Project No:
Drawn:
Date:
Revision:
Scale:
Drawing No:
Drawing:Project:
Torquay, VIC., 3228
98 Pakington Street, Geelong West, Vic., 3218
T 5221 8409 F 5229 7433
www.derbyshire.com.au
ABN 80 060 577 648
DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes
COVER SHEETCONSTRUCTION 14-66 15/12/2015
BA -
Revisions:- - -
#
A00
A01
A02
A02A
A03
A04
A05
A06
A07
A08
A09
A10
A11
A12
A13
A14
A15
A16
A17
A18
A19
A20
DRAWING NAME:
COVER SHEET
GENERAL NOTES
SITE PLAN
FLOOR PLAN
SLAB SETOUT PLAN
ELEVATIONS SHT.1
ELEVATIONS SHT.2
REFLECTED CEILING PLAN
ELECTRICAL PLAN
ROOF PLAN
SECTION 1
SECTION 2
SECTION 3
SECTION 4 SHT.1
SECTION 4 SHT.2
DOOR SCHEDULE SHT.1
DOOR SCHEDULE SHT.2
WINDOW SCHEDULE SHT.1
WINDOW SCHEDULE SHT.2
PLAN DET. & INT. ELEV - MASTERBED ENS. & WIR
PLAN DET. & INT. ELEV. - BATH &BED 3
PLAN DET. & INT. ELEV. - BED 2,LAUNDRY, PANTRY & KITCHEN
PLAN DET. & INT. ELEV. -KITCHEN
SCALE
-
-
1:200
1:100
1:100
1:100
1:100
1:100
1:100
1:50
1:50
1:50
1:50
1:50
1:50
1:50
1:50
1:50
1:50
1:50
1:50
1:50
REV.
-
-
-
A
A
A
-
-
-
-
-
-
-
-
-
-
A
-
A
-
-
-
Project No:
Drawn:
Date:
Revision:
Scale:
Drawing No:
Drawing:Project:
Torquay, VIC., 3228
GENERAL NOTES14-66 15/12/2015
BA - A00 of 20
98 Pakington Street, Geelong West, Vic., 3218
T 5221 8409 F 5229 7433
www.derbyshire.com.au
ABN 80 060 577 648
Revisions:- - -
DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes
CONSTRUCTION
GENERAL NOTESN1:NCC 2014 BCA VOL 2ALL MATERIALS AND WORK PRACTICES SHALL COMPLY WITH,BUT NOT LIMITED TO THE BUILDING REGULATIONS 2006,NATIONAL CONSTRUCTION CODE SERIES 2014 BUILDING CODEOF AUSTRALIA VOL 2 AND ALL RELEVANT CURRENTAUSTRALIAN STANDARDS (AS AMENDED) REFERRED TOTHEREIN. UNLESS OTHERWISE SPECIFIED, THE TERM NCCSHALL REFER TO NATIONAL CONSTRUCTION CODE SERIES2014 BUILDING CODE OF AUSTRALIA VOLUME 2.ALL MATERIALS AND CONSTRUCTION PRACTICE SHALL MEETTHE PERFORMANCE REQUIREMENTS OF THE BCA. WHERE ANALTERNATIVE SOLUTION IS PROPOSED THEN, PRIOR TOIMPLEMENTATION OR INSTALLATION, IT FIRST MUST BEASSESSED AND APPROVED BY THE RELEVANT BUILDINGSURVEYOR AS MEETING THE PERFORMANCE REQUIREMENTSOF THE NCC.
N2:THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ANYHOUSE ENERGY RATING (HERS) REPORT AND SHALL BECONSTRUCTED IN ACCORDANCE WITH THE STAMPED PLANSENDORSED BY THE ACCREDITED THERMAL PERFORMANCEASSESSOR WITHOUT ALTERATION
N3:INSTALLATION OF ALL SERVICES SHALL COMPLY WITH THERESPECTIVE SUPPLY AUTHORITY REQUIREMENTS.
N4:DO NOT SCALE PLANS, USE WRITTEN DIMENSIONS ONLY.FIGURED DIMENSIONS TAKE PRECEDENCE OVER SCALEDDIMENSIONS.
N5:THE OWNER, BUILDER, SUBCONTRACTOR SHALL VERIFY ALLDIMENSIONS, LEVELS, SETBACKS AND SPECIFICATIONS PRIORTO COMMENCING ANY WORKS OR ORDERING MATERIALS ANDSHALL BE RESPONSIBLE FOR ENSURING THAT ALL BUILDINGWORKS CONFORM TO THE BUILDING CODE OF AUSTRALIA, ASCODES (CURRENT EDITIONS), BUILDING REGULATIONS, LOCALBY-LAWS AND TOWN PLANNING REQUIREMENTS. REPORT ALLDISCREPANCIES TO THIS OFFICE FOR CLARIFICATION.
N6:ALL WORKS SHALL COMPLY WITH BUT NOT LIMITED TO THEFOLLOWING AUSTRALIAN STANDARDS:AS 1288 - GLASS IN BUILDINGS – SELECTION AND
INSTALLATION.AS 1562 - DESIGN AND INSTALLATION OF SHEET ROOF AND
WALL CLADDINGAS 1684 - RESIDENTIAL TIMBER FRAMED CONSTRUCTIONAS 1860 - INSTALLATION OF PARTICLE BOARD FLOORINGAS 2047 - INSTALLATION AND SELECTION OF WINDOWSAS 2049 - ROOF TILESAS 2050 - FIXING OF ROOF TILESAS 2870 - RESIDENTIAL SLABS AND FOOTINGS.AS 2904 - DAMP PROOF COURSES AND FLASHINGSAS 3500 - PLUMBING & DRAINAGEAS 3600 - CONCRETE STRUCTURESAS 3660 - PROTECTION OF BUILDINGS FROM SUBTERRANEAN
TERMITES.AS 3700 - MASONRY IN BUILDINGS.AS 3740 - WATERPROOFING OF WET AREAS IN RESIDENTIAL
BUILDINGSAS 3959 - CONSTRUCTION IN A BUSHFIRE PRONE AREAAS 3786 - SMOKE ALARMSAS 4055 - WIND LOADINGS FOR HOUSINGAS 4100 - STEEL STRUCTURES
N7:THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANYSTRUCTURAL OR CIVIL ENGINEERING COMPUTATIONS ANDDRAWINGS; AND ALL OTHER CONSULTANTS DRAWINGS /DETAILS AND WITH ANY OTHER WRITTEN INSTRUCTIONSISSUED IN THE COURSE OF THE CONTRACT.
N8:WHERE REQUIRED TREAT AREA BENEATH FLOOR AGAINSTTERMITE INFESTATION IN ACCORDANCE WITH RELEVANTSTANDARD. CONTACT THE RELEVANT MUNICIPAL COUNCIL TODETERMINE IF THIS IS MANDATORY
N9:GLAZING, INCLUDING SAFETY GLAZING, SHALL BE INSTALLEDTO A SIZE, TYPE AND THICKNESS SO AS TO COMPLY WITH:- BCAPART 3 FOR CLASS 1 AND 10 BUILDINGS WITHIN A DESIGNWIND SPEED OF NOT MORE THAN N3; AND - NCC 2014 BCA VOL1 PART B1.4 FOR CLASS 2 AND 9 BUILDINGS.SAFETY GLASS TO BE USED IN THE FOLLOWING CASES:I) ALL ROOMS – WITHIN 500mm VERTICAL OF THE FLOOR.II) BATHROOMS – WITHIN 2000mm OF THE FLOOR.III) LAUNDRY – WITHIN 1200mm VERTICAL FROM FLOOR AND/ORWITHIN 300mm HORIZONTAL FROM ALL DOORS. IV) DOORWAY –WITHIN 300mm HORIZONTAL FROM DOORS.SHOWER SCREENS SHALL BE GRADE A SAFETY GLASS.
N10:WINDOW SIZES ARE NOMINAL ONLY, ACTUAL SIZE WILL VARYACCORDING TO MANUFACTURER. WINDOWS TO BE FLASHEDALL AROUND.
SITE ENVIRONMENT DESIGNINFORMATIONSEN1:SITE BUSHFIRE ATTACK ASSESSMENTREFERENCE DOCUMENT 'AS 3959-2009 CONSTRUCTION OF BUILDINGS INBUSH FIRE PRONE AREASTHIS PROPERTY IS ON A DESIGNATED BUSHFIRE PRONE AREABAL RATING LOW
SEN2:SITE CLASSIFICATIONSITE CLASSIFICATION AS CLASS: MREFER TO SOIL REPORT NO: 67522DATED: 20/05/215BY: INTRAX CONSULTING ENGINEERS PTY. LTD.
SEN3:DESIGN GUST WIND SPEED / WIND CLASSIFICATIONWIND RATING: N2BUILDING TIE DOWNS TO BE PROVIDED IN ACCORDANCE WITH AS1684-2006 FOR AN ASSUMED DESIGN GUST WIND SPEED / WINDCLASSIFICATION OF N3. REFER TO AS1684 FOR CONSTRUCTIONREQUIREMENTSREFER TO WIND CLASSIFICATION REPORT: 67522DATED: 20/05/2015BY: INTRAX CONSULTING ENGINEERS PTY. LTD.
SEN4:CLIMATE ZONECLIMATE ZONE FOR THERMAL DESIGN / THERMAL PERFORMANCE
ASSESSMENT: ZONE 6
SEN5:CORROSION PROTECTION OF BUILT-INSTRUCTURAL MEMBERS.
PROVIDE CORROSION PROTECTION OF BUILT-IN STRUCTURAL STEELMEMBERS SUCH AS STEEL LINTELS, SHELF ANGLES, CONNECTORS,ACCESSORIES (OTHER THAN WALL TIES) IN ACCORDANCE WITH TABLE 4.1OF AS4773.1-2010 MASONRY IN SMALL BUILDINGS, PART 1: DESIGNSUITABLE FOR AN ENVIRONMENT CLASSIFICATION SEVERE MARINE
CORROSION PROTECTION FOR SHEET ROOFINGPROVIDE CORROSION PROTECTION FOR SHEET ROOFING INACCORDANCE WITH NCC TABLE 3.5.1.1A SUITABLE FOR AN ENVIRONMENTCLASSIFICATION HIGH TO VERY HIGH
SEN6:ENERGY RATING & REQUIREMENTSBY: INTRAX CONSULTING ENGINEERS PTY. LTD.
PROVIDE R4.0 INSULATION BATTS TO ALL ROOF AREAS EXCEPT GARAGE
PROVIDE R2.5 INSULATION BATTS TO ALL EXTERNAL WALLS ECEPTGARAGE
PROVIDE ANTI-GLARE REFLECTIVE FOIL SISALATION PAPER TO ALLEXTERNAL WALLS
WINDOWS W2, W2A, W7, W7A AND W10 AND GLAZED DOOR D02 ARESINGLE GLAZED (U=5.4, SHGC=0.58) OR SIMILAR PRODUCTS WITH SAME UAND SHGC VALUE
ALL OTHER PROPOSED WINDOWS AND GLAZED DOORS ARE DOUBLEGLAZED (U=3.5, SHGC=0.64) OR SIMILAR PRODUCTS WITH SAME U ANDSHGC VALUE
ALL EXHAUST FANS MUST BE FITTED WITH A SEALING DEVICE SUCH ASSELF-CLOSING DAMPER
ALL DOWNLIGHTS SHALL BE SEALED PREVENTING AIRFLOW BETWEENINTERNAL SPACE AND ROOF SPACE
ALLOWED INTERIOR LIGHTING POWER DENSITY 5W/M2, ALLOWEDEXTERIOR LIGHTING POWER 4WW/M2
WEATHERPROOF SEALS TO ALL NEW EXTERNAL DOORS AND WINDOWS.SEALS TO RESTRICT AIR INFILTRATION AND TO COMPLY WITH THEREQUIREMENTS OF NCC 2015 CLAUSE 3.12.3.3
INSULATION INSTALLATION OF THE BUILDING SHALL COMPLY WITH THEREQUIREMENTS OF NCC 2015 CLAUSE 3.12.1.1
THE CONSTRUCTION OF ROOF, WALLS, FLOORS, AND OPENABLEWINDOWS SHALL BE CONSTRUCTED TO MINIMISE AIR LEAKAGE INACCORDANCE WITH NCC 2015 CLAUSE 3.12.3.5
INSTALLATION OF EITHER A RAINWATER TANK CONNECTED TO ALLSANITARY FLUSHING SYSTEMS, OR A SOLAR WATER HEATER SYSTEMINSTALLED IN ACCORDANCE WITH THE PLUMBING REGULATIONS 2008
THIS RATING ONLY APPLIES TO THE FLOOR PLAN, CONSTRUCTION DETAIL,ORIENTATION AND CLIMATE AS SUBMITTED AND INCLUDED IN THEATTACHED STAMPED PLAN
CHANGES TO ANY OF THESE AREAS CAN AFFECT THIS RATING AND SHALLBE VERIFIED WITH THE ENERGY RATER PRIOR TO COMMENCEMENT OFANY WORKS.
N11:STORM WATER SHALL BE TAKEN TO LEGAL POINT OFDISCHARGE AS ADVISED BY THE MUNICIPAL DRAINAGEENGINEER. CONTACT THE COUNCIL IF UNSURE OF POINT OFDISCHARGE. 90 DIA. CLASS 6 UPVC STORMWATER LINE LAIDTO A MINIMUM GRADE OF 1:100. PROVIDE INSPECTIONOPENINGS AT 9000MM C/C AND AT EACH CHANGE OFDIRECTION. THE COVER TO UNDERGROUND STORMWATERDRAINS SHALL BE NOT LESS THAN:- 100MM UNDER SOIL- 50MM UNDER PAVED OR CONCRETE AREAS- 100MM UNDER UN-REINFORCED CONCRETE OR PAVEDDRIVEWAYS- 75MM UNDER REINFORCED CONCRETE DRIVEWAYS
N12:THE BUILDER AND SUBCONTRACTOR SHALL ENSURE THAT ALLSTORMWATER DRAINS, SEWER PIPES, AND THE LIKE ARELOCATED AT A SUFFICIENT DISTANCE FROM ANY BUILDINGSFOOTING AND/OR SLAB EDGE BEAMS SO AS TO PREVENTGENERAL MOISTURE PENETRATION, DAMPNESS, WEAKENINGAND UNDERMINING OF ANY BUILDING AND IT'S FOOTINGSYSTEM.
N13:SEWER OR SEPTIC SYSTEM SHALL BE IN ACCORDANCE WITHTHE RELEVANT AUTHORITIES REQUIREMENTS.
N14:FOOTINGS NOT TO ENCROACH TITLE BOUNDARIES ANDEASEMENT LINES. OWNER AND BUILDER TO ENSURE THISDOES NOT OCCUR.
N15:FOR BUILDINGS IN CLOSE PROXIMITY TO THE BEACH ENSURETHAT ALL STEEL WORK, BRICK CAVITY TIES AND STEELLINTELS, ETC THAT ARE IMBEDDED OR FIXED INTO MASONRYBE PROTECTED IN ACCORDANCE WITH AS 3700 HOT DIPPEDGALVANISED
N16:ALL WET AREAS TO COMPLY WITH AS 3740. WALL FINISHESSHALL BE IMPERVIOUS TO A HEIGHT OF 1800mm ABOVE FLOORLEVEL TO SHOWER ENCLOSURES AND 300mm ABOVE BATHS,BASINS, SINKS AND TROUGHS IF WITHIN 75mm OF THE WALL.REFER TO CODE FOR ALL REQUIREMENTS.
N17:PROVIDE WALL TIES TO BRICKWORK AT MAXIMUM 600mm CRSIN EACH DIRECTION AND WITHIN 300mm OF ARTICULATIONJOINTS.
N18:SUB FLOOR VENTS ARE TO PROVIDE A RATE OF 7500mm SQCLEAR VENTILATION PER 1000mm RUN OF EXTERNAL WALLAND 2200mm SQ CLEAR VENTILATION PER 1000mm RUN OFINTERNAL DWARF WALLS.(LOCATED BELOW BEARER)
N19:PROVIDE CLEARANCE FROM UNDERSIDE OF BEARERS TOFINISHED GROUND LEVEL OF 150mm FOR FLOOR WITH STRIPFLOORING OR 200mm FOR FLOORS WITH PARTICLEBOARDFLOORING AND 400mm IN A TERMITE DECLARED AREA.
N20:NEW DWELLINGS, TO COMPLY WITH A 5 STAR ENERGY RATINGREPORT (H.E.R.S.)
