COMMERCIAL SOLAR HOT WATER

www.thermann.com.au

Page 2: COMMERCIAL SOLAR HOT WATER - Reece Plumbing · commercial hot water that allow you to continue doing what you do best - run your business. OPTION 1: Pre-designed ‘Off The Shelf’

Don’t risk it, use a licensed plumber™. www.thermann.com.au

Small commercial is defined as any solar heating system that is slightly larger than a standard residential system, or requires multiple domestic systems.Applications could include: Large domestic homes, B&B’s, town houses, retirement villages, yoga centres.

Medium commercial is defined as any application with high volume hot water and with multiple users throughout the day.Applications could include: Caravan parks, recreation clubs, swimming pools, private and Government owned schools.

Large commercial is defined as any large volume hot water usage with high temperature requirements.Applications could include: Processing, production and manufacturing plants. High temperature applications 80°C+

COMMERCIAL SOLAR HOT WATER

Small Commercial

Medium Commercial

Large Commercial

Thermann is your number one choice for high quality, reliable, commercial solar hot water systems.

Page 3: COMMERCIAL SOLAR HOT WATER - Reece Plumbing · commercial hot water that allow you to continue doing what you do best - run your business. OPTION 1: Pre-designed ‘Off The Shelf’

Don’t risk it, use a licensed plumber™. www.thermann.com.au

We endeavour to provide you with a system that is designed to suit your business, and the unique requirements your business has... That is why we have developed two approaches to commercial hot water that allow you to continue doing what you do best - run your business.

OPTION 1: Pre-designed ‘Off The Shelf’ (OTS) solar solutions.Pre-designed solar water heating systems to suit a wide range of applications. The systems are sized to suit fixed peak and daily hot water loads, and are eligible for the Small-scale Technology Certificates (STC) incentive scheme.

OPTION 2: Custom designed solar hot water solutions.If you have a complex requirement, we provide the simple solution! Thermann solar hot water systems are among the most flexible on the market, and we provide a custom design service to engineer a hot water solution that suits your unique needs.

COMMERCIAL SOLAR HOT WATER

Providing Commercial Solutions

Page 4: COMMERCIAL SOLAR HOT WATER - Reece Plumbing · commercial hot water that allow you to continue doing what you do best - run your business. OPTION 1: Pre-designed ‘Off The Shelf’

Don’t risk it, use a licensed plumber™. www.thermann.com.au

The Thermann OTS systems are pre-designed complete solar water heating systems to suit a wide range of applications. The biggest advantage of the OTS systems is that they have been certified and tested by the Clean Energy Regulator (CER) and are eligible for the Small-scale Technology Certificate (STC) incentive scheme.

OFF THE SHELF (OTS) PACKAGED COMMERCIAL SYSTEMS

OTS SYSTEMS

Collector Output (kW) Up to 17.5kW

Tank Capacity Up to 945 Ltr

Boosting Multiple 3.6kw Electric

Maximum STC’s (Z2) 347

Pitching Frames Included No

Collector Output (kW) Up to 15.5kW

Tank Capacity Up to 2,400 Ltr

Boosting Gas Post Boosting

Maximum STC’s (Z2) 312

Pitching Frames Included No

OTS Electric Boosted

OTS Gas Boosted

Page 5: COMMERCIAL SOLAR HOT WATER - Reece Plumbing · commercial hot water that allow you to continue doing what you do best - run your business. OPTION 1: Pre-designed ‘Off The Shelf’

Don’t risk it, use a licensed plumber™. www.thermann.com.au

Reece Code: 1321092 STC Values

Solar Contribution

OTS DATA SHEET

Model Number: TEC3-315G3-MDC-30

Components:3 X 30 Tube Manifolds, 90 x Tubes and Heat pipes, 3 X 315Lt Glass Lined Mid element Tanks, Pump, Controller.

Performance:Recovery Rate: 185L/hr (50°C temp rise)24 Hour Capacity: 5,080 L (50°C temp rise)

All performance values are estimates based on ideal conditions.

Zone 1 Zone 2 Zone 3 Zone 4

100 112 100 89

Tropical Climate1 Cool Climate2

Daily Solar Heat (kWh)

Solar Contribution (%)

Daily Solar Heat (kWh)

Solar Contribution (%)

Summer 31 77 33 70

Autumn 24 54 20 40

Winter 22 43 13 24

Spring 29 66 25 47

Annual Avg. 9,652 59 8,301 44

Assumptions:1 Tropical Climate: NASA Weather Data for the Monthly Averaged Data for Brisbane has been used for this calculation to determine average daily insolation and inlet water temperature. A 30 Degree Tilt is assumed.

