City and County of San Francisco San Francisco Fire Department Fire Apparatus Committee
Technical Specifications for: Emergency Fuel Dispensing Vehicle Attachment C, revised 04/06/12
CITY AND COUNTY OF SAN FRANCISCO # FC121R SAN FRANCISCO FIRE DEPARTMENT VEH # 4500072
RQFC12000042
ITSF12000686/CD ATTACHMENT C
EQUIPMENT SPECIFICATIONS FOR SUPPLIED 2850-1000 GALLON CAPACITY DIESEL-GASOLINE ALUMINUM TANKER
TO BE REMOUNTED ON A NEW 3 AXLES, 60,000 GVWR CAB AND CHASSIS
LAST REVISION 4/6/2012
______________________________________________________________________
Page 1 of 26
SECTION 1 - GENERAL EQUIPMENT SPECIFICATIONS: 1
2
SPECIFICATION OUTLINE: 3
The following specifications are for an existing City owned Aluminum 2850-1000 gallon 4
Diesel-Gasoline tanker to be transferred and mounted on an new 3-axle, 60,000 GVWR 5
truck chassis are divided into three complete sections. The first section outlines the 6
overall specification requirements. The second details the chassis portion of the new 7
truck the city supplied tank shall be transferred to and mounted on. The third section 8
refers mostly to the City supplied tanker that is to be mounted onto the truck chassis. 9
The Fuel Tanker shall be delivered complete with all equipment and accessories 10
necessary for safe and efficient operation, ready for immediate job site operation within 11
the City of San Francisco. The unit shall comply with the manufacturer’s current model 12
truck chassis, with additions and deletions as contained herein. 13
14
INTENT OF SPECIFICATIONS: 15
16
It is the intent of these specifications to cover the furnishing and delivery to the San 17
Francisco Fire Department of a complete apparatus equipped as hereafter specified. 18
These specifications cover minimum requirements as to the type of construction and 19
test to which the apparatus “Must” conform. 20
21
The apparatus specified herein must be capable of meeting or exceeding the 22
requirements set forth in the San Francisco Fire Department road acceptance test. 23
SFFD specifications supersede all items in the bid package. 24
25
The apparatus and components shall conform to these specifications in every respect 26
along with the related latest edition of all Federal DOT and State of California 27
standards and requirements pertaining to a vehicle of this type. SFFD road test must 28
be met. 29
30
DEFINITION OF TERMS: 31
32
San Francisco Fire Department hereafter shall be referred to as SFFD. 33
Bureau of Equipment hereafter shall be referred to as BOE. 34
City and County of San Francisco hereinafter shall be referred to as the “City “or 35
“CCSF”. 36
CITY AND COUNTY OF SAN FRANCISCO # FC121R SAN FRANCISCO FIRE DEPARTMENT VEH # 4500072
RQFC12000042 ITSF12000686/CD
ATTACHMENT C EQUIPMENT SPECIFICATIONS FOR
SUPPLIED 2850-1000 GALLON CAPACITY DIESEL-GASOLINE ALUMINUM TANKER
TO BE REMOUNTED ON A NEW 3 AXLES, 60,000 GVWR CAB AND CHASSIS
LAST REVISION 4/6/2012
______________________________________________________________________
Page 2 of 26
IMPORTANT: PRE-BID CONFERENCE 37
Because of the variances in the truck chassis that may be bid, it may be necessary to 38
vary the bed dimensions and design to some degree. 39
40
A Pre-bid Conference will be held as follows: 41
42
DATE: Thursday April 5, 2012 43
TIME: 09:00 AM 44
PLACE: City & County of San Francisco 45
Central Shops 46
1800 Jerrold Avenue 47
San Francisco, CA 48
49
Though not mandatory, attendance at the conference is strongly urged for all 50
prospective bidders on this contract. 51
52
It is requested that bidder’s questions concerning this Contract Proposal be 53
submitted by mail or Fax at least 72 hours prior to the date and time of the Pre-bid 54
Conference and directed to: 55 56 57
Daisy Aguallo Senior Purchaser Phone: (415) 554-6714 58
Department OCA Purchasing FAX: (415) 554-6717 59
Purchasing Division 60
1 Dr. Carlton B. Goodlett Place 61
San Francisco, CA 94102 62
63
Please reference Bid Proposal No. ITSF12000686/CD 64
65
The Pre-bid Conference will begin at the time specified, and company 66
representatives are urged to arrive on time. Topics already covered will not be 67
repeated for the benefit of late arrivals. Failure to attend the Pre-bid Conference 68
shall not excuse the successful bidder from any obligations of the contract. Any 69
change or addition to the requirements contained in this Contract Proposal as a 70
result of the Pre-Bid Conference will be executed by written Bid Addendum. 71
72
SERVICE REQUIREMENTS: 73
CITY AND COUNTY OF SAN FRANCISCO # FC121R SAN FRANCISCO FIRE DEPARTMENT VEH # 4500072
RQFC12000042 ITSF12000686/CD
ATTACHMENT C EQUIPMENT SPECIFICATIONS FOR
SUPPLIED 2850-1000 GALLON CAPACITY DIESEL-GASOLINE ALUMINUM TANKER
TO BE REMOUNTED ON A NEW 3 AXLES, 60,000 GVWR CAB AND CHASSIS
LAST REVISION 4/6/2012
______________________________________________________________________
Page 3 of 26
74
Bidders shall have an authorized service facility within 100 miles of the City and County 75
of San Francisco. That service facility shall employ ASE and EVT certified technicians. 76
A positive guarantee shall accompany all bids stating that the manufacturer will have 77
parts available on a 24-hour basis and is within 1-hour proximity to a major airport. 78
79
PROPOSAL DRAWING (To be submitted with bid): 80
81
Each bidder should submit a drawing of the apparatus as proposed with their bid. The 82
drawing should include left side view, rear view, front view, and right side view. The 83
drawing should also show inside compartments. In addition, drawings of the 84
compartment door construction and body sub-frame are to be provided. A typical wiring 85
diagram similar to that proposed should also be submitted with the bid for review by the 86
SFFD. 87
88
APPROVAL DRAWING (To be submitted after award of contract): 89
90
The successful bidder shall submit a detailed-scaled drawing with 30 calendar days of 91
bid award for SFFD approval prior to construction of the apparatus. The drawing shall 92
include left, right, front, and rear side views and “all” apparatus compartment layouts. 93
The drawings supplied must be done specifically for the SFFD. Any drawings that are 94
“Generic” are not acceptable and will be considered non-compliant. (NO EXCEPTIONS 95
WILL BE ALLOWED). 96
97
The blueprints shall be completed by the Manufacturer and must be exact to the SFFD 98
specifications. 99
100
Successful bidder shall not start construction until one (1) set of complete plans has 101
been approved by the SFFD. 102
103
The bidder’s engineering drawings shall be produced on a computer-aided-design 104
(CAD) equipment at assure critical dimensions and detail. The blueprints shall be on 105
