Community Development 18400 Murdock Circle, Port Charlotte, FL 33948 Phone: 941.743.1201 FAX: 941.764.4907 Zoning: 941.743.1964 www.CharlotteCountyFl.gov "To exceed expectations in the delivery of public services" Application Date Permit Number For Office Use Only CSR Initials 20 Components and Cladding Design Pressures: I certify to the best of my knowledge and belief that these plans and specifications have been designed to comply with the structural portion of the Building Code for wind, flood and gravity loads as amended and enforced by the permitting jurisdiction. Architect / Engineer Seal RESIDENTIAL ONE AND TWO SINGLE FAMILY DWELLING DATA SUMMARY SHEET Florida Building Code Sixth Edition (2017) Applicable Codes: Building, Mechanical, Plumbing, Accessibility, & Energy Codes - 6th Edition (2017) Florida Building Code, Residential Volume. Electrical Code - NFPA 70 & NEC 2014 Method of Design per Florida Building Code (FBC) R301: Basic Wind Speed (Vult) mph (Figure R301.2(4) Exposure Category Section (R301.2.1.4) Structural Forces (Section R301.4 / 301.5 / 3601.6) Mean roof height ft Nominal Design Wind Speed (Vasd) m.p.h. Floor Design: Dead Load p.s.f p.s.f Window and Door Wind Pressure Design Loading: Windows Doors Garage Doors p.s.f Roof Design: Live Load Dead Load p.s.f Zone 1: Zone 2: Zone 3: Zone 5: Zone 4: p.s.f p.s.f p.s.f p.s.f Protection of Openings: Living (Sq. Ft.) Garage (Sq. Ft.) Lanai (Sq. Ft..) Entry (Sq. Ft.) Storage (Sq. Ft.) Other (Sq. Ft.) TOTAL (Sq. Ft.) Area Tabulation: Signature: Date: Doors: Manufacturer's Product Approvals Windows: Overhead Doors: Mitered Glass: Shutters: Roof Coverings: Soffit: ASCE 7 MAF Guide AF & PA AISI S230 ICC 600 Florida Building Code, 6th Ed (2017) Other: B C OWNER NAME: PROJECT ADDRESS: Number & Street City, State, & Zipcode Risk Category: I II Flood Design Data D Soil Design Load-Bearing Value Roof Slope Designer's Name: Live Load p.s.f p.s.f p.s.f p.s.f Design Data: 12/2017 jg TMS/ASCE Final Floor Elevation Print Form 160 15 124 SLAB ON GRADE + 33.5/-44.8 + 33.5/-44.8 + 29.4/-33.3 20 TC=20 BC=10 19.2/-30.6 19.2/-53.2 19.2/-78.8 33.5/-44.8 33.5/-36.3 2,416 604 211 98 3,329 SEE ATTACHED SEE ATTACHED SEE ATTACHED SEE ATTACHED SEE ATTACHED SEE ATTACHED SEE ATTACHED D. R. HORTON, INC. Lot 5/811 2346 Greenland Ct Punta Gorda FL 33983 N/A 2000 PSF 5:12 STRUCTURAL SYSTEM OF NORTH FL 40 see site plan

Community Development For Office Use Only Permit Number · lowest point of garage shall be set above base flood elevation per fema flood map standard sgd recess 1-1/2". impact glass

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Community Development For Office Use Only Permit Number · lowest point of garage shall be set above base flood elevation per fema flood map standard sgd recess 1-1/2". impact glass

Community Development 18400 Murdock Circle, Port Charlotte, FL 33948

Phone: 941.743.1201 FAX: 941.764.4907 Zoning: 941.743.1964

www.CharlotteCountyFl.gov "To exceed expectations in the delivery of public services"

Application Date

Permit NumberFor Office Use Only

CSR Initials

20

Components and Cladding Design Pressures:

I certify to the best of my knowledge and belief that these plans and specifications have been designed to comply with the structural portion of the Building Code for wind, flood and gravity loads as amended and enforced by the permitting jurisdiction.

Architect / Engineer Seal

RESIDENTIAL ONE AND TWO SINGLE FAMILY DWELLING DATA SUMMARY SHEET

Florida Building Code Sixth Edition (2017)

Applicable Codes: Building, Mechanical, Plumbing, Accessibility, & Energy Codes - 6th Edition (2017) Florida

Building Code, Residential Volume. Electrical Code - NFPA 70 & NEC 2014

Method of Design per Florida Building Code (FBC) R301:

Basic Wind Speed (Vult) mph (Figure R301.2(4)

Exposure Category Section (R301.2.1.4)

Structural Forces (Section R301.4 / 301.5 / 3601.6)

Mean roof height ft

Nominal Design Wind Speed (Vasd) m.p.h.

Floor Design: Dead Loadp.s.f p.s.f

Window and Door Wind Pressure Design Loading:

Windows Doors Garage Doorsp.s.f

Roof Design: Live Load Dead Load p.s.f

Zone 1: Zone 2: Zone 3: Zone 5:Zone 4:p.s.fp.s.f p.s.f p.s.f

Protection of Openings:

Living (Sq. Ft.) Garage (Sq. Ft.) Lanai (Sq. Ft..)

Entry (Sq. Ft.) Storage (Sq. Ft.) Other (Sq. Ft.)

TOTAL (Sq. Ft.)Area Tabulation:

Signature: Date:

Doors:

Manufacturer's Product Approvals

Windows:Overhead Doors:

Mitered Glass:

Shutters:

Roof Coverings:

Soffit:

ASCE 7 MAF GuideAF & PAAISI S230

ICC 600

Florida Building Code, 6th Ed (2017)

Other:

B C

OWNER NAME: PROJECT ADDRESS:

Number & Street City, State, & Zipcode

Risk Category: I II

Flood Design Data

D Soil Design Load-Bearing Value

Roof Slope

Designer's Name:

Live Load

p.s.f

p.s.fp.s.f

p.s.f

Design Data:

12/2017 jg

TMS/ASCE

Final Floor Elevation

Print Form

160

15

124

SLAB ON GRADE

+ 33.5/-44.8 + 33.5/-44.8 + 29.4/-33.3

20 TC=20 BC=10

19.2/-30.6 19.2/-53.2 19.2/-78.8 33.5/-44.833.5/-36.3

2,416 604 211

98

3,329

SEE ATTACHED SEE ATTACHEDSEE ATTACHED

SEE ATTACHED

SEE ATTACHED

SEE ATTACHED

SEE ATTACHED

D. R. HORTON, INC. Lot 5/811 2346 Greenland Ct Punta Gorda FL 33983

N/A

2000 PSF

5:12

STRUCTURAL SYSTEM OF NORTH FL

40

see site plan

derek
Seal Transparent
derek
Statement 3
Page 2: Community Development For Office Use Only Permit Number · lowest point of garage shall be set above base flood elevation per fema flood map standard sgd recess 1-1/2". impact glass
derek
Shop Drawing Stamp
derek
Accepted
Page 3: Community Development For Office Use Only Permit Number · lowest point of garage shall be set above base flood elevation per fema flood map standard sgd recess 1-1/2". impact glass

5"

12"

5"

12"

5"

12"5"

12"

5"

12"

5"

12"

5"

12"

5"

12"

FINISH FLOORELEV. @ 0"

FINISH FLOORELEV. @ 0"

TOP OF BEAM (MAIN)ELEV. @ 9'-4"

TOP OF BEAM (MAIN)ELEV. @ 9'-4"

8'-0

"

2-25 SH2-26 SH 3080 ENTRY16080 OHGD8080 OHGD

SHINGLE ROOF

TOP OF BEAM (ENTRY)ELEV. @ 12'-8"

TOP OF BEAM (ENTRY)ELEV. @ 12'-8"

1'-4"1'-4"

1'-4"1'-4" 1'-4"

1'-4"

4" RAISED DECO BANDING

4" RAISED DECO BANDING

4" RAISED DECO BANDING

DECO TECTURE FINISH

11

'-0

"

FINISH FLOORELEV. @ 0"

FINISH FLOORELEV. @ 0"

TOP OF BEAM (MAIN)ELEV. @ 9'-4"

TOP OF BEAM (MAIN)ELEV. @ 9'-4"

SHINGLE ROOF

2-35 SH 2-35 SH 1/2 33 SH 25 SH12080 SL GL DR

DECO TEXTURE FINISH OVER CONC. BLOCK

1'-4"

8'-0

"

1'-4"

FINISH FLOORELEV. @ 0"

FINISH FLOORELEV. @ 0"

TOP OF BEAM (MAIN)ELEV. @ 9'-4"

TOP OF BEAM (MAIN)ELEV. @ 9'-4"

48" x 16" 25 SH

SHINGLE ROOF

DECO TEXTURE FINISH OVER CONC. BLOCK

TOP OF BEAM (ENTRY)ELEV. @ 12'-8"

3'-4"

1'-4"

8'-0

"

1'-4"

FINISH FLOORELEV. @ 0"

FINISH FLOORELEV. @ 0"

TOP OF BEAM (MAIN)ELEV. @ 9'-4"

TOP OF BEAM (MAIN)ELEV. @ 9'-4"

25 SH 1/2 33 SH

SHINGLE ROOF

DECO TEXTURE FINISH OVER CONC. BLOCK

TOP OF BEAM (ENTRY)ELEV. @ 12'-8"

TOP OF BEAM (ENTRY)ELEV. @ 12'-8"

1'-4" 1'-4"1'-4"

3'-4"

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

1/4" = 1'-0"

Y:\0-N

ew D

ata\

1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\S

UBD

IVIS

IONS\D

EEP

CREEK S

OUTH\1

1571 L

OT 1

4 B

LK 8

16 2

414 A

L\REVIT

\11571 2

414 A

L.rv

t

A-1 AL

ELEVATION

24

14

MO

DEL

JWC

JBL

03/23/20

LOT:

14

BLO

CK:

816

SUBD

IVIS

ION:

DEEP C

REEK S

OUTH

AD

DRS:

23

05 B

ONN C

OURT

D.R

.H.

