32
REFER OR OR CHOSE AN OPTION MOUNTING LOCATION: FLUSH WALL CROSS CONNECT POINT CROSS CONNECT BY OTHERS TYPICAL CABLE TRAY WIDTH AS NOTED (END VIEW) TYPICAL CABLE RUNWAY WIDTH AS NOTED MOUNT 7'-0" TO BOTTOM OF STRINGERS UON (END VIEW) FREESTANDING EQUIPMENT RACK AND VERTICAL CABLE MANAGER (FRONT ELEVATION VIEW) 19" WIDE UON FREESTANDING EQUIPMENT RACK WITH VERTICAL WIRE MANAGER (PLAN VIEW) 19" WIDE UON TYPICAL VERTICAL CABLE RUNWAY SECTION WIDTH AS NOTED (ELEVATION VIEW) 2 RACK UNIT 48 PORT PATCH PANEL (ELEVATION VIEW) FIBER OPTIC SLACK STORAGE BOX (PLAN VIEW) FIBER OPTIC SLACK STORAGE BOX (ELEVATION VIEW) TELECOMMUNICATIONS GROUNDING BUSBAR PROVIDED BY OTHERS (PLAN VIEW) TELECOMMUNICATIONS GROUNDING BUSBAR PROVIDED BY OTHERS (ELEVATION VIEW) RACK MOUNTED GROUNDING BAR (ELEVATION VIEW) RACK MOUNTED POWER RECEPTACLE (ELEVATION VIEW) PROTECTION PANEL (PLAN VIEW) WIRING TROUGH WITH LEGS (ELEVATION VIEW) MOUNTING LOCATION: RACEWAY WORKSTATION OUTLETS CONFIGURATION: AS INDICATED BY NO. CONFIGURATION: AS INDICATED BY NO. WORKSTATION OUTLETS MOUNTING LOCATION: CASEWORK OR ABOVE BACKSPLASH - FLUSH ABBREVIATIONS TECHNOLOGY SYMBOLS AND ABBREVIATIONS NEW CONNECTION TO EXISTING NOTE: REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS FOR DEVICES. REFERENCE SYMBOLS EQUIPMENT NAME AND NUMBER KEYNOTE NUMBER REVISION NUMBER CONSTRUCTION BULLETIN NUMBER DETAIL REFERENCE TOP DESIGNATES DETAIL NUMBER BOTTOM DESIGNATES SHEET NUMBER BOTTOM DESIGNATES SHEET NUMBER TOP DESIGNATES SECTION NUMBER SECTION REFERENCE GENERAL REFERENCE DESIGNATES SHEET NUMBER ELEVATION SYMBOL LAB EQUIPMENT NUMBER CROSS CONNECT POINT 2 RACK UNIT HORIZONTAL CABLE MANAGER (ELEVATION VIEW) 6-STRAND SINGLE-MODE PANEL WITH (3) DUPLEX COUPLINGS MOUNTING LOCATION: FLUSH WALL WORKSTATION OUTLETS CONFIGURATION: AS INDICATED BY NO. WALL TELEPHONE OUTLET TECHNOLOGY SERVICES 6-STRAND MULTI-MODE PANEL WITH (3) DUPLEX COUPLINGS RACK MOUNTED FIBER OPTIC PATCH PANEL MOUNTING LOCATION: FLUSH FLOOR WORKSTATION OUTLETS - FLOOR MOUNTED CONFIGURATION: 2 DATA CONFIGURATION: AS INDICATED BY NO. WORKSTATION OUTLETS MOUNTING LOCATION: SURFACE WALL CONFIGURATION: AS INDICATED BY NO. WORKSTATION OUTLETS - CEILING MOUNTED MOUNTING LOCATION: FLUSH CEILING CCTV OUTLETS - CEILING MOUNTED CONFIGURATION: 1 DATA WALL TELEPHONE OUTLET MOUNTING LOCATION: SURFACE WALL MOUNTING HEIGHT: 4'-0" AFF MOUNTING HEIGHT: 4'-0" AFF MOUNTING HEIGHT: 1'-6" AFF MOUNTING HEIGHT: 1'-6" AFF MOUNTING HEIGHT: F/FF MOUNTING HEIGHT: F/FC MOUNTING HEIGHT: FIELD VERIFY MOUNTING HEIGHT: FIELD VERIFY MOUNTING HEIGHT: MATCH ELECTRICAL CONFIGURATION: 2 DATA WIRELESS ACCESS POINT MOUNTING HEIGHT: FIELD VERIFY CONFIGURATION: AS INDICATED BY NO. WORKSTATION OUTLETS MOUNTING LOCATION: CASEWORK OR ABOVE BACKSPLASH - SURFACE MOUNTING HEIGHT: FIELD VERIFY CONFIGURATION: 1 VOICE CONFIGURATION: 1 VOICE # = QUANTITY OF CABLES TERMINATED CONFIGURATION: MOUNTING HEIGHTS AS INDICATED BELOW UNLESS OTHERWISE NOTED ON DRAWINGS 12-STRAND SINGLE-MODE PANEL WITH (6) DUPLEX COUPLINGS 12-STRAND MULTI-MODE PANEL WITH (6) DUPLEX COUPLINGS DET # SHT # NAME # # SHT # # # SHT # # W W # # # # # # # AP M M M M M M S S S S S S # WIRING TROUGH WITH LEGS (PLAN VIEW) S S S S S S M M M M M M SC MOUNTING LOCATION: 6" ABOVE CEILING HEIGHT MOUNTING LOCATION: 6" ABOVE CEILING HEIGHT SECURITY CARD READER MOUNTING LOCATION: WALL MOUNTING HEIGHT: 42" A.F.F. CLOSED CIRCUIT SECURITY CAMERA MOUNTING LOCATION: CEILING MOUNTING HEIGHT: SURFACE CEILING #-## = FLOOR-SEQUENTIAL NUMBER DOOR POSITION SWITCH MOUNTING LOCATION: WALL MOUNTING HEIGHT: AS NOTED CONTROL PANEL POWER SUPPLY CB PS DC CR CLOSED CIRCUIT SECURITY CAMERA MOUNTING LOCATION: WALL MOUNTING HEIGHT: AS NOTED DOOR TAG XXXX #-## = FLOOR-SEQUENTIAL NUMBER #-## #-## VIDEO INTERCOM MOUNTING LOCATION: WALL MOUNTING HEIGHT: AS NOTED VI CARD READER - KEYPAD COMBO MOUNTING LOCATION: WALL MOUNTING HEIGHT: 42" A.F.F. CR-KP ABOVE CEILING/ALTERNATING CURRENT ACCESS CONTROL PANEL ACOUSTICAL CEILING TILE AUTOMATIC DOOR OPENER ABOVE FINISHED FLOOR ASSISTIVE LISTENING SYSTEM ALTERNATE ARCHITECTURAL ABOVE SUSPENDED CEILING AUTOMATIC AMERICAN WIRE GAUGE BELOW FINISH CEILING BELOW FLOOR LEVEL BUILDING CONDUIT CLOSED CIRCUIT TELEVISION CIRCUIT CIRCUIT BREAKER CEILING CONTRACTOR CORRIDOR CABLE TRAY DIRECT CURRENT DEDICATED DETAIL DIAMETER DOWN DIGITAL VIDEO RECORDER EMPTY CONDUIT/ELECTRICAL CONTRACTOR ENTRANCE FACILITY EQUIPMENT GROUND ENGINE GENERATOR SET EQUIPMENT INTERMEDIATE DISTRIBUTION FACILITY ELECTRIC/ELECTRICAL EMERGENCY ELECTROMAGNETIC INTERFERENCE ELECTRICAL METALLIC TUBING EQUIPMENT EQUIPMENT ROOM EXISTING TO REMAIN FLUSH WITH FINISHED CEILING FLUSH WITH FINISHED FLOOR FLUSH WITH FINISHED WALL FIRE ALARM FIRE ALARM CONTROL PANEL AT FLOOR LINE FLEXIBLE FLOOR FLAME SAFEGUARD CONTROL PANEL GIGABIT INTERFACE CONVERTER GENERAL CONTRACTOR GROUND FAULT CIRCUIT INTERUPTER GROUND GENERATOR GALVANIZED RIGID CONDUIT HIGH VOLTAGE INTERMEDIATE DISTRIBUTION FACILITY INTERMEDIATE METAL CONDUIT AC ACS ACT ADO AFF ALS ALT ARCH ASC AUTO AWG BFC BFL BLDG C CCTV CCT CCT BKR CLG CONTR CORR CT DC DED DET DIA DN DVR EC EF EG EGS EIDF FAC ELEC EMER EMI EMT EQUIP ER ETR F/FC F/FF F/FW FA FACP FL FLEX FLR FSCP GBIC GC GFCI GND GEN GRC HV IDF IMC JUNCTION BOX KILOVOLT KILOVOLT-AMPERES KILOWATTS LOCAL AREA NETWORK LOW VOLTAGE MECHANICAL CONTRACTOR MAIN DISTRIBUTION FACILITY MAIN EQUIPMENT ROOM MAINTENANCE HOLE MULTIMODE MUSIC & PAGE MOUNTED MOUNTING MOUNTING HEIGHT NOT APPLICABLE NOT IN CONTRACT NOT TO SCALE ON CENTER OWNER FURNISHED CONTRACTOR INSTALLED OWNER FURNISHED OWNER INSTALLED PULL BOX/PUSH-BUTTON PRIVATE BRANCH EXCHANGE PLUMBING CONTRACTOR/PHOTOCELL/PERSONAL COMPUTER POWER DISTRIBUTION UNIT POWER FACTOR PHASE PLUMBING PANEL POWER PAN, TILT, ZOOM RECESSED RECEPTACLE RELOCATE REQUIRED RACK UNIT SHEET SIGNAL SIMILAR STANDARD INFORMATION OUTLET SINGLEMODE SPECIFICATION SAFETY SWITCH STATION SWITCH TERMINAL BOX TELEPHONE TO FLOOR ABOVE TO FLOOR BELOW TELECOMMUNICATIONS OUTLET TELECOM ROOM TAMPER SWITCH/TIME SWITCH TELEVISION TRANSIENT VOLTAGE SURGE SUPPRESSION TYPICAL UNDER COUNTER UNDERGROUND UNLESS OTHERWISE NOTED UNINTERRUPTABLE POWER SUPPLY VOLTAGE VOICE OVER INTERNET PROTOCOL WIRE WITH WEATHERPROOF WALL SURFACE WATER TIGHT EXIST TRANSFORMER JB KV KVA KW LAN LV MC MDF MER MH MM MP MTD MTG MTG HGT NA NIC NTS OC OFCI OFOI PB PBX PC PDU PF PH PLBG PNL PWR PTZ REC RECEP REL REQD RU SHT SIG SIM SIO SM SPEC SS STA SW TB TEL TFA TFB TO TR TS TV TVSS TYP UC UG UON UPS V VoIP W W/ WP WS WT X XFMR COLLEGE OF LAKE COUNTY SCIENCE ADDITION AND RENOVATIONS 19351 WEST WASHINGTON STREET, GRAYSLAKE, IL 60030 CDB PROJECT NO. DATE SHEET NO. OF ( )SHEETS 810-056-025 TERRA ENGINEERING, LTD. LARSON ENGINEERING OF ILLINOIS CONSTRUCTION COST SYSTEMS, INC. 1815 SOUTH MEYERS ROAD, SUITE 200 OAKBROOK TERRACE, IL 60181 225 W. OHIO STREET - 4TH FLOOR CHICAGO, IL 60654 1488 BOND STREET, SUITE 100 NAPERVILLE, IL 60563 CIVIL ENGINEER STRUCTURAL ENGINEER COST ESTIMATING PHONE: (312) 467-0123 ext: 230 PHONE: (630) 357-0540 PHONE: (630) 678-0808 CARNOW CONIBEAR 600 W. VAN BUREN - #500 CHICAGO, IL 60607 ASBESTOS ABATEMENT PHONE: (312) 762-2936 Pat Quinn, Governor State of Illinois Illinois Capital Development Board PHONE: (815) 477-4545 MEPFPT ENGINEER ARCHITECT PHONE: (312) 977-2800 DESIGNER (312) 787-4405 REVISIONS CHECKED APPROVED PROJ. MNGR. NOTE: CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AND BE FULLY RESPONSIBLE FOR SAME. DRAWN ARCHITECT'S PROJECT NO. SPF 211001.00 AFFILIATED ENGINEERS, INC. 10 SOUTH LASALLE STREET, SUITE 2700 CHICAGO, IL 60603 LEGAT ARCHITECTS 80 NORTH VIRGINIA STREET, SUITE C CRYSTAL LAKE, IL 60014 BRUBAKER 900 NORTH LAKESHORE DRIVE #2703 CHICAGO, ILLINOIS 60611 100% BID DOCUMENTS dbHMS 303 W. Erie Street - #510 CHICAGO, IL 60654 COMMISSIONING AUTHORITY PHONE: (312) 915-0557 ext. 258 07.21.2014 COM-000 COMMUNICATIONS SYMBOLS & ABBREVIATIONS CH CH KV 07.21.2014 NO. DATE REMARKS

COM-000 · elevation symbol lab equipment number cross connect point 2 rack unit horizontal ... closed circuit security camera cr mounting location: wall mounting height: as noted

  • Upload
    dokhanh

  • View
    221

  • Download
    0

Embed Size (px)

Citation preview

REFER

OR

OR

CHOSE AN OPTION

MOUNTING LOCATION: FLUSH WALL

CROSS CONNECT POINTCROSS CONNECT BYOTHERS

TYPICAL CABLE TRAYWIDTH AS NOTED(END VIEW)

TYPICAL CABLE RUNWAYWIDTH AS NOTEDMOUNT 7'-0" TO BOTTOM OFSTRINGERS UON(END VIEW)

FREESTANDING EQUIPMENT RACKAND VERTICAL CABLE MANAGER(FRONT ELEVATION VIEW)19" WIDE UON

FREESTANDING EQUIPMENT RACKWITH VERTICAL WIRE MANAGER(PLAN VIEW)19" WIDE UON

TYPICAL VERTICAL CABLERUNWAY SECTIONWIDTH AS NOTED(ELEVATION VIEW)

2 RACK UNIT 48 PORTPATCH PANEL(ELEVATION VIEW)

FIBER OPTIC SLACKSTORAGE BOX(PLAN VIEW)

FIBER OPTIC SLACKSTORAGE BOX(ELEVATION VIEW)

TELECOMMUNICATIONSGROUNDING BUSBARPROVIDED BY OTHERS(PLAN VIEW)

TELECOMMUNICATIONSGROUNDING BUSBARPROVIDED BY OTHERS(ELEVATION VIEW)

RACK MOUNTEDGROUNDING BAR(ELEVATION VIEW)

RACK MOUNTEDPOWER RECEPTACLE(ELEVATION VIEW)

PROTECTION PANEL(PLAN VIEW)

WIRING TROUGH WITHLEGS (ELEVATION VIEW)

MOUNTING LOCATION: RACEWAY

WORKSTATION OUTLETSCONFIGURATION: AS INDICATED BY NO.

CONFIGURATION: AS INDICATED BY NO.WORKSTATION OUTLETS

MOUNTING LOCATION: CASEWORK OR ABOVEBACKSPLASH - FLUSH

ABBREVIATIONS

TECHNOLOGY SYMBOLS AND ABBREVIATIONS

NEW CONNECTION TO EXISTING

NOTE: REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS FOR DEVICES.

REFERENCE SYMBOLS

EQUIPMENT NAME AND NUMBER

KEYNOTE NUMBER

REVISION NUMBER

CONSTRUCTION BULLETIN NUMBER

DETAIL REFERENCETOP DESIGNATES DETAIL NUMBERBOTTOM DESIGNATES SHEET NUMBER

BOTTOM DESIGNATES SHEET NUMBERTOP DESIGNATES SECTION NUMBERSECTION REFERENCE

GENERAL REFERENCEDESIGNATES SHEET NUMBER

ELEVATION SYMBOL

LAB EQUIPMENT NUMBER

CROSS CONNECT POINT

2 RACK UNIT HORIZONTALCABLE MANAGER(ELEVATION VIEW)

6-STRAND SINGLE-MODEPANEL WITH (3) DUPLEXCOUPLINGS

MOUNTING LOCATION: FLUSH WALL

WORKSTATION OUTLETSCONFIGURATION: AS INDICATED BY NO.

