9
Visit : www.theallpowersource.com E-mail : [email protected] CIRCUIT BREAKERS CIRCUIT BREAKERS

Circuit Breakers - The All Power Source

Embed Size (px)

DESCRIPTION

The AllPowerSource is the top choice for circuit breakers.

Citation preview

Visit : www.theallpowersource.comE-mail : [email protected] BREAKERSCIRCUIT BREAKERS100 100 100S h Sc ho Sc ho l S ol S ol Stt r ee t r eet B t B t , Ber ge er ge f l nfel nfel d N d N d, NJ 07 J 07 J 07621 621 621Phone:(201)385-0500Fax:(201)385-0702THEALLPOWERSOURCEFor more information, please visit us at www.theallpowersource.com or email us at [email protected] Allpower Source (TAS) is a division of Technology Dynamics Inc. (TDI) in Bergenfeld NJ, with 3 modern facilities totaling over 50,000 square feet and over 100 dedicated employees. Established in 1976, Technology Dynamics Inc. is a leading manufacturer of standard, modifed and fully custom Switching Power Supplies and DC-DC Converters for both commercial and military applications. The Allpower Source division specializes in engineering, manufacturing and distribution ofspecialized components for the power supply industry. Its product mix spans the range of electrical, electromechanical andmechanicalitemsspecifcallytargetedtothepowersupply,militaryandcommercialindustry. TAS ofers products and services at extremely competitive prices and quick delivery to power supply engineers often unable to get custom parts such as heatsinks or EMI flters at low prices, and quick turn around. TAS products are deployed in the most advanced military systems. TAS products are used in power systems which were fully qualifed to MIL-STD-461, MIL-STD-810 and MIL-STD-1399. TAS products are either imported from all over the world or manufactured in America. Custom parts are made with very low tooling cost and in just a few weeks. Non-custom parts are mostly from stock or 2 weeks delivery. Very broad line of products not readily available in the USA. We are here to serve the power supply exclusively.Facility of Electronic Integration Technologya subsidiary of Technology Dynamics Inc.ABOUT US Circuit ProtectorCBP3 PA - SeriesMINI PLUG TYPESuitableforsmallsized equipment and protector of power source circuit.CBP3 PS - SeriesMINI SIDE-SCREW TYPESuitableforsmallsized equipment and protector of power source circuit.CBP3 P - SeriesPLUG TYPESuitableforprotectorof powersourcewithplug type structure.CBP3 S - SeriesSIDE-SCREW TYPEApplicabletopressed screw terminal.CBP5 B - SeriesBOLT TERMINALMountabletobusbar, pressedterminaland other various circuits.III100 100 100S h Sc ho Sc ho l S ol S ol Stt r ee t r eet B t B t , Ber ge er ge f l nfel nfel d N d N d, NJ 07 J 07 J 07621 621 621Phone:(201)385-0500Fax:(201)385-0702THEALLPOWERSOURCEFor more information, please visit us at www.theallpowersource.com or email us at [email protected] CURVESCircuit Protector / CBP SeriesOperating TimeOperating TimeOperating TimeOperating TimeCurrent (% of Rated Current)Current (% of Rated Current) Current (% of Rated Current)Current (% of Rated Current)INSTANTANEOUS TYPE (I) HIGH (H)MEDIUM (M) LOW (L)TYPEOperation Time (seconds) according to Overload (%)100% 125% 130% 150% 200% 300% 400% 600% 800%INSTANT(I)NO TRIP 0.017 ~ 1.0 0.012 ~ 0.5 0.01 ~ 0.1 0.007 ~ 0.065 0.0065 ~ 0.05 0.006 ~ 0.032 0.005 ~ 0.027 0.003 ~ 0.025HIGH(H)NO TRIP 0.75 ~ 12 0.5 ~ 9 0.32 ~ 4.5 0.15 ~0.2 0.08 ~ 0.8 0.02 ~ 0.25 0.009 ~ 0.12 0.004 ~ 0.07MEDIUM(M)NO TRIP 15 ~ 120 9 ~ 90 4.5 ~ 60 2.5 ~ 20 0.6 ~ 8.0 0.3 ~ 2.5 0.035 ~ 0.75 0.007 ~ 0.15LOW(L)NO TRIP 70 ~ 900 60 ~ 750 40 ~ 260 15 ~ 70 5 ~ 60 0.05 ~ 15 0.02 ~ 4.0 0.01 ~ 0.25TRIPPING TIMELOAD APPLICATIONSBY PROTECTION CHARACTERISTICS TYPECHARACTERISTICS FEATURES OF APPLIED LOADS SUITABLE LOADSINSTANT (I) Equipment that takes very quick interruption due to its low overload resistance. Solid State Circuit, SCR, TRIAC, etc.HIGH (H) Equipment with low starting in-rush current that requires rapid interruption. Solid State Circuit, etc.MEDIUM (M) Equipment