Cisco MDS 9148S Multilayer Hardware Installation GuideJuly 2014

Cisco Systems, Inc.www.cisco.com

Cisco has more than 200 offices worldwide. Addresses, phone numbers, and fax numbers are listed on the Cisco website at www.cisco.com/go/offices.

Text Part Number: OL-29583-01

Page 2: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.

THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY.

The following information is for FCC compliance of Class A devices: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to correct the interference at their own expense.

The following information is for FCC compliance of Class B devices: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If the equipment causes interference to radio or television reception, which can be determined by turning the equipment off and on, users are encouraged to try to correct the interference by using one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

Modifications to this product not authorized by Cisco could void the FCC approval and negate your authority to operate the product.

The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as part of UCB’s public domain version of the UNIX operating system. All rights reserved. Copyright © 1981, Regents of the University of California.

NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED “AS IS” WITH ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRACTICE.

IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF CISCO OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.

Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: www.cisco.com/go/trademarks. Third-party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (1721R)

Any Internet Protocol (IP) addresses and phone numbers used in this document are not intended to be actual addresses and phone numbers. Any examples, command display output, network topology diagrams, and other figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses or phone numbers in illustrative content is unintentional and coincidental.

© 2014 Cisco Systems, Inc. All rights reserved.

Page 3: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

OL-20185-01

C O N T E N T S

Preface

Audience ix

Organization ix

Document Conventions x

Related Documentation xii

Release Notes xii

Regulatory Compliance and Safety Information xii

Compatibility Information xii

Hardware Installation xii

Software Installation and Upgrade xiii

Cisco NX-OS xiii

Cisco Data Center Network Manager xiii

Command-Line Interface xiv

Intelligent Storage Networking Services Configuration Guides xiv

Troubleshooting and Reference xiv

C H A P T E R 1 Product Overview

Power Supplies 1-3

Fan Modules 1-4

Cisco MDS 9148S Multilayer Switch Ports 1-4

Switch LEDs 1-4

Supported SFP Transceivers 1-6

C H A P T E R 2 Installing the Cisco MDS 9148S Switch

Preinstallation 2-2

Installation Options 2-2

Installation Guidelines 2-3

Required Equipment 2-4

Unpacking and Inspecting the Switch 2-4

Front-Facing Installation 2-6

Installing the Switch in a Cabinet with Insufficient Front Clearance 2-9

Installing Front Rack-Mount Brackets for Cabinets with 26 Inches or Greater of Rail Spacings 2-11

iiiCisco MDS 9148S Multilayer Switch Hardware Installation Guide

Page 4: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Contents

Installing Front Rack-Mount Brackets for Cabinets with Less Than 26 Inches of Rail Spacings 2-12

Installing Cisco MDS 9148S Switch Rear-Facing into Cabinet 2-13

Grounding the Switch 2-17

Starting Up the Switch 2-18

Removing and Installing Components 2-20

Removing and Installing AC Power Supplies 2-21

Removing Power Supplies 2-21

Installing Power Supplies 2-22

Installing Power Supplies 2-23

Removing and Installing Fan Modules 2-23

Removing a Fan Module on the Cisco MDS 9148S Switch 2-23

Installing a Fan Module 2-25

Verifying the Fan Module 2-26

C H A P T E R 3 Connecting the Cisco MDS 9148S Switch

Preparing for Network Connections 3-1

Connecting the Console Port 3-1

Connecting the Console Port to a PC 3-2

Connecting a Modem to a Console Port 3-3

Connecting the 10/100 Ethernet Management Port 3-4

Connecting to a Fibre Channel Port 3-4

Removing and Installing SFP Transceivers 3-4

Installing an SFP Transceiver 3-5

Removing an SFP Transceiver 3-6

Removing and Installing Cables into SFP Transceivers 3-6

Installing a Cable into an SFP Transceiver 3-6

Removing a Cable from an SFP Transceiver 3-7

Maintaining SFP Transceivers and Fiber-Optic Cables 3-8

A P P E N D I X A Cabinet and Rack Installation

Cabinet and Rack Requirements A-1

General Requirements for Cabinets and Racks A-1

Requirements Specific to Perforated Cabinets A-2

Reference Perforated Cabinet A-2

Requirements Specific to Solid-Walled Cabinets A-3

Requirements Specific to Standard Open Racks A-3

Requirements Specific to Telco Racks A-3

Cisco MDS 9000 Family Telco and EIA Shelf Bracket A-3

ivCisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 5: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Contents

Rack-Mounting Guidelines A-4

Before Installing the Shelf Brackets A-5

Required Equipment A-5

Installing the Shelf Bracket Kit into a Two-Post Telco Rack A-5

Installing the Shelf Bracket Kit into a Four-Post EIA Rack A-7

Installing the Switch on the Shelf Brackets A-8

Removing the Shelf Bracket Kit (Optional) A-9

A P P E N D I X B Technical Specifications

Switch Specifications B-1

Power Specifications B-2

General Power Supply Specifications B-2

Power Supply Requirements and Heat Dissipation Specifications B-3

Connection Guidelines for AC-Powered Systems B-3

SFP Transceiver Specifications B-3

Cisco Fibre Channel SFP Transceivers B-4

General Specifications for Cisco Fibre Channel SFP Transceivers B-4

Environmental and Electrical Specifications for Cisco Fibre Channel SFP Transceivers B-5

Optical Specifications for Cisco CWDM SFP Transceivers B-5

A P P E N D I X C Cable and Port Specifications

Cables and Adapters C-1

Console Port C-2

Console Port Pinouts C-2

Connecting the Console Port to a Computer Using the DB-25 Adapter C-2

Connecting the Console Port to a Computer Using the DB-9 Adapter C-3

MGMT 10/100 Ethernet Port C-3

Supported Power Cords and Plugs C-4

Power Cords 4

Jumper Power Cord C-5

A P P E N D I X D Site Planning and Maintenance Records

Site Preparation Checklist D-1

Contact and Site Information D-3

Chassis and Network Information D-4

vCisco MDS 9148S Multilayer Switch Hardware Installation Guide

Page 6: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Contents

viCisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 7: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Preface

This preface describes the audience, organization, and conventions of the Cisco MDS 9148S Multilayer Switch Hardware Installation Guide. It also provides information on how to obtain related documentation.

AudienceTo use this installation guide, you need to be familiar with electronic circuitry and wiring practices and preferably be an electronic or electromechanical technician.

OrganizationThis guide is organized as follows:

Chapter Title Description

Chapter 1 Product Overview Provides an overview of the Cisco MDS 9148S Multilayer Fabric switch and its components.

Chapter 2 Installing the Cisco MDS 9148S Switch

Describes how to install the Cisco MDS 9148S Multilayer Fabric switch, and includes how to install power supplies and fan modules.

Chapter 1 Connecting the Cisco MDS 9148S Switch

Describes how to connect the Cisco MDS 9148S Multilayer Fabric switch.

Appendix 1 Cabinet and Rack Installation

Provides guidelines for selecting an enclosed cabinet, and the procedure for installing a switch using the optional Telco and EIA Shelf Bracket Kit.

Appendix 1 Technical Specifications

Lists the Cisco MDS 9148S Multilayer Fabric switch specifications, and includes safety information, site requirements, and power connections.

1Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 8: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Document ConventionsNotes use the following conventions:

Note Means reader take note. Notes contain helpful suggestions or references to material not covered in the manual.

Cautions use the following conventions:

Caution Means reader be careful. In this situation, you might do something that could result in equipment damage or loss of data.

Warnings use the following conventions:

Appendix 1 Cable and Port Specifications

Lists cable and port specifications for the Cisco MDS 9148S Multilayer Fabric switch.

Appendix Site Planning and Maintenance Records

Provides site planning and maintenance records.

Chapter Title Description

Warning This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. Statement 1071

Waarschuwing

Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van standaard maatregelen om ongelukken te voorkomen. Voor vertalingen van de waarschuwingen die in deze publicatie verschijnen, kunt u het document Regulatory Compliance and Safety Information (Informatie over naleving van veiligheids- en andere voorschriften) raadplegen dat bij dit toestel is ingesloten.

2Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 9: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Varoitus Tämä varoitusmerkki merkitsee vaaraa. Olet tilanteessa, joka voi johtaa ruumiinvammaan. Ennen kuin työskentelet minkään laitteiston parissa, ota selvää sähkökytkentöihin liittyvistä vaaroista ja tavanomaisista onnettomuuksien ehkäisykeinoista. Tässä julkaisussa esiintyvien varoitusten käännökset löydät laitteen mukana olevasta Regulatory Compliance and Safety Information -kirjasesta (määräysten noudattaminen ja tietoa turvallisuudesta).

Attention Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant causer des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez conscient des dangers posés par les circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents. Pour prendre connaissance des traductions d’avertissements figurant dans cette publication, consultez le document Regulatory Compliance and Safety Information (Conformité aux règlements et consignes de sécurité) qui accompagne cet appareil.

Warnung Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu einer Körperverletzung führen könnte. Bevor Sie mit der Arbeit an irgendeinem Gerät beginnen, seien Sie sich der mit elektrischen Stromkreisen verbundenen Gefahren und der Standardpraktiken zur Vermeidung von Unfällen bewußt. Übersetzungen der in dieser Veröffentlichung enthaltenen Warnhinweise finden Sie im Dokument Regulatory Compliance and Safety Information (Informationen zu behördlichen Vorschriften und Sicherheit), das zusammen mit diesem Gerät geliefert wurde.

Avvertenza Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle persone. Prima di lavorare su qualsiasi apparecchiatura, occorre conoscere i pericoli relativi ai circuiti elettrici ed essere al corrente delle pratiche standard per la prevenzione di incidenti. La traduzione delle avvertenze riportate in questa pubblicazione si trova nel documento Regulatory Compliance and Safety Information (Conformità alle norme e informazioni sulla sicurezza) che accompagna questo dispositivo.

Advarsel Dette varselsymbolet betyr fare. Du befinner deg i en situasjon som kan føre til personskade. Før du utfører arbeid på utstyr, må du vare oppmerksom på de faremomentene som elektriske kretser innebærer, samt gjøre deg kjent med vanlig praksis når det gjelder å unngå ulykker. Hvis du vil se oversettelser av de advarslene som finnes i denne publikasjonen, kan du se i dokumentet Regulatory Compliance and Safety Information (Overholdelse av forskrifter og sikkerhetsinformasjon) som ble levert med denne enheten.

3Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 10: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Related DocumentationThe documentation set for the Cisco MDS 9000 Family includes the following documents. To find a document online, use the Cisco MDS NX-OS Documentation Locator at:

http://www.cisco.com/en/US/docs/storage/san_switches/mds9000/roadmaps/doclocater.htm

Release Notes

• Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Releases

• Cisco MDS 9000 Family Release Notes for MDS SAN-OS Releases

• Cisco MDS 9000 Family Release Notes for Storage Services Interface Images

• Cisco MDS 9000 Family Release Notes for Cisco MDS 9000 EPLD Images

• Release Notes for Cisco MDS 9000 Family Fabric Manager

Regulatory Compliance and Safety Information

• Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family

Aviso Este símbolo de aviso indica perigo. Encontra-se numa situação que lhe poderá causar danos físicos. Antes de começar a trabalhar com qualquer equipamento, familiarize-se com os perigos relacionados com circuitos eléctricos, e com quaisquer práticas comuns que possam prevenir possíveis acidentes. Para ver as traduções dos avisos que constam desta publicação, consulte o documento Regulatory Compliance and Safety Information (Informação de Segurança e Disposições Reguladoras) que acompanha este dispositivo.

¡Advertencia! Este símbolo de aviso significa peligro. Existe riesgo para su integridad física. Antes de manipular cualquier equipo, considerar los riesgos que entraña la corriente eléctrica y familiarizarse con los procedimientos estándar de prevención de accidentes. Para ver una traducción de las advertencias que aparecen en esta publicación, consultar el documento titulado Regulatory Compliance and Safety Information (Información sobre seguridad y conformidad con las disposiciones reglamentarias) que se acompaña con este dispositivo.

Varning! Denna varningssymbol signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanligt förfarande för att förebygga skador. Se förklaringar av de varningar som förkommer i denna publikation i dokumentet Regulatory Compliance and Safety Information (Efterrättelse av föreskrifter och säkerhetsinformation), vilket medföljer denna anordning.

4Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 11: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Compatibility Information

• Cisco Data Center Interoperability Support Matrix

• Cisco MDS 9000 NX-OS Hardware and Software Compatibility Information and Feature Lists

• Cisco MDS NX-OS Release Compatibility Matrix for Storage Service Interface Images

• Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

• Cisco MDS NX-OS Release Compatibility Matrix for IBM SAN Volume Controller Software for Cisco MDS 9000

• Cisco MDS SAN-OS Release Compatibility Matrix for VERITAS Storage Foundation for Networks Software

Hardware Installation

• Cisco MDS 9700 Series Hardware Installation Guide

• Cisco MDS 9500 Series Hardware Installation Guide

• Cisco MDS 9250i Multiservice Switch Installation Guide

• Cisco MDS 9200 Series Hardware Installation Guide

• Cisco MDS 9124 and Cisco MDS 9134 Multilayer Fabric Switch Quick Start Guide

• Cisco MDS 9148 Multilayer Fabric Switch Quick Start Guide

• Cisco MDS 9148S Multilayer Fabric Switch Quick Start Guide

Software Installation and Upgrade

• Cisco MDS 9000 NX-OS Release 6.2(x) and SAN-OS 3(x) Software Upgrade and Downgrade Guide

• Cisco MDS 9000 Family Storage Services Interface Image Install and Upgrade Guide

• Cisco MDS 9000 Family Storage Services Module Software Installation and Upgrade Guide

Cisco NX-OS

• Cisco MDS 9000 Family NX-OS Licensing Guide

• Cisco MDS 9000 Family NX-OS Fundamentals Configuration Guide

• Cisco MDS 9000 Family NX-OS System Management Configuration Guide

• Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide

• Cisco MDS 9000 Family NX-OS Fabric Configuration Guide

• Cisco MDS 9000 Family NX-OS Quality of Service Configuration Guide

• Cisco MDS 9000 Family NX-OS Security Configuration Guide

• Cisco MDS 9000 Family NX-OS IP Services Configuration Guide

• Cisco MDS 9000 Family NX-OS Intelligent Storage Services Configuration Guide

• Cisco MDS 9000 Family NX-OS High Availability and Redundancy Configuration Guide

5Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 12: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

• Cisco MDS 9000 Family NX-OS Inter-VSAN Routing Configuration Guide

• Cisco MDS 9000 Family NX-OS Configuration Limits

Cisco Data Center Network Manager

• Cisco DCNM Fundamentals Guide

• Fabric Configuration Guide, Cisco DCNM for SAN

• High Availability and Redundancy Configuration Guide, Cisco DCNM for SAN

• Intelligent Storage Services Configuration Guide, Cisco DCNM for SAN

• Inter-VSAN Routing Configuration Guide, Cisco DCNM for SAN

• IP Services Configuration Guide, Cisco DCNM for SAN

• Quality of Service Configuration Guide, Cisco DCNM for SAN

• Security Configuration Guide, Cisco DCNM for SAN

• System Management Configuration Guide, Cisco DCNM for SAN

Command-Line Interface

• Cisco MDS 9000 Family Command Reference

Intelligent Storage Networking Services Configuration Guides

• Cisco MDS 9000 I/O Acceleration Configuration Guide

• Cisco MDS 9000 Family SANTap Deployment Guide

• Cisco MDS 9000 Family Data Mobility Manager Configuration Guide

• Cisco MDS 9000 Family Storage Media Encryption Configuration Guide

• Cisco MDS 9000 Family Secure Erase Configuration Guide

• Cisco MDS 9000 Family Cookbook for Cisco MDS SAN-OS

Troubleshooting and Reference

• Cisco NX-OS System Messages Reference

• Cisco MDS 9000 Family NX-OS Troubleshooting Guide

• Cisco MDS 9000 Family NX-OS MIB Quick Reference

• Cisco MDS 9000 Family NX-OS SMI-S Programming Reference

• Cisco MDS 9000 Family Fabric Manager Server Database Schema

6Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 13: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Cisco MDS 9148S

OL-20185-01

C H A P T E R 1

Product Overview

The Cisco MDS 9148S Multilayer Fabric Switch (DS-C9148S48PK9) is the next generation of the highly reliable and flexible Cisco MDS 9100 Series switches. A powerful compact one rack-unit (1RU) form factor can scale from 12 to 48 line-rate 16-Gbps Fibre Channel ports.

The Cisco MDS 9148S switch meets the requirements for a:

• Standalone storage area network (SAN) in small departmental storage environments

• Stop-of-the-rack switch in medium-sized redundant fabrics

• Edge switch in enterprise data center core-edge topologies

The Cisco MDS 9148S switch has the following major features:

• 12, 24, and 48, default licensed ports and an 12-port on-demand license

• 2-, 4-, 8- and, 16-Gbps full line rates

• Port interfaces that support field-replaceable, hot-swappable small form-factor pluggable (SFP) transceivers

• Redundant hot-swappable power supplies and fan trays, PortChannels for Inter-Switch Link (ISL) resiliency, and F-port channeling for resiliency on uplinks from a Cisco MDS 9148S operating in NPV mode

• Enterprise class features such as In-Service Software Upgrades (ISSU), Virtual SANs (VSANs), security features, and quality of service (QoS)

• PowerOn Auto Provisioning (POAP) to automate software image upgrades and configuration file installation on newly deployed switches

• Intelligent diagnostics

• Full compatibility with the Cisco MDS 9000 Family.

The front of the Cisco MDS 9148S switch contains the LEDs, the console and management ports, and 48 16-Gbps Fibre Channel Ports. See Figure 1.

1-7 Multilayer Switch Hardware Installation Guide

Page 14: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Product Overview

Figure 1 Front View of the Cisco MDS 9148S Multilayer Fabric Switch

The rear of the Cisco MDS 9148S switch contains the redundant power supplies, the AC power receptacle, and the fans. See Figure 2.

3527

42

1

2

4

3

6

5

7

1 Console port 5 USB port

2 Status LED 6 Ethernet port

3 Power supply LED 7 Fibre Channel ports

4 FAN LED

1-8Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 15: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Product Overview Power Supplies

Figure 2 Rear View of the Cisco MDS 9148S Multilayer Fabric Switch

This chapter describes hardware information about the Cisco MDS 9148S switch and its components, and it includes the following sections:

• Power Supplies, page 1-9

• Fan Modules, page 1-10

• Cisco MDS 9148S Multilayer Switch Ports, page 1-10

• Switch LEDs, page 1-10

• Supported SFP+ Transceivers, page 1-12

Power SuppliesThe Cisco MDS 9148S switch supports only AC power supplies. Each power supply provides sufficient power to maintain switch operation in the event of a single power supply failure. Power supplies are hot swappable and can be individually replaced without disruption to the system.

The power supply has two LEDs, INPUT OK and OUTPUT OK. Power supply status is also indicated on a front panel LED.

3527

47

1 432

6

5

7

8

1 Captive screw 5 Power module handle

2 On/Off switch 6 Fan module (fans 4 & 2)

3 Power receptable 7 Fan module (fans 3 & 1)

4 Power supply 2 8 Power supply 1

1-9Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 16: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Product Overview Fan Modules

Procedures for replacing and installing the power supplies are available in the Removing and Installing AC Power Supplies section.

Fan ModulesThe Cisco MDS 9148S switch supports two hot-swappable fan modules that allow the switches to continue to run if a fan module is removed, provided that the preset temperature thresholds have not been exceeded. You can swap out a fan module without having to bring the system down. Each fan module on the Cisco MDS 9148S switch has two fans.

Caution The Cisco MDS 9148S switch has internal temperature sensors that can shut down the system if the temperature at different points within the chassis exceed certain safety thresholds. To be effective, the temperature sensors require the presence of airflow; therefore, in the event a fan module is removed from the chassis, the Cisco MDS 9148S switch will shut down after five minutes to prevent potentially undetectable overheating. However, the switches will shut down sooner if the higher-level temperature threshold is exceeded. For normal operation, the Cisco MDS 9148S Switch requires four fans. Fan module status is also indicated on a front panel LED.

Procedures for replacing and installing the fan modules are available in the Removing and Installing Fan Modules section.

Cisco MDS 9148S Multilayer Switch PortsThe Cisco MDS 9148S switch provides host, target, and Inter-Switch Link (ISL) connectivity. It provides up to 48 autosensing and autonegotiating Fibre Channel ports capable of speeds of 2-, 4-, 8-, and 16-Gbps. The first 12 ports are licensed by default. On-Demand Port Activation Licensing allows expansion up to 48 ports, with additional ports available as an 12-port group.

Switch LEDsThe front panel of the Cisco MDS 9148S switch includes the LEDs shown in Figure 1-3. You can use the LEDs on this panel to quickly identify system status.

Note Cisco MDS 9148S switch LEDs do not indicate the port speed.

1-10Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 17: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Product Overview Switch LEDs

Figure 1-3 Cisco MDS 9148S Switch LEDs

Table 1-1 describes the front panel LEDs for the Cisco MDS 9148S switch.

1

2

3 4 5

3529

75

1 Switch status LED 4 10/100/1000 Ethernet management port link LED

2 Power supply LED 5 10/100/1000 Ethernet management port activity LED

3 Fan module status LED

Table 1-1 Switching Module LEDs

LED Status Description

Switch status Green The Ethernet port is connected other device.

Off The Ethernet port is not connected to other device.

Orange Blinking There is data transferring through this interface.

Off No data transferring.

Power supply status

Green Both power supplies are working.

Orange One power supply has failed or has been removed.

Red or all LEDs off Both power supplies have failed.

Fan module status

Green Both fan modules are working properly.

Red One or both fan modules have failed.

1-11Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 18: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Product Overview Supported SFP+ Transceivers

Supported SFP+ TransceiversThe following types of SFP+ transceivers are available from Cisco Systems and are supported on the Cisco MDS 9148S switch:

• Cisco MDS 4/8/16-Gbps Fibre Channel SW SFP+, LC: DS-SFP-FC16G-SW

• Cisco MDS 4/8/16-Gbps Fibre Channel LW SFP+, LC: DS-SFP-FC16G-LW

• Cisco MDS 2/4/8-Gbps Fibre Channel SW SFP+, LC: DS-SFP-FC8G-SW

• Cisco MDS 2/4/8-Gbps Fibre Channel LW SFP+, LC: DS-SFP-FC8G-LW

• Cisco MDS 2/4/8-Gbps Fibre Channel Extended Reach SFP+, LC: DS-SFP-FC8G-ER

• Cisco MDS 2/4/8-Gbps CWDM Long Distance SFP, LC: DS-CWDM8Gxxxx

• Cisco MDS 4/8/16-Gbps Fibre Channel LW SFP+, DWDM, SM, DDM, 13 dB, 40 km: DS-16G-ER-Dxxx

• Cisco MDS 4/8/16-Gbps Fibre Channel LW SFP+, CWDM, SM, DDM, 13 dB, 40 km: DS-16G-ER-Cxx

• Cisco MDS 4/8/16-Gbps Fibre Channel/FICON LW SFP+, DWDM, SM, DDM, 1550nm, 13 dB, 40 km: DS-16G-ER

• Cisco MDS 2/4/8-Gbps Fibre Channel LW SFP+, DWDM, SM, DDM, 80 km: DS-8G-ZR-Dxxx

• Cisco MDS 2/4/8-Gbps Fibre Channel LW SFP+, CWDM, SM, DDM, 23dB, 70 km: DS-8G-ZR-Cxx

• Cisco MDS 2/4/8-Gbps Fibre Channel LW SFP+, SM, DDM, 80 km: DS-8G-ZR

SFP transceivers are field-replaceable. You can use any combination of SFP transceivers that are supported by the switch. The only restrictions are that SWL transceivers must be paired with SWL transceivers, and LWL transceivers with LWL transceivers, and the cable must not exceed the stipulated cable length for reliable communications.

For the list of supported SFP transceivers, see the Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Releases. For more information about a specific Cisco SFP transceiver, see the “SFP Transceiver Specifications” section on page 1-4. SFP transceivers can be ordered separately or with the Cisco MDS 9148S Switch.

Port link Solid green Link is up.

Steady flashing green

Link is up (beacon used to identify port).1

Intermittent flashing green

Link is up (traffic on port).

Solid orange Link is disabled by software.

Flashing orange A fault condition exists.

1. The flashing green light turns on automatically when an external loopback is detected that causes the interfaces to be isolated. The flashing green light overrides the beacon mode configuration. The state of the LED is restored to reflect the beacon mode configuration after the external loopback is removed.

Table 1-1 Switching Module LEDs (continued)

LED Status Description

1-12Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 19: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Product Overview Supported SFP+ Transceivers

Note Use only Cisco SFP transceivers on the Cisco MDS 9148S switches. Each Cisco SFP transceiver is encoded with model information that enables the switch to verify that the SFP transceiver meets the requirements for the switch.

1-13Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 20: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Product Overview Supported SFP+ Transceivers

1-14Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 21: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Cisco MDS 9148S

OL-20185-01

C H A P T E R 2

Installing the Cisco MDS 9148S Switch

This chapter describes how to install the MDS 9148S switch and its components, and it includes the following information:

• Preinstallation, page 2-16

• Front-Facing Installation, page 2-19

• Installing the Switch in a Cabinet with Insufficient Front Clearance, page 2-21

• Grounding the Switch, page 2-26

• Grounding the Switch, page 2-26

• Starting Up the Switch, page 2-27

• Removing and Installing Components, page 2-29

Note Before you install, operate, or service the system, read the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family for important safety information.