WALL TELEPHONE OUTLET

TECHNOLOGY SERVICES

6-STRAND MULTI-MODEPANEL WITH (3) DUPLEXCOUPLINGS

RACK MOUNTED FIBER OPTICPATCH PANEL

MOUNTING LOCATION: FLUSH FLOOR

WORKSTATION OUTLETS - FLOOR MOUNTEDCONFIGURATION: 2 DATA

CONFIGURATION: AS INDICATED BY NO.WORKSTATION OUTLETS

MOUNTING LOCATION: SURFACE WALL

CONFIGURATION: AS INDICATED BY NO.WORKSTATION OUTLETS - CEILING MOUNTED

MOUNTING LOCATION: FLUSH CEILING

CCTV OUTLETS - CEILING MOUNTEDCONFIGURATION: 1 DATA

WALL TELEPHONE OUTLET

MOUNTING LOCATION: SURFACE WALL

MOUNTING HEIGHT: 4'-0" AFF

MOUNTING HEIGHT: 4'-0" AFF

MOUNTING HEIGHT: 1'-6" AFF

MOUNTING HEIGHT: 1'-6" AFF

MOUNTING HEIGHT: F/FF

MOUNTING HEIGHT: F/FC

MOUNTING HEIGHT: FIELD VERIFY

MOUNTING HEIGHT: FIELD VERIFY

MOUNTING HEIGHT: MATCH ELECTRICAL

CONFIGURATION: 2 DATAWIRELESS ACCESS POINT

MOUNTING HEIGHT: FIELD VERIFY

CONFIGURATION: AS INDICATED BY NO.WORKSTATION OUTLETS

MOUNTING LOCATION: CASEWORK OR ABOVEBACKSPLASH - SURFACEMOUNTING HEIGHT: FIELD VERIFY

CONFIGURATION: 1 VOICE

CONFIGURATION: 1 VOICE

# = QUANTITY OF CABLES TERMINATEDCONFIGURATION:

MOUNTING HEIGHTS AS INDICATED BELOWUNLESS OTHERWISE NOTED ON DRAWINGS

12-STRAND SINGLE-MODEPANEL WITH (6) DUPLEXCOUPLINGS

12-STRAND MULTI-MODEPANEL WITH (6) DUPLEXCOUPLINGS

DET #

SHT #

NAME#

#

SHT #

#

#

SHT #

#

W

W

#

#

#

#

#

#

#

AP

M

M

M

M

M

M

S

S

S

S

S

S

#

WIRING TROUGH WITHLEGS (PLAN VIEW)

S S S S S S

M M M M M M

SC

MOUNTING LOCATION: 6" ABOVE CEILING HEIGHT

MOUNTING LOCATION: 6" ABOVE CEILING HEIGHT

SECURITY

CARD READERMOUNTING LOCATION: WALLMOUNTING HEIGHT: 42" A.F.F.

CLOSED CIRCUIT SECURITY CAMERAMOUNTING LOCATION: CEILINGMOUNTING HEIGHT: SURFACE CEILING

#-## = FLOOR-SEQUENTIAL NUMBER

DOOR POSITION SWITCHMOUNTING LOCATION: WALLMOUNTING HEIGHT: AS NOTED

CONTROL PANEL POWER SUPPLYCB PS

DC

CRCLOSED CIRCUIT SECURITY CAMERAMOUNTING LOCATION: WALLMOUNTING HEIGHT: AS NOTED

DOOR TAGXXXX

#-## = FLOOR-SEQUENTIAL NUMBER

#-##

#-##

VIDEO INTERCOMMOUNTING LOCATION: WALLMOUNTING HEIGHT: AS NOTED

VI

CARD READER - KEYPAD COMBOMOUNTING LOCATION: WALLMOUNTING HEIGHT: 42" A.F.F.

CR-KP

ABOVE CEILING/ALTERNATING CURRENTACCESS CONTROL PANELACOUSTICAL CEILING TILEAUTOMATIC DOOR OPENERABOVE FINISHED FLOORASSISTIVE LISTENING SYSTEMALTERNATEARCHITECTURALABOVE SUSPENDED CEILINGAUTOMATICAMERICAN WIRE GAUGEBELOW FINISH CEILINGBELOW FLOOR LEVELBUILDINGCONDUITCLOSED CIRCUIT TELEVISIONCIRCUITCIRCUIT BREAKERCEILINGCONTRACTORCORRIDORCABLE TRAYDIRECT CURRENTDEDICATEDDETAILDIAMETERDOWNDIGITAL VIDEO RECORDEREMPTY CONDUIT/ELECTRICAL CONTRACTORENTRANCE FACILITYEQUIPMENT GROUNDENGINE GENERATOR SETEQUIPMENT INTERMEDIATE DISTRIBUTIONFACILITYELECTRIC/ELECTRICALEMERGENCYELECTROMAGNETIC INTERFERENCEELECTRICAL METALLIC TUBINGEQUIPMENTEQUIPMENT ROOMEXISTING TO REMAINFLUSH WITH FINISHED CEILINGFLUSH WITH FINISHED FLOORFLUSH WITH FINISHED WALLFIRE ALARMFIRE ALARM CONTROL PANELAT FLOOR LINEFLEXIBLEFLOORFLAME SAFEGUARD CONTROL PANELGIGABIT INTERFACE CONVERTERGENERAL CONTRACTORGROUND FAULT CIRCUIT INTERUPTERGROUNDGENERATORGALVANIZED RIGID CONDUITHIGH VOLTAGEINTERMEDIATE DISTRIBUTION FACILITYINTERMEDIATE METAL CONDUIT

ACACSACTADOAFFALSALT

ARCHASC

AUTOAWGBFCBFL

BLDGC

CCTVCCT

CCT BKRCLG

CONTRCORR

CTDC

DEDDETDIADN

DVRECEFEG

EGSEIDFFAC

ELECEMER

EMIEMT

EQUIPER

ETRF/FCF/FF

F/FWFA

FACPFL

FLEXFLR

FSCPGBIC

GCGFCIGNDGENGRC

HVIDFIMC

JUNCTION BOXKILOVOLTKILOVOLT-AMPERESKILOWATTSLOCAL AREA NETWORKLOW VOLTAGEMECHANICAL CONTRACTORMAIN DISTRIBUTION FACILITYMAIN EQUIPMENT ROOMMAINTENANCE HOLEMULTIMODEMUSIC & PAGEMOUNTEDMOUNTINGMOUNTING HEIGHTNOT APPLICABLENOT IN CONTRACTNOT TO SCALEON CENTEROWNER FURNISHED CONTRACTOR INSTALLEDOWNER FURNISHED OWNER INSTALLEDPULL BOX/PUSH-BUTTONPRIVATE BRANCH EXCHANGEPLUMBING CONTRACTOR/PHOTOCELL/PERSONAL COMPUTERPOWER DISTRIBUTION UNITPOWER FACTORPHASEPLUMBINGPANELPOWERPAN, TILT, ZOOMRECESSEDRECEPTACLERELOCATEREQUIREDRACK UNITSHEETSIGNALSIMILARSTANDARD INFORMATION OUTLETSINGLEMODESPECIFICATIONSAFETY SWITCHSTATIONSWITCHTERMINAL BOXTELEPHONETO FLOOR ABOVETO FLOOR BELOWTELECOMMUNICATIONS OUTLETTELECOM ROOMTAMPER SWITCH/TIME SWITCHTELEVISIONTRANSIENT VOLTAGE SURGE SUPPRESSIONTYPICALUNDER COUNTERUNDERGROUNDUNLESS OTHERWISE NOTEDUNINTERRUPTABLE POWER SUPPLYVOLTAGEVOICE OVER INTERNET PROTOCOLWIREWITHWEATHERPROOFWALL SURFACEWATER TIGHTEXISTTRANSFORMER

JBKV

KVAKW

LANLV

MCMDFMER

MHMMMP

MTDMTG

MTG HGTNA

NICNTSOC

OFCIOFOI

PBPBX

PCPDU

PFPH

PLBGPNL

PWRPTZREC

RECEPREL

REQDRU

SHTSIGSIMSIOSM

SPECSS

STASWTB

TELTFATFBTOTRTSTV

TVSSTYPUCUG

UONUPS

VVoIP

WW/

WPWSWT

XXFMR

COLLEGE OF LAKE COUNTYSCIENCE ADDITION AND RENOVATIONS

19351 WEST WASHINGTON STREET, GRAYSLAKE, IL 60030

CDB PROJECT NO.

DATE

SHEET NO.

OF ( )SHEETS

810-056-025TERRA ENGINEERING, LTD.

LARSON ENGINEERING OF ILLINOIS

CONSTRUCTION COST SYSTEMS, INC.1815 SOUTH MEYERS ROAD, SUITE 200OAKBROOK TERRACE, IL 60181

225 W. OHIO STREET - 4TH FLOORCHICAGO, IL 60654

1488 BOND STREET, SUITE 100NAPERVILLE, IL 60563

CIVIL ENGINEER

STRUCTURAL ENGINEER

COST ESTIMATING

PHONE: (312) 467-0123ext: 230

PHONE: (630) 357-0540

PHONE: (630) 678-0808

CARNOW CONIBEAR

600 W. VAN BUREN - #500CHICAGO, IL 60607

ASBESTOS ABATEMENT

PHONE: (312) 762-2936

Pat Quinn, GovernorState of Illinois

Illinois Capital Development Board

PHONE: (815) 477-4545

MEPFPT ENGINEER

ARCHITECT

PHONE: (312) 977-2800

DESIGNER(312) 787-4405

REVISIONS

CHECKED APPROVED

PROJ. MNGR.

NOTE: CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AND BE FULLY RESPONSIBLE FOR SAME.

DRAWN

ARCHITECT'S PROJECT NO.

SPF

211001.00

AFFILIATED ENGINEERS, INC.

10 SOUTH LASALLE STREET, SUITE 2700CHICAGO, IL 60603

LEGAT ARCHITECTS

80 NORTH VIRGINIA STREET, SUITE CCRYSTAL LAKE, IL 60014

BRUBAKER

900 NORTH LAKESHORE DRIVE #2703CHICAGO, ILLINOIS 60611

100% BID DOCUMENTS

dbHMS

303 W. Erie Street - #510CHICAGO, IL 60654

COMMISSIONING AUTHORITY

PHONE: (312) 915-0557 ext. 258

07.21.2014

COM-000

COMMUNICATIONS SYMBOLS & ABBREVIATIONS

CHCH

KV

07.21.2014

NO. DATE REMARKS

4n3.2n 5n 6n 8n 9n 10n 11n 12n 13n

C-n

B-n

A-n

2n7n

E-n

A.7-n

2.4n

12.7n 14n

D-n

3n

A.1-n

A.4-n

A.2-n

C.1-n

A.a-n

15n

4n3.2n 5n 6n 8n 9n 10n 11n 12n 13n

C-n

B-n

A-n

2n7n

E-n

A.7-n

2.4n

12.7n

14n

D-n

3n

A.1.7-n

A.4-n

A.2-n

C.1-n

-A.1-n

15n

D.4-n

13.1n8.5n

1.8n1.2n

APPROX LOCATIONOF TEST WELL

BRICK PAVERS

FLAGSTONE WALLHT. VARIES

6"PVC SAN

ROTUNDA WAY

15' COMED EASEMENT PER UNRECORDED DOCUMENT C-4000219

PROPOSED 54' INGRESS AND EGRESS EASEMENT

AS SHOWN ON PLAT OF SURVEY PREPARED

BY MANHARD CONSULTI NG, LTD. AND DATED 11/13/2002

AND DATED 11/13/2002

AV

IDF S-106REFER TO SHEET COM-101A

1

1 1

2 2

KEY PLAN

COLLEGE OF LAKE COUNTYSCIENCE ADDITION AND RENOVATIONS

19351 WEST WASHINGTON STREET, GRAYSLAKE, IL 60030

CDB PROJECT NO.

DATE

SHEET NO.

OF ( )SHEETS

810-056-025TERRA ENGINEERING, LTD.

LARSON ENGINEERING OF ILLINOIS

CONSTRUCTION COST SYSTEMS, INC.1815 SOUTH MEYERS ROAD, SUITE 200OAKBROOK TERRACE, IL 60181

225 W. OHIO STREET - 4TH FLOORCHICAGO, IL 60654

1488 BOND STREET, SUITE 100NAPERVILLE, IL 60563

CIVIL ENGINEER

STRUCTURAL ENGINEER

COST ESTIMATING

PHONE: (312) 467-0123ext: 230

PHONE: (630) 357-0540

PHONE: (630) 678-0808

CARNOW CONIBEAR

600 W. VAN BUREN - #500CHICAGO, IL 60607

ASBESTOS ABATEMENT

PHONE: (312) 762-2936

Pat Quinn, GovernorState of Illinois

Illinois Capital Development Board

PHONE: (815) 477-4545

MEPFPT ENGINEER

ARCHITECT

PHONE: (312) 977-2800

DESIGNER(312) 787-4405

REVISIONS

CHECKED APPROVED

PROJ. MNGR.

NOTE: CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AND BE FULLY RESPONSIBLE FOR SAME.

DRAWN

ARCHITECT'S PROJECT NO.

SPF

211001.00

AFFILIATED ENGINEERS, INC.

10 SOUTH LASALLE STREET, SUITE 2700CHICAGO, IL 60603

LEGAT ARCHITECTS

80 NORTH VIRGINIA STREET, SUITE CCRYSTAL LAKE, IL 60014

BRUBAKER

900 NORTH LAKESHORE DRIVE #2703CHICAGO, ILLINOIS 60611

100% BID DOCUMENTS

dbHMS

303 W. Erie Street - #510CHICAGO, IL 60654

COMMISSIONING AUTHORITY

PHONE: (312) 915-0557 ext. 258

07.21.2014

COM-001

SITE COMMUNICATIONS PLAN

CHCH

KV

07.21.2014

1" = 30'-0"1

SITE COMMUNICATIONS PLAN

SHEET KEYNOTES

1 PROVIDE (1) 1" PVC80 CONDUIT TO IDF S-106.

2 PROVIDE NEMA 3R BACK BOX AND BLANK COVER PLATES FOR FUTURE VEHICLECHARGING STATIONS.

NO. DATE REMARKS

PT

D

PT

D

CH

PTD PTD PTD

VPS

CH

VPS

PTD PTD PTD

CHPTD

PTD PTD

PT

DC

H

VP

S

VP

S

PTD

VP

S

PT

DP

TD

PTD

PTD

PTD

PT

DP

TD

CH CHVPS

VPS

CH CH

A1

C

F.3

H

J

L

1713

16.21615.915.715 15.8

1

M

K

J.8

G

F

E

B1

C1

D1

D

12A

KEY PLAN

MODULE-A

COLLEGE OF LAKE COUNTYSCIENCE ADDITION AND RENOVATIONS

19351 WEST WASHINGTON STREET, GRAYSLAKE, IL 60030

CDB PROJECT NO.

DATE

SHEET NO.

OF ( )SHEETS

810-056-025TERRA ENGINEERING, LTD.

LARSON ENGINEERING OF ILLINOIS

CONSTRUCTION COST SYSTEMS, INC.1815 SOUTH MEYERS ROAD, SUITE 200OAKBROOK TERRACE, IL 60181

225 W. OHIO STREET - 4TH FLOORCHICAGO, IL 60654

1488 BOND STREET, SUITE 100NAPERVILLE, IL 60563

CIVIL ENGINEER

STRUCTURAL ENGINEER

COST ESTIMATING

PHONE: (312) 467-0123ext: 230

PHONE: (630) 357-0540

PHONE: (630) 678-0808

CARNOW CONIBEAR

600 W. VAN BUREN - #500CHICAGO, IL 60607

ASBESTOS ABATEMENT

PHONE: (312) 762-2936

Pat Quinn, GovernorState of Illinois

Illinois Capital Development Board

PHONE: (815) 477-4545

MEPFPT ENGINEER

ARCHITECT

PHONE: (312) 977-2800

DESIGNER(312) 787-4405

REVISIONS

CHECKED APPROVED

PROJ. MNGR.

NOTE: CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AND BE FULLY RESPONSIBLE FOR SAME.

DRAWN

ARCHITECT'S PROJECT NO.

SPF

211001.00

AFFILIATED ENGINEERS, INC.

