COMMERCIALPERMITSExpedited Permit ProcessThe following submittals are required to
qualify for expedited permit process
SUBMITTAL REQUIREMENTSA permit application signed & notarized and 2 copies of the below stated documents must be submitted for review.
PERMIT TYPES
EXCLUSIONS - To following conditions must apply in order to qualify for the Expedited Permit Process 1. There can be no tree removal required or requested as part of the permit requirements. 2. The property must not be located in a Historic or NCD3 District, or have any existing code violations. 3. Does not apply to application in need of a Waiver, Warrant, Exception, Variance, or Replat. 4. A turnaround time of no more than 2 separate 7 day periods must be adhered to from the application design professional.
Fence
Flooring Replacement
Waterproofing
Window Replacements
Storefronts
Shutter Installation/Replacement
Awning/Canopies/Trellis
Roofing
Burglar Alarm
Access Control Devices (Less than 20)
Interior Wiring Lights/Receptacles
Any Hard Wired or Plug-in Electrical Equipment
Service Upgrade or Repair
Fire Alarm Devices (Less than 50)
A/C Change-outs
A/C Stand Replacement for a Re-roof
Chiller & Cooling Tower Replacements
Boiler Replacements
Miscellaneous Piping
Pool Heaters
Temporary Toilet
Sewer Cap
Sewer Repair
Plumbing Fixture Replacement
Water Service Repair/Replacement
Signed and sealed survey (no more than 1 year old) depicting location of fence and a detail of the fence up to 6 ft. in height. Up to 8 ft. in height, requires Architect/Engineer signed calculations and details. If fence is located within undedicated right of way, a complete temporary encroachment covenant application with supporting documents must be submitted for approval prior to permit application.
Floor plan and Key plan. if flooring replacement is located on a 2nd floor or above, it must provide sound proofing specifications that comply with minimum FBC requirements.
The Roofing Package which includes an Instruction Page with all required documents depending on the type of roof/waterproofing work being done.
Floor plan showing location of windows, signed and sealed design pressures, and Miami-Dade County NOA or State of Florida Product Approval.
Floor plan showing location, signed and sealed design pressures, and Miami-Dade County NOA or State of Florida Product Approval.
Floor plan showing location of proposed shutters, signed and sealed design pressures, and Miami-Dade County NOA or State of Florida Product Approval.
Signed and sealed survey (no more than 1 year old) and a plan with details and structural calculations depicting location of proposed awning/canopy. Trellis requires Architect/Engineer signed calculations, plan and details.
The Roofing Package which includes an Instruction Page with all required documents depending on the type of roof work being done and the Roofing Considerations Form. Both can be found on our website at www.miamigov.com/building under the roofing dropdown list.
Permit Application only, signed and notarized by owner and Electrical Contractor.
Signed and sealed plans.
Signed and sealed plans.
Replacement only: Application only, signed and notarized by owner and Electrical Contractor.
Signed and sealed plans.
Cut sheets and signed and sealed plans showing location of devices.
For Condos & Apartments: Application only, signed and notarized by owner and Mechanical contractor. For all other commercial property: Signed and sealed plans required.
Plan showing roof layout and Miami-Dade County NOA for stand.
Signed and sealed plans.
Signed and sealed plans.
Signed and sealed plans.
Over $7,500 requires signed and sealed plans.
Permit Application only, signed and notarized by owner and contractor.
Permit Application only, signed and notarized by owner and contractor.
Site plan showing location of repair.
Floor plan showing location of fixture.
Site plan showing location of repair/replacement.