4
1. Unpacking and Checking NIX-41 (0.5U) 2. NIX Ports Description 3. System Application—1+0 4. System Application—1+1 / 2+0 4. System Application—1+1 SD NIX Quick Installation Guide NIX-43 (0.5U and 1U) Check the accessories against the packing list. *Coupler for 1+1 or 2+0 system; OMT for 2+0 system. ODU ODU GND TDM Interface 2xSTM-1 Single Mode SFP TDM Interface 2x16xE1/T1 MDR68 External Clock 2048Kbits NCX GigE Electrical 4x10/100/1000 Base-T RJ-45 GigE SFP 3x1000 Base-X Single Mode SFP CIT RJ-45 AUX/Alarm RJ-45 IF Interface TNC XPIC MCX Power Switch Power Interface -48VDC GND LPC Antenna LPC Antenna IP Data + NMS LPC Antenna LPC Antenna IF Cable IF Cable ODU ODU ODU ODU Lightning Arrester Lightning Arrester IP Data + NMS

Comba-NIX Microwave radio Quick Installation Guide 072014

  • Upload
    reza

  • View
    159

  • Download
    25

Embed Size (px)

DESCRIPTION

in this file you can fine the installation manual of Comba NIX microwave radio

Citation preview

  • 1. Unpacking and Checking

    NIX-41 (0.5U)

    2. NIX Ports Description

    3. System Application1+0

    4. System Application1+1 / 2+0

    4. System Application1+1 SD

    NIX Quick Installation Guide

    NIX-43 (0.5U and 1U)

    Check the accessories against the packing list.

    *Coupler for 1+1 or 2+0 system; OMT for 2+0 system.

    OD

    U

    O

    D

    U

    GND

    TDM Interface2xSTM-1Single Mode SFP

    TDM Interface2x16xE1/T1MDR68

    External Clock2048KbitsNCX

    GigE Electrical4x10/100/1000 Base-TRJ-45

    GigE SFP3x1000 Base-X Single Mode SFP

    CITRJ-45

    AUX/AlarmRJ-45

    IF InterfaceTNC

    XPICMCX

    Power Switch

    Power Interface-48VDC

    GND

    LPCAntenna

    LPCAntenna

    IP Data + NMS

    LPCAntenna

    LPCAntenna

    IF Cable

    IF Cable

    OD

    UO

    DU

    O

    D

    U

    O

    D

    U

    Lightning Arrester

    Lightning Arrester

    IP Data + NMS

  • Power Supply Cable

    GND Cable

    IF Jumper

    IF Cable

    SFP Module

    Electrical SFP Module

    Optical SFP Module

    Installing SFP ModuleRemoving SFP Module

    E1 Cable

    PSU

    Power Supply Unit

    -48V

    Lightning Arrester

    GND Cable

    5. Cable Connection 6. Antenna Alignment Preparation

    NIX Quick Installation Guide

    Installing SFP Module 1. Wear an ESD-preventive wrist strap before SFP module

    installation. 2. Find the send (TX) and receive (RX) markings that iden-

    tify the top side of the SFP transceiver module. 3. Position the SFP transceiver module in front of the

    socket opening.

    Please refer to the antenna and ODU installation guide for installation instruc-tions of antenna and ODU.

    NOTE: Dont switch on the power until all the cables are installed properly.

    For the specific operating frequency of the hop, arrange to enable the RSL to become variable within an al-lowable range, correlate the data in the lookup table against the RSSI reading along all points of the RSL range. The antenna pair is identified when measured RSSI level matches against the corresponding RSL values

    The above figure represents the RSSI level as the antenna is being brought into alignment. Location of the optimal signal strength should be at the maxi-mum of its RSSI profile.

    RSL (dBm) -20

    -25 -30 -35 -40 -45 -50 -55 -60 -65 -70 -75 -80 -85

    Vbnc (V) 4.50 4.19 3.87 3.56 3.25 2.94 2.65 2.31 2.0 1.69 1.37 1.06 0.75 0.44

    6. Antenna Alignment

    Disable the ATPC func-t ion.

