16
Technical Data CompactLogix 5380 Controllers Specifications Catalog Numbers 5069-L306ER, 5069-L306ERM, 5069-L310ER, 5069-L310ER-NSE, 5069-L310ERM, 5069-L320ER, 5069-L320ERM, 5069- L330ER, 5069-L330ERM, 5069-L340ER, 5069-L340ERM The CompactLogix™ 5380 controllers are part of the Logix5000™ family of controllers. The controllers provide a scalable controller solution to address a wide variety of applications. The controllers are DIN rail mounted. CompactLogix 5380 controllers can monitor and control local and remote I/O modules, and other devices connected to an EtherNet/IP network. The controllers provide the following functionality: Two EtherNet/IP ports with the option to use Dual-IP mode or Linear/DLR mode Use of 5069 Compact I/O™ module as local I/O modules One USB port Use of 1784-SD1 or 1784-SD2 Secure Digital (SD) card for nonvolatile memory Support for Integrated Motion over an EtherNet/IP network (not all CompactLogix 5380 controllers) Topic Page Summary of Changes 2 Controller Use With Other Devices 8 Ethernet Node Limits 10 CompactLogix 5380 Controller Accessories 11 Additional Resources 14

CompactLogix 5380 Controllers Specifications Technical Data

  • Upload
    others

  • View
    13

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CompactLogix 5380 Controllers Specifications Technical Data

Technical Data

CompactLogix 5380 Controllers Specifications

Catalog Numbers 5069-L306ER, 5069-L306ERM, 5069-L310ER, 5069-L310ER-NSE, 5069-L310ERM, 5069-L320ER, 5069-L320ERM, 5069-L330ER, 5069-L330ERM, 5069-L340ER, 5069-L340ERM

The CompactLogix™ 5380 controllers are part of the Logix5000™ family of controllers. The controllers provide a scalable controller solution to address a wide variety of applications. The controllers are DIN rail mounted.

CompactLogix 5380 controllers can monitor and control local and remote I/O modules, and other devices connected to an EtherNet/IP network. The controllers provide the following functionality:

• Two EtherNet/IP ports with the option to use Dual-IP mode or Linear/DLR mode

• Use of 5069 Compact I/O™ module as local I/O modules

• One USB port

• Use of 1784-SD1 or 1784-SD2 Secure Digital (SD) card for nonvolatile memory

• Support for Integrated Motion over an EtherNet/IP network (not all CompactLogix 5380 controllers)

Topic Page

Summary of Changes 2

Controller Use With Other Devices 8

Ethernet Node Limits 10

CompactLogix 5380 Controller Accessories 11

Additional Resources 14

Page 2: CompactLogix 5380 Controllers Specifications Technical Data

CompactLogix 5380 Controllers Specifications

Summary of Changes

This publication revision includes information about the following CompactLogix 5380 controllers:• 5069-L306ER, 5069-L306ERM• 5069-L310ER, 5069-L310ER-NSE, 5069-L310ERM• 5069-L320ERM• 5069-L330ER, 5069-L330ERM• 5069-L340ER

Features - CompactLogix 5380 Controllers

Feature5069-L306ER, 5069-L306ERM

5069-L310ER, 5069-L310ER-NSE, 5069-L310ERM

5069-L320ER, 5069-L320ERM

5069-L330ER,5069-L330ERM

5069-L340ER,5069-L340ERM

Controller tasks

• Continuous

• Periodic

• Event

32 tasks

1000 programs/task

All event triggers

Built-in communication ports

1 USB port

2 EtherNet/IP ports

IMPORTANT: Consider the following:– When the controller operates in Dual-IP mode, each Ethernet port requires a unique IP address.– When the controller operates in Linear/DLR mode, the controller uses only one IP address.