#:

57

97

00

029

GC

D J

OB #

11

571

1/4" = 1'-0"

FRONT ELEVATION "AL"

1/4" = 1'-0"

REAR ELEVATION "AL"

1/4" = 1'-0"

RIGHT ELEVATION "AL"

1/4" = 1'-0"

LEFT ELEVATION "AL"

Page 4: Community Development For Office Use Only Permit Number · lowest point of garage shall be set above base flood elevation per fema flood map standard sgd recess 1-1/2". impact glass

WH

HB

HB

OR DOORS

21" MIN. TOFIXTURES, WALLS 1'-9"

8'-0

"36" MAX.

OR DOORS

21" MIN. TO FIXTURES, WALLS

MIN.

1'-0"

19

" M

IN.

19

" M

IN.

15" MIN.TO FINISH

FRONT ELEVATION SIDE ELEVATION

WATER CLOSET CLEARANCE DETAIL

8'-0

"

FRONT ELEVATION SIDE ELEVATION

VANITY SINK CLEARANCE DETAIL

4"

2'-5

1/2

"

8'-0

"

VARIES

4"

2'-5

1/2

"VARIE

S

VARIES

8'-0

"

MIRROR

FAUCET

KICK PLATE

FAUCET

MIRROR

14'-4"16'-0"1'-4"10'-0"18'-0"

59'-8"

14'-4"16'-4"29'-0"

55

'-4

"8

"3

'-4

"

16'-8 1/2"1'-3 1/2"11'-4"

59

'-4

"

2'-3

"6

'-3

"2

'-5

1/2

"2

3'-8

1/2

"2

1'-4

"

REF. SPACE

13

'-8

"1

1'-0

"1

2'-0

"

9 1/2"3'-5"12'-1 1/2"

13'-8"1'-4"1'-8"16'-0"1'-8"8'-4"1'-4"

SET A/C PAD ABOVE FLOOD W/ 1'-0" FREEBOARD PER FBCR R322.2.1

LOWEST POINT OF GARAGE SHALL BE SET ABOVE BASE FLOOD ELEVATION PER FEMA FLOOD MAP

STANDARD SGD RECESS 1-1/2". IMPACT GLASS SGD RECESS RECESS 2-1/2".

PAVERS BY OTHERS

16'-0" X 8'-0" O.H. GARAGE DOOR8'-0" X 8'-0" O.H. GARAGE DOOR

TIL

E S

HO

WER

RECES

S 3

-1/2

"

5'-0

" TU

B/ S

HW

R

RUN CONDUIT FOR ELECTRIC AT ISLAND

PROVIDE 1/4" WATER LINE @ REF. SPACE FOR ICE MAKER

5'-0

" TU

B/ S

HW

R

6" X 12" RECESS

6" X 12" RECESS

PAVERS BY OTHERS

1'-11"12'-2"1'-11"11'-4"

ELEV. @ 0'-(-4")

ELEV @ 0'-(-4")

ELEV. @ 0'-(-4")

WASHER

9'-9

"3

'-1

0"

3'-1

0"

19

'-3

"

23

'-4

"3

'-0

"1

0'-8

"2

2'-4

"

2'-4"11'-2 1/2"46'-1 1/2"

2'-1"2'-7"

3'-5 1/2"5'-5"17'-9"4'-11"16'-2 1/2"2'-5"4'-10"

8F8-1B SET AT GARAGE DOOR HEAD HEIGHT, ADD COURSING AS, REQUIRED TO 8X8 BOND BEAM W/ 1#5, TOP @ 9'-4" GROUT SOLID

SAWCUT SLAB PER DETAIL 5/S-3

SET W/H ABOVE FLOOD W/ 1'-0" FREEBOARD PER FBCR R322.2.1

59

'-4

"

OPT.LT.

A/H

PROVIDE TERMITE TREATMENT WITH "BORA CARE"

RANG

E

DBL

SIN

K

DW

59'-8"

3'-4

"8

"5

'-4

"

6'-8

"

11

'-0

"

12'-0"

BRASS FLOOR OUTLET W/ SWITCH

4" SLAB W/ 2,500 PSI CONC. W/ 6X6 #10/10 W.W.M. REINFORCING OVER 6 MILL VISQUEEN BARRIER ON MECHANICALLY COMPACTED FILL @ 95%.

THE FINISH FLOOR SLAB SHALL BE SET ABOVE BASE FLOOD ELEVATION PER FEMA FLOOD MAP PLUS 1'-0" FREEBOARD PER FBCR R322.2.1. SEE SITE PLAN BY OTHERS

ELEV. @ 0'-0"

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

Y:\0-N

ew D

ata\

1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\S

UBD

IVIS

IONS\D

EEP

CREEK S

OUTH\1

1571 L

OT 1

4 B

LK 8

16 2

414 A

L\REVIT

\11571 2

414 A

L.rv

t

A-2 AL

SLAB & PLUMBING PLAN

24

14

MO

DEL

JWC

JBL

03/23/20

LOT:

14

BLO

CK:

816

SUBD

IVIS

ION:

DEEP C

REEK S

OUTH

AD

DRS:

23

05 B

ONN C

OURT

D.R

.H.

#:

57

97

00

029

GC

D J

OB #

11

571

1/4" = 1'-0"

SLAB & PLUMBING "AL"

Page 5: Community Development For Office Use Only Permit Number · lowest point of garage shall be set above base flood elevation per fema flood map standard sgd recess 1-1/2". impact glass

WH

HB

HB

PLAN NOTES

1) VERIFY ALL ROUGH OPENING DIMENSIONS FOR ALL WINDOWS AND DOORS

2) PROVIDE SAFETY GLAZING WITHIN 24" FROM EXITPER FLORIDA BUILDING CODE R 308.4.2.

3) PROVIDE SAFETY GLAZING AT BATH/ SHOWER PER FLORIDA BUILDING CODE R 308.4.5.

4) NON BEARING INTERIOR FRAME WALLS SHALL BE FRAMED W/ WOOD OR METAL STUDS. SPACING SHALLNOT EXCEED 24" O.C. (NON BEARING WALLS ONLY)

5) PROVIDE DEAD WOOD IN ATTIC FOR OVERHEADGARAGE DOOR HARDWARE

6) KITCHEN KNEE WALL TO BE FRAMED W/ TOP @34 1/2" A.F.F.

7) INSTALL SMOOTH WALLS IN KITCHEN AND ALLBATHROOM AREAS

8) WHERE DRYWALL CEILING IS APPLIED TO TRUSSES@ 24" O.C. USE 5/8" DRYWALL OR 1/2" SAGRESISTANT PER SEC. 702.3.5

9) THE GARAGE SHALL BE SEPARATED FROM THERESIDENCE & ATTIC BY NOT LESS THEN 1/2" GYPSUMBOARD APPLIED TO THE GARAGE SIDE. GARAGESBENEATH HABITABLE ROOMS SHALL BE SEPARATEDWITH NOT LESS THAN 5/8" TYPE "X" GYPSUM BOARDOR EQUIVALENT. WHERE THE SEPARATIION IS AFLOOR - CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARTION SHALL ALSO BE PROTECTED BY NOT LESS THAN 1/2" GYPSOM BOARDOR EQUIVALENT

10) INSTALL 1 3/8" THICK SOLID WOOD DOOR BETWEENLIVING AND GARAGE PER FLORIDA BUILDING CODER302.1.5.

11) ALL WINDOWS INSTALLED 72" ABOVE GRADE MUSTCOMPLY WITH R612.2 MIN 24" SILL HEIGHT ORPROVIDED WITH AN APPROVED WINDOW FALL PRVENTION DEVICE

12) ALL CLOSET SHELVES TO BE 12". ALL PANTRY &LINEN TO BE (4)-16" SHELVES 18" 0.F.F. W/ 15"INCREMENT.

13) ALL MECHANICAL AND ELECTRICAL EQUIPMENT TO BEINSTALLED AT OR ABOVE FLOOD PLUS 1'-0" FREEBOARD.

DOOR HEADERS6'-8" BI-FOLD

6'-8" SWING

8'-0" SWING

HEADER HEIGHT 82" A.F.F.

82 1/2" A.F.F.

98 1/2" A.F.F.

