SUMMARY DAILY ACTIVITY REPORT
TUBULAR INSPECTION AT WAYANG WINDU GEOTHERMAL STAR ENERGY
AS JANUARY THRU MAY, 2014
ITEMDATE
KIMAP DESCRIPTION QYTQTY ACCEPTED REJECTED TOTAL
OF INSPECTION INSPECT / USABLE BOX PIN BOTH BODY REJECTED
1 3-5 JAN 2014 54252545 CASING 4-2 TESTING REPORT 10 10 10 - - - - -
TOTAL
Prepared By,
Mr. ARDI GINTING Japs
PTLM - INSPECTOR (S)
SUMMARY DAILY ACTIVITY REPORT
TUBULAR INSPECTION AT WAYANG WINDU GEOTHERMAL STAR ENERGY
AS JANUARY THRU MAY, 2014
DETAIL REJECTED TYPE OF
REMARKSINSPECTION
CASING 4-2 TESTING REPORT MAINTENANCE COMPLETED
ACKNOWLADGE CUSTOMER REPRESENTATIVE
SE WAREHOUSE SUPERVISOR
Customer : STAR ENERGY GEOTHERMAL (WW) Services Receipt No. : 007 / LM-SEWW-JKT/V-2014
Order No. : 4200001182 - 05 D a t e : May 05, 2014
Ordered by : Mr. Ardi Ginting Inspection Location : SE WAREHOUSE, PENGALENGAN
INSPECTION REPORT of NEW TUBULAR GOODS
TYPE OF INSPECTION : n Visual Body Inspection (VBI)
n VISUAL THREAD INSPECTION (VTI)
n API Full Length Drifting
n Internal / External Cleaning
n Ultrasonic Wall Thickness Spot Check
n Internal / External Coating
n Expose Thread Protection with EON 300
n Tally Length
603 Jts 9 5/8' OD CASING PERFORATED R3 CITRA TUBINDO
Length Size Type Range Manufacturer
47 PPF 11.99 mm K-55 BC SEAMLESS
Weight Wall Grade Connections
Note : This pipe was inspected for surface Imperfection to conform with :
Customer Specification Appropriate dimension per API Standart :
12.5 % of the specified wallthickness for this pipe is :
87.5 % of the specified wallthickness for this pipe is :
Drift Diameter ??? Drift Length :
SUMMARY RESULT :
??? Length were found to be free of defects exceeding 12.5 % of the specified wall thickness and comply with above drift specification, where applicable.
[ Identified by white paint band and PT. Lekom Maras inspected stenciled in white on the pipe body near the coupling or box end ].
Footage :
??? Length were found to be free of defects exceeding 12.5 % of the specified wall thickness but have defective pins and / or coupling.
[ Identified with a white paint on the pipe body near the coupling or box end and a red paint band around the defective connection ].
??? Pins ??? Coupling ??? Both Pin & Coupling found defective. Footage :
??? Lengths were found to defects exceeding 12.5 % od the specified wall thickness.
[ Identified by a red paint band and PT. Lekom Maras inspected stenciled in white on the pipe body near the coupling or box end ]Footage :
??? Lenghts were found to have decefts exceeding 12.5 % of specified wall thickness and have defective pins and / or couplings.
[Identified with a red paint band on the pipe body near the coupling/box end & a red paint band around the defective connection]
??? Pins ??? Coupling ??? Both Pin & Coupling found defective. Footage :
??? Lenghts were found would not pass an API drift [ Identified by a red paint ].
??? Jts TOTAL INSPECTED
COMMENTS : FROM 603 Jts INSPECTED, 16 Jts REJECTED CONNECTION AND 587 Jts IN GOOD CONDITION
Welded / Seamless
Mr. Ardi Ginting < Japurut >
ACKNOWLEDGE CUSTOMER REPRESENTATIVE PTLM - INSPECTOR (s)
TSD.FM.QMS.010.00
007 / LM-SEWW-JKT/V-2014
May 05, 2014
SE WAREHOUSE, PENGALENGAN
INSPECTION REPORT of NEW TUBULAR GOODS
CITRA TUBINDO
Manufacturer
SEAMLESS
Appropriate dimension per API Standart : ???12.5 % of the specified wallthickness for this pipe is : ???87.5 % of the specified wallthickness for this pipe is : ???
Drift Length : ???
Length were found to be free of defects exceeding 12.5 % of the specified wall thickness and comply with above drift specification, where applicable.