USB port communication

USB 2.0, Type B

Full speed (12 Mbps)

Programming, configuration, firmware flash, and on-line edits only

Ethernet performance10 Mbps, 100 Mbps, 1 Gbps

Full Duplex only

EtherNet/IP modes supportedDual-IP mode (Available with the Logix Designer application, version 29.00.00 or later)

Linear/DLR mode

EtherNet/IP network topologies supported• DLR• Star• Linear

EtherNet/IP nodes supported, max 16 24 40 50 55

Socket interfaces supported, max 32

Integrated motion5069-L306ERM controller only –

As many as 2 axes

5069-L310ERM controller only –

As many as 4 axes

5069-L320ERM controller only –

As many as 8 axes

5069-L330ERM controller only –

As many as 16 axes

5069-L340ERM controller only –

As many as 20 axes

Programming languages

Ladder Diagram (LD)

Structured Text (ST)

Function Block Diagram (FBD)

Sequential Function Chart (SFC)

Integrated safety N/A

2 Rockwell Automation Publication 5069-TD002B-EN-P - July 2016

Page 3: CompactLogix 5380 Controllers Specifications Technical Data

CompactLogix 5380 Controllers Specifications

Technical Specifications - CompactLogix 5380 Controllers

Attribute5069-L306ER, 5069-L306ERM

5069-L310ER, 5069-L310ER-NSE, 5069-L310ERM

5069-L320ER, 5069-L320ERM

5069-L330ER,5069-L330ERM

5069-L340ER,5069-L340ERM

Controller capacity 0.6 MB 1 MB 2 MB 3 MB 4 MB

Optional nonvolatile memory1784-SD1 card

1784-SD2 card (shipped with the controller)

Local I/O modules, max 8 8 16 31 31

Module Power bus (MOD Power) voltage range

18…32V DC

Module Power bus (MOD Power) current, max 450 mA

Module Power bus (MOD Power) inrush 850 mA for 125 ms

Module Power bus (MOD Power) Passthrough voltage range

18…32V DC

Module Power bus (MOD Power) current rating, max(1) 9.55 A

Sensor Actuator (SA) Field Power voltage ranges

0…32V DC

0…240V AC, 47…63 Hz

ATEX/IECEX, 125V AC max

Sensor Actuator (SA) Field Power current, max 10 mA (DC power)

25 mA (AC power)

Sensor Actuator Power bus (SA Power) Passthrough voltage ranges

0…32V DC

0…240V AC, 47…63 Hz

ATEX/IECEX, 125V AC max

Sensor Actuator Power bus (SA Power) current rating, max(2)

9.95 A (DC power)

9.975 A (AC power)

Power dissipation, max 8.5 W

Thermal dissipation, max 29 BTU/hr

Isolation voltage

300V (continuous), Basic Insulation Type, SA and MOD Power to Backplane

300V (continuous), Basic Insulation Type, SA to MOD Power

300V (continuous), Basic Insulation Type, Ethernet to Backplane

300V (continuous), Double Insulation Type, Ethernet to MOD Power

300V (continuous), Double Insulation Type, Ethernet to SA Power

50V (continuous), Functional Insulation Type, Ethernet to USB

300V (continuous), Basic Insulation Type, USB to Backplane

300V (continuous), Double Insulation Type, USB to MOD Power

300V (continuous), Double Insulation Type, USB to SA Power

No isolation between Ethernet ports

Type tested at 1500V AC for 60 s

Rockwell Automation Publication 5069-TD002B-EN-P - July 2016 3

Page 4: CompactLogix 5380 Controllers Specifications Technical Data

CompactLogix 5380 Controllers Specifications

Weight, approx 0.768 kg (1.693 lb)

Dimensions (HxWxD), approx 143.97 x 98.10 x 136.81 mm (5.67 x 3.86 x 5.39 in.)

Location DIN rail mount (horizontal mount only)

DIN railCompatible zinc-plated, chromate steel DIN rail.

EN50022 - 35 x 7.5 mm (1.38 x 0.30 in.)

Removable terminal block

RTBs are available in separately-ordered 5069 RTB kits. The MOD power connection uses a 4-point RTB, and the SA power connection uses a 6-point RTB. The following kits are available:

• Kit catalog number 5069-RTB64-SCREW contains RTB catalog numbers 5069-RTB6-SCREW and 5069-RTB4-SCREW

• Kit catalog number 5069-RTB64-SPRING contains RTB catalog numbers 5069-RTB6-SPRING and 5069-RTB4-SPRING

Terminal block torque5069-RTB4-SCREW & 5069-RTB6-SCREW: 0.4 N•m (3.5 lb•in)

5069-RTB4-SPRING & 5069-RTB6-SPRING: N/A

Wire size

5069-RTB4-SCREW, 5069-RTB6-SCREW connections:

0.5…1.5 mm2 (22…16 AWG) solid or stranded copper wire rated at 105 °C (221 °F), or greater, 3.5 mm (0.14 in.) max diameter including insulation, single wire connection only

5069-RTB4-SPRING, 5069-RTB6-SPRING connections:

0.5…1.5 mm2 (22…16 AWG) solid or stranded copper wire rated at 105 °C (221 °F), or greater, 2.9 mm (0.11 in.) max diameter including insulation, single wire connection only

Ethernet connections:

Ethernet Cabling and Installation according to IEC 61918 and IEC 61784-5-2

Insulation stripping length5069-RTB4-SCREW, 5069-RTB6-SCREW connections: 12 mm (0.47 in.)

5069-RTB4-SPRING, 5069-RTB6-SPRING connections: 10 mm (0.39 in.)

Wire category(3)3 - on USB port

1 - on power ports

2 - on Ethernet ports

Enclosure None (open-style)

North American temperature code T4

ATEX temperature code T4

IECEx temperature code T4

(1) Maximum level of MOD Power current that the module can pass through to the next module in the system. The specific level of current passed through varies based on system configuration. You must limit the external power

supply that provides MOD power to 10 A, max, at 18…32V DC.

(2) Maximum level of SA Power current that the module can pass through to the next module in the system. The specific level of current passed through varies based on system configuration. You must limit the external power

supply that provides SA power to 10 A, max at 18…32V DC in DC applications and to 10 A, max at 18…240V AC in AC applications.

(3) Use this Conductor Category information for planning conductor routing. See the Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.

Technical Specifications - CompactLogix 5380 Controllers

Attribute5069-L306ER, 5069-L306ERM

5069-L310ER, 5069-L310ER-NSE, 5069-L310ERM

5069-L320ER, 5069-L320ERM

5069-L330ER,5069-L330ERM

5069-L340ER,5069-L340ERM

4 Rockwell Automation Publication 5069-TD002B-EN-P - July 2016

Page 5: CompactLogix 5380 Controllers Specifications Technical Data

CompactLogix 5380 Controllers Specifications

Environmental Specifications - CompactLogix 5380 Controllers

Attribute5069-L306ER, 5069-L306ERM, 5069-L310ER, 5069-L310ER-NSE, 5069-L310ERM, 5069-L320ER, 5069-L320ERM, 5069-L330ER, 5069-L330ERM, 5069-L340ER, 5069-L340ERM

Temperature, operating

IEC 60068-2-1 (Test Ad, Operating Cold),

IEC 60068-2-2 (Test Bd, Operating Dry Heat),

IEC 60068-2-14 (Test Na, Operating Thermal Shock)

0 °C < Ta < +60 °C

(+32 °F <Ta < +140 °F)

Temperature, nonoperating

IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold),

IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat),

IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock)

-40…+85 °C

(-40…+185 °F)

Temperature, surrounding air, max 60 °C (140 °F)

Relative humidity

IEC 60068-2-30 (Test Db, Unpackaged Damp Heat)5…95% noncondensing

Vibration

IEC 60068-2-6 (Test Fc, Operating)5 g @ 10…500 Hz

Shock, operating

IEC 60068-2-27 (Test Ea, Unpackaged Shock)30 g

Shock, nonoperating

IEC 60068-2-27 (Test Ea, Unpackaged Shock)50 g

Emissions IEC 61000-6-4

ESD immunity

IEC 61000-4-2

6 kV contact discharges

8 kV air discharges

Radiated RF immunity

IEC 61000-4-3

10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz

10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz

10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz

3V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz

EFT/B immunity

IEC 61000-4-4

± 4 kV at 5 kHz on power ports

± 2 kV at 5 kHz on Ethernet ports

Surge transient immunity

IEC 61000-4-5

± 1 kV line-line (DM) and ± 2 kV line-earth (CM) on power ports

± 2 kV line-earth (CM) on Ethernet ports

Conducted RF immunity

IEC 61000-4-610 Vrms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz

Voltage variation

IEC 61000-4-2910 ms interruption on MOD Power port

Rockwell Automation Publication 5069-TD002B-EN-P - July 2016 5

Page 6: CompactLogix 5380 Controllers Specifications Technical Data

CompactLogix 5380 Controllers Specifications

Certifications - CompactLogix 5380 Controllers

Certification(1)

(1) See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.