N21:STAIR REQUIREMENTS: RISERS – 190mm MAXIMUM - 115mmMINIMUM. GOING – 355mm MAXIMUM – 240mm MINIMUM.(DOMESTIC ONLY)RISERS AND TREADS TO BE CONSTANT IN SIZE THROUGHOUTFLIGHT. PROVIDE NON-SLIP FINISH OR SUITABLE NON-SKIDSTRIP NEAR EDGE OF NOSING'S. PROVIDE CONTINUOUSHANDRAIL 1000mm MINIMUM HEIGHT TO BALCONIES ANDDECKS WHICH ARE 1000mm OR MORE ABOVE GROUND LEVEL.865mm MINIMUM HEIGHT HANDRAIL ABOVE STAIR NOSING'SAND LANDINGS. MAXIMUM OPENINGS BETWEEN BALUSTERSNOT TO EXCEED 125mm AND MAXIMUM GAP TO OPEN TREADNOT TO EXCEED 125mmFOR WIRE BALUSTRADE SEE BCA VOLUME 2 REQUIREMENTS
N22:STUMPS EXCEEDING 1200mm ABOVE GROUND TO BE BRACEDCONCRETE STUMPS- 100mm SQ UP TO 1400mm LONG (1 No. HD. WIRE)- 100mm SQ 1400mm TO 1800mm LONG (2 No. HD. WIRES)- 125mm SQ 1800mm TO 3000mm LONG (2 No. HD. WIRES)
N23:THE BUILDER SHALL TAKE ALL STEPS NECESSARY TO ENSURETHE STABILITY OF NEW AND EXISTING STRUCTURES DURINGALL WORKS.
N24:THE BUILDER SHALL ENSURE FOR THE GENERALWATERTIGHTNESS OF ALL NEW AND EXISTING WORKS.
N25:SMOKE ALARMS TO BE PROVIDED AND INSTALLED INACCORDANCE WITH AS3786. NEW DWELLINGS AND ADDITIONSWITH SLEEPING ACCOMMODATION TO BE HARD WIRED WITHBATTERY BACK UP.
N26:WHERE BUILDING IS WITHIN A DESIGNATED BUSHFIRE PRONEAREA COMPLIANCE WITH AS 3959 - IS REQUIRED TO A LEVELOF ATTACK AS CONFIRMED BY THE RELEVANT BUILDINGSURVEYOR.
N27:W.C. DOORS TO TOILET PANS LOCATED WITHIN 1.2m OF THEDOOR JAMB LIFT OFF HINGES MUST BE FITTED. OTHERWISETHE DOORS MUST SWING OUTWARDS.
N28:TERMITE CERTIFICATE (WHERE REQUIRED) TO BE INSTALLEDINSIDE METER BOX PRIOR TO OCCUPANCY PERMIT ORCERTIFICATE OF FINAL INSPECTION ISSUE.
N29:THESE NOTES ARE NEITHER EXHAUSTIVE NOR A SUBSTITUTEFOR REGULATIONS, STATUTORY REQUIREMENTS, BUILDINGPRACTICE OR CONTRACTUAL OBLIGATIONS AND UNLESSEXPRESSLY STATED OTHERWISE, ARE PROVIDED ONLY ASGUIDELINES. NO RESPONSIBILITY IS ACCEPTED FOR THEIRUSE.
N30:THESE PLANS HAVE BEEN PREPARED FOR THE EXCLUSIVEUSE BY THE CLIENT OF DERBYSHIRE FOR THE PURPOSEEXPRESSED NOTIFIED TO DERBYSHIRE. ANY OTHER PERSONWHO USES OR RELIES ON THESE PLANS WITHOUTDERBYSHIRE'S WRITTEN CONSENT DOES SO AT THEIR OWNRISK AND NO RESPONSIBILITY IS ACCEPTED BY DERBYSHIREFOR SUCH USE AND/OR RELIANCE.
N31:THE APPROVAL BY THIS OFFICE OF A SUBSTITUTE MATERIAL,WORK PRACTICE, VARIATION OR THE LIKE IS NOT ANAUTHORISATION FOR ITS USE OR A CONTRACT VARIATION.ANY SAID VARIATIONS MUST BE ACCEPTED BY ALL PARTIES TOTHE AGREEMENT AND WHERE APPLICABLE THE RELEVANTBUILDING SURVEYOR PRIOR TO IMPLEMENTING THE SAIDVARIATION.
Project No:
Drawn:
Date:
Revision:
Scale:
Drawing No:
Drawing:Project:
Torquay, VIC., 3228
SITE PLAN14-66 15/12/2015
BA - A01 of 20
98 Pakington Street, Geelong West, Vic., 3218
T 5221 8409 F 5229 7433
www.derbyshire.com.au
ABN 80 060 577 648
Revisions:- - -
DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes
CONSTRUCTION
100.2
100.0
100.2
100.0
100.4
100.50
100.47100.48
100.35100.31
100.22100.1899.96
100.01
100.15
100.29
100.39100.36
100.30
100.14
99.98
99.92
99.94
99.99
100.11
100.25
100.27
PE
GP
EG
PE
GP
EG
SE
WE
RM
AN
HO
LE
ST
OR
MW
AT
ER
PO
INT
ELE
CT
RIC
ITY
PIT
ST
OR
MW
AT
ER
PIT
CA
BLE
PIT
100.04
100.19
99.79
99.65
EXPOSED AGGREGATECONCRETE DRIVEWAY
TBM TOP OFELECTRICITY PIT
RL 100.00m
MATERIALS & FINISHES SCHEDULECA1 CARPETCB COLORBONDPB PLASTERBOARD PAINT FINISHRF RENDERED FOAMTD TIMBER DECKING
REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH.
ABBREVIATIONS:DP DOWNPIPEFFL FINISHED FLOOR LEVELRL RELATIVE LEVELRWT RAINWATER TANKMB ELECTRICAL METERBOARDMG GAS METERMW WATER METERIHW INSTANTANEOUS HOT WATERG SWINGING GATE
NOTESN1:THE LOCATION OF SERVICES IS APPROXIMATE ONLY.BUILDER TO DETERMINE THE EXACT LOCATION OFSERVICES ON SITE PRIOR TO CONSTRUCTION.N2:ALL EXISTING SITE LEVELS SHOWN ON THESE DRAWINGSARE BASED ON SURVEY PLAN PREPARED BY INTRAX DWGREF NO.67522 REV. -. DATED 18.05.15. BUILDER TOCONFIRM ALL LEVELS ON SITE.N3:REFER TO ROOF PLAN FOR DETAILS OF ROOFING ANDROOF PLUMBINGN4:REFER TO STRUCTURAL ENGINEERS DRAWINGS FORDETAILSN5:MIN FALLS 1:100. SUBSOIL DRAINS TO ALL RETAININGWALLS. CONNECT TO STORMWATER SYSTEM.N6:BUILDER TO ALLOW FOR ALL NECESSARY EXCAVATION,BACKFILLING AND OTHER EARTH MOVING TO RE-ESTABLISH EXISTING GROUND LEVELS EXCEPT WHERENOTED OTHERWISEN7:LOCATION OF TITLE BOUNDARY IS BASED ONASSUMPTION THAT EXISTING FENCES REPRESENT TRUEBOUNDARY. A RE-ESTABLISHMENT SURVEY MAY BEREQUIRED.
DEVELOPMENT DATAPROPOSED DATA - NEW RESIDENCESITE AREA: 495 M2 53.28 SQ
BUILDING SITE COVERAGE (AREA M2)GROUND FLOORHOUSE: 182.66 M2 19.66 SQGARAGE: 43 M2 4.63 SQDRIVEWAY 43 M2 4.63 SQPAVING: 29.75 M2 2.45 SQ
TOTAL BUILDING AREA: 225.66 M2 24.29 SQPERCENTAGE SITE COVERAGE: 298.41 M2 60.3 %
% IMPERVIOUS SURFACES: 196.59 M2 39.72%
EQUINOX SHADOW
9AM SHADOW @ EQUINOX
12 NOON SHADOW @ EQUINOX
3PM SHADOW @ EQUINOX
1:200 @ A3
EX
IST
ING
CR
OS
SO
VE
R
FO
OT
PA
TH
AE
RIA
L AV
E.
LOT 95VACANT OF
18.05.15
LOT 93VACANT OF
18.05.15
VACANT OF18.05.15
15.00M226
º56'00''
33.00M06º56'00''
33.00M06º56'00''
15.00M226
º56'00''
GARAGEFFL: 100.25
FFL: 100.4
PROPOSEDNEW
RESIDENCE
EA
SE
ME
NT
2.0M
NO.35
9AM SHADOW @ EQUINOX
12 NOON SHADOW @ EQUINOX
3PM SHADOW @ EQUINOX
Project No:
Drawn:
Date:
Revision:
Scale:
Drawing No:
Drawing:Project:
Torquay, VIC., 3228
FLOOR PLAN14-66 15/12/2015
BA - A02 of 20
98 Pakington Street, Geelong West, Vic., 3218
T 5221 8409 F 5229 7433
www.derbyshire.com.au
ABN 80 060 577 648
Revisions:- - -
DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes
CONSTRUCTION
D
F
W
DW
1,220905,8351203,590902,020903,420902,120902,63090
11020,185
1,9202,0591,8561,0821,8561,9828991,0507101,7228398991,8611,200360
1,200110
10,620240
1,070
1,9201,300
3,6142,662
899576
1,22090
4,230120
1,53090
4,65090
1,220
90 500230
6,080 90 3,620 90 1,800 90 7,315 90 1,220
7,140 1,153 1,722 3,384 1,856 2,839 2,050
2404,260
90
2,2504,590
1,5306,630
2,35090
1,820
6,990 150 12,765 240 1,070
920901,62090
2,710901,190610902,9109062090
1002,4263,1432,432
2,43290
100
7,370 20,145 5,485
2,38010,970
1,650
5,61520,2957,090
2306,170
230
906,300
240
2302,375
901,895
E/3A04
E/4A04
E/1A03
E/2A03
RD
2
RD
1
D9
D7
D5
D6
D11
D12D13
W4 W5D2
W6
W2
W1
W2A
D14
W3
D1
D4
D8
D13A
W7
W7A
D3
W12W13 W11
D10
W10 W8W9
S/2A09
S/4A11
S/3A10
S/1A08
MATERIALS & FINISHES SCHEDULEBW BRICKWORKCA CARPETCB COLORBONDCOS CONCRETE SLABPB PLASTERBOARD PAINT FINISHSC SCYON 'MATRIX' CLADDING OR SIMILAR
REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH
ABBREVIATIONS:BAL BALUSTRADEBG BOX GUTTERCOL STEEL COLUMNCSD CAVITY SLIDING DOORDP DOWNPIPEDS DOUBLE STUDSDW DISHWASHERFL FLOOR LEVELFW FLOOR WASTEFWB FEATURE WINDOW BOXING - ALUMINIUMG SWINGING GATEIHW INSTANTANEOUS HOT WATERMB ELECTRICAL METERBOARDRF RIDGE FLASHINGRH RANGEHOODRL RELATIVE LEVELRWT RAINWATER TANKSHR SHOWERST STOVETR TROUGHTS TOILET SUITEVB VANITY BASINWM WASHING MACHINEWO WALL OVEN
NOTESN1:ALL DIMENSIONS TO BE CHECK AND VERIFIED ON SITE.DO NOT SCALE FROM DRAWINGSN2:CONTRACTOR TO OBTAIN DERBYSHIRE'S PRIOR WRITTENAPPROVAL FOR ANY EXTRA WORK OR ALTERATIONS TOAPPROVED DRAWINGSN3:A FULL SET OF LAMINATED DRAWINGS ANDSPECIFICATIONS TO BE KEPT ON SITE IN GOODCONDITION AT ALL TIMESN4:SHOULD DISCREPANCIES OR ERROR BE DISCOVERED ONTHE DRAWINGS OR SPECIFICATIONS, DERBYSHIRE MUSTBE NOTIFIED IMMEDIATELYN5:ALL BUILDING WORKS TO BE COMPLETED INACCORDANCE WITH THE NCC/BCA AND TO THESATISFACTION OF THE LOCAL AUTHORITY AND ORBUILDING SURVEYORN6:REFER TO DOOR & WINDOW SCHEDULES FOR COMPLETEDIMENSIONS & DETAILSN7:WATERPROOFING OF WET AREAS, BEING BATHROOMS,SHOWERS, SHOWER ROOMS, LAUNDRIES, SANITARYCOMPARTMENTS AND THE LIKE SHALL BE PROVIDED INACCORDANCE WITH AS3740-2010: WATERPROOFING OFDOMESTIC WET AREAS
J0 JOINERY NO.
XX MATERIAL
W0 WINDOW NO.
D0 DOOR NO.
COLORBONDCORRUGATEDMETAL SHEETCLADDING
HARDWOODTIMBER
SCREEN.90X32MM
64MM GAPS
BRICKWORK
HARDWOODTIMBERSCREEN.50MM GAPS.
BRICKWORK
REFER TO ENGINEERSSTRUCTURAL
DRAWINGS FOR DETAIL
ACCESS HATCH DOOR600MM X 600MM
50MMSHOWERRECESS
50MMSHOWERRECESS
GARAGE
PASSAGE
BED 2
RO
BE
BED 3MASTER BEDBATHWIRENS
LIVING
DININGKITCHEN
L'D
RY
ENTRY
1:100 @ A3
FFL 100.4 FFL 100.4
TILESTILES
SITE BOUNDARY
SITE BOUNDARY
SIT
E B
OU
ND
AR
Y
SIT
E B
OU
ND
AR
Y
FFL 100.25
ROBE
CONCRETE
CARPET
TILES TILES
CARPETCARPET TILES TILES
TILESTILES
TIL
ES
(EA
VE
OV
ER
)
POST
COL.
COL.
COL.
COL.
DP DP
DPDPDP
(EA
VE
OV
ER
)
EX
PO
SE
DA
GG
RE
GA
TE
CO
NC
RE
TE
NOPOSTCSD
CS
D
CS
D
CSDC
SD
HWS
TAP
TAPDP
DP
EXPOSEDAGGREGATECONCRETE
Revisions:A W11 POSITION MOVED 15.12.15
A
Project No:
Drawn:
Date:
Revision:
Scale:
Drawing No:
Drawing:Project:
Torquay, VIC., 3228
SLAB SETOUT PLAN14-66 15/12/2015
BA - A02A of 20
98 Pakington Street, Geelong West, Vic., 3218
T 5221 8409 F 5229 7433
www.derbyshire.com.au
ABN 80 060 577 648
Revisions:- - -
DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes
CONSTRUCTION
1506,490
1,5204,440
2,400
280 1,430
710 720 5,570
1,710
901,520
901,520
1,6504,840
5,960
E/3
E/4A04
E/1A03
E/2A03 S/2
A09
S/4A11
S/3A10
S/1A08
1506,490
1,5204,440
2,400
280 1,430
8,080 6,290 12,995 1,220
12,7051,510
1,22010,800
1,220
58013,240
1,180
1,22020,275
4,0506,8959206,9109201,800
710 720 5,570
1,710
901,520
901,520
1,6504,840
5,960
E/3A04
E/4A04
E/1A03
E/2A03 S/2
A09
S/4A11
S/3A10
S/1A08
MATERIALS & FINISHES SCHEDULEBW BRICKWORKCA CARPETCB COLORBONDCOS CONCRETE SLABPB PLASTERBOARD PAINT FINISHSC SCYON 'MATRIX' CLADDING OR SIMILAR
REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH
ABBREVIATIONS:BAL BALUSTRADEBG BOX GUTTERCOL STEEL COLUMNCSD CAVITY SLIDING DOORDP DOWNPIPEDS DOUBLE STUDSDW DISHWASHERFL FLOOR LEVELFW FLOOR WASTEFWB FEATURE WINDOW BOXING - ALUMINIUMG SWINGING GATEIHW INSTANTANEOUS HOT WATERMB ELECTRICAL METERBOARDRF RIDGE FLASHINGRH RANGEHOODRL RELATIVE LEVELRWT RAINWATER TANKSHR SHOWERST STOVETR TROUGHTS TOILET SUITEVB VANITY BASINWM WASHING MACHINEWO WALL OVEN
NOTESN1:ALL DIMENSIONS TO BE CHECK AND VERIFIED ON SITE.DO NOT SCALE FROM DRAWINGSN2:CONTRACTOR TO OBTAIN DERBYSHIRE'S PRIOR WRITTENAPPROVAL FOR ANY EXTRA WORK OR ALTERATIONS TOAPPROVED DRAWINGSN3:A FULL SET OF LAMINATED DRAWINGS ANDSPECIFICATIONS TO BE KEPT ON SITE IN GOODCONDITION AT ALL TIMESN4:SHOULD DISCREPANCIES OR ERROR BE DISCOVERED ONTHE DRAWINGS OR SPECIFICATIONS, DERBYSHIRE MUSTBE NOTIFIED IMMEDIATELYN5:ALL BUILDING WORKS TO BE COMPLETED INACCORDANCE WITH THE NCC/BCA AND TO THESATISFACTION OF THE LOCAL AUTHORITY AND ORBUILDING SURVEYORN6:REFER TO DOOR & WINDOW SCHEDULES FOR COMPLETEDIMENSIONS & DETAILSN7:WATERPROOFING OF WET AREAS, BEING BATHROOMS,SHOWERS, SHOWER ROOMS, LAUNDRIES, SANITARYCOMPARTMENTS AND THE LIKE SHALL BE PROVIDED INACCORDANCE WITH AS3740-2010: WATERPROOFING OFDOMESTIC WET AREAS
J0 JOINERY NO.
