38
KS600/900/1000 Architectural Wall & Facade Systems Construction Details 489 Vertical Panel Joint 489 Fastener Locations 489 Eaves 490 Verge 494 Curved Eaves 497 Corner 498 Drip 503 Lean-to-Roof 504 Abutments to Brickwork 505 Vertical to Horizontal Break 506 Expansion Joint 507 Panel Soffit 508 Soffit 509 Cover Strip for Site Cut Panels 509 Porthole Windows 510 Windows 512 Personnel Doors 514 Up and Over Doors 516 Fixed Wall Louvre 518 Wall Extractor 520 Panel Bearer 521 Pre-Formed Units 522 487 Vertically Laid Insulated Wall & Facade Systems Architectural For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

KS

60

0/9

00/

100

0A

rchi

tect

ural

Wal

l &Fa

cade

Syst

ems

Construction Details 489

• Vertical Panel Joint 489• Fastener Locations 489• Eaves 490• Verge 494• Curved Eaves 497• Corner 498• Drip 503• Lean-to-Roof 504• Abutments to Brickwork 505• Vertical to Horizontal Break 506• Expansion Joint 507• Panel Soffit 508• Soffit 509• Cover Strip for Site Cut Panels 509• Porthole Windows 510• Windows 512• Personnel Doors 514• Up and Over Doors 516• Fixed Wall Louvre 518• Wall Extractor 520• Panel Bearer 521• Pre-Formed Units 522

487

Vertically Laid Insulated Wall & Facade Systems

Architectural

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 2: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

Wall & facade systems can be constructed ‘vertically’ allowing

designers a wider range of layout, visual effects and solutions

488

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 3: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

489

KS6

00/

900/

100

0

AW

P V

erti

cally

Lai

dCo

nstr

ucti

on D

etai

ls

Vertical Panel Joint & Fastener Locations

Vertical Panel Joint

Note: Fastener locations depend on the actual design suction loads see page 422.

Concealed panel fixing

Position of vapour seal whenrequired (Site applied)

Factory applied weather seal

Pattern A (Single Fasteners) Pattern B (Single/Double Fasteners)

Panel Module Panel Module

Direction of lay

Direction of prevailing wind

Recommended Fastener Locations

Note: Two sets of construction details have beenproduced to give the building designer flexibilitywithin the Part L2 calculation for the total buildingheat loss Alpha (a). The decision on the choice of

or details is taken bythe building designer and is determined from thePart L2 total heat loss methodology. A mixture ofboth standard and enhanced details may berequired for some projects.

STANDARD ENHANCED

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 4: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

490

Eaves Detail

Building Regulations Part L2 Thermal Data

0.25 W/m2K gutter fmin = 0.89 Y = 0.12 W/mK 0.35 W/m2K gutter fmin = 0.89 Y = 0.19 W/mK0.35 sole width 300mm and depth 150mm, values for other widths availableon request. The above values are only applicable to the components on thisdetail. Changes to the components will have an effect on the given values.

Boundary Wall Gutter

KS1000 LP/LPCB insulated roof panel

Profiled filler sealed top andbottom with gun-grade sealant

Gun-grade seal at panel joints inline with 8mm butyl

Air seal - 8mm Ø butyl rubber sealant

PIR board insulation with site applied Alfasbond firerated (FR) canister insulation to fill any gaps ifrequired to maintain continuity of insulation

6mm Ø butylrubber sealant Air seal - 6mm Ø

butyl rubber sealant

Top sheet turneddown on site withroof pitches below 4°

75mm

Factory made thermallybroken membrane linedgutter with PIR boardinsulation to 0.25 or0.35 W/m2K U-value

Eaves beamgutter support

Parapet flashing with150mm sealed buttstraps

AWP filler with gun-gradesealant

KS1000 MR/LPCBvertically laid

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 5: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

491

KS6

00/

900/

100

0

AW

P V

erti

cally

Lai

dCo

nstr

ucti

on D

etai

ls

Eaves Detail

Parapet Detail - Boundary Wall Gutter

35m

m

min

60mm

Parapet flashing with 150mm sealed butt straps

Air seal - 6mm Ø butyl rubber sealant

Parapet rail with air seal, Vapourflex tape to rail joints

Mineral fibre insulation site applied

Butyl rubber sealant

Profiled filler sealed top and bottom with gun-grade sealant

Sheeting rail

Air seal - 6mm Ø butyl rubber sealant

Mineral fibre insulation site applied

Purlin

Gutter outlet

Eaves beam gutter support

Building Regulations Part L2 Thermal Data

0.25 W/m2K gutter fmin = 0.48 Y = 1.63 W/mK0.35 W/m2K gutter fmin = 0.48 Y = 1.72 W/mK0.35 sole width 300mm and depth 150mm, values for other widths availableon request. The above values are only applicable to the components on thisdetail. Changes to the components will have an effect on the given values.

KS1000 LP/LPCBinsulated roof panel

2mm external non-thermallybroken factory made gutterwith PIR insulation to 0.25or 0.35 W/m2K U-value

KS1000 MR/LPCB wall panelvertically laid

AWP filler sealedtop and bottomwith gun-gradesealant

6mm Ø bead ofgun-grade sealant

Air seal -gun-gradesealant tomale joint

STANDARD

STANDARD

ENHANCED

Building Regulations Part L2 Thermal Data

0.25 W/m2K gutter fmin = 0.90 Y = 0.13 W/mK0.35 W/m2K gutter fmin = 0.90 Y = 0.21 W/mK0.35 sole width 300mm and depth 150mm, values for other widths availableon request. The above values are only applicable to the components on thisdetail. Changes to the components will have an effect on the given values.