5069-L306ER, 5069-L306ERM, 5069-L310ER, 5069-L310ER-NSE, 5069-L310ERM, 5069-L320ER, 5069-L320ERM, 5069-L330ER, 5069-L330ERM, 5069-L340ER, 5069-L340ERM

c-UL-usUL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584.

UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810.

CE

European Union 2004/108/EC EMC Directive, compliant with:

• EN 61326-1; Meas./Control/Lab., Industrial Requirements

• EN 61000-6-2; Industrial Immunity

• EN 61000-6-4; Industrial Emissions

• EN 61131-2; Programmable Controllers (Clause 8, Zone A & B)

European Union 2006/95/EC LVD, compliant with:• EN 61010-2-201; Control Equipment Safety Requirements

RCMAustralian Radiocommunications Act, compliant with:• EN 61000-6-4; Industrial Emissions

Ex

European Union 94/9/EC ATEX Directive, compliant with:

• EN 60079-0; General Requirements

• EN 60079-15; Potentially Explosive Atmospheres, Protection "n"

• II 3 G Ex nA IIC T4 Gc

• DEMKO 15 ATEX 1455X

when used at or below 125V AC

IECEx

IECEx System, compliant with:

• IEC 600079-0: General Requirements

• IEC 60079-15; Potentially Explosive Atmospheres, Protection "n"

• II 3 G Ex nA IIC T4 Gc

• IECEx UL 15.0007X

when used at or below 125V AC

KCKorean Registration of Broadcasting and Communications Equipment, compliant with:• Article 58-2 of Radio Waves Act, Clause 3

EtherNet/IP ODVA conformance tested to EtherNet/IP specifications

6 Rockwell Automation Publication 5069-TD002B-EN-P - July 2016

Page 7: CompactLogix 5380 Controllers Specifications Technical Data

CompactLogix 5380 Controllers Specifications

Controller Minimum Spacing Requirements

The minimum distance between the CompactLogix 5380 system and enclosure walls, wireways, and adjacent equipment varies based on the current operating temperature. The minimum distance on all sides of the system is as follows:

• 50.80 mm (2.00 in.) at 55 °C (131 °F)• 101.60 mm (4.00 in) at 60 °C (140 °F)

Controller Dimensions

IMPORTANT CompactLogix 5380 systems can only be mounted horizontally.

Top

Bottom

SideSide

5380

Con

trol

ler

5069

Com

pact

I/O™

End cap

5069

Com

pact

I/O

98.10 mm(3.86 in.)

137.84 mm(5.43 in.)

123.00 mm(4.84 in.)

143.97 mm(5.67 in.)

136.81 mm(5.39 in.)

130.31 mm(5.13 in.)

101.66 mm(4.00 in.)

Rockwell Automation Publication 5069-TD002B-EN-P - July 2016 7

Page 8: CompactLogix 5380 Controllers Specifications Technical Data

CompactLogix 5380 Controllers Specifications

Controller Use With Other Devices

Your controller can control and communicate with the following devices:

• Control I/O Modules

• Communicate with Display Devices

• Communicate with Other Controllers

Control I/O Modules

The CompactLogix 5380 controllers can monitor and control local and remote I/O modules.

Local I/O Modules

A CompactLogix 5380 system uses 5069 Compact I/O modules as its local I/O modules. The number of local I/O modules that are supported in a CompactLogix 5380 system varies by controller catalog number.

Remote I/O Modules

The controller can connect to these remote I/O modules over an EtherNet/IP network.

Cat. No. Local 5069 Compact I/O Modules Supported, Max

5069-L306ER,

5069-L306ERM8

5069-L310ER,

5069-L310ER-NSE,

5069-L310ERM

8

5069-L320ER,

5069-L320ERM16

5069-L330ER,

5069-L330ERM31

5069-L340ER,

5069-L340ERM31

IMPORTANT For maximum performance, we recommend that you use 5069 Compact I/O modules when you use remote I/O modules.

Module Type I/O Module Family

Chassis-based I/O 1746 SLC™ I/O

1756 ControlLogix® I/O

1769 Compact I/O

5069 Compact I/O

In-cabinet I/O 1734 POINT I/O™

1794 FLEX™ I/O

On-Machine™ I/O 1732 ArmorBlock® I/O

1738 ArmorPOINT® I/O

8 Rockwell Automation Publication 5069-TD002B-EN-P - July 2016

Page 9: CompactLogix 5380 Controllers Specifications Technical Data

CompactLogix 5380 Controllers Specifications

Communicate with Display Devices

The controller can communicate with these display devices over an EtherNet/IP network.