“D” size paper (standard) 36” X 24” in size. Scale shall be ½” = 1’0”. 106
107
DELIVERY AND TRAINING: 108
109
CITY AND COUNTY OF SAN FRANCISCO # FC121R SAN FRANCISCO FIRE DEPARTMENT VEH # 4500072
RQFC12000042 ITSF12000686/CD
ATTACHMENT C EQUIPMENT SPECIFICATIONS FOR
SUPPLIED 2850-1000 GALLON CAPACITY DIESEL-GASOLINE ALUMINUM TANKER
TO BE REMOUNTED ON A NEW 3 AXLES, 60,000 GVWR CAB AND CHASSIS
LAST REVISION 4/6/2012
______________________________________________________________________
Page 4 of 26
The successful bidder shall, at their expense, deliver the apparatus to the SFFD, City 110
and County of San Francisco, Central Shops, 1800 Jerrold Avenue, San Francisco, 111
California 94124. Apparatus shall be completely cleaned and detailed in showroom 112
condition before delivery. A factory trained and authorized delivery instructor shall then 113
remain with the apparatus for three (3) days to train the SFFD personnel in the 114
operation and preventive maintenance of the apparatus. Limited “Familiarization” 115
Programs will not be acceptable. 116
117
PRE-CONSTRUCTION (ENGINEERING): 118
119
Within 30 days of bid award, the manufacturer shall be required to meet with (2) 120
representatives from the SFFD to discuss the technical specifications before the fuel 121
unit construction begins. This meeting will include confirming the exterior and interior 122
dimensions and exact locations of equipment. Meeting is to be held at the mutual 123
agreement upon place, preferably at the unit build facility. All travel expenses will be 124
arranged and paid by the successful bidder. 125
126
INSPECTION TRIPS (include in specs if applicable): 127
128
Bid price should include airfare (if over 125 miles from San Francisco), meals and 129
lodging for 2 factory inspection trips for 2 City representatives. The inspection trips shall 130
be scheduled at times mutually agreed upon between the awarded bidder and the City 131
representatives and should be for a minimum 2 days. Meals and lodging rate shall 132
comply with the current Federal Rates for the Continental U.S.A. The rates are 133
available from the following website: 134
135
www.gsa.gov/perdiem 136
137
The first inspection trip, known as the “pre-paint” or mid-inspection will be arranged at a 138
time when the vehicle is assembled with major components installed and before final 139
paint work is begun. If the inspection discloses any deviation from the specifications, 140
the discrepancies, if minor can be corrected while City inspectors remain at the plant. 141
142
The second inspection trip will be the final factory inspection of the completed vehicle 143
completely finished and ready for delivery. Workmanship and finish will be inspected 144
and the vehicle will be road tested and equipment operated before final delivery. If the 145
inspection discloses any deviation from the specifications, the discrepancies, if minor 146
CITY AND COUNTY OF SAN FRANCISCO # FC121R SAN FRANCISCO FIRE DEPARTMENT VEH # 4500072
RQFC12000042 ITSF12000686/CD
ATTACHMENT C EQUIPMENT SPECIFICATIONS FOR
SUPPLIED 2850-1000 GALLON CAPACITY DIESEL-GASOLINE ALUMINUM TANKER
TO BE REMOUNTED ON A NEW 3 AXLES, 60,000 GVWR CAB AND CHASSIS
LAST REVISION 4/6/2012
______________________________________________________________________
Page 5 of 26
can be corrected while City inspectors remain at the plant. If the problem is not readily 147
correctable, the inspectors can return for inspection at a mutually agreed time, at the 148
expense of the awarded bidder. 149
150
BIDDER’S COMPLIANCE AND EXCEPTIONS: 151
All exceptions shall be stated no matter how seemingly minor. Bidders shall 152
indicate compliance with each section and line item specifications as required, in 153
the line spaces provided by marking with a “Y” for yes. If the bidder is offering 154
an alternate of equal or superior status to the line item specification, bidder will 155
indicate by marking with an “E” for exception on each line item. The bidder must 156
then reference each item exception and explain the exception taken and the 157
proposed alternate on Attachment D, Bid Exception Sheets. 158
159
**Bids which do not include confirmation of each section and line item as 160
required, will be deemed to take exception to such bid requirements, which may 161
result in the bid being deemed non-responsive. If exceptions are taken, 162
Attachment D, Bid Exception Sheets must be returned with the submitted bids. 163
164
IMPORTANT: If a single vendor is submitting multiple bids, the vendor shall 165
submit a completed set of specs for each individual bid. Multiple bids that are 166
submitted as one bid package will not be acceptable. 167
168
SECTION TWO - TECHNICAL REQUIREMENTS: 169
170
VEHICLE OPERATION, PERFORMANCE, AND PHYSICAL CHARACTERISTICS 171
172
The following is a description of the cab and chassis that will meet the requirements of 173
this specification. 174
175
TECHNICAL REQUIREMENTS CAB & CHASSIS: 176
177
_____Vehicle shall be 2012 or newer (current) International 7500 SBA 6x4 with 226.0” 178
wheelbase, 158.90” CA, and 96.00” AF or approved equal. 179
_____ENGINE, DIESEL {MaxxForce 10} EPA 10, 350 HP @ 2000 RPM, 1150 lb-ft 180
Torque @ 1200 RPM, 2200 RPM Governed Speed or approved equal. 181
_____FEDERAL EMISSIONS for 2010 or newer 182
CITY AND COUNTY OF SAN FRANCISCO # FC121R SAN FRANCISCO FIRE DEPARTMENT VEH # 4500072
RQFC12000042 ITSF12000686/CD
ATTACHMENT C EQUIPMENT SPECIFICATIONS FOR
SUPPLIED 2850-1000 GALLON CAPACITY DIESEL-GASOLINE ALUMINUM TANKER
TO BE REMOUNTED ON A NEW 3 AXLES, 60,000 GVWR CAB AND CHASSIS
LAST REVISION 4/6/2012
______________________________________________________________________
Page 6 of 26
_____Engine shall comply with 2010 or current EPA/CARB emission regulations for 183
engine and vehicle type. 184
_____CARB required five minute engine idle shutdown feature shall be disabled. 185
(Emergency vehicles are exempt from Title 13, CCR, Sections 2485 and 186
1956.8 regulations). 187
_____FRAME RAILS Heat Treated Alloy Steel (120,000 PSI Yield); 10.866" x 3.622" x 188
0.433" (276.0mm x 92.0mm x 11.1mm); 456.0" (11582mm) Maximum OAL 189
_____TOW HOOK, FRONT (2) Frame Mounted 190
_____BUMPER, FRONT Full Width, Aerodynamic, Chrome Plated Steel; 0.189" 191
_____Material Thickness -WHEELBASE RANGE 221" (560cm) Through and Including 192
262" (665cm) 193
_____FRAME ADDITION, FRONT 1" Integral; Increases BBC, BA and OAL Vehicle 194
Dimensions By 1" 195
_____AXLE, FRONT NON-DRIVING {Meritor MFS-20} Wide Track, I-Beam Type, 196
20,000-lb Capacity 197
_____SUSPENSION, FRONT, SPRING Parabolic, Taper Leaf; 20,000-lb Capacity; 198
With Shock Absorbers 199