10 SOUTH LASALLE STREET, SUITE 2700CHICAGO, IL 60603

LEGAT ARCHITECTS

80 NORTH VIRGINIA STREET, SUITE CCRYSTAL LAKE, IL 60014

BRUBAKER

900 NORTH LAKESHORE DRIVE #2703CHICAGO, ILLINOIS 60611

100% BID DOCUMENTS

dbHMS

303 W. Erie Street - #510CHICAGO, IL 60654

COMMISSIONING AUTHORITY

PHONE: (312) 915-0557 ext. 258

07.21.2014

COMD-102B

SECOND FLOOR COMMUNICATIONS DEMO PLAN - MODULE B

CHCH

KV

07.21.2014

0' 2' 4' 8' 16'

1 DISCONNECT AND REMOVE ALL OUTLETS AND HORIZONTAL CABLINGBACK TO SERVING IDF ROOMS.

SHEET KEYED NOTES

GENERAL NOTES

REFER TO SPECIFICATIONS FOR DIRECTIONS REGARDING DEMOLITIONWORK.

AREA OF DEMOLITION SHOWN IS FOR APPROXIMATION PURPOSES ONLY.ELECTRICAL CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGSFOR EXACT AREA OF DEMOLITION.

EQUIPMENT LOCATIONS SHOWN ARE APPROXIMATE AND SHALL BE FIELDVERIFIED.

FURNISH ALL LABOR, MATERIALS AND EQUIPMENT REQUIRED TOCOMPLETE DEMOLITION OF EXISTING ELECTRICAL EQUIPMENT ASSPECIFIED OR INDICATED. DISCONNECT, REMOVE AND RELOCATE ALLITEMS AS REQUIRED TO FACILITATE THE NEW CONSTRUCTION.

ELECTRICAL CONTRACTOR SHALL THOROUGHLY FAMILIARIZE HIMSELFWITH EXISTING ELECTRICAL SYSTEM, WHICH WILL BE AFFECTED BY THEDEMOLITION AND REMODELING WORK.

ELECTRICAL CONTRACTOR SHALL OBTAIN PERMISSION FROM USINGAGENCY'S REPRESENTATIVE TO SHUT OFF SERVICES OR SYSTEM, WHICHMAY AFFECT OTHER AREAS BEYOND THE LIMITS OF THE IMMEDIATEDEMOLITION AREA. SUCH PERMISSION WILL BE GRANTED ONLY AFTERUSING AGENCY'S REPRESENTATIVE IS INFORMED AS TO THE REASON FORAND DURATION OF THE SHUTDOWN AND IS SATISFIED THAT THESHUTDOWN CAN BE MADE WITH AS LITTLE INCONVENIENCE TO OTHERAREAS AS POSSIBLE.

1.

2.

3.

4.

5.

6.

1/8" = 1'-0"1

SECOND FLOOR COMMUNICATIONS DEMOLITION PLAN - MODULE B

NO. DATE REMARKS

VPS PTDSDPTDSD

CH

PT

DP

TD

PT

D

PTDSDPTDSD

PTDSDPTDSD

PTD SDPTDSD

VPS

VPS

PT

D

PT

DP

TD

SD

SD

CH

VP

SM

BV

PS

CH

PT

DS

D

VPS

REF REF

ICE

RE

F

.R

EF

RE

FC

HR

EF

RE

F

RE

F

VPS

1 2.1 42

PQ

R

S

U

V

7 105.75.3

B-n

A-n

A.7-n

A.2-n

A.4-n

RE-5

1

ALTERNATE #E-2

7

ALTERNATE #E-3

T

KEY PLANMOD

ULE

-C

COLLEGE OF LAKE COUNTYSCIENCE ADDITION AND RENOVATIONS

19351 WEST WASHINGTON STREET, GRAYSLAKE, IL 60030

CDB PROJECT NO.

DATE

SHEET NO.

OF ( )SHEETS

810-056-025TERRA ENGINEERING, LTD.

LARSON ENGINEERING OF ILLINOIS

CONSTRUCTION COST SYSTEMS, INC.1815 SOUTH MEYERS ROAD, SUITE 200OAKBROOK TERRACE, IL 60181

225 W. OHIO STREET - 4TH FLOORCHICAGO, IL 60654

1488 BOND STREET, SUITE 100NAPERVILLE, IL 60563

CIVIL ENGINEER

STRUCTURAL ENGINEER

COST ESTIMATING

PHONE: (312) 467-0123ext: 230

PHONE: (630) 357-0540

PHONE: (630) 678-0808

CARNOW CONIBEAR

600 W. VAN BUREN - #500CHICAGO, IL 60607

ASBESTOS ABATEMENT

PHONE: (312) 762-2936

Pat Quinn, GovernorState of Illinois

Illinois Capital Development Board

PHONE: (815) 477-4545

MEPFPT ENGINEER

ARCHITECT

PHONE: (312) 977-2800

DESIGNER(312) 787-4405

REVISIONS

CHECKED APPROVED

PROJ. MNGR.

NOTE: CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AND BE FULLY RESPONSIBLE FOR SAME.

DRAWN

ARCHITECT'S PROJECT NO.

SPF

211001.00

AFFILIATED ENGINEERS, INC.

10 SOUTH LASALLE STREET, SUITE 2700CHICAGO, IL 60603

LEGAT ARCHITECTS

80 NORTH VIRGINIA STREET, SUITE CCRYSTAL LAKE, IL 60014

BRUBAKER

900 NORTH LAKESHORE DRIVE #2703CHICAGO, ILLINOIS 60611

100% BID DOCUMENTS

dbHMS

303 W. Erie Street - #510CHICAGO, IL 60654

COMMISSIONING AUTHORITY

PHONE: (312) 915-0557 ext. 258

07.21.2014

COMD-102C

SECOND FLOOR COMMUNICATIONS DEMO PLAN - MODULE C

CHCH

KV

07.21.2014

0' 2' 4' 8' 16'

1 DISCONNECT AND REMOVE ALL OUTLETS AND HORIZONTAL CABLINGBACK TO SERVING IDF ROOMS.

SHEET KEYED NOTES

1/8" = 1'-0"1

SECOND FLOOR COMMUNICATIONS DEMOLITION PLAN - MODULE C

GENERAL NOTES

REFER TO SPECIFICATIONS FOR DIRECTIONS REGARDING DEMOLITIONWORK.

AREA OF DEMOLITION SHOWN IS FOR APPROXIMATION PURPOSES ONLY.ELECTRICAL CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGSFOR EXACT AREA OF DEMOLITION.

EQUIPMENT LOCATIONS SHOWN ARE APPROXIMATE AND SHALL BE FIELDVERIFIED.

FURNISH ALL LABOR, MATERIALS AND EQUIPMENT REQUIRED TOCOMPLETE DEMOLITION OF EXISTING ELECTRICAL EQUIPMENT ASSPECIFIED OR INDICATED. DISCONNECT, REMOVE AND RELOCATE ALLITEMS AS REQUIRED TO FACILITATE THE NEW CONSTRUCTION.

ELECTRICAL CONTRACTOR SHALL THOROUGHLY FAMILIARIZE HIMSELFWITH EXISTING ELECTRICAL SYSTEM, WHICH WILL BE AFFECTED BY THEDEMOLITION AND REMODELING WORK.

ELECTRICAL CONTRACTOR SHALL OBTAIN PERMISSION FROM USINGAGENCY'S REPRESENTATIVE TO SHUT OFF SERVICES OR SYSTEM, WHICHMAY AFFECT OTHER AREAS BEYOND THE LIMITS OF THE IMMEDIATEDEMOLITION AREA. SUCH PERMISSION WILL BE GRANTED ONLY AFTERUSING AGENCY'S REPRESENTATIVE IS INFORMED AS TO THE REASON FORAND DURATION OF THE SHUTDOWN AND IS SATISFIED THAT THESHUTDOWN CAN BE MADE WITH AS LITTLE INCONVENIENCE TO OTHERAREAS AS POSSIBLE.

1.

2.

3.

4.

5.

6.

GENERAL NOTES

REFER TO SPECIFICATIONS FOR DIRECTIONS REGARDING DEMOLITIONWORK.

AREA OF DEMOLITION SHOWN IS FOR APPROXIMATION PURPOSES ONLY.ELECTRICAL CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGSFOR EXACT AREA OF DEMOLITION.

EQUIPMENT LOCATIONS SHOWN ARE APPROXIMATE AND SHALL BE FIELDVERIFIED.

FURNISH ALL LABOR, MATERIALS AND EQUIPMENT REQUIRED TOCOMPLETE DEMOLITION OF EXISTING ELECTRICAL EQUIPMENT ASSPECIFIED OR INDICATED. DISCONNECT, REMOVE AND RELOCATE ALLITEMS AS REQUIRED TO FACILITATE THE NEW CONSTRUCTION.

ELECTRICAL CONTRACTOR SHALL THOROUGHLY FAMILIARIZE HIMSELFWITH EXISTING ELECTRICAL SYSTEM, WHICH WILL BE AFFECTED BY THEDEMOLITION AND REMODELING WORK.

ELECTRICAL CONTRACTOR SHALL OBTAIN PERMISSION FROM USINGAGENCY'S REPRESENTATIVE TO SHUT OFF SERVICES OR SYSTEM, WHICHMAY AFFECT OTHER AREAS BEYOND THE LIMITS OF THE IMMEDIATEDEMOLITION AREA. SUCH PERMISSION WILL BE GRANTED ONLY AFTERUSING AGENCY'S REPRESENTATIVE IS INFORMED AS TO THE REASON FORAND DURATION OF THE SHUTDOWN AND IS SATISFIED THAT THESHUTDOWN CAN BE MADE WITH AS LITTLE INCONVENIENCE TO OTHERAREAS AS POSSIBLE.

1.

2.

3.

4.

5.

6.

NO. DATE REMARKS

N

P

Q

R

12

O

1713 18161512.5

4n3.2n 5n 6n 7n 8n 9n 10n 11n 12n

B-n

A-n

12.7n

1.8n1n

A.7-n

D-n

E-n E-n

13n

2

2

W

AP

APMECHANICALROOM

S-005

WATER HEATER

S-002

2

2

ELEVATOR-1

E-1-1

ELEV. EQUIP.

S-001

STORAGE

S-003

CORRIDOR

C006

CORRIDOR

C012

ELEV. EQUIP.

S-002

C-n

13.1n

A.2-n

A.4-n

8.5n

SC

12A

GENERAL NOTES

REFER TO SHEET COM-000 FOR SYMBOLS AND ABBREVIATIONSAND ADDITIONAL GENERAL NOTES.

FIRESTOP ALL PENETRATIONS AS REQUIRED BY CODE.

ALL SIO'S ON THIS SHEET SHALL ROUTE TO IDF ROOMS S-106, S-213, OR S-309 FOR EACH FLOOR.

COORDINATE ALL CEILING MOUNTED DEVICES WITHREFLECTED CEILING PLANS PRIOR TO ROUGH-IN.

REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OFFIRE RATED WALLS.

COORDINATE ALL SIO HEIGHTS AND LOCATIONS WITHARCHITECT/USING AGENCY AND FURNITURE LAYOUT PRIOR TOROUGH-IN. ARCHITECTURAL INTERIOR ELEVATIONS TAKEPRECEDENCE OVER HEIGHTS SHOWN ON TECHNOLOGYDRAWINGS.

REFER TO ARCHITECTURAL DRAWINGS FOR CEILINGS ANDWALL TYPES. CONFIRM CEILING AND WALL ACCESSIBILITYPROPERTIES WITH ARCHITECTURAL PLANS.

INSTALL SURFACE-MOUNTED RACEWAY OUTLETS IN DUAL-CHANNEL RACEWAY. REFER TO ELECTRICAL DRAWINGS ANDSPECIFICATIONS.

ELECTRICAL CONTRACTOR SHALL USE BUTT JOINTS FORCONNECTING CABLE RACEWAY WITH-IN IDFs. CABLE TRAYOUTSIDE OF IDF ROOM SHALL USE RADIUSED 90 DEGREEBENDS AND "T" INTERSECTIONS AS SHOWN ON FLOOR PLANS.

1.

2.

3.

4.

5.

6.

7.

8.

9.

KEY PLAN

MODULE-A

COLLEGE OF LAKE COUNTYSCIENCE ADDITION AND RENOVATIONS

19351 WEST WASHINGTON STREET, GRAYSLAKE, IL 60030

CDB PROJECT NO.

DATE

SHEET NO.

OF ( )SHEETS

810-056-025TERRA ENGINEERING, LTD.

LARSON ENGINEERING OF ILLINOIS

CONSTRUCTION COST SYSTEMS, INC.1815 SOUTH MEYERS ROAD, SUITE 200OAKBROOK TERRACE, IL 60181

225 W. OHIO STREET - 4TH FLOORCHICAGO, IL 60654

1488 BOND STREET, SUITE 100NAPERVILLE, IL 60563

CIVIL ENGINEER

STRUCTURAL ENGINEER

COST ESTIMATING

PHONE: (312) 467-0123ext: 230

PHONE: (630) 357-0540

PHONE: (630) 678-0808

CARNOW CONIBEAR

600 W. VAN BUREN - #500CHICAGO, IL 60607

ASBESTOS ABATEMENT

PHONE: (312) 762-2936

Pat Quinn, GovernorState of Illinois

Illinois Capital Development Board

PHONE: (815) 477-4545

MEPFPT ENGINEER

ARCHITECT

PHONE: (312) 977-2800

DESIGNER(312) 787-4405

REVISIONS

CHECKED APPROVED

PROJ. MNGR.

NOTE: CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AND BE FULLY RESPONSIBLE FOR SAME.

DRAWN

ARCHITECT'S PROJECT NO.

SPF

211001.00

AFFILIATED ENGINEERS, INC.

10 SOUTH LASALLE STREET, SUITE 2700CHICAGO, IL 60603

LEGAT ARCHITECTS

80 NORTH VIRGINIA STREET, SUITE CCRYSTAL LAKE, IL 60014

BRUBAKER

900 NORTH LAKESHORE DRIVE #2703CHICAGO, ILLINOIS 60611

100% BID DOCUMENTS

dbHMS

303 W. Erie Street - #510CHICAGO, IL 60654

COMMISSIONING AUTHORITY

PHONE: (312) 915-0557 ext. 258

07.21.2014

COM-100A

LOWER LEVEL COMMUNICATIONS PLAN - MODULE A

CHCH

KV

07.21.2014

1/8" = 1'-0"1

LOWER LEVEL COMMUNICATIONS PLAN - MODULE A

0' 4' 8' 16' 32'

NO. DATE REMARKS

FD

FD

FD

12

1713 18161512.5

4n3.2n 5n 6n 7n 8n 9n 10n 11n 12n

B-n

A-n

12.7n1.8n1n

A.7-n

D-n

E-n

13n

W

2

ATS

S-114

MAIN ELEC. ROOM

S-117

MECHATRONICSLAB

S-108

WOMEN

S-110

MEN

S-112

CONTROL ROOM

S-103

LASER LAB 3

S-104

LASER LAB 2

S-102STAIR - S2

S-2

STAIR S-1

S-1

22

2

2

2

2

2

W

WW

W

AP

APAP

AP

AP

APAPAP

AP

AP

2

2

2

2

LASER LAB 4

S-105

LASER LAB 1

S-101

W

AP AP

AP

APAP AP AP AP

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

AP

AP

2

2

2

2

SC

SC

SC

SC

SC

SC

SC

SC SC

Room

C106

Room

C107

Room

C119

Room

C118

Room

C117

Room

C105

GENERATOR

S-116

WOMEN SHOWER

S-111

MEN SHOWER

S-113

FACULTY OFFICE

S-107

COM-4006

ELEVATOR-2

E-1-2CUSTODIAL

S-124

ATRIUM

S-121

IDF

S-106

CORRIDOR

S-120

CORRIDOR

S-115

STUDENT SPACE

S-119

VESTIBULE

V-1

CORRIDOR

S-118

VESTIBULE

V-2

JANITOR CLO.

S-109

2

2 2

2 2

2 2 2 2 2 2

2

2

2

2 2 2 2 2 2 2

2 2 22

2 2 2 2C-n

13.1n

A.2-n

A.4-n

8.5n

2

2

4

2

2 2

2

2

2

4" CABLE TRAY

SC

SCSC

SC

SC SC

SC SC

SC

4

+108"AFF4

12A

WW 444444444

1

1

1 1

1

55

1

5

5

5

5

15

1111

1

1

1 1 1

1

5555

5

5

5 5 5

5

6

6

1

1

4

4

7

7

7

7

7

7

7

7 7

1

1

1

1

1

1

1

1 18

GENERAL NOTES

REFER TO SHEET COM-000 FOR SYMBOLS AND ABBREVIATIONSAND ADDITIONAL GENERAL NOTES.

FIRESTOP ALL PENETRATIONS AS REQUIRED BY CODE.

ALL SIO'S ON THIS SHEET SHALL ROUTE TO IDF ROOMS S-106, S-213, OR S-309 FOR EACH FLOOR.