2 Cool Climate: NASA Weather Data for the Monthly Averaged Data for Melbourne has been used for this calculation to determine average daily insolation and inlet water temperature. A 30 Degree Tilt is assumed.

Recovery Rate: The amount of hot water that the water heater can continually produce, usually reported as flow rate in litres per hour that can be maintained for a specific temperature rise through the water heater, assuming no solar.

24 hour hot water capacity: The amount of hot water that can be provided throughout the day if there is a constant draw of hot water, assuming no solar.

GRUNDFOS ALPHA 2 CIRCULATINGSOLAR PUMP

ISOLATION VALVE

CHECK VALVE

PRESSURE LIMITING VALVE

COLD WATER EXPANSION VALVE

BALL VALVE FOR TANK ISOLATION

PRESSURE, TEMPERATURE RELIEF VALVE.

TO DRAIN TO DRAINAGE

SYSTEMPUMP UNIONS

SOLAR CHECK VALVE

ISOLATION VALVE AND DRAIN

THERMANN DELTASOL BS/4 CONTROL PANEL

TEMPERATURE SENSOR ON MANIFOLD OUTLET

THERMANN THREE 30 EVACUATED TUBE SOLAR COLLECTORS. TO BE MOUNTED AS PER THE THERMANN AUSTRALIA TECHNICAL MANUAL. FACING NORTH IS PREFERABLE.

THERMANN GLASS LINED

315L MID ELEMENT

TANK

THERMANNTH315GLEM

POTABLE HOT WATER

FLOW

POTABLE COLD WATER SUPPLY

THERMANN GLASS LINED

315L MID ELEMENT

TANK

THERMANNTH315GLEM

TS

THERMANN GLASS LINED

315L MID ELEMENT

TANK

THERMANN TH315GLEM

TS

TSEXAM

PLE

Page 6: COMMERCIAL SOLAR HOT WATER - Reece Plumbing · commercial hot water that allow you to continue doing what you do best - run your business. OPTION 1: Pre-designed ‘Off The Shelf’

Don’t risk it, use a licensed plumber™. www.thermann.com.au

QUICK REFERENCE:OTS SYSTEMS

Reece Code

Model DescriptionSTC Values

Z1 Z2 Z3 Z4Pre-packaged Standard Thermann Commercial Systems - Electric Boosted

1321092 TEC3-315G3-MDC-303 X 30 Tube Manifolds, 90 x Tubes and Heat pipes, 3 X 315Lt Glass Lined Mid element Tanks, Pump, Controller

100 112 100 89

1321093 TEC3-315G6-MDC-303 X 30 Tube Manifolds, 90 x Tubes and Heat pipes, 6 X 315Lt Glass Lined Mid element Tanks, Pump, Controller

80 87 78 65

1321094 TEC3-400G2-MDC-303 X 30 Tube Manifolds, 90 x Tubes and Heat pipes, 2 X 400Lt Glass Lined Mid element Tanks, Pump, Controller

107 116 107 97

1321095 TEC6-315G3-MDC-306 X 30 Tube Manifolds, 180 x Tubes and Heat pipes, 3 X 315Lt Glass Lined Mid element Tanks, Pump, Controller

191 209 190 172

1321096 TEC6-315G6-MDC-306 X 30 Tube Manifolds, 180 x Tubes and Heat pipes, 6 X 315Lt Glass Lined Mid element Tanks, Pump, Controller

205 228 205 182

1321097 TEC6-315G9-MDC-306 X 30 Tube Manifolds, 180 x Tubes and Heat pipes, 9 X 315Lt Glass Lined Mid element Tanks, Pump, Controller

191 210 188 164

1321098 TEC9-315G6-MDC-309 X 30 Tube Manifolds, 270 x Tubes and Heat pipes, 6 X 315Lt Glass Lined Mid element Tanks, Pump, Controller

296 329 293 261

1321099 TEC9-315G9-MDC-309 X 30 Tube Manifolds, 270 x Tubes and Heat pipes, 9 X 315Lt Glass Lined Mid element Tanks, Pump, Controller