_____AXLE, REAR, TANDEM {Meritor MT-40-14X-4DCR-P} Single Reduction, 200
0.433"(11mm) Wall Housing Thickness, 40,000-lb Capacity, R Wheel Ends, Lube 201
Pump, With Driver Controlled Locking Differential in Forward Rear and Rear Axle 202
Gear Ratio: 5.29 203
_____SUSPENSION, REAR, AIR, TANDEM {International} Ride Optimized Suspension 204
IROS) Heavy Duty; 52" Axle Spacing; 40,000-lb Capacity, 9.25" Ride Height, 205
Includes (Heavy Duty Spring Hangers, Cross members and Fasteners, With 206
Shock Absorbers 207
_____BRAKE SYSTEM, AIR Dual System for Straight Truck Applications 208
_____AIR BRAKE ABS {Bendix Antilock Brake System} Full Vehicle Wheel Control 209
System (4-Channel) 210
_____BRAKES, FRONT, AIR CAM 16.5" x 6” 211
_____BRAKE CHAMBERS; FRONT AXLE {Haldex} 24 SqIn 212
_____BRAKES, REAR, AIR CAM S-Cam; 16.5" x 7.0" 213
_____BRAKE CHAMBERS, REAR AXLE {Haldex GC3030LHDHO} 30/30 Spring Brake 214
_____AIR COMPRESSOR {Bendix Tu-Flo 550} 13.2 CFM Capacity 215
_____AIR TANK LOCATION (2) Mounted Outside Right Rail, Under Cab, On Step 216
Mounting Brackets 217
_____ DRAIN VALVE {Berg} Manual; With Pull Chain accessible from side 218
of vehicle, for Air Tank draining 219
CITY AND COUNTY OF SAN FRANCISCO # FC121R SAN FRANCISCO FIRE DEPARTMENT VEH # 4500072
RQFC12000042 ITSF12000686/CD
ATTACHMENT C EQUIPMENT SPECIFICATIONS FOR
SUPPLIED 2850-1000 GALLON CAPACITY DIESEL-GASOLINE ALUMINUM TANKER
TO BE REMOUNTED ON A NEW 3 AXLES, 60,000 GVWR CAB AND CHASSIS
LAST REVISION 4/6/2012
______________________________________________________________________
Page 7 of 26
_____AIR DRYER {Bendix AD-IS EP} Spin-on With Heater 220
_____STEERING COLUMN Tilting 221
_____STEERING WHEEL 2-Spoke, 18" Diam., Black 222
_____STEERING GEAR (2) {Sheppard M-100/M-80} Dual Power 223
_____EXHAUST SYSTEM Single, Horizontal, after treatment Device Frame Mounted 224
outside Right Rail under Cab; Includes Vertical Tail Pipe and Guard 225
_____ENGINE COMPRESSION BRAKE for MaxxForce I6 Engines; Electronically 226
Activated 227
_____TAIL PIPE (1) Turn back Type, Bright, for Single Exhaust 228
_____MUFFLER/TAIL PIPE GUARD (1) Bright Stainless Steel 229
_____SWITCH, FOR EXHAUST 2 Position, Lighted & Latching, ON/OFF Type, 230
Mounted in IP, Inhibits Diesel Particulate Filter Regeneration as Long as Switch 231
is in ON Position 232
_____ELECTRICAL SYSTEM 12-Volt, Standard Equipment 233
_____CIGAR LIGHTER Includes Ash Cup 234
_____HORN, ELECTRIC (2) 235
_____POWER SOURCE Cigar Type Receptacle without Plug and Cord 236
_____ALTERNATOR {Leece-Neville A0014962PASE} Brush Type; 12 Volt 320 Amp. 237
Capacity, Pad Mounted 238
_____BODY BUILDER WIRING Back of Standard Cab at Left Frame or Under 239
Extended or Crew Cab at Left Frame; Includes Sealed Connectors for 240
Tail/Amber Turn/Marker/ Backup/Accessory Power/Ground and Sealed 241
Connector for Stop/Turn 242
_____BATTERY SYSTEM Maintenance-Free, (2) Group 31S 12-Volt 2380 CCA Total 243
_____RADIO {International} AM/FM Stereo with Weatherband, Clock, Auxiliary Input, 244
Includes Multiple Speakers 245
_____HORN, AIR Black, Single Trumpet, Air Solenoid Operated 246
_____BATTERY BOX Steel, With Aluminum Cover, 2 Battery Capacity, Mounted 247
Curbside under Cab below Frame Mounted Exhaust, Provides Clean CA 248
_____SWITCH, TOGGLE, FOR WORK LIGHT Lighted; on Instrument Panel and Wiring 249
Effects for Customer Furnished Back of Cab Light 250
_____CLEARANCE/MARKER LIGHTS (5) Amber LED Lights, Flush Mounted on Cab 251
_____STARTING MOTOR {Delco Remy 38MT Type 300} 12 Volt; less Thermal Over- 252
Crank Protection 253
_____COURTESY LIGHT (2) Mounted In Front Map Pocket Left and Right Side 254
_____INDICATOR, LOW COOLANT LEVEL with Audible Alarm 255
_____ALARM, PARKING BRAKE Electric Horn Sounds in Repetitive Manner When 256
CITY AND COUNTY OF SAN FRANCISCO # FC121R SAN FRANCISCO FIRE DEPARTMENT VEH # 4500072
RQFC12000042 ITSF12000686/CD
ATTACHMENT C EQUIPMENT SPECIFICATIONS FOR
SUPPLIED 2850-1000 GALLON CAPACITY DIESEL-GASOLINE ALUMINUM TANKER
TO BE REMOUNTED ON A NEW 3 AXLES, 60,000 GVWR CAB AND CHASSIS
LAST REVISION 4/6/2012
______________________________________________________________________
Page 8 of 26
Vehicle Park Brake is "NOT" Set, With Ignition "OFF" and any Door Opened 257
_____CIRCUIT BREAKERS Manual-Reset (Main Panel) SAE Type III with Trip 258
Indicators, Replaces All Fuses Except For 5-Amp Fuses 259
_____FENDER EXTENSIONS Rubber 260
_____GRILLE Stationary, Chrome 261
_____BUG SCREEN Front End; Mounted Behind Grille 262
_____FRONT END Tilting, Fiberglass, With Three Piece Construction; for 2007 & 2010 263
Emissions 264
_____PAINT SCHEMATIC, PT-1 Single Color, RED, Design 100 265
_____PAINT TYPE Base Coat/Clear Coat, 1-2 Tone 266
_____CLUTCH Omit Item (Clutch & Control) 267
_____OIL FILTER, ENGINE {Hudgins Model 960 Spinner} 268
_____BLOCK HEATER, ENGINE {Phillips} 120 Volt/1250 Watt 269
_____FAN DRIVE {Horton Drive master Polar Extreme} Direct Drive Type, Two Speed, 270
With Residual Torque Device for Disengaged Fan Speed 271
_____RADIATOR Aluminum, Front to Back Cross Flow, Series System; 1663 SqIn 272
Core and 885 Sq. In. Charge Air Cooler and 470 SqIn Low Temperature 273
Radiator Down Flow. 274
_____AIR CLEANER Single Element 275
_____THROTTLE, HAND CONTROL Engine Speed Control for PTO; Electronic, 276
Stationary Pre-Set, Two Speed Settings; Mounted on Steering Wheel 277
_____ENGINE CONTROL, REMOTE MOUNTED Provision for; Includes Wiring for 278
Body Builder Installation of PTO Controls; With Ignition Switch Control for Maxx 279
Force post 2007 Emissions Electronic Engines 280
_____TRANSMISSION, AUTOMATIC {Allison 3000_RDS_P} 4th Generation Controls; 281
Close Ratio, 6-Speed, With Double Overdrive; On/Off Hwy; Includes Oil Level 282
Sensor, With dual PTO Provision, with Retarder, With 80,000-lb GVW & GCW 283
Max. 284
_____OIL COOLER, AUTO TRANSMISSION {Modine} Water to Oil, for Allison or 285
_____CEEMAT Transmission 286
_____TRANSMISSION SHIFT CONTROL {Allison} Push-Button Type; for Allison 3000 287
& 4000 Series Transmission 288
_____ALLISON SPARE INPUT/OUTPUT for Rugged Duty Series (RDS); General 289
Purpose Trucks 290
_____SHIFT CONTROL PARAMETERS Allison Performance Programming in Primary 291
and Allison Economy Programming in Secondary 292
_____FUEL TANK Top Draw; D Style, Non Polished Aluminum, 19" Deep, 70 U.S. Gal., 293
CITY AND COUNTY OF SAN FRANCISCO # FC121R SAN FRANCISCO FIRE DEPARTMENT VEH # 4500072
RQFC12000042 ITSF12000686/CD
ATTACHMENT C EQUIPMENT SPECIFICATIONS FOR
SUPPLIED 2850-1000 GALLON CAPACITY DIESEL-GASOLINE ALUMINUM TANKER
TO BE REMOUNTED ON A NEW 3 AXLES, 60,000 GVWR CAB AND CHASSIS
LAST REVISION 4/6/2012
