23
Project No: Drawn: Date: Revision: Scale: Drawing No: Drawing: Project: Torquay, VIC., 3228 98 Pakington Street, Geelong West, Vic., 3218 T 5221 8409 F 5229 7433 [email protected] www.derbyshire.com.au ABN 80 060 577 648 DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONS Contractor must verify all dimensions and levels on site prior to the commencement of any works, ordering & or manufacture of any materials. Notify Derbyshire Homes of any discrepancies. Drawings to be read in conjunction with specifications. This drawing is protected by copyright. © 2011 Derbyshire Homes COVER SHEET CONSTRUCTION 14-66 15/12/2015 BA - Revisions: - - - # A00 A01 A02 A02A A03 A04 A05 A06 A07 A08 A09 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 DRAWING NAME: COVER SHEET GENERAL NOTES SITE PLAN FLOOR PLAN SLAB SETOUT PLAN ELEVATIONS SHT.1 ELEVATIONS SHT.2 REFLECTED CEILING PLAN ELECTRICAL PLAN ROOF PLAN SECTION 1 SECTION 2 SECTION 3 SECTION 4 SHT.1 SECTION 4 SHT.2 DOOR SCHEDULE SHT.1 DOOR SCHEDULE SHT.2 WINDOW SCHEDULE SHT.1 WINDOW SCHEDULE SHT.2 PLAN DET. & INT. ELEV - MASTER BED ENS. & WIR PLAN DET. & INT. ELEV. - BATH & BED 3 PLAN DET. & INT. ELEV. - BED 2, LAUNDRY, PANTRY & KITCHEN PLAN DET. & INT. ELEV. - KITCHEN SCALE - - 1:200 1:100 1:100 1:100 1:100 1:100 1:100 1:50 1:50 1:50 1:50 1:50 1:50 1:50 1:50 1:50 1:50 1:50 1:50 1:50 REV. - - - A A A - - - - - - - - - - A - A - - -

CONSTRUCTION - Derbyshire · as 3740 - waterproofing of wet areas in residential buildings as 3959 - construction in a bushfire prone area as 3786 - smoke alarms as 4055 - wind loadings

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CONSTRUCTION - Derbyshire · as 3740 - waterproofing of wet areas in residential buildings as 3959 - construction in a bushfire prone area as 3786 - smoke alarms as 4055 - wind loadings

Project No:

Drawn:

Date:

Revision:

Scale:

Drawing No:

Drawing:Project:

Torquay, VIC., 3228

98 Pakington Street, Geelong West, Vic., 3218

T 5221 8409 F 5229 7433

[email protected]

www.derbyshire.com.au

ABN 80 060 577 648

DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes

COVER SHEETCONSTRUCTION 14-66 15/12/2015

BA -

Revisions:- - -

#

A00

A01

A02

A02A

A03

A04

A05

A06

A07

A08

A09

A10

A11

A12

A13

A14

A15

A16

A17

A18

A19

A20

DRAWING NAME:

COVER SHEET

GENERAL NOTES

SITE PLAN

FLOOR PLAN

SLAB SETOUT PLAN

ELEVATIONS SHT.1

ELEVATIONS SHT.2

REFLECTED CEILING PLAN

ELECTRICAL PLAN

ROOF PLAN

SECTION 1

SECTION 2

SECTION 3

SECTION 4 SHT.1

SECTION 4 SHT.2

DOOR SCHEDULE SHT.1

DOOR SCHEDULE SHT.2

WINDOW SCHEDULE SHT.1

WINDOW SCHEDULE SHT.2

PLAN DET. & INT. ELEV - MASTERBED ENS. & WIR

PLAN DET. & INT. ELEV. - BATH &BED 3

PLAN DET. & INT. ELEV. - BED 2,LAUNDRY, PANTRY & KITCHEN

PLAN DET. & INT. ELEV. -KITCHEN

SCALE

-

-

1:200

1:100

1:100

1:100

1:100

1:100

1:100

1:50

1:50

1:50

1:50

1:50

1:50

1:50

1:50

1:50

1:50

1:50

1:50

1:50

REV.

-

-

-

A

A

A

-

-

-

-

-

-

-

-

-

-

A

-

A

-

-

-

Page 2: CONSTRUCTION - Derbyshire · as 3740 - waterproofing of wet areas in residential buildings as 3959 - construction in a bushfire prone area as 3786 - smoke alarms as 4055 - wind loadings

Project No:

Drawn:

Date:

Revision:

Scale:

Drawing No:

Drawing:Project:

Torquay, VIC., 3228

GENERAL NOTES14-66 15/12/2015

BA - A00 of 20

98 Pakington Street, Geelong West, Vic., 3218

T 5221 8409 F 5229 7433

[email protected]

www.derbyshire.com.au

ABN 80 060 577 648

Revisions:- - -

DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes

CONSTRUCTION

GENERAL NOTESN1:NCC 2014 BCA VOL 2ALL MATERIALS AND WORK PRACTICES SHALL COMPLY WITH,BUT NOT LIMITED TO THE BUILDING REGULATIONS 2006,NATIONAL CONSTRUCTION CODE SERIES 2014 BUILDING CODEOF AUSTRALIA VOL 2 AND ALL RELEVANT CURRENTAUSTRALIAN STANDARDS (AS AMENDED) REFERRED TOTHEREIN. UNLESS OTHERWISE SPECIFIED, THE TERM NCCSHALL REFER TO NATIONAL CONSTRUCTION CODE SERIES2014 BUILDING CODE OF AUSTRALIA VOLUME 2.ALL MATERIALS AND CONSTRUCTION PRACTICE SHALL MEETTHE PERFORMANCE REQUIREMENTS OF THE BCA. WHERE ANALTERNATIVE SOLUTION IS PROPOSED THEN, PRIOR TOIMPLEMENTATION OR INSTALLATION, IT FIRST MUST BEASSESSED AND APPROVED BY THE RELEVANT BUILDINGSURVEYOR AS MEETING THE PERFORMANCE REQUIREMENTSOF THE NCC.

N2:THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ANYHOUSE ENERGY RATING (HERS) REPORT AND SHALL BECONSTRUCTED IN ACCORDANCE WITH THE STAMPED PLANSENDORSED BY THE ACCREDITED THERMAL PERFORMANCEASSESSOR WITHOUT ALTERATION

N3:INSTALLATION OF ALL SERVICES SHALL COMPLY WITH THERESPECTIVE SUPPLY AUTHORITY REQUIREMENTS.

N4:DO NOT SCALE PLANS, USE WRITTEN DIMENSIONS ONLY.FIGURED DIMENSIONS TAKE PRECEDENCE OVER SCALEDDIMENSIONS.

N5:THE OWNER, BUILDER, SUBCONTRACTOR SHALL VERIFY ALLDIMENSIONS, LEVELS, SETBACKS AND SPECIFICATIONS PRIORTO COMMENCING ANY WORKS OR ORDERING MATERIALS ANDSHALL BE RESPONSIBLE FOR ENSURING THAT ALL BUILDINGWORKS CONFORM TO THE BUILDING CODE OF AUSTRALIA, ASCODES (CURRENT EDITIONS), BUILDING REGULATIONS, LOCALBY-LAWS AND TOWN PLANNING REQUIREMENTS. REPORT ALLDISCREPANCIES TO THIS OFFICE FOR CLARIFICATION.

N6:ALL WORKS SHALL COMPLY WITH BUT NOT LIMITED TO THEFOLLOWING AUSTRALIAN STANDARDS:AS 1288 - GLASS IN BUILDINGS – SELECTION AND

INSTALLATION.AS 1562 - DESIGN AND INSTALLATION OF SHEET ROOF AND

WALL CLADDINGAS 1684 - RESIDENTIAL TIMBER FRAMED CONSTRUCTIONAS 1860 - INSTALLATION OF PARTICLE BOARD FLOORINGAS 2047 - INSTALLATION AND SELECTION OF WINDOWSAS 2049 - ROOF TILESAS 2050 - FIXING OF ROOF TILESAS 2870 - RESIDENTIAL SLABS AND FOOTINGS.AS 2904 - DAMP PROOF COURSES AND FLASHINGSAS 3500 - PLUMBING & DRAINAGEAS 3600 - CONCRETE STRUCTURESAS 3660 - PROTECTION OF BUILDINGS FROM SUBTERRANEAN

TERMITES.AS 3700 - MASONRY IN BUILDINGS.AS 3740 - WATERPROOFING OF WET AREAS IN RESIDENTIAL

BUILDINGSAS 3959 - CONSTRUCTION IN A BUSHFIRE PRONE AREAAS 3786 - SMOKE ALARMSAS 4055 - WIND LOADINGS FOR HOUSINGAS 4100 - STEEL STRUCTURES

N7:THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANYSTRUCTURAL OR CIVIL ENGINEERING COMPUTATIONS ANDDRAWINGS; AND ALL OTHER CONSULTANTS DRAWINGS /DETAILS AND WITH ANY OTHER WRITTEN INSTRUCTIONSISSUED IN THE COURSE OF THE CONTRACT.

N8:WHERE REQUIRED TREAT AREA BENEATH FLOOR AGAINSTTERMITE INFESTATION IN ACCORDANCE WITH RELEVANTSTANDARD. CONTACT THE RELEVANT MUNICIPAL COUNCIL TODETERMINE IF THIS IS MANDATORY

N9:GLAZING, INCLUDING SAFETY GLAZING, SHALL BE INSTALLEDTO A SIZE, TYPE AND THICKNESS SO AS TO COMPLY WITH:- BCAPART 3 FOR CLASS 1 AND 10 BUILDINGS WITHIN A DESIGNWIND SPEED OF NOT MORE THAN N3; AND - NCC 2014 BCA VOL1 PART B1.4 FOR CLASS 2 AND 9 BUILDINGS.SAFETY GLASS TO BE USED IN THE FOLLOWING CASES:I) ALL ROOMS – WITHIN 500mm VERTICAL OF THE FLOOR.II) BATHROOMS – WITHIN 2000mm OF THE FLOOR.III) LAUNDRY – WITHIN 1200mm VERTICAL FROM FLOOR AND/ORWITHIN 300mm HORIZONTAL FROM ALL DOORS. IV) DOORWAY –WITHIN 300mm HORIZONTAL FROM DOORS.SHOWER SCREENS SHALL BE GRADE A SAFETY GLASS.

N10:WINDOW SIZES ARE NOMINAL ONLY, ACTUAL SIZE WILL VARYACCORDING TO MANUFACTURER. WINDOWS TO BE FLASHEDALL AROUND.

SITE ENVIRONMENT DESIGNINFORMATIONSEN1:SITE BUSHFIRE ATTACK ASSESSMENTREFERENCE DOCUMENT 'AS 3959-2009 CONSTRUCTION OF BUILDINGS INBUSH FIRE PRONE AREASTHIS PROPERTY IS ON A DESIGNATED BUSHFIRE PRONE AREABAL RATING LOW

SEN2:SITE CLASSIFICATIONSITE CLASSIFICATION AS CLASS: MREFER TO SOIL REPORT NO: 67522DATED: 20/05/215BY: INTRAX CONSULTING ENGINEERS PTY. LTD.

SEN3:DESIGN GUST WIND SPEED / WIND CLASSIFICATIONWIND RATING: N2BUILDING TIE DOWNS TO BE PROVIDED IN ACCORDANCE WITH AS1684-2006 FOR AN ASSUMED DESIGN GUST WIND SPEED / WINDCLASSIFICATION OF N3. REFER TO AS1684 FOR CONSTRUCTIONREQUIREMENTSREFER TO WIND CLASSIFICATION REPORT: 67522DATED: 20/05/2015BY: INTRAX CONSULTING ENGINEERS PTY. LTD.

SEN4:CLIMATE ZONECLIMATE ZONE FOR THERMAL DESIGN / THERMAL PERFORMANCE

ASSESSMENT: ZONE 6

SEN5:CORROSION PROTECTION OF BUILT-INSTRUCTURAL MEMBERS.

PROVIDE CORROSION PROTECTION OF BUILT-IN STRUCTURAL STEELMEMBERS SUCH AS STEEL LINTELS, SHELF ANGLES, CONNECTORS,ACCESSORIES (OTHER THAN WALL TIES) IN ACCORDANCE WITH TABLE 4.1OF AS4773.1-2010 MASONRY IN SMALL BUILDINGS, PART 1: DESIGNSUITABLE FOR AN ENVIRONMENT CLASSIFICATION SEVERE MARINE

CORROSION PROTECTION FOR SHEET ROOFINGPROVIDE CORROSION PROTECTION FOR SHEET ROOFING INACCORDANCE WITH NCC TABLE 3.5.1.1A SUITABLE FOR AN ENVIRONMENTCLASSIFICATION HIGH TO VERY HIGH

SEN6:ENERGY RATING & REQUIREMENTSBY: INTRAX CONSULTING ENGINEERS PTY. LTD.

PROVIDE R4.0 INSULATION BATTS TO ALL ROOF AREAS EXCEPT GARAGE

PROVIDE R2.5 INSULATION BATTS TO ALL EXTERNAL WALLS ECEPTGARAGE

PROVIDE ANTI-GLARE REFLECTIVE FOIL SISALATION PAPER TO ALLEXTERNAL WALLS

WINDOWS W2, W2A, W7, W7A AND W10 AND GLAZED DOOR D02 ARESINGLE GLAZED (U=5.4, SHGC=0.58) OR SIMILAR PRODUCTS WITH SAME UAND SHGC VALUE

ALL OTHER PROPOSED WINDOWS AND GLAZED DOORS ARE DOUBLEGLAZED (U=3.5, SHGC=0.64) OR SIMILAR PRODUCTS WITH SAME U ANDSHGC VALUE

ALL EXHAUST FANS MUST BE FITTED WITH A SEALING DEVICE SUCH ASSELF-CLOSING DAMPER

ALL DOWNLIGHTS SHALL BE SEALED PREVENTING AIRFLOW BETWEENINTERNAL SPACE AND ROOF SPACE

ALLOWED INTERIOR LIGHTING POWER DENSITY 5W/M2, ALLOWEDEXTERIOR LIGHTING POWER 4WW/M2

WEATHERPROOF SEALS TO ALL NEW EXTERNAL DOORS AND WINDOWS.SEALS TO RESTRICT AIR INFILTRATION AND TO COMPLY WITH THEREQUIREMENTS OF NCC 2015 CLAUSE 3.12.3.3

INSULATION INSTALLATION OF THE BUILDING SHALL COMPLY WITH THEREQUIREMENTS OF NCC 2015 CLAUSE 3.12.1.1

THE CONSTRUCTION OF ROOF, WALLS, FLOORS, AND OPENABLEWINDOWS SHALL BE CONSTRUCTED TO MINIMISE AIR LEAKAGE INACCORDANCE WITH NCC 2015 CLAUSE 3.12.3.5

INSTALLATION OF EITHER A RAINWATER TANK CONNECTED TO ALLSANITARY FLUSHING SYSTEMS, OR A SOLAR WATER HEATER SYSTEMINSTALLED IN ACCORDANCE WITH THE PLUMBING REGULATIONS 2008

THIS RATING ONLY APPLIES TO THE FLOOR PLAN, CONSTRUCTION DETAIL,ORIENTATION AND CLIMATE AS SUBMITTED AND INCLUDED IN THEATTACHED STAMPED PLAN

CHANGES TO ANY OF THESE AREAS CAN AFFECT THIS RATING AND SHALLBE VERIFIED WITH THE ENERGY RATER PRIOR TO COMMENCEMENT OFANY WORKS.

N11:STORM WATER SHALL BE TAKEN TO LEGAL POINT OFDISCHARGE AS ADVISED BY THE MUNICIPAL DRAINAGEENGINEER. CONTACT THE COUNCIL IF UNSURE OF POINT OFDISCHARGE. 90 DIA. CLASS 6 UPVC STORMWATER LINE LAIDTO A MINIMUM GRADE OF 1:100. PROVIDE INSPECTIONOPENINGS AT 9000MM C/C AND AT EACH CHANGE OFDIRECTION. THE COVER TO UNDERGROUND STORMWATERDRAINS SHALL BE NOT LESS THAN:- 100MM UNDER SOIL- 50MM UNDER PAVED OR CONCRETE AREAS- 100MM UNDER UN-REINFORCED CONCRETE OR PAVEDDRIVEWAYS- 75MM UNDER REINFORCED CONCRETE DRIVEWAYS

N12:THE BUILDER AND SUBCONTRACTOR SHALL ENSURE THAT ALLSTORMWATER DRAINS, SEWER PIPES, AND THE LIKE ARELOCATED AT A SUFFICIENT DISTANCE FROM ANY BUILDINGSFOOTING AND/OR SLAB EDGE BEAMS SO AS TO PREVENTGENERAL MOISTURE PENETRATION, DAMPNESS, WEAKENINGAND UNDERMINING OF ANY BUILDING AND IT'S FOOTINGSYSTEM.

N13:SEWER OR SEPTIC SYSTEM SHALL BE IN ACCORDANCE WITHTHE RELEVANT AUTHORITIES REQUIREMENTS.

N14:FOOTINGS NOT TO ENCROACH TITLE BOUNDARIES ANDEASEMENT LINES. OWNER AND BUILDER TO ENSURE THISDOES NOT OCCUR.