COORDINATE ALL CEILING MOUNTED DEVICES WITHREFLECTED CEILING PLANS PRIOR TO ROUGH-IN.

REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OFFIRE RATED WALLS.

COORDINATE ALL SIO HEIGHTS AND LOCATIONS WITHARCHITECT/USING AGENCY AND FURNITURE LAYOUT PRIOR TOROUGH-IN. ARCHITECTURAL INTERIOR ELEVATIONS TAKEPRECEDENCE OVER HEIGHTS SHOWN ON TECHNOLOGYDRAWINGS.

REFER TO ARCHITECTURAL DRAWINGS FOR CEILINGS ANDWALL TYPES. CONFIRM CEILING AND WALL ACCESSIBILITYPROPERTIES WITH ARCHITECTURAL PLANS.

INSTALL SURFACE-MOUNTED RACEWAY OUTLETS IN DUAL-CHANNEL RACEWAY. REFER TO ELECTRICAL DRAWINGS ANDSPECIFICATIONS.

ELECTRICAL CONTRACTOR SHALL USE BUTT JOINTS FORCONNECTING CABLE RACEWAY WITH-IN IDFs. CABLE TRAYOUTSIDE OF IDF ROOM SHALL USE RADIUSED 90 DEGREEBENDS AND "T" INTERSECTIONS AS SHOWN ON FLOOR PLANS.

1.

2.

3.

4.

5.

6.

7.

8.

9.

KEY PLAN

MODULE-A

COLLEGE OF LAKE COUNTYSCIENCE ADDITION AND RENOVATIONS

19351 WEST WASHINGTON STREET, GRAYSLAKE, IL 60030

CDB PROJECT NO.

DATE

SHEET NO.

OF ( )SHEETS

810-056-025TERRA ENGINEERING, LTD.

LARSON ENGINEERING OF ILLINOIS

CONSTRUCTION COST SYSTEMS, INC.1815 SOUTH MEYERS ROAD, SUITE 200OAKBROOK TERRACE, IL 60181

225 W. OHIO STREET - 4TH FLOORCHICAGO, IL 60654

1488 BOND STREET, SUITE 100NAPERVILLE, IL 60563

CIVIL ENGINEER

STRUCTURAL ENGINEER

COST ESTIMATING

PHONE: (312) 467-0123ext: 230

PHONE: (630) 357-0540

PHONE: (630) 678-0808

CARNOW CONIBEAR

600 W. VAN BUREN - #500CHICAGO, IL 60607

ASBESTOS ABATEMENT

PHONE: (312) 762-2936

Pat Quinn, GovernorState of Illinois

Illinois Capital Development Board

PHONE: (815) 477-4545

MEPFPT ENGINEER

ARCHITECT

PHONE: (312) 977-2800

DESIGNER(312) 787-4405

REVISIONS

CHECKED APPROVED

PROJ. MNGR.

NOTE: CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AND BE FULLY RESPONSIBLE FOR SAME.

DRAWN

ARCHITECT'S PROJECT NO.

SPF

211001.00

AFFILIATED ENGINEERS, INC.

10 SOUTH LASALLE STREET, SUITE 2700CHICAGO, IL 60603

LEGAT ARCHITECTS

80 NORTH VIRGINIA STREET, SUITE CCRYSTAL LAKE, IL 60014

BRUBAKER

900 NORTH LAKESHORE DRIVE #2703CHICAGO, ILLINOIS 60611

100% BID DOCUMENTS

dbHMS

303 W. Erie Street - #510CHICAGO, IL 60654

COMMISSIONING AUTHORITY

PHONE: (312) 915-0557 ext. 258

07.21.2014

COM-101A

FIRST FLOOR COMMUNICATIONS PLAN - MODULE A

CHCH

KV

07.21.2014

1/8" = 1'-0"1

FIRST FLOOR COMMUNICATIONS PLAN - MODULE A

2

0' 4' 8' 16' 32'

SHEET KEYNOTES

1 TYPICAL (2) 4" CONDUIT SLEEVES BUSHED AND CAPPED FOR FUTURE.

2 OUTLET FOR CORRIDOR MONITOR CO-LOCATE IN AV BOX. REFER TO AV SERIESDRAWINGS.

1

1

1

1

11

2

3 EACH FLOOR OUTLET INSTALLED IN SAME ACTIVATION POINT AS ELECTRICALRECEPTACLES. FLOOR OUTLET CABLES ROUTED TO IDF VIA IN-FLOOR TRENCH.REFER TO ELECTRICAL DRAWINGS.

3

4 CEILING MOUNTED OUTLET FOR PA SYSTEM.

5 OUTLET FOR LAB MONITORS CO-LOCATE IN AV BOX. REFER TO AV SERIESDRAWINGS.

6 OUTLET FOR CARD READER. REFER TO SECURITY SERIES DRAWINGS.

7 CEILING MOUNTED OUTLET FOR SPEAKERS CO-LATE IN AV BOX. REFER TO AVSERIES DRAWINGS.

8 CEILING MOUNTED DATA JACK FOR FUTURE PROJECTOR.

NO. DATE REMARKS

..

FD FD

FD

FD

FDFD

12

1713 18161512.5

4n3.2n 5n 6n 7n 8n 9n 10n 11n 12n

B-n

A-n

12.7n1.8n1n

A.7-n

D-n

E-n

13n

MEN

S-210

WOMEN

S-209

CHEMICALSTORAGE

S-206

STAIR S-1

S-1

WORK AREA

S-203A

STORAGE

S-203

WW

2 22

22

222

2

2

COM-4004

STUDENT SPACE

S-216

BRIDGE

S-217

CORRIDOR

S-214

STUDENT SPACE

S-218

CORRIDOR

S-215

JANITOR CLO.

S-208

CART STORAGE

S-207

APAP

AP

AP

AP AP AP

AP AP

AP

AP

AP

AP AP

APAPAP AP AP APAP

2

2

2

2 2

2

2

W

IDF

S-213

LAB MANAGER'SOFFICE

S-204

CORRIDOR

C220

CORRIDOR

C201ACORRIDOR

C-221

ELEVATOR

E-1

ELEC. CLOSET

S-212 FACULTY OFFICE

S-211

GLASSWASH /PREP LAB

S-205

CHEMISTRY LAB

S-202

ORGANIC CHEM.INSTR. LAB

S-201

ORGANIC CHEM.LAB

S-2002

2 22 22 2 22 2 22 22 2 2 22 2 2 22 2

2

2

2

2

2

1

2

1

2

C-n

13.1n

A.2-n

A.4-n

8.5n

22

AP

(2) 4" CONDUIT SLEEVESTHROUGH 2-HOUR RATED WALL

SC

SC

SC SC

SCSC

SC

SC SC

42

4

12"x4"CABLE TRAY

18"x4"CABLE TRAY

12"x4"CABLE TRAY

12"x4"CABLE TRAY

12A

44

4

44

WW

555555555

6 6

11

1

1 166

6

1166

6 6

11

8

1

8

1

8

1

8

1

8

1

8

1

8

1

8

1

9

9

GENERAL NOTES

REFER TO SHEET COM-000 FOR SYMBOLS AND ABBREVIATIONSAND ADDITIONAL GENERAL NOTES.

FIRESTOP ALL PENETRATIONS AS REQUIRED BY CODE.

ALL SIO'S ON THIS SHEET SHALL ROUTE TO IDF ROOMS S-106, S-213, OR S-309 FOR EACH FLOOR.

COORDINATE ALL CEILING MOUNTED DEVICES WITHREFLECTED CEILING PLANS PRIOR TO ROUGH-IN.

REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OFFIRE RATED WALLS.

COORDINATE ALL SIO HEIGHTS AND LOCATIONS WITHARCHITECT/USING AGENCY AND FURNITURE LAYOUT PRIOR TOROUGH-IN. ARCHITECTURAL INTERIOR ELEVATIONS TAKEPRECEDENCE OVER HEIGHTS SHOWN ON TECHNOLOGYDRAWINGS.

REFER TO ARCHITECTURAL DRAWINGS FOR CEILINGS ANDWALL TYPES. CONFIRM CEILING AND WALL ACCESSIBILITYPROPERTIES WITH ARCHITECTURAL PLANS.

INSTALL SURFACE-MOUNTED RACEWAY OUTLETS IN DUAL-CHANNEL RACEWAY. REFER TO ELECTRICAL DRAWINGS ANDSPECIFICATIONS.

ELECTRICAL CONTRACTOR SHALL USE BUTT JOINTS FORCONNECTING CABLE RACEWAY WITH-IN IDFs. CABLE TRAYOUTSIDE OF IDF ROOM SHALL USE RADIUSED 90 DEGREEBENDS AND "T" INTERSECTIONS AS SHOWN ON FLOOR PLANS.

1.

2.

3.

4.

5.

6.

7.

8.

9.

KEY PLAN

MODULE-A

COLLEGE OF LAKE COUNTYSCIENCE ADDITION AND RENOVATIONS

19351 WEST WASHINGTON STREET, GRAYSLAKE, IL 60030

CDB PROJECT NO.

DATE

SHEET NO.

OF ( )SHEETS

810-056-025TERRA ENGINEERING, LTD.

LARSON ENGINEERING OF ILLINOIS

CONSTRUCTION COST SYSTEMS, INC.1815 SOUTH MEYERS ROAD, SUITE 200OAKBROOK TERRACE, IL 60181

225 W. OHIO STREET - 4TH FLOORCHICAGO, IL 60654

1488 BOND STREET, SUITE 100NAPERVILLE, IL 60563

CIVIL ENGINEER

STRUCTURAL ENGINEER

COST ESTIMATING

PHONE: (312) 467-0123ext: 230

PHONE: (630) 357-0540

PHONE: (630) 678-0808

CARNOW CONIBEAR

600 W. VAN BUREN - #500CHICAGO, IL 60607

ASBESTOS ABATEMENT

PHONE: (312) 762-2936

Pat Quinn, GovernorState of Illinois

Illinois Capital Development Board

PHONE: (815) 477-4545

MEPFPT ENGINEER

ARCHITECT

PHONE: (312) 977-2800

DESIGNER(312) 787-4405

REVISIONS

CHECKED APPROVED

PROJ. MNGR.

NOTE: CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CO NDITIONS AT JOB SITE AND BE FULLY RESPONSIBLE FOR S AME.

DRAWN

ARCHITECT'S PROJECT NO.

SPF

211001.00

AFFILIATED ENGINEERS, INC.

10 SOUTH LASALLE STREET, SUITE 2700CHICAGO, IL 60603

LEGAT ARCHITECTS

80 NORTH VIRGINIA STREET, SUITE CCRYSTAL LAKE, IL 60014

BRUBAKER

900 NORTH LAKESHORE DRIVE #2703CHICAGO, ILLINOIS 60611

100% BID DOCUMENTS

dbHMS

303 W. Erie Street - #510CHICAGO, IL 60654

COMMISSIONING AUTHORITY

PHONE: (312) 915-0557 ext. 258

07.21.2014

COM-102A

SECOND FLOOR COMMUNICATIONS PLAN - MODULE A

CHCH

KV

07.21.2014

1/8" = 1'-0"1

SECOND FLOOR COMMUNICATIONS PLAN - MODULE A

1 MOUNT OUTLETS WITHIN TABLETOP SURFACE OUTLET. REFER TO ELECTRICAL DRAWINGS.

SHEET KEYED NOTES

2 INSTALL OUTLET AT AV CEILING BOX CO-LOCATE IN AV BOX. REFER TO AV DRAWINGS FOR LOCATION.

0' 4' 8' 16' 32'

3 OUTLET FOR CORRIDOR MONITOR CO-LOCATE IN AV BOX. REFER TO AV SERIES DRAWINGS.

4 MOUNT 4-PORT DATA OUTLET WITHIN BENCH ADJACENT TO AUDIO/VISUAL CABINET (AVC).REFER TO AV-SERIES DRAWINGS FOR AVC LOCATION.

5 CEILING MOUNTED OUTLET FOR PA SYSTEM.

6 OUTLET FOR LAB MONITORS CO-LOCATE IN AV BOX. REFER TO AV SERIES DRAWINGS.

7 CEILING MOUNTED OUTLET FOR LAB PROJECTORS CO-LOCATE IN AV BOX. REFER TO AVSERIES DRAWINGS.

8 CEILING MOUNTED OUTLET FOR SPEAKERS CO-LOCATE IN AV BOX. REFER TO AV SERIES DRAWINGS.

9 CEILING MOUNTED DATA JACK FOR FUTURE PROJECTOR.

NO. DATE REMARKS

DN

DN

..

. .

MB

DN

FD FD

A1

C

F.3

H

J

L

N

EM

EK

EJ.8

EH

EE

EF

1 42 7 10 12

O

5.7

17

3 6

E9

11 13

1816.21615.915.715

12.57.55

E7.5

15.8

4n3.2n 5n 6n1.8n1n

E-n

A & P LAB 2

C-202

A & P LAB 1

C-201

CADAVER LAB 1

C-201A

CADAVER LAB 2

C-202A

GLASSWASH

B-232B

CLASSROOM

B-219

EQUIP. STORAGE

B-232C

MICROBIOLOGYLAB 1

B-218

MEDIA PREP

B-232A

MICROBIOLOGYLAB 2

B-231

PREP

B-232

PREP/STAGING

C-203

BRIDGE

S-217

2

2

2

2

2

2

2

2

2

2

2

22

2

2

2

2

2

2

2

2

2

2

2

4

2

2

2

22

2

2

2 2 2 2 2

2

2

2

2

2

2

2

2

2

2

2

2

CORRIDOR-1

B226H-1

CORRIDOR-2

B226H-2

CORRIDOR-1

B223-1

CORRIDOR-2

B223-2

CORRIDOR

C201ACORRIDOR

C-221

2

2

2

2

22 22

444

2

44

22

44

2

AP

2

2

AP

AP

AP

AP

AP

AP

SC

SC

SC

SC

SC

SC

SC

SC SC

SC

12"x4"CABLE TRAY

4 4

12"W x4"D CABLE TRAY(TYPICAL)

M

K

J.8

G

F

E

B1

C1

D1

D

12A

9

411 4

1 4 1 4

3 3

21

1 2

1

1

1 1

2

2

3

1

3

1

3

1

12

5

1

5

1

5

1

5

1

5

1

5

1

5

1

5

1

5

1

5

1

5

1

5

1

5

1

5

1

5

1

5

1

GENERAL NOTES

REFER TO SHEET COM-000 FOR SYMBOLS AND ABBREVIATIONSAND ADDITIONAL GENERAL NOTES.

FIRESTOP ALL PENETRATIONS AS REQUIRED BY CODE.

ALL SIO'S ON THIS SHEET SHALL ROUTE TO IDF ROOMS S-106, S-213, OR S-309 FOR EACH FLOOR.

COORDINATE ALL CEILING MOUNTED DEVICES WITHREFLECTED CEILING PLANS PRIOR TO ROUGH-IN.

REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OFFIRE RATED WALLS.

COORDINATE ALL SIO HEIGHTS AND LOCATIONS WITHARCHITECT/USING AGENCY AND FURNITURE LAYOUT PRIOR TOROUGH-IN. ARCHITECTURAL INTERIOR ELEVATIONS TAKEPRECEDENCE OVER HEIGHTS SHOWN ON TECHNOLOGYDRAWINGS.

REFER TO ARCHITECTURAL DRAWINGS FOR CEILINGS ANDWALL TYPES. CONFIRM CEILING AND WALL ACCESSIBILITYPROPERTIES WITH ARCHITECTURAL PLANS.

INSTALL SURFACE-MOUNTED RACEWAY OUTLETS IN DUAL-CHANNEL RACEWAY. REFER TO ELECTRICAL DRAWINGS ANDSPECIFICATIONS.

ELECTRICAL CONTRACTOR SHALL USE BUTT JOINTS FORCONNECTING CABLE RACEWAY WITH-IN IDFs. CABLE TRAYOUTSIDE OF IDF ROOM SHALL USE RADIUSED 90 DEGREEBENDS AND "T" INTERSECTIONS AS SHOWN ON FLOOR PLANS.

1.

2.

3.

4.

5.

6.

7.

8.

9.

KEY PLAN

MO

DU

LE-B

COLLEGE OF LAKE COUNTYSCIENCE ADDITION AND RENOVATIONS

19351 WEST WASHINGTON STREET, GRAYSLAKE, IL 60030

CDB PROJECT NO.

DATE

SHEET NO.

OF ( )SHEETS

810-056-025TERRA ENGINEERING, LTD.