with in-rush current of 5 or 6 times that needs protection in a wide region. General Sequence Circuit, etc.LOW (L) Equipment whose starting inrush current is very high. Solenoid Valve Heater, Motor.Operating time depending on the Ambient TemperatureThe operating time is based on the reference temperature of250C.Theoperatingtimeatadiferentambient temperatureshouldbecompensatedforbyuseofthe followingcompensationcurve.Buttheinstantaneous type is not infuenced by the ambient temperature.Interrupting efciency depending on the Mounting AngleTheoperatingcurrentvariesinaccordancewiththe mounting angle. Use the circuit breaker after compensating the rated current for its mounting angle.Warning for use of circuit breaker for equipment1. The circuit breaker for equipment protection should be installed with the correct mounting angle such that pushing the handle upward turns on the breaker. It should be tightly fxed to the panel by screws.2. Thedepthofascrewtakenbythecircuitbreakerin5mm.Selectthelengthofthescrewswiththisdepthandthe thickness of the panel.3. Withregardtothecircuitbreakerwithalowratedcurrent,verifythespecifcationandimpedanceofthecoiland check the operating voltage.4. The instantaneous type should be used where there is not in-rush current. In case it is inevitable to use an instantaneous type in such a situation, use a circuit breaker whose rated current is more than twice of the normal operating current.5. When you solder a wire to the terminal, solder it within 5 seconds using a soldering iron of 40 W or smaller as far as auxiliary and alarm contacts are concerned.6.Foroperatingenvironment,selectalocationwithasmallamountofdustandverygoodventilation.Wireswith sufcient current capacity should be tightly connected to the terminal.IIIIVINTERNAL CIRCUITSORT TYPE INNER CIRCUIT CIRCUIT APPLICATION DESCRIPTIONINTERNAL CIRCUITSeries Trip(S)Asthemostgeneralapplication,thecircuit provides the on-of switch function as well as overcurrent and short circuit protection.Parallel Trip(P)Itopensandclosestwoloadsatthesame time.IfthereisadefectonloadA,the circuitbreakerinterruptsthetwoloads simultaneously.Switch Only(O)Ithasnoovercurrenttrippingfunctionbut the on-of switch capability only.Relay Trip(R)The main contact circuit and the over current detectioncircuitareinternallyseparated. Thecircuitbreakerdetectsovercurrentof load B and trips load A accordingly.ACCESSORYAuxiliary Switch(W)Theauxiliaryswitchisturnedonandof, linkedwiththemaincontactofthecircuit breaker and can be used to display the state of the breaker remote by a lamp or another device.Alarm Switch(A)Alarmswitchchangesthestateonlywhen themaincontactinterruptsovercurrent and resets when the handle is turned on. By meansofalamporbuzzer,thesignalcan beutilizedasthesourceofanovercurrent alarm.Voltage Trip(V)Thecontactcircuitandtheovercurrent detectioncircuitareinternallyseparated. Whentheratedvoltageisappliedtoload B,thebreakertripsthecircuitofloadA.In casevoltagetripof1pole,itdoesnothave interrupting function for overcurrent.100 100 100S h Sc ho Sc ho l S ol S ol Stt r ee t r eet B t B t , Ber ge er ge f l nfel nfel d N d N d, NJ 07 J 07 J 07621 621 621Phone:(201)385-0500Fax:(201)385-0702THEALLPOWERSOURCEFor more information, please visit us at www.theallpowersource.com or email us at [email protected] BY PROTECTION CHARACTERISTICSCLASSIFICATIONAPPLIED CIRCUITSWARNING FOR PRODUCT SELECTIONPERFORMANCE CHARACTERISTICS OF APPLIED PRODUCTSEXAMPLE EXAMPLE FEATURES OF CIRCUITS INSTANT HIGH MIDDLE LOWOverload resistance of theload is relativelylarge.In caseovercurrent is much higher than therated currentfows when you are usingin normal conditionsMotor CircuitStaring currentabout5 to7 times of the rated value. Starting timedependsonthe mechanicalinertia of the load.Burn-outmayoccurat120~130% ofthe rated value.Itisnecessarytounderstandtheoverloadresistanceoftheload(de-arcing characteristics), the ratio of the in-rush currentto the operating current and its lasting time.