XX MATERIAL
W0 WINDOW NO.
D0 DOOR NO.
20MM SLABSETDOWN TOGARAGE DOOR
GARAGE
1:100 @ A3
-
FFL 100.4
SITE BOUNDARY
SITE BOUNDARY
SIT
E B
OU
ND
AR
Y
SIT
E B
OU
ND
AR
Y
FFL 100.25
POST
COL.
COL.
COL.
COL.
EX
PO
SE
DA
GG
RE
GA
TE
CO
NC
RE
TE
EXPOSEDAGGREGATECONCRETE
INFILLPAVINGSLAB
SH
OW
ER
SE
TD
OW
N
SH
OW
ER
SE
TD
OW
N
Project No:
Drawn:
Date:
Revision:
Scale:
Drawing No:
Drawing:Project:
Torquay, VIC., 3228
ELEVATIONS SHT.114-66 15/12/2015
BA - A03 of 20
98 Pakington Street, Geelong West, Vic., 3218
T 5221 8409 F 5229 7433
www.derbyshire.com.au
ABN 80 060 577 648
Revisions:- - -
DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes
CONSTRUCTION
2,40
030
035
030
0
2,70
065
0
3,35
0
3,20
0
4,68
0
1,05
060
01,
550
W2 W1
D1RD1
W3
R.L. 100.40
R.L. 100.25
R.L. 102.95
R.L. 103.6
R.L. 103.6
R.L. 105.08
4,83
0
3,35
0
3,05
030
0
2,70
01,
200
3,90
0
W4D2
R.L. 100.40
R.L. 100.25
R.L. 102.95
R.L. 103.6
R.L. 103.33
R.L. 103.1
R.L. 104.3
W5
MATERIALS & FINISHES SCHEDULE:BW BRICKWORKCB COLORBOND ROOFINGSC SCYON 'MATRIX' CLADDING OR SIMILAR
REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH
ABBREVIATIONS:BC BARGE FLASHING & CAPPINGCOL STEEL COLUMNDP DOWNPIPE - COLOUR TO MATCH
ADJACENT WALL COLOUREXH EXHAUST DUCTFCL FINISHED CEILING LEVELFFL FINISHED FLOOR LEVELG SWINGING GATEGAS EXTERNAL GAS OUTLETIHW INSTANTANEOUS HOT WATERMB ELECTRICAL METERBOARDNGL NATURAL GROUND LINEOP OVERFLOW POPPC PARAPET CAPPINGRL RELATIVE LEVELRWT RAINWATER TANKRWH RAINWATER HEADSHR SHOWERSP SPREADER
NOTESN1:NCC 2014 BCA VOL 2ALL MATERIALS AND WORK PRACTICES SHALL COMPLYWITH, BUT NOT LIMITED TO THE BUILDING REGULATIONS2006, NATIONAL CONSTRUCTION CODE SERIES 2014BUILDING CODE OF AUSTRALIA VOL 2 AND ALL RELEVANTCURRENT AUSTRALIAN STANDARDS (AS AMENDED)REFERRED TO THEREIN. UNLESS OTHERWISE SPECIFIED,THE TERM NCC SHALL REFER TO NATIONALCONSTRUCTION CODE SERIES 2014 BUILDING CODE OFAUSTRALIA VOLUME 2.ALL MATERIALS AND CONSTRUCTION PRACTICE SHALLMEET THE PERFORMANCE REQUIREMENTS OF THE BCA.WHERE AN ALTERNATIVE SOLUTION IS PROPOSED THEN,PRIOR TO IMPLEMENTATION OR INSTALLATION, IT FIRSTMUST BE ASSESSED AND APPROVED BY THE RELEVANTBUILDING SURVEYOR AS MEETING THE PERFORMANCEREQUIREMENTS OF THE NCC.N2:GLAZING, INCLUDING SAFETY GLAZING, SHALL BEINSTALLED TO A SIZE, TYPE AND THICKNESS SO AS TOCOMPLY WITH:- BCA PART 3 FOR CLASS 1 AND 10BUILDINGS WITHIN A DESIGN WIND SPEED OF NOT MORETHAN N3; AND - NCC 2014 BCA VOL 1 PART B1.4 FORCLASS 2 AND 9 BUILDINGS.N3:THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHANY HOUSE ENERGY RATING (HERS) REPORT AND SHALLBE CONSTRUCTED IN ACCORDANCE WITH THE STAMPEDPLANS ENDORSED BY THE ACCREDITED THERMALPERFORMANCE ASSESSOR WITHOUT ALTERATIONN4:WHERE REQUIRED TREAT AREA BENEATH FLOOR AGAINSTTERMITE INFESTATION IN ACCORDANCE WITH RELEVANTSTANDARD. CONTACT THE RELEVANT MUNICIPAL COUNCILTO DETERMINE IF THIS IS MANDATORYN5:REFER SCHEDULES FOR DIMENSIONED DOOR & WINDOWELEVATIONS. WINDOW SIZES NOMINATED ARE NOMINALONLY. ACTUAL SIZES MAY VARY ACCORDING TOMANUFACTURERN6:STEPS TO DECK AS REQUIRED. 190MM MAX. RISER.250MM MIN. GOING TREADS
3,20
0
4,68
0
1,05
060
01,
550
W2 W1
D1
W3
R.L. 103.6
R.L. 105.08
4,83
0
3,35
0
3,05
030
0
2,70
01,
200
3,90
0
W4D2
R.L. 100.40
R.L. 100.25
R.L. 102.95
R.L. 103.6
R.L. 103.33
R.L. 103.1
R.L. 104.3
W5
SOUTH ELEVATION1:100E/1
WEST ELEVATION1:100E/2
MOTORISED STEELLINE SECTIONAL DOOR.COLORBOND FINISH.
ENTRYALUMINIUM &GLAZEDPIVOT DOOR
BARGEFLASHING
PARAPETCAPPING
POWDERCOATALUMINIUMWINDOWS
BRICKWORK
N.G.L.
MATRIXCLADDING
BUILDINGENVELOPE LINE
BUILDINGENVELOPE LINE
BUILDINGENVELOPE LINE
SPOTTED GUM TIMBER SCREEN.90MM X 32MM. 64MM GAPS.90X32MM BOTTOM PLATE FIXEDTO STEEL SADDLE PLATES150MM ABOVE CONCRETEFOOTING.
RENDERED50MM FOAM
PARAPETCAPPING
SOFFIT LININGRAKED 4.5MMHARDIFLEX WITHEXPRESSED JOINTS.
BARGEFLASHING
FASCIAGUTTER
COLORBONDROOFSHEETING
POWDERCOATALUMINIUMWINDOWS
COLORBONDCORRUGATEDMETAL SHEETCLADDING
SPOTTEDGUM TIMBER
SCREEN
RENDEREDBRICKWORK POST
COLORBONDCORRUGATEDMETAL SHEETCLADDING
SPOTTED GUM TIMBER SCREEN.90MM X 32MM. 64MM GAPS.90X32MM BOTTOM PLATE FIXEDTO STEEL SADDLE PLATES150MM ABOVE CONCRETEFOOTING.
N.G.L.
BRICKPARAPET .
RENDEREDFINISH
BRICKWORK
DOUBLE BRICK.RENDERED
FINISH
DOUBLE BRICK.RENDERED
FINISH
HORIZONTALSUPPORT IFREQUIREDBEHIND.
DOUBLE BRICK.RENDERED
FINISH
DOWNPIPE DOWNPIPE DOWNPIPE
1:100 @ A3
SIT
E B
OU
ND
AR
Y
SIT
E B
OU
ND
AR
Y
SIT
E B
OU
ND
AR
Y
FALL 10 DEG.
NOTE: TIMBER SCREEN NOT SHOWN FOR CLARITY
NOTE: TIMBER SCREENS NOT SHOWN FOR CLARITY
A
Revisions:A W1 WIDTH REVISED 02.11.15
Project No:
Drawn:
Date:
Revision:
Scale:
Drawing No:
Drawing:Project:
Torquay, VIC., 3228
ELEVATIONS SHT.214-66 15/12/2015
BA - A04 of 20
98 Pakington Street, Geelong West, Vic., 3218
T 5221 8409 F 5229 7433
www.derbyshire.com.au
ABN 80 060 577 648
Revisions:- - -
DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes
CONSTRUCTION
2,10
0
2,10
030
030
0
2,70
01,
200
3,90
0
W7 D3
R.L. 104.3
R.L. 103.1
R.L. 100.4
W6
2,10
030
0
2,40
030
0
2,70
01,
200
2,70
0
2,70
01,
980
4,68
0
W10
W8W9
W7A
W12W13
W11
R.L. 105.08
R.L. 103.1
R.L. 100.4 R.L. 100.4
R.L. 104.3
MATERIALS & FINISHES SCHEDULE:BW BRICKWORKCB COLORBOND ROOFINGSC SCYON 'MATRIX' CLADDING OR SIMILAR
REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH
ABBREVIATIONS:BC BARGE FLASHING & CAPPINGCOL STEEL COLUMNDP DOWNPIPE - COLOUR TO MATCH
ADJACENT WALL COLOUREXH EXHAUST DUCTFCL FINISHED CEILING LEVELFFL FINISHED FLOOR LEVELG SWINGING GATEGAS EXTERNAL GAS OUTLETIHW INSTANTANEOUS HOT WATERMB ELECTRICAL METERBOARDNGL NATURAL GROUND LINEOP OVERFLOW POPPC PARAPET CAPPINGRL RELATIVE LEVELRWT RAINWATER TANKRWH RAINWATER HEADSHR SHOWERSP SPREADER
NOTESN1:NCC 2014 BCA VOL 2ALL MATERIALS AND WORK PRACTICES SHALL COMPLYWITH, BUT NOT LIMITED TO THE BUILDING REGULATIONS2006, NATIONAL CONSTRUCTION CODE SERIES 2014BUILDING CODE OF AUSTRALIA VOL 2 AND ALL RELEVANTCURRENT AUSTRALIAN STANDARDS (AS AMENDED)REFERRED TO THEREIN. UNLESS OTHERWISE SPECIFIED,THE TERM NCC SHALL REFER TO NATIONALCONSTRUCTION CODE SERIES 2014 BUILDING CODE OFAUSTRALIA VOLUME 2.ALL MATERIALS AND CONSTRUCTION PRACTICE SHALLMEET THE PERFORMANCE REQUIREMENTS OF THE BCA.WHERE AN ALTERNATIVE SOLUTION IS PROPOSED THEN,PRIOR TO IMPLEMENTATION OR INSTALLATION, IT FIRSTMUST BE ASSESSED AND APPROVED BY THE RELEVANTBUILDING SURVEYOR AS MEETING THE PERFORMANCEREQUIREMENTS OF THE NCC.N2:GLAZING, INCLUDING SAFETY GLAZING, SHALL BEINSTALLED TO A SIZE, TYPE AND THICKNESS SO AS TOCOMPLY WITH:- BCA PART 3 FOR CLASS 1 AND 10BUILDINGS WITHIN A DESIGN WIND SPEED OF NOT MORETHAN N3; AND - NCC 2014 BCA VOL 1 PART B1.4 FORCLASS 2 AND 9 BUILDINGS.N3:THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHANY HOUSE ENERGY RATING (HERS) REPORT AND SHALLBE CONSTRUCTED IN ACCORDANCE WITH THE STAMPEDPLANS ENDORSED BY THE ACCREDITED THERMALPERFORMANCE ASSESSOR WITHOUT ALTERATIONN4:WHERE REQUIRED TREAT AREA BENEATH FLOOR AGAINSTTERMITE INFESTATION IN ACCORDANCE WITH RELEVANTSTANDARD. CONTACT THE RELEVANT MUNICIPAL COUNCILTO DETERMINE IF THIS IS MANDATORYN5:REFER SCHEDULES FOR DIMENSIONED DOOR & WINDOWELEVATIONS. WINDOW SIZES NOMINATED ARE NOMINALONLY. ACTUAL SIZES MAY VARY ACCORDING TOMANUFACTURERN6:STEPS TO DECK AS REQUIRED. 190MM MAX. RISER.250MM MIN. GOING TREADS
W6
NORTH ELEVATION1:100E/3
EAST ELEVATION1:100E/4
BUILDINGENVELOPE LINE
BARGEFLASHING
POWDERCOAT ALUMINIUMWINDOWS. BUTT GLAZEDCORNER WINDOW
N.G.L.
SPOTTED GUM TIMBER SCREEN.90MM X 32MM. 64MM GAPS.90X32MM BOTTOM PLATE FIXEDTO STEEL SADDLE PLATES150MM ABOVE CONCRETEFOOTING.
DOUBLEBRICK.RENDEREDFINISH
N.G.L.
FASCIAGUTTER
COLORBONDROOFSHEETING
RIDGECAPPING
50MMRENDEREDFOAM
BUILDINGENVELOPE LINE
50MMRENDEREDFOAM
BARGEFLASHING
BUILDINGENVELOPE LINE
POWDERCOATALUMINIUMSLIDING DOORS
POWDERCOATALUMINIUMWINDOWS
COLORBONDCORRUGATEDMETAL SHEETCLADDING
FASCIAGUTTER
FASCIAGUTTER
BRICKWORK
COLORBONDCORRUGATEDMETAL SHEET
CLADDING
COLORBONDCORRUGATEDMETAL SHEET
CLADDING
BRICKWORK
COLORBONDCORRUGATEDMETAL SHEETCLADDING
HOT WATERSERVICE TAPELECTRICAL
METERBOARDTELSTRAGASMETER
SOLARPANELS
600X600MMACCESSHATCH.
BLUEBOARD
COLORBONDCORRUGATEDMETAL SHEETCLADDING
EVAPCOOLER
CONFIRM EXTERNALEXPOSED AGG. SLAB
RL'S ON SITE.
1:100 @ A3
SIT
E B
OU
ND
AR
Y
SIT
E B
OU
ND
AR
Y
SIT
E B
OU
ND
AR
Y
NOTE: TIMBER SCREEN NOT SHOWN FOR CLARITY
Revisions:A W11 POSITION MOVED 15.12.15
A
Project No:
Drawn:
Date:
Revision:
Scale:
Drawing No:
Drawing:Project:
Torquay, VIC., 3228
REFLECTED CEILINGPLAN
14-66 15/12/2015
BA - A05 of 20
98 Pakington Street, Geelong West, Vic., 3218
T 5221 8409 F 5229 7433
www.derbyshire.com.au
ABN 80 060 577 648
Revisions:- - -
DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes
CONSTRUCTION
M.H
.
