Naval Architects, Marine Consultants & SurveyorsP.O. Box 88342, Dubai, U.A.E.Tel. No. : +9714 3454010Fax No. : +9714 3454015e-mail : [email protected]
CONDITION SURVEY
M.V. « SERSOU »
Surveyors:
B. STAMBOULI R.Y. MERZOUKI
Report No. : NMS/CONSULT/12/03/048
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
A - CERTIFICATION & RECORDS
A1 - GENERAL
Name__________________________:SERSOU_________________________________
Previous name_________________:EPSON TRADER PEPE LE MOKO__________
Vessel type_____________________:Bulk Carrier _____________________________
Builders________________________:Mitsubishi Heavy Industries Ltd- Japan___
Tonnage (Gross, Net, Deadweight): ___________GRT (69): 20.822 Tx_____
NRT : 12.246 Tx________________DWT: 34,100 _________________
Summer draft __________________:10.776 m________________________________
Length overall__________________:178.00 m________________________________
Length beetween perpendicular___________________:168.00 m____________
Moulded breadth_______________:27.00 m_________________________________
Free Board_____________________:4278 mm________________________________
Flag, Port of Registry___________:Algerian , Algiers________________________
Classification Society___________:BV______________________________________
Class___________________________:BV1 + Hull + Mach Bulk Carrier ESP_____
Engine_________________________:MITSUBISHI 6UEC60/150________________
Speed__________________________:13 knots________________________________
Owners_________________________:NOLIS___________________________________
Managers_______________________:NOLIS___________________________________
Surveyor's Name_______________: STAMBOULI & MERZOUKI _____________
Dates of Attendance____________:20/03/2012______________________________
Vessel laid up__________________:N/A______________________________________
Navispec Marine Services LLC 2
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
A2 - CERTIFICATION Issued Expires
Certificate of registry 27/03/08 /Safety Construction Certificate 10/12/09 20/04/12Safety Equipment Certificate 16/01/11 15/01/16Safety Radio Certificate 16/01/11 15/01/16International Load Line Certificate 15/08/07 20/04/12Exemption Load Line Certificate 10/12/07 20/04/12International Tonnage Certificate 19/01/95 /Suez Canal Tonnage Certificate 04/05/82 /Panama Canal Tonnage Certificate 02/05/83 /IOPP Certificate 23/02/11 20/04/12Financial responsability Certificate (water pollution)
20/02/12 20/02/13
Cranes, Derricks, Booms Certificate 26/02/11Derating Certificate 21/02/12 20/08/12Potable water Certificate / /Safe Manning Certificate 16/01/12 15/01/13Grain loading file 20/12/88 /
A3 - SURVEY RECORDS
Hull Special Survey 06/08/07 20/02/12Hull Annual Survey 24/02/11 20/02/12Machinery Special Survey 06/08/07 20/02/12Machinery Annual Survey 24/02/11 20/02/12Boiler Survey 26/08/10 20/02/12Tailshaft Survey 20/06/07Annual Load Line Survey 24/02/11 20/02/12Quadrennial cargo gear Survey 05/08/07 04/08/12Annual cargo gear Survey 26/02/11Date of Last drydocking 26/08/10Date of next scheduled drydocking 20/02/12 EXTENDED
20/04/12
Navispec Marine Services LLC 3
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
B - DOCUMENTATION & WRITTEN PROCEDURES
B1 - RECORDS Yes No
Deck, Engine & Radio logbooks XCompass error book XMaster's night order book XChronometer rate book XBilge & tanks sounding book XMovement book XChart correction log XStability record XSoundings booklet XCargo record book XWeather reports XRadar operation & maintenance XDeck & E.R. maintenance records XOil record book XLSA & FFE inspection records XAccident & incident records XMedical log X
B2 - INFORMATION
Approved stability information XTank sounding table XIMO codes of practice XCargo stowage reference book XCollision régulations XPilot books for current trading areas XNautical almanach for current year XTide tables for current year XLights list (corrected) XList of radio signals XNotice to Mariner XManoeuvring data XSOLAS & MARPOL publications XInternational Code of Signals XMedical reference guide XManufacturers ' manuals XWest of England Rule book X
Navispec Marine Services LLC 4
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
B3 - PLANS & NOTICES
General arrangement plan XFire fighting arrangement plan XDocking plan XHydrostatics Curves XCapacity plan X Muster lists XDrills & Exercises XDuties & responsabilities of ship's safety comittee XReporting of accidents & incidents XShip security in port/stoaway precautions X
Navispec Marine Services LLC 5
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
C - NAVIGATION & COMMUNICATION
C1 - BRIDGE EQUIPMENT Nb Maker Type Condition
Master gyrocompass & repeaters 1 Anschutz STD 22 Newly installed (2010)
Standard magnetic compass 1 Osaka NunotaniSeiki Co .
