19
House Floor plans Framing plans Heating Forced warm air Plans: Elevations Site plan System: Baseboard Radiant 1. 2. 3. 4. Ventilation Strategy: Distribution Strategy: Basic System Type: Method of Dealing with Pressure Imbalances: Control System: Special Customer Requirements: Ventilation Equipment: 1. 2. 3. 4. 5. Other Exhaust Appliances: (list) 1. 2. 3. 4. Prepared By: HRAI #: Job Name: Signature: Date: Job #: Official Use: W0 Combustion Appliances CONCEPTUAL DESIGN PLAN - REQUIRED INFORMATION CHECKLIST Draft Type Exhaust only (worksheet W1A) Balancedcombined with forced air (worksheet W1B) Balanceddirect ducted (worksheet W1C) © Copyright HRAI Residential Ventilation WORKSHEET W0 r 08/10

Complete Ventilation Design Summary Pack

Embed Size (px)

DESCRIPTION

Complete Ventilation Design Summary

Citation preview

House Floorplans Framingplans Heating ForcedwarmairPlans: Elevations Siteplan System: Baseboard Radiant1.2.3.4.VentilationStrategy:DistributionStrategy:BasicSystemType:MethodofDealingwithPressureImbalances:ControlSystem:SpecialCustomerRequirements:VentilationEquipment:1.2.3.4.5.OtherExhaustAppliances:(list)1.2.3.4.Prepared By: HRAI #: J ob Name:Signature: Date: J ob #: Official Use:W0CombustionAppliancesCONCEPTUAL DESIGN PLAN - REQUIRED INFORMATION CHECKLISTDraftTypeExhaustonly(worksheetW1A)Balancedcombinedwithforcedair (worksheetW1B)Balanceddirectducted(worksheetW1C)CopyrightHRAIResidentialVentilationWORKSHEETW0r08/10 W1AFEATURESCentralorlocalexhaustfansMakeupairbyinfiltration Forcedwarmairheatingsystem?orNO Smallcapacityrecirculationsystem?YESNONO= required, X =notrequired Ventilationcapacity W2Exhaust requirements W 2ExhaustOnlySystemDETAILEDDESIGNPLANSpillageSusceptibleYESDETAILEDDESIGNTASKS:Mayrequiremakeupairsysteminterlockedtoventilationsystemand/orexhaustappliancescombustionappliance(s)?CAUTIONWillnotmeetventilationdistributionrequirementsSTOPVentilation RecordHeatrecoveryrequired?UsebalancedheatrecoverysystemUseworksheetW1BorW1CProceedwithdetaileddesignSTOPworksheet#VentilationRecordYES Exhaustrequirements W2Systemlayout,recirculationsystem(forcedwarmairorsmallcapacityrecirculation)planImbalanceatTVCC(exhaustlargerthansupply)orfieldtest W3AImbalanceatCEC(onlyifspillagesusceptibleappliances)orfieldtest W3CCheckmixedairtemperatureandpreheatersize(makeupairconnectedtoforcedair)W4BSystemlayout,grillesize,doorundercuts(centralexhaustfan)plan+ W5Selectfanandsizeducts(singleductfans,rangehoods,bathfansetc.,ifrequired)W6ASelectfanandsizeducts(centralfanifrequired)W6BSelectfanandsizeducts(smallcapacityrecirculationsystem,ifrequired)W6BSizepoweredairintake/makeupairduct(ifrequired)W6CSizefurnaceoutsideairduct(ifrequired)W6DSizepassivemakeupairduct(ifrequired)W6E Describecontrolstrategy W7OtherOtherPrepared By: HRAI #: J ob