HEADER HEIGHT

HEADER HEIGHT

CABINET BACKINGKITCHEN

MASTER BATH

GUEST BATH

LAUNDRY ROOM

UPPER TOP @ 84" BASE TOP @ 35"

UPPER

UPPER

UPPER TOP @ 84"

BASE TOP @ 35"

BASE TOP @ 31"

BASE

14'-4"16'-0"11'-4"18'-0"

59'-8"

14'-4"16'-4"29'-0"

23

'-4

1/2

"5

'-4

1/2

"2

6'-7

"4

'-0

"

12

'-6

"3

'-1

1"

11

'-0

"6

'-9

"2

1'-2

"

1'-8"9'-8"6'-8"11'-4"

4'-0"4'-6"9'-0"

13

'-9

1/2

"2

'-4

"6

'-2

"7

'-8

"6

'-4

1/2

"1

'-8

"3

'-6

"1

7'-1

0"

3'-7"4'-6 1/2"1'-6 1/2"3'-11"17'-8 1/2"28'-4 1/2"

LANAI

NOOK

BEDROOM #2

BEDROOM #3

KITCHENLAUNDRY

3 CAR GARAGE

DINING ROOM

ENTRY

FOYER

BEDROOM #4

MASTER SUITE

MASTER BATH

W.I.C.

59

'-4

"

GREAT ROOM

3'-0"4'-0"5'-5"1'-0"28'-9"4'-0"6'-2 1/2"

1'-0

"

11'-7"13'-8"1'-4"1'-8"16'-0"1'-8"4"8'-0"1'-4"

11

'-1

1"

2'-3

1/2

"6

'-4

"2

'-4

1/2

"4

'-7

"2

'-8

"2

1'-4

"

1'-11"12'-2"1'-11"

11'-7"

13

'-0

"1

0'-8

"3

5'-8

"

12" VIN

YL

SH

ELF

12" VINYL SHELF

12" VIN

YL

SH

ELF

DBL

SIN

K

REF. SPACE

LINEN

5'-0

" TU

B/ S

HW

RTIL

E S

HO

WER

RECES

S 3

-1/2

"1

2" VIN

YL

SH

ELF

12" VIN

YL

SH

ELF

12" VINYL SHELF

3'-0"4'-1"8'-3"

LINEN

6" KNEE WALL 34 1/2" TALL

LINEN

5'-4

1/2

"3

'-4

1/2

"

OVERH

EAD C

ABIN

ETS

EGRESSEGRESS

EG

RESS

EGRESS

ADC

D

DC

A

B

E

F 1

23

4

5

SEE NOTE 9

SEE NOTE 10

2

2

2

2

2

2

6

2

5

2

2

222

2

2

2

2

6

OVERHEAD CABS

12" VINYL SHELF

MIR

.

MIR

.

MIR.

21'-3 1/2"3'-7"3'-3 1/2"4'-4"9 1/2"7'-8 1/2"

5'-0

" TU

B/ S

HW

R

8"

3'-1

0"

5'-6

"

10

'-0

"

1'-2

"2

'-8

"8

"

3'-9

"5

'-4

1/2

"3

'-4

1/2

"

RANG

E DW

DRYER WASHER

1'-4"11'-11"6'-0 1/2"

MIN. R-13 OR BETTER INSULATION

BATH #2

BATH #3

ESCAPE

3'-4

"6

'-0

"

6'-8

"1

2'-2

"5

'-1

1/2

"8

'-0

1/2

"3

'-6

"7

'-1

0"

9'-4" FLAT CEILING

12'-8" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

12'-0" FLAT CEILING

12'-0" FLAT CEILING

SAFTEY G

LAZED

PANTRY

4'-3"2'-1 1/2"

OPT.12" VINYL SHELF

59

'-4

"

OPT.LT. A/H

4

15

'-3

"8

'-0

"6

'-1

0 1

/2"

12

'-0

1/2

"

SAFTEY G

LAZED

SAFTEY GLAZED

59'-8"

FACE OF OUTSIDE WALL TO FACE OF STUD WALL FACE OF STUD TO FACE OF STUD

1/2"

3 1/2"

1/2"

FACE OF EXTERIOR WALL

1/2"

3 1/2"

1/2"TYPICAL DIMENSION STRING

INTERIOR DOOR SCHEDULE

MARK

1

2

3

DOOR WIDTH NOTES

P.K. = POCKET DOOR

B.F. = BI-FOLD DOOR

B.P. = BI-PASS DOOR

L.V. = LOUVERED DOOR

4

5

6

7

8

3'-0"

2'-8"

2'-6"

2'-4"

2'-0"

1'-8"

1'-6"

2'-10"

TOILET PAPER ROLL

2'-6"

1'-8"

TOWEL BAR

4'-0"

3'-2"

MIN.

4"

MIN.

4"

BATHROOM NOTES

ALL TUB DECKS @ 21" A.F.F

ALL BLOCKING TO BE PT IN SHOWERS

TOWEL BAR

TP TOILET PAPER

TB

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

Y:\0-N

ew D

ata\

1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\S

UBD

IVIS

IONS\D

EEP

CREEK S

OUTH\1

1571 L

OT 1

4 B

LK 8

16 2

414 A

L\REVIT

\11571 2

414 A

L.rv

t

A-3 AL

FLOOR

24

14

MO

DEL

JWC

JBL

03/23/20

LOT:

14

BLO

CK:

816

SUBD

IVIS

ION:

DEEP C

REEK S

OUTH

AD

DRS:

23

05 B

ONN C

OURT

D.R

.H.

#:

57

97

00

029

GC

D J

OB #

11

571

1/4" = 1'-0"

FLOOR PLAN "AL"

SQUARE FOOTAGE

LIVING AREA 2416 SF

LANAI AREA 211 SF

GARAGE AREA 604 SF

ENTRY AREA 98 SF

TOTAL AREA 3329 SF

WINDOW SCHEDULE MARK DESCRIPTION MANUFACTURER WIDTH HEIGHT COMMENTS QTY

A 2-35 SH 9'-0" 5'-3" 2

B 48" X 16" FIXED GLASS 4'-2" 3'-4" 1

C 1/2 33 SH 2'-2" 3'-2" 2

D 25 SH 3'-2" 5'-3" 3

E 2-25 SH 6'-4" 5'-3" 1

F 2-26 SH 6'-4" 6'-4" 1

DOOR SCHEDULETYPEMARK DESCRIPTION MANUFACTURER

COMMENTS Width Height QTY

1 3080 ENTRY DISTINCTION 3'-0" 8'-0" 1

2 16080 OHGD GARAGE DOOR 16'-0" 8'-0" 1

3 8080 OHGD GARAGE DOOR 8'-0" 8'-0" 1

4 (3)-4080 SL. GL. DR. 12'-0" 8'-0" 1

5 2880 ENTRY DISTINCTION 2'-8" 8'-0" 1

OPT IMPACT GLASS MAY BE INSTALLED IN LIEU OF SHUTTERS VERIFY W/ CONTRACT

Page 6: Community Development For Office Use Only Permit Number · lowest point of garage shall be set above base flood elevation per fema flood map standard sgd recess 1-1/2". impact glass

WH

HB

HB

LANAI

NOOK

BEDROOM #2

BEDROOM #3

KITCHENLAUNDRY

3 CAR GARAGE

DINING ROOM

ENTRY

FOYER

BEDROOM #4

MASTER SUITE

MASTER BATH

W.I.C.

GREAT ROOM

REF. SPACE

3'-3"

RIDGE

RID

GE

RID

GE

RID

GE

HIPHIP

HIPHIP

HIPHIP

HIP

VALLEY

VALLEY

HIP

HIP HIP

HIP

VALLEY

VALLEY

VALLEY

BATH #2

BATH #3

1'-0

"

1'-0

"

9'-4" FLAT CEILING

12'-8" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

12'-0" FLAT CEILING12'-0" FLAT CEILING

RID

GE

1'-0

"1'-0

"

MODEL 2414 A: ATTIC VENTILATION FBCR R806

SOFFIT ONLY (1/150) WITH ROOF VENTS (1/300)

AREAS (SQ. FT.) ATTIC VENTILATION REQUIRED ATTIC VENTILATION REQUIRED

MARK SOFFIT

3328.2 SQ. FT.

ATTIC AREA/150

6.66% -.-- SQ. FT. -.-%

COORDINATE VENTING REQUIREMENTS WITH ENERGY CALCULATIONS

(R.V.)

ROOF VENTS ARE NOT REQUIRED

32" BASE

22

-3/8

" BASE

LOMANCO 770-D 0.97 SQ. FT. FREE AIR

(NO ROOF VENTS)

22.19 SQ.FT.

"SOFFIT ONLY" QUALIFIES

SOFFIT MODEL

ACM QUAD 4, FULL VENT, NARROW PATTERN, 8.15% FREE AIR FLOW

ATTIC

333.3 SQ. FT.

MIN AIR FLOW OF SOFFIT

ROOF VENT MODEL

1st STORY

REQ'D AIR FLOW

OF SOFFIT

QUAD 4 SOFFIT

HAS

8.15%

ATTIC AREA/300QUANTITY OF

ROOF VENTS

-

BEARING HEIGHT

= BEARING @ 9'-4"

= INTERIOR BEARING @ 9'-4"

= BEARING @ 12'-8"

= INTERIOR BEARING @ 12'-8"

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

Y:\0-N

ew D

ata\

1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\S

UBD

IVIS

IONS\D

EEP

CREEK S

OUTH\1

1571 L

OT 1

4 B

LK 8

16 2

414 A

L\REVIT

\11571 2

414 A

L.rv

t

A-4 AL

ROOF

24

14

MO

DEL

JWC

JBL

03/23/20

LOT:

14

BLO

CK:

816

SUBD

IVIS

ION:

DEEP C

REEK S

OUTH

AD

DRS:

23

05 B

ONN C

OURT

D.R

.H.

