FINAL REPORT Evaluation of Water Quality Data Chester Water Department, Chester MA Prepared by: Richard W. Gullick, PhD RCAP Solutions, Inc. June 27, 2019 Table of Contents: 1. Introduction and Objectives 2. Treatment System 3. Methodology 4. Drinking Water Production 5. Filtration 6. Primary Disinfection 7. Secondary Disinfection (Distribution System Chlorine Residual) 8. pH 9. Disinfection Byproducts 10. Color 11. Lead and Copper 12. Summary and Conclusions 13. Recommendations 1. Introduction and Objectives: The Chester Water Department operates a community water supply system (PWSID 1059000) that serves approximately 750 people through approximately 252 connections in this small town located in western Massachusetts. The water system recently exceeded the allowable Maximum Contaminant Level (MCL) for the disinfection byproduct (DBP) class known as total trihalomethanes (TTHMs) for three quarters in a row – the third and fourth quarter of 2018 and the first quarter of 2019. The Massachusetts Department of Environmental Protection (MassDEP) issued a Notice of Noncompliance (Enforcement Number 00005564) to Chester on December 4, 2018 for the third quarter 2018 TTHM MCL exceedance, and a Notice of Noncompliance (Enforcement Number 00006424) to Chester on May 3, 2019 for the fourth

Chester data evaluation report FINAL 6-27-19€¦ · FINAL REPORT Evaluation of Water Quality Data Chester Water Department, Chester MA Prepared by: Richard W. Gullick, PhD RCAP Solutions,

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Chester data evaluation report FINAL 6-27-19€¦ · FINAL REPORT Evaluation of Water Quality Data Chester Water Department, Chester MA Prepared by: Richard W. Gullick, PhD RCAP Solutions,

FINALREPORT

EvaluationofWaterQualityDataChesterWaterDepartment,ChesterMA

Preparedby:

RichardW.Gullick,PhDRCAPSolutions,Inc.

June27,2019TableofContents:

1. IntroductionandObjectives2. TreatmentSystem3. Methodology4. DrinkingWaterProduction5. Filtration6. PrimaryDisinfection7. SecondaryDisinfection(DistributionSystemChlorineResidual)8. pH9. DisinfectionByproducts10. Color11. LeadandCopper12. SummaryandConclusions13. Recommendations

1.IntroductionandObjectives:TheChesterWaterDepartmentoperatesacommunitywatersupplysystem(PWSID1059000)thatservesapproximately750peoplethroughapproximately252connectionsinthissmalltownlocatedinwesternMassachusetts.ThewatersystemrecentlyexceededtheallowableMaximumContaminantLevel(MCL)forthedisinfectionbyproduct(DBP)classknownastotaltrihalomethanes(TTHMs)forthreequartersinarow–thethirdandfourthquarterof2018andthefirstquarterof2019.TheMassachusettsDepartmentofEnvironmentalProtection(MassDEP)issuedaNoticeofNoncompliance(EnforcementNumber00005564)toChesteronDecember4,2018forthethirdquarter2018TTHMMCLexceedance,andaNoticeofNoncompliance(EnforcementNumber00006424)toChesteronMay3,2019forthefourth

Page 2: Chester data evaluation report FINAL 6-27-19€¦ · FINAL REPORT Evaluation of Water Quality Data Chester Water Department, Chester MA Prepared by: Richard W. Gullick, PhD RCAP Solutions,

Page 2 of 22

quarter2018andfirstquarter2019TTHMMCLexceedances.ChesterwasalsorequiredtocompleteandsubmitanOperationalEvaluationReportforexceedingtheOperationalEvaluationLevel(OEL)limitforTTHMinthesecondandthirdquartersof2018(perMassDEPletterdatedDecember4,2018).Inaddition,inaletterdatedAugust24,2018,MassDEPrequiredChesterto“prepareawrittenreporttoaddressthe2018color,turbidity,sourcewaterquality,anddisinfectionbyproductconcerns.”Thisreportpresentsthefindings,conclusions,andrecommendationsfromanevaluationofavailablewaterqualitydata,andisintendedtohelpsatisfytheaboveMassDEPrequirements.Thisevaluationincludesthewaterqualityparameterslistedabove,aswellasobservationsandrecommendationsrelatedtootheroperationaltopics.2.TreatmentSystem:Chester’swatertreatmentsystemiscomprisedmainlyofthefollowing,intheorderpresented:

1. PresentlythesourcewaterisfromHornPond,withtheAustinBrookReservoirservingasanalternatebackupsupply.

2. Slowsandfiltration–threeslowsandfiltersareavailable,andoneincludesalayerofgranularactivatedcarbonforremovingnaturalorganicmatter(NOM),whichisaprecursortoDBPformation.

3. Disinfectionwithfreechlorine–thisisaccomplishedinthethirdsegmentoftheclearwell(thewholeclearwellisavoidedtoreducechlorinecontacttimeandthusreduceDBPformation).

4. pHadjustmentusingsodiumhydroxide(NaOH),injectedjustaftertheclearwellandbeforethewaterleavesthetreatmentplant.

5. Disinfectionwithfreechlorine–thissecondstageofprimarydisinfectionisaccomplishedinthe~1,800-footpipelineleadingfromthetreatmentplantdownthehilltotheoldchlorinatorbuilding.ChorineisaddedatthetreatmentplantjustaftertheNaOHaddition,andtheresidualismeasuredattheoldchlorinatorbuilding.Enoughchlorineresidualistargetedtomaintainaresidualinthedistributionsystem(i.e.,secondarydisinfection).Forchlorinedisinfection,thepipelinehastheadvantageofahigherbafflingfactorthantheclearwell(1.0versus0.13,respectively),butthedisadvantageofahigherpH.

6. TheoldchlorinatorbuildingisconsideredtobethePointofEntry(POE)tothedistributionsystem.FinishedwaterturbidityandpHarealsomeasuredattheoldchlorinatorbuilding.

3.Methodology:Availablewaterproductionandwaterqualitydatawerereviewedforcalendaryear2018.MostofthedatawereobtainedfromtheMonthlyOperatingReports(MORs)thataresubmittedtotheMassDEP.TheMORswereobtainedfromtheChesterWaterDepartment.Flowandwaterqualitydatawereplottedtoidentifytrends,variousdatasetswerecomparedtoidentifypotentialcorrelations,andresultswerecomparedtothecorrespondingregulatoryrequirements(e.g.,MCLs)orotherwaterqualitytargets.Inaddition,adistributionsystemchlorineresidualmappingexercisewasconductedonMarch27,2019.

