Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
Catalog 302 (January 2017)
C O M P L I A N TNDT Fluorescent
Inspection Products
� LED UV-A Lamps � Radiometers & Photometers
RRES90061
AMS2647
ISO3059E3022
2 | www.spectroline.com | [email protected] | (516) 333-4840
Spectronics Corporation Leading the way since 1955, setting the new standard in NDT inspection lamps.NDT plays a crucial role in everyday life. We are proud to manufacture the highest quality medium and high-intensity, compliant inspection lamps and products for use in liquid penetrant and magnetic particle NDT.
The New Standard in NDT Inspection:The new ASTM E3022-15 standard came into full effect on September 1, 2015 and many of the Spectroline® brand products in this catalog are specifically designed to meet these exacting standards. Additionally, we have developed many of our lamps to meet the strict compliances for RRES 90061 (Rolls-Royce), and to meet the regulations for safety in the Aviation and Aerospace sectors. We are proud to be at the forefront of developing safe NDT products for MPI and LPI around the world.
Global Leaders:Our products are utilized for literally hundreds of markets and applications that demand uncompromising quality and reliability. Spectroline® LED UV-A lamps and radiometers are widely used by technicians in the field around the globe – including in the military and aerospace sectors, as well as aviation, oil and gas, mining, fabrication, NDT inspection shops, alternative energy, and more.
NDT
INDU
STRI
ES
AEROSPACE ALTERNATIVEENERGY
AVIATION AUTOMOTIVE FABRICATION
MILITARY MINING NDT INSPECTION SHOPS
OIL & GAS PIPELINE
3www.spectroline.com | [email protected] | (516) 333-4840 |
aerochemicals
MEMBER OF
ASTM E3022 & RRES 90061 Compliant Lamps 4-7
Each lamp comes complete with a Certificate of Conformance & Validation Report
TRITAN™ 365 TRI-365SBLC 4-5
PowerMAX™ 365 PM-1600SBLC 6-7
ASTM E3022 Compliant Lamps 8-11
Each lamp comes complete with a Certificate of Conformance
QUADRAN™ 365 QDR-365SC 8-9
TRITAN™ 365 TRI-365HC 10-11
ASTM 2297 Compliant Digital Radiometers 12-15
ANSI and NIST Traceable
AccuPRO™ DIGITAL RADIOMETER/PHOTOMETER XP-2000 12-13
AccuMAX™ DIGITAL RADIOMETER/PHOTOMETER XRP-3000 14-15
Sample Certificates of Conformance & Validation Reports 16
Customer Service/Support 17
C O N T E N T SOur new ASTM and Rolls-Royce
compliant inspection lamps are unmatched
in quality.
PROUD MEMBERS OF:
E3022
RRES90061
AMS2647
ISO3059
4 | www.spectroline.com | [email protected] | (516) 333-4840
Multi-LED, Broad-Beam UV-A Inspection Lamp.Cool running and powerful. Features three UV-A LEDs for fluorescent inspection, plus a convenient white light LED to scan for surface flaws and illuminate dark work areas. The broad-beam configuration provides a wide coverage area. A compact head design allows access into areas inaccessible to larger UV inspection lamps.