1,220905,8351203,590902,020903,420902,120902,63090
11020,185
1,9202,0591,8561,0821,8561,9828991,0507101,7228398991,8611,200360
1,200110
10,620240
1,070
1,9201,300
3,6142,662
899576
1,22090
4,230120
1,53090
4,65090
1,220
90 500230
6,080 90 3,620 90 1,800 90 7,315 90 1,220
7,140 1,153 1,722 3,384 1,856 2,839 2,050
2404,260
90
2,2504,590
1,5306,630
2,35090
1,820
6,990 150 12,765 240 1,070
920901,62090
2,710901,190610902,9109062090
1002,4263,1432,432
2,43290
100
7,370 20,145 5,485
2,38010,970
1,650
5,61520,2957,090
2306,170
230
906,300
240
2302,375
901,895
S/2A09
S/4A11
S/3A10
S/1A08
MATERIALS & FINISHES SCHEDULE
MR MOISTURE RESISTANT PLASTERBOARDPB PLASTERBOARD. PAINT FINISHPB3 RAKED PLASTERBOARD CEILING. PAINT FINISH.PB4 INTERNAL PLASTERBOARD BULKHEADVB1 SOFFIT LINING SHEETING
REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH
ABBREVIATIONS:B BULKHEADCH CEILING HEIGHT FROM FINISHED FLOOR LEVELEXH EXHAUST DUCT AS SPEC.FCL FINISHED CEILING LEVELRL RELATIVE LEVEL
XX MATERIAL
NOTESN1:ALL CEILING AREAS TO BE SQUARE SET UNLESS NOTEDOTHERWISEN2:ALL BULKHEADS TO BE SQUARE SET TO CEILING PLANESN3:ALL CEILING HEIGHTS AS NOMINATED ON PLANSN4:REFER TO ELECTRICAL PLANS FOR LIGHTINGINFORMATION
1:100 @ A3
GARAGE
PLASTERBOARDCEILING 2700MM HIGH
COVED CORNICE
BED 2
BED 3MASTER BED BATHWIRENS LIVING
DININGKITCHENL'DRY
ENTRY
RO
BE
PASSAGE
FLUSH PLASTERBOARDCEILING 2700MM HIGHSQUARE SET CORNICE
FLUSH PLASTERBOARDCEILING 2700MM HIGHSQUARE SET CORNICE
FLUSH PLASTERBOARDCEILING 2700MM HIGHSQUARE SET CORNICE
2400
MM
HIG
HC
OV
ED
CO
RN
ICE
2400MM HIGHCOVED CORNICE
MR PLASTER2700MM HIGH
FLUSH PLASTERBOARDCEILING 2700MM HIGHSQUARE SET CORNICE
MR PLASTER2700MM HIGH
FLUSH PLASTERBOARDCEILING 2700MM HIGHSQUARE SET CORNICE
FLUSH PLASTERBOARDCEILING 2700MM HIGHSQUARE SET CORNICE
MRPLASTER2700MM
HIGH
RAKED P'BOARDCEILING
SQUARE SET CORNICE
FLUSH PLASTERBOARDCEILING 2700MM HIGHSQUARE SET CORNICE
FAL
L10
DE
G.
(ROOF SOFFIT LINE)
RO
OF
SO
FF
IT L
INE FA
LL
10 D
EG
.FA
LL
10 D
EG
.
RA
KE
D 4
.5M
MH
AR
DIF
LEX
WIT
HE
XP
RE
SS
ED
JO
INT
S
FAL
L10
DE
G.
RAKED 4.5MM HARDIFLEXWITH EXPRESSED JOINTS
RA
KE
D 4
.5M
MH
AR
DIF
LEX
WIT
HE
XP
RE
SS
ED
JO
INT
S
RO
OF
SO
FF
IT L
INE
ROOF SOFFIT LINE
4.5MM HARDIEFLEX
4.5M
M H
AR
DIE
FLE
X BULKHEAD
BU
LKH
EA
D
BU
LKH
EA
D
FAL
L10
DE
G.
BU
LKH
EA
D
VILLABOARDTO WALLS
VILLABOARDTO WALLS
VILLABOARDTO WALLS
RA
KE
D 4
.5M
MH
AR
DIF
LEX
WIT
HE
XP
RE
SS
ED
JO
INT
S
Project No:
Drawn:
Date:
Revision:
Scale:
Drawing No:
Drawing:Project:
Torquay, VIC., 3228
ELECTRICAL PLAN14-66 15/12/2015
BA - A06 of 20
98 Pakington Street, Geelong West, Vic., 3218
T 5221 8409 F 5229 7433
www.derbyshire.com.au
ABN 80 060 577 648
Revisions:- - -
DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes
CONSTRUCTION
D
F
W
DW
D
F
1
2
W
22
44
22
22
22
11
11
11
22
1 2
2
2
2
2
2
22
SD
SD
EF
EF
M.H
.
2
2
EC
EC
EC
EC
EC
EC
EC
DH
DH
DH
DH
DH
DH
DH
DH
M
PL1
FF
TL
PL2
PL2
TL
PL3
PL3
1,220905,8351203,590902,020903,420902,120902,63090
11020,185
1,9202,0591,8561,0821,8561,9828991,0507101,7228398991,8611,200360
1,200110
10,620240
1,070
1,9201,300
3,6142,662
899576
1,22090
4,230120
1,53090
4,65090
1,220
90 500230
6,080 90 3,620 90 1,800 90 7,315 90 1,220
7,140 1,153 1,722 3,384 1,856 2,839 2,050
2404,260
90
2,2504,590
1,5306,630
2,35090
1,820
6,990 150 12,765 240 1,070
920901,62090
2,710901,190610902,9109062090
1002,4263,1432,432
2,43290
100
7,370 20,145 5,485
2,38010,970
1,650
5,61520,2957,090
2306,170
230
906,300
240
2302,375
901,895
FO
XT
V
PH
TV
TV
E2
DL
ED
LE
DL
ED
L
ED
L DL
DL
DL
DL
DL
DL
DL
DL
DL
DL
DL
DL
DL
DL
DL
DL
DL
DL
DL
DL
DL
DL
ED
L
ED
LE
DL
ED
LE
DL
ED
L
ED
L
ED
L
ED
L
DL
DL
DL
DL
DL
DL
DL
DL
ED
LE
DL
FL
FL
DL
DL
ELECTRICAL LEGEND GF2D
DH
DL
EC
EDL
EF
FL
1
2
E2
4
M
TL
ID1G
2G
3G
4G
D
DH
DL
EC
EDL
EF
F
FL
FOX
GPO1
GPO2
GPO2E
GPO4
MS
PH
PL1
PL2
PL3
SD
TL
TV
ITEM1 GANG SWITCH
2 GANG SWITCH
3 GANG SWITCH
4 GANG SWITCH
DATA POINT - CAT6
DUCTED HEATING POINT
LED DOWNLIGHT
EVAP COOLING POINT
EXTERNAL LED DOWNLIGHT
CEILING EXHAUST FAN
FLUORESCENT
FLOOD LIGHT WITH SENSOR
FOXTEL POINT
SINGLE GPO
DOUBLE GPO
DOUBLE GPO EXTERNAL
FOUR GPO
MOTION SENSOR
PHONE POINT
ENTRY PENDANT LIGHT
DINING PENDANT LIGHT. CLIENTSUPPLY.
PENDANT LIGHT
SMOKE DETECTOR
TASTIC LIGHT
TELEVISION POINT
No.5
3
2
4
2
8
33
7
15
2
2
2
1
8
21
1
2
1
1
1
2
2
2
2
3
NOTESN1:PROVIDE POWER FOR:KITCHEN- DISHWASHER- OVEN- RANGEHOOD- REFRIGERATOR- COOKTOPN2:ALL LIGHT FITTINGS & LAMPS SHOWN ARE ENERGYEFFICIENT. ANY CHANGE TO NUMBER OF OR LAMPENERGY OUTPUT MUST BE RE-EVALUATED FOR OVERALLCOMPLIANCE OF NCC/BCA PART 3.12.5.4.N3:ALL INTERNAL LIGHTS ARE SURFACE MOUNTED UNLESSOTHERWISE NOTED. NOTE: THE R VALUE OF THE CEILINGINSULATION MUST BE INCREASED WHERE CEILINGINSULATION IS REMOVED AROUND DOWN LIGHTS ANDEXHAUST FANS AS PER THE BCA TABLE 3.12.1.1A.N4:ALL FOR INDUSTRY APPROVED DOWNLIGHT COVERS FORINSULATION PROTECTION AND DRAFT SEALING(EXAMPLE: IGLOO RECESSED DOWNLIGHT COVER)N5:ALL EXTERNAL LIGHT FITTINGS ARE TO BE MARINE GRADEAND BE CONTROLLED BY DAYLIGHT MOTION SENSORS.N6:SMOKE ALARMS TO BE PROVIDED AND INSTALLED INACCORDANCE WITH AS3786. NEW DWELLINGS ANDADDITIONS WITH SLEEPING ACCOMMODATION TO BEHARD WIRED WITH BATTERY BACK UP.
ABBREVIATIONS:1050 DENOTES HEIGHT TO CENTRELINE OF GPO
FROM FFL2W 2 WAY LIGHT SWITCHA ARCHITRAVE MOUNTED LIGHT SWITCHD DIMMABLE SWITCH
WIRING
1:100, 1:1 @ A3
WATTAGETOTAL WATTAGE - 1,039 W
WATTAGE PER M2 - DESIGN AVERAGE INTERNAL 4.08 W/M2 (747W/182.66M2), VERANDAH OR BALCONY 4.0 W/M2(180W/44.75M2) & GARAGE 2.9 W/M2 (112W/38.304M2).
ALLOWABLE WATTAGE - INTERNAL 5W/M2, VERANDAH ORBALCONY 4W/M2 & GARAGE 3.0W/M2).
GARAGE BED 2
BED 3MASTER BED BATHWIRENS LIVING
DININGKITCHENL'DRY
ENTRY PASSAGE
M/BGAS T
2W
2W
2W
2W
2W
2W
2W
2W
CONDUIT INSLABDUCTED
HEATINGUNTIT
Project No:
Drawn:
Date:
Revision:
Scale:
Drawing No:
Drawing:Project:
Torquay, VIC., 3228
ROOF PLAN14-66 15/12/2015
BA - A07 of 20
98 Pakington Street, Geelong West, Vic., 3218
T 5221 8409 F 5229 7433
www.derbyshire.com.au
ABN 80 060 577 648
Revisions:- - -
DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes
CONSTRUCTION
E/3A04
E/4A04
E/1A03
E/2A03 S/2
A09
S/4A11
S/3A10
S/1A08
NOTESN1:THE LOCATION OF ALL ROOF EQUIPMENT TO BE VERIFIEDON SITE PRIOR TO INSTALLATIONN2:CONNECT DOWNPIPES TO RAINWATER TANK.STORMWATER OVERFLOW TO BE TAKEN TO THE LEGALPOINT OF DISCHARGE TO THE RELEVANT AUTHORITIESAPPROVAL.N3:INSTALL ALL FLASHINGS AND CAPPING'S AS NECESSARYTO ENSURE COMPLETE ROOF WATER TIGHTNESS.N4:REFER TO INTRAX ENGINEERS DOCUMENTATION FORCOMPLETE STORMWATER DESIGNN5:DEKTITE FLASHING TO ROOF PENETRATIONSN6:BOX GUTTER SIZE 400MM X 100MM DEEP MINIMUM.INTRAX TO CHECK & CONFIRM. 1:100 FALL MIN.N7:COLORBOND PARAPET CAPPING TO FALL INWARDS. ONSLOPING HW BATTEN FIZED TO TOP OF WALL STRUCTURE
MATERIALS & FINISHES SCHEDULE
CB COLORBOND CORRUGATED ROOFING
REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH
ABBREVIATIONS:AER ROOF ANTENNABC BARGE FLASHING & CAPPINGBG BOX GUTTERCC COLORBOND CAPPINGDP DOWNPIPEFC FASCIA CAPPINGFG FASCIA GUTTERFWB FEATURE WINDOW BOXING - ALUMINIUMGSP 250X250MM GRATED S.W. PITSOP OVERFLOW POPPC PARAPET CAPPINGRL RELATIVE LEVELSG SOAKER GUTTERSPR SPREADERRWH RAIN WATER HEADWRF WALL / ROOF FLASHING
XX MATERIAL
FG
CB BC
RC
CB
FG
CB
BC
FG
CB
RC
CB
FG
CB
FG
RC
PC
BC
BC
BGBC
BC
PC
WRFWRFPC
FG
FG
BC
WRF
COLORBOND FLAT SHEET OVER PLY. FALL TOWALL. FORM GUTTER OUT OF SHEET & FALLTO DP.
1:100 @ A3
FAL
L10
º
(WALL BELOW)
(WA
LL B
ELO
W)
(WALL BELOW)
RWHDP &OP
(SITE BOUNDARY)
FAL
L10
º
DP
DP DP
DPDPDP
(WALL BELOW)
FAL
L1.
5º
FAL
L10
ºFA
LL
10º
FAL
L10
º
(GARAGE WALL BELOW)
(WALL BELOW)
CHECKSOLAR HWS OR RAINWATER TANK
RO
OF
ST
EP
SOLAR PANELS
GSP
GSP GSP
GSP
LPOD TO KERB.REFER COGG
DETAILS
EVAPCOOLER
Project No:
Drawn:
Date:
Revision:
Scale:
Drawing No:
Drawing:Project:
Torquay, VIC., 3228
SECTION 114-66 15/12/2015
BA - A08 of 20
98 Pakington Street, Geelong West, Vic., 3218
T 5221 8409 F 5229 7433
www.derbyshire.com.au
ABN 80 060 577 648
Revisions:- - -
DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes
CONSTRUCTION
3,10
0
2,70
040
0
2,70
01,
480
4,18
0
2,70
0
RD2
D4
R.L. 100.40
R.L. 100.25
R.L. 102.95
R.L. 105.08
R.L. 100.40
R.L. 103.10
MATERIALS & FINISHES SCHEDULE:CA1 CARPETCB COLORBOND SHEET ROOFINGCC COVED CORNICECOS CONCRETE SLABMDF PAINTED MDFMR MOISTURE RESISTANT PLASTERBOARDPB PLASTERBOARD PAINT FINISHSK1 TIMBER SKIRTINGTD TIMBER DECKINGVB1 SOFFIT LINING SHEETING
REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH
ABBREVIATIONS:B BULKHEADBC BARGE FLASHING & CAPPINGCOL STEEL COLUMNDP DOWNPIPEEXH EXHAUST DUCTFCL FINISHED CEILING LEVELFFL FINISHED FLOOR LEVELG SWINGING GATEGAS EXTERNAL GAS OUTLETIHW INSTANTANEOUS HOT WATERMB ELECTRICAL METERBOARDNGL NATURAL GROUND LINEOP OVERFLOW POPPC PARAPET CAPPINGRL RELATIVE LEVELRWT RAINWATER TANKRWH RAINWATER HEADSHR SHOWERSP SPREADER
NOTESN1:THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANYSTRUCTURAL OR CIVIL ENGINEERING COMPUTATIONSAND DRAWINGS; AND ALL OTHER CONSULTANTSDRAWINGS / DETAILS AND WITH ANY OTHER WRITTENINSTRUCTIONS ISSUED IN THE COURSE OF THECONTRACT.N2:GLAZING, INCLUDING SAFETY GLAZING, SHALL BEINSTALLED TO A SIZE, TYPE AND THICKNESS SO AS TOCOMPLY WITH:- BCA PART 3 FOR CLASS 1 AND 10BUILDINGS WITHIN A DESIGN WIND SPEED OF NOT MORETHAN N3; AND - NCC 2014 BCA VOL 1 PART B1.4 FORCLASS 2 AND 9 BUILDINGS.N3:THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHANY HOUSE ENERGY RATING (HERS) REPORT AND SHALLBE CONSTRUCTED IN ACCORDANCE WITH THE STAMPEDPLANS ENDORSED BY THE ACCREDITED THERMALPERFORMANCE ASSESSOR WITHOUT ALTERATIONN4:WHERE REQUIRED TREAT AREA BENEATH FLOOR AGAINSTTERMITE INFESTATION IN ACCORDANCE WITH RELEVANTSTANDARD. CONTACT THE RELEVANT MUNICIPAL COUNCILTO DETERMINE IF THIS IS MANDATORYN5:REFER TO SCHEDULES FOR DIMENSIONED DOOR &WINDOW ELEVATIONS. WINDOW SIZES NOMINATED ARENOMINAL ONLY. ACTUAL SIZES MAY VARY ACCORDING TOMANUFACTURERN6:STEPS TO DECK. 190MM MAX. RISER. 250MM MIN. GOINGTREADSN8:REFER TO STRUCTURAL ENGINEERING DOCUMENTS FORFOOTINGS & SLAB SPECIFICATION, FLOOR & WALLFRAMING.N9:REFER TO ENERGY REPORT FOR NOMINATION OF ALLINSULATION.
SECTION 11:50S/1
CONCRETE
COVED CORNICETO GARAGE
10MM FLUSH P'BOARD TO U/SOF 70X25MM MPG10 BATTENOR MPG10 TOPHAT BATTENSAT 450CTS MAX. FRAME OUT
CEILING AS REQUIRED TOACHIEVE 2700MM HEIGHT.