[ Identified by white paint band and PT. Lekom Maras inspected stenciled in white on the pipe body near the coupling or box end ].
??? Ft
Length were found to be free of defects exceeding 12.5 % of the specified wall thickness but have defective pins and / or coupling.
[ Identified with a white paint on the pipe body near the coupling or box end and a red paint band around the defective connection ].
??? Ft
Lengths were found to defects exceeding 12.5 % od the specified wall thickness.
[ Identified by a red paint band and PT. Lekom Maras inspected stenciled in white on the pipe body near the coupling or box end ]
??? Ft
Lenghts were found to have decefts exceeding 12.5 % of specified wall thickness and have defective pins and / or couplings.
[Identified with a red paint band on the pipe body near the coupling/box end & a red paint band around the defective connection]
??? Ft
Lenghts were found would not pass an API drift [ Identified by a red paint ].
TOTAL INSPECTED
FROM 603 Jts INSPECTED, 16 Jts REJECTED CONNECTION AND 587 Jts IN GOOD CONDITION
Welded / Seamless
Mr. Ardi Ginting < Japurut >
PTLM - INSPECTOR (s)
TSD.FM.QMS.010.00
TIME - SHEET
Name : Mr. Ardi Ginting < Japurut > CustomerPosition : Inspector < ASNT Level II > Contract No.Month : Feb 01, 2014 Thru Feb 28, 2014 Location
Type of Services : VISUAL BODY INSPECTION (VBI), VISUAL THREAD INSPECTION (VTI)
API FULL LENGTH DRIFT (FLD), ULTRASONIC WALL THICKNESS SPOT CHECK (UT),
INTERNAL/EXTERNAL CLEANIN, INTERNAL / EXTERNAL COATING, EXPOSED THREAD WITH EON FILM 300
DATE DESCRIPTION MANDAY REMARKS
MARCH
1 STARTED INSPECTION CASING 9-5/8" 47 PPF 0.472" WT L-80 AB TC R-3 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
31 TOTAL MAN DAYS 31 31
TIME - SHEET
: STAR ENERGY
: 4200001182-OS
: PANGALENGAN / WW
VISUAL BODY INSPECTION (VBI), VISUAL THREAD INSPECTION (VTI)
API FULL LENGTH DRIFT (FLD), ULTRASONIC WALL THICKNESS SPOT CHECK (UT),
INTERNAL/EXTERNAL CLEANIN, INTERNAL / EXTERNAL COATING, EXPOSED THREAD WITH EON FILM 300
SUBMITTED BY
Mr. Ardi Ginting Japs
REVIEWED BY
Mr. DJOKOWI'ng
PTLM REPRESENTATIVE
APPROVED BY
COMPANY REPRESENTATIVE
NOTE :
Custumer : STAR ENERGY GEOTHERMAL (WW) Service Receipt No. : 008/LM-SEWW-JKT/III-2014
Order No. : 4200001182-OS D a t e : March 22,2014
Ordered By : Mr. Ardi Ginting < Japs > Inspection Location : SE WAREHOUSE, PENGALENGAN
SERVICED : INTERNAL CLEANING
PERFORMD EXTERNAL CLEANING
INTERNAL COATING WITH EON 240
EXTERNAL COATING WITH EON 450
STORAGE COMPOUND WITH EON FILM 300
SPECIFICATION : API 5 CT
MATERIAL : CASING 7" 26 PPF 0.362" WT K-55 BC R3 SCC
INSPECTED : KIMAP 408030901
(SERVICED)
SUMMARY REPORT
64 Jts WERE UNIFORMLY INTERNAL / EXTERNAL CLEANING ACCEPTABLE CONDITION
PRIOR TO APPLICATION.
64 Jts WERE UNIFORMLY EXTERNAL COATED WITH EON 450.
64 Jts WERE UNIFORMLY INTERNAL COATED WITH EON 240. ALL EXCESS COATING WAS
FLOWED OUT.
64 Jts THE ABOVE MENTION WERE PROCTECED WITH EON FILM 300 ON THE THREDS
RESULT
55 Jts ACCEPTED
9 Jts REJECTED CONDITION
64 Jts TOTAL SERVICED
Mr. Ardi Ginting <Japs>
PTLM - INSPECTOR (s)
TSD.FM.QMS.010.00 (2)
008/LM-SEWW-JKT/III-2014
March 22,2014
SE WAREHOUSE, PENGALENGAN
SUMMARY REPORTWERE UNIFORMLY INTERNAL / EXTERNAL CLEANING ACCEPTABLE CONDITION
PRIOR TO APPLICATION.