Page 3: Chester data evaluation report FINAL 6-27-19€¦ · FINAL REPORT Evaluation of Water Quality Data Chester Water Department, Chester MA Prepared by: Richard W. Gullick, PhD RCAP Solutions,

Page 3 of 22

4.DrinkingWaterProduction:Thequantityofpotablewaterproducedeachdayin2018ispresentedinFigure1.ThereportedpeakhourlyflowsforeachdayarepresentedinFigure2.

Figure1.Potablewaterproducedperday(1/1/18–12/31/18)

Figure2.PeakHourlyFlowforeachday(1/1/18–12/31/18)

Page 4: Chester data evaluation report FINAL 6-27-19€¦ · FINAL REPORT Evaluation of Water Quality Data Chester Water Department, Chester MA Prepared by: Richard W. Gullick, PhD RCAP Solutions,

Page 4 of 22

Thefollowingobservationsareevidentfromthewaterproductiondata:

• In2018,dailyflowsaveraged45,691gpd.Thehighestdailyflowwas109,328gpd,andthelowestdailyflowwas32,672gpd.

• Assumingapopulationsizeof750people,theaverageproductioncorrespondsto61gpdperperson,whichisveryclosetothenationalaverageof58.6gallonspercapitaperdayforresidentialcommunities(DeOreoetal.,2016).

• In2018,peakhourlyflowsaveraged49gpm.Thehighestpeakhourlyflowwas129gpm,andthelowestpeakhourlyflowwas32gpm.

• Theratioofaveragepeakhourlyflowtoannualaverageflowis1.5(49gpmvs.31.7gpm).• Thereweresomeperiodsofabnormallyhighflow,includinglateJanuary–earlyFebruary,and

againinOctoberandthenNovember(Figure1).Theselargeincreasesinwaterproductionappearattributabletoleakingpipesthatwerediscoveredandrepaired.Forexample,theJanuary/FebruaryissuewasapipebreakonEmeryStreetthatfilledabasement.

• Chesterusesthemeasuredvalueofpeakhourlyflowfordeterminingdisinfectionperformance,insteadofthealternatemethodofassumingavalueforpeakhourlyflowbasedontheaverageannualflowandapeakingfactor.Atypicalpeakingfactorusedis3.0,whileChester’smeasuredpeakingfactorisonly1.5.ItisrecommendedthatChestercontinuetousethemeasuredpeakhourlyflowinsteadofusingthealternatepeakingfactormethod,asinthiscasethatwouldtypicallyresultinlessdisinfectionbeingrequiredthanviathepeakingfactorapproach.Thiswouldbedisadvantageousonlyincircumstanceswherethereisanabnormalamountofflow,suchasduringamainbreak.

• Nounresolvedissueswereidentifiedregardingthewaterproductiondata.5.Filtration:TheChesterWaterDepartmentusesslowsandfiltrationaspartofthetreatmentsystem.Therearethreefilters,oneofwhich(Filter#3)hasagranularactivatedcarbon(GAC)layerbetweentwosandlayers(a“carbonsandwich”)forremovingnaturalorganicmatter(NOM),whichisaprecursortoDBPformation.Anywherefromonetothreefiltersmaybeoperatingatagiventime,dependingonflowrequirementsandimpactsfromfilterheadloss.DuringtheMarch27,2019sitevisit,Filter#2wastheonlyfilterinoperation.Turbidityhasbeenmonitoredforthefinishedwater,butnotforthecombinedfiltereffluent.TheturbiditymeteriscalibratedtwiceperyearbythesystemOperator(typicallyaroundJune1andduringtheDecemberholidays).

Forslowsandfiltration,theregulatoryrequirementsincludethefollowingtwoconditions(per310CMR22.20A(4)(b):

1. Atleast95%oftheCombinedFilterEffluent(CFE)turbidityreadingsinagivencalendarmonthmustbe≤1NTU(Nephelometricturbidityunit).Giventhatonlyonesignificantdigitisusedforthatlimit,thedatashouldalsoberoundedtoonesignificantdigit.Thismeansthatavalueof1.49NTUwouldberoundeddownto1NTU,andthatwouldmeetthelimit.Avalueof1.50NTUwouldberoundedupto2NTU,andthatwouldexceedtheallowablelimit.

Page 5: Chester data evaluation report FINAL 6-27-19€¦ · FINAL REPORT Evaluation of Water Quality Data Chester Water Department, Chester MA Prepared by: Richard W. Gullick, PhD RCAP Solutions,

Page 5 of 22

2. AtnotimecantheCombinedFilterEffluentturbiditybeabove5NTU(thusallowingupto5.49NTU,butnot5.50NTU).

Thefinishedwaterturbidityfor2018isplottedinFigure3(resultswerenotavailablefortheCombinedFilterEffluent).Thefollowingobservationsweremaderegardingthefiltrationoperations:

Figure3.FinishedWaterTurbidity

• Therequiredturbiditylimitsweremetthroughout2018.Theaveragedailyvaluefor2018was0.11NTU,andthehighestdailyvaluewas0.29NTU.Assuch,therewerenoresultsneareitherthe95%limitof≤1NTUnortheabsolutelimitof≤5NTU.

• Chesterhasbeencollectingthesamplesfortheturbidityanalysesfromthetreatmentplantfinishedwater(PointofEntry,orPOE).However,theproperlocationforsamplingturbidityforregulatorycomplianceisthecombinedfiltereffluentwater,beforeanyfurthertreatmentorchemicaladdition(referredtoas“filteredwater”in310CMR22.20A(4)(b)).Typically,filtereffluentturbiditiesarelowerthanfinishedwaterturbidities.RaisingthepHofthewatercancausedissolvedmetalstoprecipitateandthusincreasetheturbidity.Thefiltereffluentturbidityvaluesshouldbeusedforregulatorycompliancereporting,andforassessingtheoperationoftheslowsandfilters.

Chester’sOperatorreportedthattypicallythefiltereffluentturbiditiesarearound0.03to0.04NTU,asopposedtotheaveragedailyfinishedwaterturbidityof0.11NTU.WhencheckedonMarch27,2019,thefilteredwaterturbiditywas0.02NTUandthefinishedwaterturbiditywas0.09NTU.

• Chestershouldinstallsampletapsforallthreeindividualfiltereffluents(IFEs)andalsotheonecombinedfiltereffluent(CFE).ThereshouldbeanonlineturbiditymeterfortheCFEsample,andthatwouldbeusedfordeterminingthemaximumturbidityvalueforeachday.

