25
Dear Sir, We are pleased to introduce ourselves that Himech Acoustics Engineering is situated in the engineering city, Trichy, Tamilnadu, India. Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile in the attachment. Though we are young, we have executed several jobs such as various types of industrial silencers, ducts and structural works as sub vendor for various organizations which are up to the satisfaction of our clients. We have understood that by having every facility at our shop and the experience gathered we can enter directly into the manufacturing of industrial silencers, acoustic enclosures, acoustic rooms, ducts and all type of structural works. We have professional team for designing, engineering, marketing, documentation to ensure timely execution of jobs. We aim to be the leader in this segment by serving our esteemed clients promptly with at most satisfaction, you can rely on us in completing the jobs in time by our planned manner where our client will get day to day updating of the work status in a prescribed format by which our client can put their responsibilities on us. We request you to send your inspection personnel to inspect our shop to approve us in your vendor list. Extending our sincere co-operation, we remain with thanks. Truly Yours, Muralidharan.B Manager - Technical & Projects M-91+9003344932

COMPANY PROFILE - 4.imimg.com · Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: COMPANY PROFILE - 4.imimg.com · Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile

Dear Sir,

We are pleased to introduce ourselves that Himech Acoustics Engineering is situated in the engineering city,

Trichy, Tamilnadu, India.

Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly

effective planning standards.

Please find our profile in the attachment.

Though we are young, we have executed several jobs such as various types of industrial silencers, ducts and

structural works as sub vendor for various organizations which are up to the satisfaction of our clients.

We have understood that by having every facility at our shop and the experience gathered we can enter

directly into the manufacturing of industrial silencers, acoustic enclosures, acoustic rooms, ducts and all type

of structural works.

We have professional team for designing, engineering, marketing, documentation to ensure timely execution

of jobs.

We aim to be the leader in this segment by serving our esteemed clients promptly with at most satisfaction,

you can rely on us in completing the jobs in time by our planned manner where our client will get day to day

updating of the work status in a prescribed format by which our client can put their responsibilities on us.

We request you to send your inspection personnel to inspect our shop to approve us in your vendor list.

Extending our sincere co-operation, we remain with thanks.

Truly Yours,

Muralidharan.B

Manager - Technical & Projects

M-91+9003344932

Page 2: COMPANY PROFILE - 4.imimg.com · Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile

______________________________________________________________________________

Office Address : No : 12, Vasantha Nagar, 3rd

Cross, Viswas Nagar Extn., Karumandapam, Trichy - 620 001

Factory Address : No .686 / 4&5, Mookambigai Engineering College Opp.,Kalamavur Post, Pudukkottai - 622 502.

COMPANY PROFILE

HIMECH ACOUSTICS ENGINEERING

Page 3: COMPANY PROFILE - 4.imimg.com · Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile

COMPANY PROFILE

General Information

Firm : Hi-Mech Acoustics Engineering

Year of Establishment : 2011 (Hi-Mech Fabricators)

Registered office : No : 12, Vasantha Nagar, 3rd

Cross,

Viswas Nagar Extn.,

Karumandapam, Trichy.

Tamilnadu – 620 001

India.

Factory : Sr No .686 / 4&5,

Mookambigai Engineering College Opp.,

Kalamavur Post, Pudukkottai (Dt),

Tamilnadu – 622 502, India.

Contact Person : Mr.M.JESURAJ

Designation : Managing Director

Phone No : 00 91 431 2481970 (R) / +91-094434 25367

E-mail : [email protected], [email protected]

Website : www.himechgroup.com

Number of Employees : Administrative Staff – 11

Skilled worker - 18

SSI No. : 330221101542E - Part II

Nature of Business

Design, Engineering, Manufacture and Supply of safety valve & Vent Silencers

Design, Engineering, Manufacture and Supply of All type of Silencers

Nature of Jobs Executed : Reference List (Enclosed)

Nature of Customers : Sub Vendor List (Enclosed)

Certificates:

ISO – 9001-2008

Central Sales Tax

Import & Export License

Small Sale Industrial License

Micro, Small and Medium Enterprises

Banker Name : Indian Overseas Bank

Page 4: COMPANY PROFILE - 4.imimg.com · Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile

HIMECH ACOUSTICS ENGINEERING

Factory Total Area- 43,500 Sq.ft

Factory Shed Area: 2,600 Sq.ft

Page 5: COMPANY PROFILE - 4.imimg.com · Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile

Office Area: 750 Sq.ft

Rest & Power Room: 1,200 Sq.ft

Page 6: COMPANY PROFILE - 4.imimg.com · Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile

Uncovered Working Area: 38,950 sq.ft

Page 7: COMPANY PROFILE - 4.imimg.com · Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile

List of Machinery & Handling Facilities

Page 8: COMPANY PROFILE - 4.imimg.com · Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile

HIMECH ACOUSTICS ENGINEERING

LIST OF MACHINERY & HANDLING FACILITIES

Sl.No Descriotion &

Specification machines Make Capacity

No.of

Machines.