Warning IMPORTANT SAFETY INSTRUCTIONS

This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. Statement 1071

SAVE THESE INSTRUCTIONS

Warning This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security. Statement 1017

Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030

2-15 Multilayer Switch Hardware Installation Guide

Page 22: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 2 Installing the Cisco MDS 9148S Switch Preinstallation

Note Each new switch requires a license; see the Cisco MDS 9000 Family NX-OS Licensing Guide for instructions on installing a license.

PreinstallationThis section includes the following information:

• Installation Options, page 2-16

• Installation Guidelines, page 2-16

• Required Equipment, page 2-18

• Unpacking and Inspecting the Switch, page 2-18

Installation Options

The MDS 9148S Switch can be installed using the following methods:

• In an open EIA rack, using:

– The rack-mount kit shipped with the switch

– The Telco and EIA Shelf Bracket Kit (an optional kit, purchased separately) in addition to the rack-mount kit shipped with the switch

• In a perforated or solid-walled EIA cabinet, using:

– The rack-mount kit shipped with the switch

– The Telco and EIA Shelf Bracket Kit (an optional kit, purchased separately) in addition to the rack-mount kit shipped with the switch

• In a two-post Telco rack, using:

– The Telco and EIA Shelf Bracket Kit (an optional kit, purchased separately) in addition to the front brackets shipped with the switch

For instructions on installing the switch using the rack-mount kit shipped with the switch, see the “Front-Facing Installation” section on page 2-19.

For instructions on installing the switch using the optional, separately purchased Telco and EIA Shelf Bracket Kit, see the “Cisco MDS 9000 Family Telco and EIA Shelf Bracket” section on page 1-3.

Note The Telco and EIA Shelf Bracket Kit is optional and is not provided with the switch. To order the kit, contact your switch provider.

Installation Guidelines

Follow these guidelines when installing the Cisco MDS 9148S Switch:

• Plan your site configuration and prepare the site before installing the switch. The recommended site planning tasks are listed in Appendix 1, “Site Planning and Maintenance Records.”

2-16Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 23: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 2 Installing the Cisco MDS 9148S Switch Preinstallation

• Ensure there is adequate space around the switch to allow for servicing the switch and for adequate airflow (airflow requirements are listed in Appendix 1, “Technical Specifications”).

• Ensure the air-conditioning meets the heat dissipation requirements listed in Appendix 1, “Technical Specifications.”

• Ensure the cabinet or rack meets the requirements listed in Appendix 1, “Cabinet and Rack Installation.”

Note If the front cabinet mounting rails are not offset from the front door or bezel panel by a minimum of 3 inch (7.6 cm), and a minimum of 5 inch. (12.7 cm) if cable management brackets are installed on the front of the chassis, the chassis should be mounted rear-facing to ensure the minimum bend radius for fiber-optic cables. See the “Installing the Switch in a Cabinet with Insufficient Front Clearance” section on page 2-21.

Note Jumper power cords are available for use in a cabinet. For more information, see the “Jumper Power Cord” section on page 1-6.

• Ensure the chassis is adequately grounded. If the switch is not mounted in a grounded rack, we recommend connecting both the system ground on the chassis and the power supply ground to an earth ground.

• Ensure the site power meets the power requirements listed in Appendix 1, “Technical Specifications.” If available, you can use an uninterrupted power supply (UPS) to protect against power failures.

Caution Avoid UPS types that use ferro-resonant technology. These UPS types can become unstable with systems such as the Cisco MDS 9000 Family, which can have substantial current draw fluctuations because of fluctuating data traffic patterns.

• Ensure that circuits are sized according to local and national codes.

For North America, the 300-W power supplies require a 20-A circuit. If you are using a 200- or 240-VAC power source in North America, the circuit must be protected by a two-pole circuit breaker.

Caution To prevent loss of input power, ensure the total maximum loads on the circuits supplying power to the switch are within current ratings for wiring and breakers.

• As you install and configure the switch, record the information listed in the “Site Planning and Maintenance Records” section on page 1-1.

• Use the following screw torques when installing the switch:

– Captive screws: 4 in-lb

– M3 screws: 4 in-lb

– M4 screws: 12 in-lb

– 10-32 screws: 20 in-lb

– 12-24 screws: 30 in-lb

2-17Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 24: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 2 Installing the Cisco MDS 9148S Switch Preinstallation

Required Equipment

Gather the following tools before beginning the installation:

• Number 1 Phillips screwdriver with torque capability

• 3/16-in. flat-blade screwdriver

• Tape measure and level

• ESD wrist strap or other grounding device

• Antistatic mat or antistatic foam

The following additional items (not found in the accessory kit) are required to ground the chassis:

• Grounding cable (6 AWG recommended), sized according to local and national installation requirements; the required length depends on the proximity of the switch to proper grounding facilities

• Crimping tool large enough to accommodate girth of lug

• Wire-stripping tool

Unpacking and Inspecting the Switch

Caution When handling switch components, wear an ESD strap and handle modules by the carrier edges only. An ESD socket is provided on the chassis. For the ESD socket to be effective, the chassis must be grounded through the power cable, the chassis ground, or the metal-to-metal contact with a grounded rack.

Tip Keep the shipping container in case the chassis requires shipping in the future.

Note If you purchased Cisco support through a Cisco reseller, contact the reseller directly. If you purchased support directly from Cisco, contact Cisco Technical Support at this URL: http://www.cisco.com/en/US/support/tsd_cisco_worldwide_contacts.html

Note The switch is thoroughly inspected before shipment. If any damage occurred during transportation or any items are missing, contact your customer representative immediately.

To inspect the shipment, follow these steps:

Step 1 Compare the shipment to the equipment list provided by your customer service representative and verify that you have received all items, including the following:

• Grounding lug kit

• Rack-mount kit

• ESD wrist strap

• Cables and connectors

2-18Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 25: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 2 Installing the Cisco MDS 9148S Switch Preinstallation

• Any optional items ordered

Step 2 Check for damage and report any discrepancies or damage to your customer service representative. Have the following information ready:

• Invoice number of shipper (see packing slip)

• Model and serial number of the damaged unit

• Description of damage

• Effect of damage on the installation

Front-Facing Installation

To install the switch in a cabinet or rack using the rack-mount kit provided with the switch, follow these steps:

Step 1 Install the front rack-mount bracket as follows:

a. Position one of the front rack-mount brackets against the side of the switch and align the screw holes. Then attach the bracket to the switch with the three M4 screws originally provided with the bracket.

b. Repeat with the other front rack-mount bracket on the other side of the switch.

Step 2 Install the C brackets as follows:

Note Two C brackets are shipped preinstalled on the switch, using three M3 screws per bracket. This installation step is only necessary if the C brackets were removed.

a. Position one of the C brackets against the side of the switch and align the screw holes. Attach the bracket to the switch with the three M3 screws originally provided with the bracket.

b. Repeat with the other C bracket on the other side of the switch.

Step 3 Install the slider rails in the rack. Position one of the slider rails against the rack mounting rails and align the screw holes as shown in Figure 2-1.

Step 4 Attach the slider rail using two 12-24 screws or two 10-32 screws, depending on the rack rail thread type. For racks with square holes, insert the 12-24 cage nuts in position behind the mounting holes in the slider rails.

a. Repeat with the other slider rail on the other side of the rack.

2-19Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 26: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 2 Installing the Cisco MDS 9148S Switch Preinstallation

b. Use the tape measure and level to verify that the rails are horizontal and at the same height.

Figure 2-1 Installing the Slider Rails

Figure 2-2 Installing the Notched Slider Rails

91

63

1

1824

59

2-20Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 27: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 2 Installing the Cisco MDS 9148S Switch Installing the Switch in a Cabinet with Insufficient Front Clearance

Step 5 Insert the switch into the rack:

a. By using both hands, position the switch with the back of the switch between the front rack-mounting rails as shown in Figure 2-3.

b. Align the two C brackets on either side of the switch with the slider rails installed in the rack. Slide the C brackets onto the slider rails, and then gently slide the switch all the way into the rack. If the switch does not slide easily, try realigning the C brackets on the slider rails.

Step 6 Stabilize the switch in the rack by attaching the front rack-mount brackets to the front rack-mounting rails:

a. Insert two screws (12-24 or 10-32, depending on rack type) and through the cage nuts and the holes in one of the front rack-mount brackets and into the threaded holes in the rack-mounting rail.

b. Repeat for the front rack-mount bracket on the other side of the switch.

If you are installing the optional cable guides, place the cable guides in front of the front rack-mount brackets, and then pass the screws through the cable guides, front rack-mount brackets, and mounting rail. You can install one or both cable guides; if installing a single cable guide, it can be installed on either side.

Figure 2-3 Attaching the Switch to the Rack

Installing the Switch in a Cabinet with Insufficient Front Clearance

This section describes how to use the rack-mount kit provided with the switch to install the Cisco MDS 9148S switch into a cabinet with insufficient front-facing clearance. The Cisco MDS 9148S switch is installed rear-facing to provide adequate clearance for the fiber-optic cables. This cabinet meets the requirements described in Appendix 1, “Cabinet and Rack Installation,” except the cabinet has less than three-inch clearance between the inside of the front door or bezel panel and the front cabinet mounting rails. This rear-facing installation is necessary to ensure that the minimum bend radius for the fiber-optic

3527

54

2-21Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 28: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 2 Installing the Cisco MDS 9148S Switch Installing the Switch in a Cabinet with Insufficient Front Clearance

cables is maintained. In these cabinets, the Cisco MDS 9148S switch is mounted backwards, with the fiber-optic cables facing toward the rear of the cabinet and the power supplies facing the front of the cabinet.

Caution If the rack is on wheels, ensure that the brakes are engaged or that the rack is otherwise stabilized.

The rack-mount kit provided with the switch contains the items listed in Table 2-1.

Table 2-1 Table 2-1 Cisco MDS 9148S Fabric Switch Rack-Mount Kit

Description Quantity

30- to 36-inch slider rails 2 per kit

24- to 30-inch slider rails 2 per kit

18- to 24-inch slider rails 2 per kit

Front rack-mount brackets 2 per kit

12-24 x 3/4-inch Phillips binder-head screws 10 per kit

10-32 x 3/4-inch Phillips binder-head screws 10 per kit

M4 x 6-mm Phillips flat-head screws 6 per kit

12-24 cage nuts 10 per kit

2-22Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 29: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 2 Installing the Cisco MDS 9148S Switch Installing the Switch in a Cabinet with Insufficient Front Clearance

Installing Front Rack-Mount Brackets for Cabinets with 26 Inches or Greater of Rail Spacings

The front rack-mount brackets for the Cisco MDS 9148S switch must be installed onto the switch prior to installing the switch into the cabinet. Follow these steps for cabinets with front-mounting rail to rear-mounting rail spacings greater or equal to 26 inches:

Step 1 Install the front rack-mount brackets as follows:

a. Position one of the front rack-mount brackets against the side of the switch and align the screw holes as shown in Figure 2-4. Then attach the bracket to the switch with the three M4 screws originally provided with the bracket.

b. Repeat with the other front-rack mount bracket on the other side of the switch.

Step 2 Install the C brackets as follows:

Note Two C brackets are shipped preinstalled on the switch, using three M3 screws per bracket. This installation step is only necessary if the C brackets were removed.

a. Position one of the C brackets against the side of the switch and align the screw holes. Attach the bracket to the switch with the three M3 screws originally provided with the bracket.

b. Repeat with the other C bracket on the other side of the switch.

Installing Front Rack-Mount Brackets for Cabinets with Less Than 26 Inches of Rail Spacings

The front rack-mount brackets for the Cisco MDS 9148S switch must be installed onto the switch prior to installing the switch into the cabinet. To install brackets for cabinets with front-mounting rail to rear-mounting rail spacings less than 26 inches that need to be mounted backwards to maintain adequate fiber-optic clearances, follow these steps:

Step 1 Install the front-rack mount brackets for cabinets with rail-to-rail spacings less than 26 inches as follows:

a. Position one of the front rack-mount brackets against the side of the switch and align the screw holes. Then attach the bracket to the switch with two of the three M4 screws originally provided with the bracket.

b. Repeat with the other front rack-mount bracket on the other side of the switch.

Note The front rack-mount bracket does not align with all three holes in the Cisco MDS 9148S switch in this configuration. The two screws are adequate to hold the weight of the Cisco MDS 9148S switch.

2-23Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 30: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 2 Installing the Cisco MDS 9148S Switch Installing the Switch in a Cabinet with Insufficient Front Clearance

Step 2 Install the C brackets as follows:

Note Two C brackets are shipped preinstalled on the switch, using three M3 screws per bracket. This installation step is only necessary if the C brackets were removed.

a. Position one of the C brackets against the side of the switch and align the screw holes. Then attach the bracket to the switch with the three M3 screws originally provided with the bracket.

b. Repeat with the other C bracket on the other side of the switch.

