .g . basement, hobby rooms and laundry roomsFor domestic grey water free of �
faeces from showers or wash stands etc .
Certified in accordance with ■
EN 12050-2
Polyethylene container ■
With multiple connection possibilities up ■
to DN 50With forward-facing inspection opening ■
Container aeration via activated carbon ■
filterGrey water immersion pump with heavy- ■
duty AC motorStainless steel motor housing and shaft ■
Plastic pump housing and impeller ■
Pump housing seal for the motor via a ■
mechanical sealWith 10 m connecting cable and safety ■
plugWith ball float switch ■
With integrated check valve R 1 ■ ¼“Pressure pipe connection in accordance ■
with EN ISO 15493PVC-U, 50-40-R 1 � ¼“
Ordering information
329
pump 50/1-Zwithout grip for Sinkamat ÜF made of plastic
416
332
PVC-U connectionpressure pipe withintegrated check valve
611
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er f
ree
of
faec
es
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water free of faeces
Remark: Maximum temperature of wastewater is only allowed for a short time .
Infobox
Type Motor ra-ting
Current con-sumption
Voltage Revolutions Grain size Article No.
P1 P2[kW] [kW] [A] [V] [U/min] [mm]
50/1-Z 0,35 0,2 1,8 220 2800 10 620386
Performance parameters
Toleranzen ISO 2548 / C
n = 2800 1 / min
0 0,5 1 1,5 2 2,5 30
1
2
3
4
5
6
7
8
Min
dest
förd
erst
rom
DN
50
Min
dest
förd
erst
rom
DN
40
Min
dest
förd
erst
rom
DN
32
0 2 4 6 8 101 3 5 7 9
Ges
amtfö
rder
höhe
H[m]
[m³/h][l/s]
Förderstrom Q
Type Delivery head Delivery flow Q with total delivery head H Conveyance media temperature2 m 4 m 6 m Normal Maximum
[m] [l/s] [l/s] [l/s] [°C] [°C]50/1-Z 2 – 6 2,22 1,66 0,92 40 90
612
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er f
ree
of
faec
es
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water free of faeces
Accessories
Designation compatible with Description Article No.
Ø65
66Ø69Ø58
Inlet socket DN 50
Cellar drain Junior with back- ■
flow stopCellar drain DN 100 ■
Sinkamat-K (free-standing ■
installation)
Plastic ■
For lateral inlet ■
Customer-side fitting ■
Weight: 0 .1 kg ■
2410.00.04
Ø43
Keyhole saw Sinkamat-K (free-standing ■
installation)
Bimetal hole saw suitable for ■
Plastic �Thin materials �
0150.14.80
Adapter Keyhole saw ■
0150 .14 .80 �
Intake with HSS drill for hole ■
sawDiameter: 32 – 110 mm �
0150.14.81
613
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er f
ree
of
faec
es
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water free of faeces
614
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er f
ree
of
faec
es
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water free of faeces
Muli-Mini mono
Product information
ACO product advantages
Pneumatic level control with air bubble ■
injection for increased operating securityMinimal wear via a high useable ■
volumeOptimal access to the operating ■
elementsQuick and safe fitting of the pressure ■
pipe via special mounting piece
Areas of application ■
Laundry rooms �
Warehouse �
Basements �
Polyethylene collector tank ■
With drain plug ■
With mounting set for buoyancy safety ■
anchoringWith 1 horizontal and 1 vertical inlet ■
socket DN 100
With ventilation connection DN 70 for ■
connection to the plastic pipePressure pipe connection ■
1 ball check valve R 2“, with stainless �
steel pipe material grade 3161 ball valve R 2“ and special moun- �
ting piece DN 50 for elastic con-nection of the pressure pipe with an external diameter of 57 – 61 mm
Grey water immersion pump ■
With three-phase current immersion �
motorProtection category IP 68 �
With lock ring/circular seal ring �
With blockage-free free flow impeller �
Switching and warning device ■
Protection category IP 54 �
With 1 .5 m cable and CEE plug �
With dry contact centralised fault �
signal and operating signalInc . 4 m pneumatic control line bet- �
ween the lifting plant and control box
Ordering information
inletDN100
inletDN100
drain plug
flaps forbuoyancy control pneumatic control
free flow pumpgrain size 38 mm
as option:additionally inlet socket DN50
ball valve R 2"
special fastening pieceDN 50 (from Ø57 -Ø61 mm)
ball retaining valve
ventilation DN70
waste water collecting tankmade of polyethylene
pitot tube
625
min
.250 max
.450
Ø50
5545
0 (Z
1)
Ø640
245
180
280
70
ca. 1
220
70
Ø57-61
mini compressorfor air bubble injection
connectionpneumaticcontrol cable(4 m long)
switch box plug-in ready(250 x 195 x 100)
connectioncentralised fault signal(4m long) motor cable
(4 m long)
electr. connection formini compressor
cable1.5 m long withCEKON-connector 16 A
ACO
615
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er f
ree
of
faec
es
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water free of faeces
Remark: Maximum temperature of wastewater is only allowed for a short time .
Infobox
Type Motor ra-ting
Current con-
sumpti-on
Voltage Revolu-tions
Grain size
Total volume
Useable volume Weight Article No.
P1 P2 Inlet height
Z1
Inlet from above
[kW] [kW] [A] [V] [U/min]
[mm] [l] [l] [l] [kg]
Muli-Mini V 75-mono 1,3 0,55 1,3 400 2900 35 150 75 90 65 0175.08.40
Muli-Mini V 150-mono 2,5 1,1 2,5 400 2900 38 150 75 90 70 0175.08.41
Performance parameters
MULI-MINI-V 75
Min
dest
förd
erst
rom
DN
65/
70
Min
dest
förd
erst
rom
DN
50
MULI-MINI-V 150
Toleranzen ISO 2548/C
n = 2900 U/min
1512963 36333027242118
4321 10987650
2
4
6
8
10
12
14
16
Ges
amtfö
rder
höhe
H
[m]
[m³/h]
[l/s]
Förderstrom Q
Type Delivery head
Delivery flow Q with total delivery head H Conveyance media temperature
2 m 4 m 6 m 8 m 10 m 12 m Normal Maxi-mum
[m] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]Muli-Mini V 75-mono 2 – 7 6,2 4,0 2,0 40 60
Muli-Mini V 150-mono 2 – 12 9,3 7,7 6,2 4,8 3,3 1,8 40 60
616
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er f
ree
of
faec
es
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water free of faeces
Muli-Mini duo
Product information
ACO product advantages
Pneumatic level control with air bubble ■
injection for increased operating securityMinimal wear via a high useable ■
volumeOptimal access to the operating ■
elementsFast and safe fitting via special moun- ■
ting piece
Areas of application ■
Grease separator up to NS 4 �
Laundry rooms �
Basements �
Polyethylene collector tank ■
With drain plug ■
With mounting set for buoyancy safety ■
anchoringEach with 1 horizontal and 1 vertical ■
inlet socket DN 100With ventilation connection DN 70 for ■
connection to the plastic pipe
Pressure pipe connection ■
2 ball check valves R 2“ �
Stainless steel Y-branch pipe, materi- �
al grade 3041 ball valve R 2“ and special moun- �
ting piece DN 50 for elastic con-nection of the pressure pipe with an external diameter of 57 – 61 mm
2 grey water immersion pumps ■
With three-phase current immersion �
motor - version DWith AC immersion motor - version W �
Protection category IP 68 �
With lock ring/circular seal ring �
With blockage-free free flow impeller �
Switching and warning device ■
Protection category IP 54 �
With 1 .5 m cable and CEE plug �
With dry contact centralised fault �
signal and operating signalInc . 4 m pneumatic control line bet- �
ween the lifting plant and control box
Ordering information
ball valve R 2"
special fastening pieceDN 50 (from Ø57 -Ø61 mm)
common pressure pipe R 2"
ball retaining valve R 2"
waste water collecting tankmade of polyethylene
ca. 1
360 70
Ø57-61
inletDN100
inletDN100
drain plug
flaps forbuoyancy control pneumatic control
free flow pumpgrain size 38 mm
as option:additionally inlet socket DN50
ventilation DN70
pitot tube
625
min
.250 max
.450
Ø50
5545
0 (Z
1)
Ø640
245
180
280
70
mini compressorfor air bubble injection
connectionpneumaticcontrol cable(4 m long)
switch box plug-in ready(250 x 195 x 100)
connectioncentralised fault signal(4m long)
motor cable(4m long)
electr. attachment for mini compressor
cable1.5 m long withCEKON-connector 16 A
ACO
617
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er f
ree
of
faec
es
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water free of faeces
Remark: Maximum temperature of wastewater is only allowed for a short time .