1 Welding machine Electro Engineers 0-400A 2

2 Welding machine SRI Ram 0-400A 2

3 Welding machine SRI Ram 0-250A 1

4 Welding machine TOSHON 0-200A 1

5 Welding machine Electro Engineers 0-200A 1

6 AG7 Grinding machine KPT 2

7 AG7 Grinding machine HITACHI 2

8 AG4 Grinding machine RALLI WOLF 1

9 Pencil (or) Die Grinding

machine RALLI WOLF

235V≈50Hz

550W/2.5A

Speed 27000 RPM

Collet size ø6mm

M15x1.0

1

10 Pipe Cutting machine BOSCH 220-230V / 50/60Hz

10A 1

11 PUG cutting machine ESAB - 1

12 Hand cutting set 4

13 Magnetic drilling machine KPT

Magnet (220/240V)

95W/12000N

(R.W:235V)

1

14 Magnetic drilling machine RALLI WOLF

Magnet (220/240V)

95W/12000N

(R.W:235V)

1

15 Radial drilling machine - 1

16 Small column drilling

machine - 1

17 Small (Bed & Column)

drilling machine - 1

18 DG (Genset) KIRLOSKAR 30 KVA 1

19 Flask Oven - 2

20 Box Oven

HP:3

Sl.No: 1014

Voltage : 220 / 250V

1

21 TIG set - 2

22 Air Compressor machine ELGI Equipment’s

limited 1

23 Flex Board with cable 3 Phase (3Ω)

24 Flex Board with cable 1 Phase

Page 9: COMPANY PROFILE - 4.imimg.com · Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile

ORGANISATION CHART

Page 10: COMPANY PROFILE - 4.imimg.com · Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile

OR

GA

NIS

AT

ION

CH

AR

T

Mr.

M.J

ES

UR

AJ.

, B

.E

Man

ager

Tec

hnic

al &

Pro

ject

Mr.

B.M

ura

lidhar

an.,

B.E

Mar

ket

ing S

taff

Ms.

E.P

riya.

, B

.E

Mar

ket

ing M

anag

er

Mr.

N.S

undar

., B

.E

Des

ign D

ept

CA

D D

esig

nin

g

Ms.

Kir

uth

iga.

, D

CE

Sto

res

Mr.

Aro

ckia

sam

y

Des

ign S

taff

bef

ore

ord

er

Ms.

B.

Bh

arat

hi.

, B

SC

Off

ice

Adm

in

Ms.

A.J

enif

er., B

.Com

.,

MB

A

Acc

ounts

Mr.

J.M

anuel

raj.

, M

.Co

m

Fit

ter

Mr.

S. A

rock

ia N

ath

an

Mr.

Ku

mar

esan

Mr.

Mu

ruges

an

Mr.

Sak

thiv

el

Pro

duct

ion /

QC

Dep

t

Mr.

Jayap

al.,

B.E

Mr.

Leo

Anan

d., B

.E

Purc

has

e D

ept

Mrs

. P

.Anja

li., D

CE

Adm

in S

taff

s

Mrs

. S

ophiy

a ., D

CE

Gri

nder

M

r. S

elvar

aj

Mr.

Vin

oth

Ku

mar

Mr.

Ch

inn

aiah

Mr.

Dh

anap

al

Mr.

Aji

th

Mr.

Pal

anis

amy

Wel

der

M

r.S

ivak

um

ar

Mr.

Ad

aikal

araj

Mr.

Ch

inn

ath

amb

i

Mr.

Ku

mar

Mr.

Sav

eriy

ar

Mr.

Sas

iku

mar

Mr.

