Welcome to HAI’s Training Course. In this day long course, we will show you how to install, set-up and program a home automation system.

Introduction Introduction

Page 3: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

AgendaAgenda Specifications Connections PC Access Connections Programming Setup

• Codes

• Programs Dial• Arming• Names/Voices• Miscellaneous

Installer Setup • Control• Zones• Communicator• Areas• Temperature• Miscellaneous• Expansion

• Lifestyle Applications

Page 4: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

SpecificationsSpecifications

OMNIPRO II SPECIFICATIONSController Maximum Group Current Outputs:

Console: backlight off - 35 mA; backlight on - 100 mA

OUTPUTS 1 - 8 100 mA

Devices: AUX 12 VDC, SWITCH 12 VDC, CONSOLE, and OUTPUTS 1 - 8: 1 A

Horn: INT HORN and EXT HORN: 1 A

Controller Maximum Individual Current Outputs:

Devices: (Do not exceed 1 A total)

AUX 12 VDC 1 A

SWITCH 12 VDC 1 A

CONSOLE 1 A

Operating 32 - 122 degrees F (0 - 50 degrees C)

Transformer: 24 VAC, 1.67 amps, 40 VA

Battery: Rechargeable Lead-Acid, 12 Volts, 7 Ah

Page 5: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

SpecificationsSpecifications cont. cont.

OMNI II SPECIFICATIONSTypical Current Consumption at Nominal Voltage:

Console: backlight off - 35 mA; backlight on - 100 mA

Controller Maximum Group Current Outputs:

Devices: AUX 12 VDC, SWITCH 12 VDC, CONSOLE, and OUTPUTS 1 - 8: 1 A

Horn: INT HORN and EXT HORN: 1 A

Controller Maximum Individual Current Outputs:

Devices: (Do not exceed 1 A total)

AUX 12 VDC 1 A

SWITCH 12 VDC 1 A

CONSOLE 1 A

OUTPUTS 1 - 8 100 mA

Operating 32 - 122 degrees F (0 - 50 degrees C)

Transformer: 24 VAC, 1.67 amps, 40 VA

Battery: Rechargeable Lead-Acid, 12 Volts, 7 Ah

Page 6: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

OMNILT SPECIFICATIONSTypical Current Consumption at Nominal Voltage:

Console: backlight off, 35 mA

backlight on, 100 mA

CONTROLLER OUTPUTS UL RATINGS MAXIMUM

Devices: AUX 12 VDC, CONSOLE, and OUTPUTS 1 and 2: 200 mA 500 mA

Bell: BELL 350 mA 1 A

Outputs: OUTPUTS 1 and 2, each, maximum: 100 mA 100 mA

Backup: Required battery backup hours: 24 hours

Battery: Recommended Battery: 12 Volts, 7 Ah

Operating 32 - 122 degrees F (0 - 50 degrees C)

Transformer: 16.5 VAC, 40 VA, 50/60 Hz

SpecificationsSpecifications cont. cont.

Page 7: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

ConnectionsConnections

Page 8: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Ground the Controller “Earth Ground” terminal to a cold water pipe or to a 4-foot ground rod to preserve it’s built in transient protection.

1)Ground ConnectionGround Connection

Page 9: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

24vac40 VA Transformer

Connect a 24 volt 40 VA transformer to the 24VAC Input (2nd & 3rd input) in the left corner of the first terminal strip. Note: a) Be sure you connect wires to inputs 2 & 3. Do not connect transformer to the first input (Ground).

b) Do not plug in transformer until all devices are wired to Controller

c) Make sure controller is not plugged into a switched outlet.

Transformer Connection Transformer Connection Omni II / OmniPro IIOmni II / OmniPro II

Page 10: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

16.5vac40 VA Transformer

2)

Connect a 16.5 volt 40 VA transformer to the 16VAC Input (2nd & 3rd input) in the left corner of the first terminal strip. Note: a) Be sure you connect wires to inputs 2 & 3. Do not connect transformer to the first input (Ground).

b) Do not plug in transformer until all devices are wired to controller

c) Make sure controller is not plugged into a switched outlet.

Transformer Connection Transformer Connection Omni LTOmni LT

Page 11: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Connect the BLACK battery wire to the minus (-) terminal on the Battery. ****DO NOT connect the red wire at this time. ****DO NOT reverse the connections; the battery fuse will blow. ****7 Ah Battery required

Battery HookupBattery Hookup

+

_

+ -

Page 12: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Use 4-conductor 22 gage wire minimum, 1000 feet maximum length. Consoles can be homerun or daisy chained. This length shall be divided by the total number of consoles at the end of the run.

Red 12V Terminal

Black GND Terminal

Yellow (A) Terminal

Green (B) Terminal

4) Console/ OmniTouch HookupConsole/ OmniTouch Hookup

Maximum current draw from Auxiliary and Console terminal is 1 Amp for Omni II and OmniPro II and for the Omni LT it is a Maximum of 500mA. Be sure to add total current draw from all power devices. If above the limit, an Auxiliary power supply is required. Power supply must have common ground with controller. See current draw listings below for consoles

Omni Console- 33A00-1 = 40mA – 100mA (active)

OmniTouch- 32A00-1 = 350mA

RE

D

BL

AC

K

YE

LL

OW

GR

EE

N

Page 13: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Connect to Green and the Red wires to the incoming line and the Brown and gray to the return to the house phones.