Installing Cisco MDS 9148S Switch Rear-Facing into Cabinet

To install a Cisco MDS 9148S switch rear-facing into a cabinet using the rack-mount kit provided with the switch (for cabinets with insufficient front-facing clearance), follow these steps:

Step 1 Install the notched slider rails in the rack:

a. Route the power cord through the open cutout at the end of one of the slider rails, and then let the cord dangle while you proceed with the next steps.

b. Position one of the slider rails against the front rack-mounting rails and align the screw holes. Attach them using two 12-24 screws or two 10-32 screws, depending on the rack rail thread type. For racks with square holes, first install the 12-24 cage nuts.

c. Repeat with the other slider rail on the other front side of the rack.

d. Use the tape measure and level to verify that the rails are horizontal and at the same height.

Step 2 Insert the switch into the rack:

a. Using both hands, position the switch with the back of the switch between the rear rack-mounting rails.

b. Align the two C brackets on either side of the switch with the slider rails installed in the rack. Slide the C brackets onto the slider rails and then gently slide the switch all the way into the rack. If the switch does not slide easily, try realigning the C brackets on the slider rails.

Step 3 Connect the power cord that you previously routed through the open cutout of the slider rail to the switch. Limit the length of the power cord between the back of the chassis and the rail opening.

Note If you failed to route the power cord through the open cutout of the slider rail as directed in Step 1, remove the switch and rails and remount the rails using the correct method. Do not connect the power cord by routing it over the top of the slider rail. This type of installation is hazardous.

2-24Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 31: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 2 Installing the Cisco MDS 9148S Switch Installing the Switch in a Cabinet with Insufficient Front Clearance

Step 4 Stabilize the switch in the rack by attaching the front rack-mount brackets to the rear rack-mounting rails:

a. Insert two screws (12-24 or 10-32, depending on rack type) through the holes in one of the front rack-mount brackets and into the threaded holes in the back rack-mounting rail (see Figure 2-4). For racks with square holes, first install the 12-24 cage nuts.

Figure 2-4 Attaching the Cisco MDS 9148S Switch (Rear-Facing) to the Cabinet

b. Repeat for the front rack-mount bracket on the other side of the switch.

Tip If the chassis exceeds the 1-RU space on the low side of the rack, you may have difficulty installing other equipment. In this situation, loosen the screws on the front and back rails of the chassis and raise it to the top of the RU space by pushing the chassis up until it cannot go any further. Then retighten the screws while keeping the chassis in the elevated position.

1824

64

Front cabinetmounting

rails

Rear cabinetmounting

rails

2-25Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 32: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 2 Installing the Cisco MDS 9148S Switch Grounding the Switch

Grounding the SwitchA grounding pad with two threaded M4 holes is provided on the chassis for attaching a grounding lug. Figure 2-5 shows the system ground location on the Cisco MDS 9148S switch.

Figure 2-5 Location of Switch Ground on the Cisco MDS 9148S Switch

Warning When installing or replacing the unit, the ground connection must always be made first and disconnected last. Statement 1046

Caution We recommend grounding the chassis, even if the rack is already grounded.

Note If the rack is less than 25-in. (635 mm) deep, the slider rails will cover the grounding hole. Therefore, the rack must either be grounded or at least 25-in. (635 mm) deep.

Caution All power supplies must be grounded. The receptacles of the AC power cables used to provide power to the chassis must be the grounding type, and the grounding conductors should connect to protective earth ground at the service equipment.

Consoleport

LEDs

Ethernetmanagement

port16 defaultlicensed

ports 32 on-demand ports

3528

29

Grounding lug

System grounding padWire

Screws (M4)

Groundingpad location

2-26Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 33: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 2 Installing the Cisco MDS 9148S Switch Starting Up the Switch

Note The grounding lug must be NRTL listed and compatible with copper conductors. Only copper conductors (wires) must be used and the copper conductor must comply with National Electrical Code (NEC) for ampacity.

Note Customers who require compliance to GR-1089-CORE bonding and grounding requirements, must use the ground conductor.

To attach the grounding lug and cable to the chassis, follow these steps:

Step 1 Use a wire-stripping tool to remove approximately 0.75 in. (19 mm) of the covering from the end of the grounding cable.

Step 2 Insert the stripped end of grounding cable into the open end of the grounding lug.

Step 3 Use the crimping tool to secure the grounding cable in the grounding lug.

Step 4 Remove the adhesive label from the grounding pad on the chassis.

Step 5 Place the grounding lug against the grounding pad so that there is solid metal-to-metal contact, and insert the two M4 screws with washers through the holes in the grounding lug and into the grounding pad.

Step 6 Ensure that the lug and cable do not interfere with other equipment.

Step 7 Prepare the other end of the grounding cable and connect it to an appropriate grounding point in your site to ensure adequate earth ground.

Starting Up the SwitchThis section provides instructions for powering up the switch and verifying component installation.

Caution During this procedure, wear grounding wrist straps to avoid ESD damage to the switch.

Note Do not connect the MGMT 10/100/1000 Ethernet port to the LAN until the initial switch configuration has been performed. For instructions on connecting to this port, see the “Connecting the Console Port” section on page 1-1.

To power up the switch and verify hardware operation, follow these steps:

Step 1 Verify that both power supplies and fan modules are installed and tighten any loose captive screws.

Step 2 Verify that the power switches on both power supplies are off. Then plug the power cables into the power supplies and arrange the cables so that they cannot be accidentally pulled out.

2-27Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 34: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 2 Installing the Cisco MDS 9148S Switch Starting Up the Switch

Note Depending on the outlet receptacle on your power distribution unit, you may need the optional jumper power cord to connect the Cisco MDS 9148S switch to your outlet receptacle. See the “Jumper Power Cord” section on page 1-6.

Step 3 Connect the other end of the power cables to an AC power source.

Step 4 Ensure that the switch is adequately grounded as described in the “Installing the Switch in a Cabinet with Insufficient Front Clearance” section on page 2-21, and that the power cables are connected to outlets that have the required AC power voltages (provided in the “Installing the Switch in a Cabinet with Insufficient Front Clearance” section on page 2-21).

Step 5 Flip the power switches on the power supplies to the on (|) position. The switch boots automatically.

Step 6 Listen for the fans; they should begin operating as soon as the switch is powered on.

Caution Do not operate the switch without a functioning fan module except for during the brief fan module replacement procedure. The Cisco MDS 9000 Family switches can operate for only a few minutes without any functioning fan modules before they begin to overheat.

Step 7 Verify that the LED behavior is as follows when the switch has finished booting:

• Fan status LED is green.

• Each power supply LED is green.

• The Switch status LED is green. If this LED is orange or red, then one or more environmental monitors is reporting a problem.

• The Ethernet port Link LEDs should not be on unless the cable is connected.

Note The LEDs for the Fibre Channel ports remain orange until the ports are enabled, and the LED for the MGMT 10/100/1000 Ethernet port remains off until the port is connected.

If any LEDs other than the Fibre Channel port LEDs are orange or red after the initial boot processes are complete, see the Cisco MDS 9000 Family Troubleshooting Guide.

Step 8 Try removing and reinstalling a component that is not operating properly. If it still does not operate correctly, contact your customer service representative for a replacement.

Note If you purchased Cisco support through a Cisco reseller, contact the reseller directly. If you purchased support directly from Cisco, contact Cisco Technical Support at this URL: http://www.cisco.com/en/US/support/tsd_cisco_worldwide_contacts.html

Step 9 Verify that the system software has booted and the switch has initialized without error messages. If any problems occur, see the Cisco MDS 9000 Family Troubleshooting Guide or the Cisco MDS 9000 Family System Messages Guide. If you cannot resolve an issue, contact your customer service representative.

Step 10 Complete the worksheets provided in Appendix 1, “Site Planning and Maintenance Records” for future reference.

2-28Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 35: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 2 Installing the Cisco MDS 9148S Switch Removing and Installing Components

Note A setup utility automatically launches the first time you access the switch and guides you through the basic configuration. For instructions about how to configure the switch and check module connectivity, see the Cisco Fabric Manager Fundamentals Configuration Guide.

Removing and Installing ComponentsThe Cisco MDS 9148S switch is shipped with two field-replaceable power supplies. Each power supply includes a fixed fan. The Cisco MDS 9148S switch has two field-replaceable fan modules.

This section provides the following information:

• Removing and Installing AC Power Supplies, page 2-30

• Removing and Installing Fan Modules, page 2-31

Warning Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. Statement 1034

Caution During this procedure, wear grounding wrist straps to avoid ESD damage to the switch.

Note The Cisco MDS 9148S Switch is only supported for operation with both power supplies and both fan modules installed, and with all fans working.

With two power supplies installed, if one power supply fails, the system can continue to function normally on a single healthy power supply. However, the failed power supply should be replaced as soon as possible to provide redundancy.

The fan modules are required to ensure proper cooling of the switches.

2-29Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 36: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 2 Installing the Cisco MDS 9148S Switch Removing and Installing Components

Figure 2-6 Rear View of the Cisco MDS 9148S Switch

Removing and Installing AC Power Supplies

This section provides instructions for removing and installing the AC power supplies for the Cisco MDS 9148S switch.

Removing Power Supplies

To remove a AC power supply, follow these steps:

Step 1 Turn the power switch to the off (0) position on the power supply that you are removing.

Step 2 Disconnect the power cord from the power source.

Step 3 Loosen the captive screw.

Step 4 Grasp the power supply handle and slide the power supply out of the switch.

Installing Power Supplies

To install the dual 300-W AC-input power supplies, follow these steps:

Step 1 Ensure that the system (earth) ground connection has been made.

3549

16

1 4 6

5

2 3

1 Power Supply 2 4 AC Power receptacle

2 Fan Module 2 (Fans 2 and 4) 5 Switch On/Off

3 Fan Module 1 (Fans 1 and 3) 6 Power Supply 1

2-30Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 37: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 2 Installing the Cisco MDS 9148S Switch Removing and Installing Components

Step 2 Make sure the power cord is disconnected before installing the power supply.

Step 3 Verify that the power switch is in the off (0) position on the power supply that you are installing.

Step 4 Slide the power supply into the power supply bay. Make sure that the power supply is fully seated in the bay.

Step 5 Tighten the power supply captive screw.

Step 6 Plug the power cord into the power supply.

Step 7 Connect the other end of the power cord to an AC-input power source.

Note Depending on the outlet receptacle on your power distribution unit, you may need the optional jumper power cord to connect the Cisco MDS 9148S switch to your outlet receptacle. See the “Jumper Power Cord” section on page 1-6.

Step 8 Turn the power switch to the on (|) position on the power supply.

Step 9 Verify power supply operation by checking that the power supply (P/S) LED in the front panel is green.

If the LED is not green, see the Cisco MDS 9000 Family Troubleshooting Guide.

Removing and Installing Fan Modules

This section provides instructions for removing and installing the fan modules for the Cisco MDS 9148S switch.

Removing a Fan Module on the Cisco MDS 9148S Switch

The fan module is designed to be removed and replaced while the system is operating without presenting an electrical hazard or damaging the system.

Caution The Cisco MDS 9000 Family has internal temperature sensors that can shut down the system if the temperature at different points within the chassis exceed certain safety thresholds. To be effective, the temperature sensors require the presence of airflow; therefore, in the event a fan module is removed from the chassis, the Cisco MDS 9000 Family will be shut down after five minutes to prevent potentially undetectable overheating. However, the switches will shut down sooner if the higher-level temperature threshold is exceeded.

Warning When removing the fan tray, keep your hands and fingers away from the spinning fan blades. Let the fan blades completely stop before you remove the fan tray. Statement 258

To remove the existing fan module, follow these steps:

Step 1 Locate the fan module in the back of the switch.

Step 2 Slide the seating tabs toward the center of the fan module.

Step 3 Grasp the fan module handle and pull it outward.

2-31Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 38: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 2 Installing the Cisco MDS 9148S Switch Removing and Installing Components

Step 4 Pull the fan module out of the switch and put it in a safe place.

Installing a Fan Module

To install a new fan module, follow these steps:

Step 1 Position the fan module with the LED oriented away from the back of the switch. Figure 2-7 shows the fan module for the Cisco MDS 9148S switch.

Step 2 Slide the fan module into the switch until it clicks into place.

Figure 2-7 shows the Cisco MDS 9148S fan module.

Figure 2-7 Cisco MDS 9148S Fan Module

1840

94

2-32Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 39: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 2 Installing the Cisco MDS 9148S Switch Removing and Installing Components

Verifying the Fan Module

To verify that the new fan module is installed correctly, follow these steps:

Step 1 Listen for the fans; you should immediately hear them operating. If you do not hear them, ensure that the fan module is inserted completely in the switch and the faceplate is flush with the switch back panel.

