Saint Petersburg, 2016

Contact GSM-16Terminals and Connections

Page 2: Contact GSM-16 - RITM · terminals on your Contact GSM 5-2, or keypad power terminals (+U, GND), or +12V, GND terminals in your power supply. • If you want to use a resistive hard-wired

www.ritm.ru/en 2

Contact GSM-16. Terminals and Connections.

List of contents

Redundant power supply connection 3

Wired zones connection 4

Touch memory reader connection 6

Wired and LCD keypad connection 9

Additional items connection 12

Relay connection 14

Page 3: Contact GSM-16 - RITM · terminals on your Contact GSM 5-2, or keypad power terminals (+U, GND), or +12V, GND terminals in your power supply. • If you want to use a resistive hard-wired

www.ritm.ru/en 3

Contact GSM-16. Terminals and Connections.

Redundant power supply connection

You should apply the +12V redundant power supply to your device. Connect your device, using +12V and GND terminals to +12V and GND terminals of the redundant power supply.

Our redundant power supply (BPM1205N, BPM 12V 5A, BPM 12V 7A) has a CPW terminal designed for connection of main power monitoring bus. You can connect the CPW from your device to the CPW terminal of the power supply.

Make sure to disconnect the redundant power supply from the power, when you connect it to your device!

Page 4: Contact GSM-16 - RITM · terminals on your Contact GSM 5-2, or keypad power terminals (+U, GND), or +12V, GND terminals in your power supply. • If you want to use a resistive hard-wired

www.ritm.ru/en 4

Contact GSM-16. Terminals and Connections.

Wired zones connection

Connect your wired sensors to “+” and “-” terminals of your device.

• If you use sensors, powered only by zone terminals, you do not need any other connections.

• If you use sensors, which require an additional power supply, you can apply the voltage from 12 V & GND terminals on your Contact GSM 5-2, or keypad power terminals (+U, GND), or +12V, GND terminals in your power supply.

• If you want to use a resistive hard-wired zone, connect your sensors, according to the data sheets of your sensors. You can use resistors from 2 Ohm, up to 10 Ohm, and you can make a “fine-tuning” in the configuration software.

Page 5: Contact GSM-16 - RITM · terminals on your Contact GSM 5-2, or keypad power terminals (+U, GND), or +12V, GND terminals in your power supply. • If you want to use a resistive hard-wired

www.ritm.ru/en 5

Contact GSM-16. Terminals and Connections.

Open the “Loop properties” section in the configuration software.

You can configure each wired zone separately:

• Loop type (dry contact / resistive). If you will choose resistive zones, you can move the slider of the resistance.

• Number of zone• Normal condition (closed circuit / opened circuit)• Zone type• Number of Area• Event in case of triggering

Save changes, before you leave the current page.

Page 6: Contact GSM-16 - RITM · terminals on your Contact GSM 5-2, or keypad power terminals (+U, GND), or +12V, GND terminals in your power supply. • If you want to use a resistive hard-wired

www.ritm.ru/en 6

Contact GSM-16. Terminals and Connections.

Touch memory reader connection

Connect the Touch Memory reader to your device, by using the TM and GND terminals, according to the Data sheet of your TM reader. Also you can connect the LED of your TM reader to LED terminal of your Contact GSM-16.

Go to the “Touch memory keys” section in the configuration software.

Choose the “Touch Memory reader” in first field.

If you need, choose the indication of area status with external LED of Touch Memory reader. Choose areas for arming by Touch Memory reader.

Page 7: Contact GSM-16 - RITM · terminals on your Contact GSM 5-2, or keypad power terminals (+U, GND), or +12V, GND terminals in your power supply. • If you want to use a resistive hard-wired

www.ritm.ru/en 7

Contact GSM-16. Terminals and Connections.

Go to Touch Memory keys section. There are two ways to add your touch memory key to your Contact GSM-16.

