34
Sampling Conditioning System for Extractive CEMS Continuous Emission Monitoring System From Understanding to Implementation CEMS Sanjeev Rai Perma Pure Jan 18, 2017

Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

  • Upload
    others

  • View
    6

  • Download
    1

Embed Size (px)

Citation preview

Page 1: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

Sampling Conditioning System for Extractive CEMS

Continuous Emission Monitoring SystemFrom Understanding to Implementation

CEMSSanjeev RaiPerma PureJan 18, 2017

Page 2: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

AGENDA

• Different Application Different CEMS

• Importance of sampling system

• Moisture Removal System

• CEMS comparison Germany/China with • CEMS comparison Germany/China with India

• Common CEMS Installation Issues in India

• Maintenance of CEMS system in India

• Portable Conditioning System for Regulator

• Key Points for Regulators

Page 3: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

Different Applications Require Different Approaches to CEMS

• What pollution control systems are now in place?

– FGD? Wet or dry injection?

– SCR? What is ammonia slip level?

– ESP or baghouse? What is particulate level?– ESP or baghouse? What is particulate level?

• What is the fuel source?

– How much sulfur content? (oil, coal)

– Water % by volume? (8-12% normal)

– Trash or other waste (biomass)?

• What is the measurement for?

– Regulation (CEMS)

– Process control

© Perma Pure, 2012 Page 5

Page 4: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

Why Does Pollution Control Matter for CEMS?

1. Pollution control systems require BEFORE and AFTER measurements for process control and verification.

2. Low-level analytes require more accurate analyzers ANDmore accurate sample conditioning systems.

3. Key acid gases are highly water soluble.

– NO2 and SO2

– HCl and Hf

4. Catalysts and reagents can create unintended consequences with downstream reactions.

– E.g., Ammonia Injection

© Perma Pure, 2012 Page 7

Page 5: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

SO2 Solubility in Water100100

9090

8080

7070

6060

5050

So

lub

ilit

y (

cc

SO

So

lub

ilit

y (

cc

SO

22/1

00

ml

H/1

00

ml

H22O

)O

)

© Perma Pure, 2012 Page 5

Temperature (Deg. C)Temperature (Deg. C)

5050

4040

3030

2020

1010

0000 1010 2020 3030 4040 5050 6060 7070 8080 9090 100100

SO

SO

22S

olu

bil

ity (

cc

SO

So

lub

ilit

y (

cc

SO

Page 6: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

ANALYSER SYSTEM

Page 7: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

Importance of Sampling System

• Gas Sample Conditioning Systems is an integral part of the Analyser System. Analyser is as good as it’s Sample.

• Tighter emission norms means more accurate measurement.

• It is legendary within the analyzer community that sampling causes 80% of the process analyser downtime( Clevett, K.J. causes 80% of the process analyser downtime( Clevett, K.J. 1986. Process Analyser Technology.New York: Wiley Science)

• Analyser reliability have improved substantially but the system reliability has not improved much because the sampling system are still the same

Page 8: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

Gas Cooling Characteristic

• Gas cools down from 300 deg C to 30 Deg C in about 120 mm of bare tubing1

• Gas cools down from 300 deg C to 30 Deg C in about 500 mm of insulated tubing1C in about 500 mm of insulated tubing1

• Only way to avoid condensation is to have heated sample line which are properly terminated and do not have cold spots

• 1 Gross and Bundschuh

Page 9: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

Moisture Removal Systems

Condensor

Condensers cool the gas below the dew point, and then remove the condensed liquid water from the gas stream. Water removal is performed automatically to prevent filling the condensate trap and flooding the sampling line.

Permeation Dryer

Permeation dryers are constructed using Nafion®, a material that selectively allows the mass transfer of water vapor from the sample gas through the tube membrane to dry purge gas flowing in an outer tube in the opposite direction.

Page 10: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

About Nafion

• Nafion is a copolymer of Teflon and Sulfonic acid and is highly resistant to chemical attack while selectively permeating water through the membrane.

• Nafion removes water by absorption as water-of-hydration.