N15:FOR BUILDINGS IN CLOSE PROXIMITY TO THE BEACH ENSURETHAT ALL STEEL WORK, BRICK CAVITY TIES AND STEELLINTELS, ETC THAT ARE IMBEDDED OR FIXED INTO MASONRYBE PROTECTED IN ACCORDANCE WITH AS 3700 HOT DIPPEDGALVANISED

N16:ALL WET AREAS TO COMPLY WITH AS 3740. WALL FINISHESSHALL BE IMPERVIOUS TO A HEIGHT OF 1800mm ABOVE FLOORLEVEL TO SHOWER ENCLOSURES AND 300mm ABOVE BATHS,BASINS, SINKS AND TROUGHS IF WITHIN 75mm OF THE WALL.REFER TO CODE FOR ALL REQUIREMENTS.

N17:PROVIDE WALL TIES TO BRICKWORK AT MAXIMUM 600mm CRSIN EACH DIRECTION AND WITHIN 300mm OF ARTICULATIONJOINTS.

N18:SUB FLOOR VENTS ARE TO PROVIDE A RATE OF 7500mm SQCLEAR VENTILATION PER 1000mm RUN OF EXTERNAL WALLAND 2200mm SQ CLEAR VENTILATION PER 1000mm RUN OFINTERNAL DWARF WALLS.(LOCATED BELOW BEARER)

N19:PROVIDE CLEARANCE FROM UNDERSIDE OF BEARERS TOFINISHED GROUND LEVEL OF 150mm FOR FLOOR WITH STRIPFLOORING OR 200mm FOR FLOORS WITH PARTICLEBOARDFLOORING AND 400mm IN A TERMITE DECLARED AREA.

N20:NEW DWELLINGS, TO COMPLY WITH A 5 STAR ENERGY RATINGREPORT (H.E.R.S.)

N21:STAIR REQUIREMENTS: RISERS – 190mm MAXIMUM - 115mmMINIMUM. GOING – 355mm MAXIMUM – 240mm MINIMUM.(DOMESTIC ONLY)RISERS AND TREADS TO BE CONSTANT IN SIZE THROUGHOUTFLIGHT. PROVIDE NON-SLIP FINISH OR SUITABLE NON-SKIDSTRIP NEAR EDGE OF NOSING'S. PROVIDE CONTINUOUSHANDRAIL 1000mm MINIMUM HEIGHT TO BALCONIES ANDDECKS WHICH ARE 1000mm OR MORE ABOVE GROUND LEVEL.865mm MINIMUM HEIGHT HANDRAIL ABOVE STAIR NOSING'SAND LANDINGS. MAXIMUM OPENINGS BETWEEN BALUSTERSNOT TO EXCEED 125mm AND MAXIMUM GAP TO OPEN TREADNOT TO EXCEED 125mmFOR WIRE BALUSTRADE SEE BCA VOLUME 2 REQUIREMENTS

N22:STUMPS EXCEEDING 1200mm ABOVE GROUND TO BE BRACEDCONCRETE STUMPS- 100mm SQ UP TO 1400mm LONG (1 No. HD. WIRE)- 100mm SQ 1400mm TO 1800mm LONG (2 No. HD. WIRES)- 125mm SQ 1800mm TO 3000mm LONG (2 No. HD. WIRES)

N23:THE BUILDER SHALL TAKE ALL STEPS NECESSARY TO ENSURETHE STABILITY OF NEW AND EXISTING STRUCTURES DURINGALL WORKS.

N24:THE BUILDER SHALL ENSURE FOR THE GENERALWATERTIGHTNESS OF ALL NEW AND EXISTING WORKS.

N25:SMOKE ALARMS TO BE PROVIDED AND INSTALLED INACCORDANCE WITH AS3786. NEW DWELLINGS AND ADDITIONSWITH SLEEPING ACCOMMODATION TO BE HARD WIRED WITHBATTERY BACK UP.

N26:WHERE BUILDING IS WITHIN A DESIGNATED BUSHFIRE PRONEAREA COMPLIANCE WITH AS 3959 - IS REQUIRED TO A LEVELOF ATTACK AS CONFIRMED BY THE RELEVANT BUILDINGSURVEYOR.

N27:W.C. DOORS TO TOILET PANS LOCATED WITHIN 1.2m OF THEDOOR JAMB LIFT OFF HINGES MUST BE FITTED. OTHERWISETHE DOORS MUST SWING OUTWARDS.

N28:TERMITE CERTIFICATE (WHERE REQUIRED) TO BE INSTALLEDINSIDE METER BOX PRIOR TO OCCUPANCY PERMIT ORCERTIFICATE OF FINAL INSPECTION ISSUE.

N29:THESE NOTES ARE NEITHER EXHAUSTIVE NOR A SUBSTITUTEFOR REGULATIONS, STATUTORY REQUIREMENTS, BUILDINGPRACTICE OR CONTRACTUAL OBLIGATIONS AND UNLESSEXPRESSLY STATED OTHERWISE, ARE PROVIDED ONLY ASGUIDELINES. NO RESPONSIBILITY IS ACCEPTED FOR THEIRUSE.

N30:THESE PLANS HAVE BEEN PREPARED FOR THE EXCLUSIVEUSE BY THE CLIENT OF DERBYSHIRE FOR THE PURPOSEEXPRESSED NOTIFIED TO DERBYSHIRE. ANY OTHER PERSONWHO USES OR RELIES ON THESE PLANS WITHOUTDERBYSHIRE'S WRITTEN CONSENT DOES SO AT THEIR OWNRISK AND NO RESPONSIBILITY IS ACCEPTED BY DERBYSHIREFOR SUCH USE AND/OR RELIANCE.

N31:THE APPROVAL BY THIS OFFICE OF A SUBSTITUTE MATERIAL,WORK PRACTICE, VARIATION OR THE LIKE IS NOT ANAUTHORISATION FOR ITS USE OR A CONTRACT VARIATION.ANY SAID VARIATIONS MUST BE ACCEPTED BY ALL PARTIES TOTHE AGREEMENT AND WHERE APPLICABLE THE RELEVANTBUILDING SURVEYOR PRIOR TO IMPLEMENTING THE SAIDVARIATION.

Page 3: CONSTRUCTION - Derbyshire · as 3740 - waterproofing of wet areas in residential buildings as 3959 - construction in a bushfire prone area as 3786 - smoke alarms as 4055 - wind loadings

Project No:

Drawn:

Date:

Revision:

Scale:

Drawing No:

Drawing:Project:

Torquay, VIC., 3228

SITE PLAN14-66 15/12/2015

BA - A01 of 20

98 Pakington Street, Geelong West, Vic., 3218

T 5221 8409 F 5229 7433

[email protected]

www.derbyshire.com.au

ABN 80 060 577 648

Revisions:- - -

DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes

CONSTRUCTION

100.2

100.0

100.2

100.0

100.4

100.50

100.47100.48

100.35100.31

100.22100.1899.96

100.01

100.15

100.29

100.39100.36

100.30

100.14

99.98

99.92

99.94

99.99

100.11

100.25

100.27

PE

GP

EG

PE

GP

EG

SE

WE

RM

AN

HO

LE

ST

OR

MW

AT

ER

PO

INT

ELE

CT

RIC

ITY

PIT

ST

OR

MW

AT

ER

PIT

CA

BLE

PIT

100.04

100.19

99.79

99.65

EXPOSED AGGREGATECONCRETE DRIVEWAY

TBM TOP OFELECTRICITY PIT

RL 100.00m

MATERIALS & FINISHES SCHEDULECA1 CARPETCB COLORBONDPB PLASTERBOARD PAINT FINISHRF RENDERED FOAMTD TIMBER DECKING

REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH.

ABBREVIATIONS:DP DOWNPIPEFFL FINISHED FLOOR LEVELRL RELATIVE LEVELRWT RAINWATER TANKMB ELECTRICAL METERBOARDMG GAS METERMW WATER METERIHW INSTANTANEOUS HOT WATERG SWINGING GATE

NOTESN1:THE LOCATION OF SERVICES IS APPROXIMATE ONLY.BUILDER TO DETERMINE THE EXACT LOCATION OFSERVICES ON SITE PRIOR TO CONSTRUCTION.N2:ALL EXISTING SITE LEVELS SHOWN ON THESE DRAWINGSARE BASED ON SURVEY PLAN PREPARED BY INTRAX DWGREF NO.67522 REV. -. DATED 18.05.15. BUILDER TOCONFIRM ALL LEVELS ON SITE.N3:REFER TO ROOF PLAN FOR DETAILS OF ROOFING ANDROOF PLUMBINGN4:REFER TO STRUCTURAL ENGINEERS DRAWINGS FORDETAILSN5:MIN FALLS 1:100. SUBSOIL DRAINS TO ALL RETAININGWALLS. CONNECT TO STORMWATER SYSTEM.N6:BUILDER TO ALLOW FOR ALL NECESSARY EXCAVATION,BACKFILLING AND OTHER EARTH MOVING TO RE-ESTABLISH EXISTING GROUND LEVELS EXCEPT WHERENOTED OTHERWISEN7:LOCATION OF TITLE BOUNDARY IS BASED ONASSUMPTION THAT EXISTING FENCES REPRESENT TRUEBOUNDARY. A RE-ESTABLISHMENT SURVEY MAY BEREQUIRED.

DEVELOPMENT DATAPROPOSED DATA - NEW RESIDENCESITE AREA: 495 M2 53.28 SQ

BUILDING SITE COVERAGE (AREA M2)GROUND FLOORHOUSE: 182.66 M2 19.66 SQGARAGE: 43 M2 4.63 SQDRIVEWAY 43 M2 4.63 SQPAVING: 29.75 M2 2.45 SQ

TOTAL BUILDING AREA: 225.66 M2 24.29 SQPERCENTAGE SITE COVERAGE: 298.41 M2 60.3 %

% IMPERVIOUS SURFACES: 196.59 M2 39.72%

EQUINOX SHADOW

9AM SHADOW @ EQUINOX

12 NOON SHADOW @ EQUINOX

3PM SHADOW @ EQUINOX

1:200 @ A3

EX

IST

ING

CR

OS

SO

VE

R

FO

OT

PA

TH

AE

RIA

L AV

E.

LOT 95VACANT OF

18.05.15

LOT 93VACANT OF

18.05.15

VACANT OF18.05.15

15.00M226

º56'00''

33.00M06º56'00''

33.00M06º56'00''

15.00M226

º56'00''

GARAGEFFL: 100.25

FFL: 100.4

PROPOSEDNEW

RESIDENCE

EA

SE

ME

NT

2.0M

NO.35

9AM SHADOW @ EQUINOX

12 NOON SHADOW @ EQUINOX

3PM SHADOW @ EQUINOX

Page 4: CONSTRUCTION - Derbyshire · as 3740 - waterproofing of wet areas in residential buildings as 3959 - construction in a bushfire prone area as 3786 - smoke alarms as 4055 - wind loadings

Project No:

Drawn:

Date:

Revision:

Scale:

Drawing No:

Drawing:Project:

Torquay, VIC., 3228

FLOOR PLAN14-66 15/12/2015

BA - A02 of 20

98 Pakington Street, Geelong West, Vic., 3218

T 5221 8409 F 5229 7433

[email protected]

www.derbyshire.com.au

ABN 80 060 577 648

Revisions:- - -

DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes

CONSTRUCTION

D

F

W

DW

1,220905,8351203,590902,020903,420902,120902,63090

11020,185

1,9202,0591,8561,0821,8561,9828991,0507101,7228398991,8611,200360

1,200110

10,620240

1,070

1,9201,300

3,6142,662

899576

1,22090

4,230120

1,53090

4,65090

1,220

90 500230

6,080 90 3,620 90 1,800 90 7,315 90 1,220

7,140 1,153 1,722 3,384 1,856 2,839 2,050

2404,260

90

2,2504,590

1,5306,630

2,35090

1,820

6,990 150 12,765 240 1,070

920901,62090

2,710901,190610902,9109062090

1002,4263,1432,432

2,43290

100

7,370 20,145 5,485

2,38010,970

1,650

5,61520,2957,090

2306,170

230

906,300

240

2302,375

901,895

E/3A04

E/4A04

E/1A03

E/2A03

RD

2

RD

1

D9

D7

D5

D6

D11

D12D13

W4 W5D2

W6

W2

W1

W2A

D14

W3

D1

D4

D8

D13A

W7

W7A

D3

W12W13 W11

D10

W10 W8W9

S/2A09

S/4A11

S/3A10

S/1A08

MATERIALS & FINISHES SCHEDULEBW BRICKWORKCA CARPETCB COLORBONDCOS CONCRETE SLABPB PLASTERBOARD PAINT FINISHSC SCYON 'MATRIX' CLADDING OR SIMILAR

REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH

ABBREVIATIONS:BAL BALUSTRADEBG BOX GUTTERCOL STEEL COLUMNCSD CAVITY SLIDING DOORDP DOWNPIPEDS DOUBLE STUDSDW DISHWASHERFL FLOOR LEVELFW FLOOR WASTEFWB FEATURE WINDOW BOXING - ALUMINIUMG SWINGING GATEIHW INSTANTANEOUS HOT WATERMB ELECTRICAL METERBOARDRF RIDGE FLASHINGRH RANGEHOODRL RELATIVE LEVELRWT RAINWATER TANKSHR SHOWERST STOVETR TROUGHTS TOILET SUITEVB VANITY BASINWM WASHING MACHINEWO WALL OVEN

NOTESN1:ALL DIMENSIONS TO BE CHECK AND VERIFIED ON SITE.DO NOT SCALE FROM DRAWINGSN2:CONTRACTOR TO OBTAIN DERBYSHIRE'S PRIOR WRITTENAPPROVAL FOR ANY EXTRA WORK OR ALTERATIONS TOAPPROVED DRAWINGSN3:A FULL SET OF LAMINATED DRAWINGS ANDSPECIFICATIONS TO BE KEPT ON SITE IN GOODCONDITION AT ALL TIMESN4:SHOULD DISCREPANCIES OR ERROR BE DISCOVERED ONTHE DRAWINGS OR SPECIFICATIONS, DERBYSHIRE MUSTBE NOTIFIED IMMEDIATELYN5:ALL BUILDING WORKS TO BE COMPLETED INACCORDANCE WITH THE NCC/BCA AND TO THESATISFACTION OF THE LOCAL AUTHORITY AND ORBUILDING SURVEYORN6:REFER TO DOOR & WINDOW SCHEDULES FOR COMPLETEDIMENSIONS & DETAILSN7:WATERPROOFING OF WET AREAS, BEING BATHROOMS,SHOWERS, SHOWER ROOMS, LAUNDRIES, SANITARYCOMPARTMENTS AND THE LIKE SHALL BE PROVIDED INACCORDANCE WITH AS3740-2010: WATERPROOFING OFDOMESTIC WET AREAS

J0 JOINERY NO.

XX MATERIAL

W0 WINDOW NO.

D0 DOOR NO.

COLORBONDCORRUGATEDMETAL SHEETCLADDING

HARDWOODTIMBER

SCREEN.90X32MM

64MM GAPS

BRICKWORK

HARDWOODTIMBERSCREEN.50MM GAPS.

BRICKWORK

REFER TO ENGINEERSSTRUCTURAL

DRAWINGS FOR DETAIL

ACCESS HATCH DOOR600MM X 600MM

50MMSHOWERRECESS

50MMSHOWERRECESS

GARAGE

PASSAGE

BED 2

RO

BE

BED 3MASTER BEDBATHWIRENS

LIVING

DININGKITCHEN

L'D

RY

ENTRY

1:100 @ A3

FFL 100.4 FFL 100.4

TILESTILES

SITE BOUNDARY

SITE BOUNDARY

SIT

E B

OU

ND

AR

Y

SIT

E B

OU

ND

AR

Y

FFL 100.25

ROBE

CONCRETE

CARPET

TILES TILES

CARPETCARPET TILES TILES

TILESTILES

TIL

ES

(EA

VE

OV

ER

)

POST

COL.

COL.

COL.

COL.