Step 2 Verify that the fan module LED is green. If the LED is orange, then one fan has failed in this fan module; if the LED is red, then both fans have failed in this fan module.

Step 3 Contact your customer service representative for assistance if, after several attempts, the fans do not operate or you experience trouble with the installation.

Note Verify that the transceiver and cable type both have LC connectors and are the required type for longwave or shortwave transmission and the required distances. The transceiver label generally lists the model and wavelength.

Note If you purchased this product through a Cisco reseller, contact the reseller directly for technical support. If you purchased this product directly from Cisco, contact Cisco Technical Support at this URL: http://www.cisco.com/en/US/support/tsd_cisco_worldwide_contacts.html

2-33Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 40: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 2 Installing the Cisco MDS 9148S Switch Removing and Installing Components

2-34Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 41: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Cisco MDS 9148S

OL-20185-01

C H A P T E R 1

Connecting the Cisco MDS 9148S Switch

The Cisco MDS 9148S switch provides the following types of ports:

• Console port (Interface Module)—An RS-232 port that you can use to create a local management connection.

• MGMT 10/100 Ethernet port (Interface Module)—An Ethernet port that you can use to access and manage the switch by IP address, such as through the CLI or Fabric Manager.

• Fibre Channel ports (Supervisor and Switching Modules)— Fibre Channel ports that you can use to connect to the SAN, or for in-band management.

This chapter describes how to connect the various components of the Cisco MDS 9148S switch, and it includes the following information:

• Preparing for Network Connections, page 1-35

• Connecting the Console Port, page 1-35

• Connecting the 10/100/1000 Ethernet Management Port, page 1-38

• Connecting to a Fibre Channel Port, page 1-38

Preparing for Network ConnectionsWhen preparing your site for network connections to the Cisco MDS 9148S switch, consider the following for each type of interface:

• Cabling required for each interface type

• Distance limitations for each signal type

• Additional interface equipment needed

Before installing the component, have all additional external equipment and cables available.

Connecting the Console PortThis section describes how to connect the RS-232 console port to a PC. The console port allows you to perform the following functions:

• Configure the switch from the CLI.

• Monitor network statistics and errors.

• Configure SNMP agent parameters.

1-35 Multilayer Switch Hardware Installation Guide

Page 42: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Connecting the Cisco MDS 9148S Switch Connecting the Console Port

• Download software updates to the switch or distribute software images residing in flash memory to attached devices.

The console port, located on the front panel, is shown in Figure 1-1.

Figure 1-1 Connecting the Console Cable

Connecting the Console Port to a PC

You can connect the console port to a PC serial port for local administrative access to the Cisco MDS 9148S switch.

Note The PC must support VT100 terminal emulation. The terminal emulation software—frequently a PC application such as HyperTerminal Plus—makes communication between the Cisco MDS 9148S switch and your PC possible during setup and configuration.

To connect the console port to a PC, follow these steps:

Step 1 Configure the baud rate and character format of the PC terminal emulation program to match the following management port default characteristics:

• 9600 baud

• 8 data bits

• 1 stop bit

• No parity

1-36Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 43: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Connecting the Cisco MDS 9148S Switch Connecting the Console Port

Step 2 Connect the supplied RJ-45 to DB-9 female adapter or RJ-45 to DB-25 female adapter (depending on your PC connection) to the PC serial port.

Step 3 Connect one end of the supplied console cable (a rollover RJ-45 to RJ-45 cable) to the console port. (See Figure 1-1.) Connect the other end to the RJ-45 to DB-9 (or RJ-45 to DB-25) adapter at the PC serial port.

Connecting a Modem to a Console Port

Caution Do not connect the console port to a modem while the switch is booting. Connect the console port to a modem either before powering the switch on or after the switch has completed the boot process.

To connect the console port to a modem before the switch is powered on, follow these steps:

Step 1 Connect the supplied console cable (a rollover RJ-45 to RJ-45 cable) to the console port (see Figure 1-1).

Step 2 Connect the other end of the console cable to the supplied RJ-45 to DB-25 adapter.

Step 3 Connect the RJ-45-to-DB-25 adapter to the DB-25 port on the modem.

Step 4 Power on the switch. The switch boots automatically, and the following default console port characteristics are applied to the modem connection:

• 9600 baud

• 8 data bits

• 1 stop bit

• No parity

• Default initialization string (ATE0Q1&D2&C1S0=1\015) if previously configured

Note For instructions on how to change these settings, see the Cisco Fabric Manager Fundamentals Configuration Guide for instructions on how to change these settings.

To connect the console port to a modem after the switch is powered on, follow these steps:

Step 1 Ensure that the system has completed booting and the system image is running.

Step 2 Connect the supplied console cable (a rollover RJ-45 to RJ-45 cable) to the console port (see Figure 1-1).

Step 3 Connect the other end of the console cable to the supplied RJ-45 to DB-25 adapter.

Step 4 Connect the RJ-45-to-DB-25 adapter to the DB-25 port on the modem.

Step 5 Initialize and configure the modem as specified in the Cisco Fabric Manager Fundamentals Configuration Guide and the Cisco NX-OS Fundamentals Configuration Guide.

1-37Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 44: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Connecting the Cisco MDS 9148S Switch Connecting the 10/100/1000 Ethernet Management Port

Connecting the 10/100/1000 Ethernet Management PortThe autosensing 10/100/1000 Ethernet management port is located on the left side of the front panel (labeled 10/100 MGMT), to the right of the Console port. This port is used for out-of-band management of the Cisco MDS 9148S switch.

Use a modular, RJ-45, straight-through UTP cable to connect the 10/100/1000 management Ethernet port to external hubs and switches. To connect to a router, use a crossover cable.

Connecting to a Fibre Channel PortThe Fibre Channel ports are compatible with LC-type fiber-optic SFP transceivers and cables (see “Removing and Installing Cables into SFP Transceivers” section on page 1-40). You can use these ports to connect to the SAN or for in-band management. For information about configuring the switch for in-band management, see the Cisco Fabric Manager Fundamentals Configuration Guide and the Cisco NX-OS Fundamentals Configuration Guide.

The Cisco MDS 9148S switch supports both Fibre Channel and Gigabit Ethernet protocols for SFP transceivers. Each transceiver must match the transceiver on the other end of the cable, and the cable must not exceed the stipulated cable length for reliable communications. SFP transceivers can be ordered separately or with the Cisco MDS 9148S switch.

Warning Class 1 laser product. Statement 1008

Warning Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into beams or view directly with optical instruments. Statement 1051

Caution Wear an ESD wrist strap connected to the chassis when handling transceivers. Keep optical connectors covered when not in use, and do not touch connector ends. The fiber-optic connectors must be free of dust, oil, and other contaminants.

This section includes the following information:

• Removing and Installing SFP Transceivers, page 1-38

• Removing and Installing Cables into SFP Transceivers, page 1-40

• Maintaining SFP Transceivers and Fiber-Optic Cables, page 1-42

Removing and Installing SFP Transceivers

Caution Removing and installing an SFP transceiver can shorten its useful life. Do not remove and insert SFP transceivers more often than is absolutely necessary.We recommend disconnecting cables before installing or removing SFP transceivers to prevent damage to the cable or transceiver.

1-38Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 45: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Connecting the Cisco MDS 9148S Switch Connecting to a Fibre Channel Port

Note Use only Cisco SFP transceivers on the Cisco MDS 9148S switch. Each Cisco SFP transceiver is encoded with model information that enables the switch to verify that the SFP transceiver meets the requirements for the switch.

The Cisco MDS 9148S switch supports SFP transceivers with the following two types of latching devices:

• Mylar tab latch (Figure 1-2)

• Bale-clasp latch (Figure 1-3)

Figure 1-2 SFP Transceiver with Mylar Tab Latch

Figure 1-3 SFP Transceiver with Bale-Clasp Latch

Installing an SFP Transceiver

To install an SFP transceiver, follow these steps:

Step 1 Attach an ESD-preventive wrist strap and follow its instructions for use.

Caution If the transceiver does not install easily, ensure it is correctly oriented and the tab or clasp are in the correct position before continuing.

Step 2 Remove the dust cover from the port cage.

Step 3 Remove the dust cover from the port end of the transceiver.

Step 4 Insert the transceiver into the port:

• If the transceiver has a mylar tab latch, orient the transceiver with the tab on the bottom, and then gently insert the transceiver into the port until it clicks into place.

• If the transceiver has a bale-clasp latch, orient the transceiver with the bale clasp on the bottom, close the bale clasp by pushing it up and over the transceiver, and then gently insert the transceiver into the port until it clicks into place.

6306

563

067

1-39Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 46: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Connecting the Cisco MDS 9148S Switch Connecting to a Fibre Channel Port

Step 5 Insert or leave the dust plug in the cable end of the transceiver if a cable is not being installed in the transceiver.

Removing an SFP Transceiver

To remove an SFP transceiver, follow these steps:

Step 1 Attach an ESD-preventive wrist strap and follow its instructions for use.

Step 2 Perform these steps if cable is installed in the transceiver:

a. Record the cable and port connections for later reference.

b. Press the release latch on the cable, grasp the connector near the connection point, and gently pull the connector from the transceiver.

c. Insert a dust plug into the connector on the cable.

d. Insert a dust plug into the cable end of the transceiver.

Tip If the transceiver does not remove easily in the next step, push the transceiver all the way back in and then ensure that the latch is in the correct position before continuing.

Step 3 Remove the transceiver from the port:

• If the transceiver has a mylar tab latch, gently pull the tab straight out (do not twist), and then pull the transceiver out of the port.

• If the transceiver has a bale-clasp latch, open the clasp by pressing it downwards, and then pull the transceiver out of the port.

Step 4 Insert a dust cover into the port end of the transceiver and place the transceiver on an antistatic mat or into a static shielding bag if you plan to return it to the factory.

Step 5 Protect the optical cage by inserting a clean cover if another transceiver is not being installed.

Removing and Installing Cables into SFP Transceivers

Caution To prevent damage to the fiber-optic cables, do not place more tension on them than the rated limit and do not bend to a radius of less than one inch if there is no tension in the cable, or two inches if there is tension in the cable.

Installing a Cable into an SFP Transceiver

Caution To prevent possible damage to the cable or transceiver, install the transceiver in the port before installing the cable in the transceiver.

1-40Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 47: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Connecting the Cisco MDS 9148S Switch Connecting to a Fibre Channel Port

To install a cable into a transceiver, follow these steps:

Step 1 Attach an ESD-preventive wrist strap and follow its instructions for use.

Step 2 Remove the dust cover from the connector on the cable.

Step 3 Remove the dust cover from the cable end of the transceiver.

Step 4 Align the cable connector with the transceiver and insert the connector into the transceiver until it clicks into place. (See Figure 1-4).

Figure 1-4 Connecting the LC-Type Cable to a Fibre Channel Port

Caution If the cable does not install easily, ensure it is correctly oriented before continuing.

For instructions on verifying connectivity, see the Cisco Fabric Manager Fundamentals Configuration Guide and the Cisco NX-OS Fundamentals Configuration Guide.

Removing a Cable from an SFP Transceiver

Caution When pulling a cable from a transceiver, grip the body of the connector. Do not pull on the jacket sleeve, because this can compromise the fiber-optic termination in the connector.

Caution If the cable does not remove easily, ensure that any latch present on the cable has been released before continuing.

To remove the cable, follow these steps:

Step 1 Attach an ESD-preventive wrist strap and follow its instructions for use.

Step 2 Press the release latch on the cable, grasp the connector near the connection point, and gently pull the connector from the transceiver.

Step 3 Insert a dust plug into the cable end of the transceiver.

LC plug

SFP module

9168

1

1-41Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 48: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Connecting the Cisco MDS 9148S Switch Connecting to a Fibre Channel Port

Step 4 Insert a dust plug onto the end of the cable.

Maintaining SFP Transceivers and Fiber-Optic Cables

SFP transceivers and fiber-optic cables must be kept clean and dust-free to maintain high signal accuracy and prevent damage to the connectors. Attenuation (loss of light) is increased by contamination, and it should be kept below 0.35 dB.

Follow these maintenance guidelines:

• SFP transceivers are static sensitive. To prevent ESD damage, wear an ESD-preventive wrist strap that is connected to the chassis.

• Do not remove and insert a transceiver more often than necessary. Repeated removals and insertions can shorten its useful life.

• Keep all optical connections covered when not in use. If they become dusty, clean before using to prevent dust from scratching the fiber-optic cable ends.

• Do not touch ends of connectors. This prevents fingerprints and other contamination of the connectors.

• Clean regularly; the required frequency of cleaning depends upon the environment. In addition, clean connectors if they are exposed to dust or accidentally touched. Both wet and dry cleaning techniques can be effective; refer to your site’s fibre-optic connection cleaning procedures.

• Inspect routinely for dust and damage. If damage is suspected, clean and then inspect fiber ends under a microscope to determine if damage has occurred.