If required connect a RJ31X jack as shown in the following diagram

Note: Make sure all house phones come after controller. The polarity must be correct for proper operation of the phone access feature.

Phone Connection Omni LTPhone Connection Omni LT

Page 14: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Connect to Green and the Red wires to the incoming line and the Brown and gray to the return to the house phones. If required connect a RJ31X jack as shown in the following diagram

Note: Make sure all house phones come after controller. The polarity must be correct for proper operation of the phone access feature.

Phone Connection Phone Connection Omni II & OmniPro IIOmni II & OmniPro II

Page 15: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Sounder ConnectionsSounder ConnectionsOmni LTOmni LT

• Sounders can draw up to 1 amp MAXIMUM on the Bell output

• Use a relay connected to an auxiliary power supply if a higher current draw is required.

• If there there is a slight hum coming from the Siren, strap the bell output out with a 1k resistor.

•If a siren is not being used, Strap bell outputs out with a 1k resistor.

•When system is not in an alarm, the siren output will measure 10.40VDC. When in alarm, it will measure 13.75. The small amount of voltage is how we supervise the output

Page 16: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Sounder ConnectionsSounder ConnectionsOmni II & OmniPro IIOmni II & OmniPro II

• Sounders can draw up to 1 amp MAXIMUM, split between the Interior and Exterior Horn Outputs.

• Use a relay connected to an auxiliary power supply if a higher current draw is required.

• If there there is a slight hum coming from the Siren, strap the bell output out with a 1k resistor.

•If a siren is not being used, Strap bell outputs out with a 1k resistor.

• When system is not in an alarm, the siren output will measure 10.40VDC. When in alarm, it will measure 13.75. The small amount of voltage is how we supervise the output.

Page 17: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Two Wire Smoke ConnectionTwo Wire Smoke ConnectionOmni LTOmni LT

All two wire smokes must be run in parallel and have an EOL resistor at the end of the line.

Be sure to move jumper to SMK position.

All two wire smokes must be wired to zone 8 only.

Page 18: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Two Wire Smoke ConnectionTwo Wire Smoke ConnectionOmni II & OmniPro IIOmni II & OmniPro II

All two wire smokes must be run in Parallel and have an EOL resistor at the end of the line.

Be sure to move jumper to SMK position.

All two wire smokes must be wired to zones 1 – 4 only.

Page 19: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

4-Wire Smoke Connection4-Wire Smoke ConnectionOmni LTOmni LT

• Use normally open (closed for alarm) four-wire 12volt smokes

• An End of Line Power Supervision Relay Module is required for UL installations.

• Install a 1000-ohm End-of-Line resistor as shown

•Power the smoke detector from Aux 12V or Output 2 as a SWITCHED POWER OUTPUT

•When connected to Zone 8, the Jumper must be in SMK position

If 4 wire smokes are going on the same zone, they must be wired in Parallel.

4 wire smokes can be placed on their own zone and can be wired to all zones.

Page 20: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

4-Wire Smoke Connection4-Wire Smoke ConnectionOmni II & OmniPro IIOmni II & OmniPro II

If 4 wire smokes are going on the same zone, they must be wired in Parallel. 4-wire smokes can be placed on their own zone and can be wired to all zones. EOL resisters are required for all smokes and must be placed at the last smoke. A Power Supervision relay is required if power supervision is necessary

• Use normally open (closed for alarm) four-wire 12volt smokes

• An End of Line Power Supervision Relay Module is required for UL installations.

• Install a 1000-ohm End-of-Line resistor as shown

•Power the smoke detector from Switch 12V or an Output configured as a SWITCHED POWER OUTPUT

•When connected to Zones 1-4, the appropriate Zone Jumper must be in SMK position

PLATEBOTTOM

MODEL 2112/24TRSYSTEM SENSOR

HAI MODEL 1503A00111K OHM EOL RESISTOR

FOUR-WIRE DETECTORS ON ZONES 1-4

ZONE

ZONE

+12V

GND

YELLOW

BLACK

RED

GREEN

BLACK

VIOLET

VIOLET

GREEN

YELLOW

BLACK

REDRED

MODEL A77-716BSYSTEM SENSOR

RELAYSUPERVISIONEOL POWER

ZO

NE

PO

WE

R

GREEN

ZO

NE VIOLETRELAY

VIOLET

1K OHM EOL RESISTORHAI MODEL 1503A0011

YELLOW

RED+12V

MODEL A77-716BSYSTEM SENSOR

SUPERVISIONEOL POWER

GND

BLACK

RED

PO

WE

R

BLACK

MODEL 2112/24TRSYSTEM SENSOR

ZONE

ZONE GREEN

YELLOW

BLACK

RED

PLATEBOTTOM

BLACKREDYELLOWGREEN

GREEN

REDBLACKYELLOW

CORRESPONDING ZONE JUMPERS J11-J14SUPERVISED FIRE OR GAS ZONE, THE WHEN Z1-Z4 IS CONFIGURED AS A

MUST BE IN "SMK" POSISTION

FOUR-WIRE DETECTORS ON ZONES 5-16

Page 21: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

RC Series Thermostat ConnectionRC Series Thermostat ConnectionOmni LTOmni LT

• Run a 3 or 4 conductor wire from the HAI system to the Omni-stat.

