35
Chicago PET Development and Recent Progress in Digital TOFPET 1. Heejong Kim, Chien-Min Kao, Qingguo Xie, Yun Dong, Ming-Chi Shih, Antonio Machado, and Chin-Tu Chen 2. Octavia Biris, Jialin Lin, Fukun Tang, Lin Zhou, and Henry Frisch 3. Robert Wagner, Karen Byrum, and Gary Drake 4. Woon-Seng Choong and William Moses 1. Department of Radiology & Committee on Medical Physics, University of Chicago, IL 2. Enrico Fermi Institute & Department of Physics, University of Chicago, IL 3. High Energy Physics Division, Argonne National Laboratory, Argonne, IL 4. Lawrence Berkeley National Laboratory, Berkeley, CA

Chicago PET Development and Recent Progress in Digital TOFPET

  • Upload
    lani

  • View
    22

  • Download
    0

Embed Size (px)

DESCRIPTION

Chicago PET Development and Recent Progress in Digital TOFPET. 1. Heejong Kim, Chien-Min Kao, Qingguo Xie, Yun Dong, Ming-Chi Shih, Antonio Machado, and Chin-Tu Chen 2. Octavia Biris, Jialin Lin , Fukun Tang, Lin Zhou, and Henry Frisch - PowerPoint PPT Presentation

Citation preview

Page 1: Chicago PET Development and  Recent Progress in Digital TOFPET

Chicago PET Development and Recent Progress in Digital TOFPET

1. Heejong Kim, Chien-Min Kao, Qingguo Xie, Yun Dong, Ming-Chi Shih, Antonio Machado, and Chin-Tu Chen

2. Octavia Biris, Jialin Lin, Fukun Tang, Lin Zhou, and Henry Frisch

3. Robert Wagner, Karen Byrum, and Gary Drake4. Woon-Seng Choong and William Moses

• 1. Department of Radiology & Committee on Medical Physics, University of Chicago, IL

• 2. Enrico Fermi Institute & Department of Physics, University of Chicago, IL

• 3. High Energy Physics Division, Argonne National Laboratory, Argonne, IL

• 4. Lawrence Berkeley National Laboratory, Berkeley, CA

Page 2: Chicago PET Development and  Recent Progress in Digital TOFPET

PET Imaging Chain and UC PET R&DCyclotron/

Radiotracer [Multi-Modality

Probes]

Subject (Human/Animal)

Quantitative Image Analysis

[MM QIA & List-Mode Dynamic 4D/5D QIA]

Detector & System

[Panel-PET & SiPM]

Image Reconstruction

[MM-IR & ROI-IR]

Performance Evaluation

[Task-Based Assessment]

Electronics [Digital PET]

Integration with Medicine & Biology

Clinical Outcomes& BiologicalDiscoveries

[Cancer, Cardiac, Brain, Drug, etc.]

Page 3: Chicago PET Development and  Recent Progress in Digital TOFPET

Quantitative ImagingMulti-Modality Integration

High-PerformanceLow-Cost

Broad-Access

Page 4: Chicago PET Development and  Recent Progress in Digital TOFPET

PET Imaging Chain and UC PET R&DCyclotron/

Radiotracer [Multi-Modality

Probes]

Subject (Human/Animal)

Quantitative Image Analysis

[MM QIA & List-Mode Dynamic 4D/5D QIA]

Detector & System

[Panel-PET & SiPM]

Image Reconstruction

[MM-IR & ROI-IR]

Performance Evaluation

[Task-Based Assessment]

Electronics [Digital PET]

Integration with Medicine & Biology

Clinical Outcomes& BiologicalDiscoveries

[Cancer, Cardiac, Brain, Drug, etc.]

Page 5: Chicago PET Development and  Recent Progress in Digital TOFPET

Patient 1 Patient 2

MR PET MR PET

Imaging of Life andLife Processes

Live Brain Dead Brain

Page 6: Chicago PET Development and  Recent Progress in Digital TOFPET

Task-Based Image Quality AssessmentTasks – Detection and Estimation

Page 7: Chicago PET Development and  Recent Progress in Digital TOFPET

2008 IEEE NSS/MIC/RTSDMIC Short Course

" Image Quality in Adaptive and Multimodality Imaging"

20 October 2008Dresden, Germany

Organizer: Harrison Barrett, Matthew A. Kupinski,

Lars R. Furenlid

Page 8: Chicago PET Development and  Recent Progress in Digital TOFPET

PET Imaging Chain and UC PET R&DCyclotron/

Radiotracer [Multi-Modality

Probes]

Subject (Human/Animal)

Quantitative Image Analysis

[MM QIA & List-Mode Dynamic 4D/5D QIA]

Detector & System

[Panel-PET & SiPM]

Image Reconstruction

[MM-IR & ROI-IR]

Performance Evaluation

[Task-Based Assessment]

Electronics [Digital PET]

Integration with Medicine & Biology

Clinical Outcomes& BiologicalDiscoveries

[Cancer, Cardiac, Brain, Drug, etc.]