COLORBOND WALL /ROOF FLASHING
PROVIDE INSULATIONTO EXTERNAL WALLS
AS PERSPECIFICATIONS
COLORBOND PARAPETCAPPING TO FALL
INWARDS ON SLOPINGH.W. BATTEN FIXED TO
TOP OF WALL STRUCTURE
PROVIDE 300MM W x 150MM DCOLORBOND BOX GUTTER @1:100MM FALL ON SPANDECKGUTTER SUPPORT SYSTEM
COLORBONDROOF SHEETING ASSPECIFIED
SLAB & CONCRETEFOOTINGS TO STRUCTURALENGINEERS DETAILS
10MMPLASTERBOARDWALL LINING TO90MM STUD WALL
SELECTEDSKIRTING
COLORBOND ROOFSHEETING, SARKING ANDFLASHING AS REQUIRED TORENDER ROOF WATERTIGHT
INSULATION BATTS TOROOF AS PERSPECIFICATION
FASCIAGUTTER
CARPET
COLORBONDCORRUGATED METAL
SHEET CLADDING
SELECTEDARCHITRAVES
RAKEDPLASTERBOARDCEILING
PREFABRICATED ROOFTRUSS @ 600MM CENTRESAS PER MANUFACTURERSSPECIFICATIONS
RAKED 4.5MMHARDIEFLEX
CEMENT SHEET
BRICKWORK
NGL
BARGE CAPPING
BRICKWORK
POWDERCOATALUMINIUMWINDOWS
BUILDINGENVELOPE LINE
BUILDINGENVELOPE LINE
PREFABRICATED ROOFTRUSS @ 600MM CENTRESAS PER MANUFACTURERSSPECIFICATIONS
1:50 @ A3
FALL 1.5 DEG.
GARAGE6MM VILLABOARD TOGARAGE
FALL 10 DEG.
ENTRY WIR
SIT
E B
OU
ND
AR
Y
SIT
E B
OU
ND
AR
Y
Project No:
Drawn:
Date:
Revision:
Scale:
Drawing No:
Drawing:Project:
Torquay, VIC., 3228
SECTION 214-66 15/12/2015
BA - A09 of 20
98 Pakington Street, Geelong West, Vic., 3218
T 5221 8409 F 5229 7433
www.derbyshire.com.au
ABN 80 060 577 648
Revisions:- - -
DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes
CONSTRUCTION
2,70
01,
200
3,90
0
2,10
060
0
2,70
0
D7W4
R.L. 100.40
R.L. 103.1
R.L. 104.3
MATERIALS & FINISHES SCHEDULE:CA1 CARPETCB COLORBOND SHEET ROOFINGCC COVED CORNICECOS CONCRETE SLABMDF PAINTED MDFMR MOISTURE RESISTANT PLASTERBOARDPB PLASTERBOARD PAINT FINISHSK1 TIMBER SKIRTINGTD TIMBER DECKINGVB1 SOFFIT LINING SHEETING
REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH
ABBREVIATIONS:B BULKHEADBC BARGE FLASHING & CAPPINGCOL STEEL COLUMNDP DOWNPIPEEXH EXHAUST DUCTFCL FINISHED CEILING LEVELFFL FINISHED FLOOR LEVELG SWINGING GATEGAS EXTERNAL GAS OUTLETIHW INSTANTANEOUS HOT WATERMB ELECTRICAL METERBOARDNGL NATURAL GROUND LINEOP OVERFLOW POPPC PARAPET CAPPINGRL RELATIVE LEVELRWT RAINWATER TANKRWH RAINWATER HEADSHR SHOWERSP SPREADER
NOTESN1:THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANYSTRUCTURAL OR CIVIL ENGINEERING COMPUTATIONSAND DRAWINGS; AND ALL OTHER CONSULTANTSDRAWINGS / DETAILS AND WITH ANY OTHER WRITTENINSTRUCTIONS ISSUED IN THE COURSE OF THECONTRACT.N2:GLAZING, INCLUDING SAFETY GLAZING, SHALL BEINSTALLED TO A SIZE, TYPE AND THICKNESS SO AS TOCOMPLY WITH:- BCA PART 3 FOR CLASS 1 AND 10BUILDINGS WITHIN A DESIGN WIND SPEED OF NOT MORETHAN N3; AND - NCC 2014 BCA VOL 1 PART B1.4 FORCLASS 2 AND 9 BUILDINGS.N3:THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHANY HOUSE ENERGY RATING (HERS) REPORT AND SHALLBE CONSTRUCTED IN ACCORDANCE WITH THE STAMPEDPLANS ENDORSED BY THE ACCREDITED THERMALPERFORMANCE ASSESSOR WITHOUT ALTERATIONN4:WHERE REQUIRED TREAT AREA BENEATH FLOOR AGAINSTTERMITE INFESTATION IN ACCORDANCE WITH RELEVANTSTANDARD. CONTACT THE RELEVANT MUNICIPAL COUNCILTO DETERMINE IF THIS IS MANDATORYN5:REFER TO SCHEDULES FOR DIMENSIONED DOOR &WINDOW ELEVATIONS. WINDOW SIZES NOMINATED ARENOMINAL ONLY. ACTUAL SIZES MAY VARY ACCORDING TOMANUFACTURERN6:STEPS TO DECK. 190MM MAX. RISER. 250MM MIN. GOINGTREADSN8:REFER TO STRUCTURAL ENGINEERING DOCUMENTS FORFOOTINGS & SLAB SPECIFICATION, FLOOR & WALLFRAMING.N9:REFER TO ENERGY REPORT FOR NOMINATION OF ALLINSULATION.
SECTION 21:50S/2
COLORBOND ROOFSHEETING, SARKING ANDFLASHING AS REQUIRED TORENDER ROOF WATERTIGHT
INSULATION BATTS TOROOF AS PER
SPECIFICATION
FASCIAGUTTER
PREFABRICATED ROOFTRUSS @ 600MM CENTRESAS PER MANUFACTURERSSPECIFICATIONS
COLORBONDCORRUGATED METALSHEET CLADDING
RIDGECAPPING
PROVIDE INSULATIONTO EXTERNAL WALLSAS PERSPECIFICATIONS
SLAB & CONCRETEFOOTINGS TO STRUCTURALENGINEERS DETAILS
NGL
FASCIAGUTTER
POWDERCOATALUMINIUM
WINDOWS
DOWNPIPE10MMPLASTERBOARDWALL LINING TO90MM STUD WALL
SELECTEDSKIRTING
FLUSHPLASTERBOARD
SELECTEDARCHITRAVES
FLUSH MOISTURERESISTANT
PLASTERBOARD
TILES
BUILDINGENVELOPE LINE
BUILDINGENVELOPE LINE
DOWNPIPE
COLORBONDCORRUGATEDMETAL SHEET
CLADDING
HOT WATER SERVICE
SOLAR PANELS
EXPOSEDAGGREGATE
CONCRETE
1:50 @ A3
BED 2 PASS. BATH
SIT
E B
OU
ND
AR
Y
SIT
E B
OU
ND
AR
Y
FALL 10 DEG. FALL 10 DEG.
Project No:
Drawn:
Date:
Revision:
Scale:
Drawing No:
Drawing:Project:
Torquay, VIC., 3228
SECTION 314-66 15/12/2015
BA - A10 of 20
98 Pakington Street, Geelong West, Vic., 3218
T 5221 8409 F 5229 7433
www.derbyshire.com.au
ABN 80 060 577 648
Revisions:- - -
DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes
CONSTRUCTION
300
300
2,10
0
2,09
860
2
2,70
0
W6
R.L. 100.40
R.L. 103.1
R.L. 104.3
MATERIALS & FINISHES SCHEDULE:CA1 CARPETCB COLORBOND SHEET ROOFINGCC COVED CORNICECOS CONCRETE SLABMDF PAINTED MDFMR MOISTURE RESISTANT PLASTERBOARDPB PLASTERBOARD PAINT FINISHSK1 TIMBER SKIRTINGTD TIMBER DECKINGVB1 SOFFIT LINING SHEETING
REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH
ABBREVIATIONS:B BULKHEADBC BARGE FLASHING & CAPPINGCOL STEEL COLUMNDP DOWNPIPEEXH EXHAUST DUCTFCL FINISHED CEILING LEVELFFL FINISHED FLOOR LEVELG SWINGING GATEGAS EXTERNAL GAS OUTLETIHW INSTANTANEOUS HOT WATERMB ELECTRICAL METERBOARDNGL NATURAL GROUND LINEOP OVERFLOW POPPC PARAPET CAPPINGRL RELATIVE LEVELRWT RAINWATER TANKRWH RAINWATER HEADSHR SHOWERSP SPREADER
NOTESN1:THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANYSTRUCTURAL OR CIVIL ENGINEERING COMPUTATIONSAND DRAWINGS; AND ALL OTHER CONSULTANTSDRAWINGS / DETAILS AND WITH ANY OTHER WRITTENINSTRUCTIONS ISSUED IN THE COURSE OF THECONTRACT.N2:GLAZING, INCLUDING SAFETY GLAZING, SHALL BEINSTALLED TO A SIZE, TYPE AND THICKNESS SO AS TOCOMPLY WITH:- BCA PART 3 FOR CLASS 1 AND 10BUILDINGS WITHIN A DESIGN WIND SPEED OF NOT MORETHAN N3; AND - NCC 2014 BCA VOL 1 PART B1.4 FORCLASS 2 AND 9 BUILDINGS.N3:THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHANY HOUSE ENERGY RATING (HERS) REPORT AND SHALLBE CONSTRUCTED IN ACCORDANCE WITH THE STAMPEDPLANS ENDORSED BY THE ACCREDITED THERMALPERFORMANCE ASSESSOR WITHOUT ALTERATIONN4:WHERE REQUIRED TREAT AREA BENEATH FLOOR AGAINSTTERMITE INFESTATION IN ACCORDANCE WITH RELEVANTSTANDARD. CONTACT THE RELEVANT MUNICIPAL COUNCILTO DETERMINE IF THIS IS MANDATORYN5:REFER TO SCHEDULES FOR DIMENSIONED DOOR &WINDOW ELEVATIONS. WINDOW SIZES NOMINATED ARENOMINAL ONLY. ACTUAL SIZES MAY VARY ACCORDING TOMANUFACTURERN6:STEPS TO DECK. 190MM MAX. RISER. 250MM MIN. GOINGTREADSN8:REFER TO STRUCTURAL ENGINEERING DOCUMENTS FORFOOTINGS & SLAB SPECIFICATION, FLOOR & WALLFRAMING.N9:REFER TO ENERGY REPORT FOR NOMINATION OF ALLINSULATION.
SECTION 31:50S/3
COLORBOND ROOFSHEETING, SARKING ANDFLASHING AS REQUIRED TORENDER ROOF WATERTIGHT
INSULATION BATTS TOROOF AS PER
SPECIFICATION
FASCIAGUTTER
PREFABRICATED ROOFTRUSS @ 600MM CENTRESAS PER MANUFACTURERSSPECIFICATIONS
COLORBONDCORRUGATED METALSHEET CLADDING
RIDGECAPPING
PROVIDEINSULATION TO
EXTERNALWALLS AS PER
SPECIFICATIONS
SLAB & CONCRETEFOOTINGS TOSTRUCTURAL
ENGINEERS DETAILS
NGL
FASCIAGUTTER
POWDERCOATALUMINIUM WINDOWS
10MMPLASTERBOARDWALL LINING TO90MM STUD WALL
SELECTEDSKIRTING
FLUSHPLASTERBOARD
SELECTEDARCHITRAVES
BUILDINGENVELOPE LINE
BUILDINGENVELOPE LINE
BRICKWORK
EXPOSEDAGGREGATECONCRETE
EXPOSEDAGGREGATE
CONCRETE
4.5MM HARDIEFLEX
COLORBOND FLAT SHEET OVERPLY. FALL TO WALL. FORMGUTTER OUT OF SHEET & FALLTO DP.
CONFIRM EXISTINGGROUND LEVELS ONSITE FOR EXPOSEDAGGREGATE SLAB.
50MMRENDEREDFOAM
1:50 @ A3
DINING LIVING
SIT
E B
OU
ND
AR
Y
SIT
E B
OU
ND
AR
Y
Project No:
Drawn:
Date:
Revision:
Scale:
Drawing No:
Drawing:Project:
Torquay, VIC., 3228
SECTION 4 SHT.114-66 15/12/2015
BA - A11 of 20
98 Pakington Street, Geelong West, Vic., 3218
T 5221 8409 F 5229 7433
www.derbyshire.com.au
ABN 80 060 577 648
Revisions:- - -
DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes
CONSTRUCTION
D5
W3
D7
D1 D4
R.L. 100.40
R.L. 103.1
R.L. 105.08
MATERIALS & FINISHES SCHEDULE:CA1 CARPETCB COLORBOND SHEET ROOFINGCC COVED CORNICECOS CONCRETE SLABMDF PAINTED MDFMR MOISTURE RESISTANT PLASTERBOARDPB PLASTERBOARD PAINT FINISHSK1 TIMBER SKIRTINGTD TIMBER DECKINGVB1 SOFFIT LINING SHEETING
REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH
ABBREVIATIONS:B BULKHEADBC BARGE FLASHING & CAPPINGCOL STEEL COLUMNDP DOWNPIPEEXH EXHAUST DUCTFCL FINISHED CEILING LEVELFFL FINISHED FLOOR LEVELG SWINGING GATEGAS EXTERNAL GAS OUTLETIHW INSTANTANEOUS HOT WATERMB ELECTRICAL METERBOARDNGL NATURAL GROUND LINEOP OVERFLOW POPPC PARAPET CAPPINGRL RELATIVE LEVELRWT RAINWATER TANKRWH RAINWATER HEADSHR SHOWERSP SPREADER
NOTESN1:THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANYSTRUCTURAL OR CIVIL ENGINEERING COMPUTATIONSAND DRAWINGS; AND ALL OTHER CONSULTANTSDRAWINGS / DETAILS AND WITH ANY OTHER WRITTENINSTRUCTIONS ISSUED IN THE COURSE OF THECONTRACT.N2:GLAZING, INCLUDING SAFETY GLAZING, SHALL BEINSTALLED TO A SIZE, TYPE AND THICKNESS SO AS TOCOMPLY WITH:- BCA PART 3 FOR CLASS 1 AND 10BUILDINGS WITHIN A DESIGN WIND SPEED OF NOT MORETHAN N3; AND - NCC 2014 BCA VOL 1 PART B1.4 FORCLASS 2 AND 9 BUILDINGS.N3:THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHANY HOUSE ENERGY RATING (HERS) REPORT AND SHALLBE CONSTRUCTED IN ACCORDANCE WITH THE STAMPEDPLANS ENDORSED BY THE ACCREDITED THERMALPERFORMANCE ASSESSOR WITHOUT ALTERATIONN4:WHERE REQUIRED TREAT AREA BENEATH FLOOR AGAINSTTERMITE INFESTATION IN ACCORDANCE WITH RELEVANTSTANDARD. CONTACT THE RELEVANT MUNICIPAL COUNCILTO DETERMINE IF THIS IS MANDATORYN5:REFER TO SCHEDULES FOR DIMENSIONED DOOR &WINDOW ELEVATIONS. WINDOW SIZES NOMINATED ARENOMINAL ONLY. ACTUAL SIZES MAY VARY ACCORDING TOMANUFACTURERN6:STEPS TO DECK. 190MM MAX. RISER. 250MM MIN. GOINGTREADSN8:REFER TO STRUCTURAL ENGINEERING DOCUMENTS FORFOOTINGS & SLAB SPECIFICATION, FLOOR & WALLFRAMING.N9:REFER TO ENERGY REPORT FOR NOMINATION OF ALLINSULATION.
SECTION 41:50S/4
COLORBOND ROOFSHEETING, SARKING ANDFLASHING AS REQUIRED TORENDER ROOF WATERTIGHT
INSULATION BATTS TOROOF AS PER
SPECIFICATION
PREFABRICATED ROOFTRUSS @ 600MM CENTRESAS PER MANUFACTURERSSPECIFICATIONS
SLAB & CONCRETEFOOTINGS TO STRUCTURALENGINEERS DETAILS
NGL
POWDERCOATALUMINIUM WINDOWS
SELECTEDSKIRTING
FLUSHPLASTERBOARD
SELECTEDARCHITRAVES
50MM RENDEREDFOAM
10MMPLASTERBOARDWALL LINING TO90MM STUD WALL
SPOTTED GUMTIMBER SCREEN AS
SELECTED.90MM X 32MM.