313 347 311 227

Pre-packaged Standard Thermann Commercial Systems - Gas Boosted

1321100 TBC3-315G3-322-303 x 30 Tube Manifolds, 90 x Tubes and Heat Pipes, 3 X

315Lt Glass Lined Tanks, 2 x 32L/min gas boosters75 79 78 68

1321101 TBC4-400G3-321-304 x 30 Tube Manifolds, 120 x Tubes and Heat Pipes, 3 X

400Lt Glass Lined Tanks, 1 x 32L/min gas booster138 146 138 123

1321102 TBC4-400G3-322-304 x 30 Tube Manifolds, 120 x Tubes and Heat Pipes, 3 X

400Lt Glass Lined Tanks, 2 x 32L/min gas booster134 142 135 119

1321103 TBC5-400G4-321-305 x 30 Tube Manifolds, 150 x Tubes and Heat Pipes, 4 X

400Lt Glass Lined Tanks, 1 x 32L/min gas booster180 191 181 161

1321104 TBC5-400G4-322-305 x 30 Tube Manifolds, 150 x Tubes and Heat Pipes, 4 X

400Lt Glass Lined Tanks, 2 x 32L/min gas booster176 186 177 157

1321105 TBC6-400G4-322-306 x 30 Tube Manifolds, 180 x Tubes and Heat Pipes, 4 X

400Lt Glass Lined Tanks, 2 x 32L/min gas boosters217 230 218 195

1321106 TBC6-400G4-323-306 x 30 Tube Manifolds, 180 x Tubes and Heat Pipes, 4 X

400Lt Glass Lined Tanks, 3 x 32L/min gas boosters214 227 215 191

1321107 TBC8-400G5-323-308 x 30 Tube Manifolds, 240 x Tubes and Heat Pipes, 5 X

400Lt Glass Lined Tanks, 3 x 32L/min gas boosters295 312 297 266

1321108 TBC8-400G6-324-308 x 30 Tube Manifolds, 240 x Tubes and Heat Pipes, 6 X

400Lt Glass Lined Tanks, 4 x 32L/min gas boosters281 298 283 250

Page 7: COMMERCIAL SOLAR HOT WATER - Reece Plumbing · commercial hot water that allow you to continue doing what you do best - run your business. OPTION 1: Pre-designed ‘Off The Shelf’

Don’t risk it, use a licensed plumber™. www.thermann.com.auDon’t risk it, use a licensed plumber™. www.thermann.com.au

For clients who have a complex requirement, we provide a simple solution! We provide a custom design service to engineer a hot water solution that suits your businesses unique needs. Whether it’s 1,000 litres per day of 90°C hot water, or 50,000 litres of 50°C water we can advise a system that suits your location, requirements and budget.

We partner with you to make designing a custom hot water solution simple. We support you throughout all three phases of the design and installation process, and our technical team is available for on-site advice, training and system commissioning.

CUSTOM DESIGNED AND ENGINEERED SOLUTIONS

CUSTOM SOLUTION DESIGN PROCESS

Project form completed

System design, proposal and bill of

materials completed.

Acceptance of proposal

Installation and commissioning of system completed

Installation requirements gathered

and quotation produced

Delivery of proposal to customer

CUSTOM SOLUTION

Phase 1 Phase 2 Phase 3

Page 8: COMMERCIAL SOLAR HOT WATER - Reece Plumbing · commercial hot water that allow you to continue doing what you do best - run your business. OPTION 1: Pre-designed ‘Off The Shelf’

Don’t risk it, use a licensed plumber™. www.thermann.com.au

COMMERCIAL FORM

1. Please ensure information provided in this form accurately represents the proposed project site.

2. Completed forms can be lodged at your Reece branch, or to your local Thermann relationship manager.

3. If the required information is incomplete, we will not be able to complete the proposal and more information may be requested.

This form represents the first phase of producing a custom commercial proposal.Completing this form helps accurately determine system requirements and assists in developing a system to suit the clients needs.