• All Omni-Stats are connect to the controllers TSTAT input.

• Make sure black and red wire are securely connected to each other. If they are not, you will have communication problems.

• Address each Thermostat separately in order to communicate to HAI.

(press Program 3X, then press Fan, use down arrow key to change address)

• Under Setup/Installer/ Temps in the HAI programming, enable thermostats being used.

• Disable Internal thermostat programming in thermostat section #03.

Page 22: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

RC Series Thermostat ConnectionRC Series Thermostat ConnectionOmni II & OmniPro IIOmni II & OmniPro II

• Run a 3 or 4 conductor wire from the HAI system to the Omni-stat.

• All Omni-Stats are connect to the controllers zone 16 and Output 8

• Make sure black and red wire are securely connected to each other. If they are not, you will have communication problems.

• Address each Thermostat separately in order to communicate to HAI.

(press Program 3X, then press Fan, use down arrow key to change address)

• Under Setup/Installer/ Temps in the HAI programming, enable thermostats being used.

• Disable Internal thermostat programming in thermostat section #03.

Page 23: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

• Each Model 31A00-2 requires one zone input for temperature and one zone input for humidity. Run a 4-conductor wire from the controller location to each Model 31A00-2. The humidity sensor can be used without using the temperature sensor.

• If a high and a low Set point is Desired for temperature or Humidity, connect a jumper wire from the positive of one zone to the positive of another zone.

• Program the zone type for the temperature output as an Outdoor Temperature (Type 81), Temperature (Type 82), or Temperature Alarm (Type 83) based on the application. Only one zone can be defined as an Outdoor Temperature zone.

31A00-2 Outdoor Temperature & 31A00-2 Outdoor Temperature & Humidity SensorHumidity Sensor

Page 24: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

• Run a twisted pair, shielded cable from the OmniStat to the Remote Temperature Sensor location. For distances up to 100 feet, typical twisted pair, PVC-insulated, shielded cable may be used. For distances from 100-150 feet, twisted pair with polypropylene insulated conductors, shielded must be used. For distances from 150-250 feet, twisted pair with foam-polyethylene insulated conductors, shielded must be used. Wire runs must not exceed 250 feet.

• Disconnect the thermostat from the base. Locate the 3 solder holes on the lower right side of the thermostat PCA marked J4.

• Using a clean soldering iron and safety glasses, carefully solder the supplied connector to the soldering holes as shown.

• Open cover to the Model 23A00-1 Remote Temperature Sensor. Connect the data wires of the shielded cable to the terminal block on the temperature sensor. Wrap the shield around the jacket of the cable and tape.

•At the OmniStat location, connect the Black conductor of the supplied cable to the shield using the supplied wire splices. Connect the Green conductors of the supplied cable to the data wires using the supplied wire splices.

•Carefully clip off the existing thermister (temperature sensing device) from the thermostat using a pair of wire cutters

Remote Surface/Recessed Remote Surface/Recessed Temperature SensorTemperature Sensor

Page 25: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Hardwire Expander Hardwire Expander Omni LTOmni LT

Ribbon Cable

When connecting 2nd & 4th Expansion Module connect ribbon cable from J2 to J2

•When adding a expansion modules, secure them to stand offs and connect them using supplied ribbon cables.

•To add more than one expansion Module, connect to J2 and address board using address jumper JP1

When connecting 1st & 3rd expansion module, such as an ALC, Zone Expander, or Serial module connect ribbon cable from J1 to J1

If adding more than one Expansion Module, be sure to address it with jumper JP1

Page 26: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Hardwire Expander Hardwire Expander Omni II & OmniPro IIOmni II & OmniPro II

Ribbon Cable

When connecting 2nd & 4th Expansion Module connect ribbon cable from J2 to J2

J2 J1

•When adding a Expansion Module, secure them to stand offs and connect them using supplied ribbon cables.

•To add more than one Expansion Module, connect to J2 and address board using address jumper JP1

When connecting 1st & 3rd expansion module, such as an ALC, Zone Expander, or Serial module connect ribbon cable from J1 to J1

If adding more than one Expansion Module, be sure to address it with jumper JP1

Page 27: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Two-Way Voice ModuleTwo-Way Voice ModuleOmni LTOmni LT

When connecting the Two-Way Voice Module to an Omni LT, route the cable(model 10A11) to the left side of the controller into “J2”.