Communicate with Other Controllers

The controller can communicate with these programmable controllers.

Device Type Display

Industrial computers

Allen-Bradley® integrated-display rotating media (HDD) and solid-state (SSD) computers

Allen-Bradley integrated-display computers with keypad

Allen-Bradley non-display computers

Graphic terminalsPanelView™ Plus and PanelView CE terminals

PanelView standard terminals

Message displays InView™ message displays

Controller Type Controller Family

Programmable automation controller

CompactLogix 5370

CompactLogix 5380

Compact GuardLogix® 5370 (safety)

ControlLogix 5570

ControlLogix 5580

GuardLogix 5570 (safety)

1756 Armor™ ControlLogix (safety)

1756 Armor GuardLogix (safety)

1768 Compact GuardLogix (safety)

1768 CompactLogix

1769 Modular CompactLogix

1769 Packaged CompactLogix

Programmable logic controllers

1789 SoftLogix™ 5800

PowerFlex® with DriveLogix™

1785 PLC-5®(1)

(1) These controllers require a built-in Ethernet port or a 1761-NET-ENI, EtherNet/IP RS-232-C interface to communicate

with a CompactLogix 5380 controller over an EtherNet/IP network.

1747 SLC™(1)

1761 MicroLogix™(2)

(2) These controllers require a 1761-NET-ENI, EtherNet/IP RS-232-C interface to communicate with a

CompactLogix 5380 controller over an EtherNet/IP network.

1762 MicroLogix(2)

1763 MicroLogix

1764 MicroLogix(2)

1766 MicroLogix

Rockwell Automation Publication 5069-TD002B-EN-P - July 2016 9

Page 10: CompactLogix 5380 Controllers Specifications Technical Data

CompactLogix 5380 Controllers Specifications

Ethernet Node Limits

When you configure a CompactLogix 5380 control system, you must account for the number of Ethernet nodes that you include in the I/O configuration section in the Studio 5000 Logix Designer® application project.

Maximum Number of Ethernet Nodes

The number of nodes that are supported in a Logix Designer application project varies by CompactLogix 5380 controller.

Any devices that you add directly to the I/O configuration section are counted toward the Ethernet node limit. The following are examples of devices that must be counted:

• Remote communication adapters

• Devices with an embedded EtherNet/IP port, such as I/O modules, drives, and linking devices

• Remote controllers when a produce/consume connection is established between the two controllers

• HMI devices that are included in the I/O configuration tree

• Third-party devices that are directly connected to the EtherNet/IP network

Cat. No. Ethernet Nodes Supported

5069-L306ER,

5069-L306ERM16

5069-L310ER,

5069-L310ER-NSE,

5069-L310ERM

24

5069-L320ER,

5069-L320ERM40

5069-L330ER,

5069-L330ERM50

5069-L340ER,

5069-L340ERM55

10 Rockwell Automation Publication 5069-TD002B-EN-P - July 2016

Page 11: CompactLogix 5380 Controllers Specifications Technical Data

CompactLogix 5380 Controllers Specifications

CompactLogix 5380 Controller Accessories

The following accessories are used with a CompactLogix 5380 controller:

• End Cap

• Memory Cards

• Removable Terminal Kits

• Ethernet Communication Cables

End Cap

You must install an end cap, catalog number 5069-ECR, on the right side of the last module in a CompactLogix 5380 system. The end cap is shipped with the controller.

Memory Cards

Memory cards, also known as Secure Digital (SD) cards, offer nonvolatile memory to store a user program and tag data on a controller. Through the Logix Designer application, you can manually trigger the controller to save to or load from nonvolatile memory or configure the controller to load from nonvolatile memory on powerup.

A 1784-SD2 card ships with the controller. If you need additional SD cards, we recommend that you use one that is available from Rockwell Automation. The 1784-SD1 (1 GB) and 1784-SD2 (2 GB) cards are available.

SHOCK HAZARD: The end cap covers the exposed interconnections on the last module in the system. If you do not install the

end cap before powering the system, equipment damage or injury from electric shock can result.