#:

57

97

00

029

GC

D J

OB #

11

571

1/4" = 1'-0"

ROOF PLAN "AL"

Page 7: Community Development For Office Use Only Permit Number · lowest point of garage shall be set above base flood elevation per fema flood map standard sgd recess 1-1/2". impact glass

WH

HB

HB

33

3

33

TV

TV

TV

TV

TV

T

T

P

P

P

33

200 AMP ELECTRICAL RISER DIAGRAM

200 AMP

PANELM

(2) 4/0 AL & (1) 1/0 AL

OR CU EQUIVALENT

#6 CU MIN. TO (2) GROUND RODS,

AT LEAST 6FT APART.

POWER CO.

J

ELECTRICAL NOTES:

ALL OUTLETS IN WET AREAS AND ALL

ALL ELECTRIC, ELECTRICAL EQUIPMENT AND APPLIANCES TO BE SET AT

OR ABOVE BASE FLOOD ELEVATION PLUS 1'-0" FREEBOARD.

ARC-FAULT CIRCUIT-INTERRUPTERS AND TAMPER

RESISTANT RECEPTACLES SHALL BE INSTALLED

INSTALL PHONE AND T.V PER CONTRACT.

IN DWELLING UNITS PER N.E.C 210.12 AND 406.11

EXTERIOR OUTLETS TO BE GFI'S.

NOTE: NOT ALL SYMBOLS ARE USED FOR THIS

PROJECT.

SURFACE MOUNTED CEILING LIGHT

TELEVISION RECEPTION OUTLET

AC/DC SMOKE DETECTORTO BE INTERCONNECTED

WALL MTD. BRACKET LIGHT

DIMMER SWITCH

3 WAY SWITCH

SINGLE POLE SWITCH

TELEPHONE OUTLET

MOTION SENSOR SWITCH

A/C DISCONNECT

DUPLEX FLOOD LIGHT

TRACK MTD. LIGHTS

EXHAUST FAN

PUSH BUTTON (PB) / DOOR BELL (DB)

FLUSH MOUNTED LIGHT

1/2 SWITCHED DUPLEX OUTLET

DUPLEX RECEPTACLE OUTLET

4-PLEX RECEPTACLE OUTLET

220 V RECEPTACLE OUTLET

SINGLE RECEPTACLE OUTLET

DUPLEX RECEPTACLE AT ELEV. A.F.F.

ELECTRICAL PANEL

ELECTRICAL METER

120 V JUNCTION BOX

DUPLEX RECEPTACLE - ABOVE COUNTER

3

D

SD

TV

ELECTRICAL LEGEND

2' UNDER COUNTER LIGHT

4' FLUORESCENT LIGHT

INTERCOMIC

KP

KEYPAD

ANY RESIDENT HAVING A FOSSIL-BURNING

HEATER OR APPLIANCE, A FIREPLACE, OR

AN ATTACHED GARAGE SHALL HAVE AN

OPERATIONAL CARBON MONOXIDE ALARM

INSTALLED WITHIN 10 FEET OF EACH

ROOM USED FOR SLEEPING PERPOSES.PER RULE 9B-3.04.72SD (SMOKE DETECTOR)SCD (CARBON MONOXIDE/ SMOKEDETECTOR)

AFF

MS

INSTALL ALL ELECTRICAL PER NEC 2014

SCD

T

ELECTRICAL PLAN 2414

200 AMP SERVICE

TAGABCDEFGHIJKLMNOPQ

QUANTITY PRODUCT(17)(3)(3)(15)(4)(X)(X)(2)(X)(1)

(X)(X)(X)(X)(X)(X)(X)

(FLUSH MOUNTED LIGHT)(VAPORS)(PENDANT LIGHT(10" MUSHROOMS)(24" 3 LT)(36" 4 LT)(NOT USED)(COACH LIGHTS)(COACH LIGHTS)(J BOX)

(4' FLUORESCENT)(2' FLUORESCENT)(5LT CHANDELIER)(3 LT)(PENDANT/ NOOK)(X)(X)

A/H

11

'-0

"

12'-0"

BRASS FLOOR OUTLET W/ SWITCH

STUB OUT FOR GARAGE DOOR OPENER

STUB OUT FOR GARAGE DOOR OPENER

SD

SCD

SD

SCD

SD

SDSCD

DB

ATTIC LIGHT

GFI

D

D

D

D

D

D

D

EXH. FAN/LIGHT

EXH. FAN/LIGHT

EXH. FAN/LIGHT

EXH. FAN/LIGHT

KEYLESS

A/C DISCONNECT

A/C DISCONNECT

PRE-WIRE FOR FAN (TYP.)

PRE-WIRE FOR FAN (TYP.)

PRE-WIRE FOR FAN (TYP.)

PRE-WIRE FOR FAN (TYP.)

PRE-WIRE FOR FAN (TYP.)

PRE-WIRE FOR FAN (TYP.)

ELECTRIC METER

200 AMP PANEL

H

GFIWP

GFI@ 42" A.F.F.

GFI@ 42" A.F.F.

GFIWP

GFIWP

GFIWP

GFI

GFI

GFI

GFI

GFI

GFIGFI

GFI

GFI

GFI

GFI

VP

GFI

GFI

AOPT.

AOPT.

AOPT.A

OPT.

A

AA

AA

A A

H

A

D

D

A

A

D

D

D

A

A

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

Y:\0-N

ew D

ata\

1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\S

UBD

IVIS

IONS\D

EEP

CREEK S

OUTH\1

1571 L

OT 1

4 B

LK 8

16 2

414 A

L\REVIT

\11571 2

414 A

L.rv

t

A-5 AL

ELECTRICAL

24

14

MO

DEL

JWC

JBL

03/23/20

LOT:

14

BLO

CK:

816

SUBD

IVIS

ION:

DEEP C

REEK S

OUTH

AD

DRS:

23

05 B

ONN C

OURT

D.R

.H.

#:

57

97

00

029

GC

D J

OB #

11

571

1/4" = 1'-0"

ELECTRICAL PLAN "AL"

Page 8: Community Development For Office Use Only Permit Number · lowest point of garage shall be set above base flood elevation per fema flood map standard sgd recess 1-1/2". impact glass

RESIDENTIAL SPECIFICATIONS

1. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS ATTHE JOB SITE PRIOR TO COMMENCING WORK. THE CONTRACTOR SHALLREPORT ALL DISCREPENCIES BETWEEN THE DRAWINGS AND EXISTINGCONDITIONS TO THE DESIGNER PRIOR TO COMMENCING WORK.

2. THE CONTRACTOR SHALL SUPPLY, LOCATE AND BUILD INTO THE WORKALL INSERTS, ANCHORS, ANGLES, PLATES, OPENINGS, SLEEVES,HANGERS, SLAB DEPRESSIONS AND PITCHES AS MAY BE REQUIRED TOATTACH AND ACCOMMODATE OTHER WORK.

3. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDEDTO BE TYPICAL AND SHALL BE CONSTRUCTED TO APPLY TO ANY SIMILARSITUATION ELSEWHERE IN THE WORK EXCEPT WHERE A DIFFERENTDETAIL IS SHOWN.

4. SUBSURFACE SOIL CONDITION INFORMATION IS NOT AVAILABLEFOUNDATIONS ARE DESIGNED FOR A SOIL BEARING CAPACITY OF 2,000PSF. THE CONTRACTOR SHALL REPORT ANY DIFFERING CONDITIONS TOTHE DESIGNER PRIOR TO COMMENCING WORK.

5. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUCTION WITH JOBSPECIFICATION AND HOUSE PLANS, MECHANICAL, ELECTRICAL, PLUMBING, AND SITE DRAWINGS, CONSULT THESE DRAWINGS FORSLEEVES, DEPRESSIONS AND OTHER DETAILS NOT SHOWN ONSTRUCTURAL DRAWINGS.

6. ALL SPECIFIED FASTENERS MAY ONLY BE SUBSTITUTED IF APPROVED BY THE ENGINEER IN WRITING, THE INSTALLATION OF THE FASTENERSSHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS.SIMPSON FASTENERS SPECIFIED MAY BE SUBSTITUTED WITH THE SAME QUANTITYAND EQUIVALENT STRENGTH PRODUCT.ALL BOLTS, NUTS, WASHERS, STRAPS AND FASTENERS INCLUDINGNAILS, SHALL BE HOT MOPED DIPPED GALVANIZED OR STAINLESS STEEL CONTINUOUS ANCHORAGE SHALL BE PROVIDED BETWEEN ALL TRUSSES,WALL SECTIONS, BEAMS, POSTS AND FOOTINGS WITH USE OF STRAPSAND CONNECTORS AS SPECIFIED HEREIN.

7. TREATED WOOD REQUIREMENTS:-ALL TREATED WOOD EXPOSED TO WEATHER SHALL BE PROTECTED, PRESSURE TREATED,OR NATURALLY RESISTANT TO DECAY.ALL WOOD TOUCHING MASONRY OR CONCRETE SHALL BE ISOLATED, ORPRESSURE TREATED.

8. THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTERTHE BUILDING IS COMPLETE. IT IS THE CONTRACTOR'S SOLE RESPONSIBILTYTO DETERMINE ERECTION PROCEDURES AND SEQUENCES TO ENSURE SAFETY OFTHE BUILDING AND ITS COMPONENTS DURING ERECTION. THIS INCLUDES THE NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUYS, OR TIE DOWNS.