64MM GAPS.
TIMBER POST ASSELECTED
BARGE CAPPING
RAKED 4.5MMHARDIEFLEX
CEMENT SHEET
RIDGE CAPPING
EXPOSEDAGGREGATE
CONCRETE
1:50 @ A3
ENTRY PASSAGE
Project No:
Drawn:
Date:
Revision:
Scale:
Drawing No:
Drawing:Project:
Torquay, VIC., 3228
SECTION 4 SHT.214-66 15/12/2015
BA - A12 of 20
98 Pakington Street, Geelong West, Vic., 3218
T 5221 8409 F 5229 7433
www.derbyshire.com.au
ABN 80 060 577 648
Revisions:- - -
DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes
CONSTRUCTION
W5D7
R.L. 100.40
R.L. 103.1
R.L. 104.3
MATERIALS & FINISHES SCHEDULE:CA1 CARPETCB COLORBOND SHEET ROOFINGCC COVED CORNICECOS CONCRETE SLABMDF PAINTED MDFMR MOISTURE RESISTANT PLASTERBOARDPB PLASTERBOARD PAINT FINISHSK1 TIMBER SKIRTINGTD TIMBER DECKINGVB1 SOFFIT LINING SHEETING
REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH
ABBREVIATIONS:B BULKHEADBC BARGE FLASHING & CAPPINGCOL STEEL COLUMNDP DOWNPIPEEXH EXHAUST DUCTFCL FINISHED CEILING LEVELFFL FINISHED FLOOR LEVELG SWINGING GATEGAS EXTERNAL GAS OUTLETIHW INSTANTANEOUS HOT WATERMB ELECTRICAL METERBOARDNGL NATURAL GROUND LINEOP OVERFLOW POPPC PARAPET CAPPINGRL RELATIVE LEVELRWT RAINWATER TANKRWH RAINWATER HEADSHR SHOWERSP SPREADER
NOTESN1:THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANYSTRUCTURAL OR CIVIL ENGINEERING COMPUTATIONSAND DRAWINGS; AND ALL OTHER CONSULTANTSDRAWINGS / DETAILS AND WITH ANY OTHER WRITTENINSTRUCTIONS ISSUED IN THE COURSE OF THECONTRACT.N2:GLAZING, INCLUDING SAFETY GLAZING, SHALL BEINSTALLED TO A SIZE, TYPE AND THICKNESS SO AS TOCOMPLY WITH:- BCA PART 3 FOR CLASS 1 AND 10BUILDINGS WITHIN A DESIGN WIND SPEED OF NOT MORETHAN N3; AND - NCC 2014 BCA VOL 1 PART B1.4 FORCLASS 2 AND 9 BUILDINGS.N3:THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHANY HOUSE ENERGY RATING (HERS) REPORT AND SHALLBE CONSTRUCTED IN ACCORDANCE WITH THE STAMPEDPLANS ENDORSED BY THE ACCREDITED THERMALPERFORMANCE ASSESSOR WITHOUT ALTERATIONN4:WHERE REQUIRED TREAT AREA BENEATH FLOOR AGAINSTTERMITE INFESTATION IN ACCORDANCE WITH RELEVANTSTANDARD. CONTACT THE RELEVANT MUNICIPAL COUNCILTO DETERMINE IF THIS IS MANDATORYN5:REFER TO SCHEDULES FOR DIMENSIONED DOOR &WINDOW ELEVATIONS. WINDOW SIZES NOMINATED ARENOMINAL ONLY. ACTUAL SIZES MAY VARY ACCORDING TOMANUFACTURERN6:STEPS TO DECK. 190MM MAX. RISER. 250MM MIN. GOINGTREADSN8:REFER TO STRUCTURAL ENGINEERING DOCUMENTS FORFOOTINGS & SLAB SPECIFICATION, FLOOR & WALLFRAMING.N9:REFER TO ENERGY REPORT FOR NOMINATION OF ALLINSULATION.
SECTION 41:50S/4
COLORBOND ROOFSHEETING, SARKING AND
FLASHING AS REQUIRED TORENDER ROOF WATERTIGHT
INSULATION BATTS TOROOF AS PERSPECIFICATION
PREFABRICATED ROOFTRUSS @ 600MM CENTRESAS PER MANUFACTURERS
SPECIFICATIONS
SLAB & CONCRETEFOOTINGS TO STRUCTURAL
ENGINEERS DETAILSNGL
POWDERCOATALUMINIUM WINDOWS
SELECTEDSKIRTING
FLUSHPLASTERBOARD
10MMPLASTERBOARDWALL LINING TO
90MM STUD WALL
SPOTTED GUMTIMBER SCREEN ASSELECTED.90MM X 32MM.64MM GAPS.
BARGE CAPPING
RAKED 4.5MMHARDIEFLEXCEMENT SHEET
RIDGE CAPPING
COLORBONDCORRUGATED METALSHEET CLADDING
1:50 @ A3
SIT
E B
OU
ND
AR
Y
KITCHENPASSAGE DINING
Project No:
Drawn:
Date:
Revision:
Scale:
Drawing No:
Drawing:Project:
Torquay, VIC., 3228
DOOR SCHEDULE SHT.114-66 15/12/2015
BA - A13 of 20
98 Pakington Street, Geelong West, Vic., 3218
T 5221 8409 F 5229 7433
www.derbyshire.com.au
ABN 80 060 577 648
Revisions:- - -
DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes
CONSTRUCTION
MATERIALS & FINISHES SCHEDULE:MDF PAINTED MDF
REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH
ABBREVIATIONS:CSD CAVITY SLIDING DOORCG CLEAR GLAZINGF FIXED PANELOG OBSCURE GLAZINGSD SLIDING DOOR
NOTESN1:GLAZING, INCLUDING SAFETY GLAZING, SHALL BEINSTALLED TO A SIZE, TYPE AND THICKNESS SO AS TOCOMPLY WITH:- BCA PART 3 FOR CLASS 1 AND 10BUILDINGS WITHIN A DESIGN WIND SPEED OF NOT MORETHAN N3; AND - NCC 2014 BCA VOL 1 PART B1.4 FORCLASS 2 AND 9 BUILDINGS.SAFETY GLASS TO BE USED INTHE FOLLOWING CASES:I) ALL ROOMS – WITHIN 500mm VERTICAL OF THE FLOOR.II) BATHROOMS – WITHIN 2000mm OF THE FLOOR.III) LAUNDRY – WITHIN 1200mm VERTICAL FROM FLOORAND/OR WITHIN 300mm HORIZONTAL FROM ALL DOORS.IV) DOORWAY – WITHIN 300mm HORIZONTAL FROMDOORS.SHOWER SCREENS SHALL BE GRADE A SAFETY GLASS.N2:THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHANY HOUSE ENERGY RATING (HERS) REPORT AND SHALLBE CONSTRUCTED IN ACCORDANCE WITH THE STAMPEDPLANS ENDORSED BY THE ACCREDITED THERMALPERFORMANCE ASSESSOR WITHOUT ALTERATIONN3:DOOR SIZES NOMINATED ARE NOMINAL ONLY. ACTUALSIZES MAY VARY ACCORDING TO MANUFACTURERN4:W.C. DOORS TO TOILET PANS LOCATED WITHIN 1.2m OFTHE DOOR JAMB LIFT OFF HINGES MUST BE FITTED.OTHERWISE THE DOORS MUST SWING OUTWARDS.N5:ALL WINDOWS AND DOORS TO BE SITE MEASURED PRIORTO MANUFACTURER / ORDER.N6:ALL WINDOWS & DOORS TO BE IN ACCORDANCE WITHAS1288-2011N7:PROVIDE DOOR THRSHOLD TO ALL EXTERNAL DOORSN8:ALL DOORS & WINDOWS VIEWED FROM OUTSIDE UNLESSNOTED OTHERWISEN9:PROVIDE LOCKS TO ALL OPENABLE WINDOWS ANDEXTERNAL DOORSN10:ALLOW FOR WEATHER SEALS TO ALL EDGES OF OPENINGWINDOW SASHES AND DOORS.N11:HARDWARE & FURNITURE TO BE PURCHASED BY CLIENT.
ID D1 D2 D3 D4 D5
Location ENTRY LAUNDRY LIVING / DINING GARAGE / ENTRY BED 2
Height 2,650 2,340 2,100 2,340 2,400Width 1,400 820 3,614 1,320 820
Elevation
1,400
2,65
0
820
2,34
0
1,320
2,34
0
820
2,40
0
Orientation SOUTH WEST NORTH N/A N/A
Door Leaf Type SOLID ALUMINIUM & GLAZED ALUMINIUM & GLAZED HOLLOW-CORE HOLLOW-CORE
Frame Type ALUMINIUM ALUMINIUM ALUMINIUM H/DUTY CAVITY DOOR UNIT TIMBER
Frame Finish POWDERCOAT POWDERCOAT POWDERCOAT PAINT PAINT
Hardware AS SELECTED AS SELECTED AS SELECTED AS SELECTED AS SELECTED
Operation Type PIVOT SWINGING 2 SLIDING. 1 FIXED. CAVITY SLIDER SWINGING
Glazing N/A SINGLE GLAZED DOUBLE GLAZED N/A N/A
Extras THIN VERT. SPOTTED GUM. BOTH SIDES - - - -
Comments - WHITE TRANSLUCENT - - -
Door Schedule
ID D6 D7 D8 D9
Location BED 2 ROBE PASSAGE KITCHEN / LAUNDRY BED 3
Height 2,400 2,700 2,350 2,360Width 4,640 1,530 970 2,060
Elevation
4,640
2,40
0
970
2,35
0
2,060
2,36
0
Orientation N/A N/A N/A N/A
Door Leaf Type MDF DOORS PAINTED HOLLOW-CORE HOLLOW-CORE HOLLOW-CORE
Frame Type SLIDING ROBE DOOR UNIT H/DUTY CAVITY DOOR UNIT H/DUTY CAVITY DOOR UNIT H/DUTY CAVITY DOOR UNIT
Frame Finish AS SELECTED PAINT PAINT PAINT
Hardware AS SELECTED AS SELECTED AS SELECTED AS SELECTED
Operation Type SLIDING CAVITY SLIDER CAVITY SLIDER CAVITY SLIDER
Glazing N/A N/A N/A N/A
Extras - - - -
Comments - RECESSED CEILING TRACK - -
Door Schedule
1:50 @ A3
Project No:
Drawn:
Date:
Revision:
Scale:
Drawing No:
Drawing:Project:
Torquay, VIC., 3228
DOOR SCHEDULE SHT.214-66 15/12/2015
BA - A14 of 20
98 Pakington Street, Geelong West, Vic., 3218
T 5221 8409 F 5229 7433
www.derbyshire.com.au
ABN 80 060 577 648
Revisions:- - -
DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes
CONSTRUCTION
MATERIALS & FINISHES SCHEDULE:MDF PAINTED MDF
REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH
ABBREVIATIONS:CSD CAVITY SLIDING DOORCG CLEAR GLAZINGF FIXED PANELOG OBSCURE GLAZINGSD SLIDING DOOR
NOTESN1:GLAZING, INCLUDING SAFETY GLAZING, SHALL BEINSTALLED TO A SIZE, TYPE AND THICKNESS SO AS TOCOMPLY WITH:- BCA PART 3 FOR CLASS 1 AND 10BUILDINGS WITHIN A DESIGN WIND SPEED OF NOT MORETHAN N3; AND - NCC 2014 BCA VOL 1 PART B1.4 FORCLASS 2 AND 9 BUILDINGS.SAFETY GLASS TO BE USED INTHE FOLLOWING CASES:I) ALL ROOMS – WITHIN 500mm VERTICAL OF THE FLOOR.II) BATHROOMS – WITHIN 2000mm OF THE FLOOR.III) LAUNDRY – WITHIN 1200mm VERTICAL FROM FLOORAND/OR WITHIN 300mm HORIZONTAL FROM ALL DOORS.IV) DOORWAY – WITHIN 300mm HORIZONTAL FROMDOORS.SHOWER SCREENS SHALL BE GRADE A SAFETY GLASS.N2:THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHANY HOUSE ENERGY RATING (HERS) REPORT AND SHALLBE CONSTRUCTED IN ACCORDANCE WITH THE STAMPEDPLANS ENDORSED BY THE ACCREDITED THERMALPERFORMANCE ASSESSOR WITHOUT ALTERATIONN3:DOOR SIZES NOMINATED ARE NOMINAL ONLY. ACTUALSIZES MAY VARY ACCORDING TO MANUFACTURERN4:W.C. DOORS TO TOILET PANS LOCATED WITHIN 1.2m OFTHE DOOR JAMB LIFT OFF HINGES MUST BE FITTED.OTHERWISE THE DOORS MUST SWING OUTWARDS.N5:ALL WINDOWS AND DOORS TO BE SITE MEASURED PRIORTO MANUFACTURER / ORDER.N6:ALL WINDOWS & DOORS TO BE IN ACCORDANCE WITHAS1288-2011N7:PROVIDE DOOR THRSHOLD TO ALL EXTERNAL DOORSN8:ALL DOORS & WINDOWS VIEWED FROM OUTSIDE UNLESSNOTED OTHERWISEN9:PROVIDE LOCKS TO ALL OPENABLE WINDOWS ANDEXTERNAL DOORSN10:ALLOW FOR WEATHER SEALS TO ALL EDGES OF OPENINGWINDOW SASHES AND DOORS.N11:HARDWARE & FURNITURE TO BE PURCHASED BY CLIENT.
ID D10 D11 D12 D13 D13A D14
Location BED 3 BED 3 ROBE BATHROOM MASTER BED MASTER BED WIR MASTER BED ENSUITE
Height 2,360 2,400 2,400 2,400 2,400 2,400Width 1,860 1,710 820 820 2,100 820
Elevation
2,36
0
1,860 1,710
2,40
0
820
2,40
0
820
2,40
0
2,100
2,40
0
820
2,40
0
Orientation N/A N/A N/A N/A N/A N/A
Door Leaf Type HOLLOW-CORE MDF DOORS PAINTED HOLLOW-CORE HOLLOW-CORE MIRROR DOORS HOLLOW-CORE
Frame Type H/DUTY CAVITY DOOR UNIT SLIDING ROBE DOOR UNIT TIMBER TIMBER SLIDING ROBE DOOR UNIT SLIDING ROBE DOOR UNIT
Frame Finish PAINT AS SELECTED PAINT PAINT AS SELECTED PAINT
Hardware AS SELECTED AS SELECTED AS SELECTED AS SELECTED AS SELECTED AS SELECTED
Operation Type CAVITY SLIDER SLIDING SWINGING SWINGING SLIDING CAVITY SLIDER
Glazing N/A N/A N/A N/A N/A N/A
Extras - - - - - -
Comments - - - - - -
Door Schedule
ID RD1 RD2
Location GARAGE GARAGE REAR
Height 2,400 2,400Width 5,400 1,200
Elevation
2,40
0
5,400
5,380
2,40
0
Orientation SOUTH NORTH
Door Leaf Type SECTIONAL LIFT DOOR. COLORBOND ROLLER DOOR. COLORBOND
Frame Type STEEL STEEL
Frame Finish GALVANISED / COLORBOND GALVANISED / COLORBOND
Hardware AS SELECTED AS SELECTED
Operation Type SECTIONAL LIFT ROLLER
Glazing N/A N/A
Extras - -
Comments - -
Door Schedule
1:50 @ A3
Project No:
Drawn:
Date:
Revision:
Scale:
Drawing No:
Drawing:Project:
Torquay, VIC., 3228
WINDOW SCHEDULE SHT.1
14-66 15/12/2015
BA - A15 of 20
98 Pakington Street, Geelong West, Vic., 3218
T 5221 8409 F 5229 7433
www.derbyshire.com.au
ABN 80 060 577 648
Revisions:- - -
DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes
CONSTRUCTION
ABBREVIATIONS:CG CLEAR GLAZINGF FIXED PANELOG OBSCURE GLAZING
NOTESN1:GLAZING, INCLUDING SAFETY GLAZING, SHALL BEINSTALLED TO A SIZE, TYPE AND THICKNESS SO AS TOCOMPLY WITH:- BCA PART 3 FOR CLASS 1 AND 10BUILDINGS WITHIN A DESIGN WIND SPEED OF NOT MORETHAN N3; AND - NCC 2014 BCA VOL 1 PART B1.4 FORCLASS 2 AND 9 BUILDINGS.SAFETY GLASS TO BE USED INTHE FOLLOWING CASES:I) ALL ROOMS – WITHIN 500mm VERTICAL OF THE FLOOR.II) BATHROOMS – WITHIN 2000mm OF THE FLOOR.III) LAUNDRY – WITHIN 1200mm VERTICAL FROM FLOORAND/OR WITHIN 300mm HORIZONTAL FROM ALL DOORS.IV) DOORWAY – WITHIN 300mm HORIZONTAL FROMDOORS.N2:THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHANY HOUSE ENERGY RATING (HERS) REPORT AND SHALLBE CONSTRUCTED IN ACCORDANCE WITH THE STAMPEDPLANS ENDORSED BY THE ACCREDITED THERMALPERFORMANCE ASSESSOR WITHOUT ALTERATIONN3:DOOR SIZES NOMINATED ARE NOMINAL ONLY. ACTUALSIZES MAY VARY ACCORDING TO MANUFACTURERN4:ALL WINDOWS AND DOORS TO BE SITE MEASURED PRIORTO MANUFACTURER / ORDER.N5:ALL WINDOWS & DOORS TO BE IN ACCORDANCE WITHAS1288-2011N6:PROVIDE DOOR THRSHOLD TO ALL EXTERNAL DOORSN7:ALL DOORS & WINDOWS VIEWED FROM OUTSIDE UNLESSNOTED OTHERWISEN8:PROVIDE LOCKS TO ALL OPENABLE WINDOWS ANDEXTERNAL DOORSN9:ALLOW FOR WEATHER SEALS TO ALL EDGES OF OPENINGWINDOW SASHES AND DOORS.