ENHANCED

Site applied PIRboard insulation

Site applied Alfasbondfire rated (FR) canister

insulation

Factory made thermallybroken membrane lined

gutter with PIR boardinsulation to 0.25 or0.35 W/m2k U-value

Site applied Alfasbondfire rated (FR) canisterinsulation

Air seal - 8mmØ butyl rubber

sealant

75mm minimum

It is important that the edge of the panel isover the base of the gutter as shown

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 6: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

Eaves Detail

1000mm Centres gutter supports

Gutter Support

Mineral fibre insulation site applied

Eaves beam

Building Regulations Part L2 Thermal Data

fmin = 0.95 Y = 0.31 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

STANDARD

STANDARD

Building Regulations Part L2 Thermal Data

fmin = 0.95 Y = 0.13 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

ENHANCED

ENHANCED

Eaves beam

20mm

35mm

20mm

Gutter support 0.63mm thick doubled sided plastisol coated

Top sheet turned down on site with roof pitches below 40

9mm x 3mm butyl rubber sealant

Stitching screw fixings forgutter brackets

75mm Approx

200mm fixing centres 200mm fixing centres

Eaves Detail - External Gutter

KS1000 LP/LPCBinsulated roof panel

Gun -grade sealant at paneljoints inline with 8mm butyl

Air seal - 8mm Ø butyl rubber sealant

Air seal - 8mm Ø butyl rubber sealant

Air seal - 6mm Ø butyl rubber sealant

Air seal - 6mm Ø butyl rubber sealant

*

* Air seal - Vapourflex sealant isto be applied over any breaks insupporting secondary steelworkto give a continuous bearing face.

Mineral fibre insulation site applied

Site applied Alfasbond fire rated (FR) canister insulation

Double sidedPlastisol “Highline”type gutter

Double sidedPlastisol “Highline”type gutter

KS1000 MR/ LPCB wallpanel horizontally laid

492

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 7: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

493

KS6

00/

900/

100

0

AW

P V

erti

cally

Lai

dCo

nstr

ucti

on D

etai

ls

Eaves Detail

Double sidedplastisol “High line”type gutter

Gutter support

Purlin

Alfasbond fire rated (FR)canister insulation

Sheeting rail

75mm

200mm Fixing centres

200mm Fixing centres

Variable overhang

R/W pipe returned back tovertical sheeting & suspended

from rafter if necessarydependent on variable overhang

Gutter outlet

Flashing (internal & external) site cutaround profile of rafter as necessary

Overhanging Gutter

Note: Underside of panel to overhang to have plastisol coated liner

AWP joint filler andsilicone sealant

Air seal - 8mm Ø butylrubber sealant

Two part flashingto match panel and

cut to suit aroundpenetrating steel

Silicone seal betweensteel and flashing

Line of lap

Line of silicone to lap

Typical Flashing Detail

STANDARD

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 8: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

494

Verge Detail

Overhanging Gable

Direction of lay

Verge flashing

20mm x 3mm butyl rubber sealant

9mm x 3mm butyl rubber sealantSite applied Alfasbond fire rated (FR) canister insulation tofill any gaps if required to maintain continuity of insulation

Air seal - 8mm Ø butyl rubber sealant

Air seal - 6mm Ø beadof gun-grade sealant

Cleader angle

Purlin

FlashingSilicone sealant

Vertical sheeting rail

Flashing to suit linermaterial site cut around

purlins as necessary

Single skin soffit sheet

Cleader angle

Profiled filler sealed top and bottom

STANDARD

Building Regulations Part L2 Thermal DataPlease consult Kingspan Technical Design Bureau for thermaldata.

Variable overhang

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 9: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

495

KS6

00/

900/

100

0

AW

P V

erti

cally

Lai

dCo

nstr

ucti

on D

etai

ls

Verge Detail

Profiled filler sealed top andbottom with gun-grade sealant

Parapet rail air seal - Vapourflex to rail joints

Butyl rubber sealant

Air seal - 8mm Ø butylrubber sealant

KS1000 LP/LPCBinsulated roof panel

20mm x 3mm butylrubber sealant

Verge flashing sealed 150mm laps

Air seal - 6mm Ø butyl rubber sealant

Mineral fibre insulation

Apply edge protectionlacquer to site cut edge

Mineral fibre insulation

Parapet flashingwith 150mm sealedbutt straps

4mm Ø butyl rubbersealant

KS1000 MR/LPCBhorizontally laid

Purlin

internal ridge flashing with 150mmoverlap sealed with air seal -Vapourflex or gun-grade sealant

Air seal - 6mm Ø butyl rubber sealant

Parapet Verge Detail

Building Regulations Part L2 Thermal Data

fmin = 0.37 Y = 1.14 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

STANDARD

Building Regulations Part L2 Thermal Data

fmin = 0.44 Y = 0.89 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

ENHANCED

ENHANCED

Direction of lay

PIR board insulation with site appliedAlfasbond fire rated (FR) canisterinsulation to fill any gaps if required tomaintain continuity of insulation

PIR board insulation with site appliedAlfasbond fire rated (FR) canisterinsulation to fill any gaps if requiredto maintain continuity of insulation

STANDARD

ENHANCED

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 10: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

496

Verge Detail

Wall Cladding (Start of roof sheeting)

Wall Cladding (Start of roof sheeting)