DP DP

DPDPDP

(EA

VE

OV

ER

)

EX

PO

SE

DA

GG

RE

GA

TE

CO

NC

RE

TE

NOPOSTCSD

CS

D

CS

D

CSDC

SD

HWS

TAP

TAPDP

DP

EXPOSEDAGGREGATECONCRETE

Revisions:A W11 POSITION MOVED 15.12.15

A

Page 5: CONSTRUCTION - Derbyshire · as 3740 - waterproofing of wet areas in residential buildings as 3959 - construction in a bushfire prone area as 3786 - smoke alarms as 4055 - wind loadings

Project No:

Drawn:

Date:

Revision:

Scale:

Drawing No:

Drawing:Project:

Torquay, VIC., 3228

SLAB SETOUT PLAN14-66 15/12/2015

BA - A02A of 20

98 Pakington Street, Geelong West, Vic., 3218

T 5221 8409 F 5229 7433

[email protected]

www.derbyshire.com.au

ABN 80 060 577 648

Revisions:- - -

DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes

CONSTRUCTION

1506,490

1,5204,440

2,400

280 1,430

710 720 5,570

1,710

901,520

901,520

1,6504,840

5,960

E/3

E/4A04

E/1A03

E/2A03 S/2

A09

S/4A11

S/3A10

S/1A08

1506,490

1,5204,440

2,400

280 1,430

8,080 6,290 12,995 1,220

12,7051,510

1,22010,800

1,220

58013,240

1,180

1,22020,275

4,0506,8959206,9109201,800

710 720 5,570

1,710

901,520

901,520

1,6504,840

5,960

E/3A04

E/4A04

E/1A03

E/2A03 S/2

A09

S/4A11

S/3A10

S/1A08

MATERIALS & FINISHES SCHEDULEBW BRICKWORKCA CARPETCB COLORBONDCOS CONCRETE SLABPB PLASTERBOARD PAINT FINISHSC SCYON 'MATRIX' CLADDING OR SIMILAR

REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH

ABBREVIATIONS:BAL BALUSTRADEBG BOX GUTTERCOL STEEL COLUMNCSD CAVITY SLIDING DOORDP DOWNPIPEDS DOUBLE STUDSDW DISHWASHERFL FLOOR LEVELFW FLOOR WASTEFWB FEATURE WINDOW BOXING - ALUMINIUMG SWINGING GATEIHW INSTANTANEOUS HOT WATERMB ELECTRICAL METERBOARDRF RIDGE FLASHINGRH RANGEHOODRL RELATIVE LEVELRWT RAINWATER TANKSHR SHOWERST STOVETR TROUGHTS TOILET SUITEVB VANITY BASINWM WASHING MACHINEWO WALL OVEN

NOTESN1:ALL DIMENSIONS TO BE CHECK AND VERIFIED ON SITE.DO NOT SCALE FROM DRAWINGSN2:CONTRACTOR TO OBTAIN DERBYSHIRE'S PRIOR WRITTENAPPROVAL FOR ANY EXTRA WORK OR ALTERATIONS TOAPPROVED DRAWINGSN3:A FULL SET OF LAMINATED DRAWINGS ANDSPECIFICATIONS TO BE KEPT ON SITE IN GOODCONDITION AT ALL TIMESN4:SHOULD DISCREPANCIES OR ERROR BE DISCOVERED ONTHE DRAWINGS OR SPECIFICATIONS, DERBYSHIRE MUSTBE NOTIFIED IMMEDIATELYN5:ALL BUILDING WORKS TO BE COMPLETED INACCORDANCE WITH THE NCC/BCA AND TO THESATISFACTION OF THE LOCAL AUTHORITY AND ORBUILDING SURVEYORN6:REFER TO DOOR & WINDOW SCHEDULES FOR COMPLETEDIMENSIONS & DETAILSN7:WATERPROOFING OF WET AREAS, BEING BATHROOMS,SHOWERS, SHOWER ROOMS, LAUNDRIES, SANITARYCOMPARTMENTS AND THE LIKE SHALL BE PROVIDED INACCORDANCE WITH AS3740-2010: WATERPROOFING OFDOMESTIC WET AREAS

J0 JOINERY NO.

XX MATERIAL

W0 WINDOW NO.

D0 DOOR NO.

20MM SLABSETDOWN TOGARAGE DOOR

GARAGE

1:100 @ A3

-

FFL 100.4

SITE BOUNDARY

SITE BOUNDARY

SIT

E B

OU

ND

AR

Y

SIT

E B

OU

ND

AR

Y

FFL 100.25

POST

COL.

COL.

COL.

COL.

EX

PO

SE

DA

GG

RE

GA

TE

CO

NC

RE

TE

EXPOSEDAGGREGATECONCRETE

INFILLPAVINGSLAB

SH

OW

ER

SE

TD

OW

N

SH

OW

ER

SE

TD

OW

N

Page 6: CONSTRUCTION - Derbyshire · as 3740 - waterproofing of wet areas in residential buildings as 3959 - construction in a bushfire prone area as 3786 - smoke alarms as 4055 - wind loadings

Project No:

Drawn:

Date:

Revision:

Scale:

Drawing No:

Drawing:Project:

Torquay, VIC., 3228

ELEVATIONS SHT.114-66 15/12/2015

BA - A03 of 20

98 Pakington Street, Geelong West, Vic., 3218

T 5221 8409 F 5229 7433

[email protected]

www.derbyshire.com.au

ABN 80 060 577 648

Revisions:- - -

DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes

CONSTRUCTION

2,40

030

035

030

0

2,70

065

0

3,35

0

3,20

0

4,68

0

1,05

060

01,

550

W2 W1

D1RD1

W3

R.L. 100.40

R.L. 100.25

R.L. 102.95

R.L. 103.6

R.L. 103.6

R.L. 105.08

4,83

0

3,35

0

3,05

030

0

2,70

01,

200

3,90

0

W4D2

R.L. 100.40

R.L. 100.25

R.L. 102.95

R.L. 103.6

R.L. 103.33

R.L. 103.1

R.L. 104.3

W5

MATERIALS & FINISHES SCHEDULE:BW BRICKWORKCB COLORBOND ROOFINGSC SCYON 'MATRIX' CLADDING OR SIMILAR

REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH

ABBREVIATIONS:BC BARGE FLASHING & CAPPINGCOL STEEL COLUMNDP DOWNPIPE - COLOUR TO MATCH

ADJACENT WALL COLOUREXH EXHAUST DUCTFCL FINISHED CEILING LEVELFFL FINISHED FLOOR LEVELG SWINGING GATEGAS EXTERNAL GAS OUTLETIHW INSTANTANEOUS HOT WATERMB ELECTRICAL METERBOARDNGL NATURAL GROUND LINEOP OVERFLOW POPPC PARAPET CAPPINGRL RELATIVE LEVELRWT RAINWATER TANKRWH RAINWATER HEADSHR SHOWERSP SPREADER

NOTESN1:NCC 2014 BCA VOL 2ALL MATERIALS AND WORK PRACTICES SHALL COMPLYWITH, BUT NOT LIMITED TO THE BUILDING REGULATIONS2006, NATIONAL CONSTRUCTION CODE SERIES 2014BUILDING CODE OF AUSTRALIA VOL 2 AND ALL RELEVANTCURRENT AUSTRALIAN STANDARDS (AS AMENDED)REFERRED TO THEREIN. UNLESS OTHERWISE SPECIFIED,THE TERM NCC SHALL REFER TO NATIONALCONSTRUCTION CODE SERIES 2014 BUILDING CODE OFAUSTRALIA VOLUME 2.ALL MATERIALS AND CONSTRUCTION PRACTICE SHALLMEET THE PERFORMANCE REQUIREMENTS OF THE BCA.WHERE AN ALTERNATIVE SOLUTION IS PROPOSED THEN,PRIOR TO IMPLEMENTATION OR INSTALLATION, IT FIRSTMUST BE ASSESSED AND APPROVED BY THE RELEVANTBUILDING SURVEYOR AS MEETING THE PERFORMANCEREQUIREMENTS OF THE NCC.N2:GLAZING, INCLUDING SAFETY GLAZING, SHALL BEINSTALLED TO A SIZE, TYPE AND THICKNESS SO AS TOCOMPLY WITH:- BCA PART 3 FOR CLASS 1 AND 10BUILDINGS WITHIN A DESIGN WIND SPEED OF NOT MORETHAN N3; AND - NCC 2014 BCA VOL 1 PART B1.4 FORCLASS 2 AND 9 BUILDINGS.N3:THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHANY HOUSE ENERGY RATING (HERS) REPORT AND SHALLBE CONSTRUCTED IN ACCORDANCE WITH THE STAMPEDPLANS ENDORSED BY THE ACCREDITED THERMALPERFORMANCE ASSESSOR WITHOUT ALTERATIONN4:WHERE REQUIRED TREAT AREA BENEATH FLOOR AGAINSTTERMITE INFESTATION IN ACCORDANCE WITH RELEVANTSTANDARD. CONTACT THE RELEVANT MUNICIPAL COUNCILTO DETERMINE IF THIS IS MANDATORYN5:REFER SCHEDULES FOR DIMENSIONED DOOR & WINDOWELEVATIONS. WINDOW SIZES NOMINATED ARE NOMINALONLY. ACTUAL SIZES MAY VARY ACCORDING TOMANUFACTURERN6:STEPS TO DECK AS REQUIRED. 190MM MAX. RISER.250MM MIN. GOING TREADS

3,20

0

4,68

0

1,05

060

01,

550

W2 W1

D1

W3

R.L. 103.6

R.L. 105.08

4,83

0

3,35

0

3,05

030

0

2,70

01,

200

3,90

0

W4D2

R.L. 100.40

R.L. 100.25

R.L. 102.95

R.L. 103.6

R.L. 103.33

R.L. 103.1

R.L. 104.3

W5

SOUTH ELEVATION1:100E/1

WEST ELEVATION1:100E/2

MOTORISED STEELLINE SECTIONAL DOOR.COLORBOND FINISH.

ENTRYALUMINIUM &GLAZEDPIVOT DOOR

BARGEFLASHING

PARAPETCAPPING

POWDERCOATALUMINIUMWINDOWS

BRICKWORK

N.G.L.

MATRIXCLADDING

BUILDINGENVELOPE LINE

BUILDINGENVELOPE LINE

BUILDINGENVELOPE LINE

SPOTTED GUM TIMBER SCREEN.90MM X 32MM. 64MM GAPS.90X32MM BOTTOM PLATE FIXEDTO STEEL SADDLE PLATES150MM ABOVE CONCRETEFOOTING.

RENDERED50MM FOAM

PARAPETCAPPING

SOFFIT LININGRAKED 4.5MMHARDIFLEX WITHEXPRESSED JOINTS.

BARGEFLASHING

FASCIAGUTTER

COLORBONDROOFSHEETING

POWDERCOATALUMINIUMWINDOWS

COLORBONDCORRUGATEDMETAL SHEETCLADDING

SPOTTEDGUM TIMBER

SCREEN

RENDEREDBRICKWORK POST

COLORBONDCORRUGATEDMETAL SHEETCLADDING

SPOTTED GUM TIMBER SCREEN.90MM X 32MM. 64MM GAPS.90X32MM BOTTOM PLATE FIXEDTO STEEL SADDLE PLATES150MM ABOVE CONCRETEFOOTING.

N.G.L.

BRICKPARAPET .

RENDEREDFINISH

BRICKWORK

DOUBLE BRICK.RENDERED

FINISH

DOUBLE BRICK.RENDERED

FINISH

HORIZONTALSUPPORT IFREQUIREDBEHIND.

DOUBLE BRICK.RENDERED

FINISH

DOWNPIPE DOWNPIPE DOWNPIPE

1:100 @ A3

SIT

E B

OU

ND

AR

Y

SIT

E B

OU

ND

AR

Y

SIT

E B

OU

ND

AR

Y

FALL 10 DEG.

NOTE: TIMBER SCREEN NOT SHOWN FOR CLARITY

NOTE: TIMBER SCREENS NOT SHOWN FOR CLARITY

A

Revisions:A W1 WIDTH REVISED 02.11.15

Page 7: CONSTRUCTION - Derbyshire · as 3740 - waterproofing of wet areas in residential buildings as 3959 - construction in a bushfire prone area as 3786 - smoke alarms as 4055 - wind loadings

Project No:

Drawn:

Date:

Revision:

Scale:

Drawing No:

Drawing:Project:

Torquay, VIC., 3228

ELEVATIONS SHT.214-66 15/12/2015

BA - A04 of 20

98 Pakington Street, Geelong West, Vic., 3218

T 5221 8409 F 5229 7433

[email protected]

www.derbyshire.com.au

ABN 80 060 577 648

Revisions:- - -

DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes

CONSTRUCTION

2,10

0

2,10

030

030

0

2,70

01,

200

3,90

0

W7 D3

R.L. 104.3

R.L. 103.1

R.L. 100.4

W6

2,10

030

0

2,40

030

0

2,70

01,

200

2,70

0

2,70

01,

980

4,68

0

W10

W8W9

W7A

W12W13

W11

R.L. 105.08

R.L. 103.1

R.L. 100.4 R.L. 100.4

R.L. 104.3

MATERIALS & FINISHES SCHEDULE:BW BRICKWORKCB COLORBOND ROOFINGSC SCYON 'MATRIX' CLADDING OR SIMILAR

REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH

ABBREVIATIONS:BC BARGE FLASHING & CAPPINGCOL STEEL COLUMNDP DOWNPIPE - COLOUR TO MATCH

ADJACENT WALL COLOUREXH EXHAUST DUCTFCL FINISHED CEILING LEVELFFL FINISHED FLOOR LEVELG SWINGING GATEGAS EXTERNAL GAS OUTLETIHW INSTANTANEOUS HOT WATERMB ELECTRICAL METERBOARDNGL NATURAL GROUND LINEOP OVERFLOW POPPC PARAPET CAPPINGRL RELATIVE LEVELRWT RAINWATER TANKRWH RAINWATER HEADSHR SHOWERSP SPREADER

NOTESN1:NCC 2014 BCA VOL 2ALL MATERIALS AND WORK PRACTICES SHALL COMPLYWITH, BUT NOT LIMITED TO THE BUILDING REGULATIONS2006, NATIONAL CONSTRUCTION CODE SERIES 2014BUILDING CODE OF AUSTRALIA VOL 2 AND ALL RELEVANTCURRENT AUSTRALIAN STANDARDS (AS AMENDED)REFERRED TO THEREIN. UNLESS OTHERWISE SPECIFIED,THE TERM NCC SHALL REFER TO NATIONALCONSTRUCTION CODE SERIES 2014 BUILDING CODE OFAUSTRALIA VOLUME 2.ALL MATERIALS AND CONSTRUCTION PRACTICE SHALLMEET THE PERFORMANCE REQUIREMENTS OF THE BCA.WHERE AN ALTERNATIVE SOLUTION IS PROPOSED THEN,PRIOR TO IMPLEMENTATION OR INSTALLATION, IT FIRSTMUST BE ASSESSED AND APPROVED BY THE RELEVANTBUILDING SURVEYOR AS MEETING THE PERFORMANCEREQUIREMENTS OF THE NCC.N2:GLAZING, INCLUDING SAFETY GLAZING, SHALL BEINSTALLED TO A SIZE, TYPE AND THICKNESS SO AS TOCOMPLY WITH:- BCA PART 3 FOR CLASS 1 AND 10BUILDINGS WITHIN A DESIGN WIND SPEED OF NOT MORETHAN N3; AND - NCC 2014 BCA VOL 1 PART B1.4 FORCLASS 2 AND 9 BUILDINGS.N3:THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHANY HOUSE ENERGY RATING (HERS) REPORT AND SHALLBE CONSTRUCTED IN ACCORDANCE WITH THE STAMPEDPLANS ENDORSED BY THE ACCREDITED THERMALPERFORMANCE ASSESSOR WITHOUT ALTERATIONN4:WHERE REQUIRED TREAT AREA BENEATH FLOOR AGAINSTTERMITE INFESTATION IN ACCORDANCE WITH RELEVANTSTANDARD. CONTACT THE RELEVANT MUNICIPAL COUNCILTO DETERMINE IF THIS IS MANDATORYN5:REFER SCHEDULES FOR DIMENSIONED DOOR & WINDOWELEVATIONS. WINDOW SIZES NOMINATED ARE NOMINALONLY. ACTUAL SIZES MAY VARY ACCORDING TOMANUFACTURERN6:STEPS TO DECK AS REQUIRED. 190MM MAX. RISER.250MM MIN. GOING TREADS

W6

NORTH ELEVATION1:100E/3

EAST ELEVATION1:100E/4

BUILDINGENVELOPE LINE

BARGEFLASHING

POWDERCOAT ALUMINIUMWINDOWS. BUTT GLAZEDCORNER WINDOW

N.G.L.

SPOTTED GUM TIMBER SCREEN.90MM X 32MM. 64MM GAPS.90X32MM BOTTOM PLATE FIXEDTO STEEL SADDLE PLATES150MM ABOVE CONCRETEFOOTING.

DOUBLEBRICK.RENDEREDFINISH

N.G.L.

FASCIAGUTTER

COLORBONDROOFSHEETING

RIDGECAPPING

50MMRENDEREDFOAM

BUILDINGENVELOPE LINE

50MMRENDEREDFOAM

BARGEFLASHING

BUILDINGENVELOPE LINE

POWDERCOATALUMINIUMSLIDING DOORS

POWDERCOATALUMINIUMWINDOWS

COLORBONDCORRUGATEDMETAL SHEETCLADDING

FASCIAGUTTER

FASCIAGUTTER

BRICKWORK

COLORBONDCORRUGATEDMETAL SHEET

CLADDING

COLORBONDCORRUGATEDMETAL SHEET

CLADDING

BRICKWORK

COLORBONDCORRUGATEDMETAL SHEETCLADDING

HOT WATERSERVICE TAPELECTRICAL

METERBOARDTELSTRAGASMETER

SOLARPANELS

600X600MMACCESSHATCH.

BLUEBOARD

COLORBONDCORRUGATEDMETAL SHEETCLADDING

EVAPCOOLER

CONFIRM EXTERNALEXPOSED AGG. SLAB

RL'S ON SITE.