� ASTM E3022 and Rolls-Royce RRES 90061 Compliant
TRI-365SBLC
TRITAN™ 365
BUILT-IN FANS maintain optimum light output
EASY CONTROL grip-mounted, three-way rocker switch (white light/off/UV)
RUBBER BUMPER with Borofloat® glass lens protects LEDs from damage
INTEGRAL BLACK LIGHT FILTERS reduce output of wavelengths longer than 400 nm
LONG-LASTING UV-A LENSES reduce the rate of solarization
MODULAR CONSTRUCTION for easy servicing in the field
WHITE LIGHT LED allows for scanning surface flaws
Rolls-RoyceRRES 90061
Requirements
ASTM E3022
Standard
T E S T E DT O C O M P L Y W I T H
B O T H
Surface Contour Profile at 15 in (38 cm)
TRI-365SBLC
Top Intensity Profile at 15 in (38 cm)
6(15)
(10)(5)
(0)(-5) (-15)
(-10)
(-5)(0)
(15)
(5)
Y-In
ches
(cm
)
X-Inches (cm)
µW
/cm
2
(-10)(-15)
5000
4000
2000
3000
1000
-6
-2
-4
0
64 (10)
20
42
0-2
-4-6
UV-A Beam Profile
(15) (10) (5) (0) (-5) (-10) (-15)
Y-I
nch
es (
cm)
X-Inches (cm)
(15)
(10)
(5)
(0)
(-5)
(-10)
(-15)
5000
2500
1000
200
5
ASTM E3022 and RRES 90061 Compliant Lamps
www.spectroline.com | [email protected] | (516) 333-4840 |
NOMINAL STEADY-STATE UV-A INTENSITY
at 15 in (38 cm) ➊
UV-A COVERAGE AREA
at 15 in (38 cm)at minimum 1,200 µW/cm2
VISIBLE LIGHT MEASUREMENT
WHITE LIGHT LED INTENSITY LIGHT SOURCE
4,500 µW/cm2 5.5 in (14 cm) Diameter
< 0.5 foot-candles (5 lux)
400 foot-candles (4,306 lux)
3 UV-A LEDs, 1 White light LED
LAMP HEAD DIAMETER LENGTH WEIGHT POWER
REQUIREMENTSCOOLING SYSTEM LAMP STYLE
3.25 in (8.25 cm)
8 in (20.3 cm)
1 lb (454 g)
120VAC / 12VDC (also available in 230V, 240V
and 100V versions)Built-in fan Pistol grip
Technical Features
Normalized UV IrradianceUniform Beam Pattern TRI-365SBLC at 6 in (15 cm)
* Must be used in conjunction with LH-300A for connecting
340
0
0.25
0.50
0.75
1.00
350 360 370 380
Wavelength (nm)
Wavelength (nm)
Rel
ativ
e O
utp
ut
Rel
ativ
e O
utp
ut
390 400 410 420
380
0
0.25
0.50
0.75
1.00
385 390 395 400 405 410 415 420
➀ UV-A intensity reading taken with the Spectroline® AccuMAX™ Series meter, and is factory set to the value shown.
Replacement Parts and AccessoriesIMAGE PART # DESCRIPTION
129141 Standard 8 foot (2.4 m) AC power cord
129145 Extra-long 20 foot (6.1 m) AC power cord
127933 Particulate filter assembly
128196 Faceplate with integral black light filters
BR-150A Smart AC charger
CC-370A Soft carrying case
FP-365 Rubber bumper with Borofloat® glass
IMAGE PART # DESCRIPTION
PS-200A Industrial power supply / primary cord: 8 feet (2.4 m); secondary cord: 20 feet (6.1 m)
PS-300A In-line power supply / primary cord: 8 feet (2.4 m); secondary cord: 8 feet (2.4 m)
UL-110 Long lasting lens
UVS-30 UV-absorbing spectacles
B-6* Bench mount
W-6* Bench mount with pin
WM-100* Wall mounting bracket
TRI-365DBTRI-365SBLC
6 | www.spectroline.com | [email protected] | (516) 333-4840
LED UV-A Panel Flood Lamp Designed Specifically for NDT ProfessionalsPowerMAX™ 365 Series flood lamps feature a panel of 16 powerful UV-A (365 nm) LEDs specially engineered for nondestructive testing applications. These versatile, stationary light sources can be installed overhead or in-line, and can be ganged together to provide an even wider coverage area.
� ASTM E3022 and Rolls-Royce RRES 90061 Compliant
PM-1600SBLC
PowerMAX™ 365
Surface Contour Profile at 15 in (38 cm)
PM-1600SBLC
Top Intensity Profile at 15 in (38 cm)
BUILT-IN FANS maintain optimum light output
BLACK LIGHT FILTER reduces output of wavelengths longer than 400 nm
LONG-LASTING UV-A LENSES reduce the rate of solarization
16 UV-A LEDS provide large area of coverage
EASILY MOUNTABLE for overhead inspection or in-line applications
Rolls-RoyceRRES 90061
Requirements
ASTM E3022
Standard
T E S T E DT O C O M P L Y W I T H
B O T H
UV-A Beam Profile
For applications requiring extremely large coverage areas, the PowerMAX™ 365 can be quickly ganged together longitudinally (top) or back-to-back (below) using customized, easy-to-install connecting plates and brackets.