Infobox
Type Motor ra-ting
Current con-
sumpti-on
Voltage Revolu-tions
Grain size
Total volume
Useable volume Weight Article No.
P1 P2 Inlet height
Z1
Inlet from above
[kW] [kW] [A] [V] [U/min]
[mm] [l] [l] [l] [kg]
Muli-Mini V 75-duo – D 1,3 0,55 1,3 400 2900 35 150 75 90 88 0175.07.72
Muli-Mini V 150-duo – D 2,5 1,1 2,5 400 2900 38 150 75 90 88 0175.08.33
Muli-Mini V 75-duo – W 1,3 0,55 3,8 230 2900 35 150 75 90 88 0175.18.47
Muli-Mini V 150-duo – W 2,5 1,1 8,2 230 2900 38 150 75 90 88 0175.24.84
Performance parameters
MULI-MINI-V 75
Min
dest
förd
erst
rom
DN
65/
70
Min
dest
förd
erst
rom
DN
50
MULI-MINI-V 150
Toleranzen ISO 2548/C
n = 2900 U/min
1512963 36333027242118
4321 10987650
2
4
6
8
10
12
14
16
Ges
amtfö
rder
höhe
H
[m]
[m³/h]
[l/s]
Förderstrom Q
Type Delivery head
Delivery flow Q with total delivery head H Conveyance media temperature
2 m 4 m 6 m 8 m 10 m 12 m Normal Maxi-mum
[m] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]Muli-Mini V 75-duo – D 2 – 7 6,2 4,0 2,0 40 60
Muli-Mini V 150-duo – D 2 – 12 9,3 7,7 6,2 4,8 3,3 1,8 40 60
Muli-Mini V 75-duo – W 2 – 7 6,2 4,0 2,0 40 60
Muli-Mini V 150-duo – W 2 – 12 9,3 7,7 6,2 4,8 3,3 1,8 40 60
618
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er f
ree
of
faec
es
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water free of faeces
Accessories
Designation compatible with Description Article No.
Ø62
91
Ø50
70
Inlet valve DN 50 Eco-Mobil ■
Muli-Mini ■
PVC ■
DN 50 ■
With sealing ring in accordance ■
with DIN 19538
0175.18.33
Ø12
0Ø
110
15
Ø13
380
176
140
10 Inlet valve DN 100Waste water lifting plants ■
Polyethylene grease separator ■
Polyethylene starch separator ■
PVC ■
Construction length: 176 mm ■
Weight: 2 .75 kg ■
0175.13.84
Connection port Muli-Mini mono/duo ■
DN 50 ■
Bushing type A ■
40 x 50 x R 1¾“Minimum installation height: ■
250 mm
0175.09.27
Special mounting piece Muli-Mini ■
As additional components for ■
the pressure pipe DN 80 0175.07.79
619
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er f
ree
of
faec
es
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water free of faeces
Page
Waste water lifting plant for pre-wall installation
FäkablockFäkablock II 622
Accessories 625
Waste water lifting plant for free-standing installa-tion
Muli-Series
Muli-Star 626
Muli-PE duo 628
Muli-PE-S mono 630
Muli-PE-S duo 632
Muli Pro-PE K duo 634
Muli Pro-PE V duo 636
Muli Pro-PE K parallel 638
Muli Pro-PE V parallel 640
Muli Pro 1 .x VA duo 642
Muli Pro 2 .x VA duo 644
Accessories 646
Pumps Waste water lifting plants Waste water containing faeces
Hinweis: @@ Dies ist eine Infobox-VORLAGEZubehör AAAAA ➔ Seite xxx .Zubehör BBBBB ➔ Seite xxx .
Infobox
621621
Page
Waste water lifting plant for pre-wall installation
FäkablockFäkablock II 622
Accessories 625
Waste water lifting plant for free-standing installa-tion
Muli-Series
Muli-Star 626
Muli-PE duo 628
Muli-PE-S mono 630
Muli-PE-S duo 632
Muli Pro-PE K duo 634
Muli Pro-PE V duo 636
Muli Pro-PE K parallel 638
Muli Pro-PE V parallel 640
Muli Pro 1 .x VA duo 642
Muli Pro 2 .x VA duo 644
Accessories 646
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for waste water containing faeces
Pumps Waste water lifting plants Waste water containing faeces
Section contents
622
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for pre-wall installationFäkablock
Pumps Waste water lifting plants Waste water containing faeces
Fäkablock II
Product information
ACO product advantages
Easy maintenance due to easily acces- ■
sible function elementsConnection of up to 3 toilets ■
High-grade waste water lifting plants in ■
accordance with EN 12050-1
Areas of application ■
For the drainage of toilet facilities �
Wall mounted or pre-wall installation ■
Channel impeller centrifugal pump in ■
block assemblySteel panel collector tank ■
Interior corrosion protection �
Coated exterior �
Switchgear ■
Protection category IP 54, enclosed �
with insulating materialWith 1 strip terminal �
With 1 motor contactor �
With 1 motor overload switch �
Signal lamp „malfunction“ �
Pneumatic level switching �
Signal device, visual and acoustic �
Network dependent �
With dry contact for fault signal „level �
high“
WC wall connection ■
2 opposite facing push-fit sockets for �
WC connectors, diameter: 90 mmInlet height bottom edge of FÄKA- �
BLOCK II up to the middle of the WC drain: 340 mmAdditional WC connection on the �
container-side with inlet sockets DN 100 (accessories)
Shower connection ■
On the container side with eccen- �
tric inlet socket: DN 50, DN 70 or DN 100 (accessories)
Washbasin connection ■
Container side DN 50, DN 70 or �
DN 100 (accessories) or on the mo-tor compartment side DN 40 KA
Pressure pipe connection ■
Backflow valve with special mounting �
element for elastic connection of the pressure pipe: DN 100With drain spigot R � ½“ for emptying the pressure pipe
Connection ventilation line ■
Pipe sockets for connection with CV �
connecting collar: DN 70/SML or KA pipe
Aluminium screen for motor compart- ■
mentAnodized matt surface �
With aeration slots �
623
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for pre-wall installationFäkablock
Pumps Waste water lifting plants Waste water containing faeces
Ordering information
FFB
Ø50
800
580
10
904
Ø14022
012
013
088
7518
0
ca. 1004
263
ca. 964
20
OFF
ONWarn
pressure pipe DN 100 SMLor DN 80 on request
(optional)
switch boxincludinglevel switch
inletwashbasin
backflow valve DN 80with integrated special
fastening piece
ventilation DN 70 SML
inlet is blind locked !optional inlet connectionDN 50 / 70 / 100 SML- accessory-
mounting supports fortoilet with flushing valve
connection forwashbasinDN 40 / KA
The maintenance opening in the engine compartment can be mounted left and / or right to the container1x front cover made of aluminum with frame-like spacer(visible side) 2 x 390 x 6301x cover plate made of steel(hidden side) 3 x 365 x 605
emptying R 1/2
displayshows detail with cover plate made ofaluminium
plug-in sleeve DN 80 (Ø90)for toilet- double-sided-
630
x 39
0 x
2
605
x 36
5 x
3
DN
40/
KA
390
Ø75
ca. 1
210
120
flushing cistern for building inGEBERIT-KOMBIFIX – on site
double-sided possible
91
Type Motor rating Current con-
sumpti-on
Voltage Revolu-tions
Grain size
Total volume
Useable volume
Weight Article No.
P1 P2 Inlet height
Z1[kW] [kW] [A] [V] [U/min] [mm] [l] [l] [kg]
Fäkablock-II 1 0,75 2,15 400 1450 55 40 22 132 0175.00.90
624
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for pre-wall installationFäkablock
Pumps Waste water lifting plants Waste water containing faeces
Performance parameters
1
2
3
4
5
6Toleranzen ISO 2548/C
n = 1450 U/min
Min
dest
förd
erst
rom
DN
80
Min
dest
förd
erst
rom
DN
100
36302418126
10987654321
0
0
0
[m]
Förderstrom Q
Ges
amtfö
rder
höhe
H
[l/s][m³/h]
Type Delivery head Delivery flow Q with total delivery head H
Conveyance media temperature
1 m Normal Maximum[m] [l/s] [°C] [°C]
Fäkablock-II 1 – 3,5 9,2 45 80
625
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for pre-wall installationFäkablock
Pumps Waste water lifting plants Waste water containing faeces
Accessories
Designation compatible with Description Article No.