***** Make sure red wire on cable should be to the Left of the connector****

**** Make sure that the connector is aligned with the pins on “J2”****

Mount Two-way Voice Module to side of can using double stick tape or by drilling holes and using stand-offs supplied

Red Wire faces to the left

Page 28: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Two-Way Voice ModuleTwo-Way Voice ModuleOmni II & OmniPro IIOmni II & OmniPro II

When connecting the Two-Way Voice Module to an Omni Pro II, route the cable(model 10A11) to the left side of the controller into “J2”.

***** Make sure red wire on cable should be to the top of the connector****

**** Make sure that the connector is aligned with the pins on “J2”****

Mount Two-way Voice Module to side of can using double stick tape or by drilling holes and using stand-offs supplied

J2

Red Wire

Page 29: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Expansion EnclosureExpansion EnclosureOmniPro II OnlyOmniPro II Only

• The Expansion Enclosure communicates with the controller using the same wires that connect the consoles to the controller.

The communications wires for the Expansion Enclosure and consoles may be homerun to the controller or daisy-chained to each other.

Connect the terminals marked "A" and "B" on the Expansion Enclosure to the corresponding terminals on the controller or console.

•The Expansion Enclosure may be located up to 1000 feet away from the controller.

• A common ground wire must be wired to the controller.

12)G

roun

d w

ire

BA

Page 30: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Installing Installing PC AccessPC Access

Page 31: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Installing PC AccessInstalling PC Access

When installing PC Access, you will see this screen show up. Enter your Name, Company name, and Serial number to continue. Your serial number can be found on the CD sleeve of your PC Access.

Make sure to Register your copy of PC Access. Free upgrades are only available for registered software

Page 32: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Installing PC AccessInstalling PC Access

After following the prompts and loading the software, double click on the PC Access Icon on your Desktop. You will receive this window. Enter the default Password which is “password”. Then press “OK”

Page 33: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

When Running the program for the first time, you will receive this window after logging in. Enter a code that you can remember.

******* DO NOT FORGET THIS CODE!!!! *************

Installing PC AccessInstalling PC Access

Page 34: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Connecting PC to Omni ControllerConnecting PC to Omni Controller

After Starting the program, Go to “File” then choose “ New”. A “Save File” screen will pop up. After creating a name and choosing save, this window will come up. Choose the type of Omni controller you are programming. Be sure you enter the correct Controller type.

Page 35: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

This is your first screen. It contains contact information on your client. Enter in the customers name, Address Phone number and any remarks you may have for this account.

Connecting PC to Omni ControllerConnecting PC to Omni Controller

Page 36: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

If you are connecting through a serial port, go to your Windows device manager then to ports and find out what port your communications port is. Then go to your PC Access / configure and then Serial. You will see this screen. Enter your Com port and baud rate. The baud rate of 9600 is standard.

Connecting PC to Omni ControllerConnecting PC to Omni Controller

Page 37: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

In the bottom right hand corner, it should say “ON-LINE”. If you are not receiving this statement, one of four things can be wrong.1. Your Com Port is incorrect2. Your DB-9 Connector is broken or not plugged in3. A program has taken over your comport and is not releasing it4. Your Com port is broken.The System does not have to be connect to the PC in order to get an online Status.

Connecting PC to Omni ControllerConnecting PC to Omni Controller

Page 38: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

You may have to contact your modem manufacturer to find out what the string commands are that disables “error correction” and “Data compression”. Once you get those commands, enter them in Initialization #2 & #3 and then enable them in the bottom right corner.

Connecting PC to Omni ControllerConnecting PC to Omni Controller

If you are connecting through a modem, go to your Device manager and find out what port your modem is on. Then enter that port number in this window under configure then modem. Make sure you put your baud rate on 9600 , 2400, or 300 baud rate.

Page 39: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

To connect using Telephone access from off site follow the following steps

a) With a phone ,on the same line that your PC is connected to, call the number the controller is connected to. Let it ring once and then hang up.

b) Count to ten and then call the number again.

c) Once you hear a beep, enter Code 1 or the installer code. You will hear a menu.

d) When you hear the menu, press # # 1

e) The system will ask you for a code again. Enter your code again. After entering your code, the system will begin to communicate. On your PC Access, press connect, then modem , then online. After you hear your modem connect, hang up the phone. You will be connected about 10 seconds later.

Connecting PC to Omni ControllerConnecting PC to Omni Controller

Page 40: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training
Page 41: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Setup - CodesSetup - Codes

All Omni security codes are 4 digits in length. To set up a code from the Setup menu from the console, press the 1 (CODES) key. (Valid codes 0001-9999) (0000 = Disable)

Assign an Authority Level. Choose from Master, Manager, and User.

Choose the Areas that the codes can access

Choose the valid times these cards can be used.

Page 42: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Basic ProgrammingBasic Programming

HAI controllers are time and event driven

A program will execute when– Time match occurs

– An Event match occurs

The controller is constantly searching for a

time match or a change of state.

Page 43: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Program Line StructureProgram Line Structure

When: A time match or an event kicks off execution of a

program line.

Command: Every program has a command to perform as a

result of the When.

AND IF: The ‘&IF’ statement is optional in all programming

lines. It is used as a conditional. As the controller watches all of

the inputs to the system, it is constantly looking for matches for

the ‘When.’ When the match occurs, the system looks for a

conditional (&IF), to see if the condition “is true” or “is NOT

true.” If the condition “is true” it executes the Command. If the

conditional “is NOT true” the Command is not executed.