Direction of lay

Verge flashing with 150mm sealed butt straps

20mm x 3mm butyl rubber sealant

Air seal - 8mm Ø butyl rubber sealant

Air seal - 6mm Ø bead of gun-grade sealant

Gable rafter

4mm Ø butyl rubber sealant

Mineral fibre insulation site applied

Cleader angle by steel sub-contractor with air seal Vapourflex sealant applied at joints

KS1000 LP/LPCB insulated roof panel

KS1000 MR/LPCB insulatedwall panel horizontally laid

Building Regulations Part L2 Thermal Data

fmin = 0.96 Y = 0.18 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

Purlin

STANDARD

STANDARD

Direction of lay

Verge flashing with 150mm sealed butt straps

20mm x 3mm butyl rubber sealant

Purlin

Air seal - 8mm Ø butyl rubber sealant

Air seal - 6mm Ø bead of gun-grade sealant

Gable rafter

4mm Ø butyl rubber sealant

PIR board insulation with site applied Alfasbond fire rated (FR) canisterinsulation to fill any gaps if required to maintain continuity of insulation

Cleader angle by steel sub-contractor with air seal Vapourflex sealant applied at jointsKS1000 LP/LPCB insulated roof panel

KS1000 MR/LPCB insulatedwall panel horizontally laid

Building Regulations Part L2 Thermal Data

fmin = 0.96 Y = 0.01 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

ENHANCED

ENHANCED

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 11: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

497

KS6

00/

900/

100

0

AW

P V

erti

cally

Lai

dCo

nstr

ucti

on D

etai

ls

Curved Eaves

150mm Max

Eaves flashing

9mm x 3mm butyl rubber

Curved KS1000 MR/LPCBinsulated wall panelhorizontally laid

Purlin

4mm Ø butyl rubber sealant

KS1000 MR/LPCB insulated wall panel vertically laid

Required angle

Gutter outlet

50x50mm curved steel panel supports to suit wind suction loads

9mm x 3mm Butyl rubber sealant

Curved panel single spanningbetween curved support. Panelspan dependant upon loadings

Through fix fastener at 500mm ctrs

Boundary Wall Gutter

Feature flashing4mm Ø butyl rubber sealant

50x50mm angle curved steel supports

3.0m Max. vertical joint 3.0m Max. vertical joint

Flat headed fasteners

10

Vertical Joint

Air seal - EPDM bubble gasket 95x10mm. Kingspan (Ref: VJ2)

Alfasbond fire rated (FR) canister insulation

Air seal - 8mm Øbutyl rubber sealant

Air seal - 6mm bead of gun grade sealant

Air seal - 6mm bead of gun grade sealant

2mm external non-thermally brokenfactory made gutter with PIR insulation

to 0.25 or 0.35 W/m2K U-value

PIR board insulation with site applied Alfasbondfire rated (FR) canister insulation to fill any gaps if

required to maintain continuity of insulation

Building Regulations Part L2 Thermal Data

0.25 W/m2K gutter fmin = 0.74 Y = 2.65 W/mK0.35 W/m2K gutter fmin = 0.71 Y = 2.80 W/mK0.35 sole width 300mm and depth 150mm, values for other widths availableon request. The above values are only applicable to the components on thisdetail. Changes to the components will have an effect on the given values.

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 12: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

498

Corner Detail

Horizontal sheeting rail

Site cut vertical sheeting

Horizontal sheeting rail

Internal corner flashing

External corner flashing

9mm x 3mm butyl rubber sealant

Flat head fasteners

Direction of lay

Standard Internal Corner

Direction of lay

Site applied insulation by others

Building Regulations Part L2 Thermal Data

fmin = 0.91 Y = 0.00 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

Air seal - 4mm bead of gun grade sealant

Air seal - 4mm beadof gun grade sealant

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 13: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

499

KS6

00/

900/

100

0

AW

P V

erti

cally

Lai

dCo

nstr

ucti

on D

etai

ls

Corner Detail

Top hat flashing

Flat head fastener

4mm Ø butyl rubber sealant

Corner column

Horizontal sheeting rail

Square corner insulated panel

Horizontal sheeting rail

External Pre-Formed Corner

Internal flashing

Corner Stub

Direction of lay

Direction of lay

Alfasbond FR canister applied insulation

Building Regulations Part L2 Thermal Data

fmin = 0.96 Y = 0.01 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

Air seal - 4mm bead of gun grade sealant

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 14: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

500

Corner Detail

1000

mm

Mod

ule

446m

m radiu

s Max

.

150m

m P

anel

flat

1000mm Module

150mm Panel flat

Curved wall panel

Corner column

Flat head fastener

Horizontal sheeting rail

Gable column

4mm Ø butyl rubber sealant

Top hat flashing

Internal flashing

Air seal - 4mm bead of gun grade sealant

External Curved

Curved secondarysteelwork positioned toresist design wind loads

Directionof lay

Direction of lay

Site appliedinsulation byothers

Building Regulations Part L2 Thermal Data

fmin = 0.96 Y = 0.03 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 15: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

501

KS6

00/

900/

100

0

AW

P V

erti

cally

Lai

dCo

nstr

ucti

on D

etai

ls

Corner Detail

Cranked wall panel

External Cranked

1000

mm

Mod

ule

150m

m P

anel

flat

1000mm Module

150mm Panel flat

Direction of lay

Directionof lay

Site appliedinsulation byothers

Corner column

Flat head fastener

Horizontal sheeting rail

Horizontal sheeting rail

Gable column

4mm Ø butyl rubber sealant

Top hat flashing

Internal flashing

Air seal - 4mm bead of gun grade sealant

Building Regulations Part L2 Thermal Data

fmin = 0.96 Y = 0.03 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

Cranked secondary steelwork positionedto resist design wind loads

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 16: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