Hand switch Fäkablock II ■3 pole ■
With padlock stop ■0159.12.37
135 60
Ø60
175
25
Inlet socket Fäkablock II ■
DN 50/SML ■
Eccentric ■
In accordance with DIN 19522 ■
0159.04.33
60
Ø80
15
Inlet socket Fäkablock II ■
DN 70/SML ■
Eccentric ■
In accordance with DIN 19522 ■
0159.04.34
60
Ø11
0
Inlet socket Fäkablock II ■
DN 100/SML ■
Eccentric ■
In accordance with DIN 19522 ■
0159.30.05
O-ring Fäkablock II ■
Muli series ■
As additional components for ■
the pressure pipe DN 80 0159.37.97
626
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water containing faeces
Muli-Star
Product information
ACO product advantages
Marginal weight 31 kg ■
Smoothness via low revolutions ■
Free passage: 57 mm ■
Quick fitting ■
Ready for connection ■
Installation via manhole cover KM 600 ■
possibleBlockage-free free flow impeller ■
Area of application ■
Detached houses �
Basement flats �
Polyethylene collector tank ■
With scour plug ■
With revision opening for easy mainte- ■
nance, diameter: 133 mmWith mounting set for buoyancy safety ■
anchoringConnection for the manual membrane ■
pump R 1½“With 3 horizontal inlet sockets DN 100 ■
With 1 vertical inlet socket DN 50/ ■
DN 100With ventilation connection DN 50 for ■
connection to the plastic pipe
Pressure pipe connection ■
Special backflow valve with integra- �
ted ball in cabinet and with emptying screwWith integrated special mounting ele- �
ment DN 100 for elastic connection of the pressure pipe with an outside diameter of 108 – 114 .3 mmWith connecting flange for stop valve �
DN 80 PN 10Pump unit ■
3-phase motor (MDS1): 400 V, 50 Hz �
AC motor (MWS1): 230 V, 50 Hz �
Protection category IP 68 �
With blockage-free free flow impeller �
With float switch, settable to inlet height ■
Switching and warning device ■
Protection category IP 54 �
With 1 .5 m cable and CEE plug (with �
MDS1) or with safety plug (MWS1)With dry contact centralised fault �
signal and operating signalInc . 5 m pneumatic control line bet- �
ween the lifting plant and control boxLGA test certificate: No . 7391278-01 ■
Ordering information
inlet DN 100
250
180
Ø52
Ø110
40
45
575
520
135
510
127
500
Ø52
40047
0
700
Ø108 - 114,3
100
175
inlet DN 50
integrated specialbackflow valvewith lifting device
outlet R 1
special fixing partfor elastic connection to the pressure pipeline DN 80/100(option: seal ring DN 80)
attachment for buoyancy safeguard
access screwcap DN 125
cap / passage float switch
free flow centrifugal pump
Ø11
0
Ø11
0
ventilation DN 50
collecting tank
switch box(plug in)
230
250 (T100) cable (1.5 m long)with CEE-connector (MDS) orisolated ground connector (MWS)
connection Ø 48 for membrane pump
627
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water containing faeces
Remark: Maximum temperature of wastewater is only allowed for a short time .
Infobox
Type Motor ra-ting
Characteristics Grain size
Total volu-me
Useable volume Weight Article No.
P1 P2 Cur-rent con-
sump-tion
Vol-tage
Fre-quen-
cy
Re-volu-tions
Inlet height
Z1
Inlet height
Z2
Inlet from abo-ve
[kW] [kW] [A] [V] [Hz] [U/min]
[mm] [l] [l] [l] [l] [kg]
Muli-Star MDS1 1 0,75 1,93 400 50 1380 55 60 20 25 30 31 1200.00.00
Muli-Star MWS1 1,1 0,75 5,05 230 50 1410 55 60 20 25 30 31 1200.00.01
Performance parameters
0
1
2
3
4
5
6
7
8
0 1 2 3 4 5 6 7 8 9 10 11 12
0 5 10 15 20 25 30 35 40 45
Min
dest
förd
erst
rom
DN
80
Min
dest
förd
erst
rom
DN
100
n = 1400 U/min
Leistungsdiagramm Toleranzen ISO 2548/C
[m³/h]
[l/s]
Ges
amtfö
rder
höhe
H
Förderstrom Q
[m]
MWS (W
echselstrom)
MDS (Drehstrom)
Type Delive-ry head
Delivery flow Q with total delivery head H Conveyance media temperature
2 m 4 m 6 m Normal Maximum[m] [l/s] [l/s] [l/s] [°C] [°C]
Muli-Star MDS1 2 – 6,4 10,9 8,6 4,5 40 60
Muli-Star MWS1 2 – 6,4 9,7 4,4 40 60
628
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water containing faeces
Muli-PE duo
Product information
ACO product advantages
Quick fitting ■
Ready for connection ■
High useable volume - up to 100 l ■
Areas of application ■
Behind grease separator up to NS 7 - �
in conjunction with air bubble injectionApartment housing �
Office buildings �
Polyethylene collector tank ■
With drain plug ■
With connection for the manual membra- ■
ne pump R 1½“With mounting set for buoyancy safety ■
anchoringWith 2 horizontal inlet sockets DN 100/ ■
DN 150With 1 horizontal inlet socket with ■
gradation DN 100/DN 150With ventilation socket DN 100 for ■
connection to the plastic pipe
Pressure pipe connection ■
With 2 special backflow valves DN 80 �
With drain spigot R � ½“Inc . Y-branch pipe with cleaning ope- �
ning and special mounting element DN 80/DN 100 for elastic connection of the pressure pipe with an outside diameter of: 108 – 114 .3 mm
2 pump units ■
Motor 400 V, 50 Hz �
Protection category IP 68 �
With channel impeller �
Pneumatic level switching with pilot tube ■
and pneumatic control lineSwitching and warning device ■
Protection category IP 54 �
With 1 .5 m cable and CEE plug �
With dry contact centralised fault �
signal and operating signalInc . 4 m pneumatic control line bet- �
ween the lifting plant and control box
Ordering information
355
200
260ca
. 950
270
3 160
165
70 110160
70165
650
485
750
105210
810890
975
100
124
70 70
124
55
5825
0 (Z
1)40
0 (Z
2)
Ø108-114
ventilation DN100
tube sockets Ø48 mm for connection to manual membrane pump R 1 ½“
pneumatic control
waste water collecting tank made of polyethylenedrain plug
single chanel impeller centrifugal pump
flaps for buoyancy control
upper inlet socket with selectable nominal diameterDN 100/150
lateral inlet socket with selectable nominal diameterDN100/150
pitot tube
pressure pipe
special fastening pieceDN 80/100
Y-branch pipe DN 80
backflow valve DN 80
connection pneumatic controlcable (4m long)
switch box plug-in ready(250 x 195 x 100)
connectioncentralised fault signal
motor cable(4m long )
connectionmini compressor
cable 1.5 m long with CEKON-plug 16 A
DN100
629
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water containing faeces
Remark: Maximum temperature of wastewater is only allowed for a short time .
Infobox
Type Motor ra-ting
Characteristics Grain size
Total volu-me
Useable volume Weight Article No.