Page 9: Chicago PET Development and  Recent Progress in Digital TOFPET

ABT

Biomarker

Generator

Micro AcceleratorMicro Accelerator

Microchemistry & Microfluidics

Key Characteristics of Key Characteristics of

Biomarker GeneratorBiomarker Generator

• Lower cost & much smaller to be Lower cost & much smaller to be located at scannerlocated at scanner

• To be an approved FDA medical To be an approved FDA medical devicedevice

• Produce dose of F-18 or C-11 Produce dose of F-18 or C-11 biomarker in 20 minutesbiomarker in 20 minutes

• Base chemistry system for drug Base chemistry system for drug discoverydiscovery

• Handling of micro to millicuries, not Handling of micro to millicuries, not curiescuries

Courtesy ofNanotek & ABT

Page 10: Chicago PET Development and  Recent Progress in Digital TOFPET

Multi-Modality Targeting Molecular Imaging & Therapeutic Probes

(Phage and Micelle Nanosystem)

Ultrasound, MRI, SPECT, PET, X-Ray/CT, Fluorescence & Therapeutics

Page 11: Chicago PET Development and  Recent Progress in Digital TOFPET

PET Imaging Chain and UC PET R&DCyclotron/

Radiotracer [Multi-Modality

Probes]

Subject (Human/Animal)

Quantitative Image Analysis

[MM QIA & List-Mode Dynamic 4D/5D QIA]

Detector & System

[Panel-PET & SiPM]

Image Reconstruction

[MM-IR & ROI-IR]

Performance Evaluation

[Task-Based Assessment]

Electronics [Digital PET]

Integration with Medicine & Biology

Clinical Outcomes& BiologicalDiscoveries

[Cancer, Cardiac, Brain, Drug, etc.]

Page 12: Chicago PET Development and  Recent Progress in Digital TOFPET

Image Co-Registration & Integration

Fusion of PET, SPECT, MRI, CT,

EPRI, Histology

Halpern, Pelizzari KarczmarWeichselbaum

Page 13: Chicago PET Development and  Recent Progress in Digital TOFPET

PET Imaging Chain and UC PET R&DCyclotron/

Radiotracer [Multi-Modality

Probes]

Subject (Human/Animal)

Quantitative Image Analysis

[MM QIA & List-Mode Dynamic 4D/5D QIA]

Detector & System

[Panel-PET & SiPM]

Image Reconstruction

[MM-IR & ROI-IR]

Performance Evaluation

[Task-Based Assessment]

Electronics [Digital PET]

Integration with Medicine & Biology

Clinical Outcomes& BiologicalDiscoveries

[Cancer, Cardiac, Brain, Drug, etc.]

Page 14: Chicago PET Development and  Recent Progress in Digital TOFPET

600 ps

2 ns

Page 15: Chicago PET Development and  Recent Progress in Digital TOFPET

PET Imaging Chain and UC PET R&DCyclotron/

Radiotracer [Multi-Modality

Probes]

Subject (Human/Animal)

Quantitative Image Analysis

[MM QIA & List-Mode Dynamic 4D/5D QIA]

Detector & System

[Panel-PET & SiPM]

Image Reconstruction

[MM-IR & ROI-IR]

Performance Evaluation

[Task-Based Assessment]

Electronics [Digital PET]

Integration with Medicine & Biology

Clinical Outcomes& BiologicalDiscoveries

[Cancer, Cardiac, Brain, Drug, etc.]

Page 16: Chicago PET Development and  Recent Progress in Digital TOFPET

Silicon PM Characterization

Source: F-18

Front

Back

LYSO:1x1x10mm3, 2x2x10mm3

MPPC: 1x1mm2

25-m, 50-m, or 100-m

Page 17: Chicago PET Development and  Recent Progress in Digital TOFPET

F-18/LYSO Sample Pulses

PMT

50-m MPPC

25-m MPPC

100-m MPPC

Page 18: Chicago PET Development and  Recent Progress in Digital TOFPET

A Table-Top PrototypeThe prototype consists of two HRRT (High Resolution Research Tomograph) detector heads. The spacing between detectors shown is ~6 cm, which is adequate for imaging rodents.

A single double-layered, 8 x 8 LSO crystal block affixes onto 4 photomultiplier tubes in the quadrant-sharing configuration.

HRRT Detector Heads

CNMF, September 26, 2008

Page 19: Chicago PET Development and  Recent Progress in Digital TOFPET

Central Sensitivity(GATE Simulation, 20% ER, 3ns TR)

0

5

10

15

20

25

30

200 250 300 350 400 450

2ns

6ns

10ns

LLD (keV)

Sensitivity

(%)

Page 20: Chicago PET Development and  Recent Progress in Digital TOFPET

Noise-Equivalent Count RateComparison with reported NECR peaks

Reported NECR peaks

Reported NECR peaks

Mouse RatMouse

Page 21: Chicago PET Development and  Recent Progress in Digital TOFPET

FDG Resolution phantomreal data

2.4 mm

2.0 mm

1.0 mm

1.35mm

1.7 mm

0.75mm

Modeling the responses by MC simulation

Ideal line integral

Page 22: Chicago PET Development and  Recent Progress in Digital TOFPET

Sample Imagereal FDG-Rat data

Ideal line integral Modeling response

22

Page 23: Chicago PET Development and  Recent Progress in Digital TOFPET

Initial FDG-Rat Images

Coronal

Transaxial

Sagittal

Page 24: Chicago PET Development and  Recent Progress in Digital TOFPET

PET Imaging Chain and UC PET R&DCyclotron/

Radiotracer [Multi-Modality

Probes]