1:100 @ A3

SIT

E B

OU

ND

AR

Y

SIT

E B

OU

ND

AR

Y

SIT

E B

OU

ND

AR

Y

NOTE: TIMBER SCREEN NOT SHOWN FOR CLARITY

Revisions:A W11 POSITION MOVED 15.12.15

A

Page 8: CONSTRUCTION - Derbyshire · as 3740 - waterproofing of wet areas in residential buildings as 3959 - construction in a bushfire prone area as 3786 - smoke alarms as 4055 - wind loadings

Project No:

Drawn:

Date:

Revision:

Scale:

Drawing No:

Drawing:Project:

Torquay, VIC., 3228

REFLECTED CEILINGPLAN

14-66 15/12/2015

BA - A05 of 20

98 Pakington Street, Geelong West, Vic., 3218

T 5221 8409 F 5229 7433

[email protected]

www.derbyshire.com.au

ABN 80 060 577 648

Revisions:- - -

DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes

CONSTRUCTION

M.H

.

1,220905,8351203,590902,020903,420902,120902,63090

11020,185

1,9202,0591,8561,0821,8561,9828991,0507101,7228398991,8611,200360

1,200110

10,620240

1,070

1,9201,300

3,6142,662

899576

1,22090

4,230120

1,53090

4,65090

1,220

90 500230

6,080 90 3,620 90 1,800 90 7,315 90 1,220

7,140 1,153 1,722 3,384 1,856 2,839 2,050

2404,260

90

2,2504,590

1,5306,630

2,35090

1,820

6,990 150 12,765 240 1,070

920901,62090

2,710901,190610902,9109062090

1002,4263,1432,432

2,43290

100

7,370 20,145 5,485

2,38010,970

1,650

5,61520,2957,090

2306,170

230

906,300

240

2302,375

901,895

S/2A09

S/4A11

S/3A10

S/1A08

MATERIALS & FINISHES SCHEDULE

MR MOISTURE RESISTANT PLASTERBOARDPB PLASTERBOARD. PAINT FINISHPB3 RAKED PLASTERBOARD CEILING. PAINT FINISH.PB4 INTERNAL PLASTERBOARD BULKHEADVB1 SOFFIT LINING SHEETING

REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH

ABBREVIATIONS:B BULKHEADCH CEILING HEIGHT FROM FINISHED FLOOR LEVELEXH EXHAUST DUCT AS SPEC.FCL FINISHED CEILING LEVELRL RELATIVE LEVEL

XX MATERIAL

NOTESN1:ALL CEILING AREAS TO BE SQUARE SET UNLESS NOTEDOTHERWISEN2:ALL BULKHEADS TO BE SQUARE SET TO CEILING PLANESN3:ALL CEILING HEIGHTS AS NOMINATED ON PLANSN4:REFER TO ELECTRICAL PLANS FOR LIGHTINGINFORMATION

1:100 @ A3

GARAGE

PLASTERBOARDCEILING 2700MM HIGH

COVED CORNICE

BED 2

BED 3MASTER BED BATHWIRENS LIVING

DININGKITCHENL'DRY

ENTRY

RO

BE

PASSAGE

FLUSH PLASTERBOARDCEILING 2700MM HIGHSQUARE SET CORNICE

FLUSH PLASTERBOARDCEILING 2700MM HIGHSQUARE SET CORNICE

FLUSH PLASTERBOARDCEILING 2700MM HIGHSQUARE SET CORNICE

2400

MM

HIG

HC

OV

ED

CO

RN

ICE

2400MM HIGHCOVED CORNICE

MR PLASTER2700MM HIGH

FLUSH PLASTERBOARDCEILING 2700MM HIGHSQUARE SET CORNICE

MR PLASTER2700MM HIGH

FLUSH PLASTERBOARDCEILING 2700MM HIGHSQUARE SET CORNICE

FLUSH PLASTERBOARDCEILING 2700MM HIGHSQUARE SET CORNICE

MRPLASTER2700MM

HIGH

RAKED P'BOARDCEILING

SQUARE SET CORNICE

FLUSH PLASTERBOARDCEILING 2700MM HIGHSQUARE SET CORNICE

FAL

L10

DE

G.

(ROOF SOFFIT LINE)

RO

OF

SO

FF

IT L

INE FA

LL

10 D

EG

.FA

LL

10 D

EG

.

RA

KE

D 4

.5M

MH

AR

DIF

LEX

WIT

HE

XP

RE

SS

ED

JO

INT

S

FAL

L10

DE

G.

RAKED 4.5MM HARDIFLEXWITH EXPRESSED JOINTS

RA

KE

D 4

.5M

MH

AR

DIF

LEX

WIT

HE

XP

RE

SS

ED

JO

INT

S

RO

OF

SO

FF

IT L

INE

ROOF SOFFIT LINE

4.5MM HARDIEFLEX

4.5M

M H

AR

DIE

FLE

X BULKHEAD

BU

LKH

EA

D

BU

LKH

EA

D

FAL

L10

DE

G.

BU

LKH

EA

D

VILLABOARDTO WALLS

VILLABOARDTO WALLS

VILLABOARDTO WALLS

RA

KE

D 4

.5M

MH

AR

DIF

LEX

WIT

HE

XP

RE

SS

ED

JO

INT

S

Page 9: CONSTRUCTION - Derbyshire · as 3740 - waterproofing of wet areas in residential buildings as 3959 - construction in a bushfire prone area as 3786 - smoke alarms as 4055 - wind loadings

Project No:

Drawn:

Date:

Revision:

Scale:

Drawing No:

Drawing:Project:

Torquay, VIC., 3228

ELECTRICAL PLAN14-66 15/12/2015

BA - A06 of 20

98 Pakington Street, Geelong West, Vic., 3218

T 5221 8409 F 5229 7433

[email protected]

www.derbyshire.com.au

ABN 80 060 577 648

Revisions:- - -

DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes

CONSTRUCTION

D

F

W

DW

D

F

1

2

W

22

44

22

22

22

11

11

11

22

1 2

2

2

2

2

2

22

SD

SD

EF

EF

M.H

.

2

2

EC

EC

EC

EC

EC

EC

EC

DH

DH

DH

DH

DH

DH

DH

DH

M

PL1

FF

TL

PL2

PL2

TL

PL3

PL3

1,220905,8351203,590902,020903,420902,120902,63090

11020,185

1,9202,0591,8561,0821,8561,9828991,0507101,7228398991,8611,200360

1,200110

10,620240

1,070

1,9201,300

3,6142,662

899576

1,22090

4,230120

1,53090

4,65090

1,220

90 500230

6,080 90 3,620 90 1,800 90 7,315 90 1,220

7,140 1,153 1,722 3,384 1,856 2,839 2,050

2404,260

90

2,2504,590

1,5306,630

2,35090

1,820

6,990 150 12,765 240 1,070

920901,62090

2,710901,190610902,9109062090

1002,4263,1432,432

2,43290

100

7,370 20,145 5,485

2,38010,970

1,650

5,61520,2957,090

2306,170

230

906,300

240

2302,375

901,895

FO

XT

V

PH

TV

TV

E2

DL

ED

LE

DL

ED

L

ED

L DL

DL

DL

DL

DL

DL

DL

DL

DL

DL

DL

DL

DL

DL

DL

DL

DL

DL

DL

DL

DL

DL

ED

L

ED

LE

DL

ED

LE

DL

ED

L

ED

L

ED

L

ED

L

DL

DL

DL

DL

DL

DL

DL

DL

ED

LE

DL

FL

FL

DL

DL

ELECTRICAL LEGEND GF2D

DH

DL

EC

EDL

EF

FL

1

2

E2

4

M

TL

ID1G

2G

3G

4G

D

DH

DL

EC

EDL

EF

F

FL

FOX

GPO1

GPO2

GPO2E

GPO4

MS

PH

PL1

PL2

PL3

SD

TL

TV

ITEM1 GANG SWITCH

2 GANG SWITCH

3 GANG SWITCH

4 GANG SWITCH

DATA POINT - CAT6

DUCTED HEATING POINT

LED DOWNLIGHT

EVAP COOLING POINT

EXTERNAL LED DOWNLIGHT

CEILING EXHAUST FAN

FLUORESCENT

FLOOD LIGHT WITH SENSOR

FOXTEL POINT

SINGLE GPO

DOUBLE GPO

DOUBLE GPO EXTERNAL

FOUR GPO

MOTION SENSOR

PHONE POINT

ENTRY PENDANT LIGHT

DINING PENDANT LIGHT. CLIENTSUPPLY.

PENDANT LIGHT

SMOKE DETECTOR

TASTIC LIGHT

TELEVISION POINT

No.5

3

2

4

2

8

33

7

15

2

2

2

1

8

21

1

2

1

1

1

2

2

2

2

3

NOTESN1:PROVIDE POWER FOR:KITCHEN- DISHWASHER- OVEN- RANGEHOOD- REFRIGERATOR- COOKTOPN2:ALL LIGHT FITTINGS & LAMPS SHOWN ARE ENERGYEFFICIENT. ANY CHANGE TO NUMBER OF OR LAMPENERGY OUTPUT MUST BE RE-EVALUATED FOR OVERALLCOMPLIANCE OF NCC/BCA PART 3.12.5.4.N3:ALL INTERNAL LIGHTS ARE SURFACE MOUNTED UNLESSOTHERWISE NOTED. NOTE: THE R VALUE OF THE CEILINGINSULATION MUST BE INCREASED WHERE CEILINGINSULATION IS REMOVED AROUND DOWN LIGHTS ANDEXHAUST FANS AS PER THE BCA TABLE 3.12.1.1A.N4:ALL FOR INDUSTRY APPROVED DOWNLIGHT COVERS FORINSULATION PROTECTION AND DRAFT SEALING(EXAMPLE: IGLOO RECESSED DOWNLIGHT COVER)N5:ALL EXTERNAL LIGHT FITTINGS ARE TO BE MARINE GRADEAND BE CONTROLLED BY DAYLIGHT MOTION SENSORS.N6:SMOKE ALARMS TO BE PROVIDED AND INSTALLED INACCORDANCE WITH AS3786. NEW DWELLINGS ANDADDITIONS WITH SLEEPING ACCOMMODATION TO BEHARD WIRED WITH BATTERY BACK UP.

ABBREVIATIONS:1050 DENOTES HEIGHT TO CENTRELINE OF GPO

FROM FFL2W 2 WAY LIGHT SWITCHA ARCHITRAVE MOUNTED LIGHT SWITCHD DIMMABLE SWITCH

WIRING

1:100, 1:1 @ A3

WATTAGETOTAL WATTAGE - 1,039 W

WATTAGE PER M2 - DESIGN AVERAGE INTERNAL 4.08 W/M2 (747W/182.66M2), VERANDAH OR BALCONY 4.0 W/M2(180W/44.75M2) & GARAGE 2.9 W/M2 (112W/38.304M2).

ALLOWABLE WATTAGE - INTERNAL 5W/M2, VERANDAH ORBALCONY 4W/M2 & GARAGE 3.0W/M2).

GARAGE BED 2

BED 3MASTER BED BATHWIRENS LIVING

DININGKITCHENL'DRY

ENTRY PASSAGE

M/BGAS T

2W

2W

2W

2W

2W

2W

2W

2W

CONDUIT INSLABDUCTED

HEATINGUNTIT

Page 10: CONSTRUCTION - Derbyshire · as 3740 - waterproofing of wet areas in residential buildings as 3959 - construction in a bushfire prone area as 3786 - smoke alarms as 4055 - wind loadings

Project No:

Drawn:

Date:

Revision:

Scale:

Drawing No:

Drawing:Project:

Torquay, VIC., 3228

ROOF PLAN14-66 15/12/2015

BA - A07 of 20

98 Pakington Street, Geelong West, Vic., 3218

T 5221 8409 F 5229 7433

[email protected]

www.derbyshire.com.au

ABN 80 060 577 648

Revisions:- - -

DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes

CONSTRUCTION

E/3A04

E/4A04

E/1A03

E/2A03 S/2

A09

S/4A11

S/3A10

S/1A08

NOTESN1:THE LOCATION OF ALL ROOF EQUIPMENT TO BE VERIFIEDON SITE PRIOR TO INSTALLATIONN2:CONNECT DOWNPIPES TO RAINWATER TANK.STORMWATER OVERFLOW TO BE TAKEN TO THE LEGALPOINT OF DISCHARGE TO THE RELEVANT AUTHORITIESAPPROVAL.N3:INSTALL ALL FLASHINGS AND CAPPING'S AS NECESSARYTO ENSURE COMPLETE ROOF WATER TIGHTNESS.N4:REFER TO INTRAX ENGINEERS DOCUMENTATION FORCOMPLETE STORMWATER DESIGNN5:DEKTITE FLASHING TO ROOF PENETRATIONSN6:BOX GUTTER SIZE 400MM X 100MM DEEP MINIMUM.INTRAX TO CHECK & CONFIRM. 1:100 FALL MIN.N7:COLORBOND PARAPET CAPPING TO FALL INWARDS. ONSLOPING HW BATTEN FIZED TO TOP OF WALL STRUCTURE

MATERIALS & FINISHES SCHEDULE

CB COLORBOND CORRUGATED ROOFING

REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH

ABBREVIATIONS:AER ROOF ANTENNABC BARGE FLASHING & CAPPINGBG BOX GUTTERCC COLORBOND CAPPINGDP DOWNPIPEFC FASCIA CAPPINGFG FASCIA GUTTERFWB FEATURE WINDOW BOXING - ALUMINIUMGSP 250X250MM GRATED S.W. PITSOP OVERFLOW POPPC PARAPET CAPPINGRL RELATIVE LEVELSG SOAKER GUTTERSPR SPREADERRWH RAIN WATER HEADWRF WALL / ROOF FLASHING

XX MATERIAL

FG

CB BC

RC

CB

FG

CB

BC

FG

CB

RC

CB

FG

CB

FG

RC

PC

BC

BC

BGBC

BC

PC

WRFWRFPC

FG

FG

BC

WRF

COLORBOND FLAT SHEET OVER PLY. FALL TOWALL. FORM GUTTER OUT OF SHEET & FALLTO DP.

1:100 @ A3

FAL

L10

º

(WALL BELOW)

(WA

LL B

ELO

W)

(WALL BELOW)

RWHDP &OP

(SITE BOUNDARY)

FAL

L10

º

DP

DP DP

DPDPDP

(WALL BELOW)

FAL

L1.

FAL

L10

ºFA

LL

10º

FAL

L10

º

(GARAGE WALL BELOW)

(WALL BELOW)

CHECKSOLAR HWS OR RAINWATER TANK

RO

OF

ST

EP

SOLAR PANELS

GSP

GSP GSP

GSP

LPOD TO KERB.REFER COGG

DETAILS

EVAPCOOLER

Page 11: CONSTRUCTION - Derbyshire · as 3740 - waterproofing of wet areas in residential buildings as 3959 - construction in a bushfire prone area as 3786 - smoke alarms as 4055 - wind loadings

Project No:

Drawn:

Date:

Revision:

Scale:

Drawing No:

Drawing:Project:

Torquay, VIC., 3228

SECTION 114-66 15/12/2015

BA - A08 of 20

98 Pakington Street, Geelong West, Vic., 3218

T 5221 8409 F 5229 7433

[email protected]

www.derbyshire.com.au

ABN 80 060 577 648

Revisions:- - -

DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes

CONSTRUCTION

3,10

0

2,70

040

0

2,70

01,

480

4,18

0

2,70

0

RD2

D4

R.L. 100.40

R.L. 100.25

R.L. 102.95

R.L. 105.08

R.L. 100.40

R.L. 103.10

MATERIALS & FINISHES SCHEDULE:CA1 CARPETCB COLORBOND SHEET ROOFINGCC COVED CORNICECOS CONCRETE SLABMDF PAINTED MDFMR MOISTURE RESISTANT PLASTERBOARDPB PLASTERBOARD PAINT FINISHSK1 TIMBER SKIRTINGTD TIMBER DECKINGVB1 SOFFIT LINING SHEETING

REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH

ABBREVIATIONS:B BULKHEADBC BARGE FLASHING & CAPPINGCOL STEEL COLUMNDP DOWNPIPEEXH EXHAUST DUCTFCL FINISHED CEILING LEVELFFL FINISHED FLOOR LEVELG SWINGING GATEGAS EXTERNAL GAS OUTLETIHW INSTANTANEOUS HOT WATERMB ELECTRICAL METERBOARDNGL NATURAL GROUND LINEOP OVERFLOW POPPC PARAPET CAPPINGRL RELATIVE LEVELRWT RAINWATER TANKRWH RAINWATER HEADSHR SHOWERSP SPREADER

NOTESN1:THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANYSTRUCTURAL OR CIVIL ENGINEERING COMPUTATIONSAND DRAWINGS; AND ALL OTHER CONSULTANTSDRAWINGS / DETAILS AND WITH ANY OTHER WRITTENINSTRUCTIONS ISSUED IN THE COURSE OF THECONTRACT.N2:GLAZING, INCLUDING SAFETY GLAZING, SHALL BEINSTALLED TO A SIZE, TYPE AND THICKNESS SO AS TOCOMPLY WITH:- BCA PART 3 FOR CLASS 1 AND 10BUILDINGS WITHIN A DESIGN WIND SPEED OF NOT MORETHAN N3; AND - NCC 2014 BCA VOL 1 PART B1.4 FORCLASS 2 AND 9 BUILDINGS.N3:THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHANY HOUSE ENERGY RATING (HERS) REPORT AND SHALLBE CONSTRUCTED IN ACCORDANCE WITH THE STAMPEDPLANS ENDORSED BY THE ACCREDITED THERMALPERFORMANCE ASSESSOR WITHOUT ALTERATIONN4:WHERE REQUIRED TREAT AREA BENEATH FLOOR AGAINSTTERMITE INFESTATION IN ACCORDANCE WITH RELEVANTSTANDARD. CONTACT THE RELEVANT MUNICIPAL COUNCILTO DETERMINE IF THIS IS MANDATORYN5:REFER TO SCHEDULES FOR DIMENSIONED DOOR &WINDOW ELEVATIONS. WINDOW SIZES NOMINATED ARENOMINAL ONLY. ACTUAL SIZES MAY VARY ACCORDING TOMANUFACTURERN6:STEPS TO DECK. 190MM MAX. RISER. 250MM MIN. GOINGTREADSN8:REFER TO STRUCTURAL ENGINEERING DOCUMENTS FORFOOTINGS & SLAB SPECIFICATION, FLOOR & WALLFRAMING.N9:REFER TO ENERGY REPORT FOR NOMINATION OF ALLINSULATION.