Page 8: Contact GSM-16 - RITM · terminals on your Contact GSM 5-2, or keypad power terminals (+U, GND), or +12V, GND terminals in your power supply. • If you want to use a resistive hard-wired

www.ritm.ru/en 8

Contact GSM-16. Terminals and Connections.

You can apply your key to the Touch Memory reader and click “add key” to read the number of key and add the key automatically. After that you can choose the areas for arming by this Touch Memory key.

You can also add it manually if you know the code of your key. Click “Add manually” and type your code into the “Key code” field. Choose the areas for arming by this Touch Memory key

Page 9: Contact GSM-16 - RITM · terminals on your Contact GSM 5-2, or keypad power terminals (+U, GND), or +12V, GND terminals in your power supply. • If you want to use a resistive hard-wired

www.ritm.ru/en 9

Contact GSM-16. Terminals and Connections.

Wired and LCD keypad connection

Connect your wired keypad as shown on the picture.

Page 10: Contact GSM-16 - RITM · terminals on your Contact GSM 5-2, or keypad power terminals (+U, GND), or +12V, GND terminals in your power supply. • If you want to use a resistive hard-wired

www.ritm.ru/en 10

Contact GSM-16. Terminals and Connections.

Connect your LCD keypad as shown on the picture.

Go to the “Keypads” section in the configuration software.

Wired keypad should be already connected to your device.

Click “add” and your keypad will be connected automatically. You will see it in the list.

Page 11: Contact GSM-16 - RITM · terminals on your Contact GSM 5-2, or keypad power terminals (+U, GND), or +12V, GND terminals in your power supply. • If you want to use a resistive hard-wired

www.ritm.ru/en 11

Contact GSM-16. Terminals and Connections.

Go to User codes page.

Here you can make codes to control your areas from the keypad.

Page 12: Contact GSM-16 - RITM · terminals on your Contact GSM 5-2, or keypad power terminals (+U, GND), or +12V, GND terminals in your power supply. • If you want to use a resistive hard-wired

www.ritm.ru/en 12

Contact GSM-16. Terminals and Connections.

Additional items connection

You can connect some additional items (i.e. siren, relay, etc.) to the terminals −OUT1+, −OUT2+, −OUT3+.

You have to use the external SPK circuit board (connect the -IN+ terminals of SPK circuit board to - OUT + terminals of Contact GSM-16). After that, connect your additional devices to the “Device” terminals.

Page 13: Contact GSM-16 - RITM · terminals on your Contact GSM 5-2, or keypad power terminals (+U, GND), or +12V, GND terminals in your power supply. • If you want to use a resistive hard-wired

www.ritm.ru/en 13

Contact GSM-16. Terminals and Connections.

Go to the “Output terminals” section in the configuration software.

Here you can choose the terminal which you want to configure. You can make your Contact GSM-16 control the connection to an additional item, in case it is needed.

Page 14: Contact GSM-16 - RITM · terminals on your Contact GSM 5-2, or keypad power terminals (+U, GND), or +12V, GND terminals in your power supply. • If you want to use a resistive hard-wired

www.ritm.ru/en 14

Contact GSM-16. Terminals and Connections.

And you can tune the work of the additional item.

Page 15: Contact GSM-16 - RITM · terminals on your Contact GSM 5-2, or keypad power terminals (+U, GND), or +12V, GND terminals in your power supply. • If you want to use a resistive hard-wired

www.ritm.ru/en 15

Contact GSM-16. Terminals and Connections.

Relay connection

If you want to use a regular Relay, without own configuration, you can configure it in Contact GSM-16, as described on a previous page.

Page 16: Contact GSM-16 - RITM · terminals on your Contact GSM 5-2, or keypad power terminals (+U, GND), or +12V, GND terminals in your power supply. • If you want to use a resistive hard-wired

www.ritm.ru/en 16

Contact GSM-16. Terminals and Connections.

Go to the “Relay” section in the configuration software.

Here you can choose and set-up the output you need.