P1 P2 Cur-rent con-
sump-tion
Vol-tage
Fre-quen-
cy
Re-volu-tions
Inlet height
Z1
Inlet height
Z2
Inlet from abo-ve
[kW] [kW] [A] [V] [Hz] [U/min]
[mm] [l] [l] [l] [l] [kg]
Muli-PE duo 1 0,75 2,15 400 50 1500 55 145 80 100 100 180 0159.04.17Muli-PE/1
duo 2,01 1,5 3,6 400 50 3000 55 145 80 100 100 180 0159.04.19
Muli-PE/2 duo 2,94 2,2 5,2 400 50 3000 55 145 80 100 100 185 0159.04.21
Muli-PE/3 duo 3,87 3 7,1 400 50 3000 55 145 80 100 100 190 0159.04.23
Performance parameters
20
18
16
14
12
10
8
6
4
2
0
24
22
107,552,5 2017,51512,50
MULI-PE / 1
MULI-PE / 2
MULI-PE / 3
6 3630241812 787266605448420
Toleranzen ISO 2548/C
Min
dest
förd
erst
rom
DN
100
Min
dest
förd
erst
rom
DN
80
MULI-PE
Förderstrom Q
Leistungsdiagramm[m]
Ges
amtfö
rder
höhe
H
[l/s]
[m³/h]
Type Delive-ry head
Delivery flow Q with total delivery head H Conveyance media tempe-
rature2 m 4 m 6 m 8 m 10 m 12 m 14 m 16 m 18 m Nor-
malMaxi-mum
[m] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]Muli-PE duo 2 – 6 12,7 10,0 5,8 40 60Muli-PE/1
duo 8 – 12 11,5 8,66 5,67 40 60
Muli-PE/2 duo 8 – 16 15,6 12,7 9,97 7,08 4,25 40 60
Muli-PE/3 duo 8 – 18 19,1 16,4 13,6 10,6 7,58 4,66 40 60
630
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water containing faeces
Muli-PE-S mono
Product information
ACO product advantages
High-grade waste water lifting plant ■
with submerged motor pump and cutting mechanismVarious inlet heights ■
Low costs via small pressure pipe ■
profile
Areas of application ■
Renovation of an old building �
With longer pressure pipe to channel �
Polyethylene collector tank ■
With drain plug ■
With connection for the manual membra- ■
ne pump R 1½“With mounting set for buoyancy safety ■
anchoringWith 3 horizontal inlet sockets DN 100 ■
With 1 horizontal inlet socket with ■
gradation DN 100/DN 150With ventilation socket DN 100 for ■
connection to the plastic pipePressure pipe connection ■
With 1 ball backflow stop R 2“ �
With stop valve R 2“ �
Pump unit ■
Motor 400 V, 50 Hz �
Protection category IP 68 �
With outside cutting mechanism �
Pneumatic level switching with pilot tube ■
and pneumatic control lineSwitching and warning device ■
Protection category IP 54 �
With 1 .5 m cable and CEE plug �
With dry contact centralised fault �
signal and operating signalInc . 4 m pneumatic control line bet- �
ween the lifting plant and control box
Ordering information
ventilationDN 100
flaps for buoyancy control
waste water collecting tankmade of polyethylene
upper inlet socket withselectable nominal diameter DN 100/DN150cut off at indents as requiredpneumatic control
lateral inlet socket DN 100
pitot tube
pump with cutting mechanism
stop valve R 2
tube sockets Ø48 mmfor connection tomanual-diaphragm pump R 1 ½“
drain plug
400
(Z3)
165
210105
660765
100
120
600
250
(Z2)
180
(Z1)
300
80
110 55
í160
48565
0 5
8 7
0
70
200 55
ca. 7
60
R 2
mounting bracketsfor mini compressor
mini compressor
connection pneumatic control cable (4 m long)
cable 1.5 m long with CEKON-plug 16 A
electr. connection for mini compressor
connectionrcentralised fault signal
motor cable(4m long)
switch box plug-in ready(250x195x100)
í110
í110
100
tube sockets Ø48 mmfor connection tomanual-diaphragm pump R 1 ½“
631
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water containing faeces
Remark: Maximum temperature of wastewater is only allowed for a short time .
Infobox
Type Motor ra-ting
Characteristics Total volu-me
Useable volume Weight Article No.
P1 P2 Cur-rent con-
sump-tion
Vol-tage
Fre-quen-
cy
Re-volu-tions
Inlet height
Z1
Inlet height
Z2
Inlet height
Z3
Inlet from abo-ve
[kW] [kW] [A] [V] [Hz] [U/min]
[l] [l] [l] [l] [l] [kg]
Muli-PE-S-100 mono
1,2 0,9 2,3 400 50 2900 80 10 35 50 50 80 0159.03.91
Muli-PE-S-200 mono
2,5 1,7 4,1 400 50 2900 80 10 35 50 50 85 0175.19.00
Performance parameters
Min
dest
förd
erst
rom
DN
50
1814,4 21,619,816,2
3,5 5,54,54 65[l/s]
[m³/h]0
8
6
4
2
0
0
22
20
18
16
14
12
10
0,5 1 1,5 2,52 3
1,8 3,6 5,4 7,2 9 10,8 12,6
Leistungsdiagramm Toleranzen ISO 2548/C
26
24
28[m]
MULI - PE - S 100
MULI - PE - S 200
Förderstrom Q
Ges
amtfö
rder
höhe
H
Type Delive-ry head
Delivery flow Q with total delivery head H Conveyance media tem-
perature2 m 4 m 6 m 8 m 10 m 12 m 14 m 16 m 18 m 20 m 22 m 24 m Nor-
malMa-xi-
mum[m] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]
Muli-PE-S-100 mono 2 – 18 3,57 3,4 3,2 3,0 2,75 2,43 2,1 1,75 1,3 40 60
Muli-PE-S-200 mono 2 – 24 5,93 5,65 5,36 5,05 4,72 4,34 3,94 3,47 2,96 2,38 1,73 1,2 40 60
632
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water containing faeces
Muli-PE-S duo
Product information
ACO product advantages
High-grade waste water lifting plant ■
with submerged motor pump and cutting mechanismVarious inlet heights ■
Low costs via small pressure pipe ■
profile
Areas of application ■
Renovation of an old building �
With longer pressure pipe to channel �
Objects containing fluids with solid �
or fibrous contents e .g . laundries, abattoirs
Polyethylene collector tank ■
With drain plug ■
With connection for the manual membra- ■
ne pump R 1½“With mounting set for buoyancy safety ■
anchoring
With 2 horizontal inlet sockets DN 100/ ■
DN 150With 1 horizontal inlet socket with ■
gradation DN 100/DN 150With ventilation socket DN 100 for ■
connection to the plastic pipePressure pipe connection ■
With 2 ball backflow stops R 2“ �
With 2 stop valves R 2“ �
2 pump units ■
Motor 400 V, 50 Hz �
Protection category IP 68 �
With outside cutting mechanism �
Pneumatic level switching with pilot tube ■
and pneumatic control lineSwitching and warning device ■
Protection category IP 54 �
With 1 .5 m cable and CEE plug �
With dry contact centralised fault �
signal and operating signalInc . 4 m pneumatic control line bet- �
ween the lifting plant and control box
Ordering information
upper inlet socket with selectable nominal diameterDN 100/150
connection pneumaticcontrol cable (4m long)
switch box plug-in ready(250 x 195 x 100)
connectioncentralised fault signal
motor cable(4m long)
connectionmini compressor
cable 1.5 m long withCEKON-plug 16 A
ventilation DN100
lateral inlet socket with selectable nominal diameter DN100/150
pitot tube
tube socket Ø48 mmfor connecting tomanual membrane pump R 1 ½“
pneumatic control
waste water collecting tank made of polyethylene
5520
0ca
. 910
105210
1005
flaps forbuoyancy control
810
100
124
300
750
250
(Z1)
400
(Z2)
5848
5
55
7070 124
R2
drain plug
pump with cutting mechanism
pressure pipe
Ø110Ø160
7016
5
70165
650
ball retaining valve R 2"
633
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water containing faeces
Remark: Maximum temperature of wastewater is only allowed for a short time .
Infobox
Type Motor ra-ting
Characteristics Total volu-me
Useable volume Weight Article No.