9. CEILING DRYWALL INSTALLED WITHIN THE HOUSE TO TRUSSES SPACED 24" O.C.SHALL BE 5/8" DRYWALL OR 1/2" SAG RESISTANT PER SEC. 702.3.5

10. LANAI CEILINGS & COVERED ENTRY CEILINGS1X4 STRIPPING @ 16" O.C. FASTENED WITH 2-8d NAILS TO EACH TRUSS. 5/8"EXTERIOR GYP. BOARD CEILING FASTENED WITH 8d NAILS OR 1-5/8" DRYWALLSCREWS @ 6" O.C. EDGE AND FIELD.

GENERAL NOTES

1

ROOF SHEATHINGSHALL BE APA RATED SHEATHING, EXPOSURE 1, SPAN RATING 24/16 OR BETTER.INSTALL PANELS WITH LONG DIMENSION PLACED PERPENDICULAR TO TRUSSES.A 1/8" SPACE BETWEEN ADJACENT SHEETS SHALL BE MAINTAINED . INSTALL "H" CLIPS AT UNSUPPORTED PANEL EDGES. THE ROOF SHEATHING SHALL BE NAILED WITH8d RING SHANK NAILS @ 4" O.C. EDGE AND 6" O.C. FIELD. ENSURE THAT ALL NAILS PENETRATE THE TOP CHORD OF THE TRUSSES WITHOUT SPLITTING. RING SHANK NAILSPER R803.2.3.1 - 0.113" NOMINAL SHANK DIAMETER, RING DIAMETER OF 0.012"OVER SHANK DIAMETER, 16 TO 20 RINGS PER INCH, 0.280" DIAMETER FULLROUND HEAD, 2" NAIL LENGTH.

FLASHINGFLASHING SHALL BE ALUMINUM, ALUMINUM ZINC COATED STEEL 0.0179" THICK,26 GAUGE AZ50 ALUM ZINC, OR GALVANIZED STEEL 0.0179" THICK, 26 GAUGEZINC COATED G90. FLASHING SHALL BE INSTALLED IN ACCORDANCE WITH THE ZIPSYSTEM ROOF SHEATHING MANUFACTURES PUBLISHED REQUIREMENTS. ALL FLASHING AND INSTALLATION SHALL CONFORM TO SECTION R905.2.8 (1 TO 5).

DRIP EDGEDRIP EDGE SHALL BE PROVIDED AT ALL EAVES AND GABLES OF SHINGLES ROOFS,LAPPED A MINIMUM OF 3" @ JOINTS. THE OUTSIDE EDGE SHALL EXTEND A MINIMUMOF 1/2" BELOW SHEATHING AND THE INSIDE EDGE SHALL EXTEND BACK A MINMUMOF 2". DRIP EDGE SHALL BE FASTENED AT NO MORE THAN 4" CENTERS. THERE SHALLBE A MINIMUM OF 4" WIDTH OF ROOF CEMENT INSTALLED OVER THE DRIP EDGE FLANGE.

GENERAL ROOF ASSEMBLY

2

INSTALL PEEL AND STICK UNDERLAYMENT APPROVED FOR SINGLE LAYER APPLICATION UNDER TILE ROOF.THE INSTALLATION OF CLAY AND CONCRETE TILE SHALL COMPLYWITH THE PROVISIONS OF R905.3 F.B.C.MARKING: EACH ROOF TILE SHALL HAVE A PERMANENTMANUFACTURER'S IDENTIFICATION MARK.APPLICATION SPECIFICATIONS: THE TILE MANUFACTURER'S WRITTENAPPLICATION SPECIFICATIONS SHALL BE AVAILABLE AND SHALLINCLUDED BUT NOT BE LIMITED TO THE FOLLLOWING:1. TILE PLACEMENT AND SPACING,2. ATTACHMENT SYSTEM NECESSARY TO COMPLYWITH CURRENT WIND CODE, A. AMOUNT AND PLACEMENT OF MORTART B. AMOUNT AND PLACEMENT OF ADHESIVE C. TYPE, NUMBER, SIZE AND LENGTH OF FASTENERS AND CLIPS.3. UNDERLAYMENT4. SLOPE REQUIREMENT.

CLAY AND CONCRETE ROOF TILE SPECS

4

SHINGLES15# FELT SHALL BE INSTALLED UNDER ASPHALT SHINGLES. ALL ASPHALT SHINGLES SHALL HAVE SELD-SEALING STRIPS OR BE INTERLOCKING AND COMPLY WITH ASTM D 225 OR D 3462, ANDSHALL BE SECURED TO THE ROOF WITH NO LESS THAN 6 FASTENERS PER SHINGLE STRIP, OR A MINIMUM OF 2 FASTENERS PER SHNGLE TAB, AND SHALL IN NO CASSE BE FASTENED WITH LESS FASTENERS THAN THAT REQUIRED BY THE MANUFACTURE.INSTALLATION SHALL COMPLY WITH MANUFACTURES REQUIREMENTS FOR INSTALLATION IN THE GIVEN FLORIDA WIND ZONE, AS DETERMINED BY ASTM D 3161.

FASTENERSFASTENERS FOR ASPHALT SHINGLES SHALL COMPLY WITH ASTM F 1667, AND SHALL BE MADE WITH GALVANIZED STEEL, STAINLESS STEEL OR ALUMINUM WITH A MINIMUM SHANK SIZE OF 12 GAUGE (0.105") WITH A MINIMUM 3/8" DIAMETER HEAD SHANK AND SHALLBE A LENGTH TO PENTRATE THE SHEATHING

THE NAIL COMPONENT OF PLASTIC CAP NAILS SHALL MEET OR EXCEEDTHE REQUIREMENTS OF ASTM A 641, CLASS 1, OR EQUAL, AND SHALL BE CORROSION RESTITANT BY ELECTRO GALVANIZATION, MECHANICAL GALVANIZATION, HOT DIPPED GALVANIZATION OR SHALL BE MADE OF STAINLESS STEEL, NON-FERROUS METAL

ASPHALT SHINGLE ROOF SPEC'S

3

A.P.A. RATED STURDI-FLOOR, EXPOSURE 1, TONGUE & GROOVE EDGESSPAN RATING 48/24 OR BETTER, GLUED AND NAILED

FLOOR SHEATHNG AT 2ND FLOOR

5

R310.2.1 MINMUM OPENING AREA- ALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET (0.530 m2).

EXCEPTION- GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NETCLEAR OPENING OF 5 SQUARE FEET (0.465 m2).

R310.2.1 MINMUM OPENING HEIGHT- THE MINIMUM NET CLEAR OPENINGHEIGHT SHALL BE 24 INCHES (610mm).

R310.2.1 MINMUM OPENING WIDTH- THE MINIMUM NET CLEAR OPENINGWIDTH SHALL BE 20 INCHES (508mm).

R310.1.1 OPERATIONAL CONSTRAINTS- EMERGENCY ESCAPE AND RESCUEOPENINGS SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE USE OF KEYS OR TOOLS.

R310.2.3 WINDOW WELLS- THE MINIMUM HORIZONTAL AREA OF THE WINDOWWELL SHALL BE 9 SQUARE FEET (0.84 m2), WITH A MINIMUM HORIZONTALPROJECTION AND WIDTH OF 36 INCHES (914mm). THE AREA OF THE WINDOWWELL SHALL ALLOW THE EMERGENCY ESCAPE AND RESCUE OPENING TO BE FULLY OPENED.

MINIMUM EGRESS WINDOW DETAIL

1'-8" MIN.

2'-0

" M

IN.

3'-8

" M

AX.

FINISH FLOOR

5.7 SQ. FT. CLEAR OPENING

R703.4 - WHERE FLASHING INSTRUCTIONS OR DETAILS ARE NOT PROVIDED BY THE WINDOW OR DOOR MANUFACTURER OR BY THE FLASHING MANUFACTURER, "PAN FLASHING" SHALL BE INSTALLED AT THE SILL OF EXTERIOR WINDOW AND DOOR OPENINGS. PAN FLASHING SHALL BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT WATER TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER-RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. OPENINGS USING PAN FLASHING SHALL INCORPORATE FLASHING OF PROTECTION AT THE HEAD AND SIDES.

"PAN FLASHING" IS A GENERIC TERM THAT USED TO REFER TO "METAL PAN FLASHING". HOWEVER MANY MODERN MATERIALS HAVE BEEN DEVELOPED FOR THE SAME FUNCTION SUCH AS:- FLEXIBLE PEEL AND STICK FLASHING MEMBRANE-FLUID APPLIED FLASHINGFOR SUCH PRODUCTS FOLLOW THE MANUFACTURER'S INSTALLATION REQUIREMENTS

FOR IN-DEPTH FLASHING INSTRUCTIONS, REFER TO THE FOLLOWING PUBLICATIONS:FMA/AAMA 100FMA/AAMA 200FMA/WDMA 250FMA/AAMA/WDMA 300

INSTALL "PAN" FLASHING AT THE WINDOW SILL

OPENING FOR WINDOW OR DOOR

WHERE "PAN" FLASHING IS USED AT THE SILL, ALSOINCORPORATE FLASHINGOR PROTECTION AT THE HEAD AND SIDES

THE FLASHING INSTRUCTIONS FROM THE WINDOW/ DOOR MFR., OR THE FLASHING MFR.,

SHALL SUPERCEDE THIS DETAIL

PAN FLASHING PER R703.4SCALE: N.T.S.