R165-NA Reported to be operational
Auto pilot 1 Tokyo Keiki TG-5000SN 50397
Reported to be operational
Rudder indicators 4 Reported to be operational
Course recorder N/A Not fitted
Rate of turn indicator (for river) N/A Not fitted
Chronometers 1 Quartz Reported to be operational
Barometers 1 Yanagi Reported to be operational
Navtex recorder 1 Furuno NX-700Asn 001933
Reported to be operational
Weather facsimile 1 Furuno Fax-408 sn 2718-6400
Reported to be operational
Satellite Navigator N/A Not fitted
G.P.S. 02 Furuno GP-90GP-150
Reported to be operational
Decca Navigator NA Not fitted
Loran NA Not fitted
Radars & ARPA 02 FurunoDecca
MU-231CRsn 2628Master bridjesn 114737
Reported to be operational
Navispec Marine Services LLC 6
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
Echo-sounder 1 JRC NJA-193S Reported to be operational
Sextants 2 Tamaya MS-2L Reported to be operational
Binoculars 2 SteinerVizzion
Navigator 3rd one out of order
Aldis lamp & battery 1 Shonan Kosakusho
SPM-9A Battery Missing
Navigation, NUC, deep draft & anchor lights
1 On bridge console
Reported to be operational
Whistle 1 CompressedAir
Reported to be operational
Shapes & gong 2 one in the bridge
Main Engine emergency stop - - On bridge console
Reported to be operational
Bow trhuster control NA Not fitted
Flags - - - Available in Bridge wardrobe
Charts - - - Satisfactory set of charts is available
C2 – GMDSS (A1, A2, A3) Maker Type Condition
SKANTI HF/MF/DSC
Skanti TRP 1000
Reported to be operational
A1+A2+A3 See below list as per C3
All required equipment as per SOLAS were found operational
C3 - COMMUNICATION Nb Maker Type Condition
Satcom 1 Scansat CT PCU 9000
Inmarsat C Reported to be operational
Navispec Marine Services LLC 7
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
VHF radio telephone 3 Sailor
JRC
Skanti
Sailor RT5022
JRC NCE 2211
Skanti VHF 1000
Reported to be operational
Walkie talkie 3 ICOM ICOM-IC GM 1600E
Reported to be operational
Public Adress system 1 Reported to be operational
Bridge to aft & fore deck & talkbacks
1 Not in use
Bridge to steering gear & talkback 1 Reported to be operational
Emergency telephone bridge to engine room & talkback
1 Reported to be operational
Navispec Marine Services LLC 8
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
D - FIRE FIGHTING & LIFE SAVING EQUIPMENT
D1 - FIRE FIGHTING APPLIANCES
Yes No Nb Condition
Fire pump X 2 Reported in Good Working Condition
Fixed fire/smoke/gas detection system
X 15 All found in operationSmoke and Heat detectors covering Engine Room only
Holds CO² system NA Not fitted
Engine room CO² system NA Not fitted
Emergency Generator Room CO² system
NA Not fitted
Engine room Fixed foam installation or equivalent
X 1 Reported in Good Working Condition
Fire main X Good Condition
Fire hydrants X 25 Reported in Good Working Condition
Fire flaps (hold/tank, Accomodations, engine room)
X All verified in good working condition.