P1 P2 Cur-rent con-
sump-tion
Vol-tage
Fre-quen-
cy
Re-volu-tions
Inlet height
Z1
Inlet height
Z2
Inlet from above
[kW] [kW] [A] [V] [Hz] [U/min]
[l] [l] [l] [l] [kg]
Muli-PE-S-100 duo 1,2 0,9 2,3 400 50 2900 105 40 60 60 180 0159.04.24
Muli-PE-S-200 duo 2,5 1,7 4,1 400 50 2900 105 40 60 60 185 0175.02.67
Performance parametersM
inde
stfö
rder
stro
m D
N 5
0
1814,4 21,619,816,2
3,5 5,54,54 65[l/s]
[m³/h]0
8
6
4
2
0
0
22
20
18
16
14
12
10
0,5 1 1,5 2,52 3
1,8 3,6 5,4 7,2 9 10,8 12,6
Leistungsdiagramm Toleranzen ISO 2548/C
26
24
28[m]
MULI - PE - S 100
MULI - PE - S 200
Förderstrom Q
Ges
amtfö
rder
höhe
H
Type Delive-ry head
Delivery flow Q with total delivery head H Conveyance media tem-
perature2 m 4 m 6 m 8 m 10 m 12 m 14 m 16 m 18 m 20 m 22 m 24 m Nor-
malMa-xi-
mum[m] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]
Muli-PE-S-100 duo 2 – 18 3,57 3,4 3,2 3,0 2,75 2,43 2,1 1,75 1,3 40 60
Muli-PE-S-200 duo 2 – 24 5,93 5,65 5,36 5,05 4,72 4,34 3,94 3,47 2,96 2,38 1,73 1,2 40 60
634
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water containing faeces
Muli Pro-PE K duo
Product information
ACO product advantages
Large container useable volume ■
Various inlet heights ■
Pilot tube and air bubble injection ■
ensure high operating safetySuitable for fatty waste water ■
Can be extended to a parallel plant ■
Energy-saving channel impeller pump ■
Adapted to door dimensions: 780 mm ■
Areas of application ■
Apartment housing �
Smaller commercial objects with a �
large waste water volumeBehind the grease separator up to �
NS 20For long pressure pipes with large �
height differencesPolyethylene collector tank ■
With drain plug ■
With connection for the manual membra- ■
ne pump R 1½“With mounting set for buoyancy safety ■
anchoringWith 4 horizontal inlet sockets DN 150 ■
With 1 vertical inlet sockets DN 150 ■
With 1 revision opening, clear diameter: ■
320 mm
With ventilation socket DN 100 for ■
connection to the plastic pipePressure pipe connection ■
With 2 special backflow valves DN 80 �
(DN 100 for MULI Pro-PE K-75 duo) with short-spell ventilationWith Y-branch pipe �
With special mounting piece DN 100 �
for connection of the pressure pipe with an external diameter of 108 – 114 .3 mm
2 pump units ■
Motor 400 V, 50 Hz �
Protection category IP 68 �
With shaft and mechanical seal �
With channel impeller �
Pneumatic level switching with pilot tube ■
and pneumatic control lineSeparate pilot tube for high alarm ■
Mini compressor for air bubble injection ■
Switching and warning device ■
Protection category IP 54 �
With 1 .5 m cable and CEE plug �
With dry contact centralised fault �
signal and operating signalInc . 7 m cabling between the lifting �
plant and control box
Ordering information
*ca.
153
0
switch box plug-in ready( 250 x 195 x 100 )
cable 1.5 m long withCEKON-plug 16 A
connection pneumatic control cable
motor cable(4m long)
connectionmini compressor
connection forpotential-freecentralised alarm signalsand operation signals
connection for emergency powersupplies
mini compressor for air bubble injection
65258
ca. 1
410
*300260
180
*190
285
130
Ø108 bis 114,3
95100
120
600 80
0 940
95
1300
750
430
ca. 1500
100
215
780
250
special backflow valveDN80 (x DN 100)with draining screw
ventilationDN100
drain plug
Flaps for buoyancy control
pneumatic control
special fastening piece DN 100
Stop valveDN 80 (x DN 100)-accessories-
channel impeller centrifugal pumpgrain size 70-90 mm
connection R 1 ½for manual membranepump
maintenance openingLW 320
pressure pipe DN 100
Y-branch pipe DN 80/80/100(x DN 100/100/100)
inlet socketDN 150
connection pneumatic control cable"ALARM 1"
635
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water containing faeces
Remark: Maximum temperature of wastewater is only allowed for a short time .
Infobox
Type Motor rating
Characteristics Grain size
Total volu-me
Useable volume Weight Article No.
P1 P2 Cur-rent con-
sump-tion
Vol-tage
Fre-quen-
cy
Re-volu-tions
Inlet hei-ght Z1
Inlet hei-ght Z2
Inlet hei-ght Z3
Inlet from abo-ve
[kW] [kW] [A] [V] [Hz] [U/min]
[mm] [l] [l] [l] [l] [l] [kg]
Muli Pro-PE K-15 duo 2,01 1,5 3,6 400 50 1450 70 520 240 305 330 330 275 0175.13.17
Muli Pro-PE K-22 duo 2,94 2,2 5,2 400 50 1450 70 520 240 305 330 330 285 0175.13.18
Muli Pro-PE K-30 duo 3,87 3 6,6 400 50 1450 70 520 240 305 330 330 380 0175.13.19
Muli Pro-PE K-55 duo 6,71 5,5 11,6 400 50 1450 70 520 240 305 330 330 425 0175.13.20
Muli Pro-PE K-75 duo 8,97 7,5 15,5 400 50 1450 100 520 240 305 330 330 470 0175.13.21
Performance parameters
Min
dest
förd
erst
rom
DN
80
Leistungsdiagramm Toleranzen ISO 2548/C
n=1450 U/min
Min
dest
förd
erst
rom
DN
100
20
18
16
14
12
10
8
6
4
2
00
0 5 10 15 20 25 30 35 40 45 50
12 24 36 48 60 72 84 96 108 120 132 144 156 168 180 192
K-75
K-55K-30K-22K-15
Ges
amtfö
rder
höhe
H
[m]
[m³/h]
[l/s]
Förderstrom Q
Type Delive-ry head
Delivery flow Q with total delivery head H Conveyance me-dia temperature
4 m 6 m 8 m 10 m 12 m 14 m 16 m 18 m Normal Maxi-mum
[m] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]Muli Pro-PE K-15 duo 3 – 8 18,3 11,7 5,8 40 60
Muli Pro-PE K-22 duo 3 – 10 24,2 18,5 12,5 5,3 40 60
Muli Pro-PE K-30 duo 4 – 14 33,5 28,4 23,1 16,8 10,3 4,2 40 60
Muli Pro-PE K-55 duo 4 – 17 37,3 32,7 28,1 23,1 18,8 14,1 9,4 40 60
Muli Pro-PE K-75 duo 6 – 18 51,8 46,2 39,2 31,7 23,2 14,2 6,8 40 60
636
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water containing faeces
Muli Pro-PE V duo
Product information
ACO product advantages
Large container useable volume ■
Various inlet heights ■
Pilot tube and air bubble injection ■
ensure high operating safetySuitable for fatty waste water ■
Can be extended to a parallel plant ■
Blockage-free free flow impeller ■
Adapted to door dimensions: 780 mm ■
Areas of application ■
Apartment housing �
Smaller commercial objects with a �
large waste water volumeFor waste water with long-fibre �
contentsBehind the grease separator up to �
NS 15Polyethylene collector tank ■
With drain plug ■
With connection for the manual membra- ■
ne pump R 1½“With mounting set for buoyancy safety ■
anchoringWith 4 horizontal inlet sockets DN 150 ■
With 1 vertical inlet sockets DN 150 ■
With 1 revision opening, clear diameter: ■
320 mmWith ventilation socket DN 100 for ■
connection to the plastic pipePressure pipe connection ■
With 2 special backflow valves DN 80 �
with short-spell ventilationWith Y-branch pipe �
With special mounting piece DN 100 �
for connection of the pressure pipe with an external diameter of 108 – 114 .3 mm
2 pump units ■
Motor 400 V, 50 Hz �
Protection category IP 68 �
With shaft and mechanical seal �
With free flow impeller �
Pneumatic level switching with pilot tube ■
and pneumatic control lineSeparate pilot tube for high alarm ■
Mini compressor for air bubble injection ■
Switching and warning device ■
Protection category IP 54 �
With 1 .5 m cable and CEE plug �
With dry contact centralised fault �
signal and operating signalInc . 4 m cabling between the lifting �
plant and control box
Ordering information
switch box plug-in ready(250 x 195 x 100)
cable 1.5 m long with CEKON-plug 16 A
connection pneumatic control cable
motor cable(4m long)
connectionmini compressor
connection pneumatic control cable"ALARM 1"
connection forpotential-freecentralised alarm signalsand operation signalsl
connection for emergency power supplies
mini compressor for air bubble injection
pressure pipe DN 100
special fastening piece DN 80/100
Stop valve DN 80 -accessories-
Ø108 bis 114,3
260
Y-branch pipe DN 80/80/100
180
270
160
free flow pump grain size 80 mm
65258
ca. 1
480
120
600
(Z1)
800
(Z3) 940
95
95
100
Inlet socketDN 150
special backflow valve DN 80 with draining screw
1300
750
(Z2)
inlet socketDN 150
pneumatic control
ventilationDN100
flaps forbuoyancy control
maintenance opening LW 320
ca. 1440
215250
780
325
connection R 1 ½for manual membrane pump
637
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water containing faeces
Remark: Maximum temperature of wastewater is only allowed for a short time .