Page 6: Chester data evaluation report FINAL 6-27-19€¦ · FINAL REPORT Evaluation of Water Quality Data Chester Water Department, Chester MA Prepared by: Richard W. Gullick, PhD RCAP Solutions,

Page 6 of 22

• TherewasanincreaseinfinishedwaterturbidityinAugust2018,andthenasecondspikeoccurredforalittleoveraweekinSept2018.However,themaximumturbiditywas0.29NTU,whichiswellbelowtheregulatorylimit=.Therefore,whiletheseturbidityincreasesarenotableforoperationalpurposes,thereisnoconcernrelatedtotheregulatoryrequirementsforturbidity.Thesystemoperatordoesnotbelievethatsourcewaterqualitywasacauseoftheincreasesinturbidity,andwonderedifafilterwasperhapsbroughtonlinepriortoitbeingcompletelyripened.

Theturbiditydatashowthefollowing(Figure3):• TurbiditystartedtoincreaseonJuly31,2018,reachedamaximumonAugust16-

17,2018,andthenstarteddecreasinguntilitreachednormallevelsaroundtheendofAugust2018.

• TurbiditystartedincreasingagainonSeptember6,2018,reachingamaximumonSeptember15,andwasthenbackdowntonormalbyaboutOctober1.

AnexcerptoftheOperator’slogbookforthattimeperiodisprovidedasFigure4.Itispossiblethatthefirstturbidityspikeiscorrelated,atleastinpart,toFilter#3beingtakenoffline.ThesecondspikestartsnotlongbeforeFilter#1wastakenofflinetodrainforcleaning,andpeakedonSeptember15,onlytwodaysbeforeFilter#1camebackonlineonSept.17.

Inthefuture,anyincreaseinturbidityshouldbeinvestigatedatthetimeitoccurs.ItisnotreadilyevidentfromtheOperator’sLogwhichfiltersareonlineatagiventime,thoughitappearsthatallthreewereonlinepriortothefirstturbidityspikethatstartedonJuly31,2018.Itmaybehelpfultotracksomewhatdifferentlywhichfiltersareonline.Figure5providesasampletemplateforatabletodothat,whichwouldmakeitsomewhateasierinthefuturetotryandcorrelatefilteroperationswithturbidityspikes.

Figure4.ExcerptfromOperator’sLogbook

Day Date Filter#1 Filter#2 Filter#3

?? ?? ONLINE ONLINE ONLINE

?? ?? takenOFFLINEat9:15am;drainingforcleaning

?? ?? PutbackONLINEat11:30am

?? ?? takenOFFLINEat9:15am;drainingforcleaning

?? ?? PutbackONLINEat9:30am

Figure5.SampleFilterOperationsLog

Page 7: Chester data evaluation report FINAL 6-27-19€¦ · FINAL REPORT Evaluation of Water Quality Data Chester Water Department, Chester MA Prepared by: Richard W. Gullick, PhD RCAP Solutions,

Page 7 of 22

6.PrimaryDisinfection:TheChesterWaterDepartmentusesfreechlorineforbothprimaryandsecondary(residual)disinfection.TheregulatoryrequirementsforprimarydisinfectionforthiswatersystemarebasedontheabilitytoinactivateGiardiacysts,andrequiresaminimumof1.0-logremoval(1.0log=90%removal,and2.0logs=99%removal).ThatremovalisafunctionofthepHandtemperatureofthewater,chlorineresidualconcentration,andchlorinecontacttime.Chester’streatmentplantusestwochlorinecontactchambersformeetingthedisinfectionrequirements.Thetargetchlorineresidualsareabout0.4to0.8mg/L.Therearetablesavailableinthetreatmentplantthatprovidesuggestedchlorineresidualsforavarietyofoperatingconditions(e.g.,differenttemperaturesandpH).NoattemptwasmadebyRCAPtoverifytheaccuracyofthatinformation.Thefinishedwaterchlorineresidualsfor2018areplottedinFigure6.

Figure6.FinishedWaterChlorineResidual

Thefollowingobservationsweremaderegardingthechemicaldisinfectionoperations:

• Therequireddisinfectionperformancewasmetatalltimesin2018.• Chlorineresidualsvarymorethanisdesiredformaintainingaconsistentwaterquality.Arange

of+/-0.2mg/Lor+/-0.3fromthetargetconcentrationwouldbeareasonablegoal.ItisrecommendedthatChesterinvestigatehowtomaintainamoreconsistentfinishedwaterchlorineresidual.

• Finishedwaterchlorineresidualwasconstantat0.3mg/LfromJuly11toAugust31,2018.ThesystemOperatorwasnotabletoprovideanexplanationforthisanomaly.

Page 8: Chester data evaluation report FINAL 6-27-19€¦ · FINAL REPORT Evaluation of Water Quality Data Chester Water Department, Chester MA Prepared by: Richard W. Gullick, PhD RCAP Solutions,

Page 8 of 22

• RCAP’scalculationoftheachieveddisinfectionperformancecalculationsconfirmedthatChesteriscalculatingdisinfectionperformanceaccurately(withinreasonablevariancesforroundingdifferences).However,thepartofthecalculationinvolvingthevolumeofthechlorinecontactorwasnotchecked.RCAPwasnotabletoobtainthespecificationsusedintheSCADAcalculationstodeterminethevolumeofthechlorinecontactors(partofdeterminingchlorinecontacttime),andthuscouldnotconfirmthisaccuracy.Itisrecommendedthatthisinformationbeobtainedandreviewedforaccuracy.

• Abafflingfactorof0.13isusedforthechlorinecontactchamber.ThesystemOperatornotesthatthiswasdeterminedviaatracerstudyconductedwithassistancefromtheMassachusettsRuralWaterAssociationandalsoMikeMcGrathofMassDEP.Nodocumentationofthistracerstudywasavailable.Thetracerstudyreportshouldbelocatedandfiled,andalsoperhapsbesubjecttoareview.RCAPSolutionsisavailabletoconductthatreviewifsodesiredbytheChesterWaterDepartment.

7.SecondaryDisinfection(DistributionSystemChlorineResidual):Secondary(residual)disinfectioninvolvesmaintainingadetectablechlorineresidualinthedistributionsystem.ThisismonitoredviathechlorineresidualanalysesconductedwhensamplingmonthlyforcoliformbacteriaaspartoftheRevisedTotalColiformRule(RTCR)monitoringprogram.Whiletheregulatoryrequirementisfora“detectable”chlorineresidual,ideallychlorineresidualsconcentrationsshouldbe≥0.2mg/Lthroughoutadistributionsystem.FortheChesterdistributionsystem,chlorineresidualiscurrentlymonitoredat381HuntingtonRoad,whichisneartheendofadead-endpipeinthesoutheasternpartofthedistributionsystem.The2018distributionsystemchlorineresidualsat381HuntingtonRoadareplottedinFigure7.