WERE UNIFORMLY EXTERNAL COATED WITH EON 450.
WERE UNIFORMLY INTERNAL COATED WITH EON 240. ALL EXCESS COATING WAS
FLOWED OUT.
THE ABOVE MENTION WERE PROCTECED WITH EON FILM 300 ON THE THREDS
ACCEPTED
REJECTED CONDITION
TOTAL SERVICED
Mr. Ardi Ginting <Japs>
PTLM - INSPECTOR (s)
NEW / USED TUBING
INSPECTION TALLY SHEET
CUSTOMER : STAR ENERGY WAYANG SINDU W.O No. : 4200001182-OS
PIPE : CSG O.D : 9-5/8" WEIGHT : 47 PPF WALL : 11.99 MM GRADE : L-80 CONN. : AB TC MANUFACTUR : CITRA TUBINDO
LENGTH VISUAL THREAD CONDITION API FULL VISUAL BODY INSPECTION
NO. INSPECTION BOX PIN LENGTH DRIFT Incl. UT. SPOT CHECK
126 SVC SVC PASSED RWT 11.7 MM
127 SVC SVC PASSED RWT 11.9 MM
128 SVC SVC PASSED RWT 11.8 MM
129 SVC SVC PASSED RWT 11.6 MM
130 SVC SVC PASSED RWT 11.6 MM
131 SVC SVC PASSED RWT 11.9 MM
132 SVC PT PASSED RWT 11.7 MM
133 SVC SVC PASSED RWT 11.8 MM
134 SVC SVC PASSED RWT 11.8 MM
135 SVC SVC PASSED RWT 11.9 MM
136 SVC SVC PASSED RWT 11.9 MM
137 SVC SVC PASSED RWT 11.8 MM
138 SVC SVC PASSED RWT 11.9 MM
139 SVC SVC PASSED RWT 11.9 MM
140 SVC SVC PASSED RWT 11.9 MM
141 SVC SVC PASSED RWT 11.6 MM
142 SVC SVC PASSED RWT 11.8 MM
143 SVC SVC PASSED RWT 11.8 MM
144 SVC SVC PASSED RWT 11.9 MM
145 SVC SVC PASSED RWT 11.9 MM
146 SVC SVC PASSED RWT 11.9 MM
147 SVC SVC PASSED RWT 11.8 MM
148 SVC SVC PASSED RWT 11.8 MM
149 SVC SVC PASSED RWT 11.9 MM
150 SVC SVC PASSED RWT 11.9 MM
REMARKS : 1 Joint Rejected Connection
TOTAL ACCEPTED FOOTAGE : 1084.60 FT TOTAL REJECTED FOOTAGE :
ABBRECIATIONS :CT - CORRODED THREAD CO - CUT OFF SD -
TD - THREAD DAMAGED WO - WASHED OUT GT -
M - MASHED SVC - SERVICEABLE
Mr/ Ardi Ginting < Japs >
NEW /
PTLM - Inspector (s)
TSD-FM/QMS.012.00.1 (6)
NEW / USED TUBING
INSPECTION TALLY SHEET
DATE : 15-Feb-14
COLOR LENGTH
CODE TALLY (FT)
WHITE 45.40
WHITE 45.40
WHITE 45.40
WHITE 45.40
WHITE 45.40
WHITE 45.40
WHITE 45.40
WHITE 45.40
WHITE 45.40
WHITE 45.35
WHITE 44.85
WHITE 44.86
WHITE 44.87
WHITE 44.88
WHITE 44.89
WHITE 44.90
WHITE 44.91
WHITE 44.92
WHITE 44.93
WHITE 44.94
WHITE 44.95
WHITE 44.96
WHITE 44.97
WHITE 44.98
WHITE 44.99
1 Joint Rejected Connection
TOTAL REJECTED FOOTAGE : 45.50 FT
SEAL DAMAGE
GALLING THREAD
Mr/ Ardi Ginting < Japs >
NEW / USED CASING
PTLM - Inspector (s)
INSPECTION AND MAINTENANCE OF OILFIELD COUNTRY TUBULAR GOODS
TUBULAR SERVICES DIVISION
Jl. TB. Simatupang Kav. 20
Jakarta 12560 - INDONESIA
BERITA ACARA INSPEKSI
Pada hari ini, 17 Maret 2014 telah dilakukan inspeksi Casing milik Star Energy Geothermal (WW),Dengan data sebagai berikut :
Nama Barang : Casing 4-1 / 2" 11.60 PPD J-55 BC R-2
Jumlah : 1 Joints
Tempat : Pengalengan Wayang Windu
Waktu : Senin, 17 Maret 2014 - Jam 15.25 s/d 15.40 Wib
Jenis Inspeksi : Visual Body Inspection (VBI) & API Full Length Drifted
Inspektor dari PT. LEKOM MARAS telah melakukan verifikasi dan inspeksi terhadap 1 joint Casing
Sesuai dengan permintaan diatas.