Name:Signature: Date: J ob #: Official Use:VentilationRecordYESCopyrightHRAIResidentialVentilationWORKSHEETW1Ar08/10 W1BFeaturesVentilationsupplyairconnectedtoreturnductofforcedairDedicatedexhaustductingor"simplifiedconnection"NONOProceedwithdetaileddesign= required, X =not required DETAILEDDESIGNTASKS: W2 W2worksheet #ExhaustrequirementsVentilationRecord VentilationcapacityVentilationRecordDETAILEDDESIGNPLANSpillageSusceptiblecombustionappliance(s)?Ventilationsupplyconnectedtoforcedairwithoutheatrecovery?CAUTIONIntakeairheatermayberequired.CheckforcedairsystemmixedairYEStemperature&heatercapacityCAUTIONMayrequiremakeupairsysteminterlockedtoexhaustappliance(s)BalancedSystem,CombinedwithForcedAirHRV/ERVbasedsystem?YESSystemlayout,recirculationsystem(forcedwarmair)plan W3C AdjustHRV/ERVairflow W4ACheckmixedairtemperature,preheatersize(intakeorHRV/ERVconnectedtoforcedair)W4BCheckdeliveredairtemperature,selectintakeairheater(ifrequired)W4C plan+ W5Selectfanandsizeducts(singleductfans,rangehoods,bathfansetc.,ifrequired)W6ASelectfanandsizeducts(HRV/ERVorcentralfanifrequired)W6BSizepoweredairintakeduct(ifrequired) W6CSizefurnaceoutsideairintakeduct(ifrequired)W6DSizepassivemakeupairduct(ifrequired W6EDescribecontrolstrategy W7Prepared By: HRAI #: J ob Name:Signature: Date: J ob #: Official Use:OtherSystemlayout,grillesize,doorundercuts(HRV/ERVorcentralfan)ImbalanceatCEC(onlyifspillagesusceptibleappliances) orFieldTestHRV/ERVbasedsystem?YESCopyrightHRAIResidentialVentilationWORKSHEETW1Br08/10 W1CFeaturesHRV/ERVorexhaust+intakefanandheaterDirectsupplyorexhaustfromallhabitableroomsNOYES YesCautionSpillageSusceptible Mayrequiremakeupairsystemcombustionappliance(s)? interlockedtoexhaustappliance(s)NOProceedwithdetaileddesign= required, X =not required DETAILEDDESIGNTASKS: Ventilationcapacity W2 Exhaustrequirements W2VentilationRecordVentilationRecordDETAILEDDESIGNPLANBalancedSystem,DirectDuctedworksheet #HRV/ERVbasedsystem?YESExhaustsystemwithintakefanandheater?Checkairdeliveryarrangement(highorlowwall)againstheatercapacityCheckairdelivery arrangement(highorlowwall)againstHRV/ERVeffectiveness Exhaustrequirements W 2ImbalanceatCEC(onlyifspillagesusceptibleappliances)W3CAdjustHRV/ERVairflow(ifrequired)W4ACheckdeliveredairtemperature/selectintakeairheater(ifrequired)W4CSystemlayout,grillesize,doorundercuts(centralfanorHRV/ERV)plan+ W5Selectfanandsizeducts(Singleductfans,rangehoods,bathfansetc.,ifrequired) W6ASelectfanandsizeducts(centralfan/HRV/E W6BSizepoweredairintakeduct(ifrequired) W6CSizepassiveairintake(ifrequired) W6E Describecontrolstrategy W7OtherOtherPrepared By: HRAI #: J ob Name:Signature: Date: J ob #: Official Use:VentilationRecordHRV/ERVbasedsystem?YESExhaustsystemwithintakefanandheater?Checkairdeliveryarrangement(highorlowwall)againstheatercapacityCheckairdelivery