WALL SHEATHINGWITH HOUSE WRAPOR ZIP SYSTEMWALL SHEATHING

PAPER BACKMETAL LATH

MID WALLWEEP SCREEDOVER FELT STRIPMASONRY NAIL

6" WIDE FELT

MASONRY WALL

WOOD FRAMING EITHERFLOOR TRUSS OR GABLEEND TRUSS

FELT ANDWEEP SCREED

WO

OD F

RAM

EM

ASO

NRY W

ALL

CORNER OFBUILDING

CORNER BEAD

MITER OUT CORNERBEAD AT MID WALLWEEP SCREED

CAULK CENTER JOINT IN MID WALL WEEP SCREED 2" IN EA.DIRECTION AT CORNER

CORNER OFBUILDING

FULLY EMBED BACK FACEOF WEEP SCREED INCAULK. LET OOZE OUT ATCORNER AND SCREED 2"MIN. WIDTH

WIRE LATHWITH FELTOVER FRAMEWALL

EXPANSION JOINT

EXPANSION JOINT OVERWIRE LATH

DECO. TEXTURE FINISHOVER WIRE LATH

WO

OD F

RAM

EM

ASO

NRY W

ALL

MASONRY WALLMASONRY WALL

DECO. TEXTURE FINISHOVER WIRE LATH

EXPANSION JOINT

MASONRY WALL

EXPANSION JOINT

AMICO M-TYPECONTROL JOINTAMCJM-780 ORAPPROVED EQUALOVER LATH (CUTLATH BEHIND CONTROL JOINT 1/4"MIN. GAP) LOCATEOVER STUD ONLYAND PER NOTE 1

*

* NOTE 1:(AT WOODFRAME ONLY)MAX OF 144 SQ. FT.BETWEEN CONTROLJOINTS. NOT GREATERTHAN 18'-0" O.C. MAXAREA RATIO OFCONTROL JOINTS-2-2/1 TO 1

WIRE THE CONTROLJOINT TO LATH WITH18 GA. GALVANIZEDWIRE AT 7' O.C. MAX.

WIRE LATHOVER FELT

FELT PAPER

FRAME WALL

FELT STRIP

WIRE LATH OVERMID WALLWEEP SCREEDOVER FELT STRIPMID WALL

WEEP SCREEDOVER FELT STRIP

MITER OVER SCREED

FELT STRIPOVER BLOCK WALL

BUILDING MASONRY WALL

MID WALL WEEP SCREED DETAIL

WEEP SCREED DETAILINSTALL AT ALL EXTERIOR WALL LOCATIONS WHEREWOOD STUD FRAMING IS ABOVE MASONRY WALLS.

GABLE WALL ROOF

EXTERIOR

ATTICATTICEXTERIOR

HOUSE WRAP

EXTERIOR PLYWOOD W/RADIANT BARRIER ON ATTIC SIDE

EXTERIOR STUDWALL OR TRUSS

RADIANT BARRIERGLUED TO PLYWOOD

TOP CHORD

RADIANT BARRIER: SCALE: N.T.S.

NOTE: EXTERIOR WALLS ADJACENT TO ATTIC SPACE, INCLUDING KNEEWALLS AND GABLE END WALLS, MUST HAVERADIANT BARRIER AND HOUSE WRAP.

8"X8"X16" CONC. BLOCK

CONCRETE FOOTING SEEFOUNDATION PLAN FORSIZE AND REINFORCING.

PRECAST CONCRETE SILL 1/2" DRYWALL W/ TEXTURED WALLS

WOOD BASE

1X2 P.T. FURRING STRIPS @ 24" O.C.W/ INSULATION (MIN. R4.1)

4" CONC. SLAB ON 6 MIL. VISQUEEN VAPOR BARRIER ON MECHANICALLY COMPACTED FILL @ 95%.

DECO. CEMENT FINISHPER ASTM C-926

SILL SET IN MORTAR

SEE ENERGY CODE FORMS FOR INSULATION R-VALUES

1X4 P.T. STRIP

VENTED SOFFITSHALL MEET R703.1.2.1SEE TABLE 3 ON S-3

DRYWALL CEILINGPER NOTE 9 INTABLE 1 ON A-6

GRADE

PROVIDE TERMITE TREATMENT WITH "BORA CARE".

SLOPE TO EXTERIOR

ROOF SHEATHING PER SCHEDULE 2/S-3.AND PER NOTES IN TABLE 2 ON A-6

SHINGLE ROOF PER NOTE 3 ON A-6

EMBEDDED STRAP AT EACHTRUSS PER ROOF FRAMING PLAN.

FLASHING AND DRIP EDGE PER NOTESIN TABLE 2 ON A-6

WINDOW, SEE SCHEDULE AND PLAN.

PRECAST LINTEL SEE FRAMING PLAN

WINDOW BUCKS SEE TABLE 2 ON A-61X4 P.T. BUCK W. BED OF CONTINUOUS CAULK UNDER

PROVIDE VENTILATIONPER R806.1

8"X8" CONTINUOUSBOND BEAM W/1 #5, GROUT SOLID

WOOD TRUSSES @ 24" O.C. (TYPICAL)DESIGNED BY DELEGATED TRUSS ENGINEER.

2X6 MIN. SUB FASCIA

4"

MIN

.

12"

MIN

.D

W

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

Y:\0-N

ew D

ata\

1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\S

UBD

IVIS

IONS\D

EEP

CREEK S

OUTH\1

1571 L

OT 1

4 B

LK 8

16 2

414 A

L\REVIT

\11571 2

414 A

L.rv

t

A-6

SECTIONS

24

14

MO

DEL

JWC

JBL

03/23/20

LOT:

14

BLO

CK:

816

SUBD

IVIS

ION:

DEEP C

REEK S

OUTH

AD

DRS:

23

05 B

ONN C

OURT

D.R

.H.

#:

57

97

00

029

GC

D J

OB #

11

571

Page 9: Community Development For Office Use Only Permit Number · lowest point of garage shall be set above base flood elevation per fema flood map standard sgd recess 1-1/2". impact glass

WH

HB

HB

FOUNDATION

PLAN NOTES:1. TOP OF GROUND FLOOR SLAB DATUM ELEVATION 0'-0"2. "F#" DENOTES CONTINUOUS WALL FOOTING TYPE PER SCHEDULE THIS SHEET.3. PROVIDE #5 VERTICAL REINFORCING AT DOT LOCATIONS SHOWN ON PLAN FROM

FOOTING TO BOND BEAM.4. ALL DIMENSIONS ARE TO OUTSIDE FACE OF MASONRY WALLS. SOME SLAB EDGES

MAY EXTEND BEYOND FACE OF WALL.5. FOR DIMENSIONS OF ROUGH OPENINGS IN MASONRY WALLS, COORDINATE WITH

WINDOW/ DOOR SUPPLIER.

SCALE: 1/4" = 1'-0"

TYPELENGTH WIDTH DEPTH

CONT. 1'-4"

1'-8"

1'-0"

1'-4"

1'-4"

F1

F2

F3

F4

F5

1'-8"

1'-0"

1'-0"

2-#5

SHAPE

WALL FOOTING SCHEDULEUSED BOTTOM

REINFORCING

F6

F6A

TE

CONT.

CONT.

CONT.

CONT.

CONT.

CONT.

CONT.

1'-4"

0'-8"

0'-8" 0'-8"

0'-8"

1'-8"

0'-10"

0'-8"

2-#5

2-#5

2-#5

2-#5

2-#5

1-#5

1-#5

ADD CURB TOGARAGE, SEEDETAIL

TYPE LENGTH WIDTH DEPTH

2'-6" 2'-6"

3'-0"3'-0"

3'-6"3'-6"

4'-0"4'-0"

5'-0"5'-0"

A

B

C

D

E

1'-0"

1'-0"

1'-0"

1'-2"

1'-2"

3-#5 3-#5

4-#5 4-#5

4-#5 4-#5

5-#5 5-#5

6-#5 6-#5

-

-

-

-

-

REMARKSLONG WAY SHORT WAY

BOTTOM REINF.

PAD FOOTING SCHEDULE

USED

1'-8

"

FIN. GRADE

#5 DOWEL WITH

7" HOOK, EMBED

5" MIN.

2 #5 CONT. W/

3" CLEAR COVER.

1'-0"

1'-0"

MIN

.

2'-1

"

1'-8

"

FIN. GRADE

#5 DOWEL WITH

7" HOOK, EMBED

5" MIN. BELOW

GARAGE FLOOR

2 #5 CONT. W/

3" CLEAR COVER.1'-0"

1'-0"

MIN

.

7 5/8"

.

VARIES WITH

SLOPE OF FLOOR

CURB IS OPTIONAL & NOT INCLUDED

IN FOOTING DIMENSIONS

2'-1

"

3" CLEAR COVER2 #5

8"

1'-4"

8"X8" CONC. RIBBON

W/ 1 #5 ROD CONT.

1" 3"

8"

8"

PAVERSMORTAR

14'-4"16'-0"1'-4"10'-0"18'-0"

59'-8"

14'-4"16'-4"29'-0"

55

'-4

"8

"3

'-4

"

16'-8 1/2"1'-3 1/2"11'-4"

59

'-4

"

2'-3

"6

'-3

"2

'-5

1/2

"2

3'-8

1/2

"2

1'-4

"

REF. SPACE

9 1/2"3'-5"12'-1 1/2"

1'-4"13'-8"1'-4"1'-8"16'-0"1'-8"8'-4"1'-4"

SET A/C PAD ABOVE

FLOOD W/ 1'-0"

FREEBOARD PER

FBCR R322.2.1

LOWEST POINT OF GARAGE SHALL BE SET ABOVE

BASE FLOOD ELEVATION PER FEMA FLOOD MAP

STANDARD SGD RECESS 1-1/2". IMPACT

GLASS SGD RECESS RECESS 2-1/2".