Technical Specifications - 1784-SD1, 1784-SD2

Attribute 1784-SD1 1784-SD2

Memory 1 GB 2 GB

Supported controllers CompactLogix 5380 controllers

Weight, approx 1.76 g (0.062 oz)

Rockwell Automation Publication 5069-TD002B-EN-P - July 2016 11

Page 12: CompactLogix 5380 Controllers Specifications Technical Data

CompactLogix 5380 Controllers Specifications

Environmental Specifications - 1784-SD1, 1784-SD2 Cards

Attribute 1784-SD1, 1784-SD2

Temperature, operating

IEC 60068-2-1 (Test Ad, Operating Cold),

IEC 60068-2-2 (Test Bd, Operating Dry Heat),

IEC 60068-2-14 (Test Nb, Operating Thermal Shock)

-40…+85 °C (-13…+185 °F)

Temperature, storage

IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold),

IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat),

IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock)

-65…+150 °C (-85…+302 °F)

Relative humidity

IEC 60068-2-30 (Test Db, Unpackaged Damp Heat)5…95% noncondensing

Vibration

IEC 60068-2-6 (Test Fc, Operating)15 g peak to peak

Shock, operating

IEC 60068-2-27 (Test Ea, Unpackaged Shock)30 g

Shock, nonoperating

IEC 60068-2-27 (Test Ea, Unpackaged Shock)50 g

Emissions IEC 61000-6-4

ESD immunity

IEC 61000-4-2

6 kV contact discharges

8 kV air discharges

Radiated RF immunity

IEC 61000-4-3

10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz

10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz

10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz

3V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz

Certifications - 1784 Memory Cards

Certification(1)

(1) When marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.

1784-SD1, 1784-SD2

CE

European Union 2004/108/EC EMC Directive, compliant with:

• EN 61000-6-4; Industrial Emissions

• EN 61326-1; Meas./Control/Lab., Industrial Requirements

• EN 61000-6-2; Industrial Immunity

• EN 61131-2; Programmable Controllers (Clause 8, Zone A & B)

RCMAustralian Radiocommunications Act, compliant with: • AS/NZS CISPR 11; Industrial Emissions

KCKorean Registration of Broadcasting and Communications Equipment, compliant with:• Article 58-2 of Radio Waves Act, Clause 3

12 Rockwell Automation Publication 5069-TD002B-EN-P - July 2016

Page 13: CompactLogix 5380 Controllers Specifications Technical Data

CompactLogix 5380 Controllers Specifications

Removable Terminal Kits

You must order 5069 RTB kits to connect MOD power and SA power to CompactLogix 5380 controllers. The MOD power connection uses a 4-point RTB, and the SA power connection uses a 6-point RTB. The following kits are available.

Ethernet Communication Cables

CompactLogix 5380 Controllers Removable Terminal Block Kits

Cat. No. Description

5069-RTB64-SCREW

Contains the following:

• 5069-RTB6-SCREW - 6-point RTB that uses screw-type terminals

• 5069-RTB4-SCREW - 4-point RTB that use screw-type terminals

5069-RTB64-SPRING

Contains the following:

• 5069-RTB6-SPRING - 6-point RTB that uses spring-type terminals to connect SA power to the controller.

• 5069-RTB4-SPRING - 4-point RTB that uses spring-type terminals to connect MOD power to the controller.

Attribute Value

Connector type RJ45 male to RJ45 male

Connector angle Straight-through

Length Varies by catalog number

Connector Number Color

1585J 8-pin Cables with Support for 10/100/1000 Mbps

1585J 8-pin Cables with Support for 10/100 Mbps

1585J 4-pin Cables with Support for 10/100 Mbps

1 White/Orange BI_DA+ TxData +

2 Orange BI_DA- TxData -

3 White/Green BI_DB+ Recv Data +

4 Blue BI_DC+ Unused N/A

5 White/Blue BI_DC- Unused N/A

6 Green BI_DB- Recv Data -

7 White/Brown BI_DD+ Unused N/A

8 Brown BI_DD- Unused N/A

Rockwell Automation Publication 5069-TD002B-EN-P - July 2016 13

Page 14: CompactLogix 5380 Controllers Specifications Technical Data

CompactLogix 5380 Controllers Specifications

Additional Resources

These documents contain additional information concerning related products from Rockwell Automation.