arrangement(highorlowwall)againstHRV/ERVeffectivenessCopyrightHRAIResidentialVentilationWORKSHEETW1Cr08/10 A H Oil Other SolidFuel(includingFireplaces) I DirectVent(sealedcombustion) PositiveVentingInducedDraft P.C.EmailAddress:B ClothesDryer(s) J DowndraftCookTop Other(exhaust) P.C. NoC @20 cfm EmailAddress:@10 cfm@10 cfm CSAF326M91@10 cfm R2000Signature: Date: ControlsFunctioning KD FiltersClean@ 60 = cfm DampersAccessible@ 20 = cfm Drainloopandconnectioncfm@ 100 = cfm @ 50 = cfmcfmE LF MG 1 cfm P.C. TVC HVI2 cfm EmailAddress: TVC HVI3 cfm TVC HVI R20004 cfm TVC HVIPrepared By: HRAI #: J ob Name:Signature: Date: J ob #: Official Use:Date: Manufacturer/Model: Location: Signature:(exhaust)EQUIPMENTLocation: %SensibleEfficiency@25C ADDITIONALManufacturer/Model:Location: SonesIcertifythisventilationsysteminstalltobeinaccordancewith: Manufacturer/Model:CSAF326M91 Location: SonesManufacturer/Model: TVCManufacturer/Model: HVIrated cfmHigh DesignAirflow cfmhigh cfmlowHRV/ERV %SensibleEfficiency@0C wattsSonesPhone:Sones cfmHigh cfmLowMEASUREDFax: Address:City: TVCSYSTEMS cfmLowContinuousMinimumContinuousExhaustInsulatedductssealedSYSTEMLocation: TVCsystemEXHAUSTairflowmeasuredwatts Name: HRAI#: HRV/ERVTVCsystemSUPPLYairflowmeasuredEXHAUSTCAPACITYKitchen(s) cfm Labelsupply/exhausthood Bathroom(s)Total Forcedairsystem Continuousmode InterlockedKitchenintakegreasefilter Kitchenexh.40"torangeIntermittentMinimumIntermittentExhaustTotal TOTALVENTILATIONOtherBedrooms cfm Icertifythisventilationsystemdesigntobeinaccordancewith:Bathrooms&Kitchens cfm cfmTotalVentilationCapacity(TVC) cfmFansoperatingandclean CAPACITY(TVC)Bsmt&MasterBedroom EXHAUST(220cfmdefault) Address:(over150cfm) City: Depressurizationtest/Calc.Required? Fax: EQUIPMENT(150cfmdefault) Name: HRAI#: Yes Phone:cfmOtherHab.RoomsINSTALLATIONCHECKLISTExhaust4"abovegrade Supply18"abovegrade Kitchen(s) cfm Supplyintake6'fromexhaust(recommended) Bathroom(s)Other#DESIGNERFlowmeasuringstations cfm Supplyintake3'fromotherexhaust cfm Distributiontoallhabitablerooms(nonforcedair)HouseID#: BUILDER NoDepLimit Address:LowestDepressurizationLimit_________Pa.Pascalslimit City: NaturalDraftorBVentAtmospheric 5padepresslimit Phone: Fax:INSTALLERRESIDENTIALMECHANICALVENTILATIONRECORDForCertificationofDesignandPerformanceofResidentialVentilationSystems W2COMBUSTIONAPPLIANCESForcedAir NonForcedair Roll#: Permit#:LOCATIONHEATINGSYSTEM/Electric Gas Lot&Plan: NoCombustionAppliances NoDepressurizationlimit Civicaddress: 5paDepresslimit Name:CopyrightHRAIResidentialVentilationWORKSHEETW2r08/10 W3Aline#1.FLOORAREA ft2 301(totalheatedfloorareaincludingbasement;countcrawlspaceat1/2actualarea) HouseACH50 3023.COMBUSTIONAPPLIANCEDEPRESSURIZATIONLIMITpa 303 3044.ALLOWABLENETEXHAUST 305cfm5.ACTUALNETEXHAUST cfm 