LARSON ENGINEERING OF ILLINOIS

CONSTRUCTION COST SYSTEMS, INC.1815 SOUTH MEYERS ROAD, SUITE 200OAKBROOK TERRACE, IL 60181

225 W. OHIO STREET - 4TH FLOORCHICAGO, IL 60654

1488 BOND STREET, SUITE 100NAPERVILLE, IL 60563

CIVIL ENGINEER

STRUCTURAL ENGINEER

COST ESTIMATING

PHONE: (312) 467-0123ext: 230

PHONE: (630) 357-0540

PHONE: (630) 678-0808

CARNOW CONIBEAR

600 W. VAN BUREN - #500CHICAGO, IL 60607

ASBESTOS ABATEMENT

PHONE: (312) 762-2936

Pat Quinn, GovernorState of Illinois

Illinois Capital Development Board

PHONE: (815) 477-4545

MEPFPT ENGINEER

ARCHITECT

PHONE: (312) 977-2800

DESIGNER(312) 787-4405

REVISIONS

CHECKED APPROVED

PROJ. MNGR.

NOTE: CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AND BE FULLY RESPONSIBLE FOR SAME.

DRAWN

ARCHITECT'S PROJECT NO.

SPF

211001.00

AFFILIATED ENGINEERS, INC.

10 SOUTH LASALLE STREET, SUITE 2700CHICAGO, IL 60603

LEGAT ARCHITECTS

80 NORTH VIRGINIA STREET, SUITE CCRYSTAL LAKE, IL 60014

BRUBAKER

900 NORTH LAKESHORE DRIVE #2703CHICAGO, ILLINOIS 60611

100% BID DOCUMENTS

dbHMS

303 W. Erie Street - #510CHICAGO, IL 60654

COMMISSIONING AUTHORITY

PHONE: (312) 915-0557 ext. 258

07.21.2014

COM-102B

SECOND FLOOR COMMUNICATIONS PLAN - MODULE B

CHCH

KV

07.21.2014

1/8" = 1'-0"1

SECOND FLOOR COMMUNICATIONS PLAN - MODULE B

0' 2' 4' 8' 16'

1 MOUNT 4-PORT DATA OUTLET WITHIN BENCH ADJACENT TO AUDIO/VISUALCABINET (AVC). REFER TO AV-SERIES DRAWINGS FOR AVC LOCATION.

SHEET KEYED NOTES

2 OUTLET FOR LAB MONITORS CO-LOCATE IN AV BOX. REFER TO AVSERIES DRAWINGS.

3 CEILING MOUNTED OUTLET FOR LAB PROJECTORS CO-LATE IN AV BOX.REFER TO AV SERIES DRAWINGS.

INSTALL OUTLET IN AV CEILING BOX CO-LOCATE IN AV BOX. REFER TOAV SERIES DRAWINGS.

4

CEILING MOUNTED OUTLET FOR SPEAKERS CO-LOCATE IN AV BOX. REFERTO AV SERIES DRAWINGS.

5

NO. DATE REMARKS

DN

DN

ICE

RE

F

.R

EF

RE

FC

HR

EF

RE

F

RE

F

. ..

DN

DN

FD

. ..

N

1

2.1

42 P

Q

R

S

U

V

7 10 12

O

W

5.7

5.3

3 6 11 1312.57.55

B-n

A-n

1n

A.7-n

D-n

E-n

CLASSROOM

C-233ENVIRONMENTALBIO / CONCEPTS

LAB

C-222

BIOLOGY LAB

C-223

BIOLOGY LAB

C-224

BIOLOGY 2 /ZOOLOGY / STEM

LAB

C-225

CORRIDOR

C-235

STUDENT SPACE

S-216

2 2

24

4

AP

AP

AP

AP

AP

AP

AP

AP

AP

AP

APAP

APAP

CORRIDOR

C220

CORRIDOR

C221

1

2

2 22

2

2

NIC

LIVEANIMAL

STORAGE

C-228GREENHOUSE

C-226

STORAGE

C-229

BIOLOGYPREP

C-230

BIOLOGYMULTI-USESUPPORT

C-227

OFFICE

C-231

C-n

A.2-n

A.4-n

ALTERNATE #E-3

4

4

4

SCSC

SC

SC

2

2

2

4

2

12"W x 4"DCABLE TRAY(TYPICAL)

T

9

4

14

14

14

4

1

3

13

1

6

1

31

3

13

1

3

1 1

11

1 1

1

3

33

3 3

3

5

5

5

6

1

6

1

6

1

6

1

6

1

6

1

6

1

6

1

6

1

6

1

6

1

6

1

6

1

6

1

6

1

6

1

6

1

6

1

6

1

7

7

7

1 2.1 42

S

U

V

5.75.3

2

2

2 2

AP

AP

AP

AP

AP

AP

AP

22

ALTERNATE #E-2

NICGREENHOUSE

C-226

ORGANISMSTORAGE

C-227

BIOLOGYSTORAGE

C-228

PREP&

GLASSWASH

C-230

COLLECTIONS

C-229

WORKROOM

C-231

LABMANAGER

C-232

STORAGE

C-228A

T

GENERAL NOTES

REFER TO SHEET COM-000 FOR SYMBOLS AND ABBREVIATIONSAND ADDITIONAL GENERAL NOTES.

FIRESTOP ALL PENETRATIONS AS REQUIRED BY CODE.

ALL SIO'S ON THIS SHEET SHALL ROUTE TO IDF ROOMS S-106, S-213, OR S-309 FOR EACH FLOOR.

COORDINATE ALL CEILING MOUNTED DEVICES WITHREFLECTED CEILING PLANS PRIOR TO ROUGH-IN.

REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OFFIRE RATED WALLS.

COORDINATE ALL SIO HEIGHTS AND LOCATIONS WITHARCHITECT/USING AGENCY AND FURNITURE LAYOUT PRIOR TOROUGH-IN. ARCHITECTURAL INTERIOR ELEVATIONS TAKEPRECEDENCE OVER HEIGHTS SHOWN ON TECHNOLOGYDRAWINGS.

REFER TO ARCHITECTURAL DRAWINGS FOR CEILINGS ANDWALL TYPES. CONFIRM CEILING AND WALL ACCESSIBILITYPROPERTIES WITH ARCHITECTURAL PLANS.

INSTALL SURFACE-MOUNTED RACEWAY OUTLETS IN DUAL-CHANNEL RACEWAY. REFER TO ELECTRICAL DRAWINGS ANDSPECIFICATIONS.

ELECTRICAL CONTRACTOR SHALL USE BUTT JOINTS FORCONNECTING CABLE RACEWAY WITH-IN IDFs. CABLE TRAYOUTSIDE OF IDF ROOM SHALL USE RADIUSED 90 DEGREEBENDS AND "T" INTERSECTIONS AS SHOWN ON FLOOR PLANS.

1.

2.

3.

4.

5.

6.

7.

8.

9.

KEY PLANMOD

ULE

-C

COLLEGE OF LAKE COUNTYSCIENCE ADDITION AND RENOVATIONS

19351 WEST WASHINGTON STREET, GRAYSLAKE, IL 60030

CDB PROJECT NO.

DATE

SHEET NO.

OF ( )SHEETS

810-056-025TERRA ENGINEERING, LTD.

LARSON ENGINEERING OF ILLINOIS

CONSTRUCTION COST SYSTEMS, INC.1815 SOUTH MEYERS ROAD, SUITE 200OAKBROOK TERRACE, IL 60181

225 W. OHIO STREET - 4TH FLOORCHICAGO, IL 60654

1488 BOND STREET, SUITE 100NAPERVILLE, IL 60563

CIVIL ENGINEER

STRUCTURAL ENGINEER

COST ESTIMATING

PHONE: (312) 467-0123ext: 230

PHONE: (630) 357-0540

PHONE: (630) 678-0808

CARNOW CONIBEAR

600 W. VAN BUREN - #500CHICAGO, IL 60607

ASBESTOS ABATEMENT

PHONE: (312) 762-2936

Pat Quinn, GovernorState of Illinois

Illinois Capital Development Board

PHONE: (815) 477-4545

MEPFPT ENGINEER

ARCHITECT

PHONE: (312) 977-2800

DESIGNER(312) 787-4405

REVISIONS

CHECKED APPROVED

PROJ. MNGR.

NOTE: CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AND BE FULLY RESPONSIBLE FOR SAME.

DRAWN

ARCHITECT'S PROJECT NO.

SPF

211001.00

AFFILIATED ENGINEERS, INC.

10 SOUTH LASALLE STREET, SUITE 2700CHICAGO, IL 60603

LEGAT ARCHITECTS

80 NORTH VIRGINIA STREET, SUITE CCRYSTAL LAKE, IL 60014

BRUBAKER

900 NORTH LAKESHORE DRIVE #2703CHICAGO, ILLINOIS 60611

100% BID DOCUMENTS

dbHMS

303 W. Erie Street - #510CHICAGO, IL 60654

COMMISSIONING AUTHORITY

PHONE: (312) 915-0557 ext. 258

07.21.2014

COM-102C

SECOND FLOOR COMMUNICATIONS PLAN - MODULE C

CHCH

KV

07.21.2014

1/8" = 1'-0"1

SECOND FLOOR COMMUNICATIONS PLAN - MODULE C

SHEET KEYED NOTES

1 MOUNT 4-PORT DATA OUTLET WITHIN BENCH ADJACENT TOAUDIO/VISUAL CABINET (AVC). REFER TO AV-SERIESDRAWINGSFOR AVC LOCATION.

CONNECT CABLE TRAY TO CABLE TRAYINSTALLED UNDER ALTERNATE #E-2.

OUTLET FOR LAB MONITOR CO-LOCATE IN AV BOX. REFER TOAV SERIES DRAWINGS.

CEILING MOUNTED OUTLET FOR LAB PROJECTORS CO-LATEIN AV BOX. REFER TO AV SERIES DRAWINGS.

INSTALL OUTLET AT AV CEILING BOX CO-LOCATE IN AV BOX.REFER TO AV SERIES DRAWINGS.

CEILING MOUNTED OUTLET FOR SPEAKERS CO-LOCATE IN AVBOX. REFER TO AV SERIES DRAWINGS.

CEILING MOUNTED DATA JACK FOR FUTURE PROJECTOR.

0' 4' 8' 16' 32'

1/8" = 1'-0"2

SECOND FLOOR COMMUNICATIONS PLAN - MODULE C ALTERNATE 2

2

3

4

5

6

NO. DATE REMARKS

7

.FD

FD

FD FD FDFD

N

P

Q

R

12

O

4n3.2n 5n 6n 7n 8n 9n 10n 11n 12n

B-n

A-n

12.7n1.8n1n

A.7-n

D-n

E-n

13n

2

2

2

2 2 2

2

2 2

W APAP

AP

AP AP AP AP

AP

WOMEN

S-305

MEN

S-306

STAIR S-1

S-1COM-4002

2

2

2

2

2

2

2

2

2

2

2

2

AP AP

AP

AP AP AP AP AP

APAPAP AP AP AP

2

2

2

2

2

2

2

2

2

AP

IDF

S-309

CORRIDOR

S-313

CORRIDOR

S-312

JANITOR CLO.

S-310

CART STORAGE

S-311ELEVATOR-4

E-1-4

DRY STORAGE

S-304

FACULTY OFFICE

S-307ELEC. CLOSET

S-308

CHEMISTRY LAB

S-303

CHEMISTRY LAB

S-302INSTRUMENT LAB

S-301

CHEMISTRY LAB

S-300

2

1

2

12

1

C-n

13.1n8.5n

AP

2 2 2 2 2 2 2 2 2 2 2 2

4

2 2

SC

SC SC SC SC

SCSC

4

2

44

12"W x 4"DCABLE TRAY(TYPICAL)

12A

4

3

43

43

WW

4

44444444

5

11

11111

1111 1 1

5

55555

5 5 5 5 5 5

1

6

1

6

1

6

1

6

1

6

1

6

1

6

1

6

1

6

1

6

1

6

1

6

7 7

7

GENERAL NOTES

REFER TO SHEET COM-000 FOR SYMBOLS AND ABBREVIATIONSAND ADDITIONAL GENERAL NOTES.

FIRESTOP ALL PENETRATIONS AS REQUIRED BY CODE.

ALL SIO'S ON THIS SHEET SHALL ROUTE TO IDF ROOMS S-106, S-213, OR S-309 FOR EACH FLOOR.

COORDINATE ALL CEILING MOUNTED DEVICES WITHREFLECTED CEILING PLANS PRIOR TO ROUGH-IN.

REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OFFIRE RATED WALLS.

COORDINATE ALL SIO HEIGHTS AND LOCATIONS WITHARCHITECT/USING AGENCY AND FURNITURE LAYOUT PRIOR TOROUGH-IN. ARCHITECTURAL INTERIOR ELEVATIONS TAKEPRECEDENCE OVER HEIGHTS SHOWN ON TECHNOLOGYDRAWINGS.

REFER TO ARCHITECTURAL DRAWINGS FOR CEILINGS ANDWALL TYPES. CONFIRM CEILING AND WALL ACCESSIBILITYPROPERTIES WITH ARCHITECTURAL PLANS.

INSTALL SURFACE-MOUNTED RACEWAY OUTLETS IN DUAL-CHANNEL RACEWAY. REFER TO ELECTRICAL DRAWINGS ANDSPECIFICATIONS.

ELECTRICAL CONTRACTOR SHALL USE BUTT JOINTS FORCONNECTING CABLE RACEWAY WITH-IN IDFs. CABLE TRAYOUTSIDE OF IDF ROOM SHALL USE RADIUSED 90 DEGREEBENDS AND "T" INTERSECTIONS AS SHOWN ON FLOOR PLANS.

1.

2.

3.

4.

5.

6.

7.

8.

9.

KEY PLAN

MODULE-A

COLLEGE OF LAKE COUNTYSCIENCE ADDITION AND RENOVATIONS

19351 WEST WASHINGTON STREET, GRAYSLAKE, IL 60030

CDB PROJECT NO.

DATE

SHEET NO.

OF ( )SHEETS

810-056-025TERRA ENGINEERING, LTD.

LARSON ENGINEERING OF ILLINOIS

CONSTRUCTION COST SYSTEMS, INC.1815 SOUTH MEYERS ROAD, SUITE 200OAKBROOK TERRACE, IL 60181

225 W. OHIO STREET - 4TH FLOORCHICAGO, IL 60654

1488 BOND STREET, SUITE 100NAPERVILLE, IL 60563

CIVIL ENGINEER

STRUCTURAL ENGINEER

COST ESTIMATING

PHONE: (312) 467-0123ext: 230

PHONE: (630) 357-0540

PHONE: (630) 678-0808

CARNOW CONIBEAR

600 W. VAN BUREN - #500CHICAGO, IL 60607

ASBESTOS ABATEMENT

PHONE: (312) 762-2936

Pat Quinn, GovernorState of Illinois

Illinois Capital Development Board

PHONE: (815) 477-4545

MEPFPT ENGINEER

ARCHITECT

PHONE: (312) 977-2800

DESIGNER(312) 787-4405

REVISIONS

CHECKED APPROVED

PROJ. MNGR.

NOTE: CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AND BE FULLY RESPONSIBLE FOR SAME.

DRAWN

ARCHITECT'S PROJECT NO.

SPF

211001.00

AFFILIATED ENGINEERS, INC.

10 SOUTH LASALLE STREET, SUITE 2700CHICAGO, IL 60603

LEGAT ARCHITECTS

80 NORTH VIRGINIA STREET, SUITE CCRYSTAL LAKE, IL 60014

BRUBAKER

900 NORTH LAKESHORE DRIVE #2703CHICAGO, ILLINOIS 60611

100% BID DOCUMENTS

dbHMS

303 W. Erie Street - #510CHICAGO, IL 60654

COMMISSIONING AUTHORITY

PHONE: (312) 915-0557 ext. 258

07.21.2014

COM-103A

THIRD FLOOR COMMUNICATIONS PLAN - MODULE A

CHCH

KV

07.21.2014

1/8" = 1'-0"1

THIRD FLOOR COMMUNICATIONS PLAN - MODULE A

0' 4' 8' 16' 32'

SHEET KEYNOTES

1 MOUNT OUTLETS WITHIN TABLETOP SURFACE OUTLET.REFER TO ELECTRICAL DRAWINGS.

INSTALL OUTLET AT AV CEILING BOX CO-LATE IN AV BOX.REFER TO AV DRAWINGS FOR LOCATION.

MOUNT 4-PORT DATA OUTLET WITHIN BENCH ADJACENT TOAUDIO/VISUAL CABINET (AVC). REFER TO AV-SERIESDRAWINGS FOR AVC LOCATIONS.