Infobox
Type Motor ra-ting
Characteristics Grain size
Total volu-me
Useable volume Weight Article No.
P1 P2 Cur-rent con-
sump-tion
Vol-tage
Fre-quen-
cy
Re-volu-tions
Inlet hei-ght Z1
Inlet hei-ght Z2
Inlet hei-ght Z3
Inlet from abo-ve
[kW] [kW] [A] [V] [Hz] [U/min]
[mm] [l] [l] [l] [l] [l] [kg]
Muli Pro-PE V-15
duo2,01 1,5 4,1 400 50 1450 80 520 240 305 330 330 210 0175.12.89
Muli Pro-PE V-22
duo2,94 2,2 5,2 400 50 3000 80 520 240 305 330 330 215 0175.12.90
Muli Pro-PE V-30
duo3,87 3 7,2 400 50 3000 80 520 240 305 330 330 225 0175.12.91
Muli Pro-PE V-40
duo5,1 4 10,3 400 50 3000 80 520 240 305 330 330 230 0175.12.92
Performance parameters
Leistungsdiagramm Toleranzen ISO 2548/C15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
0 5 10 15 20 25 30 35 40 45 50 55 60 65
Min
dest
förd
erst
rom
DN
80
Min
dest
förd
erst
rom
DN
100
V-40
V-30V-22
V-15
Ges
amtfö
rder
höhe
H
[m]
[m³/h][l/s]
Förderstrom Q
Type Delive-ry head
Delivery flow Q with total delivery head H Conveyance media tem-perature
4 m 6 m 8 m 10 m 12 m Normal Maximum[m] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]
Muli Pro-PE V-15 duo 3 – 6 11,0 3,1 40 60
Muli Pro-PE V-22 duo 5 – 7 7,8 40 60
Muli Pro-PE V-30 duo 6 – 10 13,15 9,4 4,35 40 60
Muli Pro-PE V-40 duo 8 – 12 13,1 9,6 4,7 40 60
638
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water containing faeces
Muli Pro-PE K parallel
Product information
ACO product advantages
Large container useable volume ■
8 inlets, 4 inlet heights ■
Pilot tube and air bubble injection ■
ensure high operating safetyEnergy-saving channel impeller pump ■
Adapted to door dimensions: 780 mm ■
Areas of application ■
Commercial or industrial objects with �
a large waste water volumeFor long pressure pipes with large �
height differencesPolyethylene collector tank ■
With drain plug ■
With connection for the manual membra- ■
ne pump R 1½“With mounting set for buoyancy safety ■
anchoringWith 6 horizontal inlet sockets DN 150 ■
With 2 vertical inlet sockets DN 150 ■
With 2 revision openings, clear diame- ■
ter: 320 mmWith ventilation socket DN 100 for ■
connection to the plastic pipe
Pressure pipe connection ■
With 2 special backflow valves DN 80 �
(DN 100 for MULI Pro-PE K-75 Paral-lel) with short-spell ventilationWith Y-branch pipe �
With special mounting piece DN 100 �
for connection of the pressure pipe with an external diameter of 108 – 114 .3 mm
2 pump units ■
Motor 400 V, 50 Hz �
Protection category IP 68 �
With shaft and mechanical seal �
With channel impeller �
Pneumatic level switching with pilot tube ■
and pneumatic control lineSeparate pilot tube for high alarm ■
Mini compressor for air bubble injection ■
Switching and warning device ■
Protection category IP 54 �
With 1 .5 m cable and CEE plug �
With dry contact centralised fault �
signal and operating signalInc . 7 m cabling between the lifting �
plant and control box
Ordering information
*ca.
153
0
switch box plug-in ready(250 x 195 x 100) cable 1.5 m long with
CEKON-connector 16 A
connection pneumatic control cable
motor cable(4m long ) connection
mini compressor
connection pneumatic control cable"ALARM 1"
connection forpotential-freecentralised alarm signalsand operation signals
connection for emergency power supplies
mini compressor for air bubble injection
special backflow valve DN80 (x DN 100) with draining screw
channel impeller centrifugal pump grain size 70-90 mmventilation DN100
drain plug
Flaps for buoyancy control
pneumatic control
special fastening piece DN 100
stop valveDN 80 (x DN 100)-accessories-
connection R 1 ½for manual membrane pump
maintenance openingLW 320
pressure pipe DN 100
Y-branch pipe DN 80/80/100(x DN 100/100/100)
inlet socketDN 150
overflowDN 150
*300
*190
Ø108 bis 114,3
6525
8
ca. 1
410
1300
430
100
1500
860
1640
215
95100
9512
060
0 (Z
1) 800
(Z3)
940
780 780
750
(Z2)
inlet socketDN 150
260
180
285
130
250
639
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water containing faeces
Remark: Maximum temperature of wastewater is only allowed for a short time .
Infobox
Type Motor rating
Characteristics Grain size
Total volu-me
Useable volume Weight Article No.
P1 P2 Cur-rent con-
sump-tion
Vol-tage
Fre-quen-
cy
Re-volu-tions
Inlet hei-ght Z1
Inlet hei-ght Z2
Inlet hei-ght Z3
Inlet from abo-ve
[kW] [kW] [A] [V] [Hz] [U/min]
[mm] [l] [l] [l] [l] [l] [kg]
Muli Pro-PE K-15 parallel
2,01 1,5 3,6 400 50 1450 70 1040 480 610 660 660 315 0175.13.23
Muli Pro-PE K-22 parallel
2,94 2,2 5,2 400 50 1450 70 1040 480 610 660 660 325 0175.13.24
Muli Pro-PE K-30 parallel
3,87 3 6,6 400 50 1450 70 1040 480 610 660 660 420 0175.13.25
Muli Pro-PE K-55 parallel
6,71 5,5 11,6 400 50 1450 70 1040 480 610 660 660 465 0175.13.26
Muli Pro-PE K-75 parallel
8,97 7,5 15,5 400 50 1450 100 1040 480 610 660 660 510 0175.13.27
Performance parameters
Min
dest
förd
erst
rom
DN
80
Leistungsdiagramm Toleranzen ISO 2548/C
n=1450 U/min
Min
dest
förd
erst
rom
DN
100
20
18
16
14
12
10
8
6
4
2
00
0 5 10 15 20 25 30 35 40 45 50
12 24 36 48 60 72 84 96 108 120 132 144 156 168 180 192
K-75
K-55K-30K-22K-15
Ges
amtfö
rder
höhe
H
[m]
[m³/h]
[l/s]
Förderstrom Q
Type Delive-ry head
Delivery flow Q with total delivery head H Conveyance me-dia temperature
4 m 6 m 8 m 10 m 12 m 14 m 16 m 18 m Normal Maxi-mum
[m] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]Muli Pro-PE
K-15 parallel 3 – 8 18,3 11,7 5,8 40 60
Muli Pro-PE K-22 parallel 3 – 10 24,2 18,5 12,5 5,3 40 60
Muli Pro-PE K-30 parallel 4 – 14 33,5 28,4 23,1 16,8 10,3 4,2 40 60
Muli Pro-PE K-55 parallel 4 – 17 37,3 32,7 28,1 23,1 18,8 14,1 9,4 40 60
Muli Pro-PE K-75 parallel 6 – 18 51,8 46,2 39,2 31,7 23,2 14,2 6,8 40 60
640
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water containing faeces
Muli Pro-PE V parallel
Product information
ACO product advantages
Large container useable volume ■
8 inlets, 4 inlet heights ■
Pilot tube and air bubble injection ■
ensure high operating safetyBlockage-free free flow impeller ■
Adapted to door dimensions: 780 mm ■
Areas of application ■
Commercial or industrial objects with �
a large waste water volumeApartment housing �
Behind the grease separator up to �
NS 20For waste water with long-fibre �
contentsPolyethylene collector tank ■
With drain plug ■
With connection for the manual membra- ■
ne pump R 1½“With mounting set for buoyancy safety ■
anchoringWith 6 horizontal inlet sockets DN 150 ■
With 2 vertical inlet sockets DN 150 ■
With 2 revision openings, clear diame- ■
ter: 320 mm
With ventilation socket DN 100 for ■
connection to the plastic pipePressure pipe connection ■
With 2 special backflow valves DN 80 �
with short-spell ventilationWith Y-branch pipe �
With special mounting piece DN 100 �
for connection of the pressure pipe with an external diameter of 108 – 114 .3 mm
2 pump units ■
Motor 400 V, 50 Hz �
Protection category IP 68 �
With shaft and mechanical seal �
With blockage-free free flow impeller �
Pneumatic level switching with pilot tube ■
and pneumatic control lineSeparate pilot tube for high alarm ■
Mini compressor for air bubble injection ■
Switching and warning device ■
Protection category IP 54 �
With 1 .5 m cable and CEE plug �
With dry contact centralised fault �
signal and operating signalInc . 4 m cabling between the lifting �
plant and control box
Ordering information
switch box plug-in ready(250 x 195 x 100)
cable 1.5 m long with CEKON-plug 16 A
connection pneumatic control cable
motor cable(4m long)
connectionmini compressor
connection pneumatic control cable"ALARM 1"
connection forpotential-freecentralised alarm signalsand operation signals
connection for emergency power supplies
mini compressor for air bubble injection
6525
8ca
. 147
0
260
180
285
130
1300drain plug
free flow pump grain size 80 mm
780 780
special fastening pieceDN 100
stop valve DN 80-accessories-
Y-branch pipe DN 80/80/100 special backflow valveDN 80 (x DN 100)with draining screw
750
(Z2)
120
600
(Z1) 80
0 (Z
3)94
0
95100
95 Inlet socketDN 150
pressure pipe DN 100
Ø108 bis 114,3
pneumatic control ventilation DN100
overflowDN 150
inlet socketDN 150Flaps for
buoyancy control
connection R 1 ½for manual membrane pump
maintenance openingLW 320
430
860
1640
250
215
325
641
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water containing faeces
Remark: Maximum temperature of wastewater is only allowed for a short time .