ID W1 W2 W2A W3 W4Location MASTER BED ENSUITE MASTER BED ENSUITE MASTER BED ENSUITE ENTRY (OVER DOOR) BED 2Height 600 600 600 1,564 2,098Width 1,800 1,800 600 1,500 1,722Window sill height 1,050 1,050 1,050 2,700 0Window head height 1,650 1,650 1,650 4,264 2,098
2D Symbol1,800 1,800 600 1,500 1,722
Elevation
1,800
600
600
1,791
600
591
1,500
1,56
4
1,722
2,09
8
Orientation SOUTH SOUTH WEST SOUTH WESTAccessoriesFinish POWDERCOAT POWDERCOAT POWDERCOAT POWDERCOAT POWDERCOATFrame Type ALUMINIUM ALUMINIUM ALUMINIUM ALUMINIUM ALUMINIUMGlazing DBL. GLAZED SINGLE GLAZED SINGLE GLAZE DBL. GLAZED DBL. GLAZEDOperation Type SLIDING FIXED FIXED FIXED SLIDINGVision Panel Type WHITE TRANSLUCENT COLOURBACK GLASS. MONUMENT TINTED MONUMENT TINTED CLEAR CLEARManufacturerComments MITRED BUTT JOINT CORNER TO W2A
Window List
ID W5 W6 W7 W7A W8Location KITCHEN DINING LIVING LIVING ROOM LIVING ROOMHeight 600 2,098 600 600 600Width 1,856 899 1,800 1,800 1,856Window sill height 900 0 900 900 900Window head height 1,500 2,098 1,500 1,500 1,500
2D Symbol1,856 899 1,800 1,800 1,856
Elevation
1,856
600
899
2,09
8
600
1,800
600
1,800 1,856
600
Orientation WEST NORTH NORTH EAST EASTAccessoriesFinish POWDERCOAT POWDERCOAT POWDERCOAT POWDERCOAT POWDERCOATFrame Type ALUMINIUM ALUMINIUM ALUMINIUM ALUMINIUM ALUMINIUMGlazing DBL. GLAZED DBL. GLAZED SINGLE GLAZED SINGLE GLAZED DBL. GLAZEDOperation Type FIXED DBL. HUNG FIXED FIXED SLIDINGVision Panel Type CLEAR CLEAR CLEAR CLEAR CLEARManufacturerComments BUTT GLAZED CORNER BUTT GLAZED CORNER
Window List
1:50 @ A3
A
Revisions:A W1 WIDTH REVISED 02.11.15
W2/2A COLOUR REVISED
Project No:
Drawn:
Date:
Revision:
Scale:
Drawing No:
Drawing:Project:
Torquay, VIC., 3228
WINDOW SCHEDULE SHT.2
14-66 15/12/2015
BA - A16 of 20
98 Pakington Street, Geelong West, Vic., 3218
T 5221 8409 F 5229 7433
www.derbyshire.com.au
ABN 80 060 577 648
Revisions:- - -
DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes
CONSTRUCTION
ABBREVIATIONS:CG CLEAR GLAZINGF FIXED PANELOG OBSCURE GLAZING
NOTESN1:GLAZING, INCLUDING SAFETY GLAZING, SHALL BEINSTALLED TO A SIZE, TYPE AND THICKNESS SO AS TOCOMPLY WITH:- BCA PART 3 FOR CLASS 1 AND 10BUILDINGS WITHIN A DESIGN WIND SPEED OF NOT MORETHAN N3; AND - NCC 2014 BCA VOL 1 PART B1.4 FORCLASS 2 AND 9 BUILDINGS.SAFETY GLASS TO BE USED INTHE FOLLOWING CASES:I) ALL ROOMS – WITHIN 500mm VERTICAL OF THE FLOOR.II) BATHROOMS – WITHIN 2000mm OF THE FLOOR.III) LAUNDRY – WITHIN 1200mm VERTICAL FROM FLOORAND/OR WITHIN 300mm HORIZONTAL FROM ALL DOORS.IV) DOORWAY – WITHIN 300mm HORIZONTAL FROMDOORS.N2:THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHANY HOUSE ENERGY RATING (HERS) REPORT AND SHALLBE CONSTRUCTED IN ACCORDANCE WITH THE STAMPEDPLANS ENDORSED BY THE ACCREDITED THERMALPERFORMANCE ASSESSOR WITHOUT ALTERATIONN3:DOOR SIZES NOMINATED ARE NOMINAL ONLY. ACTUALSIZES MAY VARY ACCORDING TO MANUFACTURERN4:ALL WINDOWS AND DOORS TO BE SITE MEASURED PRIORTO MANUFACTURER / ORDER.N5:ALL WINDOWS & DOORS TO BE IN ACCORDANCE WITHAS1288-2011N6:PROVIDE DOOR THRSHOLD TO ALL EXTERNAL DOORSN7:ALL DOORS & WINDOWS VIEWED FROM OUTSIDE UNLESSNOTED OTHERWISEN8:PROVIDE LOCKS TO ALL OPENABLE WINDOWS ANDEXTERNAL DOORSN9:ALLOW FOR WEATHER SEALS TO ALL EDGES OF OPENINGWINDOW SASHES AND DOORS.
ID W9 W10 W11 W12 W13Location BED 3 BATHROOM MASTER BED WIR MASTER BED ENSUITEHeight 600 2,098 2,098 2,098 600Width 1,856 899 1,722 899 1,200Window sill height 900 0 0 0 1,700Window head height 1,500 2,098 2,098 2,098 2,300
2D Symbol1,856 899 1,722 899
1,200
Elevation
1,856
600
899
2,09
8
1,722
2,09
8
899
2,09
8
1,200
600
Orientation EAST EAST EAST EAST EASTAccessoriesFinish POWDERCOAT POWDERCOAT POWDERCOAT POWDERCOAT POWDERCOATFrame Type ALUMINIUM ALUMINIUM ALUMINIUM ALUMINIUM ALUMINIUMGlazing DBL. GLAZED SINGLE GLAZED DBL. GLAZED DBL. GLAZED DBL. GLAZEDOperation Type SLIDING DBL. HUNG SLIDING FIXED SLIDINGVision Panel Type CLEAR WHITE TRANSLUCENT CLEAR WHITE TRANSLUCENT WHITE TRANSLUCENTManufacturerComments
Window List
1:50 @ A3
Project No:
Drawn:
Date:
Revision:
Scale:
Drawing No:
Drawing:Project:
Torquay, VIC., 3228
PLAN DET. & INT. ELEV -MASTER BED ENS. & WIR
14-66 15/12/2015
BA - A17 of 20
98 Pakington Street, Geelong West, Vic., 3218
T 5221 8409 F 5229 7433
www.derbyshire.com.au
ABN 80 060 577 648
Revisions:- - -
DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes
CONSTRUCTION
IE 01
IE 02
IE 03
IE 04
IE 05
IE 06
IE 07
IE 08
900
1,20
0
2,10
060
0
300
560
401,
500
300
2,70
0
D14
900
1,75
050
045
0
2,10
060
0
2,70
0
300
560
40
900
150
600
1,05
0
2,70
0
W1
300
560
40
900
150
1,35
030
0
2,70
0
909101,72090
902,63090
9091080092099
902,63099
2,729 90
901,820
902,350
901,894
1,800566
90
904,260
90
902,350
901,210
61090
610 900 610 90
2,120 90
904,260
90
610 900 610 90
MATERIALS:CA1 CARPETCOS CONCRETE SLABFSS FRAMELESS SHOWER SCREENGMD GLOSS MELAMINE DOORSGS GLASS SPLASHBACKKI1 KICKER TYPE 1LA1 LAMINATE TYPE 1LB1 LAMINATED BENCHTOPMA1 WHITE MELAMINEMDF PAINTED MDFMS1 MIRROR SPLASHBACKPB PLASTERBOARD PAINT FINISHPB2 WET AREA PLASTERBOARD - VILLABOARDRS1 RECONSTITUTED STONESK TIMBER SKIRTINGTF TIMBER FLOORINGTL1 FLOOR TILETL2 WALL TILETSP TILE SPLASHBACK.TSK TILE SKIRTINGVW1 VINYL WRAP
REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH
ABBREVIATIONS:AS ADJUSTABLE SHELFBS BATH SPOUTCSD CAVITY SLIDING DOORCTB COUNTER TOP BASINDRW DRAWERDRY DRYERDW DISHWASHERFCL FINISHED CEILING LEVELFFL FINISHED FLOOR LEVELFS FIXED SHELFFW FLOOR WASTEGFS GLAZED FIXED SHELFGPO GENERAL PURPOSE OUTLETHR HANGING RAILHTR HAND TOWEL RAILLTR LAUNDRY TROUGHMH MANHOLEMI MIRRORMX MIXER TAPMW MICROWAVENOM NOMINAL LENGTHNS NOOK SHELFOS OPEN SHELFPL PENDANT LIGHTRA RETURN AIR DUCTREF REFRIGERATORS(U) SINK UNDERMOUNTSHR SHOWERSHH SHOWER HEADTR TOWEL RAIL (TR(H) - heated)TRH TOILET ROLL HOLDERTS TOILET SUITEWB WALL HUNG BASINWO WALL OVENWM WASHING MACHINE
NOTESN1:THE LOCATION OF SERVICES IS APPROXIMATE ONLY.BUILDER TO DETERMINE THE EXACT LOCATIONS OFSERVICES ON SITE PRIOR TO TENDERING.N2:DRAWINGS ARE TO BE READ IN CONJUNCTION WIITHJOINERY SCHEDULE IN SPECIFICATIONN3:CHECK & CONFIRM ALL DIMENSIONS ON SITE PRIOR TOMANUFACTURING / CONSTRUCTIONN4:UNLESS OTHERWISE NOTED, ALL INTERNAL CARCASSESTO BE WHITE MELAMINEN5:ALL WET AREAS TO COMPLY WITH AS 3740. WALL FINISHESSHALL BE IMPERVIOUS TO A HEIGHT OF 1800mm ABOVEFLOOR LEVEL TO SHOWER ENCLOSURES AND 300mmABOVE BATHS, BASINS, SINKS AND TROUGHS IF WITHIN75mm OF THE WALL. REFER TO CODE FOR ALLREQUIREMENTS.N6:W.C. DOORS TO TOILET PANS LOCATED WITHIN 1.2m OFTHE DOOR JAMB LIFT OFF HINGES MUST BE FITTED.OTHERWISE THE DOORS MUST SWING OUTWARDS.N7:SAFETY GLASS TO BE USED IN THE FOLLOWING CASES:I) ALL ROOMS – WITHIN 500mm VERTICAL OF THE FLOOR.II) BATHROOMS – WITHIN 2000mm OF THE FLOOR.III) LAUNDRY – WITHIN 1200mm VERTICAL FROM FLOORAND/OR WITHIN 300mm HORIZONTAL FROM ALL DOORS.IV) DOORWAY – WITHIN 300mm HORIZONTAL FROMDOORS.SHOWER SCREENS SHALL BE GRADE A SAFETY GLASS.
J0 JOINERY NO.
XX MATERIAL
W0 WINDOW NO.
D0 DOOR NO.
300
300
300
300
300
300
300
300
300
2,70
0
800
800
250
1,35
020
030
060
0
800
800
200
300
600
800
800
200
300
600
250
1,35
0
800
800
200
300
600
300
300
300
300
300
300
300
300
2,40
030
0
2,70
0
D14
900
1,50
0
2,40
0
300
300
300
300
300
300
300
300
D13A
PLAN DETAIL - ENS & WIR1:50
INT. ELEV. 01 - ENS1:50IE 01 INT. ELEV. 02 - ENS
1:50IE 02
INT. ELEV. 03 - ENS1:50IE 03 INT. ELEV. 04 - ENS
1:50IE 04
INT. ELEV. 05 - WIR1:50IE 05 INT. ELEV. 06 - WIR
1:50IE 06 INT. ELEV. 07 - WIR1:50IE 07 INT. ELEV. 08 - WIR
1:50IE 08
CAROMA CUBE1800MM BATH
TL1 TL1
TL1 TL1
CA1 CA1 CA1 CA1
TL2
TL2
TL2
TL2
PB2
PB2
PB2
W1
W2
W2A
W13 W12
D13A
D14
SEMI-FRAMELESSSHOWER SCREEN
FULL HEIGHT TILESTO THIS WALL ALSO
1:50 @ A3
TS
FS
FS FS
FS
FS
FSDRW
DRW
DRW
DRW
BN
MX
MI
TS
HR
HR
HR
HR
HR
HR
HR
HR
HRHR
FS
FS
DRW DRW
DRW DRW
DRW DRW
FS
FS
FS
FS
FS
FS
FS
FS
FS
FS
FS
FS
FS
FS
FS
FS
DRW
DRW
DRW
FS FS
FS
FSFSFS FS
FS
FS
FS
FS
FS
DRW
DRW
DRW
FRAMELESS
SHH
SHR
MX
SHH
SHR
MX
ENS.TILES
W.I.R.CARPET
FS FS
NS
FW
NS
TSBATH
TR TR
TRH
DRW DRW DRW DRW
FS FSFSFSFS
TRH
BATH
TR TR
TR
FS FS
BS MX
HTR
HTR
BS
(W2 BEHIND PLASTER)
(W2ABEHIND
PLASTER)
A
Revisions:A W1 WIDTH REVISED
W2 & W2A HIDDEN INTERNALLY 02.11.1502/11/2015
LA1
LA1
RS1
RS1
RS1
TSP
LA1
TSP
TSP
Project No:
Drawn:
Date:
Revision:
Scale:
Drawing No:
Drawing:Project:
Torquay, VIC., 3228
PLAN DET. & INT. ELEV. -BATH & BED 3
14-66 15/12/2015
BA - A18 of 20
98 Pakington Street, Geelong West, Vic., 3218
T 5221 8409 F 5229 7433
www.derbyshire.com.au
ABN 80 060 577 648
Revisions:- - -
DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes
CONSTRUCTION
MATERIALS:CA1 CARPETCOS CONCRETE SLABFSS FRAMELESS SHOWER SCREENGMD GLOSS MELAMINE DOORSGS GLASS SPLASHBACKKI1 KICKER TYPE 1LA1 LAMINATE TYPE 1LB1 LAMINATED BENCHTOPMA1 WHITE MELAMINEMDF PAINTED MDFMS1 MIRROR SPLASHBACKPB PLASTERBOARD PAINT FINISHPB2 WET AREA PLASTERBOARD - VILLABOARDRS1 RECONSTITUTED STONESK TIMBER SKIRTINGTF TIMBER FLOORINGTL1 FLOOR TILETL2 WALL TILETSP TILE SPLASHBACK.TSK TILE SKIRTINGVW1 VINYL WRAP
REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH
ABBREVIATIONS:AS ADJUSTABLE SHELFBS BATH SPOUTCSD CAVITY SLIDING DOORCTB COUNTER TOP BASINDRW DRAWERDRY DRYERDW DISHWASHERFCL FINISHED CEILING LEVELFFL FINISHED FLOOR LEVELFS FIXED SHELFFW FLOOR WASTEGFS GLAZED FIXED SHELFGPO GENERAL PURPOSE OUTLETHR HANGING RAILHTR HAND TOWEL RAILLTR LAUNDRY TROUGHMH MANHOLEMI MIRRORMX MIXER TAPMW MICROWAVENOM NOMINAL LENGTHNS NOOK SHELFOS OPEN SHELFPL PENDANT LIGHTRA RETURN AIR DUCTREF REFRIGERATORS(U) SINK UNDERMOUNTSHR SHOWERSHH SHOWER HEADTR TOWEL RAIL (TR(H) - heated)TRH TOILET ROLL HOLDERTS TOILET SUITEWB WALL HUNG BASINWO WALL OVENWM WASHING MACHINE
NOTESN1:THE LOCATION OF SERVICES IS APPROXIMATE ONLY.BUILDER TO DETERMINE THE EXACT LOCATIONS OFSERVICES ON SITE PRIOR TO TENDERING.N2:DRAWINGS ARE TO BE READ IN CONJUNCTION WIITHJOINERY SCHEDULE IN SPECIFICATIONN3:CHECK & CONFIRM ALL DIMENSIONS ON SITE PRIOR TOMANUFACTURING / CONSTRUCTIONN4:UNLESS OTHERWISE NOTED, ALL INTERNAL CARCASSESTO BE WHITE MELAMINEN5:ALL WET AREAS TO COMPLY WITH AS 3740. WALL FINISHESSHALL BE IMPERVIOUS TO A HEIGHT OF 1800mm ABOVEFLOOR LEVEL TO SHOWER ENCLOSURES AND 300mmABOVE BATHS, BASINS, SINKS AND TROUGHS IF WITHIN75mm OF THE WALL. REFER TO CODE FOR ALLREQUIREMENTS.N6:W.C. DOORS TO TOILET PANS LOCATED WITHIN 1.2m OFTHE DOOR JAMB LIFT OFF HINGES MUST BE FITTED.OTHERWISE THE DOORS MUST SWING OUTWARDS.N7:SAFETY GLASS TO BE USED IN THE FOLLOWING CASES:I) ALL ROOMS – WITHIN 500mm VERTICAL OF THE FLOOR.II) BATHROOMS – WITHIN 2000mm OF THE FLOOR.III) LAUNDRY – WITHIN 1200mm VERTICAL FROM FLOORAND/OR WITHIN 300mm HORIZONTAL FROM ALL DOORS.IV) DOORWAY – WITHIN 300mm HORIZONTAL FROMDOORS.SHOWER SCREENS SHALL BE GRADE A SAFETY GLASS.