SECTION 11:50S/1

CONCRETE

COVED CORNICETO GARAGE

10MM FLUSH P'BOARD TO U/SOF 70X25MM MPG10 BATTENOR MPG10 TOPHAT BATTENSAT 450CTS MAX. FRAME OUT

CEILING AS REQUIRED TOACHIEVE 2700MM HEIGHT.

COLORBOND WALL /ROOF FLASHING

PROVIDE INSULATIONTO EXTERNAL WALLS

AS PERSPECIFICATIONS

COLORBOND PARAPETCAPPING TO FALL

INWARDS ON SLOPINGH.W. BATTEN FIXED TO

TOP OF WALL STRUCTURE

PROVIDE 300MM W x 150MM DCOLORBOND BOX GUTTER @1:100MM FALL ON SPANDECKGUTTER SUPPORT SYSTEM

COLORBONDROOF SHEETING ASSPECIFIED

SLAB & CONCRETEFOOTINGS TO STRUCTURALENGINEERS DETAILS

10MMPLASTERBOARDWALL LINING TO90MM STUD WALL

SELECTEDSKIRTING

COLORBOND ROOFSHEETING, SARKING ANDFLASHING AS REQUIRED TORENDER ROOF WATERTIGHT

INSULATION BATTS TOROOF AS PERSPECIFICATION

FASCIAGUTTER

CARPET

COLORBONDCORRUGATED METAL

SHEET CLADDING

SELECTEDARCHITRAVES

RAKEDPLASTERBOARDCEILING

PREFABRICATED ROOFTRUSS @ 600MM CENTRESAS PER MANUFACTURERSSPECIFICATIONS

RAKED 4.5MMHARDIEFLEX

CEMENT SHEET

BRICKWORK

NGL

BARGE CAPPING

BRICKWORK

POWDERCOATALUMINIUMWINDOWS

BUILDINGENVELOPE LINE

BUILDINGENVELOPE LINE

PREFABRICATED ROOFTRUSS @ 600MM CENTRESAS PER MANUFACTURERSSPECIFICATIONS

1:50 @ A3

FALL 1.5 DEG.

GARAGE6MM VILLABOARD TOGARAGE

FALL 10 DEG.

ENTRY WIR

SIT

E B

OU

ND

AR

Y

SIT

E B

OU

ND

AR

Y

Page 12: CONSTRUCTION - Derbyshire · as 3740 - waterproofing of wet areas in residential buildings as 3959 - construction in a bushfire prone area as 3786 - smoke alarms as 4055 - wind loadings

Project No:

Drawn:

Date:

Revision:

Scale:

Drawing No:

Drawing:Project:

Torquay, VIC., 3228

SECTION 214-66 15/12/2015

BA - A09 of 20

98 Pakington Street, Geelong West, Vic., 3218

T 5221 8409 F 5229 7433

[email protected]

www.derbyshire.com.au

ABN 80 060 577 648

Revisions:- - -

DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes

CONSTRUCTION

2,70

01,

200

3,90

0

2,10

060

0

2,70

0

D7W4

R.L. 100.40

R.L. 103.1

R.L. 104.3

MATERIALS & FINISHES SCHEDULE:CA1 CARPETCB COLORBOND SHEET ROOFINGCC COVED CORNICECOS CONCRETE SLABMDF PAINTED MDFMR MOISTURE RESISTANT PLASTERBOARDPB PLASTERBOARD PAINT FINISHSK1 TIMBER SKIRTINGTD TIMBER DECKINGVB1 SOFFIT LINING SHEETING

REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH

ABBREVIATIONS:B BULKHEADBC BARGE FLASHING & CAPPINGCOL STEEL COLUMNDP DOWNPIPEEXH EXHAUST DUCTFCL FINISHED CEILING LEVELFFL FINISHED FLOOR LEVELG SWINGING GATEGAS EXTERNAL GAS OUTLETIHW INSTANTANEOUS HOT WATERMB ELECTRICAL METERBOARDNGL NATURAL GROUND LINEOP OVERFLOW POPPC PARAPET CAPPINGRL RELATIVE LEVELRWT RAINWATER TANKRWH RAINWATER HEADSHR SHOWERSP SPREADER

NOTESN1:THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANYSTRUCTURAL OR CIVIL ENGINEERING COMPUTATIONSAND DRAWINGS; AND ALL OTHER CONSULTANTSDRAWINGS / DETAILS AND WITH ANY OTHER WRITTENINSTRUCTIONS ISSUED IN THE COURSE OF THECONTRACT.N2:GLAZING, INCLUDING SAFETY GLAZING, SHALL BEINSTALLED TO A SIZE, TYPE AND THICKNESS SO AS TOCOMPLY WITH:- BCA PART 3 FOR CLASS 1 AND 10BUILDINGS WITHIN A DESIGN WIND SPEED OF NOT MORETHAN N3; AND - NCC 2014 BCA VOL 1 PART B1.4 FORCLASS 2 AND 9 BUILDINGS.N3:THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHANY HOUSE ENERGY RATING (HERS) REPORT AND SHALLBE CONSTRUCTED IN ACCORDANCE WITH THE STAMPEDPLANS ENDORSED BY THE ACCREDITED THERMALPERFORMANCE ASSESSOR WITHOUT ALTERATIONN4:WHERE REQUIRED TREAT AREA BENEATH FLOOR AGAINSTTERMITE INFESTATION IN ACCORDANCE WITH RELEVANTSTANDARD. CONTACT THE RELEVANT MUNICIPAL COUNCILTO DETERMINE IF THIS IS MANDATORYN5:REFER TO SCHEDULES FOR DIMENSIONED DOOR &WINDOW ELEVATIONS. WINDOW SIZES NOMINATED ARENOMINAL ONLY. ACTUAL SIZES MAY VARY ACCORDING TOMANUFACTURERN6:STEPS TO DECK. 190MM MAX. RISER. 250MM MIN. GOINGTREADSN8:REFER TO STRUCTURAL ENGINEERING DOCUMENTS FORFOOTINGS & SLAB SPECIFICATION, FLOOR & WALLFRAMING.N9:REFER TO ENERGY REPORT FOR NOMINATION OF ALLINSULATION.

SECTION 21:50S/2

COLORBOND ROOFSHEETING, SARKING ANDFLASHING AS REQUIRED TORENDER ROOF WATERTIGHT

INSULATION BATTS TOROOF AS PER

SPECIFICATION

FASCIAGUTTER

PREFABRICATED ROOFTRUSS @ 600MM CENTRESAS PER MANUFACTURERSSPECIFICATIONS

COLORBONDCORRUGATED METALSHEET CLADDING

RIDGECAPPING

PROVIDE INSULATIONTO EXTERNAL WALLSAS PERSPECIFICATIONS

SLAB & CONCRETEFOOTINGS TO STRUCTURALENGINEERS DETAILS

NGL

FASCIAGUTTER

POWDERCOATALUMINIUM

WINDOWS

DOWNPIPE10MMPLASTERBOARDWALL LINING TO90MM STUD WALL

SELECTEDSKIRTING

FLUSHPLASTERBOARD

SELECTEDARCHITRAVES

FLUSH MOISTURERESISTANT

PLASTERBOARD

TILES

BUILDINGENVELOPE LINE

BUILDINGENVELOPE LINE

DOWNPIPE

COLORBONDCORRUGATEDMETAL SHEET

CLADDING

HOT WATER SERVICE

SOLAR PANELS

EXPOSEDAGGREGATE

CONCRETE

1:50 @ A3

BED 2 PASS. BATH

SIT

E B

OU

ND

AR

Y

SIT

E B

OU

ND

AR

Y

FALL 10 DEG. FALL 10 DEG.

Page 13: CONSTRUCTION - Derbyshire · as 3740 - waterproofing of wet areas in residential buildings as 3959 - construction in a bushfire prone area as 3786 - smoke alarms as 4055 - wind loadings

Project No:

Drawn:

Date:

Revision:

Scale:

Drawing No:

Drawing:Project:

Torquay, VIC., 3228

SECTION 314-66 15/12/2015

BA - A10 of 20

98 Pakington Street, Geelong West, Vic., 3218

T 5221 8409 F 5229 7433

[email protected]

www.derbyshire.com.au

ABN 80 060 577 648

Revisions:- - -

DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes

CONSTRUCTION

300

300

2,10

0

2,09

860

2

2,70

0

W6

R.L. 100.40

R.L. 103.1

R.L. 104.3

MATERIALS & FINISHES SCHEDULE:CA1 CARPETCB COLORBOND SHEET ROOFINGCC COVED CORNICECOS CONCRETE SLABMDF PAINTED MDFMR MOISTURE RESISTANT PLASTERBOARDPB PLASTERBOARD PAINT FINISHSK1 TIMBER SKIRTINGTD TIMBER DECKINGVB1 SOFFIT LINING SHEETING

REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH

ABBREVIATIONS:B BULKHEADBC BARGE FLASHING & CAPPINGCOL STEEL COLUMNDP DOWNPIPEEXH EXHAUST DUCTFCL FINISHED CEILING LEVELFFL FINISHED FLOOR LEVELG SWINGING GATEGAS EXTERNAL GAS OUTLETIHW INSTANTANEOUS HOT WATERMB ELECTRICAL METERBOARDNGL NATURAL GROUND LINEOP OVERFLOW POPPC PARAPET CAPPINGRL RELATIVE LEVELRWT RAINWATER TANKRWH RAINWATER HEADSHR SHOWERSP SPREADER

NOTESN1:THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANYSTRUCTURAL OR CIVIL ENGINEERING COMPUTATIONSAND DRAWINGS; AND ALL OTHER CONSULTANTSDRAWINGS / DETAILS AND WITH ANY OTHER WRITTENINSTRUCTIONS ISSUED IN THE COURSE OF THECONTRACT.N2:GLAZING, INCLUDING SAFETY GLAZING, SHALL BEINSTALLED TO A SIZE, TYPE AND THICKNESS SO AS TOCOMPLY WITH:- BCA PART 3 FOR CLASS 1 AND 10BUILDINGS WITHIN A DESIGN WIND SPEED OF NOT MORETHAN N3; AND - NCC 2014 BCA VOL 1 PART B1.4 FORCLASS 2 AND 9 BUILDINGS.N3:THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHANY HOUSE ENERGY RATING (HERS) REPORT AND SHALLBE CONSTRUCTED IN ACCORDANCE WITH THE STAMPEDPLANS ENDORSED BY THE ACCREDITED THERMALPERFORMANCE ASSESSOR WITHOUT ALTERATIONN4:WHERE REQUIRED TREAT AREA BENEATH FLOOR AGAINSTTERMITE INFESTATION IN ACCORDANCE WITH RELEVANTSTANDARD. CONTACT THE RELEVANT MUNICIPAL COUNCILTO DETERMINE IF THIS IS MANDATORYN5:REFER TO SCHEDULES FOR DIMENSIONED DOOR &WINDOW ELEVATIONS. WINDOW SIZES NOMINATED ARENOMINAL ONLY. ACTUAL SIZES MAY VARY ACCORDING TOMANUFACTURERN6:STEPS TO DECK. 190MM MAX. RISER. 250MM MIN. GOINGTREADSN8:REFER TO STRUCTURAL ENGINEERING DOCUMENTS FORFOOTINGS & SLAB SPECIFICATION, FLOOR & WALLFRAMING.N9:REFER TO ENERGY REPORT FOR NOMINATION OF ALLINSULATION.

SECTION 31:50S/3

COLORBOND ROOFSHEETING, SARKING ANDFLASHING AS REQUIRED TORENDER ROOF WATERTIGHT

INSULATION BATTS TOROOF AS PER

SPECIFICATION

FASCIAGUTTER

PREFABRICATED ROOFTRUSS @ 600MM CENTRESAS PER MANUFACTURERSSPECIFICATIONS

COLORBONDCORRUGATED METALSHEET CLADDING

RIDGECAPPING

PROVIDEINSULATION TO

EXTERNALWALLS AS PER

SPECIFICATIONS

SLAB & CONCRETEFOOTINGS TOSTRUCTURAL

ENGINEERS DETAILS

NGL

FASCIAGUTTER

POWDERCOATALUMINIUM WINDOWS

10MMPLASTERBOARDWALL LINING TO90MM STUD WALL

SELECTEDSKIRTING

FLUSHPLASTERBOARD

SELECTEDARCHITRAVES

BUILDINGENVELOPE LINE

BUILDINGENVELOPE LINE

BRICKWORK

EXPOSEDAGGREGATECONCRETE

EXPOSEDAGGREGATE

CONCRETE

4.5MM HARDIEFLEX

COLORBOND FLAT SHEET OVERPLY. FALL TO WALL. FORMGUTTER OUT OF SHEET & FALLTO DP.

CONFIRM EXISTINGGROUND LEVELS ONSITE FOR EXPOSEDAGGREGATE SLAB.

50MMRENDEREDFOAM

1:50 @ A3

DINING LIVING

SIT

E B

OU

ND

AR

Y

SIT

E B

OU

ND

AR

Y

Page 14: CONSTRUCTION - Derbyshire · as 3740 - waterproofing of wet areas in residential buildings as 3959 - construction in a bushfire prone area as 3786 - smoke alarms as 4055 - wind loadings

Project No:

Drawn:

Date:

Revision:

Scale:

Drawing No:

Drawing:Project:

Torquay, VIC., 3228

SECTION 4 SHT.114-66 15/12/2015

BA - A11 of 20

98 Pakington Street, Geelong West, Vic., 3218

T 5221 8409 F 5229 7433

[email protected]

www.derbyshire.com.au

ABN 80 060 577 648

Revisions:- - -

DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes

CONSTRUCTION

D5

W3

D7

D1 D4

R.L. 100.40

R.L. 103.1

R.L. 105.08

MATERIALS & FINISHES SCHEDULE:CA1 CARPETCB COLORBOND SHEET ROOFINGCC COVED CORNICECOS CONCRETE SLABMDF PAINTED MDFMR MOISTURE RESISTANT PLASTERBOARDPB PLASTERBOARD PAINT FINISHSK1 TIMBER SKIRTINGTD TIMBER DECKINGVB1 SOFFIT LINING SHEETING

REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH

ABBREVIATIONS:B BULKHEADBC BARGE FLASHING & CAPPINGCOL STEEL COLUMNDP DOWNPIPEEXH EXHAUST DUCTFCL FINISHED CEILING LEVELFFL FINISHED FLOOR LEVELG SWINGING GATEGAS EXTERNAL GAS OUTLETIHW INSTANTANEOUS HOT WATERMB ELECTRICAL METERBOARDNGL NATURAL GROUND LINEOP OVERFLOW POPPC PARAPET CAPPINGRL RELATIVE LEVELRWT RAINWATER TANKRWH RAINWATER HEADSHR SHOWERSP SPREADER

NOTESN1:THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANYSTRUCTURAL OR CIVIL ENGINEERING COMPUTATIONSAND DRAWINGS; AND ALL OTHER CONSULTANTSDRAWINGS / DETAILS AND WITH ANY OTHER WRITTENINSTRUCTIONS ISSUED IN THE COURSE OF THECONTRACT.N2:GLAZING, INCLUDING SAFETY GLAZING, SHALL BEINSTALLED TO A SIZE, TYPE AND THICKNESS SO AS TOCOMPLY WITH:- BCA PART 3 FOR CLASS 1 AND 10BUILDINGS WITHIN A DESIGN WIND SPEED OF NOT MORETHAN N3; AND - NCC 2014 BCA VOL 1 PART B1.4 FORCLASS 2 AND 9 BUILDINGS.N3:THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHANY HOUSE ENERGY RATING (HERS) REPORT AND SHALLBE CONSTRUCTED IN ACCORDANCE WITH THE STAMPEDPLANS ENDORSED BY THE ACCREDITED THERMALPERFORMANCE ASSESSOR WITHOUT ALTERATIONN4:WHERE REQUIRED TREAT AREA BENEATH FLOOR AGAINSTTERMITE INFESTATION IN ACCORDANCE WITH RELEVANTSTANDARD. CONTACT THE RELEVANT MUNICIPAL COUNCILTO DETERMINE IF THIS IS MANDATORYN5:REFER TO SCHEDULES FOR DIMENSIONED DOOR &WINDOW ELEVATIONS. WINDOW SIZES NOMINATED ARENOMINAL ONLY. ACTUAL SIZES MAY VARY ACCORDING TOMANUFACTURERN6:STEPS TO DECK. 190MM MAX. RISER. 250MM MIN. GOINGTREADSN8:REFER TO STRUCTURAL ENGINEERING DOCUMENTS FORFOOTINGS & SLAB SPECIFICATION, FLOOR & WALLFRAMING.N9:REFER TO ENERGY REPORT FOR NOMINATION OF ALLINSULATION.