Page 44: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

When, Command, IfWhen, Command, If

WHEN Time of day, sunrise, sunset User buttons (Romantic Eve) Control (a unit goes on or off) Security (mode changes) Zone (zone opens or closes) All On All Off Alarm X-10 (incoming) Misc..

– Phone Dead / Phone Line Ring– Phone On Hook / Off Hook– AC ON / AC OFF– Battery Low / Battery OK– DCM Fail / DCM OK

COMMAND Control (on, off, dim, level) Security (mode, bypass, restore) Button (run a button) All On/ All Off Scene (activate a scene) Temperature settings Message (show, say, send, phone)

& IF Unit (on or off) Security (mode) Zone (open or closed) Time (within a window) Misc None, Never, Light, Dark, Phone Dead /

Ring, On Hook / Off Hook, AC On / Off, Battery Low / OK

Page 45: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

When: Time ProgramsWhen: Time Programs

Two types: Day of Week or Date

Weekly: Has one or more days (MTWTFSS)

– Example 1: Sunset MTWTFSS: Front Porch Light On

– Example 2: 10:30 PM MTWTF: Front Porch Light Off

Date: Has a day and month (12/03)

– Run Once:

– Example: 3:00PM 6/05: Thermostat cool setting to 74.

– Run Annually:

– Example: 7:30AM 12/03: Show “Jays Birthday”

Page 46: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

When: Event ProgramsWhen: Event Programs

Run program line when something happens

– When Front Door Not Ready (open) Entry Light On

– When Hall Motion Not Ready (open) Hall Light On for 10 minutes

– When Arm Away: Set Downstairs Heat to 65

– When Arm Away: Set Downstairs Cool to 85

– When “Romantic Eve”: Dining Lights to 50%

Page 47: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

CommandsCommands

Control (on, off, dim, level)

Security (mode, bypass, restore)

Button (run a button)

All On

All Off

Scene (activate a scene)

UPB Link

RadioRA Phantom

Temperature settings

Message (show, say, send, phone)

Page 48: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

ConditionalsConditionals

AND IF…– When Front Door Not Ready (open)

& IF DARKEntry Light On

– When 4:00 PM MTWTF--:&IF AWAYDownstairs Cool Setting 75

Page 49: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

WorkshopWorkshop

WHEN Front Door NOT READY & IF DARK: Front Entry Lt ON

– The controller has the above line of programming

– 5:58 PM the Front Entry light is off

– 5:59 PM the homeowner walks in the Front Door and leaves the door open

– 6:00 PM Sunset occurs

– 6:01 PM is the Front Entry light on or off?

It is OFF. The line is only executed when the Front Door is opened. At that moment sunset had not occurred.

What would we do to make it go on at sunset if the front door was open?

WHEN Sunset MTWTFSS &IF Front Door NOT READY: Front Entry Lt ON

Page 50: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Buttons: Creating a Scene (Macro)Buttons: Creating a Scene (Macro)

When “EXIT”: Security AWAY

When “EXIT”: All lights Off

When “EXIT”: All Thermostats Cool set back 80

When “EXIT”: All Thermostats Heat set back 60

When “EXIT” & IF Dark: RUN “Lights On” *

When “Lights On”:, Kitchen Light On 50 %

When “Lights On”: Family Room on 40 %

When “Lights On”: Master BedRm ON 25 %26

Page 51: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

PC AccessPC Access

Create programs in PC Access Review, edit delete, cut, paste,

copy

Search for programs Download to controller

Page 52: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

PC Access: TipsPC Access: Tips

Page 53: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Setup DialSetup Dial

Settings:

Telephone access – This option allows you to turn the local (in-house) and remote telephone control feature on and off

Answer outside call- allows access from outside through telephone. Choosing “No” will prevent this but still allow local access

Remote commands OK- allows commands to be performed through a remote telephone. Local access can still issue commands when set to “No”

Dial mode – Specifies the type of dialing used when the Omni dials out.

Rings before Answer – The amount of rings before Omni series controller will pick up phone.

My Phone Number – the phone number that will be announced when the Omni dials out in the event of an alarm

Dial Order – The dial order in which call all will be placed if an alarm is activated

Page 54: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Setup Dial cont..Setup Dial cont..

Phone numbers Phone numbers 1-8 – These numbers

are stored in the system. In the even of an alarm, these numbers are dialed in the order that is set up in the Dial Out Order for the particular type of alarm

You can cause the system to pause for 2 seconds between digits of numbers by Putting a (T) in the number or by pressing the DAY key on the console. For (*) press the NIGHT key and for (#) press the AWAY key.

Phone numbers can be up to 24 digits in length

Page 55: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Setup – ArmingSetup – Arming

Entry Delay – Program the Entry delay for each Area. This delay will be the time you get to turn off the system.

Exit Delay - Program the Exit delay for each Area. This delay will be the time you get to exit the secured area

Audible exit delay- This feature is an audible indication from the console beeper while the exit delay is in effect.