J0 JOINERY NO.
XX MATERIAL
W0 WINDOW NO.
D0 DOOR NO.
IE 10
IE 09
IE 13
IE 14IE 11
IE 12
90 1,100 10 910 90
90 2,020 90 3,590 30
901,810
93010
1,510
904,260
90
1201,770901,730906201,40090
1203,590902,02090
903,690
90450
120
903,690
540120
900
2,70
0
900
900
300
2,70
0
W10
300
560
40
900
300
1,00
050
0
2,70
0
900
900
300
600
2,10
060
0
1,20
030
01,
200
300
300
300
300
300
300
300
300
300
2,70
0
1,70
010
020
010
0
D11
2,40
030
0
2,70
0
300
300
300
300
300
300
300
300
90
900
90
900
300
560
40
900
300
1,00
050
0
D12
PLAN DETAIL - BATH & BED 31:50
INT. ELEV. 10 - BATH1:50IE 10INT. ELEV. 09 - BATH
1:50IE 09
INT. ELEV. 13 -BED 31:50IE 13 INT. ELEV. 14 - BED 3
1:50IE 14
INT. ELEV. 11 - BATH1:50IE 11
INT. ELEV. 12 - BATH1:50IE 12
TL2
TL1
RS1
TL1TSK
PB2
TL1
PB2
CA1
PB
CA1
PB
MDF
LA1
RS1
W10
D12
D11
D10
D9
W9
TL2
SEMI-FRAMELESSSHOWER SCREEN
1:50 @ A3
SHH
TS
BNMX
MI
SHR
MX
SHH
SHR
MX
FRAMELESS
TRH
MX
BN
TR TR
TRH
NS
HR
FS
FS
FS
FS
FS
DRW
DRW
DRW
BATHTILES CARPET
BED 3
FWNS
TS
TR
TRH
BN.
TR
MX
HR
Project No:
Drawn:
Date:
Revision:
Scale:
Drawing No:
Drawing:Project:
Torquay, VIC., 3228
PLAN DET. & INT. ELEV. -BED 2, LAUNDRY, PANTRY& KITCHEN
14-66 15/12/2015
BA - A19 of 20
98 Pakington Street, Geelong West, Vic., 3218
T 5221 8409 F 5229 7433
www.derbyshire.com.au
ABN 80 060 577 648
Revisions:- - -
DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes
CONSTRUCTION
MATERIALS:CA1 CARPETCOS CONCRETE SLABFSS FRAMELESS SHOWER SCREENGMD GLOSS MELAMINE DOORSGS GLASS SPLASHBACKKI1 KICKER TYPE 1LA1 LAMINATE TYPE 1LB1 LAMINATED BENCHTOPMA1 WHITE MELAMINEMDF PAINTED MDFMS1 MIRROR SPLASHBACKPB PLASTERBOARD PAINT FINISHPB2 WET AREA PLASTERBOARD - VILLABOARDRS1 RECONSTITUTED STONESK TIMBER SKIRTINGTF TIMBER FLOORINGTL1 FLOOR TILETL2 WALL TILETSP TILE SPLASHBACK.TSK TILE SKIRTINGVW1 VINYL WRAP
REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH
ABBREVIATIONS:AS ADJUSTABLE SHELFBS BATH SPOUTCSD CAVITY SLIDING DOORCTB COUNTER TOP BASINDRW DRAWERDRY DRYERDW DISHWASHERFCL FINISHED CEILING LEVELFFL FINISHED FLOOR LEVELFS FIXED SHELFFW FLOOR WASTEGFS GLAZED FIXED SHELFGPO GENERAL PURPOSE OUTLETHR HANGING RAILHTR HAND TOWEL RAILLTR LAUNDRY TROUGHMH MANHOLEMI MIRRORMX MIXER TAPMW MICROWAVENOM NOMINAL LENGTHNS NOOK SHELFOS OPEN SHELFPL PENDANT LIGHTRA RETURN AIR DUCTREF REFRIGERATORS(U) SINK UNDERMOUNTSHR SHOWERSHH SHOWER HEADTR TOWEL RAIL (TR(H) - heated)TRH TOILET ROLL HOLDERTS TOILET SUITEWB WALL HUNG BASINWO WALL OVENWM WASHING MACHINE
NOTESN1:THE LOCATION OF SERVICES IS APPROXIMATE ONLY.BUILDER TO DETERMINE THE EXACT LOCATIONS OFSERVICES ON SITE PRIOR TO TENDERING.N2:DRAWINGS ARE TO BE READ IN CONJUNCTION WIITHJOINERY SCHEDULE IN SPECIFICATIONN3:CHECK & CONFIRM ALL DIMENSIONS ON SITE PRIOR TOMANUFACTURING / CONSTRUCTIONN4:UNLESS OTHERWISE NOTED, ALL INTERNAL CARCASSESTO BE WHITE MELAMINEN5:ALL WET AREAS TO COMPLY WITH AS 3740. WALL FINISHESSHALL BE IMPERVIOUS TO A HEIGHT OF 1800mm ABOVEFLOOR LEVEL TO SHOWER ENCLOSURES AND 300mmABOVE BATHS, BASINS, SINKS AND TROUGHS IF WITHIN75mm OF THE WALL. REFER TO CODE FOR ALLREQUIREMENTS.N6:W.C. DOORS TO TOILET PANS LOCATED WITHIN 1.2m OFTHE DOOR JAMB LIFT OFF HINGES MUST BE FITTED.OTHERWISE THE DOORS MUST SWING OUTWARDS.N7:SAFETY GLASS TO BE USED IN THE FOLLOWING CASES:I) ALL ROOMS – WITHIN 500mm VERTICAL OF THE FLOOR.II) BATHROOMS – WITHIN 2000mm OF THE FLOOR.III) LAUNDRY – WITHIN 1200mm VERTICAL FROM FLOORAND/OR WITHIN 300mm HORIZONTAL FROM ALL DOORS.IV) DOORWAY – WITHIN 300mm HORIZONTAL FROMDOORS.SHOWER SCREENS SHALL BE GRADE A SAFETY GLASS.
J0 JOINERY NO.
XX MATERIAL
W0 WINDOW NO.
D0 DOOR NO.
D
F
W
DW
IE 15
IE 18
IE 17
IE 19
IE 23
IE 24
IE 21
IE 25
IE 16
IE 22
IE 20
90 3,620 90 1,800 90 610 2,100
90 720 2,900 90 610 1,190 90 610 1,200 900
4,65090
9001,810901,200600902,900710100
2,710901,800903,610100
2,9401,200
61090
904,650
90
902,750
901,810
90
1,05
090
015
030
0
2,40
030
0
300
300
300
300
300
300
300
1,95
015
030
030
0
2,70
0
900
600
900
300
2,70
0
9077
040
900
600
900
300
2,70
0
2,40
030
0
2,70
0
D2
1,05
090
015
0
2,10
030
0
2,40
0
W4
PLAN DETAIL - BED 2, PANTRY, LAUNDRY & KITCHEN1:50
INT. ELEV. 15 - BED 21:50IE 15
INT. ELEV. 18 - L'DRY1:50IE 18INT. ELEV. 17 - L'DRY
1:50IE 17 INT. ELEV. 19 - L'DRY1:50IE 19
INT. ELEV. 16 - BED 21:50IE 16
CA1
CA1
TL1
TSP
TL1
LB1
TL1
LA1 LA1
LA1 LA1
LA1
LB1
TSP
PB
MDF MDFMDFMDF
PB
TSK
1:50 @ A3
FS
FS
FS
FS FS
FS
FS
FS
FS
FS
FS
FS
FS
FS
FS
FS
TR MX
WMDRY
FS FS FS FS
FS
FS
FS
DRW
DRW
DRW
DRW
HR HR HR
HR HR
HR
HR
FS
FS
FS
FS
FS
FS
L'DRYTILESCARPET
BED 2 KITCHENTILES
Project No:
Drawn:
Date:
Revision:
Scale:
Drawing No:
Drawing:Project:
Torquay, VIC., 3228
PLAN DET. & INT. ELEV. -KITCHEN
14-66 15/12/2015
BA - A20 of 20
98 Pakington Street, Geelong West, Vic., 3218
T 5221 8409 F 5229 7433
www.derbyshire.com.au
ABN 80 060 577 648
Revisions:- - -
DO NOT SCALE DRAWING - REFER ONLY TO WRITTEN DIMENSIONSContractor must verify all dimensions and levels on site prior to thecommencement of any works, ordering & or manufacture of any materials.Notify Derbyshire Homes of any discrepancies. Drawings to be read inconjunction with specifications.This drawing is protected by copyright. © 2011 Derbyshire Homes
CONSTRUCTION
9077
040
D8
W5
9077
040
900
600
900
300
900
900
600
2,40
0
D8
9077
040
900
600
1,80
060
030
0
2,70
0
W5
9077
040
900
9077
040
900
600
900
300
2,70
0
9077
040
900
9077
040
900
600
900
300
2,70
0
MATERIALS:CA1 CARPETCOS CONCRETE SLABFSS FRAMELESS SHOWER SCREENGMD GLOSS MELAMINE DOORSGS GLASS SPLASHBACKKI1 KICKER TYPE 1LA1 LAMINATE TYPE 1LB1 LAMINATED BENCHTOPMA1 WHITE MELAMINEMDF PAINTED MDFMS1 MIRROR SPLASHBACKPB PLASTERBOARD PAINT FINISHPB2 WET AREA PLASTERBOARD - VILLABOARDRS1 RECONSTITUTED STONESK TIMBER SKIRTINGTF TIMBER FLOORINGTL1 FLOOR TILETL2 WALL TILETSP TILE SPLASHBACK.TSK TILE SKIRTINGVW1 VINYL WRAP
REFER TO DERBYSHIRE SPECIFICATION FOR COMPLETESPECIFICATION OF MATERIALS & DETAILS OF FINISH
ABBREVIATIONS:AS ADJUSTABLE SHELFBS BATH SPOUTCSD CAVITY SLIDING DOORCTB COUNTER TOP BASINDRW DRAWERDRY DRYERDW DISHWASHERFCL FINISHED CEILING LEVELFFL FINISHED FLOOR LEVELFS FIXED SHELFFW FLOOR WASTEGFS GLAZED FIXED SHELFGPO GENERAL PURPOSE OUTLETHR HANGING RAILHTR HAND TOWEL RAILLTR LAUNDRY TROUGHMH MANHOLEMI MIRRORMX MIXER TAPMW MICROWAVENOM NOMINAL LENGTHNS NOOK SHELFOS OPEN SHELFPL PENDANT LIGHTRA RETURN AIR DUCTREF REFRIGERATORS(U) SINK UNDERMOUNTSHR SHOWERSHH SHOWER HEADTR TOWEL RAIL (TR(H) - heated)TRH TOILET ROLL HOLDERTS TOILET SUITEWB WALL HUNG BASINWO WALL OVENWM WASHING MACHINE
NOTESN1:THE LOCATION OF SERVICES IS APPROXIMATE ONLY.BUILDER TO DETERMINE THE EXACT LOCATIONS OFSERVICES ON SITE PRIOR TO TENDERING.N2:DRAWINGS ARE TO BE READ IN CONJUNCTION WIITHJOINERY SCHEDULE IN SPECIFICATIONN3:CHECK & CONFIRM ALL DIMENSIONS ON SITE PRIOR TOMANUFACTURING / CONSTRUCTIONN4:UNLESS OTHERWISE NOTED, ALL INTERNAL CARCASSESTO BE WHITE MELAMINEN5:ALL WET AREAS TO COMPLY WITH AS 3740. WALL FINISHESSHALL BE IMPERVIOUS TO A HEIGHT OF 1800mm ABOVEFLOOR LEVEL TO SHOWER ENCLOSURES AND 300mmABOVE BATHS, BASINS, SINKS AND TROUGHS IF WITHIN75mm OF THE WALL. REFER TO CODE FOR ALLREQUIREMENTS.N6:W.C. DOORS TO TOILET PANS LOCATED WITHIN 1.2m OFTHE DOOR JAMB LIFT OFF HINGES MUST BE FITTED.OTHERWISE THE DOORS MUST SWING OUTWARDS.N7:SAFETY GLASS TO BE USED IN THE FOLLOWING CASES:I) ALL ROOMS – WITHIN 500mm VERTICAL OF THE FLOOR.II) BATHROOMS – WITHIN 2000mm OF THE FLOOR.III) LAUNDRY – WITHIN 1200mm VERTICAL FROM FLOORAND/OR WITHIN 300mm HORIZONTAL FROM ALL DOORS.IV) DOORWAY – WITHIN 300mm HORIZONTAL FROMDOORS.SHOWER SCREENS SHALL BE GRADE A SAFETY GLASS.
J0 JOINERY NO.
XX MATERIAL
W0 WINDOW NO.
D0 DOOR NO.
9077
040
900
900
9077
040
900
INT. ELEV. 23 - KITCHEN1:50IE 23
INT. ELEV. 24 - KITCHEN1:50IE 24
INT. ELEV. 21 - KITCHEN1:50IE 21
INT. ELEV. 25 - KITCHEN1:50IE 25
INT. ELEV. 20 - KITCHEN1:50IE 20
INT. ELEV. 22 - KITCHEN1:50IE 22
RS1
RS1 RS1
RS1
RS1
RS1 RS1
TL1TL1
TL1 TL1
TL1TL1
PB
PB
GS
RS1
DRW
DRW
DRW
DRW
DRW
DRW
DRW
DRW
DRW
DRW
DRW
DRW
DRW
DRW
DRW
DRW
DRW
DRW
FS
FS
FS
FS
DRW
DRW
DRW
FS
FS
S(U)MX
DW
FS
FS
MXBN
MX BN
REF
FS
DRW
DRW
DRW
FS
COOKTOP
OVENFS
FS
RANGEHOOD
FS