Figure7.DistributionSystemChlorineResidual

Page 9: Chester data evaluation report FINAL 6-27-19€¦ · FINAL REPORT Evaluation of Water Quality Data Chester Water Department, Chester MA Prepared by: Richard W. Gullick, PhD RCAP Solutions,

Page 9 of 22

Basedonthosedata,thefollowingobservationsweremade:

• ThechlorineresidualsmonitoredmonthlyattheWheelerOillocationhavebeenlowbutdetectable,averaging0.06mg/LfromJanuary2018throughApril2019,withaminimumof0.04mg/Landamaximumof0.11mg/L(Figure7).

• Therequiredminimumrequiredchlorineresidualofa“detectable”concentrationwasmetduringallRTCRsamplingeventsin2018.

• ItwouldbehelpfultomaintainahigherchlorineresidualattheendsofthedistributionsystemsuchastheWheelerOillocation.

• Biologicalgrowthindistributionsystemscanconsumechlorine.Onemeansforperiodicallyrestoringchlorineresidualsistoconductahigh-velocityflushingprogramonceortwiceayeartohelpcleanthepipes.ThatisrecommendedforChestertohelpmaintainthechlorineresiduals.

Tofurtherinvestigatedistributionsystemchlorineresiduals,RCAPSolutionsstaffconductedachlorinemappingexerciseofthedistributionsystemonMarch27,2019.Locationswereselectedbothnearthebeginningofthedistributionsystem,inthemiddle,andparticularlyneartheedges.ResultsarepresentedinFigure8andTable1.

Figure8.DistributionSystemChlorineMappingResults(3/27/19)

Page 10: Chester data evaluation report FINAL 6-27-19€¦ · FINAL REPORT Evaluation of Water Quality Data Chester Water Department, Chester MA Prepared by: Richard W. Gullick, PhD RCAP Solutions,

Page 10 of 22

Table1.DistributionSystemChlorineMappingResults(3/27/19)

~timefreechlorine

(mg/L)~flushrate

(gpm)~flushtime

(min)~flushed

volume(gal)Location

12:15 0.48 NM NM NMPOE-lowerbuldingatWTP(formerlowerchlorinatorbuilding)

12:35 0.37 NM NM NM WTPclearwelleffluent

14:02 0.39 2 3 6 191Rte.20(ChesterVillageMarket)

14:20 0.00 7.5 12 90 381Rte.20(WheelerOil)

14:40 0.01 4.3 16 69 309Rte.20(PostOffice)

15:20 0.15 NM 4 8 260Rte.20(Richie'sGeneralService)

15:50 0.25 NM 4 8 29MainSt.(ClassicPizza/BluenoteCafé)

16:45 0.25 NM 2 4 15MiddlefieldRoad(TownHall)

17:00 0.00 5 6 30 106MiddlefieldRoad(residence)

17:40 0.17 1.4 5 7 289Rte.20(DavidShepherdresidence)NM=notmeasured

Thefollowingobservationsweremadefromthechlorinemappingstudyresults:

• Chlorineresiduallevelsinandnearthecenteroftownweresatisfactory,rangingfromahighof0.39mg/LattheChesterVillageMarketlocationtoalowof0.15mg/LatRichie’sGeneralServiceat260Rte.20.

• NochlorineresidualwasdetectedneartheendsofthedistributionsystemonbothRte.20(0.01mg/LatthePostOffice,and0.00mg/LatWheelerOilCo.)andMiddlefieldRoad(0.00mg/Lat106MiddlefieldRd.).

• TherewasasuddenchangeinthechlorineresiduallevelinaveryshortdistanceonRte.20.Specifically,aresidenceat289Rte.20had0.17mg/Lchlorine,whilethePostOfficeafewbuildingsfurtheroutonRte.20hadonly0.01mg/L.ThereasonforthatisthePostOfficeisonadead-endpartofthepiping.Afterpassing289Rte.20,thepipingsplitswithadeadendgoingtothePostOffice,andthemainpipingleavingRte.20andfollowingBayStateDrivebacktoRte.20neartheWheelerOilCo.monitoringlocationat381Rte.20andthenashortwaystotheendofthedistributionsystem.

RCAPSolutionsalsousedthedistributionsystemmaptodevelopaninventoryofthepipinginthesystem.Determiningthetotalvolumeinthedistributionsystemcomparedtothechlorinecontacttimeinthetreatmentplantcanhelpdetermineifbleedingwateroutofthedistributionsystem(e.g.,viablow-offvalvesorableederassembly)cansignificantlyhelpreduceoverallwaterageandthusshortenchlorinecontacttime.Atpresent,thechlorinecontacttank(clearwell)volumeaverages~98,000gallons,andsecondprimarydisinfectionsegmentofthe8-inchpipe(betweenthetreatmentplantandtheoldchlorinatorbuilding)is~4,363gallons.Thecombinedtotalvolumeforchlorinecontacttimeduringprimarytreatmentis~102,000gallons.Thevolumeofwaterinthedistributionsystempipingwascalculatedtobeapproximately57,000gallons.Combiningthosetwovolumes

Page 11: Chester data evaluation report FINAL 6-27-19€¦ · FINAL REPORT Evaluation of Water Quality Data Chester Water Department, Chester MA Prepared by: Richard W. Gullick, PhD RCAP Solutions,

Page 11 of 22

resultsinatotalvolumeof~159,000gallons,ofwhich64%isprimarydisinfectionand34%isinthedistributionsystem.Withanaveragedemandof45,000gpd,thatcorrespondstowateragesof2.3daysforthetreatmentsystemand1.3daysforthedistributionsystem.Thismeansthatevenifthewholedistributionsystemwasflushedout,thewateragewouldstillbe~64%ofwhatithadbeen.Solargechangesinoverallwateragearenotexpectedtoresultfrombleedingwaterattheedgesofthesystem.Nonetheless,bleedingwateroutattheedgesofthedistributionsystemmaybeapossiblemeansofimprovingchlorineresidualatthoselocations.Thatoptionmaybeconsiderediftherecommendedunidirectionalflushingprogramisnotimplementedordoesnotprovidethenecessaryresults.Ifbleedingittobeconducted,itisusefultocalculatethevolumeofwaterthatisdesiredtobewasted.Onepossiblegoalwouldbetowaste(andthusmove)avolumeofwaterequivalenttothevolumeofwaterinthepipingbetweentheendofadead-endpipeandthelocationofthenearestacceptablechlorineconcentration.UsingthatapproachandthechlorineresidualdatafromtheMarch27,2019chlorinemappingstudy,thefollowingvolumeswouldneedtobewastedfromeachofthetwodeadends:

• Rte.20:~13,500gallonsfrom289Rte.20(0.17mg/Lchlorine)aroundBaystateDriveandtotheverysoutheastendofthesystemonRte.20pastWheelerOilCo.at381Rte.20

• MiddlefieldRoad:~8,700gallonsbetweentheTownHallat15MiddlefieldRoad(0.15mg/Lchlorine)outtotheendofthepipeatthenorthendofMiddlefieldRoad

Inthefield,flushingcouldcontinueuntilallcolorisgoneandanacceptablechlorineresidualisobtained(andassumingadequatepressureremainsthroughoutthedistributionsystem).8.pH:ThefinalcomponentofthetreatmentsystemispHadjustmentwithsodiumhydroxide.Unlessotherwisespecified,drinkingwatershouldhaveapHof6.5to8.5(pertheUSEPAsecondaryMCL).OptimalCorrosionControlTreatment(OCCT)ofteninvolvesanarrowertargetrangeforpH,andistypicallyabove7.0orhigher.ThefinishedwaterpHvaluesfor2018areshowninFigure9.ThefollowingobservationsweremaderegardingpH:

• ThepHdataarerelativelyscattered,coveringarangefrombelow7.0toabove8.5,withanarithmeticaverageof7.7.ItisbestfordistributionsystemwaterqualitytomaintainamoreconstantpH.ThesystemOperatorisawareofthisissue,andhastriedtomaintainasconstantapHaspractical.ChestercouldinvestigatehowtomaintainamoreconstantpH.

Page 12: Chester data evaluation report FINAL 6-27-19€¦ · FINAL REPORT Evaluation of Water Quality Data Chester Water Department, Chester MA Prepared by: Richard W. Gullick, PhD RCAP Solutions,

Page 12 of 22

Figure9.FinishedWaterpHin2018

• RCAPSolutionsdidnotfindaspecificMassDEPrequirementforthefinishedwaterpH.

However,thesystemOperatorexplainedthatDanLaPradeofMassDEPtoldhimtouseafinishedwaterpHrangeof7.3to7.5.ThatistoonarrowarangeofpHforpracticalimplementation,especiallyforalow-alkalinitywater,andshouldbewidened.AsisshowninFigure9,thatnarrowpHtargetwasnotmetveryfrequently.

• GiventhattheregulatorycomplianceissueiswithTHMsandnotleadandcopper,raisingthepHisnotrecommendedasthatcanresultinhigherTHMs(higherpHalsoresultsinaweakerchlorinedisinfectant).

• RCAPSolutionsrecommendsatargetfinishedwaterpHof7.5+/-0.3(i.e.,pHof7.2to7.8).Thiswouldwidentheallowablerangefromadifferenceof0.2uptoadifferenceof0.6pHunits.

9.DisinfectionByproducts:Twoclassesofdisinfectionbyproducts(DBPs)areregulatedbytheDisinfectant/DisinfectionByproductRule(D/DBPR):totaltrihalomethanes(TTHM,thetotalofthefourTHMs)andthetotaloffivehaloaceticacids(HAA5).ComplianceisdeterminedbymonitoringforTHMsandHAAsatselectdistributionsystemlocationsonceperquarter,andthencalculatingtheLocationalRunningAnnualAverage(LRAA)foreachsamplesite.TheTTHMandHAA5LRAAconcentrationsateachsamplesitemustnotbeabovetheMCLsof80µg/Land60µg/L,respectively.ThecurrentDBPmonitoringlocationsareat191HuntingtonRoad(ChesterVillageMarket),whichislocatednotfarfromthewatertreatmentplant,and381HuntingtonRoad(WheelerOilCo.),whichislocatedonadead-endlinenearthesoutheastendofthedistributionsystem.

Page 13: Chester data evaluation report FINAL 6-27-19€¦ · FINAL REPORT Evaluation of Water Quality Data Chester Water Department, Chester MA Prepared by: Richard W. Gullick, PhD RCAP Solutions,

Page 13 of 22

TheLocationalRunningAnnualAverageresultsforTTHMsarepresentedinFigure10,andforHAA5inFigure11.TheindividualTTHMresultsareplottedinFigure12forthesamplesiteatWheelerOilCo.,andfortheChesterVillageMarketinFigure13.IndividualHAA5resultsareshowninFigures14and15,respectively,forWheelerOilandChesterVillageMarket.ThesedatacoverthefullperiodthattheStage2D/DBPRhasbeenineffect,sincethebeginningof2013,andupthroughthe2ndquarterof2019.ThefollowingobservationsweremaderegardingTTHMandHAA5atthetwomonitoringlocations:

• TTHMshavebeenhighestattheWheelerOilCo.location,andHAA5havebeenhighestattheChesterVillageMarket.

• Intermsofregulatorycompliance,theMCLforTTHMswasexceededattheWheelerOilCompanylocation(381HuntingtonRoad)forthreequartersinarow(thethirdandfourthquartersof2018andthefirstquarterof2019).Themostrecentquarter’sresultsareincompliancewiththeDBPlimits,asthemaximumLRAAforTTHMis79µg/L.

• WhiletherehavebeennoexceedancesoftheMCLforHAA5,theLRAAhasattimescomeclosetotheMCL(Figure11andFigure15).ThehighestLRAAforHAA5was58µg/LattheChesterVillageMarketlocation(191HuntingtonRoad)on2/20/18,closetotheMCLof60µg/L.Assuch,HAA5arealsoofconcerninadditiontoTTHMs.

• ThereappearstobeasteadyincreaseinTTHMattheWheelerOilCo.location(381HuntingtonRoad)startingin4thquarterof2016.ThathasresultedinasteadyincreaseintheLRAAforTTHMsatthatsite,increasingfrom40µg/Lin3rdquarter2017upto92µg/Linthe4thquarterof2018.HAA5alsoincreasedduringasimilartimeperiod.Thecauseoftheseincreaseshasnotbeenidentified.Itisnotedthattheflushingprogramendedsometimearoundtwoyearsago.ItisalsopossiblethatthischangewasattributableatleastinparttoswitchingsourcewaterfromAustinBrookReservoirtoHornPond,butthetimingofthatswitchcouldnotbedeterminedandthusnocorrelationcouldbemade.