502

Corner Detail

Corner column

Horizontal sheeting rail

Horizontal sheeting railInternal corner flashing

4mm Ø butyl rubber sealant

Flat headed fastener

Edge of vertical sheeting site cut

External corner flashing

4mm Ø butyl rubber sealant

External Corner Flashing

Corner stub

Direction of lay

Direction of lay

Mineral fibre insulation site applied

Air seal - 6mm bead ofgun grade sealant

Air seal - 6mm bead of gun grade sealant

STANDARD Building Regulations Part L2 Thermal Data

fmin = 0.91 Y = 0.04 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

Corner column

Horizontal sheeting rail

Horizontal sheeting railInternal corner flashing

4mm Ø butyl rubber sealant

Flat headed fastener

Edge of vertical sheeting site cut

External corner flashing

4mm Ø butyl rubber sealant

External Corner Flashing

Corner stub

Direction of lay

Direction of lay

Air seal - 6mm bead ofgun grade sealant

Air seal - 6mm bead of gun grade sealant

Building Regulations Part L2 Thermal Data

fmin = 0.94 Y = 0.04 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

ENHANCED

Canister applied (FR) fire rated insulation

PIR board insulation with site appliedAlfasbond fire rated (FR) canisterinsulation to fill any gaps if requiredto maintain continuity of insulation

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 17: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

503

KS6

00/

900/

100

0

AW

P V

erti

cally

Lai

dCo

nstr

ucti

on D

etai

ls

Drip Detail

Drip Detail

Optional internal closure flashingto mask insulation from view

Stanchion

Sheeting rail

Air seal - Continuous bead of gun-grade sealant

Drip flashing

Air seal - Gun-grade sealant at male joint

Air seal - Gun-grade sealant at male joint

Closure flashing with lap joints air sealed(Vapourflex sealant applied at joints)

PIR board insulation with site applied Alfasbondfire rated (FR) canister insulation to fill any gaps

if required to maintain continuity of insulation

Building Regulations Part L2 Thermal Data

fmin = 0.41 Y = 0.52 W/mKThe appropriate Y value for the brickwork or blocks must be added to theabove Y value to obtain the total heat loss through this junction details.The above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

Optional internal closure flashingto mask insulation from view

Stanchion

Sheeting rail

Air seal - Continuous bead of gun-grade sealant

Drip flashing

Air seal - Gun-grade sealant at male joint

Air seal - Gun-grade sealant at male joint

Closure flashing with lap joints air sealed(Vapourflex sealant applied at joints)

80mm thick PIR board insulation with siteapplied Alfasbond fire rated (FR) canister

insulation to fill any gaps if required

Building Regulations Part L2 Thermal Data

fmin = 0.41 Y = 0.52 W/mKThe appropriate Y value for the brickwork or blocks must be added to theabove Y value to obtain the total heat loss through this junction details.The above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

STANDARD

Drip Detail

ENHANCED

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 18: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

504

Lean-to-Roof Detail

KS1000 MR/LPCB horizontally laid

Sheeting rail

Air seal - 6mm Ø bead of gun-grade sealant

Outer sheet turned up with roof slopes below 40

Cover cap

Bead of non-curing gun-grade sealant

Profiled filler set back 80 to100mm to prevent bird attack

Building Regulations Part L2 Thermal Data

fmin = 0.61 Y = 0.87 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

Vertical Cladding

2 No. runs of non-curinggun-grade sealant

Air seal - 8mm Ø butyl rubber sealant

Purlin

Rafter

KS1000 LP/LPCB insulated roof panel

PIR insulation board with Alfasbond (FR)canister applied insulation to fill any gaps ifrequired to maintain continuity of insulation

Internal ridge flashing with 150mmoverlap sealed with air seal - Vapourflex

or gun-grade sealant

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 19: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

505

KS6

00/

900/

100

0

AW

P V

erti

cally

Lai

dCo

nstr

ucti

on D

etai

ls

Abutment Details

Flush Abutment to Brickwork

Air seal - continuous bead of gun-grade sealant

Flat headed fastener at 500mm maximum centres Polyethylene backing rod with silicone sealant by others

Site cut panel to suit

Sheeting rail

Closure flashing with 100mmair sealed overlapped joints

Air seal - 4mm Ø bead of gun-grade sealant

KS1000 MR/LPCB vertically laid

4mm Ø butyl rubber sealant

Trim flashing

Alfasbond FR canister applied insulation to fill anygaps if required to maintain continuity of insulation

Proud Abutment to Brickwork

Air seal - continuous bead of gun-grade sealant

Flat headed fastener at 500mm maximum centres

Polyethylene backing rod with silicone sealant by others

Site cut panel to suit

Sheeting rail

Closure flashing with 100mmair sealed overlapped joints

Air seal - 4mm Ø bead of gun-grade sealant

KS1000 MR/LPCB vertically laid

4mm Ø butyl rubber sealant

Alfasbond FR canister applied insulation to fill anygaps if required to maintain continuity of insulation

Trim flashing

Building Regulations Part L2 Thermal Data

fmin = 0.96 Y = 0.03 W/mKThe appropriate Y value for the brickwork or blocks must be added to theabove Y value to obtain the total heat loss through this junction details.The above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

Building Regulations Part L2 Thermal Data

fmin = 0.86 Y = 0.29 W/mKThe appropriate Y value for the brickwork or blocks must be added to theabove Y value to obtain the total heat loss through this junction details.The above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

