Guy W. Guillet Jr.– Sr. Field Service Technician– Program Manager (Connected Services)
Connected Services for MOV’sr
Potential Failure Curve
4/25/2019
2
Creating Connected Services Opportunity
Create Long Term Sustainability
Ensure plants ability to protect theenvironment and public health by havinga safe/reliable operation.
Help the end user make better decisions on when it is most appropriate to repair, replace, or rehabilitate particular assets.
Developing long-term inspection, maintenance, renewal, and funding strategies through remote monitoring.
Actuation Technologies Connected Services are based on Identify, Decide, Act
Decide
ActACT
DECIDE
IDENTIFY
Customer Site
Repair Recommendations, Collaboration, or Services
Customer Site
On-Premise Sensing and Data Collection
Emerson Monitoring
Expert Analysis
4/25/2019
3
Proof Of Concept Architecture Remote Connected Service
Data Transfer Expert Analysis
Master Station
Interface
Distributed Control System(Host)
Customers Existing Modbus Master Station Network
ModbusActuators
Retrieve Data Over Wireless HART
Network
Critical On-Off Asset
Critical On-Off Asset
Supported Protocols
Connecting the actuators to a single Emerson Digital Ecosystem
Equipment Used to Monitor and Gather
TEC2000 boards w/ACM
TEC2 Upgrade enhances diagnostic capability
Enhance user Interface Micro-processor reduction ( 5 to 2) Improved position encoder Supports Networking functionalities DCMlink Software compatibility Smaller PCB and fewer
components Unique wire hardness's Higher level of torque accuracy Lower power mode
4/25/2019
4
Equipment Used to Monitor and Gather
TEC2 boards w/ACM
TEC2 Upgrade enhances diagnostic capability
Enhance user Interface Micro-processor reduction ( 5 to 2) Improved position encoder Supports Networking functionalities DCMlink Software compatibility Smaller PCB and fewer
components Unique wire harnesses Higher level of torque accuracy Lower power mode
Equipment Used to Monitor and Gather
8Emerson Confidential
TEC2 – Features & Diagnostics
Real Time Clock
Event Logger Records 4800+ Events Records retained when power is
removed
Monitor 68 different actuator functions
Control mode LSO/C/A/B
Temperature, RDM status, Analog I/O (lost/high/low), common failure etc.
Lower Power mode available
ESD Delay when triggered
Valve Stall delay time
Full Stroke Test
Partial Stroke Test (PST) Can be triggered via discrete
or network Records torque log Event log records alarm
Analog Input #1 or #2 of range
Signal is 1mA above or below calibrated value
Controls temperature alarm
Firmware upgradeable
4/25/2019
5
Equipment Used to Monitor and Gather
Device for use on HART communicating instruments.
Adapts the wired HART protocol to the Wireless HART protocol.
Easy way to unleash otherwise “stranded” valve diagnostics.
Reduces unplanned shutdowns
Features
No Batteries required.
2 or 4-wire HART devices
Wireless output with >99% data reliability delivers rich HART data
Protected by industry leading Security
9Emerson Confidential
Smart Wireless THUM™ Adapter Smart Wireless Gateway 1420/1410
Network Management Easy Robust Security VPN Network Expansion
Information Management >99% Data Reliability Trending Host integration
Modbus (TCP & RTU) OPC HTTP
User Alerts
Device Management Simple Configuration Enabled by AMS
I.S. Class 1 Div 2 Approvals
DCMlink™
10Emerson Confidential
Single uniform solution for all electric actuators• Diagnose, Configure and Monitor all electric actuators from
a central location, independent of the protocol, actuator or host system
Benefits• Easy to use, next generation software based on human
centered design • Promotes single, uniform solution for all electric actuators
from EIM/Bettis• Improve maintenance efficiency, and reduce maintenance
cost• Integrates with Emerson’s PlantWeb™ solution
4/25/2019
6
DCMlink™ – Diagnostics
11Emerson Confidential
Diagnostics to detect emerging valve repair requirements Torque profile Archived torque profile Partial stroke test
Overlay test results for comparison with baseline Help customer to determine optimal maintenance time Reduce maintenance cost by avoiding unnecessary
maintenance Reduce probability of unplanned downtime
DCMlink™ – Live Trending
12Emerson Confidential
DCMlink allows live trending of critical parameters
User friendly graph to easily visualize the actuator response to a control system command
4/25/2019
7
Benefits of DCMlink™
13Emerson Confidential
Features BenefitsSNAP-ON™ to AMS (HART interface)
DCMlink runs as SNAP-ON™ to AMS Device Manager
Command Diagnostics Save, archive and overlay PST/FST profiles
Unified Platform for Electrics Actuators
TEC2, EHO, M2CP, MPA, XTE, RTS
Industry Protocols Supported Modbus, TCP-IP, RDM-Slave, Bluetooth, HART, Wireless HART
Diagnostics & Configuration Torque profiles , valve control, calibration, Setpoint management, Import & Export configuration data
Status Monitor / Event Log Alarms in NE-107 format. Live trending of asset health.