______________________________________________________________________
Page 9 of 26
265 L Capacity, With Quick Connect Outlet, Mounted Right Side, Under Cab 294
_____CAB Conventional, rear window delete 295
_____GAUGE CLUSTER English with English Electronic Speedometer 296
_____GAUGE, TEMPERATURE, AMBIENT Includes Compass Readout and Wiring 297
and Sensor with Display Unit Mounted in Cluster 298
_____GAUGE, OIL TEMP, ALLISON TRANS. 299
_____GAUGE, AIR CLEANER RESTRICTION {Filter-Minder} With Black Bezel 300
Mounted in Instrument Panel 301
_____IP CLUSTER DISPLAY On Board Diagnostics Display of Fault Codes in Gauge 302
Cluster 303
_____SEAT, DRIVER {National 2000} Air Suspension, High Back With Integral 304
Headrest, Vinyl, Isolator, 1 Chamber Lumbar, With 2 Position Front Cushion 305
_____SEAT, PASSENGER {Gra-Mag} Non Suspension, High Back, Fixed Back, 306
Integral Headrest, Vinyl 307
_____MIRRORS (2) {Lang Mark} Styled; Rectangular, 7.09" x 15.75" & Integral Convex 308
Both Side, 102" Inside Spacing, Breakaway Type, Heated Heads Thermostatic 309
Controlled, Bright Finish Heads and Brackets 310
_____GRAB HANDLE Chrome; Towel Bar Type With Anti-Slip Rubber Inserts; for Cab 311
Entry Mounted Left Side Only on outside of "B" Pillar 312
_____ARM REST, RIGHT, DRIVER SEAT 313
_____AIR CONDITIONER {Blend-Air} With Integral Heater & Defroster 314
_____INSTRUMENT PANEL Center Section, Flat Panel 315
_____HVAC FRESH AIR FILTER 316
_____STORAGE POCKET, Molded Plastic, Full Width; Mounted on passenger door 317
_____CAB INTERIOR TRIM Deluxe 318
_____CAB REAR SUSPENSION Air Bag Type 319
_____WHEELS, FRONT DISC; 22.5" Painted steel, 10-Stud (285.75MM BC) Hub 320
Piloted, Flanged Nut, Metric Mount, 9.00 DC Rims; With Steel Hubs, chrome caps 321
and lug nut covers 322
_____WHEELS, REAR DUAL DISC; 22.5" Steel Outer Wheel, with Steel Inner Wheel; 323
10-Stud (285.75MM BC) Hub Piloted, Flanged Nut, Metric Mount, 8.25 DC Rims, 324
With Steel Hubs and chrome caps and lug nut covers 325
_____(8) TIRE, REAR 11R22.5 HDR1 (CONTINENTAL) 495 rev/mile, load range G, 14 326
ply 327
_____(2) TIRE, FRONT 315/80R22.5 HSU2 (CONTINENTAL) 481 rev/mile, load range 328
L, 20 ply 329
330
CITY AND COUNTY OF SAN FRANCISCO # FC121R SAN FRANCISCO FIRE DEPARTMENT VEH # 4500072
RQFC12000042 ITSF12000686/CD
ATTACHMENT C EQUIPMENT SPECIFICATIONS FOR
SUPPLIED 2850-1000 GALLON CAPACITY DIESEL-GASOLINE ALUMINUM TANKER
TO BE REMOUNTED ON A NEW 3 AXLES, 60,000 GVWR CAB AND CHASSIS
LAST REVISION 4/6/2012
______________________________________________________________________
Page 10 of 26
LOOSE EQUIPMENT: 331
332
The following equipment shall be shipped loose with the vehicle: 333
_____Touch up 334
_____Cord End for Shoreline 20A 335
_____Mounted Spare Tire & Wheel front, painted to match job color 336
_____Mounted Spare Tire & Wheel, rear, painted to match job color 337
_____Four (4) sets of keys 338
_____Four (4) sets of key Fob’s 339
_____Loose equipment to be shipped to SFFD 2501 25th Street, San Francisco 340
CA, 94110 341
342
WARRANTIES: 343
344
_____Engine shall warranty shall be for a minimum period of 5-year/150,000 mile 345
_____Transmission warranty shall be for a minimum period of 5 year/100,000 mile 346
_____Drive train warranty shall be for a minimum period of 2 year/100,000 mile 347
_____Structural components warranty shall be for a minimum period of 2 year/100,000 348
miles. 349
_____Corrosion warranty shall be for a minimum period of 5 year/unlimited mileage 350
_____Safety Restraint warranty shall be for a minimum period of 5-year/50,000 miles 351
352
VENDOR INSTALLED EQUIPMENT: 353
354
ENGINE HIGH IDLE CONTROL: 355
356
_____The vehicle shall be equipped with a high idle control switch on the drivers dash 357
area and shall maintain a speed of 1250 RPM when engaged 358
359
VEHICLE TOP SPEED: 360
361
_____The top speed of the vehicle shall be approximately 68 MPH at governed engine 362
RPM 363
364
PAINTING, COLOR AND MARKERS: 365
366
CITY AND COUNTY OF SAN FRANCISCO # FC121R SAN FRANCISCO FIRE DEPARTMENT VEH # 4500072
RQFC12000042 ITSF12000686/CD
ATTACHMENT C EQUIPMENT SPECIFICATIONS FOR
SUPPLIED 2850-1000 GALLON CAPACITY DIESEL-GASOLINE ALUMINUM TANKER
TO BE REMOUNTED ON A NEW 3 AXLES, 60,000 GVWR CAB AND CHASSIS
LAST REVISION 4/6/2012
______________________________________________________________________
Page 11 of 26
_____All bare metals shall be coated with a corrosive resistant self etching primer. An 367
automotive urethane sealer shall be used as well as an automotive urethane 368
topcoat. The primer, sealer, and topcoat shall be a minimum of three point three 369
mils thick. A small amount of body filler may be used to smooth imperfections in 370
the metal. Colors and markings will be determined by this agency. The vehicle 371
shall meet salt spray resistance and shall be undercoated. Frame and 372
suspension components shall not be undercoated. 373
_____The paint scheme shall be as follows: The paint must match current Red and 374
White of San Francisco Fire Fleet. Photographs of current production trucks will 375
be provided at preconstruction. 376
_____The chassis frame color shall match the exterior RED color of the lower cab 377
_____The wheel rims of all tires shall be painted RED on both sides including the spare. 378
_____A white reflective six inch stripe shall be installed. This is to match current San 379
Francisco Fire Fleet. 380
_____All cab entry and compartment doors shall have 6 inch solid white reflective 381
striping installed on the lower section of the traffic facing sides and edges. 382
_____Provide and install 80 vinyl 3 inch gold leaf letters with drop shadow to 2 doors 383
and rear of vehicle 384
_____All lettering to match current San Francisco Fire Department fleet. 385
_____The vehicle body shall be undercoated prior to delivery to this agency. No frame 386
or suspension components are to be undercoated. 387
_____Provide and install DOT Duo-Flip 13 x 13 stainless steel placard system on 4 388
sides of vehicle. 389
390
SHORELINE BATTERY CONDITIONER: 391
392
_____Utility power shall be furnished with 120 VAC shore power via a 20 amp 393
Super Auto Eject plug (#091-55-20-120), with red cover, shall be located on 394
driver's side step well of vehicle Power box shall be mounted so as to provide 395
easy access to plug below drivers door. 396
_____Kussmaul Auto Charge 1200 with remote display shall be furnished and installed. 397
Location to be determined at pre-construction meeting 398
399
AUXILIARY AIR CONNECTION: 400
401
_____ Auxiliary air connection shall be installed in the street side step well area and be 402
plumbed with a check valve to prevent air from escaping through the male 403