PAVERS BY OTHERS

16'-0" X 8'-0" O.H. GARAGE DOOR8'-0" X 8'-0" O.H. GARAGE DOOR

6'-0

"

TIL

E S

HO

WER

RECES

S 3

-1/2

"

5'-0

" TU

B/ S

HW

R

RUN CONDUIT FOR

ELECTRIC AT

ISLAND

PROVIDE 1/4" WATER

LINE @ REF. SPACE

FOR ICE MAKER

5'-0

" TU

B/ S

HW

R

6" X 12" RECESS6" X 12" RECESS

PAVERS BY OTHERS

1'-11"12'-2"1'-11"11'-4"

ELEV. @ 0'-(-4")

ELEV @ 0'-(-4")

ELEV. @ 0'-(-4")

WASHER

9'-9

"3

'-1

0"

3'-1

0"

19

'-3

"

26

'-4

"1

0'-8

"2

2'-4

"

2'-4"11'-2 1/2"46'-1 1/2"

2'-1"2'-7"

3'-5 1/2"5'-5"17'-9"4'-11"16'-2 1/2"2'-5"4'-10"

DBL

SIN

K

INDICATES (1) #5 VERTICAL BARS IN

GROUTED CELL, LAP 25" W/ #5 DOWEL

OUT OF SLAB W/ 7" HOOK INTO TOP

OF OF BOND BEAM @ 48" O.C. MAX

F3 W

/ CU

RB P

F6

F3

F3 W

/ C

URB

F6

F3

F3

F3

F3

F3

F3

F3

F3

F3

F3

F3 F3

F3 PP P

8F8-1B SET AT GARAGE DOOR HEAD

HEIGHT, ADD COUSRING AS,

REQUIRED TO 8X8 BOND BEAM W/ 1#

5, TOP @ 9'-4" GROUT SOLID

NOTE: INSTALL 1-3/8" THICK

SOLID WOOD DOOR BETWEEN

LIVING & GARAGE PER R302.5.1

A

A

A/H

SAWCUT SLAB

PER DETAIL 5/S-3

SET W/H ABOVE FLOOD W/ 1'-0"

FREEBOARD PER FBCR R322.2.1

12

'-6

"

A

AA

B

B

9'-2

"

C

8'-6

"

A

A

7'-0"

AA

A

4'-6

"5

'-6

"1

3'-8

"1

1'-0

"1

2'-0

"

A

B

B

7'-0"

A A

59

'-4

"

F3

7'-0"

F5

OPT.

LT.

PROVIDE TERMITE TREATMENT

WITH "BORA CARE"

RANG

E

DW

59'-8"

3'-4

"8

"5

'-4

"

6'-8

"

11

'-0

"

12'-0"

BRASS FLOOR

OUTLET W/ SWITCH

(2) #5 RODS CONT. W/

3" CLEAR COVER

1'-0

"

1'-4"

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

Y:\0-N

ew D

ata

\1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\S

UBD

IVIS

IONS\D

EEP

CREEK S

OUTH\1

1571 L

OT 1

4 B

LK 8

16 2

414 A

L\REVIT

\11571 2

414 A

L.rv

t

S-1 AL

FOUNDATION PLAN

24

14

MO

DEL

JWC

JBL

03/23/20

LOT:

14

BLO

CK:

816

SUBD

IVIS

ION:

DEEP C

REEK S

OUTH

AD

DRS:

23

05 B

ONN C

OURT

D.R

.H.

#:

57

97

00

029

GC

D J

OB #

11

571

1/2" = 1'-0"

F3 FOOTING

1/2" = 1'-0"

F3 WITH CURB AT GARAGE

1/2" = 1'-0"

F6 STEP DOWN

1/2" = 1'-0"

"P" PAVERS DETAIL ENTRY/LANAI

1/4" = 1'-0"

FOUNDATION PLAN "AL"

PROVIDE CORNER BARS IN FOOTING PER 6/S-3

1/2" = 1'-0"

F5 FOOTING

derek
Seal Transparent
derek
Statement 3
Page 10: Community Development For Office Use Only Permit Number · lowest point of garage shall be set above base flood elevation per fema flood map standard sgd recess 1-1/2". impact glass

WH

HB

HB

D3

EJ4

VG4

V1

V5

V3

V4

V2

V6

V1

V3

V2

CJ6

CJ6

J1A

J2

J2

J2

B1

CJ5

EJ2

J2

J2

B3

A12

A20

A4

A7

A10

A3

A18

A16

A13

A21

J2

J2J2

J2

A11

A6

J6

J6

J6

J6

A15

A23

A19

A9

A17

A22

A8

J4

J4

J4

J4

CJ12 C

J12A

5

A2

A1

EJ6

EJ6

A14

EJ8

EJ8

VG3

D2

J2

J2

J2

J2

D4

CJ9

CJ9

J4

J4

J4

J4

D1

EJ4A

VG2

J2J2

J2

J2

C1

CJ9A

CJ9A

J4J4

J4 J4

VG1

V7

B2

M1

GROUT SOLIDAT HANGER

SIMPSONLGUM210-2-SDS

HANGER

TRUSS D4

SIMPSONHGAM10KTA

EMBEDDED STRAP AT EACH ROOFTRUSS, SEE ROOF PLAN. BREAK

OUT WEB OF BLOCK AS NEEDED TOPROPERLY LOCATE EACH STRAP

ROOF SHEATHING PERSCHEDULE 2/S-3

9'-4"

12'-8"

8"x8" CONTINUOUS MASONRYBOND BEAM w/ 1-#5, GROUTSOLID. PROVIDE CORNER BARSPER DETAIL 6/S-3

#5 VERT. IN GROUTED CELL ATDOT LOCATIONS ON PLAN (48"OC MAX EXTERIOR)

SOFFITS SHALL MEET WINDDESIGN PRESSURES PERR703.1.2.1. FOR FIELD

FRAMING, SEE TABLE 2/S-3

TRUSS C1

1 SCALE: 3/4" = 1'-0"

STRAPPING AT TRUSS D4

PLAN NOTES:

1. ROOF TRUSS BEARING ELEVATION VARIES, SEE

LEGEND.

2. ROOF FRAMING SHALL BE WOOD TRUSSES DESIGNED

BYA DELEGATED TRUSS ENGINEER PER DESIGN

CRITERIA ON SHEET S-3.

3. PROVIDE STRAPPING AT TRUSSES PER NOTES ON THIS

SHEET.

4. FOR NAILING OF ROOF DECK, SEE 1 AND 2 ON S-3.

5. 8F8-1B etc., DENOTES PRECAST LINTEL ABOVE

DOOR/WINDOW OPENING PER SCHEDULE THIS SHEET.

6. AT TRUSS BEARING, PROVIDE 8x8 MASONRY BOND

BEAM W/ 1 #5 CONTINUOUS, SEE DETAIL 11/S-3.

WALL ABOVE WITH BOND

BEAM AT TOP

#5 VERTICAL, ABOVE

LINTEL ONLY WHERE

NOTED ON PLAN

'1B' DENOTES 1#5 BOTTOM

WITH 7" HOOK EACH END OR

EXTEND 24" BEYOND OPENING.

'0B' DENOTES "NO REBAR"

8" PRECAST LINTEL

GROUT SOLID

1'-4" GROUTED

1#5 TOP

1#5 BOTTOM

8F8-1B

8F8-0B

8F16-1B/1T

PRECAST LINTEL AT SWING DOORS, USE 2" RECESS STYLE

LINTEL IF NEEDED FOR ROUGH OPENING.

LINTELS BEAR 4" MIN. EACH END

ROOF SHEATHING

8d RING SHANK @

6" O.C.

16d NAILS

@ 8" O.C.

2" X () BLOCKING W/

BEVEL CUT TOP

ROOF TRUSS

BEVELLED BLOCKING DETAIL

LANAI

NOOK

BEDROOM #2

BEDROOM #3

KITCHENLAUNDRY

3 CAR GARAGE

DINING ROOM

ENTRY

FOYER

BEDROOM #4

MASTER SUITE

MASTER BATH

W.I.C.