Solenoid CircuitStarting current is much morethan 10 times of the rated value.Inasolenoid, inrushcurrentmay continue very long. Trans CircuitStarting excitation current muchmore than 10 times of the rated value. In caseovercurrent is not too much higherSequencecontrolcircuits by relay, etc.Primarily for protection from a large current like short circuit of relay winding or short circuit between the wires.

Overload Resistance of the load is small.SCR Triac and semi-conductorWith low overload resistance,the load will be damaged unless overcurrent is tripped in a short period of time. Since it is difcult to protect a semiconductor element from10 times of the average current,the circuit breakers are primarily for protection from overload. In combination with a semiconductorprotection fuse, the element can beprotected perfectly. Circuit Breaker /Applied CircuitRated VoltageFrequencyRated Current Number of Poles Operating CharacteristicsInterrupting CapacityMounting Method AccessoriesVoltage, Frequency Circuit Method Max. Load Current Type, Character of the loadObject of Protection Short Circuit Current Miscellaneous VVI100 100 100S h Sc ho Sc ho l S ol S ol Stt r ee t r eet B t B t , Ber ge er ge f l nfel nfel d N d N d, NJ 07 J 07 J 07621 621 621Phone:(201)385-0500Fax:(201)385-0702THEALLPOWERSOURCEFor more information, please visit us at www.theallpowersource.com or email us at [email protected] FRAME 30 30Model CBP31PA CBP32PA CBP33PA CBP31PS CBP32PS CBP33PSRatingPole 1 2 3 1 2 3Rated Current (In) (A) 0.1, 0.3, 0.5, 1, 2, 3, 5, 7, 10, 15, 20, 25, 30, (34)RatedVoltage (Ue)AC (V) 250 / 380DC (V) 65Operating Characteristics Instant(I), High(H), Middle(M), Low(L)Rated Ultimate Breaking Capacity(kA) sym KSC8321, IEC60934, UL1077AC 250 V 1 kADC 65 V 1.5kANumber of operating cycleWithout Current (times) 4000With Current (times) 6000Dimension [mm]a 0.65 [16.5] 1.28 [32.5] 1.93 [49] 0.65 [16.5] 1.28 [32.5] 1.93 [49]b 1.65 [42]c 1.65 [42]d 0.57 [14.5]Weight[kg] 0.15 lbs [0.07] 0.35 lbs [0.16] 0.57 [0.26] 0.15 lbs [0.07] 0.35 lbs [0.16] 0.57 [0.26]Automatic tripping device Hydraulic-Magnetic (HM)Connections Plug Type Side-Screw typeInternal CircuitSeries Trip(S) OParallel(P) --Switch Only (O) ORelay Trip(R) --AccessoriesAux. Switch(W) OAlarm Switch (A) OVoltage Trip (V) O (2P)Ambient Temperature -400 C ~ 850CAux. Contact Capacity 250 VAC 3AApproval Standard UL O IN PROGRESSCircuit ProtectorMini Plug TypeCBP3 PA - SeriesCBP3 PS - Series 1.26 [32]0.64[16.2]1.28 [32.4]0.64[16.2]1.28[32.4]1.91 [48.6]1.65 [42]1.65 [42]0.67 [17]OFF60 ON0.31 [8]M4*0.24[6]1.26 [32]0.64[16.2]1.28 [32.4]0.64[16.2] 0.64[16.2]0.64[16.2]1.28 [32.4]0.64[16.2]0.64[16.2] Dimension Inner Circuit1 Pole 2 Pole (H) 2 Pole (I) 3 Pole (H) 3 Pole (I)Side Type Screw Mounting Dimension1 Pole 2 Pole 1 Handle 2 Pole 3 Pole 1 Handle 3 PoleFeatures Various rated currents (0.1A ~ 45A) Indicate ON-OFF with Toggle Lever Various Optional Functions Adoption of ARC GRID with High Breaking Capacity Plug, Side Screw Terminal Type Available 1 handle of 2 poles and 1 handle of 3 PolesApplications Various power distribution boards Telecommunication equipment UPS, Rectifer Inverter Welding Machines Machine Tools (Press, Discharger etc.) Available 1 handle of 2 poles and 1 handle of 3 Poles12100 100 100S h Sc ho Sc ho l S ol S ol Stt r ee t r eet B t B t , Ber ge er ge