CITY AND COUNTY OF SAN FRANCISCO # FC121R SAN FRANCISCO FIRE DEPARTMENT VEH # 4500072
RQFC12000042 ITSF12000686/CD
ATTACHMENT C EQUIPMENT SPECIFICATIONS FOR
SUPPLIED 2850-1000 GALLON CAPACITY DIESEL-GASOLINE ALUMINUM TANKER
TO BE REMOUNTED ON A NEW 3 AXLES, 60,000 GVWR CAB AND CHASSIS
LAST REVISION 4/6/2012
______________________________________________________________________
Page 12 of 26
tru- flate connector. 404
405
CURB SIDE FUEL FILL and STEP: 406
407
_____Fuel Fill shall be on the curb side of the chassis below the passenger door 408
and have a 0.125 polished Aluminum diamond plate grip tread 3 sided cover. 409
The cover shall be made to incorporate step access to cab. Design to match 410
existing SFFD fleet. Fuel fill shall be labeled “Diesel Only” white with green 411
lettering. The cap shall be tethered to the aluminum fill well. Use of sheet metal 412
screws for assembly is not acceptable. 413
414
BATTERY BOX: 415
416
_____Battery Box shall be wrapped in aluminum diamond plate 417
418
ELECTRICAL CONSOLE, FRONT: 419
420
_____There shall be a dash mounted switch panel centrally located for easy reach of 421
the driver. 422
_____There shall be 2 power sources, 12 VDC, 20A to terminate behind console. 1 423
shall be constant hot, the second is switched hot. 424
425
CONSOLE SWITCHES (CAB): 426
427
_____One Kussmaul sequencer with in gear override labeled “respond” 428
_____Three scene lights left, right and rear. 429
_____Gasoline hose reel 430
_____Diesel hose reel 431
432
Note: The Kussmaul Sequencer shall manage the electrical load of the vehicle. It shall 433
turn on essential loads such as primary warning lights first and then any optional lighting 434
in a programmed sequential order and it shall turn off in the reverse order. The load 435
manager shall not turn off any components when the vehicle is in gear. California law 436
requires one steady burning forward facing red to remain on with all other lights off 437
438
CONSOLE LAMPS with LABELS and CHIME (CAB): 439
440
CITY AND COUNTY OF SAN FRANCISCO # FC121R SAN FRANCISCO FIRE DEPARTMENT VEH # 4500072
RQFC12000042 ITSF12000686/CD
ATTACHMENT C EQUIPMENT SPECIFICATIONS FOR
SUPPLIED 2850-1000 GALLON CAPACITY DIESEL-GASOLINE ALUMINUM TANKER
TO BE REMOUNTED ON A NEW 3 AXLES, 60,000 GVWR CAB AND CHASSIS
LAST REVISION 4/6/2012
______________________________________________________________________
Page 13 of 26
_____One “compartment ajar” audible alarm and lamp shall be activated when an entry 441
or compartment door is opened and the vehicle is placed in gear. 442
443
HOURMETER (CAB): 444
445
_____A Stewart-Warner quartz hour meter shall be installed on the instrument area of 446
the dash or console if not part of the chassis manufacturer package. 447
_____A battery indicator light shall be provided. It will be a green light located in 448
the warning light panel. It shall illuminate when the battery switch is in the "ON" 449
position. The light shall be steady burn to indicate the batteries have been 450
selected. 451
452
BATTERY GROUNDS: 453
454
_____In addition to OEM grounds the following ground circuits shall be added 455
two (2) braided 4 gauge ground straps from the cabinet body to the chassis to 456
reduce RF interference. 457
COMPARTMENTS, CURB SIDE and STREETSIDE: 458
459
Compartment dimensions are approximate pending design and engineering approval. 460
Exact dimensions and location TBD at pre-construction. 461
462
_____Black vinyl self draining interlocking tiles with beveled end caps shall be provided 463
and installed on the floors and shelves of each enclosed compartment. 464
_____All compartments shall have a stainless steel sill protector. It shall be 465
manufactured from 20 gauge stainless steel and cover the bottom door frame 466
protecting it from scratches. 467
_____The door opening dimensions should be a minimum of 30 inches high, 24 inches 468
wide and 24 inches deep. 469
470
Note: The compartment behind the rear tires on left and right sides shall be labeled L-3 471
& R-3 respectively. 472
473
RUB RAILS: 474
475
_____Rub Rails shall be bright finished extruded aluminum of a double channel 476
CITY AND COUNTY OF SAN FRANCISCO # FC121R SAN FRANCISCO FIRE DEPARTMENT VEH # 4500072
RQFC12000042 ITSF12000686/CD
ATTACHMENT C EQUIPMENT SPECIFICATIONS FOR
SUPPLIED 2850-1000 GALLON CAPACITY DIESEL-GASOLINE ALUMINUM TANKER
TO BE REMOUNTED ON A NEW 3 AXLES, 60,000 GVWR CAB AND CHASSIS
LAST REVISION 4/6/2012
______________________________________________________________________
Page 14 of 26
design and 0.125" wall thickness for maximum strength. Rub rails shall be 2.5" 477
high x 0.75" wide and run along the lower edge of body, interrupted only by 478
wheel well opening. These rub rails shall be along the lower edge of the modular 479
body skirt. The rubber insert shall contain a molded pocket and house a white 480
Scotchlite “Diamond” grade reflective insert. 481
482
REAR FENDERS: 483
_____Rubber fenderettes shall be provided around the rear wheel well openings 484
to provide protection from wheel wash. A corrosion inhibitor shall be applied to 485
the mounting holes prior to installation. An aluminum rear fender with scalloped 486
wheel openings shall be installed and painted to match cabinetry. The fender 487
shall be braced and reinforced to sustain the weight of the truck driver without 488
flexing. 489
490
REAR MUD FLAPS: 491
492
_____Rear mud flaps shall be installed just behind the rear tires. Manufacturer logo on 493
mud flaps is not acceptable. Manufacturer logo any other part of the body shall 494
not exceed (2) at 3 “x 5” 495
496
REAR BUMPER: 497
498
_____Rear bumper shall be a welded construction of 4" x 4" x 0.375" steel tubing plate 499
and shall be trimmed by 0.125" bright aluminum grip tread diamond plate. The 500
bumper shall be bolted directly to the chassis frame using high strength Grade 8 501
bolts. Bumper shall be easily removable and replaceable in case of damage. 502
There shall be at least one inch clearance between the bumper assemble and 503
the rear of the body. Bumper shall meet DOT guidelines for fuel tanker service. 504
An approved design will be provided at preconstruction. 505
506
WIRING INSTALLATION: 507
508
_____The wiring shall be permanently color coded to identify wire function. Wires 509
shall be permanently heat ink embossed with both number and function codes. 510
The function code shall be the descriptive name of the circuit served. The 511
number code shall be the exact purpose of that circuit. This number code shall 512
be completely referenced in a detailed wiring schematic provided with the 513