5000
2500
1000
200
(-26)(-13)
(0)(13)
(20)(15)
(10)(5)
(-10)(-15)
(-20)
(0)
Y-In
ches
(cm
)
X-Inches (cm)
µW
/cm
2
(26)
5000
4000
2000
3000
1000
8
46
2
-4-6
-8
-2(-5)0
0-10
-50
510
-10 -5 0 5 10 (-26) (-13) (0) (13) (26)
Y-I
nch
es (
cm)
X-Inches (cm)
-8 (-20)
-6 (-15)
-4 (-10)
-2 (-5)
0 (0)
2 (5)
4 (15)
6 (15)
8 (20)
7
ASTM E3022 and RRES 90061 Compliant Lamps
www.spectroline.com | [email protected] | (516) 333-4840 |
340
0
0.25
0.50
0.75
1.00
350 360 370 380
Wavelength (nm)
Wavelength (nm)
Rel
ativ
e O
utp
ut
Rel
ativ
e O
utp
ut
390 400 410 420
380
0
0.25
0.50
0.75
1.00
385 390 395 400 405 410 415 420
PM-1600UV
PM-1600BL
340
0
0.25
0.50
0.75
1.00
350 360 370 380
Wavelength (nm)
Wavelength (nm)
Rel
ativ
e O
utp
ut
Rel
ativ
e O
utp
ut
390 400 410 420
380
0
0.25
0.50
0.75
1.00
385 390 395 400 405 410 415 420
QDR-365S
QDR-365SBL
NOMINAL STEADY-STATE UV-A INTENSITY
at 15 in (38 cm) ➊
UV-A COVERAGE AREA
at 15 in (38 cm)at minimum 1,200 µW/cm2
VISIBLE LIGHT MEASUREMENT LIGHT SOURCE
4,500 µW/cm2 15 x 6 in (38 x 15 cm)
< 0.5 foot-candles (5 lux)
16 UV-A (365 nm) LEDs
DIMENSIONS (W x L x H) WEIGHT POWER
REQUIREMENTSCOOLING SYSTEM LAMP STYLE
5.5 x 13.75 x 6 in (14 x 35 x 15 cm)
9 lbs (4 kgs)
AC power (main AC power cord supplied
with the unit)Built-in fans Panel flood
lamp
Technical Features
Ideal for:
Normalized UV Irradiance
➀ UV-A intensity reading taken with the Spectroline® AccuMAX™ Series meter, and is factory set to the value shown.
Replacement Parts and AccessoriesIMAGE PART # DESCRIPTION
128177 AC power cord
BF-365PM Black light filter assembly
CF-100 Clear glass filter assembly
127918 Particulate air filter
127935 Retainer LED assembly face plate
CC-200 Connector cable for ganging lamps
IMAGE PART # DESCRIPTION
CP-100 Top connecting plate for ganging lamps longitudinally
CP-200 Top connecting plate for ganging lamps back-to-back (2 required)
CP-300 Side connecting bracket for ganging lamps longitudinally (2 required)
UL- 110 Long lasting lens
UVS-30 UV-absorbing spectacles
PM-1600UVPM-1600SBLC
Screening of fluorescent particles
Fluorescent penetrant and magnetic particle inspection
NDT inspection booths
Uniform Beam Pattern PM-1600SBLC at 11 in (27 cm)
Aviation
8 | www.spectroline.com | [email protected] | (516) 333-4840
Powerful, Multi-LED, Broad-Beam NDT Inspection LampFeatures four UV-A LEDs plus a convenient white light LED to quickly switch between fluorescent inspection and flaw location. The broad-beam configuration produces an extremely wide coverage area, making this an ideal lamp for both in-line and hand-held applications.