CEILING MOUNTED OUTLET FOR PA SYSTEM.

OUTLET FOR LAB MONITORS CO-LOCATE IN AV BOX. REFERTO AV SERIES DRAWINGS.

CEILING MOUNTED OUTLET FOR SPEAKERS CO-LATE IN AVBOX. REFER TO AVE SERIES DRAWINGS.

CEILING MOUNTED DATA JACK FOR FUTURE PROJECTOR.

2

3

4

5

6

7

NO. DATE REMARKS

4n3.2n 5n 6n 7n 8n 9n 10n 11n 12n

B-n

A-n

12.7n1.8n1n

A.7-n

D-n

E-n

13n

APAPAP

2

W

W

STAIR S-1

S-1

MECHANICALPENTHOUSE

S-PH-400

ELEVATOR-5

E-1-5

C-n

13.1n8.5n

WALL MTD.WP

1

GENERAL NOTES

REFER TO SHEET COM-000 FOR SYMBOLS AND ABBREVIATIONSAND ADDITIONAL GENERAL NOTES.

FIRESTOP ALL PENETRATIONS AS REQUIRED BY CODE.

ALL SIO'S ON THIS SHEET SHALL ROUTE TO IDF ROOMS S-106, S-213, OR S-309 FOR EACH FLOOR.

COORDINATE ALL CEILING MOUNTED DEVICES WITHREFLECTED CEILING PLANS PRIOR TO ROUGH-IN.

REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OFFIRE RATED WALLS.

COORDINATE ALL SIO HEIGHTS AND LOCATIONS WITHARCHITECT/USING AGENCY AND FURNITURE LAYOUT PRIOR TOROUGH-IN. ARCHITECTURAL INTERIOR ELEVATIONS TAKEPRECEDENCE OVER HEIGHTS SHOWN ON TECHNOLOGYDRAWINGS.

REFER TO ARCHITECTURAL DRAWINGS FOR CEILINGS ANDWALL TYPES. CONFIRM CEILING AND WALL ACCESSIBILITYPROPERTIES WITH ARCHITECTURAL PLANS.

INSTALL SURFACE-MOUNTED RACEWAY OUTLETS IN DUAL-CHANNEL RACEWAY. REFER TO ELECTRICAL DRAWINGS ANDSPECIFICATIONS.

ELECTRICAL CONTRACTOR SHALL USE BUTT JOINTS FORCONNECTING CABLE RACEWAY WITH-IN IDFs. CABLE TRAYOUTSIDE OF IDF ROOM SHALL USE RADIUSED 90 DEGREEBENDS AND "T" INTERSECTIONS AS SHOWN ON FLOOR PLANS.

1.

2.

3.

4.

5.

6.

7.

8.

9.

KEY PLAN

MODULE-A

COLLEGE OF LAKE COUNTYSCIENCE ADDITION AND RENOVATIONS

19351 WEST WASHINGTON STREET, GRAYSLAKE, IL 60030

CDB PROJECT NO.

DATE

SHEET NO.

OF ( )SHEETS

810-056-025TERRA ENGINEERING, LTD.

LARSON ENGINEERING OF ILLINOIS

CONSTRUCTION COST SYSTEMS, INC.1815 SOUTH MEYERS ROAD, SUITE 200OAKBROOK TERRACE, IL 60181

225 W. OHIO STREET - 4TH FLOORCHICAGO, IL 60654

1488 BOND STREET, SUITE 100NAPERVILLE, IL 60563

CIVIL ENGINEER

STRUCTURAL ENGINEER

COST ESTIMATING

PHONE: (312) 467-0123ext: 230

PHONE: (630) 357-0540

PHONE: (630) 678-0808

CARNOW CONIBEAR

600 W. VAN BUREN - #500CHICAGO, IL 60607

ASBESTOS ABATEMENT

PHONE: (312) 762-2936

Pat Quinn, GovernorState of Illinois

Illinois Capital Development Board

PHONE: (815) 477-4545

MEPFPT ENGINEER

ARCHITECT

PHONE: (312) 977-2800

DESIGNER(312) 787-4405

REVISIONS

CHECKED APPROVED

PROJ. MNGR.

NOTE: CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AND BE FULLY RESPONSIBLE FOR SAME.

DRAWN

ARCHITECT'S PROJECT NO.

SPF

211001.00

AFFILIATED ENGINEERS, INC.

10 SOUTH LASALLE STREET, SUITE 2700CHICAGO, IL 60603

LEGAT ARCHITECTS

80 NORTH VIRGINIA STREET, SUITE CCRYSTAL LAKE, IL 60014

BRUBAKER

900 NORTH LAKESHORE DRIVE #2703CHICAGO, ILLINOIS 60611

100% BID DOCUMENTS

dbHMS

303 W. Erie Street - #510CHICAGO, IL 60654

COMMISSIONING AUTHORITY

PHONE: (312) 915-0557 ext. 258

07.21.2014

COM-104A

PENTHOUSE COMMUNICATIONS PLAN - MODULE A

CHCH

KV

07.21.2014

1/8" = 1'-0"1

PENTHOUSE COMMUNICATIONS PLAN - MODULE A

0' 4' 8' 16' 32'

SHEET KEYED NOTES

1 OUTLET FOR BAS WORKSTATION COORDINATEEXACT LOCATION WITH USING AGENCY PRIOR TOBEGINNING WORK.

NO. DATE REMARKS

N

P

Q

R

12

O

1713 18161512.5

4n3.2n 5n 6n 7n 8n 9n 10n 11n 12n

B-nB-n

A-n

12.7n1.8n1n

A.7-n

D-n

E-n

13n

C-n

13.1n

A.2-n

A.4-n

8.5n

MECHANICALROOMS-005

UnoccupiedUnoccupiedWATER

HEATERS-002

ELEVATORE-1

ELEV.EQUIP.S-001

CUSTODIALS-003

CORRIDORC006

CORRIDORC-012

CA-B-1

12A

GENERAL NOTES

REFER TO SHEET COM-000 FOR SYMBOLS AND ABBREVIATIONSAND ADDITIONAL GENERAL NOTES.

FIRESTOP ALL PENETRATIONS AS REQUIRED BY CODE.

ALL SIO'S ON THIS SHEET SHALL ROUTE TO IDF ROOMS S-106, S-213, OR S-309 FOR EACH FLOOR.

COORDINATE ALL CEILING MOUNTED DEVICES WITHREFLECTED CEILING PLANS PRIOR TO ROUGH-IN.

REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OFFIRE RATED WALLS.

COORDINATE ALL SIO HEIGHTS AND LOCATIONS WITHARCHITECT/USING AGENCY AND FURNITURE LAYOUT PRIOR TOROUGH-IN. ARCHITECTURAL INTERIOR ELEVATIONS TAKEPRECEDENCE OVER HEIGHTS SHOWN ON TECHNOLOGYDRAWINGS.

REFER TO ARCHITECTURAL DRAWINGS FOR CEILINGS ANDWALL TYPES. CONFIRM CEILING AND WALL ACCESSIBILITYPROPERTIES WITH ARCHITECTURAL PLANS.

INSTALL SURFACE-MOUNTED RACEWAY OUTLETS IN DUAL-CHANNEL RACEWAY. REFER TO ELECTRICAL DRAWINGS ANDSPECIFICATIONS.

ELECTRICAL CONTRACTOR SHALL USE BUTT JOINTS FORCONNECTING CABLE RACEWAY WITH-IN IDFs. CABLE TRAYOUTSIDE OF IDF ROOM SHALL USE RADIUSED 90 DEGREEBENDS AND "T" INTERSECTIONS AS SHOWN ON FLOOR PLANS.

1.

2.

3.

4.

5.

6.

7.

8.

9.

KEY PLAN

MODULE-A

COLLEGE OF LAKE COUNTYSCIENCE ADDITION AND RENOVATIONS

19351 WEST WASHINGTON STREET, GRAYSLAKE, IL 60030

CDB PROJECT NO.

DATE

SHEET NO.

OF ( )SHEETS

810-056-025TERRA ENGINEERING, LTD.

LARSON ENGINEERING OF ILLINOIS

CONSTRUCTION COST SYSTEMS, INC.1815 SOUTH MEYERS ROAD, SUITE 200OAKBROOK TERRACE, IL 60181

225 W. OHIO STREET - 4TH FLOORCHICAGO, IL 60654

1488 BOND STREET, SUITE 100NAPERVILLE, IL 60563

CIVIL ENGINEER

STRUCTURAL ENGINEER

COST ESTIMATING

PHONE: (312) 467-0123ext: 230

PHONE: (630) 357-0540

PHONE: (630) 678-0808

CARNOW CONIBEAR

600 W. VAN BUREN - #500CHICAGO, IL 60607

ASBESTOS ABATEMENT

PHONE: (312) 762-2936

Pat Quinn, GovernorState of Illinois

Illinois Capital Development Board

PHONE: (815) 477-4545

MEPFPT ENGINEER

ARCHITECT

PHONE: (312) 977-2800

DESIGNER(312) 787-4405

REVISIONS

CHECKED APPROVED

PROJ. MNGR.

NOTE: CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AND BE FULLY RESPONSIBLE FOR SAME.

DRAWN

ARCHITECT'S PROJECT NO.

SPF

211001.00

AFFILIATED ENGINEERS, INC.

10 SOUTH LASALLE STREET, SUITE 2700CHICAGO, IL 60603

LEGAT ARCHITECTS

80 NORTH VIRGINIA STREET, SUITE CCRYSTAL LAKE, IL 60014

BRUBAKER

900 NORTH LAKESHORE DRIVE #2703CHICAGO, ILLINOIS 60611

100% BID DOCUMENTS

dbHMS

303 W. Erie Street - #510CHICAGO, IL 60654

COMMISSIONING AUTHORITY

PHONE: (312) 915-0557 ext. 258

07.21.2014

COM-200A

LOWER LEVEL SECURITY PLAN - MODULE A

CHCH

KV

07.21.2014

1/8" = 1'-0"1

LOWER LEVEL SECURITY PLAN - MODULE A

0' 4' 8' 16' 32'

NO. DATE REMARKS

FD

FD

FD

N

P

Q

R

12

O

1713 18161512.5

4n3.2n 5n 6n 7n 8n 9n 10n 11n 12n

B-n

A-n

12.7n

1.8n1n

A.7-n

D-n

E-n

13n

Room

C106

Room

C107

Room

C119

Room

C118

Room

C117

Room

C105

ATS

S-114

MAIN ELEC. ROOM

S-117

MECHATRONICSLAB

S-108

WOMEN

S-110

MEN

S-112

CONTROL ROOM

S-103

LASER LAB 3

S-104

LASER LAB 2

S-102

STAIR - S2

S-2

STAIR S-1

S-1

CA-1-1

CA-1-11CA-1-10

CR-KP

CR-KP

VI

VI

CA-1-3

ELEVATOR-2

E-1-2CUSTODIAL

S-124

GENERATOR

S-116

WOMEN SHOWER

S-111

MEN SHOWER

S-113

IDF

S-106

LASER LAB 4

S-105

LASER LAB 1

S-101

CORRIDOR

S-120

CORRIDOR

S-115

STUDENT SPACE

S-119

VESTIBULE

V-1

CORRIDOR

S-118

VESTIBULE

V-2

FACULTY OFFICE

S-107

JANITOR CLO.

S-109

C-n

13.1n

A.2-n

A.4-n

8.5n

CA-1-14

1

CA-1-7CA-1-6

CA-1-5

CA-1-1

1

CA-1-2 CA-1-4

CA-1-8 CA-1-9 CA-1-12 CA-1-13

12A

V-101D

V-102A

11n 12n 12.7n

D-n

13n 14n13.1n

CA-1-15

ROOF TOP ONALTERNATE #E-1

ALTERNATE G-1

GENERAL NOTES

REFER TO SHEET COM-000 FOR SYMBOLS AND ABBREVIATIONSAND ADDITIONAL GENERAL NOTES.

FIRESTOP ALL PENETRATIONS AS REQUIRED BY CODE.

ALL SIO'S ON THIS SHEET SHALL ROUTE TO IDF ROOMS S-106, S-213, OR S-309 FOR EACH FLOOR.

COORDINATE ALL CEILING MOUNTED DEVICES WITHREFLECTED CEILING PLANS PRIOR TO ROUGH-IN.

REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OFFIRE RATED WALLS.

COORDINATE ALL SIO HEIGHTS AND LOCATIONS WITHARCHITECT/USING AGENCY AND FURNITURE LAYOUT PRIOR TOROUGH-IN. ARCHITECTURAL INTERIOR ELEVATIONS TAKEPRECEDENCE OVER HEIGHTS SHOWN ON TECHNOLOGYDRAWINGS.

REFER TO ARCHITECTURAL DRAWINGS FOR CEILINGS ANDWALL TYPES. CONFIRM CEILING AND WALL ACCESSIBILITYPROPERTIES WITH ARCHITECTURAL PLANS.

INSTALL SURFACE-MOUNTED RACEWAY OUTLETS IN DUAL-CHANNEL RACEWAY. REFER TO ELECTRICAL DRAWINGS ANDSPECIFICATIONS.

ELECTRICAL CONTRACTOR SHALL USE BUTT JOINTS FORCONNECTING CABLE RACEWAY WITH-IN IDFs. CABLE TRAYOUTSIDE OF IDF ROOM SHALL USE RADIUSED 90 DEGREEBENDS AND "T" INTERSECTIONS AS SHOWN ON FLOOR PLANS.

1.

2.

3.

4.

5.

6.

7.

8.

9.

KEY PLAN

MODULE-A

COLLEGE OF LAKE COUNTYSCIENCE ADDITION AND RENOVATIONS

19351 WEST WASHINGTON STREET, GRAYSLAKE, IL 60030

CDB PROJECT NO.

DATE

SHEET NO.

OF ( )SHEETS

810-056-025TERRA ENGINEERING, LTD.

LARSON ENGINEERING OF ILLINOIS

CONSTRUCTION COST SYSTEMS, INC.1815 SOUTH MEYERS ROAD, SUITE 200OAKBROOK TERRACE, IL 60181

225 W. OHIO STREET - 4TH FLOORCHICAGO, IL 60654

1488 BOND STREET, SUITE 100NAPERVILLE, IL 60563

CIVIL ENGINEER

STRUCTURAL ENGINEER

COST ESTIMATING

PHONE: (312) 467-0123ext: 230

PHONE: (630) 357-0540

PHONE: (630) 678-0808

CARNOW CONIBEAR

600 W. VAN BUREN - #500CHICAGO, IL 60607

ASBESTOS ABATEMENT

PHONE: (312) 762-2936

Pat Quinn, GovernorState of Illinois

Illinois Capital Development Board

PHONE: (815) 477-4545

MEPFPT ENGINEER

ARCHITECT

PHONE: (312) 977-2800

DESIGNER(312) 787-4405

REVISIONS

CHECKED APPROVED

PROJ. MNGR.

NOTE: CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AND BE FULLY RESPONSIBLE FOR SAME.

DRAWN

ARCHITECT'S PROJECT NO.

SPF

211001.00

AFFILIATED ENGINEERS, INC.

10 SOUTH LASALLE STREET, SUITE 2700CHICAGO, IL 60603

LEGAT ARCHITECTS

80 NORTH VIRGINIA STREET, SUITE CCRYSTAL LAKE, IL 60014

BRUBAKER

900 NORTH LAKESHORE DRIVE #2703CHICAGO, ILLINOIS 60611

100% BID DOCUMENTS

dbHMS

303 W. Erie Street - #510CHICAGO, IL 60654

COMMISSIONING AUTHORITY

PHONE: (312) 915-0557 ext. 258

07.21.2014

COM-201A

FIRST FLOOR SECURITY PLAN - MODULE A

CHCH

KV

07.21.2014

1/8" = 1'-0"1

FIRST FLOOR SECURITY PLAN - MODULE A

SHEET KEYED NOTES

0' 4' 8' 16' 32'

1 CONNECT INTERCOM TO EXISTINGPOLICE DISPATCH CENTER.

1/8" = 1'-0"2

EAST CANOPY SECURITY PLAN - MODULE A

NO. DATE REMARKS

..

FD FD

FD

FD

FDFD

N

P

Q

R

12

O

1713 18161512.5

4n3.2n 5n 6n 7n 8n 9n 10n 11n 12n

B-n

A-n

12.7n

1.8n1n

A.7-n

D-n

E-n

13n

MEN

S-210

WOMEN

S-209

CHEMICALSTORAGE

S-206

STAIR S-1

S-1

IDF

S-213

WORK AREA

S-203A

STORAGE

S-203

STUDENT SPACE

S-216

BRIDGE

S-217

CORRIDOR

S-214

STUDENT SPACE

S-218

CORRIDOR

S-215

JANITOR CLO.