306minus cfm 307 =equals cfm 308TotalFloorAreaIMBALANCE@TVCC(TotalVentilationCapacityCondition)TVCCExhaustAllowableNetExhaust@TVCCFlowFactorFloorArea(301)________ft2xACH50(302)________xFlowFactor(304)________=2.ASSUMEDAIRCHANGESPERHOURAT50PASCAL'SIfspillagesusceptible,=5pa.Ifnonspillagesusceptible,=10paforsystemswithmoreexhaustthansupply@TVCCflowfactor=0.037flowfactor=0.022 DepressurizationLimit@[email protected] TypicalR20001.0ACH Prairies/North(new)1.0 ACHAtlantic(new)1.5 ACH Otherprovinces(new)1.4 ACHOlderhomes2.5 ACHoractualtest_________Note:Ifsupplyisgreaterthanexhaust,useworksheet#W3B6.REQUIREDMAKEUPAIRFLOW cfmminus cfm=equalscfm309pa7.DESCRIPTIONOFMAKEUPAIRSYSTEM8.ONSITETESTDEPRESSURIZATIONTEST Required NotRequired 310Prepared By: HRAI #:Signature: Date: Official Use:J ob Name:J ob #:ActualNetExhaust@TVCC(line308)RequiredMakeUpAirflow@TVCCAtDepressurizationLimit(line303)AllowableNetExhaust@TVCC(line305)Note:IfActual NetExhaustislessthan AllowableNetExhaustnoactionisrequired.TightR20000.5ACH TypicalR20001.0ACH Prairies/North(new)1.0 ACHAtlantic(new)1.5 ACH Otherprovinces(new)1.4 ACHOlderhomes2.5 ACHoractualtest_________CopyrightHRAIResidentialVentilationWORKSHEETW3Ar08/10 W3Bline#1.FLOORAREA TotalFloorArea ft2301 3023.ALLOWABLENETSUPPLY cfm 3114.ACTUALNETEXHAUSTTVCCSupply cfm 312minuscfm 313=equals cfm 3145.REQUIREDRELIEFAIRFLOW cfmminus cfm =equalsIMBALANCE@TVCC(TotalVentilationCapacityCondition)forsystemswithmoresupplythanexhaust@TVCCAllowableNetSupply@TVCCHouseACH50ActualNetSupply@TVCC(line314)TVCCExhaustAllowableNetSupply@TVCC(line311)Note:Ifexhaustisgreaterthansupply,useworksheet#W3AActualNetSupply@TVCC(totalheatedfloorareaincludingbasement;countcrawlspaceat1/2actualarea)FloorArea(301)__________ft2xACH50(302)_________x0.037=2.ASSUMEDAIRCHANGESPERHOURAT50PASCAL'SNote:IfActual NetSupplyislessthan AllowableNetSupplynoactionTightR20000.5ACH TypicalR20001.0ACH Prairies/North(new)1.0 ACHAtlantic(new)1.5 ACH Otherprovinces(new)1.4 ACHOlderhomes2.5 ACHoractualtest_________=equals cfm3156.DESCRIPTIONOFRELIEFAIRSYSTEM7.ONSITEPRESSURIZATIONTEST Required NotRequired 316Prepared By: HRAI #: J ob Name:Signature: Date: J ob #: Official Use:RequiredReliefAirflow@TVCCNote:IfActual NetSupplyislessthan AllowableNetSupplynoactionisrequired.TightR20000.5ACH TypicalR20001.0ACH Prairies/North(new)1.0 ACHAtlantic(new)1.5 ACH Otherprovinces(new)1.4 ACHOlderhomes2.5 ACHoractualtest_________CopyrightHRAIResidentialVentilationWORKSHEETW3Br08/10 W3Cline#1.FLOORAREA TotalFloorArea ft23012.ASSUMEDAIRCHANGESPERHOURAT50PASCAL'SHouseACH50 3023.COMBUSTIONAPPLIANCEDEPRESSURIZATIONLIMITIfspillagesusceptible=5pa,flowfactor=0.022 DepressurizationLimit@CEC pa 320if"other"appliance,limit= forflowfactorusechartatleft FlowFactor 3214.ALLOWABLENETEXHAUSTcfm3225.ACTUALNETEXHAUST