Infobox
Type Motor rating
Characteristics Grain size
Total volu-me
Useable volume Weight Article No.
P1 P2 Cur-rent con-
sump-tion
Vol-tage
Fre-quen-
cy
Re-volu-tions
Inlet hei-ght Z1
Inlet hei-ght Z2
Inlet hei-ght Z3
Inlet from abo-ve
[kW] [kW] [A] [V] [Hz] [U/min]
[mm] [l] [l] [l] [l] [l] [kg]
Muli Pro-PE V-15 parallel
2,01 1,5 4,1 400 50 1450 80 1040 480 610 660 660 210 0175.12.94
Muli Pro-PE V-22 parallel
2,94 2,2 5,2 400 50 3000 80 1040 480 610 660 660 215 0175.12.95
Muli Pro-PE V-30 parallel
3,87 3 7,2 400 50 3000 80 1040 480 610 660 660 225 0175.12.96
Muli Pro-PE V-40 parallel
5,1 4 10,3 400 50 3000 80 1040 480 610 660 660 230 0175.12.97
Performance parameters
Min
dest
förd
erst
rom
DN
80
Leistungsdiagramm Toleranzen ISO 2548/C
n=1450 U/min
Min
dest
förd
erst
rom
DN
100
20
18
16
14
12
10
8
6
4
2
00
0 5 10 15 20 25 30 35 40 45 50
12 24 36 48 60 72 84 96 108 120 132 144 156 168 180 192
K-75
K-55K-30K-22K-15
Ges
amtfö
rder
höhe
H
[m]
[m³/h]
[l/s]
Förderstrom Q
Type Delive-ry head
Delivery flow Q with total delivery head H Conveyance media tem-perature
4 m 6 m 8 m 10 m 12 m Normal Maximum[m] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]
Muli Pro-PE V-15 parallel 3 – 6 11,0 3,1 40 60
Muli Pro-PE V-22 parallel 5 – 7 7,8 40 60
Muli Pro-PE V-30 parallel 6 – 10 13,15 9,4 4,35 40 60
Muli Pro-PE V-40 parallel 8 – 12 13,1 9,6 4,7 40 60
642
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water containing faeces
Muli Pro 1.x VA duo
Product information
ACO product advantages
Forced activation upon „level high“ ■
ensures high operating securitySuitable for fatty waste water ■
Pilot tube and air bubble injection ■
ensure high operating safetyBlockage-free free flow impeller ■
Areas of application ■
Apartment housing �
Smaller commercial objects with a �
large waste water volumeFor waste water with long-fibre �
contentsBehind the grease separator up to �
NS 10Stainless steel collector tank, material ■
grade 316With drain plug ■
With connection for the manual membra- ■
ne pump R 1½“With mounting set for buoyancy safety ■
anchoringChoice of revision opening or inlet ■
socket
With 2 revision openings diameter: �
285 mm or with horizontal inlet socket DN 100/DN 150
Ventilation socket DN 100 for connec- ■
tion to the plastic pipePressure pipe connection ■
Via 2 special backflow valves DN 80 �
with short-spell ventilationWith an integrated special mounting �
piece for connection of the pressure pipe with an external diameter of 108 – 114 .3 mm
2 pump units ■
Motor 400 V, 50 Hz �
Protection category IP 68 �
With shaft and mechanical seal �
With free flow impeller �
Pneumatic level switching with pilot tube ■
and pneumatic control lineSeparate pilot tube for high alarm ■
Mini compressor for air bubble injection ■
Switching and warning device ■
Protection category IP 54 �
With 1 .5 m cable and CEE plug �
With dry contact centralised fault �
signal and operating signalInc . 4 m cabling between the lifting �
plant and control box
Ordering information
switch box plug-in ready(250 x 195 x 100)
cable 1.5 m long withCEKON-plug 16 A
connectionpneumatic control cable
motor cable(4m long) connection
mini compressor
connectionpneumatic control cable"ALARM 1"
connection forpotential-freecentralised alarm signalsand operation signals
connection for emergency power supplies
mini compressorfor air bubble injection
special fastening pieceDN 80/100
Y-branch ductDN 80/80/80
special backflow valveDN 80 with draining screw
stop valve DN 80 -accessories-
pressure pipe DN 100
Ø108 bis 114,3
free flow pumpgrain size 80 mm
1026
563
8 688
ca. 1
475
750
maintenance opening Rd 185one or more inlet DN 100 or DN 150right, left or on both sides
ventilation DN100
300 12
5
1000
275
10
333
160 160
inlet DN 100clamping flange
drain plug R 1 ½and attachment for manual membrane pump
1000
48
125
260
180
270
160
643
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water containing faeces
Remark: Maximum temperature of wastewater is only allowed for a short time .
Infobox
Type Motor ra-ting
Characteristics Grain size
Total volume
Useable volume
Weight Article No.