Horizontal sheeting rail

Silicone sealant

9mm x 3mm butyl rubber sealant

Abutment flashing

Main structural support

Horizontal sheeting rail

Silicone sealant

9mm x 3mm butyl rubber sealant

Abutment flashing

Main structural support

Internal liner flashing

Site applied insulationby others

Curtain walling glazing by others

Abutment to Curtain Walling

Direction of lay

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 20: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

506

Vertical to Horizontal Break

AWP Vertical to Horizontal Joint

Air seal - gun-grade sealant at male panel joint

Alfasbond FR canister applied insulation

Drip flashing

KS1000 MR/LPCB horizontally laid

Air seal - 6mm Ø bead of gun-grade sealant

Air seal - 6mm Ø bead of gun-grade sealant

Air seal - Vapourflex sealant applied over joints in supports

KS1000 MR/LPCB vertically laid

4mm Ø butyl rubber sealant

Building Regulations Part L2 Thermal Data

fmin = 0.69 Y = 1.01 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

KS1000 MR/LPCB Vertically laid

KS1000 MR/LPCB Vertically laid

Air seal - Vapourflex sealant applied over joints in supports

Air seal - 6mm bead of gun grade sealant

Air seal - 6mm bead of gun grade sealant

Air seal - Gun grade sealant at male panel joint

Air seal - Gun gradesealant at male panel joint

AWP joint filler and gun grade sealant

Drip flashing

4mm Ø butyl rubber sealant

Alfasbond FR canister applied insulation

Stack Joint

Building Regulations Part L2 Thermal Data

fmin = 0.69 Y = 1.01 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 21: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

507

KS6

00/

900/

100

0

AW

P V

erti

cally

Lai

dCo

nstr

ucti

on D

etai

ls

Expansion Joint Detail

Horizontal sheeting rail

External expansion flashing

Internal liner flashing

Site cut panels to suitbay centres if necessary

Flat head fasteners

Column

Slotted holes in rail cleat toaccommodate expansion

4mm Ø butyl rubber sealant

Site applied insulation by others

External expansion flashing

Internal liner flashing

Standard fastener

4mm Ø butyl rubber sealant

Direction of lay

Site applied insulation by others

Air Seal - 6mm bead of gun grade sealant

Air Seal - 6mm beadof gun grade sealant

Alternative Joint Detail

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 22: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

508

Panel Soffit Detail

Dimension to suit panel module

Soffit horizontally laid

4mm Ø butyl rubber sealant

4mm Ø butyl rubber sealantExternal soffit flashing

PIR board insulation

Head flashing

Vertical sheeting rail

Vertical sheeting rail

Variable dimension

Air Seal - 6mm Ø bead ofgun grade sealant

Air Seal - 6mm Ø bead ofgun grade sealant

PIR board insulation

Internal flashing with100mm sealed lap joints

4mm Ø butylrubber sealant

Air Seal - bridging sealgun grade sealant

PIR board insulation

Drip channel with air seal- Vapourflex tape to joints

Air Seal - 6mm Ø beadof gun grade sealant

Air Seal - bridging sealgun grade sealant

Soffit Laid Horizontally

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 23: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

509

KS6

00/

900/

100

0

AW

P V

erti

cally

Lai

dCo

nstr

ucti

on D

etai

ls

Soffit Detail

Variable soffit width

Closure flashing

Continuous bead ofgun grade sealant

External soffit flashing

9mm x 3mm butyl rubber sealant

PIR board insulation

Drip flashing

4mm Ø butylrubber sealant

Air Seal - 6mm beadof gun grade sealant

Air Seal - bridging sealgun grade sealant

Galv. support angle

Alfasbond FR canisterinsulation applied priorto fixing soffit flashing

Dim

ensi

on a

sre

quire

d

Drip flashing

Rivet fix

Site cut panel

Cover Strip for Site Cut Panels

Flat head fastenerat 500mm centres

Cover strip to conceal sitecut panel edge if required(Cut back to show flathead fastener)

Cladding to Brickwork

Building Regulations Part L2 Thermal Data

fmin = 0.51 Y = 1.49 W/mKThe above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 24: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

510

Porthole Window Details

Varia

ble

heig

ht

100m

m

Windows may be positioned in adjacent panels if required

800mm Max.

Window Positions

100m

m

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 25: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

511

KS6

00/

900/

100

0

AW

P V

erti

cally

Lai

dCo

nstr

ucti

on D

etai

ls

Porthole Window Details

abc ac

abc

abc ac

ac

750 750 750

1500

1500

1200

Types of window availablea – Horizontal pivotb – Top hungc – Fixed

1200

750

750

Standard Range

Typical Sections

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 26: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

512

Window Details

Window Jamb Detail

Window Head and Sill Detail

Window opening

Jamb steelwork

Window unit by others

Polyethylene backing rod withsilicone sealant by window installer

Mineral fibre insulation site applied

4mm Ø butyl rubber sealant

Site cut panel

Win

dow

dep

th to

sui

t pan

el m

odul

e

Window support rail

Mineral fibre insulation site applied

Air seal - 6mm beadof gun-grade sealant

Optional internal head flashing

Optional internal head flashing

Air seal - 6mm bead of gun-grade sealant

Mineral fibre insulation site applied

Air seal - 6mm bead of gun-grade sealant

External jamb flashing with no connection to internal flashing

External soffit flashing with noconnection to internal flashing

Polyethylene backing rod withsilicone sealant by window installer

Head flashing

Window unit by others

Window sill flashing with 3° slope to facilitatedrainage (no connection to internal flashing)

4mm Ø butyl rubber sealant

Building Regulations Part L2 Thermal Data

fmin = 0.49 Y = 0.97 W/mKThe appropriate Y value for the window system must be added to theabove Y value to obtain the total heat loss through this junction detail.

