G E P / G E P S Expander Plate
S E R I E S
Product Listings
• ANSI/UL1638Listed• CSFM:7300-0569:147
Product Compliance• NFPA72• IBC/IFC/IRC• City&StateOrdinances/Laws/ Regulations• QualityManagementSystemis certifiedto:ISO9001:2008
Standard Features• NominalVoltage24VDC• Lenscolorsavailable:amber,blue,greenandred• Amberlensmodelshavefieldselectablecandelaoptions:15,30,60,75,110• Blue,greenandredlensmodelsarefixed15/75candela• GEPdimension:10.8”(27.5cm)highx6.6”(16.8cm)widex2.8”(7.15cm)deep• GEPSdimension:11.5”(29.3cm)highx7.26”(18.45cm)widex 5.04”(12.8cm)deep• ALERTtextonallunits• Wallmounttoastandard4”(10.16cm)squarex2.125”(5.4cm)deepbackbox• GEPScanaccommodate1/2and3/4conduit• Screwterminals,separatein/outwiring(12-18gauge)• UseinconjunctionwithGentexspeakerorwallmountspeaker/strobe(SOLD SEPARATELY)• TosynchronizeusetheGentexAVSMControlModule• Wirestripguide• Faceplateavailableinoff-white• Xenonstrobemaintainsconstantflashrateoforat1Hz
Colored Lens Expander Plate Strobe SeriesApplicationsTheGentexGEPandGEPSSeriesisawallmountexpanderplatewithaqualitycoloredlensstrobetobeusedinconjunctionwithaGentexspeakerorwallmountspeaker/strobeallowingtheabilitytomountmultiplestrobesonasingleelectricalbox.Applicationsincludeemergencycommunication,severeweather,evacuation,emergencyresponseandmanymore.
TheGEPSeriesistobeusedinflushmountapplicationsandtheGEPSSeriesistobeusedinsurfacemountapplications.TheGEPandGEPSSeriesstrobesaredesignedtobeusedona24VDCsystemandareavailableinamber,blue,greenandredlenscolors.Theamberlensunitsareprovidedwithaturndialforfieldselectablecandelaoptions.Theblue,greenandredlensunitsareavailableinafixed15/75candelaoption.ThestrobescanbesynchronizedbyusingtheGentexAVSMControlModule,aswellasFACP’sorpowersuppliesthatincludetheGentexSynchronizationProtocol.AllunitsfeatureALERTtextonthelens.
TheGEPandGEPSSeriesareconstructedofhighimpacttexturedplastic.TheSeriesiswarrantedfor3yearsfromthedateofpurchaseandareANSI/UL1638listed.TheamberlensunitsadditionallycomplywiththelightoutputdispersionrequirementsofANSI/UL1971forwallmountapplicationswithameasuredcandelaratingthatisequaltothecandelalistedontheproduct.Noderatingwasrequired.
Lens available in Amber,Blue, Green and Red Colors
GEPGEPS
Model Number
Part Number
Lens Color
Nominal Voltage Candela(s)
GEPA 904-0510-002 Amber 24VDC 15,30,60,75,110
GEPB 904-0511-002 Blue 24VDC Fixed15/75
GEPG 904-0512-002 Green 24VDC Fixed15/75
GEPR 904-0513-002 Red 24VDC Fixed15/75
GEP/GEPS Blue, Green and Red Lens Strobe Current Ratings
Fixed 15/75* Candela Strobe
Lens Color UL Max.1 Operating Current (mA)
Blue 280
Green 360
Red 397
Amber Lens Strobe Candela Ratings
Use with GEPA and GEPAS
CandelaANSI/UL 1638
On-Axis Candela Rating
ANSI/UL 1971 Measured Candela Rating, Wall Mount
15 15 15
30 30 30
60 60 60
75 75 75
110 110 110
GEP/GEPS Amber Lens Strobe Current Ratings
Candela UL Max.1 Operating Current (mA)
15 78
30 96
60 137
75 180
110 224
NOtICE:PerNFPA72,coloredstrobesaretobelistedtoANSI/UL1638.ANSI/UL1971isnotapplicabletocoloredlensdevicesusedinemergencycommunicationinstallations.However,thelistedreadingswereobtainedusingthelightoutputdispersionmeasurementrequirementsunderANSI/UL1971.
GEP Series Flush Mount Expander Plate
GEPS Series Surface Mount Expander Plate Model
NumberPart
NumberLens Color
Nominal Voltage Candela(s)
GEPAS 904-0514-002 Amber 24VDC 15,30,60,75,110
GEPBS 904-0515-002 Blue 24VDC Fixed15/75
GEPGS 904-0516-002 Green 24VDC Fixed15/75
GEPRS 904-0517-002 Red 24VDC Fixed15/75
Model Designations:• Allmodelsaredesignedforwallmountapplications• Allmodelsavailableinwhitefaceplate• AllmodelsincludeALERTtext LensColors: A=Amber B=Blue G=Green R=Red
NOtES:• Operatingtemperature32oto120oF(0oto49oC). TheGEP/GEPSSeriesisnotlistedforoutdoor use.• FornominalandpeakcurrentacrossANSI/UL regulatedvoltagerangeforfilteredDCpowerand unfiltered(FWR(FullWaveRectified))power,see installationmanual.• Gentexdoesnotrecommendusingacoded orpulsingsignalingcircuitwithanyofourstrobe products(seeTechnicalBulletin014).• TheGEP/GEPSSeriesisnottobeusedasa visualpublicmodealarmnotificationappliance.1 RMScurrentratingsareperANSI/ULaverage RMSmethod.ANSI/ULmaxcurrentrating isthemaximumRMScurrentwithinthelisted voltagerange(16-33VDCfor24VDCunits). ForstrobestheULmaxcurrentisusuallyat theminimumlistedvoltage(16VDCfor24VDC units).ForunfilteredFWRratings,see installationmanual.