� ASTM E3022 Compliant
QDR-365SC
QUADRAN™ 365
Surface Contour Profile at 15 in (38 cm) Top Intensity Profile at 15 in (38 cm)
BUILT-IN FANS maintain optimum light output
EASY CONTROL TWO intensity settings for
white light LED – high and lowRUBBER BUMPER
with Borofloat® glass lens protects LEDs from damage
INTEGRAL BLACK LIGHT FILTERS reduce output of wavelengths longer than 400 nm
LONG-LASTING UV-A LENSES reduce the rate of solarization
IN-LINE INSPECTION lamp handle pin receptacle allows for easy mounting attachments
WHITE LIGHT LED allows for scanning surface flaws
UV-A Beam Profile
(15) (10) (5) (0) (-5) (-10) (-15)
Y-I
nch
es (
cm)
X-Inches (cm)
QDR-365SC
5000
2500
1000
200
(15)
(10)
(5)
(0)
(-5)
(-10)
(-15)
6(15)
(10)(5)
(0)(-5) (-15)
(-10)
(-5)(0)
(15)
(5)
Y-In
ches
(cm
)
X-Inches (cm)
µW
/cm
2
(-10)(-15)
5000
4000
2000
3000
1000
-6
-2
-4
0
64 (10)
20
42
0-2
-4-6
ASTM E3022
Standard
T E S T E DT O C O M P L Y W I T H
9
ASTM E3022 Compliant Lamps
www.spectroline.com | [email protected] | (516) 333-4840 |
340
0
0.25
0.50
0.75
1.00
350 360 370 380
Wavelength (nm)
Wavelength (nm)
Rel
ativ
e O
utp
ut
Rel
ativ
e O
utp
ut
390 400 410 420
380
0
0.25
0.50
0.75
1.00
385 390 395 400 405 410 415 420
QDR-365S
QDR-365SBL
340
0
0.25
0.50
0.75
1.00
350 360 370 380
Wavelength (nm)
Wavelength (nm)
Rel
ativ
e O
utp
ut
Rel
ativ
e O
utp
ut
390 400 410 420
380
0
0.25
0.50
0.75
1.00
385 390 395 400 405 410 415 420
QDR-365S
QDR-365SBL
NOMINAL STEADY-STATE UV-A INTENSITY
at 15 in (38 cm) ➊
UV-A COVERAGE AREA
at 15 in (38 cm)at minimum 1,200 µW/cm2
VISIBLE LIGHT MEASUREMENT
WHITE LIGHT LED INTENSITY LIGHT SOURCE
3,700 µW/cm2 6 in (15 cm) Diameter
< 0.5 foot-candles (5 lux)
High setting: 300 foot-candles (3,229 lux)
Low setting: 10 foot-candles (108 lux)
4 UV-A LEDs, 1 White light LED
LAMP HEAD DIMENSIONS
(W x H)LENGTH WEIGHT POWER
REQUIREMENTSCOOLING SYSTEM LAMP STYLE
6 x 5.5 in(15 x 14 cm)
10 in (25 cm)
3 lbs (1.36 kg)
120VAC / 12VDC (also available in 230V, 240V
and 100V versions)Built-in fan Pistol grip
Technical Features
➀ UV-A intensity reading taken with the Spectroline® AccuMAX™ Series meter, and is factory set to the value shown.
Replacement Parts and AccessoriesIMAGE PART # DESCRIPTION
129141 Standard 8 foot (2.4 m) AC power cord
129145 Extra-long 20 foot (6.1 m) AC power cord
129162 3.5 foot (1.1 m) DC power cord for “M” series lamps
127922 Particulate filter assembly
127944 Standard faceplate
128094 Faceplate with integral black light filters
B-6 Bench mount
BP-30 Battery pack with 12V rechargeable NiMH battery
BR-150A Smart AC charger
IMAGE PART # DESCRIPTION
CC-400 Soft carrying case
FA-100 Flexible arm
FP-550 Rubber bumper with Borofloat® glass
PS-200AIndustrial power supply. primary cord: 8 feet (2.4 m); secondary cord: 20 feet (6.1 m).
PS-300AIn-line power supply. primary cord: 8 feet (2.4 m); secondary cord: 8 feet (2.4 m).
W-6 Bench mount with pin
WM-100 Wall mounting bracket
UL-110 Long lasting lens
UVS-30 UV-absorbing spectacles
Normalized UV Irradiance
QDR-365SAQDR-365SC
Uniform Beam Pattern QDR-365SC at 10 in (25 cm)
10 | www.spectroline.com | [email protected] | (516) 333-4840
High Intensity, ASTM E3022 Compliant, Compact Lamp for NDT High intensity UV-A LED output enables inspectors to detect flaws faster and with greater efficiency. Compact, reliable, and quality made.