SECTION 41:50S/4

COLORBOND ROOFSHEETING, SARKING ANDFLASHING AS REQUIRED TORENDER ROOF WATERTIGHT

INSULATION BATTS TOROOF AS PER

SPECIFICATION

PREFABRICATED ROOFTRUSS @ 600MM CENTRESAS PER MANUFACTURERSSPECIFICATIONS

SLAB & CONCRETEFOOTINGS TO STRUCTURALENGINEERS DETAILS

NGL

POWDERCOATALUMINIUM WINDOWS

SELECTEDSKIRTING

FLUSHPLASTERBOARD

SELECTEDARCHITRAVES

50MM RENDEREDFOAM

10MMPLASTERBOARDWALL LINING TO90MM STUD WALL

SPOTTED GUMTIMBER SCREEN AS

SELECTED.90MM X 32MM.

64MM GAPS.

TIMBER POST ASSELECTED

BARGE CAPPING

RAKED 4.5MMHARDIEFLEX

CEMENT SHEET

RIDGE CAPPING

EXPOSEDAGGREGATE

CONCRETE

1:50 @ A3

ENTRY PASSAGE

Page 15: CONSTRUCTION - Derbyshire · as 3740 - waterproofing of wet areas in residential buildings as 3959 - construction in a bushfire prone area as 3786 - smoke alarms as 4055 - wind loadings

Project No:

Drawn:

Date:

Revision:

Scale:

Drawing No:

Drawing:Project:

Torquay, VIC., 3228

SECTION 4 SHT.214-66 15/12/2015

BA - A12 of 20

98 Pakington Street, Geelong West, Vic., 3218

T 5221 8409 F 5229 7433

[email protected]

www.derbyshire.com.au

ABN 80 060 577 648

Revisions:- - -

DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes

CONSTRUCTION

W5D7

R.L. 100.40

R.L. 103.1

R.L. 104.3

MATERIALS & FINISHES SCHEDULE:CA1 CARPETCB COLORBOND SHEET ROOFINGCC COVED CORNICECOS CONCRETE SLABMDF PAINTED MDFMR MOISTURE RESISTANT PLASTERBOARDPB PLASTERBOARD PAINT FINISHSK1 TIMBER SKIRTINGTD TIMBER DECKINGVB1 SOFFIT LINING SHEETING

REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH

ABBREVIATIONS:B BULKHEADBC BARGE FLASHING & CAPPINGCOL STEEL COLUMNDP DOWNPIPEEXH EXHAUST DUCTFCL FINISHED CEILING LEVELFFL FINISHED FLOOR LEVELG SWINGING GATEGAS EXTERNAL GAS OUTLETIHW INSTANTANEOUS HOT WATERMB ELECTRICAL METERBOARDNGL NATURAL GROUND LINEOP OVERFLOW POPPC PARAPET CAPPINGRL RELATIVE LEVELRWT RAINWATER TANKRWH RAINWATER HEADSHR SHOWERSP SPREADER

NOTESN1:THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANYSTRUCTURAL OR CIVIL ENGINEERING COMPUTATIONSAND DRAWINGS; AND ALL OTHER CONSULTANTSDRAWINGS / DETAILS AND WITH ANY OTHER WRITTENINSTRUCTIONS ISSUED IN THE COURSE OF THECONTRACT.N2:GLAZING, INCLUDING SAFETY GLAZING, SHALL BEINSTALLED TO A SIZE, TYPE AND THICKNESS SO AS TOCOMPLY WITH:- BCA PART 3 FOR CLASS 1 AND 10BUILDINGS WITHIN A DESIGN WIND SPEED OF NOT MORETHAN N3; AND - NCC 2014 BCA VOL 1 PART B1.4 FORCLASS 2 AND 9 BUILDINGS.N3:THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHANY HOUSE ENERGY RATING (HERS) REPORT AND SHALLBE CONSTRUCTED IN ACCORDANCE WITH THE STAMPEDPLANS ENDORSED BY THE ACCREDITED THERMALPERFORMANCE ASSESSOR WITHOUT ALTERATIONN4:WHERE REQUIRED TREAT AREA BENEATH FLOOR AGAINSTTERMITE INFESTATION IN ACCORDANCE WITH RELEVANTSTANDARD. CONTACT THE RELEVANT MUNICIPAL COUNCILTO DETERMINE IF THIS IS MANDATORYN5:REFER TO SCHEDULES FOR DIMENSIONED DOOR &WINDOW ELEVATIONS. WINDOW SIZES NOMINATED ARENOMINAL ONLY. ACTUAL SIZES MAY VARY ACCORDING TOMANUFACTURERN6:STEPS TO DECK. 190MM MAX. RISER. 250MM MIN. GOINGTREADSN8:REFER TO STRUCTURAL ENGINEERING DOCUMENTS FORFOOTINGS & SLAB SPECIFICATION, FLOOR & WALLFRAMING.N9:REFER TO ENERGY REPORT FOR NOMINATION OF ALLINSULATION.

SECTION 41:50S/4

COLORBOND ROOFSHEETING, SARKING AND

FLASHING AS REQUIRED TORENDER ROOF WATERTIGHT

INSULATION BATTS TOROOF AS PERSPECIFICATION

PREFABRICATED ROOFTRUSS @ 600MM CENTRESAS PER MANUFACTURERS

SPECIFICATIONS

SLAB & CONCRETEFOOTINGS TO STRUCTURAL

ENGINEERS DETAILSNGL

POWDERCOATALUMINIUM WINDOWS

SELECTEDSKIRTING

FLUSHPLASTERBOARD

10MMPLASTERBOARDWALL LINING TO

90MM STUD WALL

SPOTTED GUMTIMBER SCREEN ASSELECTED.90MM X 32MM.64MM GAPS.

BARGE CAPPING

RAKED 4.5MMHARDIEFLEXCEMENT SHEET

RIDGE CAPPING

COLORBONDCORRUGATED METALSHEET CLADDING

1:50 @ A3

SIT

E B

OU

ND

AR

Y

KITCHENPASSAGE DINING

Page 16: CONSTRUCTION - Derbyshire · as 3740 - waterproofing of wet areas in residential buildings as 3959 - construction in a bushfire prone area as 3786 - smoke alarms as 4055 - wind loadings

Project No:

Drawn:

Date:

Revision:

Scale:

Drawing No:

Drawing:Project:

Torquay, VIC., 3228

DOOR SCHEDULE SHT.114-66 15/12/2015

BA - A13 of 20

98 Pakington Street, Geelong West, Vic., 3218

T 5221 8409 F 5229 7433

[email protected]

www.derbyshire.com.au

ABN 80 060 577 648

Revisions:- - -

DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes

CONSTRUCTION

MATERIALS & FINISHES SCHEDULE:MDF PAINTED MDF

REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH

ABBREVIATIONS:CSD CAVITY SLIDING DOORCG CLEAR GLAZINGF FIXED PANELOG OBSCURE GLAZINGSD SLIDING DOOR

NOTESN1:GLAZING, INCLUDING SAFETY GLAZING, SHALL BEINSTALLED TO A SIZE, TYPE AND THICKNESS SO AS TOCOMPLY WITH:- BCA PART 3 FOR CLASS 1 AND 10BUILDINGS WITHIN A DESIGN WIND SPEED OF NOT MORETHAN N3; AND - NCC 2014 BCA VOL 1 PART B1.4 FORCLASS 2 AND 9 BUILDINGS.SAFETY GLASS TO BE USED INTHE FOLLOWING CASES:I) ALL ROOMS – WITHIN 500mm VERTICAL OF THE FLOOR.II) BATHROOMS – WITHIN 2000mm OF THE FLOOR.III) LAUNDRY – WITHIN 1200mm VERTICAL FROM FLOORAND/OR WITHIN 300mm HORIZONTAL FROM ALL DOORS.IV) DOORWAY – WITHIN 300mm HORIZONTAL FROMDOORS.SHOWER SCREENS SHALL BE GRADE A SAFETY GLASS.N2:THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHANY HOUSE ENERGY RATING (HERS) REPORT AND SHALLBE CONSTRUCTED IN ACCORDANCE WITH THE STAMPEDPLANS ENDORSED BY THE ACCREDITED THERMALPERFORMANCE ASSESSOR WITHOUT ALTERATIONN3:DOOR SIZES NOMINATED ARE NOMINAL ONLY. ACTUALSIZES MAY VARY ACCORDING TO MANUFACTURERN4:W.C. DOORS TO TOILET PANS LOCATED WITHIN 1.2m OFTHE DOOR JAMB LIFT OFF HINGES MUST BE FITTED.OTHERWISE THE DOORS MUST SWING OUTWARDS.N5:ALL WINDOWS AND DOORS TO BE SITE MEASURED PRIORTO MANUFACTURER / ORDER.N6:ALL WINDOWS & DOORS TO BE IN ACCORDANCE WITHAS1288-2011N7:PROVIDE DOOR THRSHOLD TO ALL EXTERNAL DOORSN8:ALL DOORS & WINDOWS VIEWED FROM OUTSIDE UNLESSNOTED OTHERWISEN9:PROVIDE LOCKS TO ALL OPENABLE WINDOWS ANDEXTERNAL DOORSN10:ALLOW FOR WEATHER SEALS TO ALL EDGES OF OPENINGWINDOW SASHES AND DOORS.N11:HARDWARE & FURNITURE TO BE PURCHASED BY CLIENT.

ID D1 D2 D3 D4 D5

Location ENTRY LAUNDRY LIVING / DINING GARAGE / ENTRY BED 2

Height 2,650 2,340 2,100 2,340 2,400Width 1,400 820 3,614 1,320 820

Elevation

1,400

2,65

0

820

2,34

0

1,320

2,34

0

820

2,40

0

Orientation SOUTH WEST NORTH N/A N/A

Door Leaf Type SOLID ALUMINIUM & GLAZED ALUMINIUM & GLAZED HOLLOW-CORE HOLLOW-CORE

Frame Type ALUMINIUM ALUMINIUM ALUMINIUM H/DUTY CAVITY DOOR UNIT TIMBER

Frame Finish POWDERCOAT POWDERCOAT POWDERCOAT PAINT PAINT

Hardware AS SELECTED AS SELECTED AS SELECTED AS SELECTED AS SELECTED

Operation Type PIVOT SWINGING 2 SLIDING. 1 FIXED. CAVITY SLIDER SWINGING

Glazing N/A SINGLE GLAZED DOUBLE GLAZED N/A N/A

Extras THIN VERT. SPOTTED GUM. BOTH SIDES - - - -

Comments - WHITE TRANSLUCENT - - -

Door Schedule

ID D6 D7 D8 D9

Location BED 2 ROBE PASSAGE KITCHEN / LAUNDRY BED 3

Height 2,400 2,700 2,350 2,360Width 4,640 1,530 970 2,060

Elevation

4,640

2,40

0

970

2,35

0

2,060

2,36

0

Orientation N/A N/A N/A N/A

Door Leaf Type MDF DOORS PAINTED HOLLOW-CORE HOLLOW-CORE HOLLOW-CORE

Frame Type SLIDING ROBE DOOR UNIT H/DUTY CAVITY DOOR UNIT H/DUTY CAVITY DOOR UNIT H/DUTY CAVITY DOOR UNIT

Frame Finish AS SELECTED PAINT PAINT PAINT

Hardware AS SELECTED AS SELECTED AS SELECTED AS SELECTED

Operation Type SLIDING CAVITY SLIDER CAVITY SLIDER CAVITY SLIDER

Glazing N/A N/A N/A N/A

Extras - - - -

Comments - RECESSED CEILING TRACK - -

Door Schedule

1:50 @ A3

Page 17: CONSTRUCTION - Derbyshire · as 3740 - waterproofing of wet areas in residential buildings as 3959 - construction in a bushfire prone area as 3786 - smoke alarms as 4055 - wind loadings

Project No:

Drawn:

Date:

Revision:

Scale:

Drawing No:

Drawing:Project:

Torquay, VIC., 3228

DOOR SCHEDULE SHT.214-66 15/12/2015

BA - A14 of 20

98 Pakington Street, Geelong West, Vic., 3218

T 5221 8409 F 5229 7433

[email protected]

www.derbyshire.com.au

ABN 80 060 577 648

Revisions:- - -

DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes

CONSTRUCTION

MATERIALS & FINISHES SCHEDULE:MDF PAINTED MDF

REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH

ABBREVIATIONS:CSD CAVITY SLIDING DOORCG CLEAR GLAZINGF FIXED PANELOG OBSCURE GLAZINGSD SLIDING DOOR

NOTESN1:GLAZING, INCLUDING SAFETY GLAZING, SHALL BEINSTALLED TO A SIZE, TYPE AND THICKNESS SO AS TOCOMPLY WITH:- BCA PART 3 FOR CLASS 1 AND 10BUILDINGS WITHIN A DESIGN WIND SPEED OF NOT MORETHAN N3; AND - NCC 2014 BCA VOL 1 PART B1.4 FORCLASS 2 AND 9 BUILDINGS.SAFETY GLASS TO BE USED INTHE FOLLOWING CASES:I) ALL ROOMS – WITHIN 500mm VERTICAL OF THE FLOOR.II) BATHROOMS – WITHIN 2000mm OF THE FLOOR.III) LAUNDRY – WITHIN 1200mm VERTICAL FROM FLOORAND/OR WITHIN 300mm HORIZONTAL FROM ALL DOORS.IV) DOORWAY – WITHIN 300mm HORIZONTAL FROMDOORS.SHOWER SCREENS SHALL BE GRADE A SAFETY GLASS.N2:THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHANY HOUSE ENERGY RATING (HERS) REPORT AND SHALLBE CONSTRUCTED IN ACCORDANCE WITH THE STAMPEDPLANS ENDORSED BY THE ACCREDITED THERMALPERFORMANCE ASSESSOR WITHOUT ALTERATIONN3:DOOR SIZES NOMINATED ARE NOMINAL ONLY. ACTUALSIZES MAY VARY ACCORDING TO MANUFACTURERN4:W.C. DOORS TO TOILET PANS LOCATED WITHIN 1.2m OFTHE DOOR JAMB LIFT OFF HINGES MUST BE FITTED.OTHERWISE THE DOORS MUST SWING OUTWARDS.N5:ALL WINDOWS AND DOORS TO BE SITE MEASURED PRIORTO MANUFACTURER / ORDER.N6:ALL WINDOWS & DOORS TO BE IN ACCORDANCE WITHAS1288-2011N7:PROVIDE DOOR THRSHOLD TO ALL EXTERNAL DOORSN8:ALL DOORS & WINDOWS VIEWED FROM OUTSIDE UNLESSNOTED OTHERWISEN9:PROVIDE LOCKS TO ALL OPENABLE WINDOWS ANDEXTERNAL DOORSN10:ALLOW FOR WEATHER SEALS TO ALL EDGES OF OPENINGWINDOW SASHES AND DOORS.N11:HARDWARE & FURNITURE TO BE PURCHASED BY CLIENT.