Hose boxes X 14 10 on Deck04 in Enige RoomFound in Good Condition
Fire hoses & nozzles X 12 8 on Deck (3 pces. New)4 in Engine RoomAll Dia= 2’’1/2
Navispec Marine Services LLC 9
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
Portable fire extinguishers X 21 CO2 6.7Kg (3 Pces. on Deck)CO2 2.0Kg (2 Pces. on Deck + 2 Pces in E/R)Foam 9l (12 Pces. on Deck + 8 in E/R)Dry Powder 9Kg (1 Pce. on Deck + 2 in E/R)Trolley Dry Powder 1 Pce in E/RAll the above found in Good Condition
International shore connection
X 1 Located on Bridge
Breathing apparatus self contained
X 4 Located in Master meeting room, Steering Gear, ECR and Fire locker
Breathing apparatus bellows type or equivalent
X 13 EEBD04 Pces in oder due to unavailability of service in Algeria for refillingThe rest in Good Condition
Oxygen resuscitator X 1 In Good Condition
Fire suits X 2 In Good Condition
Alarm bells & klaxons X 13 In Good Condition
Deck foam system X Not fitted
Portable gas & oxygen detection meters
X 1 In Good Condition
Navispec Marine Services LLC 10
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
D2 - LIFE SAVING EQUIPMENT
Yes No Nb Condition
Lifeboats X 2 PS with sailsStbd.S.: Engine DrivenMaintained in Good Condition
Davits & running gear X 2 Last Load Test Aug. 2010Falls Renewed 10-Dec-2009All maintained in Good Condition
Lifeboat equipment, stores & pyrotechnics
X 2 Sets
Maintained in Good Condition as per related SOLAS Requirements.Validity dates have been confirmed
Liferafts & release gears X 3+1
3 Pces aft for (25 + 25 + 6 persons)1 Fwd.All maintained in Good Condition within the validity dates.
Lifebuoys; lights & smoke floats
X 2 PS : expiry date Aug. 2013SS: expiry date April 2014All in Good Condition
Lifejackets X 45+6
45 for adults + 6 for enfantsAll maintained in General Good Condition
Immersion suits X 46 Form E in Safety Equipment Certificate to be corrected indicating total of 32Pces.46 Pces on board maintained in General Good Condition
Line throwing apparatus & ship's pyrotechnics
X Set Found as per related SOLAS requirements.Validity dates were confirmedAll maintained in General Good Condition
First aid boxes X 4 Located on BridgeAll maintained in General Good Condition
Navispec Marine Services LLC 11
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
Dispensary & medical stores
X Set Serviced by Monrovia Port Health Authority on 12 July 2011All maintained in General Good Condition
Navispec Marine Services LLC 12
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
E - STRUCTURE & CONDITION
E1 - HULL Condition
External shell plating & coating The external shell plating is in general good condition as far as it could be seen. There are scattered small soft indentations and rusty spots around the shell plating. The coating of the topside is generally in fair condition. No significant corrosion or damage was observed.
Weather deck & fittings Weather deck plating, bulwarks, guard rails, deck piping, etc, are generally in satisfactory condition. No significant damage was noticed, only fewl spots of corrosion were noticed on the weather deck .
Forecastle Deck and fittings Deck plating found generally in sound condition.Windlasses, bits and fairleads found in maintained general good condition.
Poop Deck and fittings Deck plating found generally in sound condition.Capstans, bits and fairleads found in maintained general good condition.
Superstructure decks Plating is found generally in sound condition and well maintained.
Load line items Load line marks are properly painted.Vent pipes, sounding pipes, watertight/weathertight openings, scuppers were found maintained in general good condition.
Navispec Marine Services LLC 13
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
E2 - CARGO SPACES Condition
Number of hatches/holds She is designed with 5 cargo holds with hydraulically operated hatch covers.Found maintained in general good conditionPaint condition is fair to good
Hatchcovers Hatch covers are steel folding type, single skinned panels , hydraulically operated . Hatch coaming tables and stays are maintained in good condition. Compression bars, cleats, wheels, etc are maintained in general good condition. Rubber packing is almost new with negligible permanent imprint.No. 1 cargo hold has two hatch covers (2 panels Fwd. + 1 panel aft)Nos. 2, 3, 4 & 5 cargo holds have two hatch covers (2 panels Fwd. + 2 panel aft)
Stern ramps, Bow door, Side door & indicators
N/A
Internal shell plating All cargo holds were inspected empty and clean. The cargo holds were maintained in general good condition. The internal shell plating with its attached frames were observed to be in general overall Good condition. No significant corrosion or damage was noticed in all cargo hold.Painting condition on side shell plating was found Good.