1-42Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 49: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Cisco MDS 9148S

OL-20185-01

C H A P T E R 1

Cabinet and Rack Installation

This appendix includes the following information:

• Cabinet and Rack Requirements, page 1-43

• Cisco MDS 9000 Family Telco and EIA Shelf Bracket, page 1-45

Cabinet and Rack RequirementsThis section provides the Cisco MDS 9000 Family requirements for the following types of cabinets and racks, assuming an external ambient air temperature range of 0 to 40°C:

• Standard perforated cabinets

• Solid-walled cabinets with a roof fan tray (bottom to top cooling)

• Standard open racks

• Telco racks

Note If you are selecting an enclosed cabinet, we recommend one of the thermally validated types listed above: standard perforated or solid-walled with a fan tray.

General Requirements for Cabinets and Racks

The cabinet or rack must be one of the following rack types:

• Standard 19-in. four-post EIA cabinet or rack, with mounting rails that conform to English universal hole spacing per section 1 of ANSI/EIA-310-D-1992. See the “Requirements Specific to Perforated Cabinets” section on page 1-44 and “Requirements Specific to Solid-Walled Cabinets” section on page 1-45.

• Standard two-post telco rack, with mounting rails that conform to English universal hole spacing per section 1 of ANSI/EIA-310-D-1992. See the “Requirements Specific to Telco Racks” section on page 1-45.

The cabinet or rack must also meet the following requirements:

• The minimum vertical rack space per chassis should be 1 RU (rack unit), equal to 1.75 in. (4.4 cm).

• The width between the rack-mounting rails must be at least 17.75 in. (45.1 cm). For four-post EIA racks, this is the distance between the two front rails.

1-43 Multilayer Switch Hardware Installation Guide

Page 50: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Cabinet and Rack Installation Cabinet and Rack Requirements

• For four-post EIA cabinets (perforated or solid-walled):

– The minimum spacing for bend radius for fiber-optic cables should have the front mounting rails of the cabinet offset from the front door by a minimum of 3 in. (7.6 cm), and a minimum of 5 in. (12.7 cm) if cable management brackets are installed on the front of the chassis.

– The distance between the outside face of the front mounting rail and the outside face of the back mounting rail should be 23.5 to 34.0 in. (59.7 to 86.4 cm) to allow for rear bracket installation.

– There should be a minimum of 2.5 in. (6.4 cm) of clear space between the side edge of the chassis and the side wall of the cabinet. No sizeable flow obstructions should be immediately in the way of the chassis air intake or exhaust vents.

Note Optional jumper power cords are available for use in a cabinet. See the “Jumper Power Cord” section on page 1-6.

Requirements Specific to Perforated Cabinets

In addition to the requirements listed in the “General Requirements for Cabinets and Racks” section on page 1-43, perforated cabinets must meet the following requirements:

• The front and rear doors must have at least a 60 percent open area perforation pattern, with at least 15 sq. in. of open area per rack unit of door height.

• We recommend that the roof be perforated with at least 20 percent open area, unless the cabinet only contains Cisco MDS 9148S switch, in which case the roof does not have to be perforated.

• We recommend an open or perforated cabinet floor to enhance cooling but it is not required.

Reference Perforated Cabinet

A perforated cabinet that conforms to the above requirements is available from Rittal Corporation:

Rittal Corporation

One Rittal Place

Springfield, OH 45504

Phone: (800) 477-4000

Cabinet P/N: Rittal 9969427

Cabinet description: PS-DK/OEM Cabinet Assembly, 1998 x 600 x 1000 (H x W x D) (42U)

1-44Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 51: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Cabinet and Rack Installation Cisco MDS 9000 Family Telco and EIA Shelf Bracket

Requirements Specific to Solid-Walled Cabinets

In addition to the requirements listed in the “General Requirements for Cabinets and Racks” section on page 1-43, solid-walled cabinets must meet the following requirements:

• A roof-mounted fan tray and an air cooling scheme in which the fan tray pulls air in at the bottom of the cabinet and exhausts it out the top, with a minimum of 500 cfm of airflow exiting the cabinet roof through the fan tray.

• Nonperforated (solid and sealed) front and back doors and side panels so that air travels predictably from bottom to top.

• The overall cabinet depth should be 36 to 42 in. (91.4 to 106.7 cm) to allow the doors to close and adequate airflow.

• A minimum of 150 sq. in. (968 sq. cm) of open area at the floor air intake of the cabinet.

• The lowest piece of equipment should be installed a minimum of 1.75 in. (4.4 cm) above the floor openings to prevent blocking the floor intake.

Requirements Specific to Standard Open Racks

In addition to the requirements listed in the “General Requirements for Cabinets and Racks” section on page 1-43, if mounting the chassis in an open rack (no side panels or doors), ensure that the rack meets the following requirements:

• Width between two front mounting rails: minimum of 17.75 in. (45.1 cm)

• Minimum vertical rack space per chassis: 1 rack unit (RU), equal to 1.75 in. (4.4 cm)

• The distance between the outside face of the front mounting rail and the outside face of the back mounting rail should be 23.5 to 34.0 in. (59.7 to 86.4 cm) to allow for rear bracket installation.

• The distance between the chassis air vents and any walls should be 2.5 in. (6.4 cm).

Requirements Specific to Telco Racks

In addition to the requirements listed in the “General Requirements for Cabinets and Racks” section on page 1-43, telco racks should meet the following requirements:

• The width of the rack between the two rack-mounting rails should be at least 17.75 in. (45.1 cm).

• The distance between the chassis air vents and any walls should be 2.5 in. (6.4 cm).

Cisco MDS 9000 Family Telco and EIA Shelf BracketThe optional Telco and EIA Shelf Bracket Kit (part number DS-SHELF=) can temporarily or permanently support the Cisco MDS 9148S switch during installation. Once the front rack-mount brackets are securely attached to the rack-mounting rails, the shelf bracket can be removed.

This kit supports the following configurations:

• A Cisco MDS 9148S Switch in a two-post Telco rack

• A Cisco MDS 9148S Switch in a four-post EIA rack

1-45Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 52: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Cabinet and Rack Installation Cisco MDS 9000 Family Telco and EIA Shelf Bracket

Note This optional kit is not provided with the switch; to order the kit, contact your switch supplier.

This section describes the procedure for installing a Cisco MDS 9148S switch in a rack or cabinet using the optional Telco and EIA Shelf Bracket Kit. This section includes the following information:

• Rack-Mounting Guidelines, page 1-46

• Before Installing the Shelf Brackets, page 1-47

– Required Equipment, page 1-47

– Installing the Shelf Bracket Kit into a Four-Post EIA Rack, page 1-49

– Installing the Shelf Bracket Kit into a Two-Post Telco Rack, page 1-47

– Installing the Switch on the Shelf Brackets, page 1-50

– Removing the Shelf Bracket Kit (Optional), page 1-51

Rack-Mounting Guidelines

Caution If the rack is on wheels, ensure that the brakes are engaged or the rack is otherwise stabilized.

Caution If installing this kit in an EIA rack, attach the switch to all four rack-mounting rails; the EIA rails may not be thick enough to prevent flexing of the shelf brackets if only two rails are used.

Before rack-mounting the chassis, ensure that the cabinet or rack meets the following requirements:

• The specifications listed in the “Cabinet and Rack Requirements” section on page 1-43.

• The depth of the rack between the front and rear mounting rails is at least 18 in. (45.7 cm) but less than or equal to 30 in. (76.2 cm). This is specific to four-post EIA cabinets or racks.

• The airflow and cooling are adequate and there is sufficient clearance around the air vents on the switch, as described in Appendix 1, “Technical Specifications.” This is particularly important to verify if you are installing the switch in an enclosed cabinet.

• The rack has sufficient vertical clearance for the chassis plus two rack units for the shelf brackets, and any desired clearance for the installation process.

• The rack meets the minimum rack load ratings per rack unit (RU) listed in the following table.

Rack Type MDS 9148S

EIA (4-post) 7.5 lb

Telco (2 post) 15 lb

1-46Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 53: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Cabinet and Rack Installation Cisco MDS 9000 Family Telco and EIA Shelf Bracket

Before Installing the Shelf Brackets

Before installing the shelf brackets, inspect the contents of your kit. Table 1-1 lists the contents of the shelf bracket kit.

Required Equipment

You need the following equipment for this installation:

• Number 2 Phillips screwdriver

• Tape measure and level (to ensure shelf brackets are level)

Installing the Shelf Bracket Kit into a Two-Post Telco Rack

Figure 1-1 shows the installation of the shelf bracket kit into a two-post Telco rack.

Figure 1-1 Installing the Shelf Bracket Kit into a Telco Rack

Table 1-1 Contents of Shelf Bracket Kit

Quantity Part Description

2 Slider brackets

2 Shelf brackets

1 Crossbar

2 10-32 x 3/8-in. Phillips pan-head screws

16 12-24 x 3/4-in. Phillips screws

16 10-24 x 3/4-in. Phillips screws

1 Rack-mounting rail (2x) 3 10-32 screws (2x)

2 Shelf bracket (2x) 4 Crossbar

12

3

4

1050

88

1-47Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 54: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Cabinet and Rack Installation Cisco MDS 9000 Family Telco and EIA Shelf Bracket

To install the shelf brackets in a Telco rack, follow these steps:

Step 1 Position a shelf bracket inside a rack-mounting rail as shown in Figure 1-1 and align the screw holes at the front of the shelf bracket with the holes in the rack-mounting rail. Then attach the shelf bracket to the rack-mounting rail using a minimum of four 12-24 or 10-24 screws.

Note The bottom hole of the shelf bracket should align with the bottom hole of a rack unit on the rack-mounting rail (the hole immediately above the 1/2-in. spacing).

Step 2 Repeat with the other shelf bracket.

Step 3 Verify that the shelf brackets are at the same height (using the level or tape measure as desired).

Step 4 Attach the crossbar to the rear of the shelf brackets as shown in Figure 1-1, using the 10-32 screws.

1-48Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 55: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Cabinet and Rack Installation Cisco MDS 9000 Family Telco and EIA Shelf Bracket

Installing the Shelf Bracket Kit into a Four-Post EIA Rack

Figure 1-2 shows the installation of the shelf bracket kit into a four-post EIA rack.

Figure 1-2 Installing the Shelf Bracket Kit into an EIA Rack

To install the shelf brackets in an EIA rack, follow these steps:

Step 1 Position a shelf bracket inside the rack-mounting rails as shown in Figure 1-2. Align the screw holes at the front of the shelf bracket with the holes in the front rack-mounting rail. Then attach the shelf bracket to the front rack-mounting rail using a minimum of four 12-24 or 10-24 screws.

Note The bottom hole of the shelf bracket should align with the bottom hole of a rack unit on the rack-mounting rail (the hole immediately above the 1/2-in. spacing).

Step 2 Repeat with the other shelf bracket.

Step 3 Verify that the shelf brackets are at the same height (using the level or tape measure as desired).

1 Rack-mounting rail (4x) 4 Crossbar

2 Shelf bracket (2x) 5 10-32 screws (2x)

3 Slider rail (2)

1

2

3

5

4

1050

87

1-49Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 56: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Cabinet and Rack Installation Cisco MDS 9000 Family Telco and EIA Shelf Bracket

Step 4 Attach the crossbar to the shelf brackets as shown in Figure 1-2, using the 10-32 screws.

Step 5 Insert the slider rails into the shelf brackets as shown in Figure 1-2. Then attach them to the rear rack-mounting rails using a minimum of four 12-24 or 10-24 screws.

Installing the Switch on the Shelf Brackets

This section provides general instructions for installing the switch on top of the shelf brackets. For detailed installation instructions, see the “Front-Facing Installation” section on page 2-19.

Warning This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security. Statement 1017

Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030

Note Before you install, operate, or service the system, refer to the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family for important safety information.

To install the switch on top of the shelf brackets, follow these steps:

Step 1 Verify that the shelf brackets are level and securely attached to the rack-mounting rails, the crossbar is securely attached to the shelf brackets, and the rack is stabilized.

Step 2 Slide the switch onto the shelf brackets, ensuring that it is squarely positioned.

Step 3 Attach the switch to the rack-mounting rails. See the “Front-Facing Installation” section on page 2-19.

Caution We recommend grounding the chassis, even if the rack is already grounded. A grounding pad with two threaded M4 holes is provided on the chassis for attaching a grounding lug.

Note The grounding lug must be NRTL listed and compatible with copper conductors. Only copper conductors (wires) must be used and the copper conductor must comply with National Electrical Code (NEC) for ampacity.

1-50Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 57: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Cabinet and Rack Installation Cisco MDS 9000 Family Telco and EIA Shelf Bracket

Removing the Shelf Bracket Kit (Optional)

The shelf bracket kit can be removed after the Cisco MDS 9148S switch has been installed in a four-post EIA rack, and both front rack-mount brackets and both C brackets are securely attached to the rack-mounting rails.

