3
Site Plan ROGERS BUILDING RICAL ARY CLASS 'A' LOADING CLASS 'A' LOADING CLASS 'B' LOADING CLASS 'B' LOADING 47.57 M 156'-0 3/4" 36.57 M 119'-11 5/8" 2.08 M 6'-9 7/8" 3.10 M 10'-1 7/8" 1.67 M 5'-5 3/4" 2.69 M 8'-9 7/8" W. PENDER ST. GRANVILLE ST. ALLEY OOP SEYMOUR ST. JUNCTION BOX KIOSK LAMP STANDARD MANHOLE MANHOLE - ELECTRICAL MANHOLE - SANITARY PARKING METER POLE - HYDRO/TELEPHONE POLE POLE-TELEPHONE POLE WITH PILASTER SIGN POST STAND PIPE TREE - DECIDUOUS VALVE - GAS VALVE - WATER VAULT TREE DRIPLINE K LEGEND 601 WEST PENDER Rezoning Application Booklet 2019.11.01 30

Client Architect Site Plan - Vancouver · 2019. 11. 13. · cuments\2853_ARCH_KPF_acooke(Recovery).rvt One Vancouver 601 W Pender St Vancouver, BC V6B 6H4, Canada 10/29/19 SITE PLAN

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Client Architect Site Plan - Vancouver · 2019. 11. 13. · cuments\2853_ARCH_KPF_acooke(Recovery).rvt One Vancouver 601 W Pender St Vancouver, BC V6B 6H4, Canada 10/29/19 SITE PLAN

Site Plan

W PENDER ST

GR

AN

VILL

E ST

ALLEY OOP

SEYM

OU

R S

T

ROGERSBUILDING

JUNCTION BOX

KIOSK

LAMP STANDARD

MANHOLE

MANHOLE - ELECTRICAL

MANHOLE - SANITARY

PARKING METER

POLE - HYDRO/TELEPHONE POLE

POLE-TELEPHONE

POLE WITH PILASTER

SIGN POST

STAND PIPE

TREE - DECIDUOUS

VALVE - GAS

VALVE - WATER

VAULT

TREE DRIPLINE

K

LEGEND

CLASS 'A'LOADING

CLASS 'A'LOADING

CLASS 'B'LOADING

CLASS 'B'LOADING

47.57 M156'-0 3/4"

36.5

7 M

119'

-11

5/8"

2.08 M6'-9 7/8"

3.10 M10'-1 7/8"

1.67

M5'

-5 3

/4"

2.69

M8'

-9 7

/8"

N

Reliance Properties Ltd.Suite 305 111 Water Street Vancouver, British ColumbiaCanada, V6B 1A7 Tel: 604.683.2404

Client

Key Plan

Project No.

Scale

Drawn By

Issue Date:

© 2019 KOHN PEDERSEN FOX ASSOCIATES PC. All rights reserved.

Kohn Pedersen Fox Associates PCArchitects & Planning Consultants11 West 42nd StreetNew York, New York 10036TEL: 212.977.6500 FAX: 212.956.2526

Architect

Revision

Chris Dikeakos Architects Inc.212 - 3989 Henning Drive, Burnaby, British ColumbiaCanada V5C 6N5Tel: 604. 291.2660

Record Architect

1/16" = 1'-0"

10/3

0/20

19 6

:56:

14 P

M\\k

pfny

-isi0

1\H

omeD

irect

orie

s\ac

ooke

\My

Doc

umen

ts\2

853_

ARC

H_K

PF_a

cook

e(R

ecov

ery)

.rvt

One Vancouver601 W Pender StVancouver, BC V6B 6H4, Canada

10/29/19

SITE PLAN

A-006

Author

2853

A-00

6SI

TE P

LAN

No. Description Date

W. PENDER ST.

GRA

NV

ILLE

ST.

ALLEY OOP

SEYM

OU

R ST

.

W PENDER ST

GR

AN

VILL

E ST

ALLEY OOP

SEYM

OU

R S

T

ROGERSBUILDING

JUNCTION BOX

KIOSK

LAMP STANDARD

MANHOLE

MANHOLE - ELECTRICAL

MANHOLE - SANITARY

PARKING METER

POLE - HYDRO/TELEPHONE POLE

POLE-TELEPHONE

POLE WITH PILASTER

SIGN POST

STAND PIPE

TREE - DECIDUOUS

VALVE - GAS

VALVE - WATER

VAULT

TREE DRIPLINE

K

LEGEND

CLASS 'A'LOADING

CLASS 'A'LOADING

CLASS 'B'LOADING

CLASS 'B'LOADING

47.57 M156'-0 3/4"

36.5

7 M

119'

-11

5/8"

2.08 M6'-9 7/8"

3.10 M10'-1 7/8"

1.67

M5'

-5 3

/4"

2.69

M8'

-9 7

/8"

N

Reliance Properties Ltd.Suite 305 111 Water Street Vancouver, British ColumbiaCanada, V6B 1A7 Tel: 604.683.2404

Client

Key Plan

Project No.