Bukheads, frames, stringers, brackets & stiffeners
Corrugated Watertight bulkheads, frames, Stool plating were found maintained in good condition.No significant corrosion or damage was noticed in all cargo hold.Painting condition was found to be generally Good with less than 2% peeling of due to residual previous cargo (sugar) melting down in way of connection between the underdeck members and the bulkheads.
Navispec Marine Services LLC 14
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
Coatings The coating was found to be maintained in general good condition. No significant signs of corrosion/pitting were observed in all cargo holds
Tween decks, tween deck covers & guardrails
N/A
Tank tops, manholes & tank top sheating
Generally found to be maintained in satisfactory condition.Soft buckling was observed on tank top plating located between the under tank top longitudinal framing essentially due to cumulative cargo operation. No significant structural damage was observed.
Hold bilges & Strum boxes Hold bilges were inspected internally and found to be sound but corroded. No means of corrosion prevention have been applied to them.
Spar ceiling N/A
Watertight doors & access arrangement
Access hatches are in sound condition. Rubber gaskets are new.
Ladders & platforms Found maintained in general good condition.In No.1 Cargo Hold at the Fwd. lower Australian ladder platform a small section of handrails +/- 1m is missing
Lighting Found maintained in general good condition.
Ventilation system & trunking Found maintained in general good condition.
Air & souding pipes inside cargo spaces
N/A
Tank anodes N/A
Containers securing points below deck
N/A
Containers cell guides N/A
Navispec Marine Services LLC 15
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
Refrigerated Containers plug points below deck
N/A
Navispec Marine Services LLC 16
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
E3 - BALLAST TANKS Condition
FORE PEAK TANK
Ballast tank Reference FORE PEAK TANK
Internal plating Plating was found maintained in general good condition.Scattered superficial rust spots were observed but no hard scale was found. No structural damage or excessive wastage was observed.
Bulkheads, frames, stringers; brackets & stiffeners
There is superficial rust on frames, bulkheads, etc, but no significant corrosion or damage was observed.
Coatings Coating was found effective as follow:60% Top Tank Area80% Mid and bottom tank areas
Air & souding pipes inside ballast tanks
Generally found to be in satisfactory condition.
Pipelines inside ballast tanks Generally found to be in satisfactory condition.
Anodes The tank fitted with Anode protection.80% of anodes are still effective
TST No. 3 Port
Ballast tank Reference TST No. 3 Port
Internal plating Plating was found maintained in general good condition.Scattered superficial rust spots were observed but no hard scale was found. No structural damage or excessive wastage was observed.
Navispec Marine Services LLC 17
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
Bulkheads, frames, stringers; brackets & stiffeners
There is superficial rust on frames, bulkheads, etc, but no significant corrosion or damage was observed.
Coatings The coating is generally 90% effective
Air & souding pipes inside ballast tanks
Generally found to be in satisfactory condition.
Pipelines inside ballast tanks Generally found to be in satisfactory condition.
Anodes The tank fitted with Anode protection.80% of anodes are still effective
TST No. 3 Stbd.
Ballast tank Reference TST No. 3 Stbd.
Internal plating Plating was found maintained in general good condition.Scattered superficial rust spots were observed but no hard scale was found. No structural damage or excessive wastage was observed.
Bulkheads, frames, stringers; brackets & stiffeners
There is superficial rust on frames, bulkheads, etc, but no significant corrosion or damage was observed.
Coatings The coating is generally 70% effective
Air & souding pipes inside ballast tanks
Generally found to be in satisfactory condition.
Pipelines inside ballast tanks Generally found to be in satisfactory condition.