The above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

Building Regulations Part L2 Thermal Data

fmin = 0.67 Y = 0.48 W/mKThe appropriate Y value for the window system must be added to theabove Y value to obtain the total heat loss through this junction detail.

The above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

Building Regulations Part L2 Thermal Data

fmin = 0.62 Y = 0.67 W/mKThe appropriate Y value for the window system must be added to theabove Y value to obtain the total heat loss through this junction detail.

The above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

STANDARD

STANDARD

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 27: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

513

KS6

00/

900/

100

0

AW

P V

erti

cally

Lai

dCo

nstr

ucti

on D

etai

ls

Window Details

Window Jamb Detail

Window Head and Sill Detail

Window opening

Jamb steelwork

Window unit by others

Internal jamb flashing with no connection to external flashing

Polyethylene backing rod withsilicone sealant by window installer

Site applied 25mm thick PIR board insulation withAlfasbond fire rated (FR) canister insulation filling gaps

to maintain insulation prior to placing board

4mm Ø butyl rubber sealant

Site cut panel

Win

dow

dep

th to

sui

t pan

el m

odul

e

Window support rail

Internal head flashing (optional)with no connection to external

soffit flashing

Ferrules used to fix window

Air seal - 6mm beadof gun-grade sealant

Optional internal head flashing

Air seal - 6mm bead of gun-grade sealant

PIR board insulation

Air seal - 6mm bead of gun-grade sealant

External jamb flashing with no connection to internal flashing

External soffit flashing with noconnection to internal flashing

Polyethylene backing rod withsilicone sealant by window installer

Site applied Alfasbond firerated (FR) canister insulation

Head flashing

Window unit by others

4mm Ø butyl rubber sealant

Window sill flashing with 3° slope to facilitatedrainage (no connection to internal flashing)

25mm thick PIR board insulation

Building Regulations Part L2 Thermal Data

fmin = 0.51 Y = 0.62 W/mKThe appropriate Y value for the window system must be added to theabove Y value to obtain the total heat loss through this junction detail.

The above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

Building Regulations Part L2 Thermal Data

fmin = 0.93 Y = 0.10 W/mKThe appropriate Y value for the window system must be added to theabove Y value to obtain the total heat loss through this junction detail.

The above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

Building Regulations Part L2 Thermal Data

fmin = 0.96 Y = 0.08 W/mKThe appropriate Y value for the window system must be added to theabove Y value to obtain the total heat loss through this junction detail.

The above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

ENHANCED

ENHANCED

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 28: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

514

Personnel Door Details

Door Jamb Detail A-A

+2100mm

F.F.L. 0.00mm

900mm

AA

B

B

Door frame by others

Pressed metalbase channel orRSA by others

Personnel Door Detail - (Door Head Panel Site Cut)

Expanding type anchor fixing

Note: For openingoutward door ensure door head flashing issufficiently high enoughto clear top of door

Door Head Detail B-B

External soffit flashing with noconnection to internal flashing

Ferrules used to fix door

Door head flashing

Galvanised door head

Optional internalhead flashing

4mm Ø butyl rubber sealant

25mm thick PIRboard insulation

4mm Ø butylrubber sealant

Polyethylene backing rod withsilicone sealant by door installer

External jamb flashing with noconnection to internal flashing

Air seal - 6mm Ø beadof gun-grade sealant

Building Regulations Part L2 Thermal Data

fmin = 0.96 Y = 0.08 W/mKThe appropriate Y value for the door system must be added to the above Y value to obtain the total heat loss through this junction detail.

The above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

Building Regulations Part L2 Thermal Data

fmin = 0.51 Y = 0.62 W/mKThe appropriate Y value for the door system must be added to the aboveY value to obtain the total heat loss through this junction detail.

The above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

Galvanised door post by steelsub-contractor with Vapourflexsealant applied to joints

Internal jamb flashingwith no connection toexternal flashing

PIR board insulation

Air seal - 6mm beadof gun-grade sealant

Optional internalhead flashing with no

connection toexternal soffit flashing

Door & frame by othersfixed to steel support frame

25mm thick PIR boardinsulation with site applied

Alfasbond fire rated (FR)canister insulation filling gaps to

maintain insulation prior toplacing board

ENHANCED ENHANCED

ENHANCED

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 29: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

515

KS6

00/

900/

100

0

AW

P V

erti

cally

Lai

dCo

nstr

ucti

on D

etai

ls

Personnel Door Details

Door Jamb Detail A-A

+2100mm

F.F.L. 0.00mm

900mm

AA

B

B

Door frame by others

Pressed metalbase channel orRSA by others

Personnel Door Detail - (Door Head Panel Site Cut)

Expanding type anchor fixing

Note: For openingoutward door ensure door head flashing issufficiently high enoughto clear top of door

Door Head Detail B-B

Door head flashing

Galvanised door head

Optional internalhead flashing

4mm Ø butyl rubber sealant

4mm Ø butylrubber sealant

Polyethylene backing rod withsilicone sealant by door installer

Polyethylene backingrod with silicone sealant

by door installer

External jamb flashing with noconnection to internal flashing

Air seal - 6mm Ø beadof gun-grade sealant

Building Regulations Part L2 Thermal Data

fmin = 0.60 Y = 0.80 W/mKThe appropriate Y value for the door system must be added to the above Y value to obtain the total heat loss through this junction detail.