To remove the shelf bracket kit, follow these steps:

Step 1 Remove the screws fastening the slider brackets to the rear rack-mounting rails, and then slide the slider brackets out of the shelf brackets.

Step 2 Remove the screws fastening the crossbar to the shelf brackets, and then remove the crossbar.

Step 3 Remove the screws fastening the shelf brackets to the front rack-mounting rails and remove the shelf brackets from the rack.

1-51Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 58: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Cabinet and Rack Installation Cisco MDS 9000 Family Telco and EIA Shelf Bracket

1-52Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 59: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Cisco MDS 9148S

OL-20185-01

C H A P T E R 1

Technical Specifications

This appendix includes the following technical specifications for the Cisco MDS 9148S switch:

• Switch Specifications, page 1-53

• Power Specifications, page 1-54

• SFP Transceiver Specifications, page 1-56

Switch SpecificationsTable 1-1 lists the environmental specifications for the Cisco MDS 9148S switch.

Table 1-2 lists the physical specifications for the Cisco MDS 9148S switch.

Table 1-1 Environmental Specifications for the Cisco MDS 9148S switch

Description Specification

Temperature, ambient operating 32 to 104°F (0 to 40°C)

Temperature, ambient nonoperating and storage

-40 to 158°F (-40 to 70°C)

Humidity (RH), ambient (noncondensing) operating

10 to 90%

Humidity (RH), ambient (noncondensing) nonoperating and storage

5 to 95%

Altitude, operating -197 to 6500 ft (-60 to 2000 m)

Noise levels 60 dB

Table 1-2 Cisco MDS 9148S Switch Specifications

Description Specification

Cisco MDS 9148S Switch Dimensions

Width = 17.16 inch (43.59 centimeter)

Height = 1.72 inch (4.37 centimeter)

Depth = 16.34 inch (41.50 centimeter)

Rack Unit (RU) Chassis requires 1 RU (1.75 in. or 4.45 cm)

1-53 Multilayer Switch Hardware Installation Guide

Page 60: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Technical Specifications Power Specifications

Power SpecificationsThis section includes the following information:

• General Power Supply Specifications, page 1-54

• Power Supply Requirements Specifications, page 1-55

• Connection Guidelines for AC-Powered Systems, page 1-55

General Power Supply Specifications

Table 1-3 lists the specifications for the Cisco MDS 9148S switch AC input power supply.

Weight 19.84 lb (9 kg) (with two fan modules and two power supplies installed)

Power Supply (fixed)

300-W AC for each power supply

Part Number: DS-C48S-300AC

Power cord: Notched C15 socket connector connecting to C16 plug on power supply

100 to 240V AC (10% range)

50 to 60 Hz (nominal)

Airflow Back to front.

200 linear feet per minute (LFM) through the system and a maximum of 380 LMDM.

Cisco recommends that you maintain a minimum air space of 2.5 in. (6.4 cm) between walls and chassis air vents and a minimum horizontal separation of 6 in. (15.2 cm) between two chassis to prevent overheating.

Table 1-2 Cisco MDS 9148S Switch Specifications (continued)

Description Specification

Table 1-3 Cisco MDS 9148S Switch AC Input Power Supply Specifications

AC Input Power Supply Specification

AC input voltage Minimum = 90 VAC

Nominal = 100 to 240 VAC

Maximum = 264 VAC

AC input current rating (maximum)

4.7 A at 85 VAC3.6 A at 110 VAC1.8 A at 220 VAC

Note For plug current rating, see the “Jumper Power Cord” section on page 1-6.

AC input frequency Nominal = 50 to 60 Hz

1-54Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 61: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Technical Specifications Power Specifications

Power Supply Requirements Specifications

Table 1-4 provides a sample calculation of power for the Cisco MDS 9148S switch AC input power supply.

Tip To prevent a loss of input power, ensure that the total maximum load on each circuit supplying the power supply is within the current ratings of the wiring and breakers.

Connection Guidelines for AC-Powered Systems

For connecting the Cisco MDS 9148S switch AC power supplies to the site power source, follow these basic guidelines:

• Each power supply should have its own dedicated branch circuit.

• For international, circuits should be sized according to local and national codes.

• The AC power receptacles used to plug in the chassis must be the grounding type. The grounding conductors that connect to the receptacles should connect to protective earth ground at the service equipment.

Power supply output capacity 300 W

Power supply output voltage 12 V +/- 6% up to 25 A

Output holdup time 20ms when input > 100 VAC

Table 1-3 Cisco MDS 9148S Switch AC Input Power Supply Specifications

AC Input Power Supply Specification

Table 1-4 Power and Heat Dissipation for AC Input Power Supply

Cisco MDS 9148S Switch AC Power (Volt) AC Power (Watt)

220 125.08

Typical Case 220 125.08

110 127.72

50C/NV 220 144.8

110 145.87

50C/HV 220 155.3

110 158.48

Worst Case 220 183.11

110 187.66

1-55Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 62: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Technical Specifications SFP Transceiver Specifications

SFP Transceiver SpecificationsThe Cisco MDS 9148S switch is compatible with SFP transceivers and cables that have LC connectors. Each transceiver must match the transceiver on the other end of the cable in terms of wavelength, and the cable must not exceed the stipulated cable length for reliable communications.

Cisco SFP transceivers provide the uplink interfaces, laser transmit (TX), and laser receive (RX), and they support 850 to 1610 nm nominal wavelengths, depending upon the transceiver.

Use only Cisco SFP transceivers on the Cisco MDS 9148S switch. Each Cisco SFP transceiver is encoded with model information that enables the switch to verify that the SFP transceiver meets the requirements for the switch. For the list of supported SFP transceivers, see the release notes.

For details of SFP transceivers see the data sheet at the following location:

http://www.cisco.com/en/US/prod/collateral/ps4159/ps6409/ps4358/product_data_sheet09186a00801bc698.html

This section provides the following information:

• Cisco Fibre Channel SFP+ Transceivers, page 1-56

• Optical Specifications for Cisco CWDM SFP Transceivers, page 1-60

For information about safety, regulatory, and standards compliance, see the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family.

Cisco Fibre Channel SFP+ Transceivers

Table 1-5 lists the Fibre Channel SFP+ transceivers available through Cisco Systems for the Cisco MDS 9148S switch.

General Specifications for Cisco Fibre Channel 16 Gbps SFP+ Transceivers

Table 1-6 summarizes cabling specifications for 16 Gbps.

Table 1-5 Cisco Fibre Channel SFP + Transceivers for the Cisco MDS 9148S Switch

Part Number Description Type

DS-SFP-FC16G-SW Cisco MDS 4/8/16-Gbps Fibre Channel SW SFP+, LC

Short wavelength

DS-SFP-FC16G-LW Cisco MDS 4/8/16-Gbps Fibre Channel LW SFP+, LC

Long wavelength

DS-SFP-FC8G-SW Cisco MDS 2/4/8-Gbps Fibre Channel SW SFP+, LC

Short wavelength

DS-SFP-FC8G-LW Cisco MDS 2/4/8-Gbps Fibre Channel LW SFP+, LC

Long wavelength

DS-SFP-FC8G-ER Cisco MDS 2/4/8-Gbps Fibre Channel Extended Reach SFP+, LC

Extended Reach

DS-CWDM8Gxxxx Cisco MDS 2/4/8-Gbps CWDM Long Distance SFP, LC

Long Distance

1-56Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 63: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Technical Specifications SFP Transceiver Specifications

Table 1-6 Cisco 16-Gbps Fibre Channel SFP+ Cabling Specifications

SFP+ Wavelength (nanometers)

Fiber Type Core Size (microns)

Baud Rate (GBd)

Cable Distance

DS-SFP-FC16G-SW

850 MMF 62.5

50.0

50.0

50.0

62.5

50.0

50.0

50.0

62.5

50.0

50.0

50.

14.025

14.025

14.025

14.025

8.5

8.5

8.5

8.5

4.25

4.25

4.25

4.25

15 m (49 ft) (OM1)

35 m (115 ft) (OM2)

100 m (328 ft) (OM3)

125 m (410 ft) (OM4)

21 m (69 ft) (OM1)

50 m (164 ft) (OM2)

150 m (492 ft) (OM3)

190 m (623 ft) (OM4)

70 m (230 ft) (OM1)

150 m (492 ft) (OM2)

380 m (1247 ft) (OM3)

400 m (1312 ft) (OM4)

DS-SFP-FC16G-LW

1310 SMF 9.0

9.0

9.0

14.025

8.5

4.25

10 km (6.2 mi)

10 km (6.2 mi)

10 km (6.2 mi)

1-57Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 64: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Technical Specifications SFP Transceiver Specifications

Environmental Conditions and Power Requirements 16 Gbps

Table 1-7 provides the optical parameters for 16 Gbps.

Table 1-7 Optical Parameters for 16 Gbps

Table 1-8 provides information on operating and storage temperature ranges

General Specifications for Cisco Fibre Channel 8-Gbps SFP+ Transceivers

Table 1-9 summarizes cabling specifications for 8 Gbps.

SFP+ Average Transmit Power (dBm)

Average Receive Power (dBm)

Fiber Loss Budget (dB)

Max Min Max Min 62.5 microns[OM1])

(50.0 microns [OM2])

(50.0 microns [OM3])

DS-SFP-FC16G-SW -1.3 7, 8 0 -10.3 2.08 (4 Gbps)

1.68 (8 Gbps)

1.63 (16 Gbps)

2.08 (4 Gbps)

1.68 (8 Gbps)

1.63 (16 Gbps)

2.88 (4 Gbps)

2.04 (8 Gbps)

1.86 (16 Gbps)

DS-SFP-FC16G-LW 2.0 -5.0 2.0 10 7.8 (4 Gbps)

6.4 (8 Gbps)

6.4 (16 Gbps)

Table 1-8 Operating and Storage Temperature Ranges for 16 Gbps

SFP+ Operating Storage

Max Min Max Min

DS-SFP-FC16G-SW 40°C 0°C 85°C -40°C

DS-SFP-FC16G-LW 40°C 0°C 85°C -40°C

1-58Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 65: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Technical Specifications SFP Transceiver Specifications

Table 1-9 Cisco 8-Gbps Fibre Channel SFP+ Cabling Specifications

SFP+ Wavelength (nanometers)

Fiber Type Core Size (microns)

Baud Rate (GBd)

Cable Distance

DS-SFP-FC8G-SW 850 MMF 62.5

62.5

62.5

50.0 (OM2)

50.0 (OM2)

50.0 (OM2)

50.0 (OM3)

50.0 (OM3)

50.0 (OM3)

50.0 (OM4)

50.0 (OM4)

50.0 (OM4)

2.125

4.250

8.500

2.125

4.250

8.500

2.125

4.250

8.500

2.125

4.250

8.500

150 m (492 ft)

70 m (230 ft)

21 m (69 ft)

300 m (984 ft)

150 m (492 ft)

50 m (164 ft)

500 m (1640 ft)

380 m (1246 ft)

150 m (492 ft)

520 m (1706 ft)

400 m (1312 ft)

190 m (623 ft)

DS-SFP-FC8G-LW 1310 SMF 9.0

9.0

9.0

2.125

4.250

8.500

10 km (6.2 mi)

10 km (6.2 mi)

10 km (6.2 mi)

DS-SFP-FC8G-ER 1550 SMF 9.0

9.0

9.0

2.125

4.250

8.500

40 km (24.85 mi)

40 km (24.85 mi)

40 km (24.85 mi)

1-59Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 66: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Technical Specifications SFP Transceiver Specifications

Environmental Conditions and Power Requirements for 8 Gbps

Table 1-10 provides the optical parameters for 8 Gbps.

Table 1-10 Optical Parameters for 8 Gbps

Table 1-11 provides information on operating and storage temperature ranges for 8 Gbps.

Optical Specifications for Cisco CWDM SFP Transceivers

Table 1-12 provides the optical specifications for CWDM SFP transceivers. CWDM SFP transceivers have an optical link budget of 28 decibels (db).

Note The parameters are specified over temperature and at end of life unless otherwise noted.