P1 P2 Current con-
sumpti-on
Voltage Frequen-cy
Inlet from above
[kW] [kW] [A] [V] [Hz] [mm] [l] [l] [kg]Muli Pro 1 .1
VA duo 2,01 1,5 4,1 400 50 80 270 155 210 0175.06.69
Muli Pro 1 .2 VA duo 2,94 2,2 5,2 400 50 80 270 155 215 0175.06.70
Muli Pro 1 .3 VA duo 3,87 3 7,2 400 50 80 270 155 225 0175.06.71
Muli Pro 1 .4 VA duo 5,1 4 10,3 400 50 80 270 155 230 0175.06.72
Performance parameters
Leistungsdiagramm Toleranzen ISO 2548/C17161514131211109876543210
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
0 5 10 15 20 25 30 35 40 45 50 55 60 65
Min
dest
förd
erst
rom
DN
80
Min
dest
förd
erst
rom
DN
100
[m]
[l/s]
[m³/h]
Förderstrom Q
Ges
amtfö
rder
höhe
H MULI-PRO-1.3 VA-duo
MULI-PRO-1.4 VA-duo
MULI-PRO-1.2 VA-duoMULI-PRO-1.1 VA-duo
Type Delive-ry head
Delivery flow Q with total delivery head H Conveyance media tem-perature
4 m 6 m 8 m 10 m 12 m Normal Maximum[m] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]
Muli Pro 1 .1 VA duo 3 – 6 11,0 3,1 40 60
Muli Pro 1 .2 VA duo 5 – 7 7,8 40 60
Muli Pro 1 .3 VA duo 6 – 10 13,15 9,4 4,35 40 60
Muli Pro 1 .4 VA duo 8 – 12 13,1 9,6 4,7 40 60
644
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water containing faeces
Muli Pro 2.x VA duo
Product information
ACO product advantages
Forced activation upon „level high“ ■
ensures high operating securitySuitable for fatty waste water ■
Pilot tube and air bubble injection ■
ensure high operating safetyBlockage-free free flow impeller ■
Areas of application ■
Apartment housing �
Behind the grease separator up to �
NS 20For municipal and industrial waste �
waterStainless steel collector tank, material ■
grade 316With drain plug ■
With connection for the manual membra- ■
ne pump R 1½“With mounting set for buoyancy safety ■
anchoringChoice of revision opening or inlet ■
socket
With 2 revision openings diameter: �
285 mm or with horizontal inlet socket DN 100/DN 150
Ventilation socket DN 100 for connec- ■
tion to the plastic pipePressure pipe connection ■
Via 2 special backflow valves DN 80 �
with short-spell ventilationWith an integrated special mounting �
piece for connection of the pressure pipe with an external diameter of 108 – 114 .3 mm
2 pump units ■
Motor 400 V, 50 Hz �
Protection category IP 68 �
With shaft and mechanical seal �
With free flow impeller �
Pneumatic level switching with pilot tube ■
and pneumatic control lineSeparate pilot tube for high alarm ■
Mini compressor for air bubble injection ■
Switching and warning device ■
Protection category IP 54 �
With 1 .5 m cable and CEE plug �
With dry contact centralised fault �
signal and operating signalInc . 4 m cabling between the lifting �
plant and control box
Ordering information
mini compressor for air bubble injection
drain plug R 1 ½ and attachment for manual membrane pump
260
180
270
160
1000
48
inlet DN 100 clamping flange125
special fastening pieceDN 80/100Y-branch ductDN 80/80/80
special backflow valveDN 80 with draining screw
stop valveDN 80 -accessories-
on both sides - inlet clamping flange DN 150(blindly locked)
pressure pipe DN 100
Ø108 up to 114,3
free flow pump grain size 80 mm
988
ca. 1
600
750
10
265
83093
8
300 12
5
1000
275
10
160 160
500
333
maintenance opening Rd 185one or moreinlet DN 100 or DN 150right, left or on both side
ventilation DN100
switch box plug-in ready(250 x 195 x 100)
cable 1.5 m long withCEKON-plug 16 A
connectionpneumatic control cable
motor cable(4m long) connection
mini compressor
connectionpneumatic control cable"ALARM 1"
connection forpotential-freecentralised alarm signalsand operation signals
connection foremergency power supplies
645
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water containing faeces
Remark: Maximum temperature of wastewater is only allowed for a short time .
Infobox
Type Motor ra-ting
Characteristics Grain size
Total volume
Useable volume Weight Article No.
P1 P2 Current con-
sumpti-on
Voltage Fre-quency
Inlet height
Z1
Inlet from above
[kW] [kW] [A] [V] [Hz] [mm] [l] [l] [l] [kg]Muli Pro 2 .1
VA duo 2,01 1,5 4,1 400 50 80 365 185 245 290 0175.06.74
Muli Pro 2 .2 VA duo 2,94 2,2 5,2 400 50 80 365 185 245 295 0175.06.75
Muli Pro 2 .3 VA duo 3,87 3 7,2 400 50 80 365 185 245 305 0175.06.76
Muli Pro 2 .4 VA duo 5,1 4 10,3 400 50 80 365 185 245 310 0175.06.77
Performance parameters
Leistungsdiagramm Toleranzen ISO 2548/C17161514131211109876543210
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
0 5 10 15 20 25 30 35 40 45 50 55 60 65
Min
dest
förd
erst
rom
DN
80
Min
dest
förd
erst
rom
DN
100
[m]
[l/s]
[m³/h]
Förderstrom Q
Ges
amtfö
rder
höhe
H MULI-PRO-2.3 VA-duo
MULI-PRO-2.4 VA-duo
MULI-PRO-2.2 VA-duoMULI-PRO-2.1 VA-duo
Type Delive-ry head
Delivery flow Q with total delivery head H Conveyance media tem-perature
4 m 6 m 8 m 10 m 12 m Normal Maximum[m] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]
Muli Pro 2 .1 VA duo 3 – 6 11,0 3,1 40 60
Muli Pro 2 .2 VA duo 5 – 7 7,8 40 60
Muli Pro 2 .3 VA duo 6 – 10 13,15 9,4 4,35 40 60
Muli Pro 2 .4 VA duo 8 – 12 13,1 9,6 4,7 40 60
646
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water containing faeces
Accessories
Designation compatible with Description Article No.
Ø12
0Ø
110
15
Ø13
380
176
140
10 Inlet valve DN 100Waste water lifting plants ■
Polyethylene grease separator ■
Polyethylene starch separator ■
PVC ■
Construction length: 176 mm ■
Weight: 2 .75 kg ■
0175.13.84
Ø17
4Ø
160
Ø18
610
8
226
1512
Inlet valve DN 150Waste water lifting plants ■
Polyethylene grease separator ■
Polyethylene starch separator ■
PVC ■
Construction length: 226 mm ■
Weight: 6 .5 kg ■
0175.13.85
Ø160
180
315
Stop valve DN 80 Waste water lifting plants ■
Cast iron ■
For pressure pipe ■
Construction length: 180 mm ■
Weight: 21 kg ■
0159.09.89
Ø200
190
345
Stop valve DN 100 Waste water lifting plants ■
Cast iron ■
For pressure pipe ■
Construction length: 190 mm ■
Weight: 32 kg ■
0159.09.90
Fastening parts kit Stop valve ■
0159 .09 .89 �8 screws and nuts ■
1 sealing ■0159.00.19
Fastening parts kit Stop valve ■
0159 .09 .90 �8 screws and nuts ■
1 sealing ■0159.00.20
Ø70
55
123
R 1
½“
Stop valve R 1½“ Waste water lifting plants ■For the manual membrane ■
pump 0159.10.12
Ø160
180
315
Stop valve DN 80 Muli-Star MDS1/MWS1 ■
Cast iron ■
8 screws and nuts ■
1 sealing DN 80 ■
Construction length: 180 mm ■
Weight: 21 kg ■
0154.51.93
647
Was
te w
ater
lif
tin
g p
lan
tsW
aste
wat
er co
nta
inin
g fa
eces
14
K9/1
Waste water lifting plant for free-standing installationMuli-Series
Pumps Waste water lifting plants Waste water containing faeces
Designation compatible with Description Article No.
Hupe„AUS“
Störung
Test
Summer
116 (60 T)
116
Signal device (network dependent)
Automatic faeces backflow ■
systems Quatrix-K Type 3FSinkamat-S/-Z ■
Muli polyethylene duo ■
Muli polyethylene S mono/duo ■
All Multi-Pro waste water lifting ■
plantsSuspension plant mono/duo ■
Visual and acoustic ■
Network dependent ■
Without pickup ■
With dry contact for fault signal ■
levelWith 1 m connecting cable and ■
angled three-wire plug
0159.12.30
Hupe„AUS“
Störung
Test
Summer
116 (60 T)
116
Signal device (network independent)
Automatic faeces backflow ■
systems Quatrix-K Type 3FSinkamat-S/-Z ■
Muli polyethylene S mono/duo ■
All Multi-Pro waste water lifting ■
plantsSuspension plant mono/duo ■
Visual and acoustic ■
Self-charging ■
Without pickup ■
With dry contact for fault signal ■
levelWith acoustic deletion ■
With 1 m connecting cable and ■
angled three-wire plug
0159.12.31
Air bubble injection for level switching
Muli polyethylene S mono/duo ■
Muli polyethylene duo ■
For increased operation safety ■
when using float cover develop-ment (e .g . grease separator)Pilot tube with mini compressor ■
230 V
Mono plant 0159.00.47
Duo plant 0159.00.48
430
240 225
90
470
Manual membrane pump R 1½“ Waste water lifting plants ■
For wall mounting ■
Inc . hose ■
Clear diameter: 48 x 80 mm �Inc . hose clips ■
Clear diameter: 50 x 70 mm �Width: 12 mm �2 pieces required �
0175.23.73
Rp 1 1/2
Three-way stopcock R 1½“ Waste water lifting plants ■
For the manual membrane ■
pump 0159.10.14
45Ø
70
17065
Horn Alarm device with dry contact ■
for fault signal230 V ■
Height: 78 mm ■0178.61.94
110139
Ø90
Ø10
0
Flashing light Alarm device with dry contact ■
for fault signal 230 V ■ 0178.62.08
DN
45
Ø265Ø285
(mon
tiert) Inlet socket Muli-Pro VA ■
For lateral inlet to waste water ■
lifting plant
DN 100 0175.07.58
DN 150 0175.07.61
O-ring Fäkablock II ■
Muli series ■
As additional components for ■
the pressure pipe DN 80 0159.37.97