Anodes The tank fitted with Anode protection.80% of anodes are still effective
Navispec Marine Services LLC 18
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
AFT PEAK TANK
Ballast tank Reference AFT PEAK TANK
Internal plating Plating was found maintained in general good condition.Scattered superficial rust spots were observed but no hard scale was found. No structural damage or excessive wastage was observed.
Bulkheads, frames, stringers; brackets & stiffeners
There is superficial rust on frames, bulkheads, etc, but no significant corrosion or damage was observed.
Coatings The coating is generally 70% effective
Air & souding pipes inside ballast tanks
Generally found to be in satisfactory condition.
Pipelines inside ballast tanks Generally found to be in satisfactory condition.
Anodes The tank fitted with Anode protection.80% of anodes are still effective
Navispec Marine Services LLC 19
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
E4 - DECK FITTINGS & EQUIPMENT Condition
Ventilation cowl, mushroom head & closing arrangements
Maintained in general good condition.
Watertight doors to masthouse, storeroom & accomodation
Maintained in general good condition.Rubber gasket found to be still soft.
Air pipes, spark arrestors, sounding pipes & caps
Maintained in general good condition.
Ballast valves & lines on deck Maintained in general good condition.No sign of leaks were observed.
Hydraulic lines on deck Maintained in general good condition.No signs of leaks were observed
Bunker manifold diptray Maintained in general good condition.No signs of leaks were observed.Drip tray found clean.
Air pipes save all & scupper plugs arrangement
Maintained in general good condition.
Ladders, steps; catwalks, gratings & handrails
Maintained in general good condition.
Gangways & accomodation ladders
Maintained in general good condition.
Derricks & cranes The vessel is fitted with 4 pedestal mounted cranes of 20 Mt SWL located on Main Deck at centre line between cargo holdsAll cargo gear was reported to be operational, but no test could be carried out. No damage was observed.
Winches Maintained in general good condition.
Windlasses & capstans Maintained in general good condition.
Anchors & cables Found in general good condition.
Navispec Marine Services LLC 20
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
Fairleads & bitts Maintained in general good condition.
Mooring ropes & wires Found in general good condition.
Pilot ladders & hoists Maintained in general good condition.
Deck lighting Maintained in general good condition.
Containers securing point above deck
N/A
Container securing & lashing devices
N/A
Refrigerated container plug point above deck
N/A
Navispec Marine Services LLC 21
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
E5 - MACHINERY SPACE
MAIN & AUXILIARY PLANT & EQUIPMENT
F1 - PROPULSION
Type of main propulsion Motor
Rated Horse Power of M.E.__________:9720 HP @ 124rpm
Fixed or variable propeller Fixed
Single or twin propeller Single
Bow thruster Yes No
Rated Horse Power of bow thruster__:_____________________N/A___________
Stern thruster Yes No
F2 – MAIN ENGINE
Main Engine data NO Maker Type ConditionMain Engine 01 Mitsubishi-UE 6UEC 60/150H GoodAlarm system 01 NABCO Good
Loaded BallastPower setting Rpm Speed
(knot)Consumpti
on (tonnes/
day)
Speed(knot)
Consumption
(tonnes/ day)
Maximum ratingNormal power90 % NormalMost economic
128
102.4
13
11.5
32.66
18.80
14.5
12..5
31.73
18.26
Type of fuel_________________________:HFO 180___________________________
F3 – POWER GENERATION
Type of power generation Diesel driven Turbine
driven
Shaft
driven
Navispec Marine Services LLC 22
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
F4 – CONSUMPTION
F.4.1. Generating plant
Dayly fuel consumption at sea (tonnes)__________:1.7 ton/Day___________
Dayly fuel consumption in Port (tonnes)_: 2.0 ton/Day with Cranes_______
Dayly fuel consumption in Port (tonnes)_: 1.6 ton/Day without Cranes___
Type of fuel used____________________:MDO ______________________________
Condition
Main engine (& alarm system)
Reported to be fully operational and in good condition through spot check of documentation on board, running hours, service reports,…No visible signs of leaks were observed.Alarms system was found fully operational. No inhibited alarms were observed.
