Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
Site Plan
W PENDER ST
GR
AN
VILL
E ST
ALLEY OOP
SEYM
OU
R S
T
ROGERSBUILDING
JUNCTION BOX
KIOSK
LAMP STANDARD
MANHOLE
MANHOLE - ELECTRICAL
MANHOLE - SANITARY
PARKING METER
POLE - HYDRO/TELEPHONE POLE
POLE-TELEPHONE
POLE WITH PILASTER
SIGN POST
STAND PIPE
TREE - DECIDUOUS
VALVE - GAS
VALVE - WATER
VAULT
TREE DRIPLINE
K
LEGEND
CLASS 'A'LOADING
CLASS 'A'LOADING
CLASS 'B'LOADING
CLASS 'B'LOADING
47.57 M156'-0 3/4"
36.5
7 M
119'
-11
5/8"
2.08 M6'-9 7/8"
3.10 M10'-1 7/8"
1.67
M5'
-5 3
/4"
2.69
M8'
-9 7
/8"
N
Reliance Properties Ltd.Suite 305 111 Water Street Vancouver, British ColumbiaCanada, V6B 1A7 Tel: 604.683.2404
Client
Key Plan
Project No.
Scale
Drawn By
Issue Date:
© 2019 KOHN PEDERSEN FOX ASSOCIATES PC. All rights reserved.
Kohn Pedersen Fox Associates PCArchitects & Planning Consultants11 West 42nd StreetNew York, New York 10036TEL: 212.977.6500 FAX: 212.956.2526
Architect
Revision
Chris Dikeakos Architects Inc.212 - 3989 Henning Drive, Burnaby, British ColumbiaCanada V5C 6N5Tel: 604. 291.2660
Record Architect
1/16" = 1'-0"
10/3
0/20
19 6
:56:
14 P
M\\k
pfny
-isi0
1\H
omeD
irect
orie
s\ac
ooke
\My
Doc
umen
ts\2
853_
ARC
H_K
PF_a
cook
e(R
ecov
ery)
.rvt
One Vancouver601 W Pender StVancouver, BC V6B 6H4, Canada
10/29/19
SITE PLAN
A-006
Author
2853
A-00
6SI
TE P
LAN
No. Description Date
W. PENDER ST.
GRA
NV
ILLE
ST.
ALLEY OOP
SEYM
OU
R ST
.
W PENDER ST
GR
AN
VILL
E ST
ALLEY OOP
SEYM
OU
R S
T
ROGERSBUILDING
JUNCTION BOX
KIOSK
LAMP STANDARD
MANHOLE
MANHOLE - ELECTRICAL
MANHOLE - SANITARY
PARKING METER
POLE - HYDRO/TELEPHONE POLE
POLE-TELEPHONE
POLE WITH PILASTER
SIGN POST
STAND PIPE
TREE - DECIDUOUS
VALVE - GAS
VALVE - WATER
VAULT
TREE DRIPLINE
K
LEGEND
CLASS 'A'LOADING
CLASS 'A'LOADING
CLASS 'B'LOADING
CLASS 'B'LOADING
47.57 M156'-0 3/4"
36.5
7 M
119'
-11
5/8"
2.08 M6'-9 7/8"
3.10 M10'-1 7/8"
1.67
M5'
-5 3
/4"
2.69
M8'
-9 7
/8"
N
Reliance Properties Ltd.Suite 305 111 Water Street Vancouver, British ColumbiaCanada, V6B 1A7 Tel: 604.683.2404
Client
Key Plan
Project No.
Scale
Drawn By
Issue Date:
© 2019 KOHN PEDERSEN FOX ASSOCIATES PC. All rights reserved.