• ThetrendofincreasingTTHMconcentrationovertimeduringthepasttwoyearscontrastswiththetypicalTTHMseasonalpatternwherethehighestresultsarefoundinAugustduetothewarmertemperatures,andthelowestresultsinFebruaryduetocoldertemperatures.However,fortheChesterVillageMarketlocation,thehighestTTHMvaluesince2013was100µg/LinFebruary2018(HAA5alsowasatitshighestforthatlocationinFebruary2018),andthesecond-highestvalueof87µg/LwasinNovember2018.Incontrast,theAugust2018samplewasonly38µg/L.Noexplanationwasfoundforthisanomaly.

• TheLRAAdataforTTHMsshowninFigure10suggestthattherehavebeenperiodswheretheTTHMslevelswerenotmuchdifferentbetweenthetwosamplinglocations,including2013throughearly2015,and2017throughearly2018.Givenbothsamplesitesreceivewaterfromthesamesource,theonlyfactorthatwouldbeexpectedtoimpactdifferencesintheirTTHMlevelswouldbewatertraveltime(i.e.,chlorinecontacttime).Thereappearstobeaperiodfromlate2015through2016whenthewateragedifferencemayhavebeengreater,asthereisalargerdifferencebetweenthetwosamplesitesfortheTTHMLRAAs.

Page 14: Chester data evaluation report FINAL 6-27-19€¦ · FINAL REPORT Evaluation of Water Quality Data Chester Water Department, Chester MA Prepared by: Richard W. Gullick, PhD RCAP Solutions,

Page 14 of 22

Figure10.TTHMLocationalRunningAnnualAverages

Figure11.HAA5LocationalRunningAnnualAverages

Page 15: Chester data evaluation report FINAL 6-27-19€¦ · FINAL REPORT Evaluation of Water Quality Data Chester Water Department, Chester MA Prepared by: Richard W. Gullick, PhD RCAP Solutions,

Page 15 of 22

Figure12.TTHMat381HuntingtonRoad(WheelerOilCo.)

Figure13.TTHMat191HuntingtonRoad(ChesterVillageMarket)

Page 16: Chester data evaluation report FINAL 6-27-19€¦ · FINAL REPORT Evaluation of Water Quality Data Chester Water Department, Chester MA Prepared by: Richard W. Gullick, PhD RCAP Solutions,

Page 16 of 22

Figure14.HAA5at381HuntingtonRoad(WheelerOilCo.)

Figure15.HAA5at191HuntingtonRoad(ChesterVillageMarket)

Page 17: Chester data evaluation report FINAL 6-27-19€¦ · FINAL REPORT Evaluation of Water Quality Data Chester Water Department, Chester MA Prepared by: Richard W. Gullick, PhD RCAP Solutions,

Page 17 of 22

• InthecaseofHAAs,thereisacleardifferenceinHAA5levelsatthetwomonitoringsites,withlevelsattheWheelerOilCo.nearzero.ThisdifferenceinHAA5islikelyaresultofbiodegradationofHAA5withinthedistributionsystem,andgiventhelongerwaterageatWheelerOilCo.thereismoretimeforthebiodegradationtooccur.Whilethebiodegradationiscommoninthewarmermonths,itnormallyislessimpactfulduringthecoldermonths.Inthiscase,however,forthepastfouryearsbasicallyalloftheHAA5thathadbeenformedhaddegradedbythetimethewaterreachedtheWheelerOilCompanysite(Figure14).

• AnothernotabletrendisthatthreeofthefivehighestHAA5resultsoverthepastsixyearsfortheChesterVillageMarketwereinFebruary(Figure15).Typically,HAA5wouldbehigherinMayandNovemberthaninFebruary.ThismaysuggestsubstantialbiodegradationofHAA5leadingtotheChesterVillageMarketsite(despitethepresumedrelativelyshortwaterageatthatsite),astheFebruaryresultswereoftensubstantiallyhigherthanthedatafortheotherquarters,especiallythe3rdquartersamplinginAugust.

GiventherehavebeennoMCLexceedancesforHAA5,andthatthehighestTTHMexceedancewasbyonly15percentovertheMCL(asopposedtomuchhighervalues),averylargereductioninDBPsmaynotbenecessary.SimpleoperationalimprovementsmaybesufficienttoregainandmaintaincompliancewiththeDBPMCLs.Thoseimprovementsshouldbeimplementedandevaluatedpriortoconsideringanymajorcapitaladditiontothetreatmentsystem.ThreeapproachesarerecommendedatthistimeforimprovedcontrolofDBPs:

1. Implementaregularflushingprogram:Aswasdiscussedpreviously,semi-annualunidirectionalhigh-velocityflushingofthe

distributionsystemisrecommendedtohelpmaintainchlorineresidualsneartheendsofthesystem.FlushinghasalsobeenknowntobeabletoreduceDBPs,andthusisalsorecommendedforthatpurpose,especiallyforreductionofTHMs.Flushingcouldremovesomebiofilmfromtheinteriorofthepipes,whichcouldpotentiallyreducethebiodegradationofHAAs,andthusresultinhigherlevelsofHAAs.ThatpotentialeffectshouldbelookedforwhenreceivingthequarterlymonitoringresultsforDBPs.

2. Potentiallyswitchsourcewatertoreduceinfluentnaturalorganicmatter(NOM):Twosourcewatersareavailabletofeedthetreatmentplant.Itisrecommendedthat

Chesterregularlymonitorbothsourcewatersfortotalorganiccarbon(TOC).TOCservesasasurrogateforNOM.UV-254anddissolvedorganiccarbon(DOC)arealsoavailablesurrogatesforNOM.MonthlymonitoringofTOCisrecommendedforthefirstyear,butatminimumChestershouldsamplebothsourcewatersforTOConceperquarteronthesamedaysthatsamplingforDBPsisconducted.Turbidityshouldalsobemonitored,asthedecisionofwhichsourcetousemaybepredicatedontherelativelevelsofbothturbidityandTOC.TheTOCdatamaybeusedtodeterminewhichsourcewatertouse,especiallyduringthewarmermonthswhenTTHMformationismoreofaproblem.ItisexpectedthattheTOCinAustinBrookReservoirwillbelowerthanthatintheshallowerandslower-flowingHornPond.Therawwatertapinthetreatmentplantmaybeusedforsamplingthecurrentsourcewater,whileasampleoftheothersourcewatercanbecollectednearwherethewaterexitsthepond/reservoir.