Electrical generators (& alarm system)
Reported to be fully operational and in good condition through spot check of documentation on board, running hours, service reports,…No visible signs of leaks were observed.Alarms system was found fully operational. No inhibited alarms were observed.
Emergency generator &/or emergency batteries
Emergency generator was tested and found fully operational. No visible signs of leaks were observed.Emergency batteries (GMDSS) found to be well maintained and operational.
Cleanliness of control room, machinery spaces, bilges
All machinery spaces including engine control room, bilges, bilge wells, workshop and emergency escape routes were found clean and tidy.
Cleanliness & safety of switchboard
Both Main and Emergency Switchboards were found clean. Both of them were found fully operation. There respective safeties were reported to be in good working order.
Navispec Marine Services LLC 23
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
Boiler The boiler is of a composite type.Boiler found operational. It was reported that all its safeties and shutdowns were operational.Its foundations were found sound with no signs of corrosion. To the extend that was possible, valve connections and valves were found in apparent good external condition. All easing gear connection were found maintained in good order.
Main engine, generator & boiler lagging
Generally found to be in satisfactory condition.
Steering gear Reported to be in fully operational.Steering gear room was found clean and tidy without any visible signs of leaks.Rams (two) were found to have a smooth surface without any signs of scratches.
Emergency steering gear Ensured by the supply of one of the hydraulic steering pump (No. 2) through the emergency switchboard.Fully operational
Oily water separator & slop tanks
Reported to be operational. No test carried out.No signs of leaks were observed.
Sewage tank The vessel is fitted with a sewage treatment plant and a holding tank. The system was found fully operational.
Drinking water treatment UV Sterilizer not in operation.Mineral water is suplied for drinking.
Lubricating & fuel oil separators
She is fitted with 3 fuel oil purifiers, 1 diesel oil purifier and 1 lube oil purifiers. All of them were made reported to be operational.
Compressors The vessel is fitted with 2 main air compressors. Both reported to be operational
Turbo blowers One (1) turbo charger reported in Good Working conditionTwo (2) Blowers reported in Good working condition.
Domestic refrigerating equipment
Two reefer compressors were found to be operational.
Sanitation arrangement Found to be in satisfactory condition.
Navispec Marine Services LLC 24
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
Overboard discharge & inlet valves
Found to be in sound condition. No leakage was observed.
Bilge system Bilge pump was found to be operational.
Ballast system Ballast pumps was found to be operational.Main Ballast pump: 600 m3/hFire, GS, Bilge & Ballast pump: 200 m3/h
Shaft tunnel & stern gland No Shaft Tunnel fitted.Inner Stern tube seal arrangement found without any signs of leakages.The vessel is provided with a spare intermediate shaft.
Remote stops (main engine & vent fans)
Not tested.Reported to be operational
Remote closing devices Not tested.Reported to be operational
Workshops Found clean and tidyFitted with lathe, grinder, injection testing device
Lighting All machinery spaces found to be well lit. No damages of lights and light fixtures were observed
Emergency lighting Found in good operation.
Bunker tank gauging system Manual gauging/souding
Navispec Marine Services LLC 25
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
E6 - ACCOMODATION, GALLEY, STOREROOMS
Condition
Fire hazards in accomodation & galley
No fire hazard was observed.
Cleanliness of public rooms & alleyways
Found clean and tidy
Cleanliness of W.C. & Washrooms
Found clean and tidy
Cleanliness of hospital Found clean and tidy
Cleanliness of galley Found clean and tidy
Dry storerooms & provisions Generally found reasonably clean and tidy.
Refrigerated storerooms and provisions
Refrigeration in Fish and Dairy Rooms was found stopped and used as Dry Stores because of not enough fish and dairy product on board (Reason given by ships crew)Meat and Vegetable Rooms were found operational within recommended temperatures.All above mentioned store room were found generally reasonably clean and tidy.
Navispec Marine Services LLC 26
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
F - CONCLUSION
The vessel is generally structualy sound.
All Certificates are valid. They have been extended by BV Class until 20 April 2012 due to unavailability of Drydock in the area for the completion of Special Surveys Hull and Machinery. No Condition of Class is imposed by BV Class.
Last dry-docking was carried out in 26 August 2010.