� ASTM E3022 Compliant
TRI-365HC
TRITAN™ 365
Surface Contour Profile at 15 in (38 cm)
TRI-365HC
Top Intensity Profile at 15 in (38 cm)
(15) (10) (5) (0) (-5) (-10) (-15)
Y-I
nch
es (
cm)
X-Inches (cm)
(15)
(10)
(5)
(0)
(-5)
(-10)
(-15)
6(15)
(10)(5)
(0)(-5) (-15)
(-10)
(-5)(0)
(15)
(5)
Y-In
ches
(cm
)
X-Inches (cm)
µW
/cm
2
(-10)(-15)
10000
8000
4000
6000
2000
-6
-2
-4
0
64 (10)
20
42
0-2
-4-6
10000
5000
2500
1000
200
UV-A Beam Profile
BUILT-IN FANS maintain optimum light output
EASY CONTROL grip-mounted, three-way rocker switch (white light/off/UV)
RUBBER BUMPER with Borofloat® glass lens protects LEDs from damage
INTEGRAL BLACK LIGHT FILTERS reduce output of wavelengths longer than 400 nm
LONG-LASTING UV-A LENSES reduce the rate of solarization
MODULAR CONSTRUCTION for easy servicing in the field
WHITE LIGHT LED allows for scanning surface flaws
ASTM E3022
Standard
T E S T E DT O C O M P L Y W I T H
11
ASTM E3022 Compliant Lamps
www.spectroline.com | [email protected] | (516) 333-4840 |
IMAGE PART # DESCRIPTION
129141 Standard 8 foot (2.4 m) AC power cord
129145 Extra-long 20 foot (6.1 m) AC power cord
127933 Particulate filter assembly
127955 Standard faceplate
128196 Faceplate with integral black light filters
BR-150A Smart AC charger
CC-370A Soft carrying case
FP-365 Rubber bumper with Borofloat® glass
IMAGE PART # DESCRIPTION
PS-200A Industrial power supply / primary cord: 8 feet (2.4 m); secondary cord: 20 feet (6.1 m)
PS-300A In-line power supply / primary cord: 8 feet (2.4 m); secondary cord: 8 feet (2.4 m)
UL-110 Long lasting lens
UVS-30 UV-absorbing spectacles
B-6* Bench mount
W-6* Bench mount with pin
WM-100* Wall mounting bracket
NOMINAL STEADY-STATE UV-A INTENSITY
at 15 in (38 cm) ➊
UV-A COVERAGE AREA
at 15 in (38 cm)at minimum 1,200 µW/cm2
VISIBLE LIGHT MEASUREMENT
WHITE LIGHT LED INTENSITY LIGHT SOURCE
7,000 µW/cm2 6 in (15 cm) Diameter
< 1 foot-candles (11 lux)
400 foot-candles (4,306 lux)
3 UV-A LEDs, 1 White light LED
LAMP HEAD DIAMETER LENGTH WEIGHT POWER
REQUIREMENTSCOOLING SYSTEM LAMP STYLE
3.25 in (8.25 cm)
8 in (20.3 cm)
1 lb (454 g)
120VAC / 12VDC (also available in 230V, 240V
and 100V versions)Built-in fan Pistol grip
Technical Features
➀ UV-A intensity reading taken with the Spectroline® AccuMAX™ Series meter, and is factory set to the value shown.
Replacement Parts and Accessories
Uniform Beam Pattern TRI-365HC at 6 in (15 cm)
Finally, a HIGH INTENSITY, ASTM COMPLIANT, LED UV-A inspection lamp, with a wide beam coverage area and a uniform beam pattern.
* Must be used in conjunction with LH-300A for connecting
12 | www.spectroline.com | [email protected] | (516) 333-4840
Fast, Accurate Readings in the Palm of Your Hand AccuPRO™ meter features an advanced, microprocessor-controlled readout unit calibrated to accurately measure and display both UV-A and visible light readings for nondestructive testing applications. This compact, lightweight, battery-operated unit is ideal for use in the field or the factory.
XP-2000
AccuPRO™ Digital Radiometer/Photometer
ASTM 2297
Standard
T E S T E DT O C O M P L Y W I T H
KEY FEATURES: � Accurate readouts for UV-A irradiance as well as visible illuminance � Overall accuracy greater than ± 5% per NIST standards � Superior band-pass interference filter provides excellent cosine response � One-touch PEAK with reset functions � User-defined power save and automatic shutoff � Multi-wavelength sensor directly attached to meter by 3 ft (0.9 m) cord � Convenient on-board recharging � Powered by four rechargeable “AAA” nickel-metal hydride batteries (included) � Comes complete with AC charger and padded carrying case
MULTILINGUAL – now includes more languages. User-selectable, multilingual display settings at any operational level. Choose from English, French, German, Chinese and Spanish.