ID D10 D11 D12 D13 D13A D14

Location BED 3 BED 3 ROBE BATHROOM MASTER BED MASTER BED WIR MASTER BED ENSUITE

Height 2,360 2,400 2,400 2,400 2,400 2,400Width 1,860 1,710 820 820 2,100 820

Elevation

2,36

0

1,860 1,710

2,40

0

820

2,40

0

820

2,40

0

2,100

2,40

0

820

2,40

0

Orientation N/A N/A N/A N/A N/A N/A

Door Leaf Type HOLLOW-CORE MDF DOORS PAINTED HOLLOW-CORE HOLLOW-CORE MIRROR DOORS HOLLOW-CORE

Frame Type H/DUTY CAVITY DOOR UNIT SLIDING ROBE DOOR UNIT TIMBER TIMBER SLIDING ROBE DOOR UNIT SLIDING ROBE DOOR UNIT

Frame Finish PAINT AS SELECTED PAINT PAINT AS SELECTED PAINT

Hardware AS SELECTED AS SELECTED AS SELECTED AS SELECTED AS SELECTED AS SELECTED

Operation Type CAVITY SLIDER SLIDING SWINGING SWINGING SLIDING CAVITY SLIDER

Glazing N/A N/A N/A N/A N/A N/A

Extras - - - - - -

Comments - - - - - -

Door Schedule

ID RD1 RD2

Location GARAGE GARAGE REAR

Height 2,400 2,400Width 5,400 1,200

Elevation

2,40

0

5,400

5,380

2,40

0

Orientation SOUTH NORTH

Door Leaf Type SECTIONAL LIFT DOOR. COLORBOND ROLLER DOOR. COLORBOND

Frame Type STEEL STEEL

Frame Finish GALVANISED / COLORBOND GALVANISED / COLORBOND

Hardware AS SELECTED AS SELECTED

Operation Type SECTIONAL LIFT ROLLER

Glazing N/A N/A

Extras - -

Comments - -

Door Schedule

1:50 @ A3

Page 18: CONSTRUCTION - Derbyshire · as 3740 - waterproofing of wet areas in residential buildings as 3959 - construction in a bushfire prone area as 3786 - smoke alarms as 4055 - wind loadings

Project No:

Drawn:

Date:

Revision:

Scale:

Drawing No:

Drawing:Project:

Torquay, VIC., 3228

WINDOW SCHEDULE SHT.1

14-66 15/12/2015

BA - A15 of 20

98 Pakington Street, Geelong West, Vic., 3218

T 5221 8409 F 5229 7433

[email protected]

www.derbyshire.com.au

ABN 80 060 577 648

Revisions:- - -

DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes

CONSTRUCTION

ABBREVIATIONS:CG CLEAR GLAZINGF FIXED PANELOG OBSCURE GLAZING

NOTESN1:GLAZING, INCLUDING SAFETY GLAZING, SHALL BEINSTALLED TO A SIZE, TYPE AND THICKNESS SO AS TOCOMPLY WITH:- BCA PART 3 FOR CLASS 1 AND 10BUILDINGS WITHIN A DESIGN WIND SPEED OF NOT MORETHAN N3; AND - NCC 2014 BCA VOL 1 PART B1.4 FORCLASS 2 AND 9 BUILDINGS.SAFETY GLASS TO BE USED INTHE FOLLOWING CASES:I) ALL ROOMS – WITHIN 500mm VERTICAL OF THE FLOOR.II) BATHROOMS – WITHIN 2000mm OF THE FLOOR.III) LAUNDRY – WITHIN 1200mm VERTICAL FROM FLOORAND/OR WITHIN 300mm HORIZONTAL FROM ALL DOORS.IV) DOORWAY – WITHIN 300mm HORIZONTAL FROMDOORS.N2:THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHANY HOUSE ENERGY RATING (HERS) REPORT AND SHALLBE CONSTRUCTED IN ACCORDANCE WITH THE STAMPEDPLANS ENDORSED BY THE ACCREDITED THERMALPERFORMANCE ASSESSOR WITHOUT ALTERATIONN3:DOOR SIZES NOMINATED ARE NOMINAL ONLY. ACTUALSIZES MAY VARY ACCORDING TO MANUFACTURERN4:ALL WINDOWS AND DOORS TO BE SITE MEASURED PRIORTO MANUFACTURER / ORDER.N5:ALL WINDOWS & DOORS TO BE IN ACCORDANCE WITHAS1288-2011N6:PROVIDE DOOR THRSHOLD TO ALL EXTERNAL DOORSN7:ALL DOORS & WINDOWS VIEWED FROM OUTSIDE UNLESSNOTED OTHERWISEN8:PROVIDE LOCKS TO ALL OPENABLE WINDOWS ANDEXTERNAL DOORSN9:ALLOW FOR WEATHER SEALS TO ALL EDGES OF OPENINGWINDOW SASHES AND DOORS.

ID W1 W2 W2A W3 W4Location MASTER BED ENSUITE MASTER BED ENSUITE MASTER BED ENSUITE ENTRY (OVER DOOR) BED 2Height 600 600 600 1,564 2,098Width 1,800 1,800 600 1,500 1,722Window sill height 1,050 1,050 1,050 2,700 0Window head height 1,650 1,650 1,650 4,264 2,098

2D Symbol1,800 1,800 600 1,500 1,722

Elevation

1,800

600

600

1,791

600

591

1,500

1,56

4

1,722

2,09

8

Orientation SOUTH SOUTH WEST SOUTH WESTAccessoriesFinish POWDERCOAT POWDERCOAT POWDERCOAT POWDERCOAT POWDERCOATFrame Type ALUMINIUM ALUMINIUM ALUMINIUM ALUMINIUM ALUMINIUMGlazing DBL. GLAZED SINGLE GLAZED SINGLE GLAZE DBL. GLAZED DBL. GLAZEDOperation Type SLIDING FIXED FIXED FIXED SLIDINGVision Panel Type WHITE TRANSLUCENT COLOURBACK GLASS. MONUMENT TINTED MONUMENT TINTED CLEAR CLEARManufacturerComments MITRED BUTT JOINT CORNER TO W2A

Window List

ID W5 W6 W7 W7A W8Location KITCHEN DINING LIVING LIVING ROOM LIVING ROOMHeight 600 2,098 600 600 600Width 1,856 899 1,800 1,800 1,856Window sill height 900 0 900 900 900Window head height 1,500 2,098 1,500 1,500 1,500

2D Symbol1,856 899 1,800 1,800 1,856

Elevation

1,856

600

899

2,09

8

600

1,800

600

1,800 1,856

600

Orientation WEST NORTH NORTH EAST EASTAccessoriesFinish POWDERCOAT POWDERCOAT POWDERCOAT POWDERCOAT POWDERCOATFrame Type ALUMINIUM ALUMINIUM ALUMINIUM ALUMINIUM ALUMINIUMGlazing DBL. GLAZED DBL. GLAZED SINGLE GLAZED SINGLE GLAZED DBL. GLAZEDOperation Type FIXED DBL. HUNG FIXED FIXED SLIDINGVision Panel Type CLEAR CLEAR CLEAR CLEAR CLEARManufacturerComments BUTT GLAZED CORNER BUTT GLAZED CORNER

Window List

1:50 @ A3

A

Revisions:A W1 WIDTH REVISED 02.11.15

W2/2A COLOUR REVISED

Page 19: CONSTRUCTION - Derbyshire · as 3740 - waterproofing of wet areas in residential buildings as 3959 - construction in a bushfire prone area as 3786 - smoke alarms as 4055 - wind loadings

Project No:

Drawn:

Date:

Revision:

Scale:

Drawing No:

Drawing:Project:

Torquay, VIC., 3228

WINDOW SCHEDULE SHT.2

14-66 15/12/2015

BA - A16 of 20

98 Pakington Street, Geelong West, Vic., 3218

T 5221 8409 F 5229 7433

[email protected]

www.derbyshire.com.au

ABN 80 060 577 648

Revisions:- - -

DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes

CONSTRUCTION

ABBREVIATIONS:CG CLEAR GLAZINGF FIXED PANELOG OBSCURE GLAZING

NOTESN1:GLAZING, INCLUDING SAFETY GLAZING, SHALL BEINSTALLED TO A SIZE, TYPE AND THICKNESS SO AS TOCOMPLY WITH:- BCA PART 3 FOR CLASS 1 AND 10BUILDINGS WITHIN A DESIGN WIND SPEED OF NOT MORETHAN N3; AND - NCC 2014 BCA VOL 1 PART B1.4 FORCLASS 2 AND 9 BUILDINGS.SAFETY GLASS TO BE USED INTHE FOLLOWING CASES:I) ALL ROOMS – WITHIN 500mm VERTICAL OF THE FLOOR.II) BATHROOMS – WITHIN 2000mm OF THE FLOOR.III) LAUNDRY – WITHIN 1200mm VERTICAL FROM FLOORAND/OR WITHIN 300mm HORIZONTAL FROM ALL DOORS.IV) DOORWAY – WITHIN 300mm HORIZONTAL FROMDOORS.N2:THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHANY HOUSE ENERGY RATING (HERS) REPORT AND SHALLBE CONSTRUCTED IN ACCORDANCE WITH THE STAMPEDPLANS ENDORSED BY THE ACCREDITED THERMALPERFORMANCE ASSESSOR WITHOUT ALTERATIONN3:DOOR SIZES NOMINATED ARE NOMINAL ONLY. ACTUALSIZES MAY VARY ACCORDING TO MANUFACTURERN4:ALL WINDOWS AND DOORS TO BE SITE MEASURED PRIORTO MANUFACTURER / ORDER.N5:ALL WINDOWS & DOORS TO BE IN ACCORDANCE WITHAS1288-2011N6:PROVIDE DOOR THRSHOLD TO ALL EXTERNAL DOORSN7:ALL DOORS & WINDOWS VIEWED FROM OUTSIDE UNLESSNOTED OTHERWISEN8:PROVIDE LOCKS TO ALL OPENABLE WINDOWS ANDEXTERNAL DOORSN9:ALLOW FOR WEATHER SEALS TO ALL EDGES OF OPENINGWINDOW SASHES AND DOORS.

ID W9 W10 W11 W12 W13Location BED 3 BATHROOM MASTER BED WIR MASTER BED ENSUITEHeight 600 2,098 2,098 2,098 600Width 1,856 899 1,722 899 1,200Window sill height 900 0 0 0 1,700Window head height 1,500 2,098 2,098 2,098 2,300

2D Symbol1,856 899 1,722 899

1,200

Elevation

1,856

600

899

2,09

8

1,722

2,09

8

899

2,09

8

1,200

600

Orientation EAST EAST EAST EAST EASTAccessoriesFinish POWDERCOAT POWDERCOAT POWDERCOAT POWDERCOAT POWDERCOATFrame Type ALUMINIUM ALUMINIUM ALUMINIUM ALUMINIUM ALUMINIUMGlazing DBL. GLAZED SINGLE GLAZED DBL. GLAZED DBL. GLAZED DBL. GLAZEDOperation Type SLIDING DBL. HUNG SLIDING FIXED SLIDINGVision Panel Type CLEAR WHITE TRANSLUCENT CLEAR WHITE TRANSLUCENT WHITE TRANSLUCENTManufacturerComments

Window List

1:50 @ A3

Page 20: CONSTRUCTION - Derbyshire · as 3740 - waterproofing of wet areas in residential buildings as 3959 - construction in a bushfire prone area as 3786 - smoke alarms as 4055 - wind loadings

Project No:

Drawn:

Date:

Revision:

Scale:

Drawing No:

Drawing:Project:

Torquay, VIC., 3228

PLAN DET. & INT. ELEV -MASTER BED ENS. & WIR

14-66 15/12/2015

BA - A17 of 20

98 Pakington Street, Geelong West, Vic., 3218

T 5221 8409 F 5229 7433

[email protected]

www.derbyshire.com.au

ABN 80 060 577 648

Revisions:- - -

DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes

CONSTRUCTION

IE 01

IE 02

IE 03

IE 04

IE 05

IE 06

IE 07

IE 08

900

1,20

0

2,10

060

0

300

560

401,

500

300

2,70

0

D14

900

1,75

050

045

0

2,10

060

0

2,70

0

300

560

40

900

150

600

1,05

0

2,70

0

W1

300

560

40

900

150

1,35

030

0

2,70

0

909101,72090

902,63090

9091080092099

902,63099

2,729 90

901,820

902,350

901,894

1,800566

90

904,260

90

902,350

901,210

61090

610 900 610 90

2,120 90

904,260

90

610 900 610 90

MATERIALS:CA1 CARPETCOS CONCRETE SLABFSS FRAMELESS SHOWER SCREENGMD GLOSS MELAMINE DOORSGS GLASS SPLASHBACKKI1 KICKER TYPE 1LA1 LAMINATE TYPE 1LB1 LAMINATED BENCHTOPMA1 WHITE MELAMINEMDF PAINTED MDFMS1 MIRROR SPLASHBACKPB PLASTERBOARD PAINT FINISHPB2 WET AREA PLASTERBOARD - VILLABOARDRS1 RECONSTITUTED STONESK TIMBER SKIRTINGTF TIMBER FLOORINGTL1 FLOOR TILETL2 WALL TILETSP TILE SPLASHBACK.TSK TILE SKIRTINGVW1 VINYL WRAP

REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH

ABBREVIATIONS:AS ADJUSTABLE SHELFBS BATH SPOUTCSD CAVITY SLIDING DOORCTB COUNTER TOP BASINDRW DRAWERDRY DRYERDW DISHWASHERFCL FINISHED CEILING LEVELFFL FINISHED FLOOR LEVELFS FIXED SHELFFW FLOOR WASTEGFS GLAZED FIXED SHELFGPO GENERAL PURPOSE OUTLETHR HANGING RAILHTR HAND TOWEL RAILLTR LAUNDRY TROUGHMH MANHOLEMI MIRRORMX MIXER TAPMW MICROWAVENOM NOMINAL LENGTHNS NOOK SHELFOS OPEN SHELFPL PENDANT LIGHTRA RETURN AIR DUCTREF REFRIGERATORS(U) SINK UNDERMOUNTSHR SHOWERSHH SHOWER HEADTR TOWEL RAIL (TR(H) - heated)TRH TOILET ROLL HOLDERTS TOILET SUITEWB WALL HUNG BASINWO WALL OVENWM WASHING MACHINE

NOTESN1:THE LOCATION OF SERVICES IS APPROXIMATE ONLY.BUILDER TO DETERMINE THE EXACT LOCATIONS OFSERVICES ON SITE PRIOR TO TENDERING.N2:DRAWINGS ARE TO BE READ IN CONJUNCTION WIITHJOINERY SCHEDULE IN SPECIFICATIONN3:CHECK & CONFIRM ALL DIMENSIONS ON SITE PRIOR TOMANUFACTURING / CONSTRUCTIONN4:UNLESS OTHERWISE NOTED, ALL INTERNAL CARCASSESTO BE WHITE MELAMINEN5:ALL WET AREAS TO COMPLY WITH AS 3740. WALL FINISHESSHALL BE IMPERVIOUS TO A HEIGHT OF 1800mm ABOVEFLOOR LEVEL TO SHOWER ENCLOSURES AND 300mmABOVE BATHS, BASINS, SINKS AND TROUGHS IF WITHIN75mm OF THE WALL. REFER TO CODE FOR ALLREQUIREMENTS.N6:W.C. DOORS TO TOILET PANS LOCATED WITHIN 1.2m OFTHE DOOR JAMB LIFT OFF HINGES MUST BE FITTED.OTHERWISE THE DOORS MUST SWING OUTWARDS.N7:SAFETY GLASS TO BE USED IN THE FOLLOWING CASES:I) ALL ROOMS – WITHIN 500mm VERTICAL OF THE FLOOR.II) BATHROOMS – WITHIN 2000mm OF THE FLOOR.III) LAUNDRY – WITHIN 1200mm VERTICAL FROM FLOORAND/OR WITHIN 300mm HORIZONTAL FROM ALL DOORS.IV) DOORWAY – WITHIN 300mm HORIZONTAL FROMDOORS.SHOWER SCREENS SHALL BE GRADE A SAFETY GLASS.

J0 JOINERY NO.

XX MATERIAL

W0 WINDOW NO.

D0 DOOR NO.

300

300

300

300

300

300

300

300

300

2,70

0

800

800

250

1,35

020

030

060

0

800

800

200

300

600

800

800

200

300

600

250

1,35

0

800

800

200

300

600

300

300

300

300

300

300

300

300

2,40

030

0

2,70

0

D14

900

1,50

0

2,40

0

300

300

300

300

300

300

300

300

D13A

PLAN DETAIL - ENS & WIR1:50

INT. ELEV. 01 - ENS1:50IE 01 INT. ELEV. 02 - ENS

1:50IE 02

INT. ELEV. 03 - ENS1:50IE 03 INT. ELEV. 04 - ENS

1:50IE 04

INT. ELEV. 05 - WIR1:50IE 05 INT. ELEV. 06 - WIR

1:50IE 06 INT. ELEV. 07 - WIR1:50IE 07 INT. ELEV. 08 - WIR

1:50IE 08

CAROMA CUBE1800MM BATH

TL1 TL1

TL1 TL1

CA1 CA1 CA1 CA1

TL2

TL2

TL2

TL2

PB2

PB2

PB2

W1

W2

W2A

W13 W12

D13A

D14

SEMI-FRAMELESSSHOWER SCREEN

FULL HEIGHT TILESTO THIS WALL ALSO

1:50 @ A3

TS

FS

FS FS

FS

FS

FSDRW

DRW

DRW

DRW

BN

MX

MI

TS

HR

HR

HR

HR

HR

HR

HR

HR

HRHR

FS

FS

DRW DRW

DRW DRW

DRW DRW

FS

FS

FS

FS

FS

FS

FS

FS

FS

FS

FS

FS

FS

FS

FS

FS

DRW

DRW

DRW

FS FS

FS

FSFSFS FS

FS

FS

FS

FS

FS

DRW

DRW

DRW

FRAMELESS

SHH

SHR

MX

SHH

SHR

MX

ENS.TILES

W.I.R.CARPET

FS FS

NS

FW

NS

TSBATH

TR TR

TRH

DRW DRW DRW DRW

FS FSFSFSFS

TRH

BATH

TR TR

TR

FS FS

BS MX

HTR

HTR

BS

(W2 BEHIND PLASTER)

(W2ABEHIND

PLASTER)

A

Revisions:A W1 WIDTH REVISED

W2 & W2A HIDDEN INTERNALLY 02.11.1502/11/2015

LA1

LA1

RS1

RS1

RS1

TSP

LA1

TSP

TSP

Page 21: CONSTRUCTION - Derbyshire · as 3740 - waterproofing of wet areas in residential buildings as 3959 - construction in a bushfire prone area as 3786 - smoke alarms as 4055 - wind loadings

Project No:

Drawn:

Date:

Revision:

Scale:

Drawing No:

Drawing:Project:

Torquay, VIC., 3228

PLAN DET. & INT. ELEV. -BATH & BED 3

14-66 15/12/2015

BA - A18 of 20

98 Pakington Street, Geelong West, Vic., 3218

T 5221 8409 F 5229 7433

[email protected]

www.derbyshire.com.au

ABN 80 060 577 648

Revisions:- - -

DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes

CONSTRUCTION

MATERIALS:CA1 CARPETCOS CONCRETE SLABFSS FRAMELESS SHOWER SCREENGMD GLOSS MELAMINE DOORSGS GLASS SPLASHBACKKI1 KICKER TYPE 1LA1 LAMINATE TYPE 1LB1 LAMINATED BENCHTOPMA1 WHITE MELAMINEMDF PAINTED MDFMS1 MIRROR SPLASHBACKPB PLASTERBOARD PAINT FINISHPB2 WET AREA PLASTERBOARD - VILLABOARDRS1 RECONSTITUTED STONESK TIMBER SKIRTINGTF TIMBER FLOORINGTL1 FLOOR TILETL2 WALL TILETSP TILE SPLASHBACK.TSK TILE SKIRTINGVW1 VINYL WRAP

REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH

ABBREVIATIONS:AS ADJUSTABLE SHELFBS BATH SPOUTCSD CAVITY SLIDING DOORCTB COUNTER TOP BASINDRW DRAWERDRY DRYERDW DISHWASHERFCL FINISHED CEILING LEVELFFL FINISHED FLOOR LEVELFS FIXED SHELFFW FLOOR WASTEGFS GLAZED FIXED SHELFGPO GENERAL PURPOSE OUTLETHR HANGING RAILHTR HAND TOWEL RAILLTR LAUNDRY TROUGHMH MANHOLEMI MIRRORMX MIXER TAPMW MICROWAVENOM NOMINAL LENGTHNS NOOK SHELFOS OPEN SHELFPL PENDANT LIGHTRA RETURN AIR DUCTREF REFRIGERATORS(U) SINK UNDERMOUNTSHR SHOWERSHH SHOWER HEADTR TOWEL RAIL (TR(H) - heated)TRH TOILET ROLL HOLDERTS TOILET SUITEWB WALL HUNG BASINWO WALL OVENWM WASHING MACHINE

NOTESN1:THE LOCATION OF SERVICES IS APPROXIMATE ONLY.BUILDER TO DETERMINE THE EXACT LOCATIONS OFSERVICES ON SITE PRIOR TO TENDERING.N2:DRAWINGS ARE TO BE READ IN CONJUNCTION WIITHJOINERY SCHEDULE IN SPECIFICATIONN3:CHECK & CONFIRM ALL DIMENSIONS ON SITE PRIOR TOMANUFACTURING / CONSTRUCTIONN4:UNLESS OTHERWISE NOTED, ALL INTERNAL CARCASSESTO BE WHITE MELAMINEN5:ALL WET AREAS TO COMPLY WITH AS 3740. WALL FINISHESSHALL BE IMPERVIOUS TO A HEIGHT OF 1800mm ABOVEFLOOR LEVEL TO SHOWER ENCLOSURES AND 300mmABOVE BATHS, BASINS, SINKS AND TROUGHS IF WITHIN75mm OF THE WALL. REFER TO CODE FOR ALLREQUIREMENTS.N6:W.C. DOORS TO TOILET PANS LOCATED WITHIN 1.2m OFTHE DOOR JAMB LIFT OFF HINGES MUST BE FITTED.OTHERWISE THE DOORS MUST SWING OUTWARDS.N7:SAFETY GLASS TO BE USED IN THE FOLLOWING CASES:I) ALL ROOMS – WITHIN 500mm VERTICAL OF THE FLOOR.II) BATHROOMS – WITHIN 2000mm OF THE FLOOR.III) LAUNDRY – WITHIN 1200mm VERTICAL FROM FLOORAND/OR WITHIN 300mm HORIZONTAL FROM ALL DOORS.IV) DOORWAY – WITHIN 300mm HORIZONTAL FROMDOORS.SHOWER SCREENS SHALL BE GRADE A SAFETY GLASS.

J0 JOINERY NO.

XX MATERIAL

W0 WINDOW NO.

D0 DOOR NO.

IE 10

IE 09

IE 13

IE 14IE 11

IE 12

90 1,100 10 910 90

90 2,020 90 3,590 30

901,810

93010

1,510

904,260

90

1201,770901,730906201,40090

1203,590902,02090

903,690

90450

120

903,690

540120

900

2,70

0

900

900

300

2,70

0

W10

300

560

40

900

300

1,00

050

0

2,70

0

900

900

300

600

2,10

060

0

1,20

030

01,

200

300

300

300

300

300

300

300

300

300

2,70

0

1,70

010

020

010

0

D11

2,40

030

0

2,70

0

300

300

300

300

300

300

300

300

90

900

90

900

300

560

40

900

300

1,00

050

0

D12

PLAN DETAIL - BATH & BED 31:50

INT. ELEV. 10 - BATH1:50IE 10INT. ELEV. 09 - BATH

1:50IE 09

INT. ELEV. 13 -BED 31:50IE 13 INT. ELEV. 14 - BED 3

1:50IE 14

INT. ELEV. 11 - BATH1:50IE 11

INT. ELEV. 12 - BATH1:50IE 12

TL2

TL1

RS1

TL1TSK

PB2

TL1

PB2

CA1

PB

CA1

PB

MDF

LA1

RS1

W10

D12

D11

D10

D9

W9

TL2

SEMI-FRAMELESSSHOWER SCREEN

1:50 @ A3

SHH

TS

BNMX

MI

SHR

MX

SHH

SHR

MX

FRAMELESS

TRH

MX

BN

TR TR

TRH

NS

HR

FS

FS

FS

FS

FS

DRW

DRW

DRW

BATHTILES CARPET

BED 3

FWNS

TS

TR

TRH

BN.

TR

MX

HR

Page 22: CONSTRUCTION - Derbyshire · as 3740 - waterproofing of wet areas in residential buildings as 3959 - construction in a bushfire prone area as 3786 - smoke alarms as 4055 - wind loadings

Project No:

Drawn:

Date:

Revision:

Scale:

Drawing No:

Drawing:Project:

Torquay, VIC., 3228

PLAN DET. & INT. ELEV. -BED 2, LAUNDRY, PANTRY& KITCHEN

14-66 15/12/2015

BA - A19 of 20

98 Pakington Street, Geelong West, Vic., 3218

T 5221 8409 F 5229 7433

[email protected]

www.derbyshire.com.au

ABN 80 060 577 648

Revisions:- - -

DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes

CONSTRUCTION

MATERIALS:CA1 CARPETCOS CONCRETE SLABFSS FRAMELESS SHOWER SCREENGMD GLOSS MELAMINE DOORSGS GLASS SPLASHBACKKI1 KICKER TYPE 1LA1 LAMINATE TYPE 1LB1 LAMINATED BENCHTOPMA1 WHITE MELAMINEMDF PAINTED MDFMS1 MIRROR SPLASHBACKPB PLASTERBOARD PAINT FINISHPB2 WET AREA PLASTERBOARD - VILLABOARDRS1 RECONSTITUTED STONESK TIMBER SKIRTINGTF TIMBER FLOORINGTL1 FLOOR TILETL2 WALL TILETSP TILE SPLASHBACK.TSK TILE SKIRTINGVW1 VINYL WRAP

REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH

ABBREVIATIONS:AS ADJUSTABLE SHELFBS BATH SPOUTCSD CAVITY SLIDING DOORCTB COUNTER TOP BASINDRW DRAWERDRY DRYERDW DISHWASHERFCL FINISHED CEILING LEVELFFL FINISHED FLOOR LEVELFS FIXED SHELFFW FLOOR WASTEGFS GLAZED FIXED SHELFGPO GENERAL PURPOSE OUTLETHR HANGING RAILHTR HAND TOWEL RAILLTR LAUNDRY TROUGHMH MANHOLEMI MIRRORMX MIXER TAPMW MICROWAVENOM NOMINAL LENGTHNS NOOK SHELFOS OPEN SHELFPL PENDANT LIGHTRA RETURN AIR DUCTREF REFRIGERATORS(U) SINK UNDERMOUNTSHR SHOWERSHH SHOWER HEADTR TOWEL RAIL (TR(H) - heated)TRH TOILET ROLL HOLDERTS TOILET SUITEWB WALL HUNG BASINWO WALL OVENWM WASHING MACHINE

NOTESN1:THE LOCATION OF SERVICES IS APPROXIMATE ONLY.BUILDER TO DETERMINE THE EXACT LOCATIONS OFSERVICES ON SITE PRIOR TO TENDERING.N2:DRAWINGS ARE TO BE READ IN CONJUNCTION WIITHJOINERY SCHEDULE IN SPECIFICATIONN3:CHECK & CONFIRM ALL DIMENSIONS ON SITE PRIOR TOMANUFACTURING / CONSTRUCTIONN4:UNLESS OTHERWISE NOTED, ALL INTERNAL CARCASSESTO BE WHITE MELAMINEN5:ALL WET AREAS TO COMPLY WITH AS 3740. WALL FINISHESSHALL BE IMPERVIOUS TO A HEIGHT OF 1800mm ABOVEFLOOR LEVEL TO SHOWER ENCLOSURES AND 300mmABOVE BATHS, BASINS, SINKS AND TROUGHS IF WITHIN75mm OF THE WALL. REFER TO CODE FOR ALLREQUIREMENTS.N6:W.C. DOORS TO TOILET PANS LOCATED WITHIN 1.2m OFTHE DOOR JAMB LIFT OFF HINGES MUST BE FITTED.OTHERWISE THE DOORS MUST SWING OUTWARDS.N7:SAFETY GLASS TO BE USED IN THE FOLLOWING CASES:I) ALL ROOMS – WITHIN 500mm VERTICAL OF THE FLOOR.II) BATHROOMS – WITHIN 2000mm OF THE FLOOR.III) LAUNDRY – WITHIN 1200mm VERTICAL FROM FLOORAND/OR WITHIN 300mm HORIZONTAL FROM ALL DOORS.IV) DOORWAY – WITHIN 300mm HORIZONTAL FROMDOORS.SHOWER SCREENS SHALL BE GRADE A SAFETY GLASS.

J0 JOINERY NO.

XX MATERIAL

W0 WINDOW NO.

D0 DOOR NO.

D

F

W

DW

IE 15

IE 18

IE 17

IE 19

IE 23

IE 24

IE 21

IE 25

IE 16

IE 22

IE 20

90 3,620 90 1,800 90 610 2,100

90 720 2,900 90 610 1,190 90 610 1,200 900

4,65090

9001,810901,200600902,900710100

2,710901,800903,610100

2,9401,200

61090

904,650

90

902,750

901,810

90

1,05

090

015

030

0

2,40

030

0

300

300

300

300

300

300

300

1,95

015

030

030

0

2,70

0

900

600

900

300

2,70

0

9077

040

900

600

900

300

2,70

0

2,40

030

0

2,70

0

D2

1,05

090

015

0

2,10

030

0

2,40

0

W4

PLAN DETAIL - BED 2, PANTRY, LAUNDRY & KITCHEN1:50

INT. ELEV. 15 - BED 21:50IE 15

INT. ELEV. 18 - L'DRY1:50IE 18INT. ELEV. 17 - L'DRY

1:50IE 17 INT. ELEV. 19 - L'DRY1:50IE 19

INT. ELEV. 16 - BED 21:50IE 16

CA1

CA1

TL1

TSP

TL1

LB1

TL1

LA1 LA1

LA1 LA1

LA1

LB1

TSP

PB

MDF MDFMDFMDF

PB

TSK

1:50 @ A3

FS

FS

FS

FS FS

FS

FS

FS

FS

FS

FS

FS

FS

FS

FS

FS

TR MX

WMDRY

FS FS FS FS

FS

FS

FS

DRW

DRW

DRW

DRW

HR HR HR

HR HR

HR

HR

FS

FS

FS

FS

FS

FS

L'DRYTILESCARPET

BED 2 KITCHENTILES

Page 23: CONSTRUCTION - Derbyshire · as 3740 - waterproofing of wet areas in residential buildings as 3959 - construction in a bushfire prone area as 3786 - smoke alarms as 4055 - wind loadings

Project No:

Drawn:

Date:

Revision:

Scale:

Drawing No:

Drawing:Project:

Torquay, VIC., 3228

PLAN DET. & INT. ELEV. -KITCHEN

14-66 15/12/2015

BA - A20 of 20

98 Pakington Street, Geelong West, Vic., 3218

T 5221 8409 F 5229 7433

[email protected]

www.derbyshire.com.au

ABN 80 060 577 648

Revisions:- - -

DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes

CONSTRUCTION

9077

040

D8

W5

9077

040

900

600

900

300

900

900

600

2,40

0

D8

9077

040

900

600

1,80

060

030

0

2,70

0

W5

9077

040

900

9077

040

900

600

900

300

2,70

0

9077

040

900

9077

040

900

600

900

300

2,70

0

MATERIALS:CA1 CARPETCOS CONCRETE SLABFSS FRAMELESS SHOWER SCREENGMD GLOSS MELAMINE DOORSGS GLASS SPLASHBACKKI1 KICKER TYPE 1LA1 LAMINATE TYPE 1LB1 LAMINATED BENCHTOPMA1 WHITE MELAMINEMDF PAINTED MDFMS1 MIRROR SPLASHBACKPB PLASTERBOARD PAINT FINISHPB2 WET AREA PLASTERBOARD - VILLABOARDRS1 RECONSTITUTED STONESK TIMBER SKIRTINGTF TIMBER FLOORINGTL1 FLOOR TILETL2 WALL TILETSP TILE SPLASHBACK.TSK TILE SKIRTINGVW1 VINYL WRAP

REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH

ABBREVIATIONS:AS ADJUSTABLE SHELFBS BATH SPOUTCSD CAVITY SLIDING DOORCTB COUNTER TOP BASINDRW DRAWERDRY DRYERDW DISHWASHERFCL FINISHED CEILING LEVELFFL FINISHED FLOOR LEVELFS FIXED SHELFFW FLOOR WASTEGFS GLAZED FIXED SHELFGPO GENERAL PURPOSE OUTLETHR HANGING RAILHTR HAND TOWEL RAILLTR LAUNDRY TROUGHMH MANHOLEMI MIRRORMX MIXER TAPMW MICROWAVENOM NOMINAL LENGTHNS NOOK SHELFOS OPEN SHELFPL PENDANT LIGHTRA RETURN AIR DUCTREF REFRIGERATORS(U) SINK UNDERMOUNTSHR SHOWERSHH SHOWER HEADTR TOWEL RAIL (TR(H) - heated)TRH TOILET ROLL HOLDERTS TOILET SUITEWB WALL HUNG BASINWO WALL OVENWM WASHING MACHINE

NOTESN1:THE LOCATION OF SERVICES IS APPROXIMATE ONLY.BUILDER TO DETERMINE THE EXACT LOCATIONS OFSERVICES ON SITE PRIOR TO TENDERING.N2:DRAWINGS ARE TO BE READ IN CONJUNCTION WIITHJOINERY SCHEDULE IN SPECIFICATIONN3:CHECK & CONFIRM ALL DIMENSIONS ON SITE PRIOR TOMANUFACTURING / CONSTRUCTIONN4:UNLESS OTHERWISE NOTED, ALL INTERNAL CARCASSESTO BE WHITE MELAMINEN5:ALL WET AREAS TO COMPLY WITH AS 3740. WALL FINISHESSHALL BE IMPERVIOUS TO A HEIGHT OF 1800mm ABOVEFLOOR LEVEL TO SHOWER ENCLOSURES AND 300mmABOVE BATHS, BASINS, SINKS AND TROUGHS IF WITHIN75mm OF THE WALL. REFER TO CODE FOR ALLREQUIREMENTS.N6:W.C. DOORS TO TOILET PANS LOCATED WITHIN 1.2m OFTHE DOOR JAMB LIFT OFF HINGES MUST BE FITTED.OTHERWISE THE DOORS MUST SWING OUTWARDS.N7:SAFETY GLASS TO BE USED IN THE FOLLOWING CASES:I) ALL ROOMS – WITHIN 500mm VERTICAL OF THE FLOOR.II) BATHROOMS – WITHIN 2000mm OF THE FLOOR.III) LAUNDRY – WITHIN 1200mm VERTICAL FROM FLOORAND/OR WITHIN 300mm HORIZONTAL FROM ALL DOORS.IV) DOORWAY – WITHIN 300mm HORIZONTAL FROMDOORS.SHOWER SCREENS SHALL BE GRADE A SAFETY GLASS.

J0 JOINERY NO.

XX MATERIAL

W0 WINDOW NO.

D0 DOOR NO.

9077

040

900

900

9077

040

900

INT. ELEV. 23 - KITCHEN1:50IE 23

INT. ELEV. 24 - KITCHEN1:50IE 24

INT. ELEV. 21 - KITCHEN1:50IE 21

INT. ELEV. 25 - KITCHEN1:50IE 25

INT. ELEV. 20 - KITCHEN1:50IE 20

INT. ELEV. 22 - KITCHEN1:50IE 22

RS1

RS1 RS1

RS1

RS1

RS1 RS1

TL1TL1

TL1 TL1

TL1TL1

PB

PB

GS

RS1

DRW

DRW

DRW

DRW

DRW

DRW

DRW

DRW

DRW

DRW

DRW

DRW

DRW

DRW

DRW

DRW

DRW

DRW

FS

FS

FS

FS

DRW

DRW

DRW

FS

FS

S(U)MX

DW

FS

FS

MXBN

MX BN

REF

FS

DRW

DRW

DRW

FS

COOKTOP

OVENFS

FS

RANGEHOOD

FS