CITY AND COUNTY OF SAN FRANCISCO # FC121R SAN FRANCISCO FIRE DEPARTMENT VEH # 4500072
RQFC12000042 ITSF12000686/CD
ATTACHMENT C EQUIPMENT SPECIFICATIONS FOR
SUPPLIED 2850-1000 GALLON CAPACITY DIESEL-GASOLINE ALUMINUM TANKER
TO BE REMOUNTED ON A NEW 3 AXLES, 60,000 GVWR CAB AND CHASSIS
LAST REVISION 4/6/2012
______________________________________________________________________
Page 15 of 26
vehicle. The function and number code shall be embossed at a minimum of four 514
inch intervals the entire length of the wire terminating into all switch and control 515
panels. The use of multi-conductor cable must be function and color coded and 516
shown on the wiring diagram. 517
518
_____Wiring shall be routed in conduit or high temperature looms with a rating of 519
300 degrees Fahrenheit where necessary to protect it. All added wiring shall be 520
located in accessible, enclosed, and protected locations and kept at least six 521
inches from the exhaust system components. Electrical wiring and components 522
shall not terminate or be routed in the fuel transfer compartment except for the 523
compartment light, and switch plunger. All conduits, looms, and wiring shall be 524
secured to the body or frame with insulated metal cable straps in order to prevent 525
sagging and movement which results in chafing, pinching, snagging or any other 526
damage. All apertures on the vehicle shall be properly grommeted and sealed for 527
passing wiring all items used for protecting or securing the wiring shall be 528
appropriate for the specific application and be standard automotive, aircraft 529
marine or electronic hardware. 530
531
_____Stainless steel panel with rounded sides to house rear stop, turn and backup 532
lamps shall be installed at rear of vehicle below lower radius of West-Mark tank. 533
Design to be provided at pre-construction meeting 534
535
_____Circuit connections shall be made on barrier style terminal blocks utilizing 536
binding post screws for positive mechanical connections. To minimize the 537
potential for wiring shorts and voltage drops all wiring terminals shall be brass, tin 538
plated, annealed, ETP copper with nylon high heat insulation. Serration's, inside 539
the barrel, provide maximum contact and tensile strength after crimping. 540
Connection shall be machine crimped, to UL standards, with a high quality 541
crimping tool that produces crimps for a given size wire and terminal that are 542
precisely alike in appearance and performance. Crimping pressure must be 543
controlled by a ratchet device on the hand tool or a corresponding pre-calibration 544
in the crimping jaws of an automated machine. Crimping pressure can neither 545
over-stress nor under stress the terminal-barrel-machined dies. Therefore, this 546
agency requires a termination that is free of contamination and is extremely 547
resistant to shock and critical environment conditions. 548
549
_____No splices shall be permitted except for connection of "pig-tail" devices. 550
CITY AND COUNTY OF SAN FRANCISCO # FC121R SAN FRANCISCO FIRE DEPARTMENT VEH # 4500072
RQFC12000042 ITSF12000686/CD
ATTACHMENT C EQUIPMENT SPECIFICATIONS FOR
SUPPLIED 2850-1000 GALLON CAPACITY DIESEL-GASOLINE ALUMINUM TANKER
TO BE REMOUNTED ON A NEW 3 AXLES, 60,000 GVWR CAB AND CHASSIS
LAST REVISION 4/6/2012
______________________________________________________________________
Page 16 of 26
Butt splices are permitted for connection of "pig-tail" devices. The use of 551
insulation displacement type connectors, such as scotch locks type fasteners are 552
not acceptable. 553
554
_____ The various wiring installations as supplied with this vehicle shall be of the 555
automotive "harness" design. For ease of identification and future replacement 556
these harnesses shall be engineered and manufactured in the following 557
sections: 558
559
1. Engine compartment harness. 560
2. Drivers console harness. 561
3. Chassis and Compartment rear lighting harness. 562
4. Emergency lighting harness 563
564
_____The primary manufacturer shall not subcontract the construction of these 565
harnesses. 566
567
LIGHTING: 568
ALL LIGHTING SHALL BE LED 569
570
Clearance lamps 571
_____(5) ICC amber clearance lamp, LED, low intensity, front of cab 572
_____(5) ICC red clearance lamp, LED, low intensity, rear, model #19 Trucklite 573
Mount (3) to vertical wall of rear facing tank well 574
575
Stop, Turn, Tail lamps 576
____Add to stainless steel tank lower radius a stainless steel panel with rounded 577
sides to house 4 LED lamp housings, design to be provided at preconstruction 578
579
Whelen LED 600 series lamps 580
_____Stop lamp is red 581
_____Turn lamp is amber with directional arrow 582
_____Back up lamp shall be clear flood pattern 583
_____Warning lamp shall be amber 584
_____Chrome trimmed reflectors shall be installed below lamp housing 585
586
Compartment lamps 587
CITY AND COUNTY OF SAN FRANCISCO # FC121R SAN FRANCISCO FIRE DEPARTMENT VEH # 4500072
RQFC12000042 ITSF12000686/CD
ATTACHMENT C EQUIPMENT SPECIFICATIONS FOR
SUPPLIED 2850-1000 GALLON CAPACITY DIESEL-GASOLINE ALUMINUM TANKER
TO BE REMOUNTED ON A NEW 3 AXLES, 60,000 GVWR CAB AND CHASSIS
LAST REVISION 4/6/2012
______________________________________________________________________
Page 17 of 26
_____Robinson white LED Rope light or approved equal installed both sides on the 588
vertical in all compartments. 589
590
Underbody Lights 591
_____Ten clear round LED underbody work lights shall be installed under the 592
cab and compartment perimeter in compliance with NFPA 1901. These lights 593
shall be strategically placed to illuminate the immediate ground area around the 594
unit. These lights shall activate with the application of the parking brake. 595
Approved locations to be determined at pre-construction. 596
597
Back up Alarm 598
_____Backup Alarm shall be installed and the alarm shall have a sound output level of 599
97dB. 600
601
License Plate lamp 602
_____A Cast Products #C30002 license plate holder shall be installed in the left rear of 603
the cabinet module. It shall include a Trucklite #15205 LED lamp. 604
605
606
SECTION THREE - SUPPLIED TANK TRANSFER 607
608
DESCRIPTION OF BODY TRANSFER: 609
610
_____ Remove existing West-Mark Tank and install on new cab and chassis. Reuse 611
and reconfigure bottom loading manifold, re-plumb piping to go under frame rail 612
and pump supply lines. Remove and replace obsolete internal valves and sumps. 613
614
615
616
_____Remove reels, meters, operators and piping from each compartment and 617
save to reinstall. Reinstall equipment listed above with new airlines, moisture 618