TVCCExhaust cfm 323minus cfm 324+plus cfm325cfm325acfm325bIMBALANCE@CEC(CriticalExhaustCondition)forsystemswithspillagesusceptiblecombustionappliances(totalheatedfloorareaincludingbasement;countcrawlspaceat1/2actualarea)DryerExhaust(default150)+plusLargeExhaustDeviceover150cfm(a)+plusLargeExhaustDeviceover150cfm(b)FloorArea(301)________ft2xACH50(302)________xFlowFactor(321)________=AllowableNetExhaust@CECmanufacturer'srating=_____paTVCCSupplyOTHERLIMIT=flowfactor5to10pa0.02210to20pa0.03620to30pa0.05930to40pa0.08040to50pa0.10150andover0.143TightR20000.5ACH TypicalR20001.0ACH Prairies/North(new)1.0 ACHAtlantic(new)1.5 ACH Otherprovinces(new)1.4 ACHOlderhomes2.5 ACHoractualtest_________cfm325c=equals cfm 3266.REQUIREDMAKEUPAIRFLOW cfmminus cfm=equals cfm 327paRequired NotRequired 328Prepared By: HRAI #: J ob Name:Signature: Date: J ob #: Official Use:+plusLargeExhaustDeviceover150cfm(c)AllowableNetExhaust@CEC(line322)8.ONSITETESTDEPRESSURIZATIONTEST7.DESCRIPTIONOFMAKEUPAIRSYSTEMRequiredMakeUpAirflow@CEC@DepressurizationLimit(line320)(Listdevicesover150CFM) ActualNetExhaust@CECActualNetExhaust@CEC(line326)Note:IfActual NetExhaustislessthan AllowableNetExhaustnoactionisrequired.OTHERLIMIT=flowfactor5to10pa0.02210to20pa0.03620to30pa0.05930to40pa0.08040to50pa0.10150andover0.143TightR20000.5ACH TypicalR20001.0ACH Prairies/North(new)1.0 ACHAtlantic(new)1.5 ACH Otherprovinces(new)1.4 ACHOlderhomes2.5 ACHoractualtest_________CopyrightHRAIResidentialVentilationWORKSHEETW3Cr08/10 W4Aline#1.EQUIPMENT Make:Model:2.LOWTEMPERATURECORRECTION 401 402 403xtimes cfm 404=equals cfm 4051.frommapinthe"TablesandCharts"sectionoftheHRAIventilationmanual2.lowestofsupplyorexhaustfromHRV/ERVmanufacturerspecsheet3.fromtableinthe"TablesandCharts"sectionoftheHRAIventilationmanual3.AIRFLOWADJUSTMENTFACTOR cfm 406minus cfm+plus cfm=equals cfm 406A cfm divideby cfm=equals 4071)theGROSSSUPPLYAIRFLOWfromHRV/ERVmanufacturerspecsheetwhichcorrespondstothelowestNETSUPPLYAIRFLOWthatmeetsorexceedsthecorrespondingcorrectedventilationratefromline405Prepared By: HRAI #: J ob Name:Signature: Date: J ob #: Official Use:Notes:TemperatureZone(note1)LowTemperatureVentilationReduction(note2)LowTemperatureAdjustmentFactor(note3)TotalVentilationCapacity(TVCfromW2)NetSupplyAirflowTotalVentilationCapacity(404)LowTemperatureCorrectedVentilationRate(405)LowTemperatureCorrectedVentilationRateAdjustedDesignGrossSupplyAirflowAdjustedDesignGrossSupplyAirflow(406A)HRVAIRFLOWADJUSTMENTSNotes:DesignGrossSupplyAirflow(note1)AirflowAdjustmentFactorCopyrightHRAIResidentialVentilationWORKSHEETW4Ar08/10 W4Bline#1.HRVAIRDELIVERYTEMPERATURE % 408DT= C 409100 C 410Note:useformulaaboveorHRVairdeliverytemperaturechartfoundintheTablesand IfHRV/ERVnotusedDT=ODTChartssectionoftheHRAIventilationmanual.2.PERCENTAGEHOUSEAIRcfm 