Setelah dilakukan verifikasi inspeksi dan Drifting ditemukan sebagai berikut :
1 . Casing 4-1/2" 11.66 PPD J-55 BC R-2 1 Jts Bent/Bengkok
Ini terjadi pada saat penyusunan Pipa dan pada saat manuver ban belakang Forklift mengenai Box
/ Coupling dari Pipa tersebut.
Demikian berita acara inspeksi Casing ini dibuat dengan sebenarnya.
Pengalengan, 17 Maret 2014
INSPEKTOR PIHAK III MengetahuiPT. Lekom Maras Star Energy Geothermal (WW)
Ardi Ginting < Japs > Amir Mukmini Inspection Operator SE Reps
Gedung Ratu Prabu 2nd Floor
< Gambar terlampir >
INSPECTION AND MAINTENANCE OF OILFIELD COUNTRY TUBULAR GOODS
Telp : (62-21) 788-46221
Fax : (62-21) 788-46219
BERITA ACARA INSPEKSI
Pada hari ini, 17 Maret 2014 telah dilakukan inspeksi Casing milik Star Energy Geothermal (WW),Dengan data sebagai berikut :
Casing 4-1 / 2" 11.60 PPD J-55 BC R-2
1 Joints
Pengalengan Wayang Windu
Senin, 17 Maret 2014 - Jam 15.25 s/d 15.40 Wib
Visual Body Inspection (VBI) & API Full Length Drifted
Inspektor dari PT. LEKOM MARAS telah melakukan verifikasi dan inspeksi terhadap 1 joint Casing
Sesuai dengan permintaan diatas.
Setelah dilakukan verifikasi inspeksi dan Drifting ditemukan sebagai berikut :
1 . Casing 4-1/2" 11.66 PPD J-55 BC R-2 1 Jts Bent/Bengkok
Ini terjadi pada saat penyusunan Pipa dan pada saat manuver ban belakang Forklift mengenai Box
/ Coupling dari Pipa tersebut.
Demikian berita acara inspeksi Casing ini dibuat dengan sebenarnya.
Pengalengan, 17 Maret 2014
MengetahuiStar Energy Geothermal (WW)
Amir Mukmini
DAILY PROGRESS REPORT
CUSTOMER : STAR ENERGY DATE
ITEM NO. : 07 / Cm - SE/IV/14 LOCATION
REPORT NO. : 8 WEATHER
MATERIAL INSPECT : Casing 9 5/8" 47 PPF K-35 BC R-3 PERFORATED
SCOPE OF WORK : Visual Thread Inspection / VTI
KIMAP : 408031031
VBI VTI FLD EMI UTCLEAN CLEAN COAT COAT
DOPEI.D O.D I.D O.D
- - - - - - - - - -
Remarks :
TOTAL UP TO DATE
TYPE OF INSPECTION QTY OK REJECT REMAININGPERCENTAGE
REMARKPROCESS
VISUAL BODY INSPECTION (VBI)
API FULL LENGTH DRIFT (FLD)
ULTRASONIC WALL THICKNESS (UT)
EXTERNAL CLEANING BY GRINDER
INTERNAL CLEANING BY RATLING
EXTERNAL COATING
INTERNAL COATING
DOPE / COMPOUND THREAD
TALLY LENGTH
VISUAL THREAD INSPECTION (VTI)
REJECT
BOX PIN BOX S PIN ND
TOTAL JOINT COMPLETED
PERCENTAGE (%)
PREPARED BY
Daily
TOTAL INSPECT
ARDI GINTA GINTING
DAILY PROGRESS REPORT
: 15/04/2014
: PENGALENGAN
: GOOD
Casing 9 5/8" 47 PPF K-35 BC R-3 PERFORATED
Visual Thread Inspection / VTI
408031031
DOPE TALLY
- -
TOTAL UP TO DATE
REMARK
REJECTTOTAL % VTI
ND
::