separator, regulator and gauges. Install filter system for diesel and gasoline 619
systems. Plumb pumps to internal valves and then to the city provided meters 620
and hose reels. 621
_____Remove both side hose reels and storage compartment cabinets, recondition and 622
repaint inside and out, and reinstall on new chassis. 623
_____Install two (2) new PTOs and two (2) new Blackmer TXD2 pumps with drivelines. 624
CITY AND COUNTY OF SAN FRANCISCO # FC121R SAN FRANCISCO FIRE DEPARTMENT VEH # 4500072
RQFC12000042 ITSF12000686/CD
ATTACHMENT C EQUIPMENT SPECIFICATIONS FOR
SUPPLIED 2850-1000 GALLON CAPACITY DIESEL-GASOLINE ALUMINUM TANKER
TO BE REMOUNTED ON A NEW 3 AXLES, 60,000 GVWR CAB AND CHASSIS
LAST REVISION 4/6/2012
______________________________________________________________________
Page 18 of 26
_____Gas and Diesel pumps to have easily replaceable spin on type filters installed 625
near outlet hose connections. 626
_____Furnish and install new two compartment scully system complete. Re-wire two (2) 627
internal valve operators and add emergency release shutoff for each. 628
_____Apply non-skid painted surface to top of tank full length. 629
_____Install access ladder and ladder mounting. 630
_____Install new aluminum fenders at rear with mud-flaps. 631
_____Polish aluminum tank to high glass finish. (like new) 632
_____Repair/replace all tanker pump/hose lines/lighting etc to meet fuel tanker build 633
requirements. 634
_____Add pump start studs 635
_____After remount of West-Mark tank to the vendor supplied cab and chassis the 636
existing (old) cab and chassis shall be delivered in a reasonable time frame to 637
Central Shops 1800 Jerrold Ave. San Francisco, CA. 94124. 638
Cost of delivering existing (old) cab and chassis to Central Shops shall be 639
including in this bid. 640
_____Recertification of Fuel tanker unit as per MC 306 or current applicable regulations 641
shall be done before delivery to the City and documentation shall be provided. 642
643
OWNERS MANUALS AND WARRANTIES: 644
645
Shall be provided with vehicle and consists of the following items: 646
647
_____Chassis owner information packet. 648
_____Factory warranty of Chassis. 649
_____Tank install warranty. 650
_____7 Year/75,000 mile limited electrical warranty min. 651
_____2 Year/30,000 mile Conversion Warranty min. 652
_____5 Year Pain Warranty min. 653
_____Main schematic Chassis Manuals complete set. 654
_____Electrical equipment amperage ratings/wiring diagrams. 655
_____Wire coding list. 656
_____Schematics for standard system: (As Built) 657
658
659
CITY AND COUNTY OF SAN FRANCISCO # FC121R SAN FRANCISCO FIRE DEPARTMENT VEH # 4500072
RQFC12000042 ITSF12000686/CD
ATTACHMENT C EQUIPMENT SPECIFICATIONS FOR
SUPPLIED 2850-1000 GALLON CAPACITY DIESEL-GASOLINE ALUMINUM TANKER
TO BE REMOUNTED ON A NEW 3 AXLES, 60,000 GVWR CAB AND CHASSIS
LAST REVISION 4/6/2012
______________________________________________________________________
Page 19 of 26
660 661
662 663
CITY AND COUNTY OF SAN FRANCISCO # FC121R SAN FRANCISCO FIRE DEPARTMENT VEH # 4500072
RQFC12000042 ITSF12000686/CD
ATTACHMENT C EQUIPMENT SPECIFICATIONS FOR
SUPPLIED 2850-1000 GALLON CAPACITY DIESEL-GASOLINE ALUMINUM TANKER
TO BE REMOUNTED ON A NEW 3 AXLES, 60,000 GVWR CAB AND CHASSIS
LAST REVISION 4/6/2012
______________________________________________________________________
Page 20 of 26
664 665
666 667
CITY AND COUNTY OF SAN FRANCISCO # FC121R SAN FRANCISCO FIRE DEPARTMENT VEH # 4500072
RQFC12000042 ITSF12000686/CD
ATTACHMENT C EQUIPMENT SPECIFICATIONS FOR
SUPPLIED 2850-1000 GALLON CAPACITY DIESEL-GASOLINE ALUMINUM TANKER
TO BE REMOUNTED ON A NEW 3 AXLES, 60,000 GVWR CAB AND CHASSIS
LAST REVISION 4/6/2012
______________________________________________________________________
Page 21 of 26
668 669
670
671
672
673
674
675
676
677
678
CITY AND COUNTY OF SAN FRANCISCO # FC121R SAN FRANCISCO FIRE DEPARTMENT VEH # 4500072
RQFC12000042 ITSF12000686/CD
ATTACHMENT C EQUIPMENT SPECIFICATIONS FOR
SUPPLIED 2850-1000 GALLON CAPACITY DIESEL-GASOLINE ALUMINUM TANKER
TO BE REMOUNTED ON A NEW 3 AXLES, 60,000 GVWR CAB AND CHASSIS
LAST REVISION 4/6/2012
______________________________________________________________________
Page 22 of 26
679
680
681
682
ATTACHMENT D 683
BID EXCEPTION SHEETS 684 Return with Bid if any exceptions are taken 685
686 687 Please Note: All exceptions to the City’s bid requirements must be listed on the sheets provided. 688 Only those exceptions that are listed on the sheets provided will be evaluated. Any material 689 exceptions may result in the rejection of the bid and the bidder will not receive further 690 consideration. 691
692
*Section Title, Line Number, & Page Number:_______________________________________ 693
694
Description:___________________________________________________________________695
__________________________________________________________________________ 696
Alternative:___________________________________________________________________697
__________________________________________________________________________ 698
699
*Section Title, Line Number, & Page Number:_______________________________________ 700
701
Description:___________________________________________________________________702
__________________________________________________________________________ 703
Alternative:___________________________________________________________________704
__________________________________________________________________________ 705
706
*Section Title, Line Number, & Page Number:_______________________________________ 707
708
Description:___________________________________________________________________709
__________________________________________________________________________ 710
Alternative:___________________________________________________________________711
__________________________________________________________________________ 712
713
CITY AND COUNTY OF SAN FRANCISCO # FC121R SAN FRANCISCO FIRE DEPARTMENT VEH # 4500072
RQFC12000042 ITSF12000686/CD
ATTACHMENT C EQUIPMENT SPECIFICATIONS FOR
SUPPLIED 2850-1000 GALLON CAPACITY DIESEL-GASOLINE ALUMINUM TANKER
TO BE REMOUNTED ON A NEW 3 AXLES, 60,000 GVWR CAB AND CHASSIS
LAST REVISION 4/6/2012
______________________________________________________________________
Page 23 of 26
*Section Title, Line Number, & Page Number:_______________________________________ 714
715
Description:___________________________________________________________________716
__________________________________________________________________________ 717
Alternative:___________________________________________________________________718