Applicant Type: End-User Installer

Retailer Consultant

Applicant Name:

Contact Number:

Company:

Address:

Suburb/City:

State:

Postcode:

Email:

Reece Contact:

Thermann RM:

Project Name:

Suburb/City: State: Postcode:

Indicative Budget:

Important Information

Introduction Client Details

Project Details

Page 9: COMMERCIAL SOLAR HOT WATER - Reece Plumbing · commercial hot water that allow you to continue doing what you do best - run your business. OPTION 1: Pre-designed ‘Off The Shelf’

Don’t risk it, use a licensed plumber™. www.thermann.com.au

COMMERCIAL FORM

Length: m Width: m Average Height: m

Pitch: ° Roof Orientation: N NW W NE E

Is there limitation in tank storage: Yes No

Plant room location: Indoor Outdoor

Length: m Width: m Height: m

Is there an existing system: Yes No

How will the new system be installed: Complete replacement Retrofit existing

Storage size: L Heating Capacity: kW

Number of units: Model name/number:

Running costs: $/kWh (Electricity) $/MJ (Natural gas/LPG)

Installation Details

Collector Location Details

Plant Room Detail

Existing System Detail

Length (m)

Pitch (°)

Ave

rage

Hei

ght

(m)

Width (m

)

Page 10: COMMERCIAL SOLAR HOT WATER - Reece Plumbing · commercial hot water that allow you to continue doing what you do best - run your business. OPTION 1: Pre-designed ‘Off The Shelf’

Don’t risk it, use a licensed plumber™. www.thermann.com.au

Electricity Natural Gas Wetback/Wood-Fire Boiler

Liquid Petroleum Gas Other:

Apartment/Unit Block Hotel/Motel Nursing Home

Shower Block/Gymnasium Commercial Office Other:

Type Of Solar Thermal System

Energy Source

1. Sanitary Hot Water Service

Please provide details for one of the methods below:

Method A. Metering:

Method B. Utility Bills (Please attach)

Method C. Estimation (Please attach drawings if possible)

Or one of the below:

COMMERCIAL FORM

Daily demand: L/day

Peak demand L/hour Number of peaks: Peaks/day

Hot water load: kWh (elec) MJ (gas)

Billing period:

Type of fixture: Number of fixtures:

Type of fixture: Number of fixtures:

Type of fixture: Number of fixtures:

Number of Motels/Hotels Number of meals: per day (Food services)

Number of apartments Number of people: (Office building)

Number of students: Number of beds: (Nursing home)

Page 11: COMMERCIAL SOLAR HOT WATER - Reece Plumbing · commercial hot water that allow you to continue doing what you do best - run your business. OPTION 1: Pre-designed ‘Off The Shelf’

Don’t risk it, use a licensed plumber™. www.thermann.com.au

2. Commercial Pool Heating Service

3. Dairy Hot Water Service

Type Of Solar Thermal System - Continued

COMMERCIAL FORM

Site type: Outdoor Outdoor (enclosed) Indoor

Length: m Width: m Depth: m

Desired pool temperature: 26°C (training) 28°C (Recreational) 32°C (Therapeutic)

Is there an existing pool cover: Yes No

Summer: hrs Autumn: hrs Winter: hrs Spring: hrs

Is a new auxiliary heating required: Yes No

Auxiliary heat source LPG Boosted NG Boosted Heat Pump

Daily pool hours of operation:

If pool is indoor, please anser the following:

Indoor temperature: °C Humidity %

Daily hot water load: L/day Number of cycles per day

Temperature required: °C

Page 12: COMMERCIAL SOLAR HOT WATER - Reece Plumbing · commercial hot water that allow you to continue doing what you do best - run your business. OPTION 1: Pre-designed ‘Off The Shelf’

Don’t risk it, use a licensed plumber™. www.thermann.com.au

Type Of Solar Thermal System - Continued

Relevant Files/Documents

COMMERCIAL FORM

4. Special Applications

Application type:

Is daily hot water load or energy known? Yes No

Daily volume: L/day Daily energy: kWh/day

Flow temperature: °C Return temperature: °C

Flow Rate L/min

Is there a special schedule for usage? Yes No

Description:

Please attach any relevant information with your submission of the project form. (E.g. Design schematics of existing system, photos of site, energy/water usage bills and data).

This is a free service offered to help ensure the solar collectors are installed in accordance with manufacturers guidelines. Proposals do not assess the engineering of the complete system and the manufacturer accepts no responsibility or liability for the project. All system designs provided must be approved by a local engineer and/or installer to meet all relevant industry guidelines, regulations and codes. Installations must comply by industry best practise and be done by a qualified installer.