411RAFOAF cfm 412RAF % 413Note:useformulaaboveorpercentagehouseairchartfoundintheTablesandChartssectionoftheHRAIventilationmanual3.MIXEDAIRTEMPERATURE MAT= C %100 C 414Note:useformulaaboveormixedairtemperaturechartfoundintheTablesandChartssectionoftheHRAIventilationmanual4.PREHEATING15.5 CminusC=equals C 415 Cxtimes cfmxtimes 0.57Note:Preheateronlyrequiredifmixedairtemperatureisbelow15.5C =equals watts 416Prepared By: HRAI #: J ob Name:Signature: Date: J ob #: Official Use:AirDeliveryTemperature(DT)OutdoorAirflow(OAF)(Supply)ReturnAirflow(RAF)MIXEDAIRTEMPERATUREFORCEDWARMAIRSYSTEMS JobLocation:HRV/ERVApparentSensibleEffectivenessOutdoorDesignTemperature(ODT)RAT[(RATDT)x(100%HA)]TR=15.5MATPreheater=TRxRAFx0.57ODT+[(21ODT)x%HRV/ERVeff.]%HA= x100TemperatureRise(TR)(415)ReturnAirflow(RAF)(412)PreheaterSizePercentageHouseAir(%HA)AirDeliveryTemperature(DT)(410)PercentageHouseAir(%HA)(413)MixedAirTemperature(MAT)TemperatureRise(TR)constantMixedAirTemperature(MAT)(414)MinimumMixedAirTemperatureNote:IfTR(418)isanegativenumbernoheaterisrequired.CopyrightHRAIResidentialVentilationWORKSHEETW4Br08/10 W4Cline#1.HRVAIRDELIVERYTEMPERATURE % 408 C 409100 C 410Note:useformulaaboveorHRVairdeliverytemperaturechartfoundintheTablesandChartssectionoftheHRAIventilationmanual.2.HEATING C 417minus C=equals C 418 C xtimes cfm 419xtimes DELIVEREDAIRTEMPERATUREDIRECTDUCTEDSYSTEMSORMAKEUPAIRSYSTEMSDT=JobLocationOutdoorDesignTemperature(ODT)HRV/ERVApparentSensibleEffectivenessTR=DDTDTIfHRV/ERVnotusedDT=ODTAirDeliveryTemperature(DT)DesiredDeliveredAirTemperature(DDT)TemperatureRise(TR)(418)AirDeliveryTemperature(DT)(410)TemperatureRise(TR)SystemAirflow(SAF)ODT+[(21ODT)x%HRV/ERVeff.]Note:IfTR(418)isanegativenumbernoheaterisrequired.Delivered AirTemperatureminimums:highwalldiffusers=12Cfloordiffusers=15.5Cconstant0.57=equals watts 420HeaterType HRVPostheater DirectoutsideairheaterPrepared By: HRAI #: J ob Name:Signature: Date: J ob #: Official Use:Heater=TRXSAFx0.57HeaterSizeDelivered AirTemperatureminimums:highwalldiffusers=12Cfloordiffusers=15.5CCopyrightHRAIResidentialVentilationWORKSHEETW4Cr08/10 W5SYSTEM: SmallcapacityrecirculationDOORUNDERCUTSupply Exhaust Exhaust Supply TYPE SIZE(cfm) (cfm) (cfm) (cfm) (inches)Column 1 2 3 5 7 9 10 11 TOTALCFM Prepared By: HRAI #: J ob Name:Signature: Date: J ob #: Official Use:ADJUSTEDAIRFLOWSYSTEMLAYOUTGRILLESIZEDOORUNDERCUTSBalancedventilationSupply(cfm)4CentralExhaust(designairflowXcol.6)6AIRFLOWADJUST.FACTOR(line407)(cfm)8(aspersystemlayout)(typeaorb)ROOMNAME REQUIREDAIRFLOW GRILLE/DIFFUSER DESIGNAIRFLOWANDTYPE (CSAF326table1)ExhaustCopyrightHRAIResidentialVentilationWORKSHEETW5r08/10 W6A1.EQUIPMENT 2.SYSTEMTOTALEFFECTIVELENGTHFan#. ActualLengthDuctRun:ftMake: Equivalentlengthoutsidehood:ftModel: ft ftDesignairflow: cfm ftEquipmentE.S.P.: "w.c. ft ft3.DUCTSIZE ft ft "dia.