f l nfel nfel d N d N d, NJ 07 J 07 J 07621 621 621Phone:(201)385-0500Fax:(201)385-0702THEALLPOWERSOURCEFor more information, please visit us at www.theallpowersource.com or email us at [email protected] FRAME 30 30Model CBP31P CBP32P CBP33P CBP31S CBP32S CBP33SRatingPole 1 2 3 1 2 3Rated Current (In) (A) 0.1, 0.3, 0.5, 1, 2, 3, 5, 7, 10, 15, 20, 25, 30, (34), (40), (45)RatedVoltage (Ue)AC (V) 250 / 380DC (V) 65Operating Characteristics Instant(I), High(H), Middle(M), Low(L)Rated Ultimate Breaking Capacity(kA) sym KSC8321, IEC60934, UL1077AC 250 V 1 kADC 65 V 1.5kANumber of operating cycleWithout Current (times) 4000With Current (times) 6000Dimension [mm]a 0.75 [19] 1.5 [38] 2.24 [57] 0.75 [19] 1.5 [38] 2.24 [57]b 2.1 [53]c 1.57 [40]d 0.67 [17]Weight (kg) 0.17 lbs [0.08] 0.4 lbs [0.18] 0.66 lbs [0.3] 0.17 lbs [0.08] 0.4 lbs [0.18] 0.66 lbs [0.3]Automatic tripping device Hydraulic-Magnetic (HM)Connections Plug Type Side-Screw typeInternal CircuitSeries Trip(S) OParallel(P) OSwitch Only (O) ORelay Trip(R) OAccessoriesAux. Switch(W) OAlarm Switch (A) OVoltage Trip (V) --Ambient Temperature -400 C ~ 850CAux. Contact Capacity 250 VAC 3AApproval Standard UL O ---Circuit ProtectorStandard Plug TypeCBP3 P - SeriesCBP3 S - Series0.37[9.5]1.55[39.3]0.66[16.8]2.00 [51]1.54 [39]0.22 [5.5]0.75[19]1.5[38]2.24[57]1.65 [42]0.37[9.5]1.55 [39.3]1.53 [39]0.23 [6]1.53 [39]1.55 [39.3]0.24[6.3]2 - 0.14[3.5]0.6 [15.5]1.04 [26.5]1.65[42]2 - 0.14[3.5] 2 - 0.14[3.5]1.5[38]0.75[19]0.75[19]0.63[16]1 Pole 2 Pole 3 PoleSide Screw Type Aux Switch (W) TypeFeatures Various rated currents (0.1A ~ 45A) Indicate ON-OFF with Toggle Lever Various Optional Functions Adoption of ARC GRID with High Breaking Capacity Plug, Side Screw Terminal TypeApplications Various power distribution boards Telecommunication equipment UPS, Rectifer Inverter Welding Machines Machine Tools (Press, Discharger etc.) Dimension Inner Circuit Mounting Dimension34100 100 100S h Sc ho Sc ho l S ol S ol Stt r ee t r eet B t B t , Ber ge er ge f l nfel nfel d N d N d, NJ 07 J 07 J 07621 621 621Phone:(201)385-0500Fax:(201)385-0702THEALLPOWERSOURCEFor more information, please visit us at www.theallpowersource.com or email us at [email protected] FRAME 50Model CBP51B CBP52B CBP53BRatingPole 1 2 3Rated Current (In) (A) 0.1, 0.3, 0.5, 1, 2, 3, 5, 7, 10, 15, 20, 25, 30, 40, 50, 60, 75, 100RatedVoltage (Ue)AC (V) 250 / 380DC (V) 80Operating Characteristics Instant(I), High(H), Middle(M), Low(L)Rated Ultimate Breaking Capacity(kA) sym KSC8321, IEC60934, UL1077AC 250 V 1.5 kADC 65 V 5 kANumber of operating cycleWithout Current (times) 4000With Current (times) 6000Dimension [mm]a 0.75 [19] 1.5 [38] 2.24 [57]b 2.5 [63.5]c 1.85 [47]d 0.83 [21]Weight [kg] 0.22 lbs[0.1] 0.44 lbs[0.2] 0.66 lbs[0.3]Automatic tripping device Hydraulic-Magnetic (HM)Connections Bolt on typeInternal CircuitSeries Trip(S) OParallel(P) OSwitch Only (O) ORelay Trip(R) OAccessoriesAux. Switch(W) OAlarm Switch (A) OVoltage Trip (V) OAmbient Temperature -400 C ~ 850CAux. Contact Capacity 250 VAC 3AApproval Standard UL CBP51B, CBP52BCircuit ProtectorStandard Plug TypeCBP5 B - Series2.5 [63.5]0.64 [15]2.06 [52.5]0.84 [21.4]0.75 [19]1.50 [38]0.75 [19]2.24 [57]1.50 [38]M3TapOFF34ON451.95 [49.5]1.85[47]0.14 [3.5]0.83[21]45A: M5 Bolt50A: M6 BoltSeries Trip (S)Only Switch (O)Aux Switch (W)Alarm Switch (A)0.18[4.6]2.06 [52.5]1.45 [36.9]0.76[19.3]1.50 [38.3]0.75[19]2.26 [57.6]1.50 [38]6- 0.14 [3.5] 4- 0.14 [3.5] 2- 0.14 [3.5]1.16 [29.5]0.90 [23]1 Pole 2 Pole 3 Pole1 Pole 2 Pole z3 PoleFeatures Various rated currents (0.1A ~ 45A) Indicate ON-OFF with Toggle Lever Various Optional Functions Adoption of ARC GRID with High Breaking Capacity Bolt, Terminal TypeApplications Various power distribution boards Telecommunication equipment UPS, Rectifer Inverter Welding Machines Machine Tools (Press, Discharger etc.) Dimension Inner Circuit Mounting Dimension56100 100 100S h Sc ho Sc ho l S ol S ol Stt r ee t r eet B t B t , Ber ge er ge f l nfel nfel d N d N d, NJ 07 J 07 J 07621 621 621Phone:(201)385-0500Fax:(201)385-0702THEALLPOWERSOURCEFor more information, please visit us at www.theallpowersource.com or email us at [email protected] ORDER CODECBP5 1 B HM15 A S - B: Product Series: Frame Volume10 100 AF550 AF330 AF: Poles1 1 Pole2 2 Pole3 3 Pole: TerminalsPAPlug Type: Quick connect terminals 6.3 x 0.8mmPSSrew Type: M4P Plug Type: Quick connect terminals 6.3 x 0.8mmS Srew Type: M4B Bolt Type: 0.1~45A : M5, 50~100A : M6: Handle (Only PA & PS)I1 Handle (2P, 3P) : For PA, PS type onlyH1 Pole = 1Handle,2Pole = 2Handle, 3Pole = 3Handle: Trip CharacteristicIInstantaneousHHighMMiddleL LowX Thereisnotripfunctionwithovercurrent, for open-closefunctiononly.S Middle of High - Middle: Rated CurrentPA, PS 0.1, 0.3, 0.5, 1, 2, 3, 5, 7, 10, 15, 20, 25, 30, 34P, S 0.1, 0.3, 0.5, 1, 2, 3, 5, 7, 10, 15, 20, 25, 30, 34, 40, 45B 0.1, 0.3, 0.5, 1, 2, 3, 5, 7, 10, 15, 20, 25, 30, 40, 50, 60, 75, 100: Rated VoltageAAC220, AC250, AC380 DDC 80V for B Type DC 65V for PA, PS, P, S Type: Internal CircuitSSeries TripW Auxiliary SwitchP Parallel Trip: It is available for B, PA & PS type onlyV Voltage trip: It is available B, PA & PS type onlyA Alarm Switch: It is available only for B type RRelay Trip: It is available for B, PA, & PS type onlyOSwitch OnlyInsulationBarrier1234561. OPERATING HANDLEItmakesthecontactopenandclose.When interruptingovercurrent,thehandleispositioned at OFF according to the standard reset method4. DE-ARCING MECHANISMThismechanisminterruptsshortcircuitcurrentby distributingandcoolingdownthearcthathastaken place between the contacts.2. ON-OFF MECHANISMConsistingofreasonablydesignedlink,latchand interruptingspring,itprovidessmoothon-ofoperation and long life span.5. MAGNETIC TRIPPING MECHANISMItdetectsovercurrentandshortcircuitcurrent,and opens the circuit.3. CONTACTContactismadeofsilveralloywithoutstanding conductivity, oxidation resistance and arc resistance.6. MOLDED CASEThecaseismadeofthermosettingresinwithexcellent insulation, arc resistance and wear resistance.PRINCIPLE OF OPERATIONNormal LoadUnder the normal load condition, theplungerandthearmature arepositionedasshowninthe pictureInitial State of OverloadIfovercurrentfows,theplunger isattractedbymagnetismand beginstomovetowardthepole, overcoming the resistance of the plunger spring and the silicon oil.Overload InterruptedWhentheplungerreachedthe pole, the intensity of magnetism increasesrapidlyandattracts thearmaturewhichattractsthe latch and opens the circuit.Short Circuit InterruptedIn case short circuit fows through the coil, even before the plunger moves,itcreatesapowerful magnetismwhichattractsthe armaturemomentarilyand interrupts short circuit current.STRUCTURE78