You can view or download publications at http://www.rockwellautomation.com/global/literature-library/overview.page. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative.

Resource Description

5069 Compact I/O Modules Specifications Technical Data, publication 5069-TD001Provides specifications, wiring diagrams, and functional block diagrams for 5069 Compact I/O modules.

CompactLogix Controllers Selection Guide, publication 1769-SG001Provides information about how to design and select components for your CompactLogix controller system.

CompactLogix 5380 Controllers User Manual, publication 5069-UM001 Provides information on how to use CompactLogix 5380 controllers.

5000 Series Digital I/O Module User Manual, publication 5000-UM004Provides information on how to install, configure, and operate 5000 Series digital I/O modules.

5000 Series Analog I/O Module User Manual, publication 5000-UM005Provides information on how to install, configure, and operate 5000 Series analog I/O modules.

5000 Series High-speed Counter Module User Manual, publication 5000-UM006Provides information on how to install, configure, and operate 5000 Series high-speed counter modules.

Replacement Guidelines: Logix5000 Controllers Reference Manual,

publication 1756-RM100

Provides guidelines on how to replace the following:• ControlLogix 5560/5570 controller with a ControlLogix 5580 controller• CompactLogix 5370 L3 controllers with a CompactLogix 5380 controller

EtherNet/IP Communication Modules in Logix5000 Control Systems User Manual, publication ENET-UM004

Provides information on how to use 5000 Series EtherNet/IP communication modules.

Integrated Architecture® and CIP Sync Configuration Application Technique, publication IA-AT003

Provides information on CIP Sync and the IEEE 1588-2008 Precision Time Protocol.

Integrated Architecture Tools website, http://www.rockwellautomation.com/global/products-technologies/integrated-architecture/tools/overview.page

Provides information on tools that you can use in the selection, development, commissioning, and maintenance stages of the integrated architecture lifecycle.

Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 Provides general guidelines for installing a Rockwell Automation industrial system.

Product Certifications website, http://www.rockwellautomation.com/global/certification/overview.page

Provides declarations of conformity, certificates, and other certification details.

14 Rockwell Automation Publication 5069-TD002B-EN-P - July 2016

Page 15: CompactLogix 5380 Controllers Specifications Technical Data

CompactLogix 5380 Controllers Specifications

Notes:

Rockwell Automation Publication 5069-TD002B-EN-P - July 2016 15

Page 16: CompactLogix 5380 Controllers Specifications Technical Data

Allen-Bradley, Armor, ArmorBlock, ArmorPOINT, Compact I/O, CompactLogix, ControlLogix, DriveLogix, FactoryTalk, FLEX, GuardLogix, Integrated Architecture, InView, LISTEN. THINK. SOLVE, Logix5000, MicroLogix, On-Machine,

PanelView, PLC-5, POINT I/O, PowerFlex, Rockwell Automation, Rockwell Software, SLC, SoftLogix, and Studio 5000 Logix Designer are trademarks of Rockwell Automation, Inc.

Trademarks not belonging to Rockwell Automation are property of their respective companies.

Publication 5069-TD002B-EN-P - July 2016

Rockwell Automation SupportUse the following resources to access support information.

Documentation FeedbackYour comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete the How Are We Doing? form at http://literature.rockwellautomation.com/idc/groups/literature/documents/du/ra-du002_-en-e.pdf.

Technical Support Center Knowledgebase Articles, How-to Videos, FAQs, Chat, User Forums, and Product Notification Updates.

www.rockwellautomation.com/knowledgebase

Local Technical Support Phone Numbers Locate the phone number for your country.www.rockwellautomation.com/global/support/get-support-now.page

Direct Dial CodesFind the Direct Dial Code for your product. Use the code to route your call directly to a technical support engineer.

www.rockwellautomation.com/global/support/direct-dial.page

Literature Library Installation Instructions, Manuals, Brochures, and Technical Data.

www.rockwellautomation.com/literature

Product Compatibility and Download Center (PCDC)

Get help determining how products interact, check features and capabilities, and find associated firmware.

www.rockwellautomation.com/global/support/pcdc.page

Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page.

Supersedes Publication 5069-TD002A-EN-P - May 2016 Copyright © 2016 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.