10
Click to edit Master title style • Click to edit Master text styles • Second level • Third level • Fourth level • Fifth level 1 Applies to ALL lighting fixtures containing a Pulse Start or Probe Start Metal Halide Lamp Does Not Apply to High Pressure Sodium Changes are due to an Amendment to UL Standard 1598 Effective September 17, 2010 New MH HID Lamp Containment Rules

Click to edit Master title style Click to edit Master text styles Second level Third level Fourth level Fifth level 1 Applies to ALL lighting fixtures

Embed Size (px)

Citation preview

Page 1: Click to edit Master title style Click to edit Master text styles Second level Third level Fourth level Fifth level 1 Applies to ALL lighting fixtures

Click to edit Master title style

• Click to edit Master text styles

• Second level

• Third level

• Fourth level

• Fifth level

1

Applies to ALL lighting fixtures containing a Pulse Start or Probe Start Metal Halide Lamp

Does Not Apply to High Pressure Sodium

Changes are due to an Amendment to UL Standard 1598

Effective September 17, 2010

New MH HID Lamp Containment Rules

Page 2: Click to edit Master title style Click to edit Master text styles Second level Third level Fourth level Fifth level 1 Applies to ALL lighting fixtures

Click to edit Master title style

• Click to edit Master text styles

• Second level

• Third level

• Fourth level

• Fifth level

2

New MH HID Lamp Containment Rules

The RULE

A pink exclusionary socket requires an “O” open rated lamp

Does not need a bottom lens

A standard white ceramic socket accepts an E rated lamp

Requires a compliant bottom lens

Page 3: Click to edit Master title style Click to edit Master text styles Second level Third level Fourth level Fifth level 1 Applies to ALL lighting fixtures

Click to edit Master title style

• Click to edit Master text styles

• Second level

• Third level

• Fourth level

• Fifth level

3

New MH HID Lamp Containment Rules

Type E & S Lamp in Standard WhiteMogul Socket

Type O Lamp in Standard WhiteMogul Socket

Lens Required with Std White Mogul Socket

Page 4: Click to edit Master title style Click to edit Master text styles Second level Third level Fourth level Fifth level 1 Applies to ALL lighting fixtures

Click to edit Master title style

• Click to edit Master text styles

• Second level

• Third level

• Fourth level

• Fifth level

4

New MH HID Lamp Containment Rules

Type E & S Lamp in Protected PinkMogul Socket

Type O Lamp in Protected PinkMogul Socket

No Lens Required with Pink EX socket

Page 5: Click to edit Master title style Click to edit Master text styles Second level Third level Fourth level Fifth level 1 Applies to ALL lighting fixtures

Click to edit Master title style

• Click to edit Master text styles

• Second level

• Third level

• Fourth level

• Fifth level

5

New MH HID Lamp Containment Rules

Standard Socket Exclusionary Socket

Page 6: Click to edit Master title style Click to edit Master text styles Second level Third level Fourth level Fifth level 1 Applies to ALL lighting fixtures

Click to edit Master title style

• Click to edit Master text styles

• Second level

• Third level

• Fourth level

• Fifth level

6

Pink Socket – No Bottom Lens Required Standard Socket – Bottom Lens Required

New MH HID Lamp Containment Rules

Page 7: Click to edit Master title style Click to edit Master text styles Second level Third level Fourth level Fifth level 1 Applies to ALL lighting fixtures

Click to edit Master title style

• Click to edit Master text styles

• Second level

• Third level

• Fourth level

• Fifth level

7

Timing:

Applies to all MH and PSMH Production after September 17th

Fixtures made prior to September 17th have a valid UL or CSA listing and are good to use.

New MH HID Lamp Containment Rules

Page 8: Click to edit Master title style Click to edit Master text styles Second level Third level Fourth level Fifth level 1 Applies to ALL lighting fixtures

Click to edit Master title style

• Click to edit Master text styles

• Second level

• Third level

• Fourth level

• Fifth level

8

New MH HID Lamp Containment Rules

STOCKED SUPERBAYS:

• BLA-400P8-WH BALLAST HOUSING, 400w PS, STD SOCKET • BLA-400P8-WH-EXBALLAST HOUSING, 400w PS, EX SOCKET• BL-BI REFLECTOR, 14” SPUN ALUM• BL-LB1 REFLECTOR, LOWBAY, 23” DIA• BL-WA22 REFLECTOR, 22” ACRYLIC• BL-LR14 BOTTOM LENS FOR B-LBI, CLEAR GLASS• WA2ENC BOTTOM LENS FOR BL-WA22, CLEAR ACRYLIC

SUPERBAY SALES BOMS:

• BL-400P8-BI-WH-LR14 SUPERBAY, 400w PS, 14” REFL, GLASS BTM LENS

• BL-400P8-LB1-WH SUPERBAY, 400w PS, 23” LOWBAY• BL-400P8-WA22-WH-ENC SUPERBAY, 400w PS, 22” ACRYLIC, ACRY BTM LENS• BL-400P8-BI-WH-EX SUPERBAY, 400w PS, 14” REFL, EX SKT• BL-400P8-WA22-WH-EX SUPERBAY, 400w PS, 22” ACRYLIC, EX SKT

Page 9: Click to edit Master title style Click to edit Master text styles Second level Third level Fourth level Fifth level 1 Applies to ALL lighting fixtures

Click to edit Master title style

• Click to edit Master text styles

• Second level

• Third level

• Fourth level

• Fifth level

9

STOCKED SUPERBAY UNIT PACKS:

• BL-400P8-WA-EX-UPL – 400w PS, QUAD TAP, 22” ACRYLIC, OPEN LAMP, EX SKT• BL-400PV-BC-EX-UPL – 400w PS, FIVE TAP, 14” ALUM, OPEN LAMP, EX SKT• BL-400PV-LB1-WH-UPL – 400w PS, FIVE TAP, 23” LOWBAY, STD LAMP

Make to Order Highbays:

•All Hubbell Lighting highbays, other than those listed above, will be Make to Order (MTO)

•All MTO highbays are required to have either a bottom lens or an exclusionary socket.

Your order will be returned to select a lens or ex socket if these conditions are not met!

New MH HID Lamp Containment Rules

Page 10: Click to edit Master title style Click to edit Master text styles Second level Third level Fourth level Fifth level 1 Applies to ALL lighting fixtures

Click to edit Master title style

• Click to edit Master text styles

• Second level

• Third level

• Fourth level

• Fifth level

10

UL Changes Affecting Hubbell Industrial HID MH and PS Highbays

Who Harmonized UL and CSA Standard 1598

What Will require either an open rated lamp and exclusionary socket or a compliant bottom lens with std mogul socket

Where USA and other countries requiring the protection of a UL/ CSA listing

When Effective on all MH and PS fixtures produced after 9-17-2010

Why To match the UL/CSA Standard with the existing NEC code