The above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

Building Regulations Part L2 Thermal Data

fmin = 0.44 Y = 0.91 W/mKThe appropriate Y value for the door system must be added to the aboveY value to obtain the total heat loss through this junction detail.

The above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

Galvanised door post by steelsub-contractor with Vapourflexsealant applied to joints

Mineral fibre insulationsite applied

Air seal - 6mm beadof gun-grade sealant

Air seal - Bridging seal tomale joint gun-grade sealant

Door & frame by othersfixed to steel support frame

Mineral fibre insulationsite applied

STANDARD STANDARD

STANDARD

Door & frame by othersfixed to steel support frame

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 30: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

516

Up and Over Door Details

Drum

Optional - internal head flashing

PIR board insulation

RSC door post

60mm return to soffit flashing

Door guide with air seal

Roller guide supportedfrom main structureSe

e do

or m

anuf

actu

rers

det

ails

for h

eigh

t req

uire

dC

lear

doo

r hei

ght

Variable slope

Air Seal - 6mm Ø beadof gun grade sealant

Air Seal - 6mm Ø beadof gun grade sealant

Air Seal - 6mm Ø beadof gun grade sealant

Air Seal - bridging seal tomale joint gun grade sealant

Head flashing

4mm Ø butyl sealant

4mm Ø butyl sealant 4mm Ø butyl sealant

PIR board insulation

External soffit flashing

Site cut panel

External jamb flashing

Clear door width

70mm PIR board insulation with Alfasbondfire rated (FR) canister insulation filling gapsto maintain insulation prior to placing board

RSC door posts by steel sub-contractorwith Vapourflex sealant applied at joints

Door jamb flashing

Door guide with air seals

Section Through Door Head

ENHANCED

Section Through Door Jamb

ENHANCED

Building Regulations Part L2 Thermal Data

fmin = 0.51 Y = 0.63 W/mKThe appropriate Y value for the door system must be added to the above Y value to obtain the total heat loss through this junction detail.

The above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

Building Regulations Part L2 Thermal Data

fmin = 0.74 Y = 0.71 W/mKThe appropriate Y value for the door system must be added to the above Y value to obtain the total heat loss through this junction detail.

The above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 31: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

517

KS6

00/

900/

100

0

AW

P V

erti

cally

Lai

dCo

nstr

ucti

on D

etai

ls

Up and Over Door Details

Drum

Optional - internal head flashing

Mineral fibre insulation site applied

Mineral fibre insulation site applied

RSC door post

60mm return to soffit flashing

Door guide with air seal

Roller guide supportedfrom main structure

See

door

man

ufac

ture

rs d

etai

ls fo

r hei

ght r

equi

red

Cle

ar d

oor h

eigh

t

Variable slope

Air Seal - 6mm Ø beadof gun grade sealant

Sheeting rail Sheeting rail

Air Seal - 6mm Ø bead of gun grade sealant

Air Seal - bridging seal tomale joint gun grade sealant

Head flashing

4mm Ø butyl sealant

4mm Ø butyl sealant 4mm Ø butyl sealant

External soffit flashing

Site cut panel

External jamb flashing

Clear door width

RSC door posts

Door by others

Internal cleader angle by steel sub-contractorwith Vapourflex sealant applied at joints

Door guide by others Door guide by others

Section Through Door Head

Section Through Door Jamb

Building Regulations Part L2 Thermal Data

fmin = 0.30 Y = 0.68 W/mKThe appropriate Y value for the door system must be added to the above Y value to obtain the total heat loss through this junction detail.

The above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

STANDARD

STANDARD

Building Regulations Part L2 Thermal Data

fmin = 0.37 Y = 1.70 W/mKThe appropriate Y value for the door system must be added to the above Y value to obtain the total heat loss through this junction detail.

The above values are only applicable to the components on this detail.Changes to the components will have an effect on the given values.

Internal closureflashing

Internal closureflashing

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 32: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

518

Fixed Wall Louvre Details

Galvanised pressed metal supportsconnected to sheeting rails

Bird mesh screen/insect screen

Varia

ble

Sill flashing

Site cut panel

Head flashing

Ledger angle

Scapa Tapes 0004 silicone seal

Soffit flashing

9mm x 3mm Butyl rubber sealant

Silicone sealant by others

Horizontal sheeting rail

Section Through Head and Sill

Double 6mm Ø butyl rubber sealant

6mm Ø Butyl rubber sealant9mm x 3mm Butyl rubber sealant

Louvre by others inserted as aunit from the inside

AWP joint filler and silicone sealant

Galvanised pressed metal supportsconnected to sheeting rails

Silicone sealant by others

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 33: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

519

KS6

00/

900/

100

0

AW

P V

erti

cally

Lai

dCo

nstr

ucti

on D

etai

ls

Fixed Wall Louvre Details

9mm x 3mmbutyl rubbersealant

6mm Ø butylrubber sealant

Silicone sealant by others

Dimension to suit panel module

Jamb flashing

Jamb Detail

9mm x 3mm butylrubber sealant

Site cut panel

Variable

Jamb flashing

Flat head fastener

Galvanised pressed metal supportsconnected to sheeting rails

Flat head fastener

6mm Ø butyl rubber sealant

6mm Ø butylrubber sealant

Silicone sealant by others

6mm Ø butylrubber sealant

Galvanised pressed metal supportsconnected to sheeting rails

Jamb Detail (Site Cut Panel)

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 34: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

520

Wall Extractor Details

Pipe/ducting by others

6mm Ø Butyl rubber sealant

Hole site cut toaccommodate pipe/ducting etc.