LARGE LCD SCREEN 4-digit autoranging display
PROTECTIVE RUBBER HOUSING rugged meter for better grip and to help prevent accidental breakage
THREE-BUTTON INTERFACE toggle between light measurement modes
MULTI-WAVELENGTH SENSOR sealed sensor with water-resistant housing
13
ASTM 2297 Compliant Digital Radiometers
www.spectroline.com | [email protected] | (516) 333-4840 |
Technical Features
Readout Unit
Resolution 4-digit autoranging display
Screen 128 x 64 dot pixel chip on glass STN transmissive monochrome LCD 2.25 in (5.7 cm) diagonal illuminated (backlit)
Read Update 2 Hz
Overall Accuracy Better than + 5% with reference to NIST standards
Temperature Coefficient + 0.025%/°C (0 to 50°C)
Power Requirements Four “AAA” nickel-metal hydride batteries (rechargeable). AC charger included. Available in 120V, 230V, 240V or 100V versions.
DimensionsLength 6.0 in (15.2 cm)
Width 3.0 in (7.6 cm)
Thickness 1.0 in (2.5 cm)
Weight 8 oz (227 g)
Sensor Detector
Length 3.0 in (7.6 cm)
Width 2.0 in (5.1 cm)
Thickness 0.5 in (1.3 cm)
Weight 5.6 oz (159 g)
Spectral Range
UV-A Sensor 320-400 nm
Visible Sensor 460-675 nm
Wavelength/Measurement Range
UV-A (365 nm) Irradiance 0-100 mW/cm2
Visible (555 nm) Illuminance 0-5,382 Lux (0-500 fc)
0
0
.1
.2
.3
.4
.5
.6
.7
.8
.9
10
300nm 350nm 400nm 450nm 500nm 550nm 600nm 650nm 700nm 750nm
Rel
ativ
e S
pec
tral
Res
po
nse
Wavelength (nm)
The AccuPRO™ meter features a multi-wavelength light sensor
14 | www.spectroline.com | [email protected] | (516) 333-4840
The MOST Advanced, Microprocessor-Controlled Readout SystemThe AccuMax™ XRP-3000 is compact, lightweight and battery-operated for convenient use in the factory, field or any other location where measurements need to be taken. A slide-out panel allows for easy replacement of the unit’s 9-volt batteries.
XRP-3000
AccuMAX™ Digital Radiometer/Photometer
ASTM 2297
Standard
T E S T E DT O C O M P L Y W I T H
KEY FEATURES: � Microprocessor-controlled readout unit with dual-wavelength sensor detector � Superior bandpass interference filter � Choice of direct or USB connection between sensor detector and readout unit � Excellent cosine response � Sealed sensor housing and USB connection with water-resistant adapter
MULTILINGUAL – now includes more languages. User-selectable, multilingual display settings at any operational level. Choose from English, French, German, Chinese and Spanish.
0
0
.1
.2
.3
.4
.5
.6
.7
.8
.9
10
300nm 350nm 400nm 450nm 500nm 550nm 600nm 650nm 700nm 750nm
Rel
ativ
e S
pec
tral
Res
po
nse
Wavelength (nm)
PROTECTIVE RUBBER HOUSING rugged meter for better grip and to help prevent accidental breakage
DUAL-WAVELENGTH SENSOR sealed with water-resistant housing
LARGE LCD SCREEN 4-digit autoranging display
15
ASTM 2297 Compliant Digital Radiometers
www.spectroline.com | [email protected] | (516) 333-4840 |
The perfect accessory for the AccuMAX Series meter. Ideal for technicians performing radiographic examinations. Meets ASTM E1742 standard.
The AccuMAX XS-555/L luminance sensor detector measures the brightness of a visible light source and, unlike many competitive units, allows the user the choice of displaying the results in three distinct units of measure: candelas per square meter (cd/m2), candelas per square foot (cd/ft2) and footlamberts (fL).