Scale

Drawn By

Issue Date:

© 2019 KOHN PEDERSEN FOX ASSOCIATES PC. All rights reserved.

Kohn Pedersen Fox Associates PCArchitects & Planning Consultants11 West 42nd StreetNew York, New York 10036TEL: 212.977.6500 FAX: 212.956.2526

Architect

Revision

Chris Dikeakos Architects Inc.212 - 3989 Henning Drive, Burnaby, British ColumbiaCanada V5C 6N5Tel: 604. 291.2660

Record Architect

1/16" = 1'-0"

10/3

0/20

19 6

:56:

14 P

M\\k

pfny

-isi0

1\H

omeD

irect

orie

s\ac

ooke

\My

Doc

umen

ts\2

853_

ARC

H_K

PF_a

cook

e(R

ecov

ery)

.rvt

One Vancouver601 W Pender StVancouver, BC V6B 6H4, Canada

10/29/19

SITE PLAN

A-006

Author

2853

A-00

6SI

TE P

LAN

No. Description Date

601 WEST PENDERRezoning Application Booklet

2019.11.01 30

Page 2: Client Architect Site Plan - Vancouver · 2019. 11. 13. · cuments\2853_ARCH_KPF_acooke(Recovery).rvt One Vancouver 601 W Pender St Vancouver, BC V6B 6H4, Canada 10/29/19 SITE PLAN

Site Survey

601 WEST PENDERRezoning Application Booklet

2019.11.01 16

Page 3: Client Architect Site Plan - Vancouver · 2019. 11. 13. · cuments\2853_ARCH_KPF_acooke(Recovery).rvt One Vancouver 601 W Pender St Vancouver, BC V6B 6H4, Canada 10/29/19 SITE PLAN

Setbacks

DAT

E: 2

018-

03-2

7, 1

4:24

FI

LE: N

:\Pro

ject

s\35

00 S

erie

s\03

554-

00 R

elia

nce

433

Seym

our S

treet

\10.

0 D

RAW

ING

S\10

.1 C

ivil

3D F

iles\

0355

4-00

-V-0

1-R

0.dw

g

ALL DIMENSIONS ARE IN METRES

Rev.

Drawing No.

DES

TRO

Y AL

L PR

INTS

BEA

RIN

G P

REV

IOU

S R

EVIS

ION

Approved Sealed

Project Number

McE

lhan

ney

ANSI

D -

15-0

5-22

RELIANCE PROPERTIES305-111 WATER STREET VANCOUVER BC V6B 1A7

TOPOGRAPHIC SURVEY PLAN OFLOT B (EXPLANATORY PLAN 9806)

BLOCK 23 DISTRICT LOT 541 PLAN 210PID: 015-612-694

433 SEYMOUR STREET, VANCOUVER 0

0 61:150

NOTES:

1. LOCAL GROUND COORDINATES ARE DERIVED FROM OBSERVATIONS TO CITY OFVANCOUVER CONTROL MARKER V-3788. TO CONVERT TO UTM ZONE 10 (NAD83 CSRS)

FIRST APPLY THE FOLLOWING SHIFT:NORTHING=+5,400,000EASTING=+400,000

THEN, MULTIPLY BY THE COMBINED SCALE FACTOR OF 0.99966003 AROUND MON V-3788

2. ELEVATIONS ARE IN METRES AND ARE REFERRED TO GEODETIC DATUM CVD28GVRD USINGMONUMENT V-3788, ELEVATION=22.419 METRES.

3. THIS PLAN REPRESENTS FIELD SURVEY CONDUCTED ON MARCH 21 & 26, 2018.

4. CONTOUR INTERVAL IS 0.5m.

5. PARCEL DIMENSIONS ARE DERIVED FROM PLAN BCP27498 AND LIMITED FIELD TIES.

6. THIS PROPERTY IS SUBJECT TO EASEMENT AND INDEMNITY AGREEMENT 483312M

ORIGINAL DWG SIZE: ANSI D (22" x 34")

Suite 200858 Beatty StreetVancouver BCCanada V6B 1C1Tel 604 683 8521

v

K

JUNCTION BOX

KIOSK

LAMP STANDARD

MANHOLE

MANHOLE - ELECTRICAL

MANHOLE - SANITARY

PARKING METER

POLE - HYDRO/TELEPHONE POLE

POLE - TELEPHONE

POLE WITH PILASTER

SIGN POST

STAND PIPE

TREE - DECIDUOUS

VALVE - GAS

VALVE - WATER

VAULT

LEGEND

TREE DRIPLINE

119’-10”36.5 M

156’-0”47.4 M

SITE AREA:18,705 SF1738 SM *

*

* Dimensions Rounded to Nearest Inch

FACE OF BUILDING SETBACKS

18’-0”5.5M

18’-0”5.5M

601 WEST PENDERRezoning Application Booklet

2019.11.01 17