Kohn Pedersen Fox Associates PCArchitects & Planning Consultants11 West 42nd StreetNew York, New York 10036TEL: 212.977.6500 FAX: 212.956.2526
Architect
Revision
Chris Dikeakos Architects Inc.212 - 3989 Henning Drive, Burnaby, British ColumbiaCanada V5C 6N5Tel: 604. 291.2660
Record Architect
1/16" = 1'-0"
10/3
0/20
19 6
:56:
14 P
M\\k
pfny
-isi0
1\H
omeD
irect
orie
s\ac
ooke
\My
Doc
umen
ts\2
853_
ARC
H_K
PF_a
cook
e(R
ecov
ery)
.rvt
One Vancouver601 W Pender StVancouver, BC V6B 6H4, Canada
10/29/19
SITE PLAN
A-006
Author
2853
A-00
6SI
TE P
LAN
No. Description Date
601 WEST PENDERRezoning Application Booklet
2019.11.01 30
Site Survey
601 WEST PENDERRezoning Application Booklet
2019.11.01 16
Setbacks
DAT
E: 2
018-
03-2
7, 1
4:24
FI
LE: N
:\Pro
ject
s\35
00 S
erie
s\03
554-
00 R
elia
nce
433
Seym
our S
treet
\10.
0 D
RAW
ING
S\10
.1 C
ivil
3D F
iles\
0355
4-00
-V-0
1-R
0.dw
g
ALL DIMENSIONS ARE IN METRES
Rev.
Drawing No.
DES
TRO
Y AL
L PR
INTS
BEA
RIN
G P
REV
IOU
S R
EVIS
ION
Approved Sealed
Project Number
McE
lhan
ney
ANSI
D -
15-0
5-22
RELIANCE PROPERTIES305-111 WATER STREET VANCOUVER BC V6B 1A7
TOPOGRAPHIC SURVEY PLAN OFLOT B (EXPLANATORY PLAN 9806)
BLOCK 23 DISTRICT LOT 541 PLAN 210PID: 015-612-694
433 SEYMOUR STREET, VANCOUVER 0
0 61:150
NOTES:
1. LOCAL GROUND COORDINATES ARE DERIVED FROM OBSERVATIONS TO CITY OFVANCOUVER CONTROL MARKER V-3788. TO CONVERT TO UTM ZONE 10 (NAD83 CSRS)
FIRST APPLY THE FOLLOWING SHIFT:NORTHING=+5,400,000EASTING=+400,000
THEN, MULTIPLY BY THE COMBINED SCALE FACTOR OF 0.99966003 AROUND MON V-3788
2. ELEVATIONS ARE IN METRES AND ARE REFERRED TO GEODETIC DATUM CVD28GVRD USINGMONUMENT V-3788, ELEVATION=22.419 METRES.
3. THIS PLAN REPRESENTS FIELD SURVEY CONDUCTED ON MARCH 21 & 26, 2018.
4. CONTOUR INTERVAL IS 0.5m.
5. PARCEL DIMENSIONS ARE DERIVED FROM PLAN BCP27498 AND LIMITED FIELD TIES.
6. THIS PROPERTY IS SUBJECT TO EASEMENT AND INDEMNITY AGREEMENT 483312M
ORIGINAL DWG SIZE: ANSI D (22" x 34")
Suite 200858 Beatty StreetVancouver BCCanada V6B 1C1Tel 604 683 8521
v
K
JUNCTION BOX
KIOSK
LAMP STANDARD
MANHOLE
MANHOLE - ELECTRICAL
MANHOLE - SANITARY
PARKING METER
POLE - HYDRO/TELEPHONE POLE
POLE - TELEPHONE
POLE WITH PILASTER
SIGN POST
STAND PIPE
TREE - DECIDUOUS
VALVE - GAS
VALVE - WATER
VAULT
LEGEND
TREE DRIPLINE
119’-10”36.5 M
156’-0”47.4 M
SITE AREA:18,705 SF1738 SM *
*
* Dimensions Rounded to Nearest Inch
FACE OF BUILDING SETBACKS
18’-0”5.5M
18’-0”5.5M
601 WEST PENDERRezoning Application Booklet
2019.11.01 17