Internal cover stripto match liner material

Dektite” (E.P.D.M.) flexible pipe flashing or similar by others

Standard Temperature

“Dektite” (Silicon) flexible pipe flashing or similar tosuit high temperature conditions by others

6mm Ø Butyl rubber sealant

Hole site cut toaccommodate pipe/ducting etc.

Galvanised soaker

Pipe/ducting by others

Internal cover strip to match liner material

Site applied insulation/noncombustible material by others

High Temperature

Note: Maximum hole size to be 300mm square or diameter, penetrations greater will require additional supporting steel

Pipe/ducting by others

Hole site cut to accommodatepipe/ducting etc.

Alternative Standard Temperature

Insulated panel

Moulded GRP pipe outlet(factory produced)

GRP insitu weathering systembonded to panels external sheet,colour to match external panel

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 35: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

521

KS6

00/

900/

100

0

AW

P V

erti

cally

Lai

dCo

nstr

ucti

on D

etai

ls

Panel Bearer Details

44.5

10

17

100°

9.5mm Ø Bar

2 Holes6mmdiameter

“X”

“X”

12.5175

2515025

A

A

12.5

200

17

1

Pane

l thi

ckne

ss

Panel Bearer

Section A-A Location of Bearer within Female Section of Panel

Note: All dimensions in millimetres.Panel bearer fixing centres 1500mm maximum.

One number panel bearer located at each end of each panel

Material: 2.5mm thick mild steel

Finish: BZP and clearBS : 1706 1990 Ff Zn 51A

Panel Thickness Dimension “X”

45mm 24mm

50mm 29mm

60mm 39mm

70mm 49mm

80mm 59mm

100mm 79mm

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 36: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

522

Pre-Formed Units

Square Corner

Q

Dim. ADim. C

Arc B

Radius R

Leng

th ‘L

90°

Dim. A Dim. B

Leng

th ‘L

All dimensions in millimetres (mm)

Dim. A x Arc B x Dim. C 350 x 300 x 350 (1000 Module)

Dim. A x Arc B x Dim. C 300 x 300 x 300 (900 Module)

Dim. A x Arc B x Dim. C 150 x 300 x 150 (600 Module)

Maximum Leg Length (Angle qq = 90°)

Dim. A x Arc B x Dim. C 150 x 700 x 150 (1000 Module)

Dim. A x Arc B x Dim. C 150 x 600 x 150 (900 Module)

Dim. A x Arc B x Dim. C 150 x 300 x 150 (600 Module)

Minimum Leg Length (Angle qq = 90°)

7000 Max

150 Min

Panel Length (L)

7000 Max

150 Min

Panel Length (L)

Radius R. 446 (1000 Module)

Radius R. 382 (900 Module)

Maximum Radius (Angle qq = 90°)

Radius R. 191 (All Modules)

Minimum Radius (Angle qq = 90°)

Dim. A x Dim. B 500 x 500 (1000 Module)

Dim. A x Dim. B 450 x 450 (900 Module)

Dim. A x Dim. B 300 x 300 (600 Module)

Maximum Equal Leg

Dim. A x Dim. B 850 x 150 (1000 Module)

Dim. A x Dim. B 750 x 150 (900 Module)

Dim. A x Dim. B 450 x 150 (600 Module)

Minimum Unequal Leg

Curved Corner

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 37: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

523

KS6

00/

900/

100

0

AW

P V

erti

cally

Lai

dCo

nstr

ucti

on D

etai

ls

Pre-Formed Units

Double Corner

Chamfered Corner

QQ

Dim. A Dim. C

Dim. B

Leng

th ‘L

Q1

Q2

Dim. ADim. CDim. B

Leng

th ‘L

All dimensions in millimetres (mm)

7000 Max

150 Min

Panel Length (L)

7000 Max

150 Min

Panel Length (L)

Dim. A x Dim. B x Dim. C 425 x 150 x 425 (1000 Module)

Dim. A x Dim. B x Dim. C 375 x 150 x 375 (900 Module)

Dim. A x Dim. B x Dim. C 225 x 150 x 225 (900 Module)

Maximum Leg Length

179° - Max

70° - Min

Internal Angle qq

Dim. A x Dim. B x Dim. C 150 x 700 x 150 (1000 Module)

Dim. A x Dim. B x Dim. C 100 x 700 x 100 (900 Module)

Dim. A x Dim. B x Dim. C 150 x 600 x 150 (900 Module)

Minimum Leg Length

Dim. A x Dim. B x Dim. C 425 x 150 x 425 (1000 Module)

Dim. A x Dim. B x Dim. C 375 x 150 x 375 (900 Module)

Dim. A x Dim. B x Dim. C 225 x 150 x 225 (900 Module)

Maximum Leg Length

179° - Max

70° - Min

Internal Angle qq

Dim. A x Dim. B x Dim. C 150 x 700 x 150 (1000 Module)

Dim. A x Dim. B x Dim. C 150 x 600 x 150 (900 Module)

Dim. A x Dim. B x Dim. C 150 x 300 x 150 (900 Module)

Minimum Leg Length

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info

Page 38: Construction Details 489 - Barbour Product Search · Gutter support 0.63mm thick doubled sided plastisol coated Top sheet turned down on site with roof pitches below 40 9mm x 3mm

524

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.info