Vee

ram

ani

Man

agin

g Pa

rtner

Page 11: COMPANY PROFILE - 4.imimg.com · Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile

JOBS EXECUTED BY HIMECH

Sl.No VENDOR NATURE OF JOB END CUSTOMER

1 P.R.ACOUSTICS MAIN STEAMLINE SV

SILENCER M/s. TECHNIP

2 P.R.ACOUSTICS

DRUM SV M/s. THYSSENKRUPP

INDUSTRIES INDIA PVT LTD

3 P.R.ACOUSTICS SUPER HEATER SV

SILENCER

M/s. THYSSENKRUPP

INDUSTRIES INDIA PVT LTD

4 P.R.ACOUSTICS STARTUP VENT

SILENCER

M/s. THYSSENKRUPP

INDUSTRIES INDIA PVT LTD

5 P.R.ACOUSTICS WARMUP VENT

SILENCER

M/s. THYSSENKRUPP

INDUSTRIES INDIA PVT LTD

6 P.R.ACOUSTICS MAIN STEAM STARTUP

SILENCER

M/s. EMAMI PARI MILLS

LTD

7 P.R.ACOUSTICS STEAM BLOWING LINE

SILENCER

M/s. EMAMI PARI MILLS

LTD

8 P.R.ACOUSTICS SRV 101 OUTLET LINE

SILENCER

M/s. EMAMI PARI MILLS

LTD

9 P.R.ACOUSTICS SRV 102 OUTLET LINE

SILENCER

M/s. EMAMI PARI MILLS

LTD

10 P.R.ACOUSTICS SAFETY VALVE

SILENCER

M/s. FORBES COMPANY

LIMITED

11 P.R.ACOUSTICS STARTUP VENT VALVE

OUTLET SILENCER M/s. CETHAR LIMITED

12 P.R.ACOUSTICS DRUM SAFETY VALVE

OUTLET SILENCER M/s. CETHAR LIMITED

13 P.R.ACOUSTICS WARMUP VENT

SILENCER M/s. CETHAR LIMITED

14 P.R.ACOUSTICS BFW TURBINE OUTLINE

SILENCER

M/s. ISGEC HEAVY

ENGINEERING LTD

15 P.R.ACOUSTICS DM PUMP TURBINE

OUTLINE SILENCER

M/s. ISGEC HEAVY

ENGINEERING LTD

16 P.R.ACOUSTICS FD FAN TURBINE

OUTLINE SILENCER

M/s. ISGEC HEAVY

ENGINEERING LTD

17 P.R.ACOUSTICS HHP DRUM SAFETY

VALVE SILENCER M/s. THERMAX LIMITED

18 P.R.ACOUSTICS HHP SHSV SILENCER M/s. THERMAX LIMITED

19 PK ENGINEERING VENT SILENCER M/s. UTTAM ENERGY

20 APEX HAND RAILS M/s. BHEL

21 APEX ELBOW DUCT M/s. BHEL

22 APEX D DUCT M/s. BHEL

23 APEX HOPPER DUCT M/s. BHEL

24 APEX ECO DUCT M/s. BHEL

25 APEX CONVEYER GALLERY M/s. NMDC – BHEL

26 APEX T-DUCT M/s. BHEL

27 APEX ECO TRUSS M/s. BHEL

Page 12: COMPANY PROFILE - 4.imimg.com · Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile

PRODUCT

Page 13: COMPANY PROFILE - 4.imimg.com · Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile

START UP VENT SILENCER

We are offering start up vent silencer made from high quality raw material.

These start up vent silencers are produced in compliance of the rules and lodes

followed in the industry as per the specification. Our vent silencers are used to

control the harmful and environmentally unacceptable high frequency noise while

venting the highly pressurized air, nitrogen, natural gas and other hydrocarbon

gases into the atmosphere during the production process in industries.

Procedure for sizing vent silencers

Hi-Mech Acoustics silencers, can size any gas or steam vent application

when provided the following data.

Vent media (Steam or type of gas)

Mass flow (Preferably in pounds per hour or kg per hour)

Temperature and pressure of upstream of the control or relief valve

Line connection to the vent silencer

Silenced noise level requirements

Page 14: COMPANY PROFILE - 4.imimg.com · Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile

SAFETY VALVE SILENCER

Every industry makes use of safety valves to protect systems against over

pressure when these safety valves are opened to vent steam, gas or vapor it is often

accompanied by excessive noise levels. Noise level as high as 150 to 160 dB (A)

are not audible/unacceptable. It will affect the hearing level of employees and

complaints may also be received from surrounding residential areas or factories.

Hi-Mech Acoustics safety valve silencer will reduce such noise to environmentally

acceptable levels. [Such as 85dB (A)] as specified by Indian pollution control

boards.