CPU Reset Ability to reset loss of power alarm
Municipal Site in Virginia
14Emerson Confidential
Proof of Concept Beta Installation Site
4/25/2019
8
Monitoring Results Achieved
15Emerson Confidential
• Assets Monitored
• Monitored Events – Seating Torque 26%-40% average to date – Enclosure Temperature 86-95 F – Run Time Varies by application & acquisition schedule – Strokes Varies by application & acquisition schedule – Motor Starts Varies by application & acquisition schedule – Stroke Time 32 Seconds (average) – Alarms 3 Close Torque in Log (700-FEV-4 11-1-17)
Asset Tag #s STATUS
700-FAV-4 700-FWV-4 700-FDV-4 700-FIV-4700-FEV-4
EIM TEC 2000 Actuators Converted to TEC2 Controls with Modbus Control and HART Wireless Monitoring.
Current Status: Operational without failure or observed deviation or abnormal operating status.
MOV Connected Services – Asset Condition Monitoring
16Emerson Confidential
4/25/2019
9
MOV Connected Services – Asset Condition Monitoring
17Emerson Confidential
Valve Tag # Date Event Status
700‐FEV‐4 8‐30‐17 Seating Torque Not Available Valve in Modulation
700‐FEV‐4 8‐30‐17 Enclosure Temp 86 F; Normal; Thermistor Control to 115 F
700‐FEV‐4 8‐30‐17 Run Time Max record per 5000 events 130 Hrs 48 Min 5 Sec
700‐FEV‐4 8‐30‐17 Motor starts 18644
700‐FEV‐4 8‐30‐17 Alarms None
700‐FEV‐4 8‐30‐17 Stroke Time 32 Sec
700‐FEV‐4 11‐1‐17 Seating Torque Not Available Valve in Modulation
700‐FEV‐4 11‐1‐17 Enclosure Temp 95 F; Normal; Thermistor Control to 115 F
700‐FEV‐4 11‐1‐17 Run Time Max record per 5000 events 133 Hrs 9 Min 42 Sec
700‐FEV‐4 11‐1‐17 Motor Starts 36509
700‐FEV‐4 11‐1‐17 Alarms Close TQ (3 recorded in Alarm Log)
700‐FEV‐4 11‐1‐17 Stroke Time 32 Sec
MOV Connected Services – Asset Condition Monitoring
18Emerson Confidential
Alert: Close Torque Alarm– 20” BAW Modulating with R7Q6‐3 Actuator. User TQ set at 85%. Factory is at 90% No current alarms in Event Log, so alarms may have been during setup.
Recommendation: We recommend monitoring Alarm Log; Verifying Mechanical stops properly set; Monitor seating torque during closing if possible (can be at the Local Display Module or if scheduled properly by data acquisition). Clear Alarm Log to discern if new alarm occurrence.
Potential Impact: May indicate issue with valve seat or limit setting or mechanical linkage to the valve. Particularly if additional alarms are logged or occur frequently. Dependent upon valve service or location in process, this could be an indicator of debris buildup in valve seating area.