Upload
sameer313
View
213
Download
0
Embed Size (px)
DESCRIPTION
jzchkLCJ
Citation preview
Sheet1SUMMARY , DURING INSPECTION OF CHEMICAL INJECTION NOZZLE INSTALLATION INSPECTION AT UTILITY , ON 27 AUGUST 2014
SL NOSPECIAL COMMODTY NOFLOW DIRECTIONSLOT OEIENTATIONLENGTH: FLANGE BOTTOM TO CLOSED END(mm)SLOT SIZE: LENGTH x WIDTH(mm)LENGTH:FLANGE END BOTTOM TO TOP OF SLOT(mm)LENGTH:FLANGE TOP TO BOTTOM OF PIPE(mm)(INSIDE PIPE)COMMENTSREMARKSLENGTH:ACTUAL QUILL DIMENSION (L) VALUE IN mmLENGTH:FLANGE TOP TO CENTRE OF THE HEADER LINE IN mm1SP-338DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION31320 X 3283332INSTALLED291294.52SP-337DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION31320 X 32833321) PICKLING TO BE DONE2) PMI TO BE DONEINSTALLED291294.53SP-336DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION31320 X 3283332INSTALLED291289.54SP-332DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION34150 X 52653581) TEMPORARY GASKET FOUND ON FLANGE JOINT , FLANGE FACE SHOULD BE CLEANED PRIOR TO INSTALLATIONINSTALLED2872895SP-330DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION41050 X 53414701) TEMPORARY GASKET FOUND ON FLANGE JOINT , FLANGE FACE SHOULD BE CLEANED PRIOR TO INSTALLATIONINSTALLED366259.56SP-329DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION41050 X 53414701) TEMPORARY GASKET FOUND ON FLANGE JOINT , FLANGE FACE SHOULD BE CLEANED PRIOR TO INSTALLATION2)BOTTOM OF CLOSED END TO BE CLEANED.INSTALLED363364.57SP-328DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION41050 X 53414701) TEMPORARY GASKET FOUND ON FLANGE JOINT , FLANGE FACE SHOULD BE CLEANED PRIOR TO INSTALLATIONINSTALLED365357.58SP-331DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION41050 X 53414701) TEMPORARY GASKET FOUND ON FLANGE JOINT , FLANGE FACE SHOULD BE CLEANED PRIOR TO INSTALLATION2) MECHANICAL MARKING FOUND ON QUILL BODYINSTALLED362359.59SP-326DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION44050 X 5370520INSTALLED391383.510SP-333DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION33320 X 33003601) TEMPORARY GASKET FOUND ON FLANGE JOINT , FLANGE FACE SHOULD BE CLEANED PRIOR TO INSTALLATION2) MECHANICAL MARKING FOUND ON QUILL BODYINSTALLED309307.111SP-327DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION34250 X 52673601) TEMPORARY GASKET FOUND ON FLANGE JOINT , FLANGE FACE SHOULD BE CLEANED PRIOR TO INSTALLATION2) REQUIRED PIKOTEK GASKETS1) FBE COATING REPAIRED ATTACH , REPAIR REPORT2)INSTALLED WITH SPIRAL WOUND GASKET29031012SP-335DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION56050 X 54856901) TEMPORARY GASKET FOUND ON FLANGE JOINT , FLANGE FACE SHOULD BE CLEANED PRIOR TO INSTALLATION2) REQUIRED PIKOTEK GASKETS1)INSTALLED WITH SPIRAL WOUND GASKET50744613SP-334DOWN STREAM SIDE OF INJECTION COIL WITH RESPECT TO FLOW DIRECTION33520 X 33003601) REQUIRED PIKOTEK GASKETS1)INSTALLED WITH SPIRAL WOUND GASKET307314.140
Sheet2
Sheet3