Entry/Perimeter Chime – When an Entry or Perimeter door is opened, the consoles will beep once.

Quick Arm – allows you to press the desired mode key without having to enter a code

Auto Bypass – allows the controller to bypass an open zone when the system is armed.

All on for alarm- This option will instruct the Omni system to execute an X-10 All on command in the event any alarm occurs.

Beep on trouble – If the Controller detects any troubles with itself ot one of the zones connected to it, it will display a message on the screen and beep the console twice per second, continuously. To silence, press the * key.

Page 56: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Setup- Names/VoicesSetup- Names/Voices

Names – The system can be set up to display descriptive names such as “ FRONT DOOR”, “JOHN’S BEDROOM” etc… for zones, units buttons, codes, temperatures, areas, and messages. If you are using an OMNITOUCH, you must name anything you want to be viewed or controlled.

Voices – The Omni series controllers can be set up to speak descriptive names such as “Front Door” for control zones, units, buttons, codes, temperatures, areas, and messages.

Page 57: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Setup – MiscellaneousSetup – Miscellaneous

Settings High Security – In this mode, the

master or manager code is always required to do the following functions:

Any Control functions Any Temperature Control View Event Log Access system from a local phone

Freeze Alarm – If there are one or more Thermostats or PESMs in a system, they can also be used to detect a freeze condition. Alarm is activated when temperature falls below 40 degrees. Alarm will not clear until it reaches 45 degrees.

Announce Alarms- If the HAI Two-way Audio Module is being used in a system, this option enables the system to speak the type of alarm and zone over a speaker on the premises.

Location – Enter in the correct Latitude, Longitude , Time zone and side of the Prime Meridian the system is on so it can properly calculate the time of sunrise and sunset. Flash for Alarm - You may enter one unit number that will flash on and off continuously when the alarm is activated.

Page 58: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Setup – MiscellaneousSetup – Miscellaneous

Control - House codes

Enable All Off – This feature allows you to choose if X-10 House Code will respond to All Off Commands.

Enable All On – This feature allows you to choose if X-10 House Code will respond to All On Commands.

Format- Choose from Standard (Preset Dim Commands), Extended (Level Command), Lightolier’s Compose, UPB (Universal Power Bus), and RadioRA

Page 59: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Setup – MiscellaneousSetup – Miscellaneous

Time Clocks

TC1, TC2, TC3 – There are three Time Clocks in the system that are used to conditionalize programs. They are used solely to define time periods during the week when certain programs should be enabled or disabled to execute.

Page 60: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Setup – MiscellaneousSetup – Miscellaneous

Daylight Savings Time

DST – The Omni Series automatically calculates the day of daylight savings time each year. It also adjusts the “time of day” each time daylight saving time begins and ends

Page 61: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Installer ProgrammingInstaller Programming

The Following pages can only be programmed with the Dealer configuration Software or through the console with the Installer code.

PC ACCESS 1105W

Page 62: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Setup – Installer – ControlSetup – Installer – Control

Control House Code – The base house code

for units 1-16 and is referenced as house code 1. The house code for units 17-32 is the next house code after the base house code, or house code ‘B” if the base house code is “A”

X-10 3 Phase – This setting whether the X-10 signal is transmitted only at zero crossing for single phase electrical systems or transmitted at 0, 60, and 120 degrees for three phase electrical systems.

UPB Network- Address – Network address that the

UPB devices are programmed to in the UPB Upstart

Password – Password programmed in the UPB Upstart for the Network

Output Types – An Output type must be specified for each of the voltage outputs and for the interior and exterior horn outputs.

Page 63: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Setup – Installer - ZonesSetup – Installer - Zones

Zone resistors – This item is used to specify if the 1000-ohm end-of-line zone resistors will be used with the inputs on the controller and zone expanders (this does not effect Expansion Enclosures or Fire applications)

Expansion enclosures – Expansion Enclosures can be used to add additional zones to the OmniPro II system. Each enclosure adds 16 zones to the system and eight Outputs. You must specify the amount of enclosures.

Zone Types – This option specifies the zone type for each zone. If the zone is being used for security purposes, it cannot be programmed to auxiliary.

Page 64: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Setup – Installer Communicator Setup – Installer Communicator

Account

Phone number 1 – Enter the First Phone number that will be dialed for Central Station Monitoring.

Phone number 2 - Enter the second Phone number that will be dialed for Central Station Monitoring.

DCM Type- This item is used to select the transmitting parameters of the digital communicator.

Two-way Audio – this item enables hands free audio communication between your customer’s premises and the central station or off site phone.

Test Time – The DCM can be programmed to automatically send a test code to the Monitoring facility on a periodic basis.

Page 65: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Setup – Installer Communicator Setup – Installer Communicator

General General – listed are reporting codes for 4/2

format, however if you want to disable reporting of any of these codes for contact ID, just enter (00) in the field to disable.

Report Bypass/Restore - When using Contact ID, the Omni series controller automatically sends a reporting code when a zone is automatically bypassed or restored by the controller. To disable this, choose “No”.