The following process values are required to make the appropriate selection.

Medium

Capacity

Medium temperature

Pressure before the valve and after the valve

Sound level required

Connection size

Page 15: COMPANY PROFILE - 4.imimg.com · Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile

BLOW OFF SILENCER

Blow off silencer is a type of vent silencer. The blow down of highly

compressed vapor or gas into the open air sets kinetic energy free in the form of

high amplitude pressure fluctuations. The result is an extremely high sound

pressure level which must be reduced. Such emission can be very effectively be

limited with blow-off silencers.

For the design of the silencer the following information is needed

Type of fluid (Gas or Steam)

Temperature and Pressure upstream (before) valve

Permissible sound pressure level at immission point (in defined

distance) E.g: 85 dB(A) in 1m distance

Diameter of inlet nozzle

Page 16: COMPANY PROFILE - 4.imimg.com · Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile

DISCHARGE SILENCER

The discharge silencer is used to reduce the discharge noise of the

compressor / blower when discharging fluid into process. It is constructed in

circular shape. The fluid passes through the annular acoustic packing where the

sound energy is absorbed. The straight flow path through annular acoustic cylinder

ensures minimum pressure drop.

The following data are required to design discharge silencer.

Flow rate

Temperature

Inlet size

Allowable pressure drop

Silenced noise level requirements

Page 17: COMPANY PROFILE - 4.imimg.com · Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile

SUCTION SILENCER

The suction silencer is used to reduce the suction noise of the compressor/

blower. It is constructed in circular shape. The fluid passes through the annular

space of the acoustic packing where the sound energy is absorbed. The straight

flow path through annular acoustic cylinder ensures minimum pressure drop.

The following data are required to design suction silencer.

Flow rate

Temperature

Inlet size

Allowable pressure drop

Silenced noise level requirements

Page 18: COMPANY PROFILE - 4.imimg.com · Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile

FAN SILENCER

The fan silencer is used to reduce the suction and discharge noise of the fan.

It is an absorptive type silencer and is very effective for high frequency noise

attenuation. Consequently fan silencers shall be supplied in rectangular shape. The

internal of fan silencer is constructed with series of rectangular baffle with

aerodynamic design to offer minimum pressure drop.

The following data are required to design fan silencer.

Application

Flow rate

Temperature

Fan inlet / outlet size (Depending on application)

Allowable pressure drop

Silenced noise level requirements

Page 19: COMPANY PROFILE - 4.imimg.com · Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile

EXHAUST SILENCER

The exhaust silencer is used to reduce the exhaust noise of the engine and

turbine. The engine silencer is a combination of absorptive and reactive type

silencer to attenuate high and low frequency noise. The gas turbine exhaust

silencer will be absorptive type silencer. The exhaust silencer will be similar to that

of vent silencer. It is generally offered in circular shape.

For the design of the exhaust silencer the following information are needed

Type of Fluid (Gas (or) Steam)

Mass flow (Preferable in pounds per hour or kg per hour)

Temperature and pressure upstream of the control or relief valve

Line connection to the vent silencer

Silenced noise level requirements

Page 20: COMPANY PROFILE - 4.imimg.com · Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile

ACOUSTIC ENCLOSURE

We are offering Industrial enclosure can reduce reverberation and reflected

noise in industrial environments. Our design will take into consideration of

verifications, access openings, doors and vision panels. We provide simple and

cost effective solutions which are suitable for a variety of industrial applications.

Enclosures use the modular system. The modular acoustic panels can be

dismantled and re-assembled to another location without affecting the acoustic

performance.

Typical Acoustic Enclosure:

Compressor enclosures

Diesel and gas generator enclosures

Acoustic enclosures for fans / blowers

Acoustic enclosures for boiler feed pump.

Page 21: COMPANY PROFILE - 4.imimg.com · Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile

GENERAL FABICATION WORK PHOTO GALARY

Page 22: COMPANY PROFILE - 4.imimg.com · Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile

COLUMN

D-DUCT

Page 23: COMPANY PROFILE - 4.imimg.com · Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile

DUCT

ECO DUCT

Page 24: COMPANY PROFILE - 4.imimg.com · Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile

SADDLE SUPPORT

HOPPER DUCT

Page 25: COMPANY PROFILE - 4.imimg.com · Ours is an ISO certified organization, we are adopting ASME, OHSA standards and maintaining highly effective planning standards. Please find our profile

SILENCER PHOTOS