GREAT ROOM

REF. SPACE

3'-3"

RIDGE

RID

GE

RID

GE

RID

GE

HIP

HIP

HIPH

IP

HIP

HIP

HIP

VAL

LEY

VAL

LEY

HIP

HIP

HIP

HIP

VAL

LEY V

ALLEY

VALLEY

WHERE ROOF SHEATHING

CONTACTS ONLY THE EDGE

OF ROOF TRUSSES, INSTALL

BEVELLED BLOCKING PER

DETAIL THIS SHEET (DR

HORTON COMPANY

REQUIRMENT)

(+33.5, -36.3) WIND PRESSURES PER

ASCE7-10, 160 MPH, EXPOSURE C, AND

CONVERTED TO ALLOWABLE STRESS

DESIGN PRESSURES USING 0.6W LOAD

FACTOR. (Vasd=124 MPH, RISK CAT II,

ENCLOSED, kd=0.85, H-15'0

8X8 CONTINUOUS MASONRY BOND

BEAM AT TOP OF WALL W/ 1#5

BAR.PROVIDE CORNER BARS PER

8/S-3

CORNER BARS IN BOND

BEAM PER DETAIL 8/S-3

8F8-1B SET GARAGE DOOR HEAD

HEIGHT, ADD COURSING AS REQUIRED

TO 8X8 BOND BEAM W/ 1#5 TOP @

9'-4" ADD VER @ 48" O.C. GROUT

SOLID

8F8-0B8F8-0B

8F8

-0B

8F8

-0B

8F8-0B

8F8-0B

8F8

-0B

8F8-0B

8F8

-0B

THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE &

ATTIC BY NOT LESS THAN 1/2" GYPSUM BOARD APPLIED TO

THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS

SHALL BE SEPARATED WITH NOT LESS THAN 5/8" TYPE "X"

GYPSUM BOARD OR EQUIVALENT. WHERE THE SEPARATION IS

A FLOOR-CEILING ASSEMBLY THE STRUCTURE SUPPORTING THE

SEPARATION SHALL ALSO BE PROTECTED BY NOT LESS THAN

1/2" GYPSUM BOARD OR EQUIVALENT

8F8-1B

8F8-1B

(+28.2 -31.5)

(+28.2 -31.5)

8F8-OB

(+33.5 -36.3)

(+33.5 -36.3)

(+3

3.5

-36

.3)

(+3

3.5

-36

.3)

(+33.5 -36.3) (+33.5 -36.3)

(+33.5 -36.3)

(+33.5 -36.3)

(+33.5 -36.3)

(+3

3.5

-36

.3)

(+3

3.5

-36

.3)

8F8-1B

8F8

-OB

(+3

3.5

-36

.3)

(+33.5 -36.3)

ATTIC ACCESS

BATH #2

BATH #3

1'-0

"

9'-4" FLAT CEILING

12'-8" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

12'-0" FLAT CEILING

12'-0" FLAT CEILING

#5 CORNER BAR IN

BOND BEAM PER 8/S-3

SEE DETAIL 9/S-3 WHERE

LINTEL AS LANAI /ENTRY

INSTERSECTS MAIN WALL,

TYPICAL

2'-0

"

1'-0

"1'-0

"

1-HETA20

@ D4

1-META16

@ D1

HU28 HANGER

@ D3

GABLE BRACE

NOT REQUIRED

OUTLOOKERS

PER 12/S-3

8F16-1B/1T

1-META16

@ B1OUTLOOKERS

PER 12/S-3

NO GABLE BRACE

REQUIRED

1-META16

@ B1

1-META16

@ D1

1-HETA20

@ B3

HU28 HANGER

@ B2&B2A

1-META16

@ A13

LGUM210-2-SDS

@ B3 FILL W/

BLOCKING

MTS16, TYP.

2-2X12 HEADER W/

1-MSTA18 EACH END

& HTT5 BOTTOM

3-HTS20 @A23

3-2X6 POST HTT5

BOTTOM

STUD BEARING WALLS, 2X4 OR 2X6

SPF # 2 @ 16" O.C. WITH BLOCKING

AT MID POINT, SPH4 OR SPH6 TOP

AND BOTTOM AT 16" O.C. PT SILL

PLATE WITH 1/2"X6" EXPANSION BOLT

@ 32" O.C. WITH 2" WASHER

SIMPSON LGUM210-2-SDS

@ GIRDER D4, GROUT CELLS

SOLID AT HANGER

1-META16,

TYP.

1-HETA20

@ A1

8F16-1B/1T

1-META16,

TYP.

8F8-1B

1-META16

@ A13

8F16-1B/1T

1-META16

@ A13

EXTERIOR CEILING PER

SCHEDULE 2/S-3

1-META16

@ A23

1-META16,

TYP.

13

S-3 13

S-3

FILED FRAME

CRICKET

FILED FRAME

CRICKET

SIM

2-MTS16

@ A21 &

A22

2-HTS20

@ A15

BEARING HEIGHT

= BEARING @ 9'-4"

= INTERIOR BEARING @ 9'-4"

= BEARING @ 12'-8"

= INTERIOR BEARING @ 12'-8"

TRUSS STRAPPING TO MASONRY

MAX TRUSS UPLIFT

@ 24" OC (LBS)CONNECTOR FASTENER

1450

1810

2120

1875 (1 PLY)

1795 (2 PLY)

2365 (2 PLY)

2365 (2 PLY)

3965/SYP 3330/SPF

4235/SYP 3640/SPF

4670/SYP 4015/SPF

5445/SYP 5360/SPF

10690/SYP 10690/SPF

10790/SYP 10790/SPF

(1) META16 TO 40

(1) HETA16 TO 40

(1) HHETA16 TO 40

(2) META16 TO 40

(2) META16 TO 40

(2) HETA16 TO 40

(2) HHETA12 TO 40

MGT (2 PLY)

HTT4

HTT5

HTT5KT

(1)HGT - 2

(1)HGT - 3

(8) 0.148x11/2 ", EMBED 4"

(9) 0.148x11/2", EMBED 4"

(10) 0.148x11/2", EMBED 4"

(10) 0.148x11/2", EMBED 4"

(14) 0.162x31/2", EMBED 4"

(12) 0.162x31/2", EMBED 4"

(12) 0.162x,31/2" EMBED 4"

(22) 0148x3" ATR, EPOXY 12"

(18) 0.162x21/2", 5/8" ATR, EPOXY 12"

(26) 0.148x3", 5/8", ATR, EPOXY 12"

(26) SD#10x21/2, 5/8," ATR, EPOXY

(26) 0.148x3" TO GIRDER

(2) 3/4" Ø ATR, EPOXY 12"

(16) 0.148x3" TO GIRGER,

(2) 3/4" Ø ATR, EPOXY 12"

INSTALL

META16 AT

ALL

TRUSSES

TO 1450 lb

UPLIFT. FOR

HIGHER

UPLIFTS,

SEE NOTES

ON PLAN.

NOTES:

1. PROVIDE A STRAP FROM THE ABOVE LIST AT EACH ROOF TRUSS BEARING POINT, BASED

ON THE TRUSS UPLIFT VALUES IN THE SIGNED AND SEALED TRUSS DESIGN PACKAGE AND

SUITABLE FOR THE GEOMETRY. EMBED STRAP ON -C OF WALL.

2. CONNECTORS ARE SIMPSON STRUCTURAL CONNECTORS. ALL CONNECTORS SHALL BE

INSTALLED IN STRICT ACCORDANCE WITH SIMPSON PRINTED INSTUCTIONS.

SUBSTITUTIONS MUST BE APPROVED IN WRITING BY THE ENGINEER OF RECORD.

3. WHERE EMBEDDED STRAPS ARE MISSING, OR MIS-LOCATED, INSTALL RETROFIT STRAP PER

10/S-3.

R4-021020

TRUSS STRAPPING TO STUDWALL/ WOOD BEAM

MAX TRUSS UPLIFT

@ 24" OC (LBS)CONNECTOR FASTENER

850

1700

2550

1125

2250

3375

4500

(1)MTS16 TO 20

(2) MTS16 TO 20

(3) MTS16 T0 20

(1) HTS20 TO 30

(2) HTS20 TO 30

(3) HTS20 TO 30

(4) HTS20 TO 30

(14) 10dx1-1/2"

(14) 10dx1-1/2"

(14) 10dx1-1/2"

(24) 10dx1-1/2"

(24) 10dx1-1/2"

(24) 10dx1-1/2"

(24) 10dx1-1/2"

INSTALL AT ALL

TRUSSES TO

840 lb UPLIFT.

FOR HIGHER

UPLIFTS, SEE

NOTES ON

PLAN.

NOTES:

1. PROVIDE A STRAP FROM THE ABOVE LIST AT EACH ROOF TRUSS BEARING

POINT, BASED ON THE TRUSS UPLIFT VALUES IN THE SIGNED AND SEALED

TRUSS DESIGN PACKAGE.

2. CONNECTORS ARE SIMPSON SRTONG TIE. ALL CONNECTORS SHALL BE

INSTALLED IN STRICT ACCORDANCE WITH SIMPSON PRINTED INSTUCTIONS.

R2

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

Y:\0-N

ew D

ata

\1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\S

UBD

IVIS

IONS\D

EEP

CREEK S

OUTH\1

1571 L

OT 1

4 B

LK 8

16 2

414 A

L\REVIT

\11571 2

414 A

L.rv

t

S-2 AL

ROOF FRAMING PLAN

24

14

MO

DEL

JWC

JBL

03/23/20

LOT:

14

BLO

CK:

816

SUBD

IVIS

ION:

DEEP C

REEK S

OUTH

AD

DRS:

23

05 B

ONN C

OURT

D.R

.H.

#:

57

97

00

029

GC

D J

OB #

11

571

1/4" = 1'-0"

ROOF FRAMING PLAN "AL"

TRUSS BEARING CONDITIONS AND

STRAPPING IS BASED ON TRUSS

LAYOUT PREPARED BY SCOSTA

JOB # 44142 DATED: 08/15/18

REVISED: 01/14/2020

derek
Seal Transparent
Page 11: Community Development For Office Use Only Permit Number · lowest point of garage shall be set above base flood elevation per fema flood map standard sgd recess 1-1/2". impact glass

” ”

” ”

derek
Seal Transparent