Test code- This code is sent to the monitoring facility when using 4/2 format. To disable enter “00”

Cancel code – This code is sent to the monitoring facility when using 4/2 format. To disable enter “00”

Page 66: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Setup – Installer Communicator Setup – Installer Communicator

Zone

Zone – listed are reporting codes for 4/2 format, however if you want to disable reporting of any of these codes for contact ID, just enter (00) in the field to disable reporting (this feature is only valid in Firmware Version 2.6 or higher).

Page 67: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Setup – Installer Communicator Setup – Installer Communicator

Open /Close Report open/close – The

communicator can be setup to send an opening and a closing report by user code.

Other - This is the reporting code for 4/2 format. To disable type “00”.

Page 68: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

AreaArea

Areas Number of areas – choose

the number of areas needed for your application

Assign areas – Next, choose what areas the Units, zones, buttons, messages, and thermostats are going to belong to.

Console – Last, choose what area the console will be assigned to and whether or not it is a global console.

(global means that the console will be able to control all areas)

Page 69: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

TemperatureTemperature

Temperature Format – choose the format that needs to be used

Thermostat types – Choose between Auto/heat/cool , Cool only, Heat Only, or Not Used.

Page 70: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Setup –Installer - MiscellaneousSetup –Installer - Miscellaneous

Page 1 Installer code– The installer code allows the installer

access to the installer setup menu.

Enable PC Access – This enables or disables the PC Access feature

PC Access Code- This code allows Dealers to put an access code in the system that is separate from the customer’s Master code and Installer code. This code can be used on PC Access

Callback number – In response to a request for remote PC Access using Pc Access code, the system will hang up and dial this number back

Out Siren Delay – This delay helps reduce false alarms by signaling the inside first .

Dialout delay – This is the number of seconds that the Omni series controllers waits before making an emergency dial out to the Monitoring facility.

Alarm Reset- This is the time it takes before the Alarm system resets after an alarm

Arming Confirmation – This is a quick pulse given by the outside siren when the alarm system is armed into a security mode.

Verify Fire Alarms – When a zone configured as a fire/Gas is activated, the system will cycle the switched power outputs off for 10 seconds. The switched 12V power output will then be restored and 5 seconds later the zones will be monitored again. If the zone is tripped again within a 2 minute window, the fire alarm will be activated.

Page 71: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Setup –Installer - MiscellaneousSetup –Installer - Miscellaneous

Page 2 Enable Emergency Keys– This enables or

disables the functionality of emergency keys on the Console.

Time format – Allows you to choose between AM/PM or 24 hr.

Date format- allows you to choose between Month /Day and Day/ Month

AC Power Frequency – Set this so appropriate AC power line frequency

Dead line Detect – This option detects if there is a dial tone. If the system will not have a phone line connected to it, set this feature to (0)

Off hook detect – This item adjusts the threshold that is used to determine when the phone line is going off hook.

Pickup after hangup- This item is used to disable the Omni from picking up the phone line after the called party hangs up the line.

Clock Adjust – If the clock on the controller is running faster or slower than the actual time, you can have the controller automatically compensate up to 29 seconds per day. The controller will add or subtract the selected amount of time daily.

Page 72: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Setup –Installer - MiscellaneousSetup –Installer - Miscellaneous

Page 3

Supervise int sndr– This Enables or disables supervision of the Interior Horn Output, which monitors the wiring to the connected sirens.

Supervise ext sndr – This Enables or disables supervision of the Exterior Horn Output, which monitors the wiring to the connected sirens.

Page 73: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Setup – Installer - ExpansionSetup – Installer - Expansion

Expansion Modules 1-4– The Module Type

defines the function of each expansion module on the controller. Module 1 is the module with the ADDR jumper set to 1.

Rate – Serial rate selects the baud rate used for the built-in serial interface on the controller. Select the baud rate for the built-in interface from the list.

Function- The serial Function selects the communication protocol used for the built-in serial interface. To send a message through the serial interface, set it to Pro-Link.

!!!!!!! Serial Address – DO NOT TOUCH THIS OPTION. Leave it set to 0 !!!!!!

Page 74: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training
Page 75: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Security and SafetySecurity and Safety

The porch lights will flash upon a burglary alarm and remain on until the system is reset. (set up item)

Well, guess what – it’s already a trick question! “Flash for Alarm” is actually a set up item – that function is built in. You don’t have to program anything to make that happen.

Page 76: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Security and SafetySecurity and Safety

Fire alarm will shut down HVAC fan, all lights will turn on for safe exit. (3 programs)

When Fire Alarm: all thermostats Mode OFF

When Fire Alarm, all thermostats FAN AUTO

When Fire Alarm, ALL ON

Page 77: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

LightingLighting

Master Bedroom Lamp will come on at 6:00 AM and go

off at 7:30 AM Weekdays. Console will beep and show

“Rise and Shine!” (3 programs) But not on holidays!

(Make a Holiday Flag)

When 6:00 AM MTWTF--: Master Lamp On for 90

minutes. When 6:00 AM MTWTF-- : SHOW “Rise and

Shine!”