Page 18: Chester data evaluation report FINAL 6-27-19€¦ · FINAL REPORT Evaluation of Water Quality Data Chester Water Department, Chester MA Prepared by: Richard W. Gullick, PhD RCAP Solutions,

Page 18 of 22

ThesourcewaterwasmonitoredforTOCfour(4)timesTOCin2018,withvaluesrangingfrom4.3to5.0mg/L.WhilethosesampleswerelabeledasbeingfromAustinBrookReservoir,theywerereportedlyfromHornPondasthatwasthesourcewaterbeingusedatthetime.Assuch,cautionshouldbeexercisedinusinganyrecentdatabecauseoftheissuewithsomeHornPondsamplesbeinglabelledasAustinBrookReservoir.

3. Optimizeuseofthegranularactivatedcarbon(GAC)sandwichfilterforremovalofNOMthroughimprovedmonitoringofTOC:

Filter#3hasthegranularactivatedcarbon(GAC)sandwich,withalayerofGACbetweentwolayersofsand.TheGACwasaddedtothisfilterforremovalofnaturalorganicmatter(NOM),whichisaprecursortoDBPformation.ThesorptivecapacityoftheGACforNOMandotherorganicchemicalsislimited.Theextentthesorptivecapacityhasbeenexhaustedcan,inpart,bemonitoredbyperiodicallyanalyzingtotalorganiccarbon(TOC)intheinfluentandeffluentfromthisfilter.WhentheeffluentTOCapproachestheleveloftheinfluentTOC,theactivatedcarbonisnearingexhaustionforadsorbingNOM.ConsiderationshouldbegiventoreplacingtheactivatedcarbonpriortoexhaustingitscapacitytoremoveNOM.

ATOCmonitoringprogramisrecommendedtohelpoptimizeuseoftheGACsandwichinFilter#3.MonthlymonitoringofTOCisrecommendedforthefirstyear,butatminimumChestershouldsamplefilterinfluentandfiltereffluentforTOConceperquarteronthesamedaysthatsamplingforDBPsisconducted.SampleandanalyzeforTOCinthefilterinfluent,theFilter#3effluent,andeithertheFilter#1orFilter#2effluentasacontrolsample.OnlyfilterscurrentlyonlineshouldbemonitoredforTOC.Sincethefilterinfluentsampleiseffectivelythesameasthesourcewatersampleforthecurrentsourcebeingused,itwouldbeprudenttodothissamplingonthesamedaysthattherawwaterTOCissampled,asrecommendedabove.

TOCwasmonitoredforboththerawwaterandfinishedwateron9/17/18and11/26/18,withTOCremovalbeing33%and13%,respectively(averagesof4.7mg/Linfluentand3.6mg/Leffluent).ItishopedthatamorestrategicandtargeteduseofthecarbonsandwichfilterwillresultinimprovedTOCremoval.

IfthoseapproachesdonotsatisfactorilyreduceDBPs,thenotherapproacheswouldneedtobeconsidered,includingpossiblybleedingwateroutoftheendsofthesystemtoreducewaterage,installingadditionaltreatmentcapabilitytoreduceNOM,orreducingpHtodecreaseTHMformation.10.Color:Nohistoricalcolordatawerefoundduringthisinvestigation.MassDEPmentionedcolorissuesintheirAugust24,2018lettertoChester,andalsomentionedinaninternalMassDEPe-maildatedAugust16,2018thatanearlierbrownwatercomplainthadbeenresolvedupondiscoveryandrepairofaleak.ThewatersystemOperatorhasreceivedafewcomplaintsaboutthewater’sappearance,includingayellowishcolor,andalightbrownishtea-likecolor.RCAPSolutionsstaffspokewithsometownresidentsabouttheirperceptionofthewaterqualityduringasitevisitonMarch27,2019,andsomeoftheresidentsnotedthatthewaterissometimescoloredeitherlightyelloworlightbrown.RCAPstaffconductedavisualexaminationofthewatercolorfromeachlocationthatchlorineresidualwasmeasuredduringthechlorinemappingstudyconductedonMarch27,2019.ThissimpletestinvolveslookingforcolorinawatersampleinsideawhiteStyrofoamcup.Distilledwaterwasusedfor

Page 19: Chester data evaluation report FINAL 6-27-19€¦ · FINAL REPORT Evaluation of Water Quality Data Chester Water Department, Chester MA Prepared by: Richard W. Gullick, PhD RCAP Solutions,

Page 19 of 22

comparisonasneeded.Ayellowtingetothewaterwasevidentatsomeofthelocations(butnotatalllocations),anditwasalighteryellowatsomelocationsthanatothers.AnexampleoftheyellowtintisshowninFigure16,whichcomparesadistributionsystemsamplewithdistilledwater.Nocolorwasdetectedinthetreatmentplant’sfinishedwater.

Figure16.Yellow-tingedWater(3/27/19)–

Distributionsystemsampleisontheleft,distilledwaterontherightOnecommoncauseofcolorationofdistributionsystemwateristhereleaseofiron,manganese,and/orothermetalsfromtheinteriorsurfaceofthepipe.Someofthepipesaremadeofiron,whilemanganesecandepositovertimeandbeasourceofcolorifitdissolvesintothewater.Manganesecancausewatertobeyellow,brown,orevenblack,dependingontheconcentration.Irontypicallyresultsinarust-coloredwater.Onemeansforreducingthesecolorissuesistomaintainasoundflushingprogramthathelpscleandepositsoffoftheinsideofthepipes.Chesterhashistoricallyconductedadistributionsystemflushingprogramtwiceperyear,butreportedlydidnotdothatthepasttwoyears.Resumingthesemi-annualflushingprogramisrecommendedtohelpreducethecolorobservedinthewater.Theflushingprogramshouldbeconductedunidirectionally,andwithsufficientvelocitytosufficientlycleantheinteriorofthepipes.Asnotedearlier,aproperlyconductedflushingprogramcanalsohelpmaintainchlorineresidualsandreducedisinfectionbyproducts.11.LeadandCopper:TheChesterWaterDepartmentprovidespHadjustmentasacorrosioncontrolmeasure.ThefinishedwaterpHisplottedinFigure9,andwasdiscussedpreviously.TheLeadandCopperRule(LCR)distributionsystemleadmonitoringdataarepresentedinFigure17andforcopperinFigure18.Basedontheavailabledata,leadandcoppercorrosiondoesnotappeartobeanissue,asneitherActionLevelhasbeenexceeded,andallindividualsampleresultswerebelowtheActionLevels.Thoughnotoptimal,thefluctuatingpHandchlorinelevelsdonotappeartohavecausedanyLCRcomplianceissues.

