Djoerd Hoekstra – President

William Work, PhD – VP Coatings Technology

Josh Simon, PhD – Sr Product Manager, Coatings

Configurable Biopolymer Coatings forMedical Devices

Page 2: Configurable Biopolymer Coatings for Medical Devices · 2018-04-01 · Biocoat Corporate Overview Born out of work at Columbia University in early 1980's Hydrophilic coatings based

Biocoat Corporate Overview

Born out of work at Columbia University in early1980's

Hydrophilic coatings based on Hyaluronic Acid Founded 1991

– Ellington Beavers,PhD– ~20 employees today– New 8000 sq ft facility in 2005

Applying and expanding on those technologiestoday...

Page 3: Configurable Biopolymer Coatings for Medical Devices · 2018-04-01 · Biocoat Corporate Overview Born out of work at Columbia University in early 1980's Hydrophilic coatings based

Biocoat Corporate Overview

• Products approved and sold worldwide– Japan, EU, USA, Australia

• $300+ million in product sales that use coating• New automated coating system for

applications development

Page 4: Configurable Biopolymer Coatings for Medical Devices · 2018-04-01 · Biocoat Corporate Overview Born out of work at Columbia University in early 1980's Hydrophilic coatings based

4

Hydak® Coatings

Base Coat – Hydak Platform

Top Coat

Page 5: Configurable Biopolymer Coatings for Medical Devices · 2018-04-01 · Biocoat Corporate Overview Born out of work at Columbia University in early 1980's Hydrophilic coatings based

5

Hydak® Technology Platform

Time-tested Well-understood Chemistry Isocyanate linkages Acrylic-based polymer matrix Heat cured (~60°C) Able to attach functional compounds

IsocyanatePolyacrylic

Page 6: Configurable Biopolymer Coatings for Medical Devices · 2018-04-01 · Biocoat Corporate Overview Born out of work at Columbia University in early 1980's Hydrophilic coatings based

Coating Possibilities

Hydak® Coatings...surfaces with... Hyaluronic acid-based bilaminar coating Glycosaminoglycans (GAG's) Other cellular matrix components Functional protein surfaces Anti-biofilm surfaces Bound API's

Page 7: Configurable Biopolymer Coatings for Medical Devices · 2018-04-01 · Biocoat Corporate Overview Born out of work at Columbia University in early 1980's Hydrophilic coatings based

Biocoat's Model

Customer presents a need Biocoat platform engaged Solution to problem developed Technology is licensed to clients Reagents are for sale

Page 8: Configurable Biopolymer Coatings for Medical Devices · 2018-04-01 · Biocoat Corporate Overview Born out of work at Columbia University in early 1980's Hydrophilic coatings based

8

Hydak® Base Coat

B-23K− Organic solvent-based− Most commonly used

DC-8− Aqueous-based dispersion− Good for solvent sensitive

substrates− Good for polycarbonates

and metallic substrates

Page 9: Configurable Biopolymer Coatings for Medical Devices · 2018-04-01 · Biocoat Corporate Overview Born out of work at Columbia University in early 1980's Hydrophilic coatings based

9

Hydak® Base Coat

Acrylic-based Provides adhesion to substrate

− Possibilities include: Pebax, Polyurethane, Nylon,PE, PEEK, PMMA, PVC, Stainless Steel

Provides chemistry for covalent attachment oftop coat

Flexible to accommodate mechanicaldeformation of substrate

Page 10: Configurable Biopolymer Coatings for Medical Devices · 2018-04-01 · Biocoat Corporate Overview Born out of work at Columbia University in early 1980's Hydrophilic coatings based

10

Suitable Substrates• Polyesters• Polyimides• Polyethers• Polyurethanes• Poly (ethylene-co- vinyl

acetates)• HDPE/LDPE/PP with

Plasma treatment• Silicones with Plasma

treatment

• Poly (methylmethacrylate)

• Nylon• PEBAX• Polycarbonates• PVC w/ Plasma

treatment• PEEK• Metals (SS, Pt, Ni, Ti)

Page 11: Configurable Biopolymer Coatings for Medical Devices · 2018-04-01 · Biocoat Corporate Overview Born out of work at Columbia University in early 1980's Hydrophilic coatings based

11

Hydak® Top Coat

Lubricious Biocompatible Non-thrombogenic Durable Customizable

Page 12: Configurable Biopolymer Coatings for Medical Devices · 2018-04-01 · Biocoat Corporate Overview Born out of work at Columbia University in early 1980's Hydrophilic coatings based

12

Structure of Hyaluronan

Page 13: Configurable Biopolymer Coatings for Medical Devices · 2018-04-01 · Biocoat Corporate Overview Born out of work at Columbia University in early 1980's Hydrophilic coatings based

13

Hydak® Coatings: Non-Crosslinked

Page 14: Configurable Biopolymer Coatings for Medical Devices · 2018-04-01 · Biocoat Corporate Overview Born out of work at Columbia University in early 1980's Hydrophilic coatings based

14

Hydak® Coatings:Crosslinked

Page 15: Configurable Biopolymer Coatings for Medical Devices · 2018-04-01 · Biocoat Corporate Overview Born out of work at Columbia University in early 1980's Hydrophilic coatings based

15

Hydak® Coating Process

1) Surface preparation2) Apply Base Coat3) Cure Base Coat (~ 35 to 80 C)4) Apply Top coat5) Cure Top Coat (~ 35 to 80 C)6) Wash/Inspect/Dry7) Package8) Sterilize

Page 16: Configurable Biopolymer Coatings for Medical Devices · 2018-04-01 · Biocoat Corporate Overview Born out of work at Columbia University in early 1980's Hydrophilic coatings based

16

Hydak®/AgION™Coatings with Antimicrobial

Protection

• Incorporate AgION™ silver-zeolite compoundsin base coat

• Combine advantages of hyaluronan with silverrelease

Page 17: Configurable Biopolymer Coatings for Medical Devices · 2018-04-01 · Biocoat Corporate Overview Born out of work at Columbia University in early 1980's Hydrophilic coatings based

17

Why Choose Hydak®?

Versatile platform for bio-functional surfaces Lubricity and durability can be adjusted to

application Non-thrombogenic coatings Heat-cured system: easy to coat lumens Low cost of manufacturing and setup Biocompatible Already used in the market

Page 18: Configurable Biopolymer Coatings for Medical Devices · 2018-04-01 · Biocoat Corporate Overview Born out of work at Columbia University in early 1980's Hydrophilic coatings based

18

Why Choose Hydak®?

Reproducible and reliable Biocoat's service and tech support Biocoat's adaptability Biocoat's technical knowledge

Page 19: Configurable Biopolymer Coatings for Medical Devices · 2018-04-01 · Biocoat Corporate Overview Born out of work at Columbia University in early 1980's Hydrophilic coatings based

19

Hydak® Applications

Devices: Catheters Balloons Guidewires Stents Scaffolds IOL Cartridges

Markets: Peripheral Vascular Cardiological Neurovascular Urological/GI Opthalmic

Page 20: Configurable Biopolymer Coatings for Medical Devices · 2018-04-01 · Biocoat Corporate Overview Born out of work at Columbia University in early 1980's Hydrophilic coatings based

20

Thank You