__________________________________________________________________________ 719
*Section Title, Line Number, & Page Number:______________________________________ 720
721
Description:___________________________________________________________________722
__________________________________________________________________________ 723
724
Alternative:___________________________________________________________________725
__________________________________________________________________________ 726
727
*Section Title, Line Number, & Page Number:_______________________________________ 728
729
Description:___________________________________________________________________730
__________________________________________________________________________ 731
732
Alternative:___________________________________________________________________733
__________________________________________________________________________ 734
735
*Section Title, Line Number, & Page Number:_______________________________________ 736
737
Description:___________________________________________________________________738
__________________________________________________________________________ 739
740
Alternative:___________________________________________________________________741
__________________________________________________________________________ 742
743
*Section Title, Line Number, & Page Number:_______________________________________ 744
745
CITY AND COUNTY OF SAN FRANCISCO # FC121R SAN FRANCISCO FIRE DEPARTMENT VEH # 4500072
RQFC12000042 ITSF12000686/CD
ATTACHMENT C EQUIPMENT SPECIFICATIONS FOR
SUPPLIED 2850-1000 GALLON CAPACITY DIESEL-GASOLINE ALUMINUM TANKER
TO BE REMOUNTED ON A NEW 3 AXLES, 60,000 GVWR CAB AND CHASSIS
LAST REVISION 4/6/2012
______________________________________________________________________
Page 24 of 26
Description:___________________________________________________________________746
__________________________________________________________________________ 747
Alternative:___________________________________________________________________748
__________________________________________________________________________ 749
750
*Section Title, Line Number, & Page Number:_______________________________________ 751
752
Description:___________________________________________________________________753
__________________________________________________________________________ 754
755
Alternative:___________________________________________________________________756
__________________________________________________________________________ 757
758
759
*Section Title, Line Number, & Page Number:_______________________________________ 760
761
Description:___________________________________________________________________762
__________________________________________________________________________ 763
764
Alternative:___________________________________________________________________765
__________________________________________________________________________ 766
767
*Section Title, Line Number, & Page Number:_______________________________________ 768
769
Description:___________________________________________________________________770
__________________________________________________________________________ 771
772
Alternative:___________________________________________________________________773
__________________________________________________________________________ 774
775
*Section Title, Line Number, & Page Number:_______________________________________ 776
777
CITY AND COUNTY OF SAN FRANCISCO # FC121R SAN FRANCISCO FIRE DEPARTMENT VEH # 4500072
RQFC12000042 ITSF12000686/CD
ATTACHMENT C EQUIPMENT SPECIFICATIONS FOR
SUPPLIED 2850-1000 GALLON CAPACITY DIESEL-GASOLINE ALUMINUM TANKER
TO BE REMOUNTED ON A NEW 3 AXLES, 60,000 GVWR CAB AND CHASSIS
LAST REVISION 4/6/2012
______________________________________________________________________
Page 25 of 26
Description:___________________________________________________________________778
__________________________________________________________________________ 779
Alternative:___________________________________________________________________780
__________________________________________________________________________ 781
782
*Section Title, Line Number, & Page Number:_______________________________________ 783
784
Description:___________________________________________________________________785
__________________________________________________________________________ 786
Alternative:___________________________________________________________________787
__________________________________________________________________________ 788
789
*Section Title, Line Number, & Page Number:_______________________________________ 790
791
Description:___________________________________________________________________792
__________________________________________________________________________ 793
794
Alternative:___________________________________________________________________795
__________________________________________________________________________ 796
797
*Section Title, Line Number, & Page Number:_______________________________________ 798
799
Description:___________________________________________________________________800
__________________________________________________________________________ 801
802
Alternative:___________________________________________________________________803
__________________________________________________________________________ 804
*Section Title, Line Number, & Page Number:_______________________________________ 805
806
Description:___________________________________________________________________807
__________________________________________________________________________ 808
CITY AND COUNTY OF SAN FRANCISCO # FC121R SAN FRANCISCO FIRE DEPARTMENT VEH # 4500072
RQFC12000042 ITSF12000686/CD
ATTACHMENT C EQUIPMENT SPECIFICATIONS FOR
SUPPLIED 2850-1000 GALLON CAPACITY DIESEL-GASOLINE ALUMINUM TANKER
TO BE REMOUNTED ON A NEW 3 AXLES, 60,000 GVWR CAB AND CHASSIS
LAST REVISION 4/6/2012
______________________________________________________________________
Page 26 of 26
809
Alternative:___________________________________________________________________810
__________________________________________________________________________ 811
812
*Section Title, Line Number, & Page Number:_______________________________________ 813
814
Description:___________________________________________________________________815
__________________________________________________________________________ 816
817
Alternative:___________________________________________________________________818
__________________________________________________________________________ 819
820