@ w.c. ftTotalEffectiveLength:ft1.EQUIPMENT 2.SYSTEMTOTALEFFECTIVELENGTHFan#. ActualLengthDuctRun: ftMake: Equivalentlengthoutsidehood: ftModel: ft ftDesignairflow: cfm ftEquipmentE.S.P.: "w.c. ft ft3.DUCTSIZE ft ft "dia.@ w.c. ftTotalEffectiveLength: ftPrepared By: HRAI#: J ob Name:Signature: Date: J ob #: Official Use:DUCTSIZINGSINGLEDUCTSketchSketchCopyrightHRAIResidentialVentilationWORKSHEETW6Ar08/10 DUCTSIZINGBRANCHEDSYSTEM1.EQUIPMENT 2.DESIGNCONDITIONSModel: cfmSystem: cfm3.OUTSIDEDUCTRUNSIZINGAirflow: cfm Diameter in"w.c.ft"w.c.4.BRANCHDUCTSIZINGRunID RunID RunIDLocation Location LocationAirflow: cfm Airflow: cfm Airflow:ActualLength ActualLength ActualLengthElbowsx__ Elbowsx__ Elbowsx__ Eff.Length ft Eff.Length ft Eff.LengthDiameter in Diameter in DiameterRect.Size x Rect.Size Rect.SizeRunID RunID RunIDLocation Location LocationAirflow: cfm Airflow: cfm Airflow:ActualLength ActualLength ActualLength ActualLengthElbowsx__ Elbowsx__ Elbowsx__Eff.Length ft Eff.Length ft Eff.LengthDiameter in Diameter in DiameterRect.Size x Rect.Size Rect.Size5.TRUNKDUCTDESIGNTRUNKI.D. cfm in x cfm in x cfm in x cfm in x cfm in x cfm in xPrepared By: HRAI #: J ob Name:Signature: Date: J ob #: Official Use:EFFECTIVELENGTHxxftinxNote:Theavailablestaticpressureistobeusedtoselectallductsizesinthefollowingsections4&5ftftftDIAMETERftftftftxcfm cfmftinxOutsideducteffectivelengthDesignAirflow:in.w.c.@Elbowsx__Eff.LengthRunIDLocationAirflow:DiameterRect.SizecfmAIRFLOW RECTANGULARSIZERunIDLocationAirflow:ActualLengthElbowsx__Eff.LengthDiameterRect.SizeinftinxW6BPressureloss,outsideduct:Availablestaticpressure:cfmEquipmentE.S.P.:CopyrightHRAIResidentialVentilationWORKSHEETW6Br08/10 1.EQUIPMENT 3.TOTALEFFECTIVELENGTHFan: Make:ftModel:ft ftHeater: Make: ftModel: ft ftDesignairflow cfm ft ft2.OPERATINGPOINT ftEquipmentESP: "w.c. ftminus ft"w.c. ftequals="w.c. 4.DUCTSIZEDUCTSIZINGPOWEREDINTAKE/MAKEUPAIRW6CActualLengthDuctRun:Equivalentlengthoutsidehood:"w.c.Sketch"dia@:Availablestaticpressure:Heaterstaticpressuredrop: TotalEffectiveLength:Prepared By: HRAI #: J ob Name:Signature: Date: J ob #: Official Use:CopyrightHRAIResidentialVentilationWORKSHEETW6Cr08/10

111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111.REQUIREDAIRFLOW 3.TOTALEFFECTIVELENGTHft high ft low ftAirflow: cfm ft ft2.SUCTIONPRESSURE ft ft ft ft ft fthighspeed "w.c. ftlowspeed "w.c. 4.INTAKEDUCTSIZEhighlow "w.c.SketchDUCTSIZINGFURNACEOUTSIDEAIRINTAKEW6D"dia@:speedSystemoperatingspeedActualLengthDuctRun:Equivalentlengthoutsidehood:TotalEffectiveLength:Note:UseactualstaticpressureatconnectionpointifpossibleIfpressure isunknownuse.1"w.c.forhighspeedand.05in.w.c.forlowspeedPrepared By: HRAI #: J ob Name:Signature: Date: J ob #: Official