When 7:30 AM MTWTFSS: Clear message “rise and

shine!” (we have to do this so it will beep next morning)

continued…

Page 78: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

LightingLighting

Now: let’s introduce a FLAG.

– Unused unit numbers are flags.

– They don’t control anything, but they can be on, off, timed.

Let’s put in some programs to turn the flag on for holidays:When 12:01 AM 12/25: Holiday Flag On

And a program to turn the flag off every night at the end of the day:When 12:00 am MTWTFSS, Holiday Flag OFF

Conditionalize the first two programs:&IF Holiday Flag OFF

Page 79: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

LightingLighting

Hallway ceiling lights turn on at 65% at sunset and go off when “Night Sleep Mode” is activated. (2 programs)

When Sunset: Hall Lights Level 65%. When NIGHT: Hall lights OFF.

Page 80: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Energy ManagementEnergy Management

When Night Mode, set downstairs thermostat to 60 degrees heating and 82 degrees cooling. (2 programs)

When Night: Downstairs Heat setting 60 degrees. When Night: Downstairs Cool setting 82 degrees.

(You could write two more to bring it to comfort levels early in the morning IF in the night mode – not away or vacation, since we’ll have it set back more.)

Page 81: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Energy ManagementEnergy Management

Set Upstairs thermostat to 65 degrees heating, 78 degrees cooling at 11:30 weekdays IF we’re in Night Mode. (2 programs)

11:30 pm MTWTF &IF NIGHT: Upstairs Heat Setting 65.

11:30 pm MTWTF &IF NIGHT: Upstairs Cool Setting 78.

Page 82: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Energy ManagementEnergy Management

When it is mild outside, turn on the fan to circulate air. (2 programs)

The outdoor sensor has a high and a low setting you can set. Set the low to 65, high to 75. If the outdoor temp is between these values, the outdoor temp zone is “secure”. If not, it’s “not ready”.

When Outdoor Temp Not Ready: Thermostat Fan On.

When Outdoor temp Secure: Thermostat Fan Auto.

This keeps the air moving during times when the heat or air is not likely to run much.

Page 83: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Energy ManagementEnergy Management

When Vacation, turn off the electric water heater.

When Vacation, Water Heat OFF.When Security OFF, Water Heat ON.

– (2 programs)

– You can call in and turn the water heat on without turning security off)

Page 84: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

What are the next steps?What are the next steps?

Align yourself with an HAI

Distribution Partner

Purchase a system to install in your

home or office

Sell only what you know & have

tested

Keep it simple

Complete training special forms

Meet requirements to be listed on

HAI web-site

Use “Automation Simplified”

Manual & HAI Web-site as

reference tools

Page 85: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

We would like your Feedback

In Order for us to provide you with the best possible training available we would appreciate it if you would fill out the “Training Program Evaluation” form.

This form will help us adjust our training format so that you may understand our great product better and help you with your install and sales.It will also allow us to provide a more comfortable area for you to learn in.

Thank You

Page 86: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training

Contacts

HAI 5725 Powell Street Suite A New Orleans, LA  70123 Phone: (504) 736-9810Fax: (504) 736-9890Toll Free: 800-229-7256Email: [email protected]

•Ken Piazzi, Western Region Pacific South Territory (CA, NV, and HI)Las Vegas, NVEmail: [email protected]: (702) 648-7500Fax: (702) 648-8484

•Thomas PickralSouth Central Territory (AR, LA, OK, and TX)New Orleans, LAEmail: [email protected]: (504) 736-9810, ext. 242Fax: (504) 736-9890

•Joel MossGreat Lakes Territory (IL, IN, MI, MN, OH, WI, and Manitoba)New Buffalo, MIEmail: [email protected]: (269) 469-9757

•Brett GriffinAtlantic North Territory (DE, NJ, NY, and PA)Philadelphia, PAEmail: [email protected]: (610) 825-7018Fax: (215) 827-5484 •Jeram CorreaNorth Central Territory (IA, KS, MO, NE, ND, and SD)New Orleans, LAEmail: [email protected]: (504) 736-9810 Ext. 240Fax: (504) 736-9890

•Robert PickralSoutheast Territory (AL, FL, GA, and MS)Jacksonville, FLEmail: [email protected]: (904) 221-6803

•Jeff BrinnAtlantic South Territory (DC, KY, MD, NC, SC, TN, VA, and WV)Conover, NCEmail: [email protected]: (828) 464-4923

•Patrick GilliganNew England Territory (CT, MA, ME, NH, RI, VT, Ontario, Quebec, New Brunswick, Nova Scotia, Newfoundland, and Labrador)Cambridge, MAEmail: [email protected]: (617) 868-3890 •Don DecockPacific Northwest Territory (AK, ID, MT, OR, WA, WY, Alberta, and British Columbia)Seattle, WAEmail: [email protected] Phone: (425) 908-7063

•Stephen LeRougeSouthwest Territory (AZ, CO, NM, and UT)Phoenix, AZEmail: [email protected]: (480) 940-4827

Page 87: Click to edit Master text styles Second level Third level Fourth level Fifth level Installation Training