SUMMARY , DURING INSPECTION OF CHEMICAL INJECTION NOZZLE INSTALLATION INSPECTION AT UTILITY , ON 27 AUGUST 2014 COMMENTS REMARKS 1 SP-338 313 20 X 3 283 332 INSTALLED 291 294.5 2 SP-337 313 20 X 3 283 332 INSTALLED 291 294.5 3 SP-336 313 20 X 3 283 332 INSTALLED 291 289.5 4 SP-332 341 50 X 5 265 358 INSTALLED 287 289 5 SP-330 410 50 X 5 341 470 INSTALLED 366 259.5 6 SP-329 410 50 X 5 341 470 INSTALLED 363 364.5 7 SP-328 410 50 X 5 341 470 INSTALLED 365 357.5 8 SP-331 410 50 X 5 341 470 INSTALLED 362 359.5 9 SP-326 440 50 X 5 370 520 INSTALLED 391 383.5 10 SP-333 333 20 X 3 300 360 INSTALLED 309 307.1 11 SP-327 342 50 X 5 267 360 290 310 12 SP-335 560 50 X 5 485 690 507 446 13 SP-334 335 20 X 3 300 360 307 314.14 SL NO SPECIAL COMMODTY NO FLOW DIRECTION SLOT OEIENTATION LENGTH: FLANGE BOTTOM TO CLOSED END(mm) SLOT SIZE: LENGTH x WIDTH(mm) LENGTH:FLANGE END BOTTOM TO TOP OF SLOT(mm) LENGTH:FLANGE TOP TO BOTTOM OF PIPE(mm) (INSIDE PIPE) LENGTH:ACTUAL QUILL DIMENSION (L) VALUE IN mm LENGTH:FLANGE TOP TO CENTRE OF THE HEADER LINE IN mm DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION 1) PICKLING TO BE DONE 2) PMI TO BE DONE DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION 1) TEMPORARY GASKET FOUND ON FLANGE JOINT , FLANGE FACE SHOULD BE CLEANED PRIOR TO INSTALLATION DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION 1) TEMPORARY GASKET FOUND ON FLANGE JOINT , FLANGE FACE SHOULD BE CLEANED PRIOR TO INSTALLATION DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION 1) TEMPORARY GASKET FOUND ON FLANGE JOINT , FLANGE FACE SHOULD BE CLEANED PRIOR TO INSTALLATION 2)BOTTOM OF CLOSED END TO BE CLEANED. DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION 1) TEMPORARY GASKET FOUND ON FLANGE JOINT , FLANGE FACE SHOULD BE CLEANED PRIOR TO INSTALLATION DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION 1) TEMPORARY GASKET FOUND ON FLANGE JOINT , FLANGE FACE SHOULD BE CLEANED PRIOR TO INSTALLATION 2) MECHANICAL MARKING FOUND ON QUILL BODY DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION 1) TEMPORARY GASKET FOUND ON FLANGE JOINT , FLANGE FACE SHOULD BE CLEANED PRIOR TO INSTALLATION 2) MECHANICAL MARKING FOUND ON QUILL BODY DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION 1) TEMPORARY GASKET FOUND ON FLANGE JOINT , FLANGE FACE SHOULD BE CLEANED PRIOR TO INSTALLATION 2) REQUIRED PIKOTEK GASKETS 1) FBE COATING REPAIRED ATTACH , REPAIR REPORT 2)INSTALLED WITH SPIRAL WOUND GASKET DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION 1) TEMPORARY GASKET FOUND ON FLANGE JOINT , FLANGE FACE SHOULD BE CLEANED PRIOR TO INSTALLATION 2) REQUIRED PIKOTEK GASKETS 1)INSTALLED WITH SPIRAL WOUND GASKET DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION 1) REQUIRED PIKOTEK GASKETS 1)INSTALLED WITH SPIRAL WOUND GASKET

Chemical Injection Quil

Embed Size (px)

DESCRIPTION

jzchkLCJ

Citation preview

Sheet1SUMMARY , DURING INSPECTION OF CHEMICAL INJECTION NOZZLE INSTALLATION INSPECTION AT UTILITY , ON 27 AUGUST 2014

SL NOSPECIAL COMMODTY NOFLOW DIRECTIONSLOT OEIENTATIONLENGTH: FLANGE BOTTOM TO CLOSED END(mm)SLOT SIZE: LENGTH x WIDTH(mm)LENGTH:FLANGE END BOTTOM TO TOP OF SLOT(mm)LENGTH:FLANGE TOP TO BOTTOM OF PIPE(mm)(INSIDE PIPE)COMMENTSREMARKSLENGTH:ACTUAL QUILL DIMENSION (L) VALUE IN mmLENGTH:FLANGE TOP TO CENTRE OF THE HEADER LINE IN mm1SP-338DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION31320 X 3283332INSTALLED291294.52SP-337DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION31320 X 32833321) PICKLING TO BE DONE2) PMI TO BE DONEINSTALLED291294.53SP-336DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION31320 X 3283332INSTALLED291289.54SP-332DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION34150 X 52653581) TEMPORARY GASKET FOUND ON FLANGE JOINT , FLANGE FACE SHOULD BE CLEANED PRIOR TO INSTALLATIONINSTALLED2872895SP-330DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION41050 X 53414701) TEMPORARY GASKET FOUND ON FLANGE JOINT , FLANGE FACE SHOULD BE CLEANED PRIOR TO INSTALLATIONINSTALLED366259.56SP-329DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION41050 X 53414701) TEMPORARY GASKET FOUND ON FLANGE JOINT , FLANGE FACE SHOULD BE CLEANED PRIOR TO INSTALLATION2)BOTTOM OF CLOSED END TO BE CLEANED.INSTALLED363364.57SP-328DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION41050 X 53414701) TEMPORARY GASKET FOUND ON FLANGE JOINT , FLANGE FACE SHOULD BE CLEANED PRIOR TO INSTALLATIONINSTALLED365357.58SP-331DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION41050 X 53414701) TEMPORARY GASKET FOUND ON FLANGE JOINT , FLANGE FACE SHOULD BE CLEANED PRIOR TO INSTALLATION2) MECHANICAL MARKING FOUND ON QUILL BODYINSTALLED362359.59SP-326DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION44050 X 5370520INSTALLED391383.510SP-333DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION33320 X 33003601) TEMPORARY GASKET FOUND ON FLANGE JOINT , FLANGE FACE SHOULD BE CLEANED PRIOR TO INSTALLATION2) MECHANICAL MARKING FOUND ON QUILL BODYINSTALLED309307.111SP-327DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION34250 X 52673601) TEMPORARY GASKET FOUND ON FLANGE JOINT , FLANGE FACE SHOULD BE CLEANED PRIOR TO INSTALLATION2) REQUIRED PIKOTEK GASKETS1) FBE COATING REPAIRED ATTACH , REPAIR REPORT2)INSTALLED WITH SPIRAL WOUND GASKET29031012SP-335DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION56050 X 54856901) TEMPORARY GASKET FOUND ON FLANGE JOINT , FLANGE FACE SHOULD BE CLEANED PRIOR TO INSTALLATION2) REQUIRED PIKOTEK GASKETS1)INSTALLED WITH SPIRAL WOUND GASKET50744613SP-334DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION33520 X 33003601) REQUIRED PIKOTEK GASKETS1)INSTALLED WITH SPIRAL WOUND GASKET307314.140

Sheet2

Sheet3