SFP+ Average Transmit Power (dBm)

Average Receive Power (dBm)

Fiber Loss Budget (dB)

Max Min Max Min 62.5 microns[OM1])

(50.0 microns [OM2])

(50.0 microns[OM3])

DS-SFP-FC8G-SW -1.3 -10 (2 Gbps)

-9 (4 Gbps)

-8.2 (8 Gbps)

0 — 2.10 (2 Gbps)

1.78 (4 Gbps)

1.58 (8 Gbps)

2.08 (4 Gbps)

1.68 (8 Gbps)

1.63 (16 Gbps)

3.31 (2 Gbps)

2.88 (4 Gbps)

2.04 (8 Gbps

DS-SFP-FC8 G-LW -3 (2 Gbps)

-1 (4 Gbps)

0.5 (8 Gbps)

-11.7 (2 Gbps)

-8.4 (4 Gbps)

-8.4 (8 Gbps

-3 (2 Gbps)

-1 (4 Gbps)

0.5 (8 Gbps)

— -7.8 (2 Gbps)

7.8 (4 Gbps)

6.4 (8 Gbps)

DS-SFP-FC8G-ER 4 -4.7 -1 — 10.9

Table 1-11 Operating and Storage Temperature Ranges for 8 Gbps

SFP+ Operating Storage

Max Min Max Min

DS-SFP-FC16G-SW 40°C 0°C 85°C -40°C

DS-SFP-FC16G-LW 40°C 0°C 85°C -40°C

1-60Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 67: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Technical Specifications

Note When shorter distances of single-mode fiber are used, it might be necessary to insert an inline optical attenuator in the link to avoid overloading the receiver.

Table 1-12 Optical Specifications for Cisco CWDM SFP Transceivers

ParameterSymbol Min. Typical Max. Units Notes

Transmitter central wavelength

λc (x-4) (x+1) (x+7) nm Available center wavelengths:1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610 nm

Wavelength temperature dependence

0.08 0.1 nm/°C

Side-mode suppression ratio

SMSR 30 dB

Transmitter optical output power

Pout 0.0 5.0 dBm Average power coupled into single-mode fiber

Receiver optical input power (BER <10-12 with PRBS 2-7–1)

Pin -28.0 -7.0 dBm @ 2.12 Gbps, 140°F (60°C) case temp.

Receiver optical input wavelength

λin 1450 1620 Nm

Transmitter extinction ratio

OMI 9 dB

Dispersion penalty at 60 km

2 dB

Dispersion penalty at 100 km

2 db @ 1.25 Gbps

3 dB @ 2.12 Gbps

1-61Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 68: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Technical Specifications

1-62Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 69: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Cisco MDS 9148S

OL-20185-01

C H A P T E R 1

Cable and Port Specifications

This appendix includes the cables and connectors used with the Cisco MDS 9148S Multilayer Fabric Switch, and it includes the following sections:

• Cables and Adapters, page 1-63

• Console Port, page 1-64

• MGMT 10/100 Ethernet Port, page 1-66

• Supported Power Cords and Plugs, page 1-67

Caution We strongly recommend that power cable runs and other potential noise sources be located as far away as practical from network cabling that terminates on Cisco equipment. In situations where long parallel cable runs exist but cannot be separated by at least 3.3 ft. (1 m), we recommend that you shield these potential noise sources. To avoid interference, the source should be shielded by housing it in a grounded metallic conduit.

Cables and Adapters The Cisco MDS 9148S Switch accessory kit includes the following:

• RJ-45 to RJ-45 rollover cable

• RJ-45 to DB-9 female DTE adapter (labeled “Terminal”)

• RJ-45 to DB-25 female DTE adapter (labeled “Terminal”)

• RJ-45 to DB-25 male DCE adapter (labeled “Modem”)

Note Additional cables and adapters can be ordered from your customer service representative.

Note If you purchased this product through a Cisco reseller, contact the reseller directly for technical support. If you purchased this product directly from Cisco, contact Cisco Technical Support at this URL: http://www.cisco.com/cisco/web/support/index.html.

1-63 Multilayer Switch Hardware Installation Guide

Page 70: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Cable and Port Specifications Console Port

Console PortThe console port is an asynchronous RS-232 serial port with an RJ-45 connector. You can use the RJ-45 to RJ-45 rollover cable and the RJ-45 to DB-9 female adapter or the RJ-45 to DB-25 female DTE adapter (depending on your computer serial port) to connect the console port to a computer running terminal emulation software.

Console Port Pinouts

Table 1-1 lists the pinouts for the console port on the Cisco MDS 9148S Switch.

Connecting the Console Port to a Computer Using the DB-25 Adapter

You can use the RJ-45 to RJ-45 rollover cable and RJ-45 to DB-25 female DTE adapter (labeled “Terminal”) to connect the console port to a computer running terminal emulation software. Table 1-2 lists the pinouts for the console port, the RJ-45 to RJ-45 rollover cable, and the RJ-45 to DB-25 female DTE adapter.

Table 1-1 Console Port Pinouts

Pin Signal

11

1. Pin 1 is connected internally to pin 8.

RTS

2 DTR

3 TxD

4 GND

5 GND

6 RxD

7 DSR

8 CTS

Table 1-2 Port Mode Signaling and Pinouts with DB-25 Adapter

Console Port RJ-45 to RJ-45 Rollover Cable

RJ-45 to DB-25 Terminal Adapter

ConsoleDevice

Signal RJ-45 Pin RJ-45 Pin DB-25 Pin Signal

RTS 1 8 5 CTS

DTR 2 7 6 DSR

TxD 3 6 3 RxD

GND 4 5 7 GND

GND 5 4 7 GND

RxD 6 3 2 TxD

1-64Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 71: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Cable and Port Specifications Console Port

Connecting the Console Port to a Computer Using the DB-9 Adapter

You can use the RJ-45 to RJ-45 rollover cable and RJ-45 to DB-9 female DTE adapter (labeled “Terminal”) to connect the console port to a computer running terminal emulation software. Table 1-3 lists the pinouts for the console port, the RJ-45 to RJ-45 rollover cable, and the RJ-45 to DB-9 female DTE adapter.

DSR 7 2 20 DTR

CTS 8 1 4 RTS

Table 1-2 Port Mode Signaling and Pinouts with DB-25 Adapter (continued)

Console Port RJ-45 to RJ-45 Rollover Cable

RJ-45 to DB-25 Terminal Adapter

ConsoleDevice

Signal RJ-45 Pin RJ-45 Pin DB-25 Pin Signal

Table 1-3 Port Mode Signaling and Pinouts with DB-9 Adapter

Console Port RJ-45 to RJ-45 Rollover Cable

RJ-45 to DB-9 Terminal Adapter

ConsoleDevice

Signal RJ-45 Pins RJ-45 Pin DB-9 Pin Signal

RTS 1 8 8 CTS

DTR 2 7 6 DSR

TxD 3 6 2 RxD

GND 4 5 5 GND

GND 5 4 5 GND

RxD 6 3 3 TxD

DSR 7 2 4 DTR

CTS 8 1 7 RTS

1-65Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 72: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Cable and Port Specifications MGMT 10/100 Ethernet Port

MGMT 10/100 Ethernet PortUse a modular, RJ-45, straight-through UTP cable to connect the 10/100 management Ethernet port to external hubs and switches. To connect to a router, use a crossover cable. (See Figure 1-1.)

Figure 1-1 RJ-45 Interface Cable Connector

Table 1-4 lists the connector pinouts and signal names for a 10/100BASE-T management port (MDI) cable.

Figure 1-2 shows a schematic of the 10/100BASE-T cable.

Figure 1-2 Twisted-Pair 10/100BASE-T Cable Schematic

1 Pin 1 2 Pin 8

9497

11 2

RJ-45 (both ends)

Table 1-4 10/100BASE-T Management Port Cable Pinout

Pin Signal

1 TD+

2 TD-

3 RD+

6 RD–

4 Not used

5 Not used

7 Not used

8 Not used

1 RD+

2 RD-

3 TD+

6 TD-

1 RD+

Switch Switch

2 RD-

3 TD+

6 TD-

4 NC

5 NC

7 NC

8 NC

4 NC

5 NC

7 NC

8 NC 6527

3

1-66Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 73: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Cable and Port Specifications Supported Power Cords and Plugs

Supported Power Cords and PlugsA separate power cord is provided for each power supply. Standard power cords or jumper power cords are available for connection to a power distribution unit having IEC 60320 C13 outlet receptacles. The jumper power cords, for use in cabinets, are available as an option instead of the standard power cords.

Power Cords

The standard power cords have an IEC C15 connector on the end that plugs into the switch. The optional jumper power cords have an IEC C15 connector on the end that plugs into the switch, and an IEC C14 connector on the end that plugs into an IEC C13 outlet receptacle.

Note Only the standard power cords or jumper power cords provided with the switch are supported.

Note If you do not order the optional power cord with the system, you are responsible for selecting the appropriate power cord for the product. Using a non-compatible power cord with this product may result in electrical safety hazard. Orders delivered to Argentina, Brazil, and Japan must have the appropriate power cord ordered with the system.

Figure 1-3 shows the supported plugs for the Cisco MDS 9100 Series power supplies.

1-67Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 74: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Cable and Port Specifications Supported Power Cords and Plugs

Figure 1-3 300-W Power Supply Plugs

Jumper Power Cord

Figure 1-4 shows the C14 and C15 connectors on the optional jumper power cord for the Cisco MDS 9148S Switch. The C15 connector connects into the C14 inlet on the Cisco MDS 9148S Switch power supply, while the C14 connector connects into the C13 receptacle of a power distribution unit for a cabinet.

1 Argentina,IRAM 2073 plug (10 A)

5 Italy1/3G plug, CEI 23-16 (10 A)

2 North AmericaNEMA 5-15P plug (15 A)

6 United KingdomBS89/13, BS 1363/A (13 A; replaceable fuse)

3 Australia, New ZealandSAA/3 plug, AS/NZS 3112-1993 (10 A)

7 South Africa EL 208, SABS 164-1 (10 A)

4 EuropeVIIG Plug, CEE (7) VII (16 A)

8 Switzerland12G SEV 1011 (10 A)

9927

1

1 2

3 4

5 6

87

1-68Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 75: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Cable and Port Specifications Supported Power Cords and Plugs

Figure 1-4 Connectors on Jumper Power Cord for Cisco MDS 9148S Switch

1131

65

C14

C15

1-69Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 76: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Cable and Port Specifications Supported Power Cords and Plugs

1-70Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 77: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Cisco MDS 9148S

OL-20185-01

C H A P T E R 1

Site Planning and Maintenance Records

This appendix includes a site planning checklist and maintenance records to use when installing the Cisco MDS 9148S Multilayer Fabric Switch, and it includes the following sections:

• Site Preparation Checklist, page 1-71

• Contact and Site Information, page 1-73

• Chassis and Network Information, page 1-74

Note For information about how to query the switch for configuration information, see the Cisco NX-OS Fundamentals Configuration Guide.

Site Preparation ChecklistPlanning the location and layout of your equipment rack or wiring closet is essential for successful switch operation, ventilation, and accessibility. Table 1-1 lists the site planning tasks that we recommend completing before installing the Cisco MDS 9148S Switch.

Consider heat dissipation when sizing the air-conditioning requirements for an installation. See Table 1-1 for environmental requirements and Table 1-4 for power and heat ratings.

1-71 Multilayer Switch Hardware Installation Guide

Page 78: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Site Planning and Maintenance Records Site Preparation Checklist

Table 1-1 Site Planning Checklist

Task No. Planning Activity Verified By Time Date

1 Space evaluation:

• Space and layout

• Floor covering

• Impact and vibration

• Lighting

• Maintenance access

2 Environmental evaluation:

• Ambient temperature

• Humidity

• Altitude

• Atmospheric contamination

• Air flow

3 Power evaluation:

• Input power type

• Power receptacles1

• Receptacle proximity to the equipment

• Dedicated circuit for power supply

• Dedicated (separate) circuits for redundant power supplies

• UPS2 for power failures

1. Verify that the power supply installed in the chassis has a dedicated AC source circuit.

2. UPS = uninterruptible power supply.

4 Grounding evaluation:

• Circuit breaker size

• CO ground (AC- powered systems)

5 Cable and interface equipment evaluation:

• Cable type

• Connector type

• Cable distance limitations

• Interface equipment (transceivers)

6 Electromagnetic interference (EMI) evaluation:

• Distance limitations for signaling

• Site wiring

• RFI3 levels

3. RFI = radio frequency interference.

1-72Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 79: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Site Planning and Maintenance Records Contact and Site Information

Contact and Site InformationUse the following worksheet to record contact and site information.

Table 1-2 Contact and Site Information

Contact person

Contact phone

Contact E-Mail

Building/site name

Data center location

Floor location

Address (line 1)

Address (line 2)

City

State

Zip code

Country

1-73Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01

Page 80: Cisco MDS 9148S Multilayer Switch Hardware …€¦ · iii Cisco MDS 9148S Multilayer Switch Hardware Installation Guide OL-20185-01 CONTENTS Preface Audience ix Organization ix Document

Chapter 1 Site Planning and Maintenance Records Chassis and Network Information

Chassis and Network InformationUse the following worksheets to record chassis and network information.

Contract Number ______________________________________________________________

Chassis Serial Number ______________________________________________________________

Product Number ______________________________________________________________

Table 1-3 Network-Related Information

Switch IP address

Switch IP netmask

Host name

Domain name

IP broadcast address

Gateway/router address

DNS address

Modem telephone number

1-74Cisco MDS 9148S Multilayer Switch Hardware Installation Guide

OL-20185-01