Subject (Human/Animal)

Quantitative Image Analysis

[MM QIA & List-Mode Dynamic 4D/5D QIA]

Detector & System

[Panel-PET & SiPM]

Image Reconstruction

[MM-IR & ROI-IR]

Performance Evaluation

[Task-Based Assessment]

Electronics [Digital PET]

Integration with Medicine & Biology

Clinical Outcomes& BiologicalDiscoveries

[Cancer, Cardiac, Brain, Drug, etc.]

Page 25: Chicago PET Development and  Recent Progress in Digital TOFPET

Digital PET Data AcquisitionA Multi-Threshold Approach

TDC

TDC

TDC

TDC

PMT IN

V4

V3

V2

V1

discriminators

Page 26: Chicago PET Development and  Recent Progress in Digital TOFPET

Multi-Threshold Approach

•Sampling pulse at pre-defined voltage levels.

•Output : only digitized timings.

•Pulse reconstruction using digitized timings. •Remove analog blocks. (Pre-Amp, ADC, CFD)

•Digital Signal Processing (DSP) technology can be utilized. (event time, energy)

PMT waveform by 20GS/s oscilloscopesuperimposed with timing readouts by the multi-threshold board + HPTDC

Page 27: Chicago PET Development and  Recent Progress in Digital TOFPET

Multi-Threshold Board + HPTDC

Multi-threshold discriminator board•2 boards with 4channels in each.

•0-700mV of adjustable threshold level. •Used ADCMP582 comparators.

•Timings at leading and falling edges.

Multi-threshold board (left)connected to HPTDC module (right).

Input

HPTDC (CERN)

4 chs output

Threshold SetHigh Performance TDC (HPTDC) 8/32 channels. 25 ps/bit. developed at CERN.

Page 28: Chicago PET Development and  Recent Progress in Digital TOFPET

Experimental Setup

•Two Hamamatsu R9800 photomultiplier tubes (HV = -1,300V)•Coupled with LSO crystals ( 6.25x6.25x25mm3).•Separated 5cm apart.•Na-22 used for positron source located at the center.•Multi-threshold discriminator board setup: Inputs from 2 PMT signals Thresholds : 50, 100, 200, 300mV•Timing Readout : TDS6154 oscilloscope20GS/s. (Tektronix) HPTDC. ( 8chs, 25 ps/bit, developed at CERN)

A Block diagram of the setup.

Page 29: Chicago PET Development and  Recent Progress in Digital TOFPET

•Sent pulse generator signals to two channels.

•Measured time difference with the TDS6154 oscilloscope.

•Time resolution of single channel : ~13.3ps(FWHM)

Time offset between two channelsof the Multi-threshold discriminator.

Time Resolution of Discriminator

Page 30: Chicago PET Development and  Recent Progress in Digital TOFPET

Pulse Reconstruction (HPTDC)

Energy distribution of 511keV gamma.

•Select the gamma coincidence events. events with 2, 3 and 4 hits from each board.

•Reconstructed pulse shape.

•Linear fit on the leading edge. (event time).

•Exponential fit on the falling edge. (energy, decay constant)

Page 31: Chicago PET Development and  Recent Progress in Digital TOFPET

Pulse Recontstruction - 2

The decay time constant.

20GS waveform

Multi-threshold

Energy resolution

13%(FWHM) 18%

Decay constant

45ns (4ns width)

44ns (9ns width)

Page 32: Chicago PET Development and  Recent Progress in Digital TOFPET

Coincidence Timing Resolution

Time difference of 511keV gammacoincidence events

•Select the coincidence events.

•Least square fit to the leading edge timings.

•Use two leading edges with100, 200mV thresholds.

•Extrapolated at 0mV.

•The time difference, t1-t2. (FWHM) Oscilloscope : 330ps HPTDC : 350ps

Page 33: Chicago PET Development and  Recent Progress in Digital TOFPET

PET Imaging Chain and UC PET R&DCyclotron/

Radiotracer [Multi-Modality

Probes]

Subject (Human/Animal)

Quantitative Image Analysis

[MM QIA & List-Mode Dynamic 4D/5D QIA]

Detector & System

[Panel-PET & SiPM]

Image Reconstruction

[MM-IR & ROI-IR]

Performance Evaluation

[Task-Based Assessment]

Electronics [Digital PET]

Integration with Medicine & Biology

Clinical Outcomes& BiologicalDiscoveries

[Cancer, Cardiac, Brain, Drug, etc.]

Page 34: Chicago PET Development and  Recent Progress in Digital TOFPET

Motor Activity Study (Stroke)

Page 35: Chicago PET Development and  Recent Progress in Digital TOFPET

Motor Activity Studies