Use:Note:UseactualstaticpressureatconnectionpointifpossibleIfpressure isunknownuse.1"w.c.forhighspeedand.05in.w.c.forlowspeedCopyrightHRAIResidentialVentilationWORKSHEETW6Dr08/10 W6E1.PRESSURE 3.TOTALEFFECTIVELENGTHftDepressurization/pressurizationft Pa. ft ft2.AIRFLOW fttest ft Pa. ft ftft cfm ft ft cfm TotalEffectiveLength:ft OR calculation 4.DUCTSIZEform: W3AW3BW3C cfm w.cLimit:SketchDUCTSIZINGPASSIVEMAKEUP/RELIEFAIRDUCTSIZINGDesignairflow: "dia@:depressurizationatCEC(pg220Manual)excessiveflowfactortimesxnetexhaustatCECequals=DesignairflowActualLengthDuctRun:Equivalentlengthoutsidehood:Prepared By: HRAI #: J ob Name:Signature: Date: J ob #: Official Use:CopyrightHRAIResidentialVentilationWORKSHEETW6Er08/10 VENTILATIONDEVICE CONTROLSTRATEGY CONTROLDEVICE1.2.3.4.5.6.7.Prepared By: HRAI #: J ob Name:Signature: Date: J ob #: Official Use:VENTILATION SYSTEM CONTROLS W7CopyrightHRAIResidentialVentilationWORKSHEETW7r08/10 Note:Thistestisforcodecomplianceoftheventilationsystemonly.1)cfm(L/s)2)cfm(L/s)3)cfm(L/s)4) Testtobecarriedoutwhenhouseissubstantiallycompletecfm(L/s)5)cfm(L/s)6)cfm(L/s) Pa (a)Pa (b)Pa (c)1.Pa (d)Pa2.Pa (b) (a) = Pa (e)3. (b) (d) = Pa (f)Pa Pa4.Pa5.(c) (a) = Pa (g)Pa (c) (d) = Pa (h)PaPaconforms doesnotconformtothedepressurizationrequirementsofCSAF326M91.ICERTIFYTHATTHETESTHASBEENPERFORMEDINACCORDANCEWITHTHETESTPROCEDURESETOUTINCSAF326M91PARAGRAPH11.2.2.a(i)AND11.2.2b(i)capacitycapacitycapacityitmustbesimulatedandtheflowverifiedbyflowmeasurementstationNote:IfanyexhaustequipmentrequiredtorunattheCECisnotinstalledNote: Windconditionsshouldbelessthan15km/h(9mph)Largestof(g)or(h)=Dep.@CECDEPRESSURIZATION@TVCCminusCOMBUSTIONAPPLIANCESTESTINSTRUMENTNote:ThetestmustbeperformedusinganinstrumentcapableofMake:Type:DepressurizationLimit0.004 0.008 0.01 0.016OnatCEC?OnatTVCC? OnatCEC?OnatTVCC? OnatCEC?OnatTVCC? OnatCEC?OnatTVCC? OnatCEC?OnatTVCC?Dateoftest:Note:Pressure@TVCCPressure@CECEnding"Rest"PressureStarting"Rest"PressureDEPRESSURIZATION@CECminusNote:Depressurizationlimitfromleft,butnomorethan10Pa.Wind: km/h(mph)DEPRESSURIZATIONTESTREPORTPostalCode:Name:0.04TESTTESULTS10 50measuring0to60Pa.rangewithasensitivityof2Pa.TESTFIRMINFORMATION3 4 5SEEOVERFORPROCEDUREDESCRIPTIONMEASUREMENTSmm/dd/yyminusCity:EmailAddress:Phone:Address:Fax:P.C.Name:Thisisnotacombustionsystemtestorabackspillagetest.BUILDER/HOUSEEXHAUSTAPPLIANCESDescribeAllExhaustAppliancesHouseID#:capacitycapacityJobName: JobNumber:Name:Address:Tel: Fax:HRAICertification#:Signature:mm/dd/yy Date:Tel:Pa 1 2Largestof(e)or(f)[email protected] 0.20 in.w.c.Thedwellingunitandsystemsatthetimeoftest:minusorequivelantcapacity OnatTVCC? OnatCEC?LowestDepressurizationLimitDepressurizationLimitDepressurizationLimitDepressurizationLimitDepressurizationLimitCERTIFICATIONCopyrightHRAIResidentialVentilationr08/10