Thickness measurement report was checked and all results are reasonably above the limits.
Last Condition Evaluation Report as per SOLAS requirement for ESP vessels was reviewed and reflect the good condition of the vessel.
Loading of cargoes of density 1.78 T/m3 and over is not allowed in any hold.
Navigation and communication equipment are IMO approved and were reported to be operational.
Lifesaving appliances and firefighting equipment are of an approved type and in accordance with the safety plan.
Accommodation was found in general good condition – internally and externally. Cabins and Mess Rooms are spacious, comfortable, clean and tidy.
Weather deck plating, bulwarks, guard rails, vent pipes, sounding pipes, watertight openings, deck piping, etc, are generally in satisfactory condition. No significant damage or corrosion was noticed except for the weather deck which shows spots of corrosion.
Windlass, anchors, chains, fairleads, bits, etc are generally in satisfactory condition.
There is a spare propeller on board.
The shell plating is in sound condition as far as it could be seen. There are scattered small indentations and rusty spots on the topside. The coating of the topside is generally in good condition. No significant corrosion or damage was observed.
The cargo holds were found maintained in general good condition. The internal shell plating with its attached frames were observed to be in general overall Good condition. No significant corrosion or damage was noticed in all cargo hold. Painting condition on side shell plating was found to be Good.
Navispec Marine Services LLC 27
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
Hatch covers are steel folding type, hydraulically operated. Hatch coaming tables and stays are maintained in good condition. Compression bars, cleats, wheels, etc are maintained in general good condition. Rubber packing is almost new with negligible permanent imprint.
The vessel is fitted with 4 pedestal mounted cranes ,located on Main Deck at centre line between cargo holds. All cargo gear was reported to be operational, but no test could be carried out. No damage was observed.The SWL was reduced from 25Mt to 20Mt on 05/08/2007 at owner request.
The four ballast tanks were available for inspection: Fore Peak Tank, TST 3 Port, TST 3 Stbd. And Aft Peak. Structurally, all inspected tanks were found in general sound condition. These tanks were found with anode protection. The effectiveness of their coating was as follow:
Fore Peak Tank: FAIRo 60% Top Tank Areao 80% Mid and bottom tank areas
TST 3 Port: FAIR to GOODo 90% overall
TST 3 Stbd.: FAIRo 70% overall
Aft Peak Tank: FAIRo 70% overall
The engine room was found clean and tidy with no signs of leakages. From the records reviewed, it seems well maintained as per the maintenance plan and as per the manufacturers’ recommendations.
Main Engine was found in general external good condition with no signs of leaks. The engine was not tested at this time but a review of its running data showed that all parameters were within the manufacturer recommendation. A review of the maintenance record has shown that there are no overdue items.
The three (3) Auxilliary Engines were found in general external good condition with no signs of leaks. Both A/E # 2 & 3 were seen under load. A review of their running data showed that all parameters were within the manufacturer recommendation. A review of the maintenance record has shown that there are no overdue items.
Pipes, pumps and other equipment are generally in a good external condition.
Due to international crisis and to unavailability of drydocks in Algeria to complete her Special Survey, the vessel has not carried any cargo since three months, so no any recent performance record with the ship in normal trading condition were found.
Navispec Marine Services LLC 28
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
The vessel was in a fixed trade carrying sugar from Latin America to Algeria.
Last PSC inspection report was reviewed from Paris MOU Norway dated 08 November 2011. This was an expanded inspection. Only one deficiency was reported related to hygiene in the provision store which was rectified within 2 days.
The following consumptions were reported by the Chief Engineer:
Condition Speed
(knots)
ME
HFO (t/day)
ME Cyl LO
(l/day)
Loaded
Voyage13 32.66
280
Ballast Voyage 14.5 31.73
Cylinder Oil Consumption = 1.2 g/ HP.h
Navispec Marine Services LLC 29
Condition Survey m/v : SERSOU At Bejaia road on 21/03/2012
Signed by
Navispec Marine Services LLC 30
Generators DO (t/day/DG)
Sea 1 DG’s 1.7
Port1 DG: 1.6
Cranes working: 2.0