Technical Features
AccuMAX™ XS-555/L Luminance Sensor Detector
Readout Unit (XR-1000)
Resolution 4-digit autoranging display
Screen 128 x 64 dot pixel chip on glass STN transmissive monochrome LCD 2.25 in (5.7 cm) diagonal illuminated (backlit)
Sample Rate 7.5 Hz (single sensor) 15 Hz (dual sensor)
Read Update 2 Hz
Overall Accuracy Better than + 5% with reference to NIST standards
Temperature Coefficient + 0.025%/°C (0 to 50°C)
Power Requirements Two 9V alkaline batteries (included)
Dimensions
Length 7.75 in (19.7 cm)
Width 4.25 in (10.8 cm)
Thickness 1.25 in (3.2 cm)
Weight 0.8 lb (360 g)
Dual UV-A/Visible Sensor Detector (XDS-1000)
Irradiance Range
UV-A Sensor 0-100 mW/cm2 (0-100,000 µW/cm2)
Visible Sensor 0-5,300 lux (0-500 fc)
Spectral Range
UV-A Sensor 320-400 nm
Visible Sensor 460-675 nm
Dimensions
Length 4.75 in (12.1 cm)
Width 2.0 in (5.1 cm)
Thickness 7/8 in (2.2 cm)
Weight 0.22 lb (100 g)
USB Cable (Length) 5 ft (1.5 m)
16 | www.spectroline.com | [email protected] | (516) 333-4840
WarrantyAll equipment is warranted against defects in manufacture. Spectronics Corporation’s obligation under this warranty is limited to repairing or replacing, at the option of Spectronics Corporation, any part(s) of the product which, if properly installed, used and maintained, proves upon factory examination to have been defective in materials or workmanship within 12 months from the date of delivery to the customer, including LEDs. This warranty does not apply to any component which (1) is normally consumed in operation or (2) has a normal life inherently shorter than the warranty stated. For example, bulbs, filters and rechargeable batteries are warranted for 30 days; the 100S/M-PQL bulb is warrantied for 90 days. In addition, Spectronics Corporation does not warrant any instrument that has been subjected to misuse, negligence or accident, or has been repaired or altered by anyone other than Spectronics Corporation.This warranty is in place of all other warranties of quality. There are no other warranties either oral, written, express, implied or statutory. IMPLIED WARRANTIES OF FITNESS FOR PURPOSE AND MERCHANTABILITY ARE EXCLUDED. This warranty and your remedies thereunder are solely as stated in this form. In no event shall Spectronics Corporation be liable for special, indirect, incidental or consequential damages, nor for any damages arising out of delay in shipment or production.
Product Specifications Spectronics Corporation reserves the right to alter product specifications without notice. Spectronics is under no obligation to make similar changes in its products previously produced.
956 Brush Hollow Rd, Westbury, NY 11590 ● PHONE: 516-333-4840 ● FAX: 516-333-4859 ● WWW.SPECTROLINE.COM
VALIDATION REPORT
MODEL NUMBER: TRI-365SBLC SERIAL NUMBER: STANDARD: Rolls-Royce RRES 90061 PART NUMBER:
TEST DESCRIPTIONS
PARAMETERS TYPE TEST - NOMINAL UNIT TEST
INITIAL SWITCH ON
AFTER Ts MAX TEMP. AFTER Ts
Minimum Working Distance
5,000 µW/cm2
NA 15 inches
(38.1 cm) NA
Maximum Working Distance
1,200 µW/cm2
NA 25 inches
(63.5 cm) NA
Peak Wavelength 365 +/- 5 nm 367 +/- 2 nm 367 +/- 2 nm 368 +/- 2 nm
50% Max FW < 20 nm (FWHM)
10 +/- 1 nm 10 +/- 1 nm 10 +/- 1 nm
50% Max +/- 10 nm
-5 /+ 6 nm -5 /+ 6 nm -5 /+ 6 nm
10% Max FW < 30 nm
22 +/- 3 nm 22 +/- 3 nm 22 +/- 3 nm
10% Max +/- 15 nm
-10 /+ 15 nm -10 /+ 15 nm -10 /+ 15 nm
Wavelength Drift 360nm to 370nm
Acceptable Acceptable Acceptable
Visible Light Output
<20 Lux at Minimum Dist <5 Lux at Maximum Dist
2.15 Lux (0.20 fc) at Min
2.15 Lux (0.20 fc) at Min
2.05 Lux (0.19 fc) at Min
Output Stability Ts < 20% intensity drop,
<3% variation over 60 mins NA 5 minutes 30 minutes
Ambient Temperature
10 degrees C to 50 degrees C
25 degrees C 25 degrees C 50 degrees C
Source Life* TL70 = 70% initial intensity
TL50 = 50% initial intensity TL70 =
10,000 hours TL50 =
25,000 hours NA NA
NA = Not applicable