Page 20: Chester data evaluation report FINAL 6-27-19€¦ · FINAL REPORT Evaluation of Water Quality Data Chester Water Department, Chester MA Prepared by: Richard W. Gullick, PhD RCAP Solutions,

Page 20 of 22

Figure17.LCRLeadMonitoringResults(2013-2017)

Figure18.LCRCopperMonitoringResults(2013-2017)

12.SummaryandConclusions:Muchofthewaterqualityisgood,butimprovementcouldbemadeinreducingTHMs,HAAs,andcolor,andalsoforincreasingchlorineresidualsattheendsofthedistributionsystem.Implementationofasemi-annualhigh-velocityunidirectionalhigh-velocityflushingprogramisrecommended,andcouldhelpachieveallfourofthosegoals.ImplementationofamonitoringprogramforTOCisalsorecommendedtohelpselectwhichsourcewatertousetominimizeinfluentNOM,andtooptimizeuseoftheactivatedcarbonsandwichfilterforremovalofNOM.

Page 21: Chester data evaluation report FINAL 6-27-19€¦ · FINAL REPORT Evaluation of Water Quality Data Chester Water Department, Chester MA Prepared by: Richard W. Gullick, PhD RCAP Solutions,

Page 21 of 22

Basedontheavailabledata,leadandcoppercorrosiondoesnotappeartobeanissue,asneitherActionLevelhasbeenexceeded,andallindividualsampleresultswerebelowtheActionLevels.Thoughnotoptimal,thefluctuatingnatureofthepHandchlorinelevelsdonotappeartohavecausedanyLCRcomplianceissues.

13.Recommendations:ThefollowinglistsummarizestheprimaryrecommendationsdevelopedduringthisevaluationtohelptheChesterWaterDepartmentimproveoperationsandwaterquality:

DBPcontrol:

1. Implementasemi-annual,unidirectional,high-velocityflushingprogramtohelpcleanthedistributionsystempipes.ThiscanhelptoreduceDBPs,maintaindistributionsystemchlorineresiduals,andreduceincidentsofcoloredwater.Thosethreeissuesshouldbemonitoredcloselyafterflushinghasbeenconducted.Formaintainingchlorineresidual,focusonthenorthendofMiddlefieldRoadandthesoutheastendofRte.20.

2. ImplementaTOCmonitoringprogramforthetwosourcewaters(monitorturbidityalso).ConsiderusingthesourcewaterwiththelowerTOCduringthewarmerseasonstoreducetheamountofinfluentNOM,aslongasturbidityisnotanissue.DetailedsamplingrecommendationsareprovidedaboveinSection9.

3. ImplementaTOCmonitoringprogramforthefiltereffluenttohelpdeterminethesaturationstatusofthegranularactivatedcarboninFilter#3.UsethesedatatooptimizetimingoftheuseofFilter#3forremovalofNOM.DetailedsamplingrecommendationsareprovidedaboveinSection9.

Additionalprimaryrecommendationsincludethefollowing:

4. IftheunidirectionalflushingdoesnotsolvetheDBPandchlorineresidualissues,thenwateragecouldbecontrolledsomeattheedgesofthedistributionsystembywastingwaterthroughblow-offassemblies(i.e.,bleedingwateroutofthedistributionsystem).ThiscouldbedoneatthenorthendofMiddlefieldRoadandattheeastendofRte.20.

5. ProperlylabelthesourcewatersamplesasHornPondorAustinBrookReservoir(theyhavebeenmislabeledrecentlyasAustinBrookReservoirwhenitreallywasHornPondthatwassampled).

6. Installsampletapsforallthreeindividualfiltereffluents(IFEs)andalsofortheonecombinedfiltereffluent(CFE).ThereshouldbeanonlineturbiditymeterfortheCFEsampletouseforregulatorycompliancereporting.

Page 22: Chester data evaluation report FINAL 6-27-19€¦ · FINAL REPORT Evaluation of Water Quality Data Chester Water Department, Chester MA Prepared by: Richard W. Gullick, PhD RCAP Solutions,

Page 22 of 22

7. TurbidityresultsreportedtoMassDEPhavebeenforthefinishedwater(i.e.,treatmentplanteffluentatthePOE),butinsteadshouldbeforthecombinedfiltereffluent(CFE).Reportingcombinedfiltereffluentshouldlowertheresultsreportedfromanaverageof~0.11NTUtoapproximately~0.03NTU.

8. ImplementanewtargetfinishedwaterpHrangeof7.5+/-0.3(i.e.,7.2to7.8).

9. InvestigatehowtomaintainamoreconsistentfinishedwaterpH.

10. Investigatehowtomaintainamoreconsistentfinishedwaterchlorineresidual.

Otherrecommendationsincludethefollowing:

11. RCAPwasnotabletoobtainthespecificationsusedintheSCADAcalculationstodeterminethevolumeofthechlorinecontactors(partofdeterminingchlorinecontacttime),andthuscouldnotconfirmthisaccuracy.Also,thetracerstudythatresultedindeterminingabafflingfactorof0.13alsowasnotlocated.Thisinformationshouldbeobtainedandreviewedforaccuracy.Thatwouldhelpconfirmchlorineisnotbeingunderdosedoroverdosedasaresultofusinganinaccuratechlorinecontacttime,andconfirmthatbothdisinfectionsegmentsarenecessary.

12. TheSCADAsystemcouldbeimprovedtoincludetrendchartsofallwaterqualitydata.

13. TheTownofChestershouldbecomemoreinvolvedinthewatersystemoperations,especiallythetreatmentsystem,toreducerelianceonthecontractedcertifiedoperator,andtogainabetterunderstandingoftheissuesfacingthewatersystem,aswellasthetimeandresourcecommitmentsthatareneededtoensureefficientandsustainableoperationsandfuturecompliancewithallapplicableregulations.

14. Improvedatamanagement,includingtabulatingandplottingallhistoricaldata.SomeoneattheTownshouldfollowthedataandcomplianceissues,notjustthecertifiedoperator.

15. Developandmaintainacustomercommentlog.

16. Developandimplementapublicrelationscampaignaboutwaterquality.

17. Formonitoringsites,includetheaddressinthesitename(e.g.,“381Rte.20”or“WheelerOilCo./381Rte.20”).

18. UpdatethenameoftheWalkerBrookStoresamplesitetothecurrentnameofChesterVillageMarket(at191Rte.20/HuntingtonRd.).