• Because this is a specific chemical reaction with water, the process is very selective and gases being dried or processed are usually entirely unaffected.

• The transfer of moisture is driven by the differential water vapor pressure between the membrane sides

Page 11: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

Nafion Permeation Dryers Selectivity

Totally Retained by Nafion®Totally Retained by Nafion®

Atmospheric GasesAtmospheric Gases

HalogensHalogens

HydrocarbonsHydrocarbons

ArAr He HHe H22 NN22 OO22 OO33

BrBr22 ClCl22 FF22 II22Simple forms (alkanes)Simple forms (alkanes)

Inorganic AcidsInorganic Acids

Other OrganicsOther Organics

OxidesOxides

SulfurSulfur

Toxic GasesToxic Gases

HClHCl HF HNOHF HNO33 HH22SOSO44

Aromatics Esters EthersAromatics Esters Ethers

CO COCO CO22 SOSOXX NONOXX

COS HCOS H22S S MercaptansMercaptans

COClCOCl22 HCN HCN NOClNOCl

Typical Combustion Analytes

Nafion.swf

Page 12: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning
Page 13: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

Nafion Dryer Construction

1. Tube and shell design2. Sample is passed through

Nafion tube3. Dry purge gas is passed

through Shellthrough Shell4. The dry Purge gas sweeps

away the moisture through Nafion tube.

5. The sample gas is dried while the purge gas is humidified

Page 14: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning
Page 15: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

CEMS System Comparison with China/Germany and IndiaChina/Germany and India

Page 16: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

CEMS Installation Germany

Page 17: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

CEMS Installation Germany

Heated Sample line is connected to probe without any cold spot and it is installed right upto the cooler inlet

Page 18: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

CEMS Installation China

Page 19: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

CEMS Installation China

Pre SCR installation

Page 20: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

• COMMON CEMS INSTALLATION ISSUES IN INDIAISSUES IN INDIA

Page 21: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

CEMS Installation in India

HEATED PROBE BUT NO HEATED LINE BETWEEN PSHS AND PROBE

Page 22: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

CEMS Installation in India

HEATED SAMPLE LINE HEATED PROBE BUT NEVER POWERED ON SINCE INSTALLATION ( 5 YEARS OLD INSTALLATION)

Page 23: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

CEMS Installation in India

HEATED PROBE HEATED LINE BUT NOT PROPERLY TERMINATED

Page 24: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

CEMS Installation in India

Non Heated Line Installed Between Probe to blowback

Page 25: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

CEMS Installation in India

Condensate Pot Installed Between Blowback and Analyser

Page 26: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

CEMS Installation in India

CONDENSATION IN THE SAMPLE LINE INSDE ANALYSER ABINET

Page 27: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

CEMS Installation in India

No Heated Sample Line upto the cooler

Page 28: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

CEMS Installation in India

Perisaltic pump was regularly failing so they iremoved pump and installed autodrain system

Page 29: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

CEMS Installation in India

NO HEATED SAMPLE LINE BEFORE NAFION DRYER

Page 30: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

Nafion System Installation

Page 31: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

Portable Sample Conditioning System for Onsite Testing

Page 32: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

Key Points for Regulator

How to ensure measurement accuracy

Measurement accuracy is more affected by sampling system than by analyzer

Moisture to be removed only in cooler or in Nafion Moisture to be removed only in cooler or in NafionDryer

All the component in the sampling system before moisture separation should be heated, no cold spot

No Condensate Pot/ moisture trap to be present in sampling system

Page 33: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

Key Point for Regulator

CEMS is a system and not merely an instrument , if any component of system is not installed as per the best practice the accuracy will get compromised or system will fail much before the useful life.

As permitted levels of Sox and NOx are continually being reduced, it is even important to consider right conditioning technology to get representative sample.

During inspection it is important to look the complete system from probe to analyzer.

Page 34: Continuous Emission Monitoring System From Understanding ...cdn.cseindia.org/userfiles/sample-conditioning-system.pdf · Importance of Sampling System • Gas Sample Conditioning

Thank You

Sanjeev Rai Sanjeev Rai [email protected]

Mobile:+919910098244