* TheGEPB,GEPG,GEPR,GEPBS,GEPGS,GEPRS hasafixedcandelaratingof15/75perANSI/UL1638.
Candela Selection: GEPA and GEPAS Only
Adjustintensitybyinsertingsmallflatbladetoturndial.Displayednumberwillindicateselectedcandela.
Additional Mounting Notes:
• Attachspeakerorspeaker/strobeusing themountingring• Levellineistoaidinalignmentduring installation• Includeswirestripguide• Includesfourbaselocationsfor additionalscrewsupport,ifneeded.
Installation GEP Flush Mount Expander Plate Mounting Ring with Key Location
Installation GEPS Surface Mount Expander Plate
ImportantNotice:
ThesematerialshavebeenpreparedbyGentexCorporation(“Gentex”)forinformationalpurposesonly,arenecessarilysummary,andarenotpurportedtoserveaslegaladviceandshouldnotbeusedassuch.Gentexmakesnorepresentationsandwarranties,expressorimplied,thatthesematerialsarecompleteandaccurate,up-to-date,orincompliancewithallrelevantlocal,stateandfederallaws,regulationsandrules.Thematerialsdonotaddressalllegalconsiderationsasthereisinevitableuncertaintyregardinginterpretationoflaws,regulationsandrulesandtheapplicationofsuchlaws,regulationsandrulestoparticularfactpatterns.Eachperson’sactivitiescandifferentlyaffecttheobligationsthatexistunderapplicablelaws,regulationsorrules.Therefore,thesematerialsshouldbeusedonlyforinformationalpurposesandshouldnotbeusedasasubstituteforseekingprofessionallegaladvice.Gentexwillnotberesponsibleforanyactionorfailuretoactinrelianceupontheinformationcontainedinthismaterial.
GEP050113-AAA
G E P / G E P S Expander Plate
S E R I E S
END OF LINERESISTOR
+_
+_
END OF LINERESISTOR
+ _ + _
+_
END OF LINERESISTOR
+ _
TO NEXT APPLIANCE
TO NEXT APPLIANCE
TO NEXT APPLIANCE
FROM LAST APPLIANCE
FROM LAST APPLIANCE
FROM LAST APPLIANCE
SPEAKERSTROBE(OPTIONAL)
STROBE
SPEAKER25 OR 70.7 VRMs
SOURCE
SOURCE
STROBE24 VDC POWER
SOURCE
GENTEX GEP24 VDC POWER
Wiring Diagram
Architect & Engineering Specifications TheexpanderplateshallbeGentexGEPorGEPSColoredLensExpanderPlateorapprovedequivalentandshallbelistedbyUnderwritersLaboratories,Inc.perANSI/UL1638andtheamberlensproductshallhavecompliancewiththepolardispersionrequirementsofANSI/UL1971.TheGEPorGEPSshallalsobelistedwiththeCaliforniaStateFireMarshal(CSFM)andcomplywithalllocal,stateandfederalfirealarmcodes/standards.Thevisualsignalshallhaveaminimum1Hzflashrateregardlessofinputvoltage.Theunitshallhaveaninputvoltagerangeof16-33voltswitheitherdirectcurrentorfullwaverectifiedpowerfor24voltmodels.Allfieldwiringconnectionsshallbemadeviaseparatein-outterminalconnections.
• Allstrobesaredesignedtoflashasspecifiedwithcontinuousappliedvoltage.Strobesshouldnotbeusedoncodedorpulsing signalingcircuits.However,useoftheGentexAVSMcontrolmoduleorGentexsynchronizationprotocolispermittedto synchronizethestrobe,hornand/ormutethehorn.SeeTechnicalBulletin014foradditionalinformation.• FOR SYNCHRONIZAtION WIRING INFORMAtION, REFERENCE AVSM CONtROL MODULE DAtA SHEEt (551-0031) AND/OR AVSM CONtROL MODULE MANUAL (550-0284) FOR SYNCHRONIZAtION MODULE WIRING DIAGRAMS. AVSM CONtROL MODULE DAtA SHEEt AND MANUAL CAN BE OBtAINED At HttP://WWW.GENtEx.COM OR CALL GENtEx CORPORAtION At 1-800-436-8391.
*MAX.WIREDISTANCE(INFEET)= XWIRECONDUCTIVITY(STROBEONLY)PANELVOLTAGE-DEVICEMINIMUMVOLTAGETOTALCURRENTDRAW
* INCLUDESWIRETOANDFROMAPPLIANCE.ASSUMESALLAPPLIANCES AREATTHEENDOFWIRERUN(WORSTCASE).NOTICE:APPLIESONLY TOREGULATEDSUPPLIES.
WIRECONDUCTIVITY18AWG 6016AWG 9514AWG 15312AWG 244
NOTICE:SPEAKERORSPEAKER/STROBEUSEDWITHGEPORGEPSMUSTBEORDEREDSEPARATELY.
CAUTION:DONOTUSELOOPEDWIREUNDERTERMINALS.BREAKWIRERUNTOPROVIDESUPERVISIONOFCONNECTION.
GEPSeries12unitspercarton12poundspercarton
GEPSSeries6unitspercarton9poundspercarton