S-208

CART STORAGE

S-207

LAB MANAGER'SOFFICE

S-204

CORRIDOR

C220

CORRIDOR

C201ACORRIDOR

C-221

ELEVATOR

E-1

ELEC. CLOSET

S-212 FACULTY OFFICE

S-211

GLASSWASH /PREP LAB

S-205

CHEMISTRY LAB

S-202

ORGANIC CHEM.INSTR. LAB

S-201

ORGANIC CHEM.LAB

S-200

C-n

13.1n

A.2-n

A.4-n

8.5n

CA-2-3

CA-2-1

CA-2-2

CA-2-5

CA-2-4

CA-2-6 CA-2-7 CA-2-9 CA-2-9CA-2-10

CA-2-11

CA-2-23

12A

GENERAL NOTES

REFER TO SHEET COM-000 FOR SYMBOLS AND ABBREVIATIONSAND ADDITIONAL GENERAL NOTES.

FIRESTOP ALL PENETRATIONS AS REQUIRED BY CODE.

ALL SIO'S ON THIS SHEET SHALL ROUTE TO IDF ROOMS S-106, S-213, OR S-309 FOR EACH FLOOR.

COORDINATE ALL CEILING MOUNTED DEVICES WITHREFLECTED CEILING PLANS PRIOR TO ROUGH-IN.

REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OFFIRE RATED WALLS.

COORDINATE ALL SIO HEIGHTS AND LOCATIONS WITHARCHITECT/USING AGENCY AND FURNITURE LAYOUT PRIOR TOROUGH-IN. ARCHITECTURAL INTERIOR ELEVATIONS TAKEPRECEDENCE OVER HEIGHTS SHOWN ON TECHNOLOGYDRAWINGS.

REFER TO ARCHITECTURAL DRAWINGS FOR CEILINGS ANDWALL TYPES. CONFIRM CEILING AND WALL ACCESSIBILITYPROPERTIES WITH ARCHITECTURAL PLANS.

INSTALL SURFACE-MOUNTED RACEWAY OUTLETS IN DUAL-CHANNEL RACEWAY. REFER TO ELECTRICAL DRAWINGS ANDSPECIFICATIONS.

ELECTRICAL CONTRACTOR SHALL USE BUTT JOINTS FORCONNECTING CABLE RACEWAY WITH-IN IDFs. CABLE TRAYOUTSIDE OF IDF ROOM SHALL USE RADIUSED 90 DEGREEBENDS AND "T" INTERSECTIONS AS SHOWN ON FLOOR PLANS.

1.

2.

3.

4.

5.

6.

7.

8.

9.

KEY PLAN

MODULE-A

COLLEGE OF LAKE COUNTYSCIENCE ADDITION AND RENOVATIONS

19351 WEST WASHINGTON STREET, GRAYSLAKE, IL 60030

CDB PROJECT NO.

DATE

SHEET NO.

OF ( )SHEETS

810-056-025TERRA ENGINEERING, LTD.

LARSON ENGINEERING OF ILLINOIS

CONSTRUCTION COST SYSTEMS, INC.1815 SOUTH MEYERS ROAD, SUITE 200OAKBROOK TERRACE, IL 60181

225 W. OHIO STREET - 4TH FLOORCHICAGO, IL 60654

1488 BOND STREET, SUITE 100NAPERVILLE, IL 60563

CIVIL ENGINEER

STRUCTURAL ENGINEER

COST ESTIMATING

PHONE: (312) 467-0123ext: 230

PHONE: (630) 357-0540

PHONE: (630) 678-0808

CARNOW CONIBEAR

600 W. VAN BUREN - #500CHICAGO, IL 60607

ASBESTOS ABATEMENT

PHONE: (312) 762-2936

Pat Quinn, GovernorState of Illinois

Illinois Capital Development Board

PHONE: (815) 477-4545

MEPFPT ENGINEER

ARCHITECT

PHONE: (312) 977-2800

DESIGNER(312) 787-4405

REVISIONS

CHECKED APPROVED

PROJ. MNGR.

NOTE: CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CO NDITIONS AT JOB SITE AND BE FULLY RESPONSIBLE FOR S AME.

DRAWN

ARCHITECT'S PROJECT NO.

SPF

211001.00

AFFILIATED ENGINEERS, INC.

10 SOUTH LASALLE STREET, SUITE 2700CHICAGO, IL 60603

LEGAT ARCHITECTS

80 NORTH VIRGINIA STREET, SUITE CCRYSTAL LAKE, IL 60014

BRUBAKER

900 NORTH LAKESHORE DRIVE #2703CHICAGO, ILLINOIS 60611

100% BID DOCUMENTS

dbHMS

303 W. Erie Street - #510CHICAGO, IL 60654

COMMISSIONING AUTHORITY

PHONE: (312) 915-0557 ext. 258

07.21.2014

COM-202A

SECOND FLOOR SECURITY PLAN - MODULE A

CHCH

KV

07.21.2014

1/8" = 1'-0"1

SECOND FLOOR SECURITY PLAN - MODULE A

0' 4' 8' 16' 32'

NO. DATE REMARKS

DN

DN

..

. .

DN

FD FD

A1

C

F.3

H

J

L

N

EM

EK

EJ.8

EH

EE

EF

1 42 7 10 12

O

5.7

17

3 6 11 13

1816.21615.915.715

12.57.55

15.8

4n3.2n 5n 6n1.8n1n

E-n

A & P LAB 1

C-201

CADAVER LAB 1

C-201A

CADAVER LAB 2

C-202A

GLASSWASH

B-232B

CLASSROOM

B-219

EQUIP. STORAGE

B-232C

MEDIA PREP

B-232A

MICROBIOLOGYLAB 2

B-231

PREP

B-232

A & P LAB 2

C-202

A & P LAB 1

C-201

MICROBIOLOGYLAB 1

B-218

PREP/STAGING

C-203

BRIDGE

S-217

CORRIDOR-1

B226H-1

CORRIDOR-2

B226H-2

CORRIDOR-1

B223-1

CORRIDOR-2

B223-2

CORRIDOR

C201ACORRIDOR

C-221

CA-2-15

CA-2-16

CA-2-18

CA-2-17

CA-2-19

CA-2-20

CA-2-13

CA-2-14

CA-2-12 CA-2-21

M

K

J.8

G

F

E

B1

C1

D1

D

12A

9GENERAL NOTES

REFER TO SHEET COM-000 FOR SYMBOLS AND ABBREVIATIONSAND ADDITIONAL GENERAL NOTES.

FIRESTOP ALL PENETRATIONS AS REQUIRED BY CODE.

ALL SIO'S ON THIS SHEET SHALL ROUTE TO IDF ROOMS S-106, S-213, OR S-309 FOR EACH FLOOR.

COORDINATE ALL CEILING MOUNTED DEVICES WITHREFLECTED CEILING PLANS PRIOR TO ROUGH-IN.

REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OFFIRE RATED WALLS.

COORDINATE ALL SIO HEIGHTS AND LOCATIONS WITHARCHITECT/USING AGENCY AND FURNITURE LAYOUT PRIOR TOROUGH-IN. ARCHITECTURAL INTERIOR ELEVATIONS TAKEPRECEDENCE OVER HEIGHTS SHOWN ON TECHNOLOGYDRAWINGS.

REFER TO ARCHITECTURAL DRAWINGS FOR CEILINGS ANDWALL TYPES. CONFIRM CEILING AND WALL ACCESSIBILITYPROPERTIES WITH ARCHITECTURAL PLANS.

INSTALL SURFACE-MOUNTED RACEWAY OUTLETS IN DUAL-CHANNEL RACEWAY. REFER TO ELECTRICAL DRAWINGS ANDSPECIFICATIONS.

ELECTRICAL CONTRACTOR SHALL USE BUTT JOINTS FORCONNECTING CABLE RACEWAY WITH-IN IDFs. CABLE TRAYOUTSIDE OF IDF ROOM SHALL USE RADIUSED 90 DEGREEBENDS AND "T" INTERSECTIONS AS SHOWN ON FLOOR PLANS.

1.

2.

3.

4.

5.

6.

7.

8.

9.

KEY PLAN

MO

DU

LE-B

COLLEGE OF LAKE COUNTYSCIENCE ADDITION AND RENOVATIONS

19351 WEST WASHINGTON STREET, GRAYSLAKE, IL 60030

CDB PROJECT NO.

DATE

SHEET NO.

OF ( )SHEETS

810-056-025TERRA ENGINEERING, LTD.

LARSON ENGINEERING OF ILLINOIS

CONSTRUCTION COST SYSTEMS, INC.1815 SOUTH MEYERS ROAD, SUITE 200OAKBROOK TERRACE, IL 60181

225 W. OHIO STREET - 4TH FLOORCHICAGO, IL 60654

1488 BOND STREET, SUITE 100NAPERVILLE, IL 60563

CIVIL ENGINEER

STRUCTURAL ENGINEER

COST ESTIMATING

PHONE: (312) 467-0123ext: 230

PHONE: (630) 357-0540

PHONE: (630) 678-0808

CARNOW CONIBEAR

600 W. VAN BUREN - #500CHICAGO, IL 60607

ASBESTOS ABATEMENT

PHONE: (312) 762-2936

Pat Quinn, GovernorState of Illinois

Illinois Capital Development Board

PHONE: (815) 477-4545

MEPFPT ENGINEER

ARCHITECT

PHONE: (312) 977-2800

DESIGNER(312) 787-4405

REVISIONS

CHECKED APPROVED

PROJ. MNGR.

NOTE: CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AND BE FULLY RESPONSIBLE FOR SAME.

DRAWN

ARCHITECT'S PROJECT NO.

SPF

211001.00

AFFILIATED ENGINEERS, INC.

10 SOUTH LASALLE STREET, SUITE 2700CHICAGO, IL 60603

LEGAT ARCHITECTS

80 NORTH VIRGINIA STREET, SUITE CCRYSTAL LAKE, IL 60014

BRUBAKER

900 NORTH LAKESHORE DRIVE #2703CHICAGO, ILLINOIS 60611

100% BID DOCUMENTS

dbHMS

303 W. Erie Street - #510CHICAGO, IL 60654

COMMISSIONING AUTHORITY

PHONE: (312) 915-0557 ext. 258

07.21.2014

COM-202B

SECOND FLOOR SECURITY PLAN - MODULE B

CHCH

KV

07.21.2014

1/8" = 1'-0"1

SECOND FLOOR SECURITY PLAN - MODULE B

0' 4' 8' 16' 32'

NO. DATE REMARKS

DN

DN

ICE

RE

F

.R

EF

RE

FR

EF

RE

F

RE

F

. ..

DN

DN

FD

. ..

N

1 2.1 42

PQ

R

S

U

V

7 10 12

O

W5.75.3

3 6 11 1312.57.55

B-n

A-n

1n

A.7-n

D-n

E-n

CLASSROOM

C-233

ENVIRONMENTALBIO / CONCEPTS

LAB

C-222

BIOLOGY LAB

C-223

BIOLOGY LAB

C-224

BIOLOGY 2 /ZOOLOGY / STEM

LAB

C-225

CORRIDOR

C-235

STUDENT SPACE

S-216

CORRIDOR

C220

CORRIDOR

C221

LIVEANIMAL

STORAGE

C-228GREENHOUSE

C-226

STORAGE

C-229

BIOLOGYPREP

C-230

BIOLOGYMULTI-USESUPPORT

C-227

OFFICE

C-231

C-n

A.2-n

A.4-n

ALTERNATE #E-3

NIC

CA-2-24

CA-2-23

CA-2-22

T

9

1 2.1 42

S

U

V

5.75.3

ALTERNATE #E-2

NICGREENHOUSE

C-226

ORGANISMSTORAGE

C-227

BIOLOGYSTORAGE

C-228

PREP&

GLASSWASH

C-230

COLLECTIONS

C-229

WORKROOM

C-231

LABMANAGER

C-232

STORAGE

C-228A

T

GENERAL NOTES

REFER TO SHEET COM-000 FOR SYMBOLS AND ABBREVIATIONSAND ADDITIONAL GENERAL NOTES.

FIRESTOP ALL PENETRATIONS AS REQUIRED BY CODE.

ALL SIO'S ON THIS SHEET SHALL ROUTE TO IDF ROOMS S-106, S-213, OR S-309 FOR EACH FLOOR.

COORDINATE ALL CEILING MOUNTED DEVICES WITHREFLECTED CEILING PLANS PRIOR TO ROUGH-IN.

REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OFFIRE RATED WALLS.

COORDINATE ALL SIO HEIGHTS AND LOCATIONS WITHARCHITECT/USING AGENCY AND FURNITURE LAYOUT PRIOR TOROUGH-IN. ARCHITECTURAL INTERIOR ELEVATIONS TAKEPRECEDENCE OVER HEIGHTS SHOWN ON TECHNOLOGYDRAWINGS.

REFER TO ARCHITECTURAL DRAWINGS FOR CEILINGS ANDWALL TYPES. CONFIRM CEILING AND WALL ACCESSIBILITYPROPERTIES WITH ARCHITECTURAL PLANS.

INSTALL SURFACE-MOUNTED RACEWAY OUTLETS IN DUAL-CHANNEL RACEWAY. REFER TO ELECTRICAL DRAWINGS ANDSPECIFICATIONS.

ELECTRICAL CONTRACTOR SHALL USE BUTT JOINTS FORCONNECTING CABLE RACEWAY WITH-IN IDFs. CABLE TRAYOUTSIDE OF IDF ROOM SHALL USE RADIUSED 90 DEGREEBENDS AND "T" INTERSECTIONS AS SHOWN ON FLOOR PLANS.

1.

2.

3.

4.

5.

6.

7.

8.

9.

KEY PLANMOD

ULE

-C

COLLEGE OF LAKE COUNTYSCIENCE ADDITION AND RENOVATIONS

19351 WEST WASHINGTON STREET, GRAYSLAKE, IL 60030

CDB PROJECT NO.

DATE

SHEET NO.

OF ( )SHEETS

810-056-025TERRA ENGINEERING, LTD.

LARSON ENGINEERING OF ILLINOIS

CONSTRUCTION COST SYSTEMS, INC.1815 SOUTH MEYERS ROAD, SUITE 200OAKBROOK TERRACE, IL 60181

225 W. OHIO STREET - 4TH FLOORCHICAGO, IL 60654

1488 BOND STREET, SUITE 100NAPERVILLE, IL 60563

CIVIL ENGINEER

STRUCTURAL ENGINEER

COST ESTIMATING

PHONE: (312) 467-0123ext: 230

PHONE: (630) 357-0540

PHONE: (630) 678-0808

CARNOW CONIBEAR

600 W. VAN BUREN - #500CHICAGO, IL 60607

ASBESTOS ABATEMENT

PHONE: (312) 762-2936

Pat Quinn, GovernorState of Illinois

Illinois Capital Development Board

PHONE: (815) 477-4545

MEPFPT ENGINEER

ARCHITECT

PHONE: (312) 977-2800

DESIGNER(312) 787-4405

REVISIONS

CHECKED APPROVED

PROJ. MNGR.

NOTE: CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AND BE FULLY RESPONSIBLE FOR SAME.

DRAWN

ARCHITECT'S PROJECT NO.

SPF

211001.00

AFFILIATED ENGINEERS, INC.

10 SOUTH LASALLE STREET, SUITE 2700CHICAGO, IL 60603

LEGAT ARCHITECTS

80 NORTH VIRGINIA STREET, SUITE CCRYSTAL LAKE, IL 60014

BRUBAKER

900 NORTH LAKESHORE DRIVE #2703CHICAGO, ILLINOIS 60611

100% BID DOCUMENTS

dbHMS

303 W. Erie Street - #510CHICAGO, IL 60654

COMMISSIONING AUTHORITY

PHONE: (312) 915-0557 ext. 258

07.21.2014

COM-202C

SECOND FLOOR SECURITY PLAN - MODULE C

CHCH

KV

07.21.2014

1/8" = 1'-0"1

SECOND FLOOR SECURITY PLAN - MODULE C

0' 2' 4' 8' 16'

1/8" = 1'-0"2

SECOND FLOOR SECURITY PLAN - MODULE C ALTERNATE 2

NO. DATE REMARKS

.FD

FD

FD FD FDFD

N

PQ

R

12

O

1713 18161512.5

4n3.2n 5n 6n 7n 8n 9n 10n 11n 12n

B-n

A-n

12.7n

1.8n1n

A.7-n

D-n

E-n

13n

WOMEN

S-305

MEN

S-306

STAIR S-1

S-1

IDF

S-309

CORRIDOR

S-313

CORRIDOR

S-312

JANITOR CLO.