    Cl ick to save changes.

    Cl ick to undo any changes made local ly and revert to previously saved values.

    Go to Configuration>MRU > ODU

    Set the TX Frequency to the Max. Value.

    Please refer to the NIX User Manual for the detai ls of log in System Configuration Web Interface.

  • 6. System Configuration System Mode (1)

    NIX Quick Installation Guide

    Go to Configuration>MRU >System>ODU IP. Configure the System Mode .

    Cl ick to save changes.

    6. System Configuration Modem (2)

    Modem Configuration in 1+0 System Mode

    Click to undo any changes made local ly and revert to previously saved values.

    Modem Configuration in 2+0 System Mode 6. System Configuration Modem (2)

    NOTE: The traf f ic parameters sett ing vary according to the traf f ic type.

    Traffic / Parameters E1 Enable STM-1 Enable

    IP Disable Disable IP+16E1 Enable Disable IP+16E1+STM-1 Enable Enable

    IP+STM-1 Disable Enable

    6. System Configuration Traffic (3)

    Go to Configuration > MSU > E1.

    Go to Configuration > MRU > Modem.

    Configure the parameters as table below.

    ACM Switch Off Modulation Mode 256QAM

    Bandwidth 56MHz

    XPIC NoXPIC

    MASTER Mode Single

    1. MRU Modem Conf igurat ion

    2. SRU Modem Conf igurat ion

    Go to Configuration > SRU > Modem.

    Configure the parameters as table below.

    ACM Switch Off Modulation Mode 256QAM

    Bandwidth 56MHz

    XPIC NoXPIC

    MASTER Mode Single

    Go to Configuration > MRU > Modem.

    Configure the parameters as table below.

    1. MRU Modem Conf igurat ion

    2. SRU Modem Conf igurat ion

    Go to Configuration > SRU > Modem.

    Configure the parameters as table below.

    ACM Switch Off Modulation Mode 256QAM

    Bandwidth 56MHz

    XPIC NoXPIC (no XPIC ) / XPIC (with XPIC ) MASTER Mode Slave

    ACM Switch Off Modulation Mode 256QAM

    Bandwidth 56MHz

    XPIC NoXPIC (no XPIC ) / XPIC (with XPIC ) MASTER Mode Master

  • 6. System Configuration Synch Ethernet (4)

    NIX Quick Installation Guide

    6. System Configuration 1588V2 (5)

    6. System Configuration IP Address (6)

    1. Go to Configuration > Switch > PTP. 2. Cl ick Add New PTP Clock , and then set up Device Type as E2e Transp . 3. Configure 2 Step Flag . True refers to xxxx, False refers to xxxx. 4. Configure Protocol . Ethernet refers to two layer mult icast , IPV4 Mult i refers to

    three layer mult icast, IPV4 Uni means three layer unicast . 5. Cl ick Save to accept the conf igurat ion. 6. Check the port to which the Synch Ethernet connect and port 9, then c l ick Save . 7. Set up PTP Master Enable as True , then c l ick Save .

    Go to Configuration > Switch > SyncE. I f the Synch Ethernet funct ion is not required, uncheck the c lock port .

    I f the Synch Ethernet funct ion is required, f i rst ly ident i fy the port to which the Synch Ethernet connect for upstream equipment, then check the desired port in both Port Configuration ( Configuration > Switch > Port) window and SyncE Configuration window.

    Check the port 9 in SyncE Configuration window for downstream equipment.

    Upstream Equipment Configuration

    Downstream Equipment Configuration ( Fol low steps 1-6 above to f in ish the downstream equipment conf igurat ion) .

    Go to Configuration > MRU > IDU IP to set up the IP address for both s ides.

    NOTE: After the system configuration above f inished, reboot the equipments for the changes to take effect.