*TL70 is defined as seventy percent of factory tested intensity and TL50 is defined as fifty percent of factory tested intensity. These figures are valid for this model provided that the lamp is operated in accordance with manufacturer's instructions and remains in normal working condition. Users should be knowledgeable in the technology to an extent that ensures this model is maintained correctly. The statement of these figures in no way extends the standard warranty period beyond that stated in the manufacturer's Warranty Certificate included with each unit. Inspector:
Date: ________________ Ken Guidorizzi - Quality Manager
5/16 AM15041 Printed in the U.S.A
956 Brush Hollow Rd, Westbury, NY 11590 ● PHONE: 516-333-4840 ● FAX: 516-333-4859 ● WWW.SPECTROLINE.COM
CERTIFICATE OF CONFORMANCE
MODEL NUMBER: TRI-365SBLC SERIAL NUMBER: STANDARD: ASTM E3022; Type A PART NUMBER: APPARATUS 6.0 MANUFACTURER MODEL NUMBERS UV-A/Visible Meter (6.1) Spectronics Corporation AccuMax XRP-3000*
(aperture width 0.5 in.) Spectroradiometer (6.2) StellarNet UVI S3-25, NIR 3-25
Spectrophotometer (6.3) StellarNet UVI S3-25, NIR 3-25
LAMP ACCEPTANCE TEST (8.1) Requirements At Ambient: 77F (25 C)
(Stabilization, 10 min) Maximum Irradiance (7.3) At 15 inches (38 cm) µW/cm2
Emission Spectrum (7.6.4.6) Min range 300-400nm See Figure 1.0 - Pg. 2
Peak Wavelength (7.6.4.7) 360 to 370nm nm
FWHM (7.6.4.8) ≤15nm nm
Longest Wavelength at Half Maximum (7.6.4.8) <377nm nm
UV-A LED Visible Light (555nm) at 15 in. (38cm) <2 fc (21 Lux) Fc ( Lux)
Visible LED Light (555nm) at 15 in. (38cm) >200 fc (2150 Lux) Fc ( Lux)
Page 1 of 6
Rolls-Royce RRES 90061 Fully serialized Validation Reports provided with all RRES 90061 compliant lamps.
ASTM E3022 Certificates of Conformance as defined by ASTM E3022 standard for emission characteristics and requirements for LED UV-A lamps are supplied with each lamp.
Our NDT inspection lamps come with unique Certificates of Conformance and Validation Reports, so end-users know that their lamps meet industry requirements and standards.
UV-A intensity readings are taken with a Spectroline® AccuMAX™ Series Meter, and is factory set to the value shown.
Sample Certificates of Conformance & Validation Reports
We stay one step ahead of industry trends and technological innovation to ensure you get the most rugged, comfortable,
compliant lamps available today.
ISO 9001:2008Compliance with the new ISO standard reinforces the confidence that customers have in Spectronics Corporation’s commitment to quality, not only in the present but also in the future.
17www.spectroline.com | [email protected] | (516) 333-4840 |
Company Background Since 1955, Spectronics Corporation has been the industry leader of inventing and manufacturing fluorescent dyes and materials. More than six decades since its inception, the goal of Spectronics is still the same — to produce effective, top-quality products that are on the cutting edge of today’s technology with the utmost dedication to customer satisfaction. Our NDT product line is no exception. We have worked alongside NDT experts, engineers, product designers, and standards committee members to carefully develop our new compliant lamps to meet the highest standards.
SPECTRONICS HEADQUARTERS, WESTBURY NY
Product/Customer Support & Technical AssistanceProduct literature, instructions and a full staff of trained customer service representatives and technical service engineers are available for support. Additional product information and support are available on our website.
I M A G I N I N G F O R T O M O R R O W :We are excited to release several new, in-demand products very soon.
Have some feedback or product ideas? Please reach out – we would love to hear from you.Email our team at [email protected]
Authorized Distributors
Local Sales Representatives
Technical Assistance
Order Information
Get Support: [email protected]
or call (516) 333-4840
See More: Scan QR Code
Place an Order: [email protected]
NDT 01/17 A15249-4PRINTED IN USA
FOLLOW US:
aerochemicals
MEMBER OF
Proud Members of:
Get Support: [email protected]
Place an Order: [email protected]