S-310

CART STORAGE

S-311ELEVATOR-4

E-1-4

DRY STORAGE

S-304

FACULTY OFFICE

S-307

ELEC. CLOSET

S-308 CHEMISTRY LAB

S-303

CHEMISTRY LAB

S-302INSTRUMENT LAB

S-301

CHEMISTRY LAB

S-300

C-n

13.1n8.5n

CA-3-1

CA-3-4 CA-3-6

CA-3-7

CA-3-3

CA-3-2

CA-3-5

12A

GENERAL NOTES

REFER TO SHEET COM-000 FOR SYMBOLS AND ABBREVIATIONSAND ADDITIONAL GENERAL NOTES.

FIRESTOP ALL PENETRATIONS AS REQUIRED BY CODE.

ALL SIO'S ON THIS SHEET SHALL ROUTE TO IDF ROOMS S-106, S-213, OR S-309 FOR EACH FLOOR.

COORDINATE ALL CEILING MOUNTED DEVICES WITHREFLECTED CEILING PLANS PRIOR TO ROUGH-IN.

REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OFFIRE RATED WALLS.

COORDINATE ALL SIO HEIGHTS AND LOCATIONS WITHARCHITECT/USING AGENCY AND FURNITURE LAYOUT PRIOR TOROUGH-IN. ARCHITECTURAL INTERIOR ELEVATIONS TAKEPRECEDENCE OVER HEIGHTS SHOWN ON TECHNOLOGYDRAWINGS.

REFER TO ARCHITECTURAL DRAWINGS FOR CEILINGS ANDWALL TYPES. CONFIRM CEILING AND WALL ACCESSIBILITYPROPERTIES WITH ARCHITECTURAL PLANS.

INSTALL SURFACE-MOUNTED RACEWAY OUTLETS IN DUAL-CHANNEL RACEWAY. REFER TO ELECTRICAL DRAWINGS ANDSPECIFICATIONS.

ELECTRICAL CONTRACTOR SHALL USE BUTT JOINTS FORCONNECTING CABLE RACEWAY WITH-IN IDFs. CABLE TRAYOUTSIDE OF IDF ROOM SHALL USE RADIUSED 90 DEGREEBENDS AND "T" INTERSECTIONS AS SHOWN ON FLOOR PLANS.

1.

2.

3.

4.

5.

6.

7.

8.

9.

KEY PLAN

MODULE-A

COLLEGE OF LAKE COUNTYSCIENCE ADDITION AND RENOVATIONS

19351 WEST WASHINGTON STREET, GRAYSLAKE, IL 60030

CDB PROJECT NO.

DATE

SHEET NO.

OF ( )SHEETS

810-056-025TERRA ENGINEERING, LTD.

LARSON ENGINEERING OF ILLINOIS

CONSTRUCTION COST SYSTEMS, INC.1815 SOUTH MEYERS ROAD, SUITE 200OAKBROOK TERRACE, IL 60181

225 W. OHIO STREET - 4TH FLOORCHICAGO, IL 60654

1488 BOND STREET, SUITE 100NAPERVILLE, IL 60563

CIVIL ENGINEER

STRUCTURAL ENGINEER

COST ESTIMATING

PHONE: (312) 467-0123ext: 230

PHONE: (630) 357-0540

PHONE: (630) 678-0808

CARNOW CONIBEAR

600 W. VAN BUREN - #500CHICAGO, IL 60607

ASBESTOS ABATEMENT

PHONE: (312) 762-2936

Pat Quinn, GovernorState of Illinois

Illinois Capital Development Board

PHONE: (815) 477-4545

MEPFPT ENGINEER

ARCHITECT

PHONE: (312) 977-2800

DESIGNER(312) 787-4405

REVISIONS

CHECKED APPROVED

PROJ. MNGR.

NOTE: CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AND BE FULLY RESPONSIBLE FOR SAME.

DRAWN

ARCHITECT'S PROJECT NO.

SPF

211001.00

AFFILIATED ENGINEERS, INC.

10 SOUTH LASALLE STREET, SUITE 2700CHICAGO, IL 60603

LEGAT ARCHITECTS

80 NORTH VIRGINIA STREET, SUITE CCRYSTAL LAKE, IL 60014

BRUBAKER

900 NORTH LAKESHORE DRIVE #2703CHICAGO, ILLINOIS 60611

100% BID DOCUMENTS

dbHMS

303 W. Erie Street - #510CHICAGO, IL 60654

COMMISSIONING AUTHORITY

PHONE: (312) 915-0557 ext. 258

07.21.2014

COM-203A

THIRD FLOOR SECURITY PLAN - MODULE A

CHCH

KV

07.21.2014

1/8" = 1'-0"1

THIRD FLOOR SECURITY PLAN - MODULE A

0' 4' 8' 16' 32'

NO. DATE REMARKS

12.5

4n3.2n 5n 6n 7n 8n 9n 10n 11n 12n

B-n

A-n

12.7n1.8n1n

A.7-n

D-n

E-n

13n

MECHANICALPENTHOUSE

S-PH-400

C-n

13.1n8.5n

CA-4-1

CA-4-2 CA-4-3

CA-4-4

GENERAL NOTES

REFER TO SHEET COM-000 FOR SYMBOLS AND ABBREVIATIONSAND ADDITIONAL GENERAL NOTES.

FIRESTOP ALL PENETRATIONS AS REQUIRED BY CODE.

ALL SIO'S ON THIS SHEET SHALL ROUTE TO IDF ROOMS S-106, S-213, OR S-309 FOR EACH FLOOR.

COORDINATE ALL CEILING MOUNTED DEVICES WITHREFLECTED CEILING PLANS PRIOR TO ROUGH-IN.

REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OFFIRE RATED WALLS.

COORDINATE ALL SIO HEIGHTS AND LOCATIONS WITHARCHITECT/USING AGENCY AND FURNITURE LAYOUT PRIOR TOROUGH-IN. ARCHITECTURAL INTERIOR ELEVATIONS TAKEPRECEDENCE OVER HEIGHTS SHOWN ON TECHNOLOGYDRAWINGS.

REFER TO ARCHITECTURAL DRAWINGS FOR CEILINGS ANDWALL TYPES. CONFIRM CEILING AND WALL ACCESSIBILITYPROPERTIES WITH ARCHITECTURAL PLANS.

INSTALL SURFACE-MOUNTED RACEWAY OUTLETS IN DUAL-CHANNEL RACEWAY. REFER TO ELECTRICAL DRAWINGS ANDSPECIFICATIONS.

ELECTRICAL CONTRACTOR SHALL USE BUTT JOINTS FORCONNECTING CABLE RACEWAY WITH-IN IDFs. CABLE TRAYOUTSIDE OF IDF ROOM SHALL USE RADIUSED 90 DEGREEBENDS AND "T" INTERSECTIONS AS SHOWN ON FLOOR PLANS.

1.

2.

3.

4.

5.

6.

7.

8.

9.

KEY PLAN

MODULE-A

COLLEGE OF LAKE COUNTYSCIENCE ADDITION AND RENOVATIONS

19351 WEST WASHINGTON STREET, GRAYSLAKE, IL 60030

CDB PROJECT NO.

DATE

SHEET NO.

OF ( )SHEETS

810-056-025TERRA ENGINEERING, LTD.

LARSON ENGINEERING OF ILLINOIS

CONSTRUCTION COST SYSTEMS, INC.1815 SOUTH MEYERS ROAD, SUITE 200OAKBROOK TERRACE, IL 60181

225 W. OHIO STREET - 4TH FLOORCHICAGO, IL 60654

1488 BOND STREET, SUITE 100NAPERVILLE, IL 60563

CIVIL ENGINEER

STRUCTURAL ENGINEER

COST ESTIMATING

PHONE: (312) 467-0123ext: 230

PHONE: (630) 357-0540

PHONE: (630) 678-0808

CARNOW CONIBEAR

600 W. VAN BUREN - #500CHICAGO, IL 60607

ASBESTOS ABATEMENT

PHONE: (312) 762-2936

Pat Quinn, GovernorState of Illinois

Illinois Capital Development Board

PHONE: (815) 477-4545

MEPFPT ENGINEER

ARCHITECT

PHONE: (312) 977-2800

DESIGNER(312) 787-4405

REVISIONS

CHECKED APPROVED

PROJ. MNGR.

NOTE: CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AND BE FULLY RESPONSIBLE FOR SAME.

DRAWN

ARCHITECT'S PROJECT NO.

SPF

211001.00

AFFILIATED ENGINEERS, INC.

10 SOUTH LASALLE STREET, SUITE 2700CHICAGO, IL 60603

LEGAT ARCHITECTS

80 NORTH VIRGINIA STREET, SUITE CCRYSTAL LAKE, IL 60014

BRUBAKER

900 NORTH LAKESHORE DRIVE #2703CHICAGO, ILLINOIS 60611

100% BID DOCUMENTS

dbHMS

303 W. Erie Street - #510CHICAGO, IL 60654

COMMISSIONING AUTHORITY

PHONE: (312) 915-0557 ext. 258

07.21.2014

COM-204A

PENTHOUSE SECURITY PLAN - MODULE A

CHCH

KV

07.21.2014

1/8" = 1'-0"1

PENTHOUSE SECURITY PLAN - MODULE A

0' 4' 8' 16' 32'

NO. DATE REMARKS

10n

C-n

A.7-n

C.1-n

10n

B-n

A.7-n

C-n

A.4-n

12" W CABLE RUNWAY (TYP.)

(3) 4" CONDUIT SLEEVES (TYP.)

ABC

FLOOR STANDINGEQUIPMENT RACK (TYP.)

VERTICAL CABLEMANAGER (TYP.)

COM-400

5

CABLE TRAY OUTSIDEOF IDF ROOM (TYP.)

CABLE RUNWAY(TYP.)

50 PAIR TERMINATION BLOCK(TYP.)

TGB

3.2n

A.7-n

2.4n 3.2n

A.7-n

A.4-n

A B C D

COM-400

3

CABLE TRAY OUTSIDEOF IDF ROOM (TYP.)

4" CONDUITSLEEVES (TYP.)

2-POSTRACK(TYP.)

CABLE RUNWAY(TYP.)

VERTICAL CABLEMANAGER(TYP.)

4" CONDUIT FLOORSLEEVE(TYP.)

50 PAIR TERMINATION BLOCK(TYP.)

TGB

3.2n

A.7-n

2.4n 3.2n

A.7-n

A B C D

COM-400

1

CABLE TRAY OUTSIDEOF IDF ROOM (TYP.)

4" CONDUITSLEEVES (TYP.)

2-POSTRACK(TYP.)

CABLE RUNWAY(TYP.)

VERTICAL CABLEMANAGER(TYP.)

4" CONDUIT FLOORSLEEVE(TYP.)

50 PAIR TERMINATION BLOCK(TYP.)

TGB

GENERAL NOTES

REFER TO SHEET COM-000 FOR SYMBOLS AND ABBREVIATIONSAND ADDITIONAL GENERAL NOTES.

FIRESTOP ALL PENETRATIONS AS REQUIRED BY CODE.

ALL SIO'S ON THIS SHEET SHALL ROUTE TO IDF ROOMS S-106, S-213, OR S-309 FOR EACH FLOOR.

COORDINATE ALL CEILING MOUNTED DEVICES WITHREFLECTED CEILING PLANS PRIOR TO ROUGH-IN.

REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OFFIRE RATED WALLS.

COORDINATE ALL SIO HEIGHTS AND LOCATIONS WITHARCHITECT/USING AGENCY AND FURNITURE LAYOUT PRIOR TOROUGH-IN. ARCHITECTURAL INTERIOR ELEVATIONS TAKEPRECEDENCE OVER HEIGHTS SHOWN ON TECHNOLOGYDRAWINGS.

REFER TO ARCHITECTURAL DRAWINGS FOR CEILINGS ANDWALL TYPES. CONFIRM CEILING AND WALL ACCESSIBILITYPROPERTIES WITH ARCHITECTURAL PLANS.

INSTALL SURFACE-MOUNTED RACEWAY OUTLETS IN DUAL-CHANNEL RACEWAY. REFER TO ELECTRICAL DRAWINGS ANDSPECIFICATIONS.

ELECTRICAL CONTRACTOR SHALL USE BUTT JOINTS FORCONNECTING CABLE RACEWAY WITH-IN IDFs. CABLE TRAYOUTSIDE OF IDF ROOM SHALL USE RADIUSED 90 DEGREEBENDS AND "T" INTERSECTIONS AS SHOWN ON FLOOR PLANS.

1.

2.

3.

4.

5.

6.

7.

8.

9.

GROUND BAR(TYP.)

2RU HORIZONTALCABLE MANAGER(TYP.)

48 PORT PATCHPANEL DATATERMINATIONS(TYP.)

SPACE RESERVED FORUSING AGENCYNETWORK ELECTRONICS

FIBER OPTICBACKBONEPATCH PANEL

C B A

2RU HORIZONTALCABLE MANAGER(TYP.)

48 PORT PATCHPANEL FOR WAPTERMINATIONS(TYP.)

48 PORT PATCHPANEL FOR SECURITYCAMERA TERMINATIONS(TYP.)

SPACE RESERVED FORUSING AGENCYNETWORK ELECTRONICS

FIBER OPTICBACKBONEPATCH PANEL

GROUND BAR(TYP.)

2RU HORIZONTALCABLE MANAGER(TYP.)

48 PORT PATCHPANEL FOR VOICE/DATATERMINATIONS(TYP.)

A B C D

48 PORT CAT 6PATCH PANELFOR WAP TERMINATIONS

48 PORT CAT 6PATCH PANELFOR SECURITY CAMERATERMINATIONS

SPACE RESERVED FORUSING AGENCYNETWORK ELECTRONICS

FIBER OPTICBACKBONEPATCH PANEL

TGB

A B C D

GROUND BAR(TYP.)

2RU HORIZONTALCABLE MANAGER(TYP.)

48 PORT PATCHPANEL FOR DATATERMINATIONS(TYP.)

2RU HORIZONTALCABLE MANAGER(TYP.)

48 PORT PATCHPANEL FOR WAPTERMINATIONS(TYP.)

48 PORT PATCHPANEL FOR SECURITYCAMERATERMINATIONS(TYP.)

COLLEGE OF LAKE COUNTYSCIENCE ADDITION AND RENOVATIONS

19351 WEST WASHINGTON STREET, GRAYSLAKE, IL 60030

CDB PROJECT NO.

DATE

SHEET NO.

OF ( )SHEETS

810-056-025TERRA ENGINEERING, LTD.

LARSON ENGINEERING OF ILLINOIS

CONSTRUCTION COST SYSTEMS, INC.1815 SOUTH MEYERS ROAD, SUITE 200OAKBROOK TERRACE, IL 60181

225 W. OHIO STREET - 4TH FLOORCHICAGO, IL 60654

1488 BOND STREET, SUITE 100NAPERVILLE, IL 60563

CIVIL ENGINEER

STRUCTURAL ENGINEER

COST ESTIMATING

PHONE: (312) 467-0123ext: 230

PHONE: (630) 357-0540

PHONE: (630) 678-0808

CARNOW CONIBEAR

600 W. VAN BUREN - #500CHICAGO, IL 60607

ASBESTOS ABATEMENT

PHONE: (312) 762-2936

Pat Quinn, GovernorState of Illinois

Illinois Capital Development Board

PHONE: (815) 477-4545

MEPFPT ENGINEER

ARCHITECT

PHONE: (312) 977-2800

DESIGNER(312) 787-4405

REVISIONS

CHECKED APPROVED

PROJ. MNGR.

NOTE: CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AND BE FULLY RESPONSIBLE FOR SAME.

DRAWN

ARCHITECT'S PROJECT NO.

SPF

211001.00

AFFILIATED ENGINEERS, INC.

10 SOUTH LASALLE STREET, SUITE 2700CHICAGO, IL 60603

LEGAT ARCHITECTS

80 NORTH VIRGINIA STREET, SUITE CCRYSTAL LAKE, IL 60014

BRUBAKER

900 NORTH LAKESHORE DRIVE #2703CHICAGO, ILLINOIS 60611

100% BID DOCUMENTS

dbHMS

303 W. Erie Street - #510CHICAGO